101
|
Tee YK, Khrapitchev AA, Sibson NR, Payne SJ, Chappell MA. Optimal sampling schedule for chemical exchange saturation transfer. Magn Reson Med 2013; 70:1251-62. [PMID: 23315799 DOI: 10.1002/mrm.24567] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2012] [Revised: 10/02/2012] [Accepted: 10/29/2012] [Indexed: 12/27/2022]
Abstract
The sampling schedule for chemical exchange saturation transfer imaging is normally uniformly distributed across the saturation frequency offsets. When this kind of evenly distributed sampling schedule is used to quantify the chemical exchange saturation transfer effect using model-based analysis, some of the collected data are minimally informative to the parameters of interest. For example, changes in labile proton exchange rate and concentration mainly affect the magnetization near the resonance frequency of the labile pool. In this study, an optimal sampling schedule was designed for a more accurate quantification of amine proton exchange rate and concentration, and water center frequency shift based on an algorithm previously applied to magnetization transfer and arterial spin labeling. The resulting optimal sampling schedule samples repeatedly around the resonance frequency of the amine pool and also near to the water resonance to maximize the information present within the data for quantitative model-based analysis. Simulation and experimental results on tissue-like phantoms showed that greater accuracy and precision (>30% and >46%, respectively, for some cases) were achieved in the parameters of interest when using optimal sampling schedule compared with evenly distributed sampling schedule. Hence, the proposed optimal sampling schedule could replace evenly distributed sampling schedule in chemical exchange saturation transfer imaging to improve the quantification of the chemical exchange saturation transfer effect and parameter estimation.
Collapse
Affiliation(s)
- Y K Tee
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, UK; Department of Engineering Science, Institute of Biomedical Engineering, Centre for Doctoral Training in Healthcare Innovation, University of Oxford, UK
| | | | | | | | | |
Collapse
|
102
|
Zhao X, Wen Z, Zhang G, Huang F, Lu S, Wang X, Hu S, Chen M, Zhou J. Three-dimensional turbo-spin-echo amide proton transfer MR imaging at 3-Tesla and its application to high-grade human brain tumors. Mol Imaging Biol 2013; 15:114-22. [PMID: 22644987 DOI: 10.1007/s11307-012-0563-1] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE Amide proton transfer (APT) imaging is able to extend the achievable magnetic resonance imaging (MRI) contrast to the protein level. In this study, we demonstrate the feasibility of applying a turbo-spin-echo (TSE)-based, three-dimensional (3D) APT sequence into routine clinical practice for patients with brain tumors. PROCEDURES Experiments were performed on a Philips 3-Tesla (3-T) MRI scanner using an eight-channel phased-array coil for reception. A fast 3D APT sequence with a TSE acquisition was proposed (saturation power, 2 μT; saturation time, 500 ms; 8 slices). The gradient echo (GRE)-based field-mapping technique or water-saturation-shift-referencing (WASSR) technique was used to acquire B(0) maps to correct for B(0)-induced artifacts in APT images. The test was performed on a box of homogenous protein solution, four healthy volunteers, and eight patients with high-grade gliomas. RESULTS The experimental data from a homogenous, protein-containing phantom and healthy volunteers show that the sequence produced a uniform contrast across all slices. The average MTR(asym)(3.5 ppm) values with GRE B(0)-corrected 3D APT imaging and WASSR-corrected 3D APT imaging were both comparable to the values obtained using the undemanding single-slice acquisition. The average APT image intensity was consistently higher in the tumor core than in the peripheral edema and in the contralateral normal-appearing white matter (both P < 0.001). CONCLUSION 3D APT imaging of brain tumors can be performed in about 5 min at 3-T using a routine, commercial eight-channel SENSE coil.
Collapse
|
103
|
Hectors SJCG, Jacobs I, Strijkers GJ, Nicolay K. Amide proton transfer imaging of high intensity focused ultrasound-treated tumor tissue. Magn Reson Med 2013; 72:1113-22. [PMID: 24154945 DOI: 10.1002/mrm.25000] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2013] [Revised: 09/11/2013] [Accepted: 09/24/2013] [Indexed: 11/08/2022]
Abstract
PURPOSE In this study, the suitability of amide proton transfer (APT) imaging as a biomarker for the characterization of high intensity focused ultrasound (HIFU)-treated tumor tissue was assessed. METHODS APT imaging was performed on tumor-bearing mice before (n = 15), directly after (n = 15) and at 3 days (n = 8) after HIFU treatment. A control group (n = 7) of nontreated animals was scanned at the same time points. Histogram analysis of the tumor APT-weighted signal distributions was performed to assess HIFU-induced changes in the tumor APT contrast. RESULTS Distinct regions of decreased APT-weighted signal were observed at both time points after HIFU treatment. Analysis of the tumor APT-weighted signal distribution showed a pronounced shift toward lower APT-weighted signal values after HIFU treatment. A significantly increased fraction of pixels with an APT-weighted signal value between -10 and -2% was observed both directly (0.37 ± 0.16) and at 3 days (0.49 ± 0.16) after HIFU treatment as compared to baseline (0.22 ± 0.16). CONCLUSION The presented results show that APT imaging is sensitive to HIFU-induced changes in tumor tissue and may thus serve as a new biomarker for monitoring the response of tumor tissue to HIFU treatment.
Collapse
Affiliation(s)
- Stefanie J C G Hectors
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Center for Imaging Research and Education (CIRE), Eindhoven, The Netherlands
| | | | | | | |
Collapse
|
104
|
Liu G, Song X, Chan KWY, McMahon MT. Nuts and bolts of chemical exchange saturation transfer MRI. NMR IN BIOMEDICINE 2013; 26:810-28. [PMID: 23303716 PMCID: PMC4144273 DOI: 10.1002/nbm.2899] [Citation(s) in RCA: 233] [Impact Index Per Article: 21.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2012] [Revised: 10/23/2012] [Accepted: 11/01/2012] [Indexed: 05/03/2023]
Abstract
Chemical exchange saturation transfer (CEST) has emerged as a novel MRI contrast mechanism that is well suited for molecular imaging studies. This new mechanism can be used to detect small amounts of contrast agent through the saturation of rapidly exchanging protons on these agents, allowing a wide range of applications. CEST technology has a number of indispensable features, such as the possibility of simultaneous detection of multiple 'colors' of agents and of changes in their environment (e.g. pH, metabolites, etc.) through MR contrast. Currently, a large number of new imaging schemes and techniques are being developed to improve the temporal resolution and specificity and to correct for the influence of B0 and B1 inhomogeneities. In this review, the techniques developed over the last decade are summarized with the different imaging strategies and post-processing methods discussed from a practical point of view, including the description of their relative merits for the detection of CEST agents. The goal of the present work is to provide the reader with a fundamental understanding of the techniques developed, and to provide guidance to help refine future applications of this technology. This review is organized into three main sections ('Basics of CEST contrast', 'Implementation' and 'Post-processing'), and also includes a brief Introduction and Summary. The 'Basics of CEST contrast' section contains a description of the relevant background theory for saturation transfer and frequency-labeled transfer, and a brief discussion of methods to determine exchange rates. The 'Implementation' section contains a description of the practical considerations in conducting CEST MRI studies, including the choice of magnetic field, pulse sequence, saturation pulse, imaging scheme, and strategies to separate magnetization transfer and CEST. The 'Post-processing' section contains a description of the typical image processing employed for B0 /B1 correction, Z-spectral interpolation, frequency-selective detection and improvement of CEST contrast maps.
Collapse
Affiliation(s)
- Guanshu Liu
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | | | | | | |
Collapse
|
105
|
Dula AN, Arlinghaus LR, Dortch RD, Dewey BE, Whisenant JG, Ayers GD, Yankeelov TE, Smith SA. Amide proton transfer imaging of the breast at 3 T: establishing reproducibility and possible feasibility assessing chemotherapy response. Magn Reson Med 2013; 70:216-24. [PMID: 22907893 PMCID: PMC3505231 DOI: 10.1002/mrm.24450] [Citation(s) in RCA: 132] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2012] [Revised: 06/06/2012] [Accepted: 07/11/2012] [Indexed: 12/20/2022]
Abstract
Chemical exchange saturation transfer imaging can generate contrast that is sensitive to amide protons associated with proteins and peptides (termed amide proton transfer, APT). In breast cancer, APT contrast may report on underlying changes in microstructural tissue composition. However, to date, there have been no developments or applications of APT chemical exchange saturation transfer to breast cancer. As a result, the aims of this study were to (i) experimentally explore optimal scan parameters for breast chemical exchange saturation transfer near the amide resonance at 3 T, (ii) establish the reliability of APT imaging of healthy fibroglandular tissue, and (iii) demonstrate preliminary results on APT changes in locally advanced breast cancer observed during the course of neoadjuvant chemotherapy. Chemical exchange saturation transfer measurements were experimentally optimized on cross-linked bovine serum albumin phantoms, and the reliability of APT imaging was assessed in 10 women with no history of breast disease. The mean difference between test-retest APT values was not significantly different from zero, and the individual difference values were not dependent on the average APT value. The 95% confidence interval limits were ±0.70% (α = 0.05), and the repeatability was 1.91. APT measurements were also performed in three women before and after one cycle of chemotherapy. Following therapy, APT increased in the one patient with progressive disease and decreased in the two patients with a partial or complete response. Together, these results suggest that APT imaging may report on treatment response in these patients.
Collapse
Affiliation(s)
- Adrienne N Dula
- Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232-2310, USA
| | | | | | | | | | | | | | | |
Collapse
|
106
|
Proceedings for OctoberCEST, the third international workshop on CEST imaging, 15-17 October 2012. CONTRAST MEDIA & MOLECULAR IMAGING 2013. [DOI: 10.1002/cmmi.1522] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
107
|
Vinogradov E, Sherry AD, Lenkinski RE. CEST: from basic principles to applications, challenges and opportunities. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2013; 229:155-72. [PMID: 23273841 PMCID: PMC3602140 DOI: 10.1016/j.jmr.2012.11.024] [Citation(s) in RCA: 229] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2012] [Revised: 11/18/2012] [Accepted: 11/20/2012] [Indexed: 05/03/2023]
Abstract
Chemical Exchange Saturation Transfer (CEST) offers a new type of contrast for MRI that is molecule specific. In this approach, a slowly exchanging NMR active nucleus, typically a proton, possessing a chemical shift distinct from water is selectively saturated and the saturated spin is transferred to the bulk water via chemical exchange. Many molecules can act as CEST agents, both naturally occurring endogenous molecules and new types of exogenous agents. A large variety of molecules have been demonstrated as potential agents, including small diamagnetic molecules, complexes of paramagnetic ions, endogenous macromolecules, dendrimers and liposomes. In this review we described the basic principles of the CEST experiment, with emphasis on the similarity to earlier saturation transfer experiments described in the literature. Interest in quantitative CEST has also resulted in the development of new exchange-sensitive detection schemes. Some emerging clinical applications of CEST are described and the challenges and opportunities associated with translation of these methods to the clinical environment are discussed.
Collapse
Affiliation(s)
- Elena Vinogradov
- Department of Radiology and Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, USA.
| | | | | |
Collapse
|
108
|
Zhou J, Zhu H, Lim M, Blair L, Quinones-Hinojosa A, Messina SA, Eberhart CG, Pomper MG, Laterra J, Barker PB, van Zijl PCM, Blakeley JO. Three-dimensional amide proton transfer MR imaging of gliomas: Initial experience and comparison with gadolinium enhancement. J Magn Reson Imaging 2013; 38:1119-28. [PMID: 23440878 DOI: 10.1002/jmri.24067] [Citation(s) in RCA: 158] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2012] [Accepted: 01/10/2013] [Indexed: 01/31/2023] Open
Abstract
PURPOSE To investigate the feasibility of a three-dimensional amide-proton-transfer (APT) imaging sequence with gradient- and spin-echo readouts at 3 Tesla in patients with high- or low-grade gliomas. MATERIALS AND METHODS Fourteen patients with newly diagnosed gliomas were recruited. After B0 inhomogeneity correction on a voxel-by-voxel basis, APT-weighted images were reconstructed using a magnetization-transfer-ratio asymmetry at offsets of ±3.5 ppm with respect to the water resonance. Analysis of variance post hoc tests were used for statistical evaluations, and results were validated with pathology. RESULTS In six patients with gadolinium-enhancing high-grade gliomas, enhancing tumors on the postcontrast T1 -weighted images were consistently hyperintense on the APT-weighted images. Increased APT-weighted signal intensity was also clearly visible in two pathologically proven, high-grade gliomas without gadolinium enhancement. The average APT-weighted signal was significantly higher in the lesions than in the contralateral normal-appearing brain tissue (P < 0.001). In six low-grade gliomas, including two with gadolinium enhancement, APT-weighted imaging showed iso-intensity or mild punctate hyperintensity within all the lesions, which was significantly lower than that seen in the high-grade gliomas (P < 0.001). CONCLUSION The proposed three-dimensional APT imaging sequence can be incorporated into standard brain MRI protocols for patients with malignant gliomas.
Collapse
Affiliation(s)
- Jinyuan Zhou
- Department of Radiology, Johns Hopkins University, Baltimore, Maryland, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
109
|
Early postsurgical visualization of composite mesh used in ventral hernia repair by amide proton transfer MRI. Magn Reson Med 2013; 71:313-7. [DOI: 10.1002/mrm.24666] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2012] [Revised: 12/20/2012] [Accepted: 01/09/2013] [Indexed: 12/20/2022]
|
110
|
Yadav NN, Jones CK, Hua J, Xu J, van Zijl PCM. Imaging of endogenous exchangeable proton signals in the human brain using frequency labeled exchange transfer imaging. Magn Reson Med 2013; 69:966-73. [PMID: 23400954 DOI: 10.1002/mrm.24655] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2012] [Revised: 12/28/2012] [Accepted: 12/31/2012] [Indexed: 01/01/2023]
Abstract
PURPOSE To image endogenous exchangeable proton signals in the human brain using a recently reported method called frequency labeled exchange transfer (FLEX) MRI. METHODS As opposed to labeling exchangeable protons using saturation (i.e., chemical exchange saturation transfer, or CEST), FLEX labels exchangeable protons with their chemical shift evolution. The use of short high-power frequency pulses allows more efficient labeling of rapidly exchanging protons, while time domain acquisition allows removal of contamination from semi-solid magnetization transfer effects. RESULTS FLEX-based exchangeable proton signals were detected in human brain over the 1-5 ppm frequency range from water. Conventional magnetization transfer contrast and the bulk water signal did not interfere in the FLEX spectrum. The information content of these signals differed from in vivo CEST data in that the average exchange rate of these signals was 350-400 s(-1) , much faster than the amide signal usually detected using direct saturation (∼30 s(-1) ). Similarly, fast exchanging protons could be detected in egg white in the same frequency range where amide and amine protons of mobile proteins and peptides are known to resonate. CONCLUSIONS FLEX MRI in the human brain preferentially detects more rapidly exchanging amide/amine protons compared to traditional CEST experiments, thereby changing the information content of the exchangeable proton spectrum. This has the potential to open up different types of endogenous applications as well as more easy detection of rapidly exchanging protons in diaCEST agents or fast exchanging units such as water molecules in paracest agents without interference of conventional magnetization transfer contrast.
Collapse
Affiliation(s)
- Nirbhay N Yadav
- Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | | | | | | | | |
Collapse
|
111
|
Jinyuan ZHOU, Xiaohua HONG. Molecular Imaging Using Endogenous Cellular Proteins. BO PU XUE ZA ZHI = CHINESE JOURNAL OF MICROWAVE & RADIO-FREQUENCY SPECTROSCOPY 2013; 30:307-321. [PMID: 25267882 PMCID: PMC4176899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Amide proton transfer (APT) imaging is a novel molecular MRI technique that generates image contrast based on endogenous cellular proteins in tissue. Theoretically, the APT-MRI signal depends primarily on the mobile amide proton concentration and amide proton exchange rates (which are related to tissue pH). The APT technique has been used for non-invasive pH imaging in stroke (where pH drops) and protein content imaging in tumor (where many proteins are overexpressed). Notably, it has been recently demonstrated in animal models that the APT-MRI signal is a unique imaging biomarker to distinguish between radiation necrosis and active tumor. In this paper, we will briefly introduce the basic principle of APT imaging and review its current successful applications for the imaging of stroke and the imaging of brain tumors in animal models and in patients.
Collapse
Affiliation(s)
- ZHOU Jinyuan
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, MD 21287, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD 21205, USA
| | - HONG Xiaohua
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, MD 21287, USA
- Department of Oncology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430020, China
| |
Collapse
|
112
|
Chan KWY, McMahon MT, Kato Y, Liu G, Bulte JWM, Bhujwalla ZM, Artemov D, van Zijl PCM. Natural D-glucose as a biodegradable MRI contrast agent for detecting cancer. Magn Reson Med 2012; 68:1764-73. [PMID: 23074027 DOI: 10.1002/mrm.24520] [Citation(s) in RCA: 272] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2012] [Revised: 09/13/2012] [Accepted: 09/17/2012] [Indexed: 12/13/2022]
Abstract
PURPOSE Modern imaging technologies such as CT, PET, SPECT, and MRI employ contrast agents to visualize the tumor microenvironment, providing information on malignancy and response to treatment. Currently, all clinical imaging agents require chemical labeling, i.e. with iodine (CT), radioisotopes (PET/SPECT), or paramagnetic metals (MRI). The goal was to explore the possibility of using simple D-glucose as an infusable biodegradable MRI agent for cancer detection. METHODS D-glucose signals were detected using chemical exchange saturation transfer (glucoCEST) MRI of its hydroxyl groups. Feasibility was established in phantoms as well as in vivo using two human breast cancer cell lines, MDA-MB-231 and MCF-7, implanted orthotopically in nude mice. PET and contrast-enhanced MRI were also acquired. RESULTS Both tumor types exhibited significant glucoCEST signal enhancement during systemic sugar infusion (mild hyperglycemia), allowing their noninvasive visualization. GlucoCEST showed differences between types, while PET and CE-MRI did not. Data are discussed in terms of signal contributions from the increased vascular volume in tumors and especially from the acidic extracellular extravascular space (EES), where glucoCEST signal is expected to be enhanced due to a slow down of hydroxyl proton exchange. CONCLUSIONS This observation opens up the possibility for using simple non-toxic sugars as contrast agents for cancer detection with MRI by employing hydroxyl protons as a natural label.
Collapse
Affiliation(s)
- Kannie W Y Chan
- Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, USA
| | | | | | | | | | | | | | | |
Collapse
|
113
|
Tee YK, Khrapitchev AA, Sibson NR, Payne SJ, Chappell MA. Evaluating the use of a continuous approximation for model-based quantification of pulsed chemical exchange saturation transfer (CEST). JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2012; 222:88-95. [PMID: 22858666 PMCID: PMC3431007 DOI: 10.1016/j.jmr.2012.07.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2012] [Revised: 06/30/2012] [Accepted: 07/03/2012] [Indexed: 05/08/2023]
Abstract
Many potential clinical applications of chemical exchange saturation transfer (CEST) have been studied in recent years. However, due to various limitations such as specific absorption rate guidelines and scanner hardware constraints, most of the proposed applications have yet to be translated into routine diagnostic tools. Currently, pulsed CEST which uses multiple short pulses to perform the saturation is the only viable irradiation scheme for clinical translation. However, performing quantitative model-based analysis on pulsed CEST is time consuming because it is necessary to account for the time dependent amplitude of the saturation pulses. As a result, pulsed CEST is generally treated as continuous CEST by finding its equivalent average field or power. Nevertheless, theoretical analysis and simulations reveal that the resulting magnetization is different when the different irradiation schemes are applied. In this study, the quantification of important model parameters such as the amine proton exchange rate from a pulsed CEST experiment using quantitative model-based analyses were examined. Two model-based approaches were considered - discretized and continuous approximation to the time dependent RF irradiation pulses. The results showed that the discretized method was able to fit the experimental data substantially better than its continuous counterpart, but the smaller fitted error of the former did not translate to significantly better fit for the important model parameters. For quantification of the endogenous CEST effect, such as in amide proton transfer imaging, a model-based approach using the average power equivalent saturation can thus be used in place of the discretized approximation.
Collapse
Affiliation(s)
- Y K Tee
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, UK.
| | | | | | | | | |
Collapse
|
114
|
Zu Z, Janve VA, Xu J, Does MD, Gore JC, Gochberg DF. A new method for detecting exchanging amide protons using chemical exchange rotation transfer. Magn Reson Med 2012; 69:637-47. [PMID: 22505325 DOI: 10.1002/mrm.24284] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2011] [Revised: 03/13/2012] [Accepted: 03/14/2012] [Indexed: 11/08/2022]
Abstract
In this study, we introduce a new method for amide proton transfer imaging based on chemical exchange rotation transfer. It avoids several artifacts that plague conventional chemical exchange saturation transfer approaches by creating label and reference scans based on varying the irradiation pulse rotation angle (π and 2π radians) instead of the frequency offset (3.5 and -3.5 ppm). Specifically, conventional analysis is sensitive to confounding contributions from magnetic field (B(0)) inhomogeneities and, more problematically, inherently asymmetric macromolecular resonances. In addition, the lipid resonance at -3.5 ppm complicates the interpretation of the reference scan and decreases the resulting contrast. Finally, partial overlap of the amide signal by nearby amines and hydroxyls obscure the results. By avoiding these issues, our new method is a promising approach for imaging endogenous protein and peptide content and mapping pH.
Collapse
Affiliation(s)
- Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232-2310, USA
| | | | | | | | | | | |
Collapse
|
115
|
Zu Z, Janve VA, Li K, Does MD, Gore JC, Gochberg DF. Multi-angle ratiometric approach to measure chemical exchange in amide proton transfer imaging. Magn Reson Med 2011; 68:711-9. [PMID: 22161770 DOI: 10.1002/mrm.23276] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2011] [Revised: 09/18/2011] [Accepted: 10/09/2011] [Indexed: 12/27/2022]
Abstract
Amide proton transfer imaging, a specific form of chemical exchange saturation transfer imaging, has previously been applied to studies of acute ischemic acidosis, stroke, and cancer. However, interpreting the resulting contrast is complicated by its dependence on the exchange rate between amides and water, the amide concentration, amide and water relaxation, and macromolecular magnetization transfer. Hence, conventional chemical exchange saturation transfer contrast is not specific to changes such as reductions in pH due to tissue acidosis. In this article, a multi-angle ratiometric approach based on several pulsed-chemical exchange saturation transfer scans at different irradiation flip angles is proposed to specifically reflect exchange rates only. This separation of exchange effects in pulsed-chemical exchange saturation transfer experiments is based on isolating rotation vs. saturation contributions, and such methods form a new subclass of chemical exchange rotation transfer (CERT) experiments. Simulations and measurements of creatine/agar phantoms indicate that a newly proposed imaging metric isolates the effects of exchange rate changes, independent of other sample parameters.
Collapse
Affiliation(s)
- Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA
| | | | | | | | | | | |
Collapse
|
116
|
Jones CK, Polders D, Hua J, Zhu H, Hoogduin HJ, Zhou J, Luijten P, van Zijl PCM. In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7 T. Magn Reson Med 2011; 67:1579-89. [PMID: 22083645 DOI: 10.1002/mrm.23141] [Citation(s) in RCA: 168] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2011] [Revised: 06/29/2011] [Accepted: 07/18/2011] [Indexed: 12/27/2022]
Abstract
Chemical exchange saturation transfer (CEST) is a technique to indirectly detect pools of exchangeable protons through the water signal. To increase its applicability to human studies, it is needed to develop sensitive pulse sequences for rapidly acquiring whole-organ images while adhering to stringent amplifier duty cycle limitations and specific absorption rate restrictions. In addition, the interfering effects of direct water saturation and conventional magnetization transfer contrast complicate CEST quantification and need to be reduced as much as possible. It is shown that for protons exchanging with rates of less than 50-100 Hz, such as imaged in amide proton transfer experiments, these problems can be addressed by using a three-dimensional steady state pulsed acquisition of limited B(1) strength (≈ 1 μT). Such an approach exploits the fact that the direct water saturation width, magnetization transfer contrast magnitude, and specific absorption rate increase strongly with B(1) , while the size of the CEST effect for such protons depends minimally on B(1) . A short repetition time (65 ms) steady-state sequence consisting of a brief saturation pulse (25 ms) and a segmented echo-planar imaging train allowed acquisition of a three-dimensional whole-brain volume in approximately 11 s per saturation frequency, while remaining well within specific absorption rate and duty cycle limits. Magnetization transfer contrast was strongly reduced, but substantial saturation effects were found at frequencies upfield from water, which still confound the use of magnetization transfer asymmetry analysis. Fortunately, the limited width of the direct water saturation signal could be exploited to fit it with a Lorentzian function allowing CEST quantification. Amide proton transfer effects ranged between 1.5% and 2.5% in selected white and grey matter regions. This power and time-efficient 3D pulsed CEST acquisition scheme should aid endogenous CEST quantification at both high and low fields.
Collapse
Affiliation(s)
- Craig K Jones
- Division of MR Research, Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
| | | | | | | | | | | | | | | |
Collapse
|
117
|
Kim M, Chan Q, Anthony MP, Cheung KMC, Samartzis D, Khong PL. Assessment of glycosaminoglycan distribution in human lumbar intervertebral discs using chemical exchange saturation transfer at 3 T: feasibility and initial experience. NMR IN BIOMEDICINE 2011; 24:1137-1144. [PMID: 21387446 DOI: 10.1002/nbm.1671] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2010] [Revised: 12/10/2010] [Accepted: 12/11/2010] [Indexed: 05/30/2023]
Abstract
Recent studies have proposed that glycosaminoglycan chemical exchange saturation transfer (gagCEST) is associated with a loss of glycosaminoglycans (GAGs), which may be an initiating factor in intervertebral disc (IVD) degeneration. Despite its promising potential, this application has not been reported in human in vivo IVD studies because of the challenges of B(0) magnetic field inhomogeneity in gagCEST. This study aimed to evaluate the feasibility of quantifying CEST values in IVDs of healthy volunteers using a clinical 3 T scanner. A single-slice turbo spin echo sequence was used to quantify the CEST effect in various GAG phantoms and in IVDs of 12 volunteers. The phantom results indicated high correlation between gagCEST and GAG concentrations (R(2) = 0.95). With optimal B(0) inhomogeneity correction, in vivo CEST maps of IVDs showed robust contrast between the nucleus pulposus (NP) and the annulus fibrosus (AF) (p < 0.01), as well as higher signal in the central relative to the peripheral NP. In addition, a trend of decreasing CEST values from upper to lower disc levels was evident in NP. Our results demonstrate that in vivo gagCEST quantification in human lumbar IVDs is feasible at 3 T in combination with successful B(0) inhomogeneity correction, but without significant hardware modifications. Our initial findings suggest that it would be worthwhile to perform direct correlation studies between CEST and GAGs using cadaver samples, and to extend this novel technique to studies on patients with degenerative discs to better understand its distinct imaging features relative to conventional techniques.
Collapse
Affiliation(s)
- Mina Kim
- Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong.
| | | | | | | | | | | |
Collapse
|
118
|
Current World Literature. Curr Opin Neurol 2011; 24:409-13. [DOI: 10.1097/wco.0b013e3283499d51] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
119
|
Zaiss M, Schmitt B, Bachert P. Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2011; 211:149-55. [PMID: 21641247 DOI: 10.1016/j.jmr.2011.05.001] [Citation(s) in RCA: 215] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2011] [Revised: 04/26/2011] [Accepted: 05/09/2011] [Indexed: 05/24/2023]
Abstract
Chemical exchange saturation transfer (CEST) processes in aqueous systems are quantified by evaluation of z-spectra, which are obtained by acquisition of the water proton signal after selective RF presaturation at different frequencies. When saturation experiments are performed in vivo, three effects are contributing: CEST, direct water saturation (spillover), and magnetization transfer (MT) mediated by protons bound to macromolecules and bulk water molecules. To analyze the combined saturation a new analytical model is introduced which is based on the weak-saturation-pulse (WSP) approximation. The model combines three single WSP approaches to a general model function. Simulations demonstrated the benefits and constraints of the model, in particular the capability of the model to reproduce the ideal proton transfer rate (PTR) and the conventional MT rate for moderate spillover effects (up to 50% direct saturation at CEST-resonant irradiation). The method offers access to PTR from z-spectra data without further knowledge of the system, but requires precise measurements with dense saturation frequency sampling of z-spectra. PTR is related to physical parameters such as concentration, transfer rates and thereby pH or temperature of tissue, using either exogenous contrast agents (PARACEST, DIACEST) or endogenous agents such as amide protons and -OH protons of small metabolites.
Collapse
Affiliation(s)
- Moritz Zaiss
- Department of Medical Physics in Radiology, Deutsches Krebsforschungszentrum (DKFZ, German Cancer Research Center), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany.
| | | | | |
Collapse
|
120
|
van Zijl PCM, Yadav NN. Chemical exchange saturation transfer (CEST): what is in a name and what isn't? Magn Reson Med 2011; 65:927-48. [PMID: 21337419 PMCID: PMC3148076 DOI: 10.1002/mrm.22761] [Citation(s) in RCA: 799] [Impact Index Per Article: 61.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2010] [Revised: 11/01/2010] [Accepted: 11/24/2010] [Indexed: 12/24/2022]
Abstract
Chemical exchange saturation transfer (CEST) imaging is a relatively new magnetic resonance imaging contrast approach in which exogenous or endogenous compounds containing either exchangeable protons or exchangeable molecules are selectively saturated and after transfer of this saturation, detected indirectly through the water signal with enhanced sensitivity. The focus of this review is on basic magnetic resonance principles underlying CEST and similarities to and differences with conventional magnetization transfer contrast. In CEST magnetic resonance imaging, transfer of magnetization is studied in mobile compounds instead of semisolids. Similar to magnetization transfer contrast, CEST has contributions of both chemical exchange and dipolar cross-relaxation, but the latter can often be neglected if exchange is fast. Contrary to magnetization transfer contrast, CEST imaging requires sufficiently slow exchange on the magnetic resonance time scale to allow selective irradiation of the protons of interest. As a consequence, magnetic labeling is not limited to radio-frequency saturation but can be expanded with slower frequency-selective approaches such as inversion, gradient dephasing and frequency labeling. The basic theory, design criteria, and experimental issues for exchange transfer imaging are discussed. A new classification for CEST agents based on exchange type is proposed. The potential of this young field is discussed, especially with respect to in vivo application and translation to humans.
Collapse
Affiliation(s)
- Peter C M van Zijl
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, USA.
| | | |
Collapse
|
121
|
Schmitt B, Zbýn S, Stelzeneder D, Jellus V, Paul D, Lauer L, Bachert P, Trattnig S. Cartilage quality assessment by using glycosaminoglycan chemical exchange saturation transfer and (23)Na MR imaging at 7 T. Radiology 2011; 260:257-64. [PMID: 21460030 DOI: 10.1148/radiol.11101841] [Citation(s) in RCA: 163] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE To compare a glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging method, which enables sampling of the water signal as a function of the presaturation offset (z-spectrum) at 13 points in clinically feasible imaging times, with sodium 23 ((23)Na) magnetic resonance (MR) imaging in patients after cartilage repair surgery (matrix-associated autologous chondrocyte transplantation and microfracture therapy). MATERIALS AND METHODS One female patient (67.3 years), and 11 male patients (median age, 28.8 years; interquartile range [IQR], 24.6-32.3 years) were examined with a 7-T whole-body system, with approval of the local ethics committee after written informed consent was obtained. A modified three-dimensional gradient-echo sequence and a 28-channel knee coil were used for gagCEST imaging. (23)Na imaging was performed with a circularly polarized knee coil by using a modified gradient-echo sequence. Statistical analysis of differences and Spearman correlation were applied. RESULTS The median of asymmetries in gagCEST z-spectra summed over all offsets from 0 to 1.3 ppm was 7.99% (IQR, 6.33%-8.79%) in native cartilage and 5.13% (IQR, 2.64%-6.34%) in repair tissue. A strong correlation (r = 0.701; 95% confidence interval: 0.21, 0.91) was found between ratios of signal intensity from native cartilage to signal intensity from repair tissue obtained with gagCEST or (23)Na imaging. The median of dimensionless ratios between native cartilage and repair tissue was 1.28 (IQR, 1.20-1.58) for gagCEST and 1.26 (IQR, 1.21-1.48) for (23)Na MR imaging. CONCLUSION The high correlation between the introduced gagCEST method and (23)Na imaging implies that gagCEST is a potentially useful biomarker for glycosaminoglycans.
Collapse
Affiliation(s)
- Benjamin Schmitt
- Division of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
122
|
Zhao X, Wen Z, Huang F, Lu S, Wang X, Hu S, Zu D, Zhou J. Saturation power dependence of amide proton transfer image contrasts in human brain tumors and strokes at 3 T. Magn Reson Med 2011; 66:1033-41. [PMID: 21394783 DOI: 10.1002/mrm.22891] [Citation(s) in RCA: 128] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2010] [Revised: 01/29/2011] [Accepted: 01/31/2011] [Indexed: 11/10/2022]
Abstract
Amide proton transfer (APT) imaging is capable of detecting mobile cellular proteins and peptides in tumor and monitoring pH effects in stroke, through the saturation transfer between irradiated amide protons and water protons. In this work, four healthy subjects, eight brain tumor patients (four with high-grade glioma, one with lung cancer metastasis, and three with meningioma), and four stroke patients (average 4.3 ± 2.5 days after the onset of the stroke) were scanned at 3 T, using different radiofrequency saturation powers. The APT effect was quantified using the magnetization transfer ratio (MTR) asymmetry at 3.5 ppm with respect to the water resonance. At a saturation power of 2 μT, the measured APT-MRI signal of the normal brain tissue was almost zero, due to the contamination of the negative conventional magnetization transfer ratio asymmetry. This irradiation power caused an optimal hyperintense APT-MRI signal in the tumor and an optimal hypointense signal in the stroke, compared to the normal brain tissue. The results suggest that the saturation power of 2 μT is ideal for APT imaging of these two pathologies at 3 T with the existing clinical hardware.
Collapse
|
123
|
Schmitt B, Zaiß M, Zhou J, Bachert P. Optimization of pulse train presaturation for CEST imaging in clinical scanners. Magn Reson Med 2011; 65:1620-9. [DOI: 10.1002/mrm.22750] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2010] [Revised: 10/07/2010] [Accepted: 11/17/2010] [Indexed: 12/27/2022]
|