101
|
Lo CT, Wu YS, Huang SM, Tsai PJ, Lee CL. Carbon fibre-supported hierarchical NiCo layered double hydroxide nanosheets as non-enzymatic glucose sensors for sport drinks and serum. Food Chem 2022; 383:132383. [DOI: 10.1016/j.foodchem.2022.132383] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 02/01/2022] [Accepted: 02/05/2022] [Indexed: 01/03/2023]
|
102
|
Voltammetric Detection of Glucose-The Electrochemical Behavior of the Copper Oxide Materials with Well-Defined Facets. SENSORS 2022; 22:s22134783. [PMID: 35808280 PMCID: PMC9269370 DOI: 10.3390/s22134783] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 06/21/2022] [Accepted: 06/22/2022] [Indexed: 02/04/2023]
Abstract
Cu2O nanomaterials with well-defined facets and uniform size were synthesized by a wet-chemical method. Regardless of the additive composition, powders crystallize mostly in cuprite form. To compare their electrochemical behavior, the obtained materials were deposited on carbon glassy electrodes. The response to glucose from the materials with different exposed facets was recorded with a delay at the anodic curve. The chronoamperometric analyses (AMP) exhibited a lower signal in contrast to the cyclic voltammetry data (CV), indicating that the number of active sites involved in glucose oxidation processes resulting from the structure of the material is insufficient. For samples with dominant (100) or (111) planes, a typical characteristic was observed, however, with an additional peak at the anodic curve. The location of the peaks is approximately the same and no significant differences from the AMP and CV analysis were observed. The sample enclosed by the (111) facets exhibited higher activity; however, as a result of the redox reaction with glucose molecules, the surface state is changing. Cu2O materials enclosed by (100) planes exhibited optimal sensitivity as well as a large detective range. Samples with differential facet exposition present various current-potential profiles, as the effect of binder-particle interaction with Nafion.
Collapse
|
103
|
Rabbani SS, Nisar A, Zafar A, Liu Y, Sun H, Karim S, Hussain S, Shah AU, Hussain SZ, Mehboob N, Yu Y, Ahmad M. Mesoporous NiCo 2S 4nanoflakes as an efficient and durable electrocatalyst for non-enzymatic detection of cholesterol. NANOTECHNOLOGY 2022; 33:375502. [PMID: 35749132 DOI: 10.1088/1361-6528/ac75fb] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 06/05/2022] [Indexed: 06/15/2023]
Abstract
The detection of cholesterol is very crucial in clinical diagnosis for rapid and accurate monitoring of multiple disease-biomarkers. There is a great need for construction of a highly reliable and stable electrocatalyst for the efficient detection of cholesterol. In this work, mesoporous NiCo2S4nanoflakes of enhanced electrochemical properties are prepared through a facile hydrothermal approach. The developed nanoflakes modified nickel foam electrode exhibits outstanding electrocatalytic properties for the detection of cholesterol with high selectivity. The electrode displays excellent sensitivity of 8623.6μA mM-1cm-2, in the wide linear range from 0.01 to 0.25 mM with a low detection limit of 0.01μM. In addition, NiCo2S4structure reveals good thermal stability and reproducibility over a period of 8 weeks. Moreover, the nanoflakes show good response for detection of cholesterol in real samples. Our results demonstrate the potential use of NiCo2S4as a catalyst for the development of cost-effective electrochemical sensors for medical and industrial applications.
Collapse
Affiliation(s)
- Syeda Sughra Rabbani
- Nanomaterials Research Group, Physics Division, PINSTECH, Islamabad 44000, Pakistan
- Department of Physics, Riphah International University, Islamabad 46000, Pakistan
| | - Amjad Nisar
- Nanomaterials Research Group, Physics Division, PINSTECH, Islamabad 44000, Pakistan
| | - Amina Zafar
- Nanomaterials Research Group, Physics Division, PINSTECH, Islamabad 44000, Pakistan
- Central Analytical Facility Division, PINSTECH, Islamabad 44000, Pakistan
| | - Yanguo Liu
- School of Resources and Materials, Northeastern University at Qinhuangdao, Qinhuangdao 066004, People's Republic of China
| | - Hongyu Sun
- School of Resources and Materials, Northeastern University at Qinhuangdao, Qinhuangdao 066004, People's Republic of China
| | - Shafqat Karim
- Nanomaterials Research Group, Physics Division, PINSTECH, Islamabad 44000, Pakistan
| | - Shafqat Hussain
- Nanomaterials Research Group, Physics Division, PINSTECH, Islamabad 44000, Pakistan
| | - Atta Ullah Shah
- National Institute of Lasers and Optronics College, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad 45650, Pakistan
| | | | - Nasir Mehboob
- Department of Physics, Riphah International University, Islamabad 46000, Pakistan
| | - Yanlong Yu
- College of Chemistry and Chemical Engineering, Northeast Petroleum University, Daqing, 163318, People's Republic of China
| | - Mashkoor Ahmad
- Nanomaterials Research Group, Physics Division, PINSTECH, Islamabad 44000, Pakistan
| |
Collapse
|
104
|
Laser-assisted surface activation for fabrication of flexible non-enzymatic Cu-based sensors. Mikrochim Acta 2022; 189:259. [PMID: 35704127 DOI: 10.1007/s00604-022-05347-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 05/15/2022] [Indexed: 10/18/2022]
Abstract
A rapid and effective technique has been develped for the fabrication of sensor-active copper-based materials on the surface of such flexible polymers as terephthalate, polyethylene naphthalate, and polyimide using the method of laser surface modification. For this purpose, we optimized the polymer surface activation parameters using laser sources with a picosecond pulse duration for subsequent selective metallization within the activated region. Furthermore, the fabricated copper structures were modified with gold nanostructures and by electrochemical passivation to produce copper-gold and oxide-containing copper species, respectively. As a result, in comparison with pure copper electrodes, these composite materials exhibit much better electrocatalytic performance concerning the non-enzymatic identification of biologically important disease markers such as glucose, hydrogen peroxide, and dopamine.
Collapse
|
105
|
Lv HW, Li QF, Peng HL. Protein templated Au-CuO bimetallic nanoclusters toward neutral glucose sensing. CHINESE J CHEM PHYS 2022. [DOI: 10.1063/1674-0068/cjcp2005076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
In this study, the application of bovine serum albumin (BSA) as a carrier to glucose-sensitive materials for the detection of glucose was proposed. Au-CuO bimetallic nanoclusters (Au-CuO/BSA) were prepared using BSA as a template, the new sensing material (Au-CuO/BSA/MWCNTs) was synthesized by mixing with multi-walled carbon nanotubes (MWCNT) and applied to non-enzymatic electrochemical sensors to detect glucose stably and effectively under neutral condition. The scanning electron microscopy was used to investigate the morphology of the synthesized nanocomposite. The electrochemical properties of the sensor were studied by cyclic voltammetry. Glucose detection experiments show that Au-CuO/BSA/MWCNTs/Au electrode has good glucose detection ability, stability, accuracy, repeatability, and high selectivity in neutral environment. Unlike existing glucose-sensitive materials, due to the use of BSA, the composite material is firmly fixed to the electrode surface without a Nafion solution, which reduces the current blocking effect on the modified electrode. The composite materials can be effectively preserved for extremely long periods, higher than 80% activity is maintained at room temperature in a closed environment for 3 to 4 months, due to the special effects of BSA. In addition, the feasibility of using BSA in glucose-sensitive materials is confirmed.
Collapse
Affiliation(s)
- Hong-wei Lv
- College of Electronic Engineering, Guangxi Normal University, Guilin 541004, China
| | - Quan-fu Li
- College of Electronic Engineering, Guangxi Normal University, Guilin 541004, China
| | - Hui-ling Peng
- College of Electronic Engineering, Guangxi Normal University, Guilin 541004, China
| |
Collapse
|
106
|
Rani P, Ahmed B, Singh J, Kaur J, Rawat M, Kaur N, Matharu AS, AlKahtani M, Alhomaidi EA, Lee J. Silver nanostructures prepared via novel green approach as an effective platform for biological and environmental applications. Saudi J Biol Sci 2022; 29:103296. [PMID: 35574283 PMCID: PMC9092993 DOI: 10.1016/j.sjbs.2022.103296] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 03/14/2022] [Accepted: 04/17/2022] [Indexed: 02/07/2023] Open
Abstract
Silver nanoparticles play a significant role in biomedical sciences due to their unique properties allowing for their use as an effective sensing and remediation platform Herein, the green synthesis of silver nanostructures (Ag NSs), prepared via aqueous extract of waste Brassica oleracea leaves in the presence of silver nitrate solution (10-4 M), is reported. The Ag NSs are fully characterized and their efficacy with respect to 4-nitrophenol reduction, glucose sensing, and microbes is determined. Visually, the color of silver nitrate containing solution altered from colorless to yellowish, then reddish grey, confirming the formation of Ag NSs. HRTEM and SEAD studies revealed the Ag NSs to have different morphologies (triangular, rod-shaped, hexagonal, etc., within a size range of 20-40 nm) with face-centered cubic (fcc) crystal structure. The Ag NSs possess high efficacy for nitrophenol reduction (<11 min and degradation efficiency of 98.2%), glucose sensing (LOD: 5.83 µM), and antimicrobial activity (E. coli and B. subtilis with clearance zones of 18.3 and 14 mm, respectively). Thus, the current study alludes towards the development of a cost-effective, sustainable, and efficient three-in-one platform for biomedical and environmental applications.
Collapse
Affiliation(s)
- Pooja Rani
- Department of Nanotechnology, Sri Guru Granth Sahib World University, Fatehgarh Sahib 140406, Punjab, India
| | - Bilal Ahmed
- School of Chemical Engineering, Yeungnam University, Republic of Korea
| | - Jagpreet Singh
- Department of Chemical Engineering, Chandigarh University, Gharuan, Mohali 140413, India
- University Centre for Research and Development, Chandigarh University, Gharuan, Mohali 140413, India
| | - Jasmeen Kaur
- Department of Biotechnology, Sri Guru Granth Sahib World University, Fatehgarh Sahib 140406, Punjab, India
| | - Mohit Rawat
- Department of Nanotechnology, Sri Guru Granth Sahib World University, Fatehgarh Sahib 140406, Punjab, India
| | - Navjot Kaur
- Rayat Institute of Pharmacy, Railmajra, SBS Nagar, Punjab 144533, India
| | - Avtar Singh Matharu
- Green Chemistry Centre of Excellence, Department of Chemistry, University of York, York YO10 5DD, UK
| | - Muneera AlKahtani
- Department of Biology, College of Sciences, Princess Nourah bint Abdulrahman University, P.O.Box 84428, Riyadh 11671, Saudi Arabia
| | - Eman A.H. Alhomaidi
- Department of Biology, College of Sciences, Princess Nourah bint Abdulrahman University, P.O.Box 84428, Riyadh 11671, Saudi Arabia
| | - Jintae Lee
- School of Chemical Engineering, Yeungnam University, Republic of Korea
| |
Collapse
|
107
|
Farid A, Khan AS, Javid M, Usman M, Khan IA, Ahmad AU, Fan Z, Khan AA, Pan L. Construction of a binder-free non-enzymatic glucose sensor based on Cu@Ni core-shell nanoparticles anchored on 3D chiral carbon nanocoils-nickel foam hierarchical scaffold. J Colloid Interface Sci 2022; 624:320-337. [PMID: 35660901 DOI: 10.1016/j.jcis.2022.05.137] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 05/19/2022] [Accepted: 05/22/2022] [Indexed: 01/09/2023]
Abstract
Bimetallic nanostructures composited with carbonaceous materials are the potential contenders for quantitative glucose measurement owing to their unique nanostructures, high biomimetic activity, synergistic effects, good conductivity and chemical stability. In the present work, chemical vapors deposition technique has been employed to grow 3D carbon nanocoils (CNCs) with a chiral morphology on hierarchical macroporous nickel foam (NF) to get a CNCs/NF scaffold. Following, bimetallic Cu@Ni core-shell nanoparticles (CSNPs) are effectively coupled with this scaffold through a facile solvothermal route in order to fabricate a binder-free novel Cu@Ni CSNPs/CNCs/NF hybrid nanostructure. The constructed free-standing 3D hierarchical composite electrode guarantees highly efficient glucose redox activity due to core-shell synergistic effects, enhanced electrochemical active surface area, excellent electrochemical stability, improved conductivity with better ion diffusivity and accelerated reaction kinetics. Being a non-enzymatic glucose sensor, this electrode achieves highly swift response time of 0.1 s, ultra-high sensitivity of 6905 μA mM-1 cm-2, low limit of detection of 0.03 μM along with potential selectivity and good storage stability. Moreover, the proposed sensor is also tested successfully for the determination of glucose concentration in human serum samples under good recovery ranging from 96.6 to 102.1 %. The 3D Cu@Ni CSNPs/CNCs/NF composite electrode with unprecedented catalytic performance can be utilized as an ideal biomimetic catalyst in the field of non-enzymatic glucose sensing.
Collapse
Affiliation(s)
- Amjad Farid
- School of Physics, Dalian University of Technology, Dalian 116024, PR China; Department of Physics, Government College University Faisalabad, Faisalabad 38000, Pakistan
| | - Abdul Sammed Khan
- School of Physics, Dalian University of Technology, Dalian 116024, PR China
| | - Muhammad Javid
- School of Physics, Dalian University of Technology, Dalian 116024, PR China
| | - Muhammad Usman
- Department of Physics, Khawaja Fareed University of Engineering and Information Technology, Rahim Yar Khan 64200, Pakistan
| | - Ijaz Ahmad Khan
- Department of Physics, Government College University Faisalabad, Faisalabad 38000, Pakistan
| | - Aqrab Ul Ahmad
- Department of Physics, Riphah International University Faisalabad Campus, Faisalabad 38000, Pakistan
| | - Zeng Fan
- School of Physics, Dalian University of Technology, Dalian 116024, PR China
| | - Aqib Ali Khan
- Department of Physics, Islamia College Peshawar, Peshawar 25120, KP, Pakistan
| | - Lujun Pan
- School of Physics, Dalian University of Technology, Dalian 116024, PR China.
| |
Collapse
|
108
|
Arif D, Hussain Z, Abbasi AD, Sohail M. Ag Functionalized In2O3 Derived From MIL-68(In) as an Efficient Electrochemical Glucose Sensor. Front Chem 2022; 10:906031. [PMID: 35615318 PMCID: PMC9124854 DOI: 10.3389/fchem.2022.906031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 04/19/2022] [Indexed: 11/13/2022] Open
Abstract
In this study, Ag@In2O3 modified nickel foam (NF) was reported for its role as a non-enzymatic glucose sensor. Ag@In2O3 was prepared by a simple two-step method; preparation of a metal-organic framework (MOF) MIL-68(In) by solvothermal method, entrapment of Ag + by adding AgNO3 then drying it for 2 h to complete the entrapment process and subsequent calcination at 650°C for 3 h. The Ag@In2O3 modified NF was employed as a non-enzymatic glucose sensor to determine glucose concentrations in an alkaline medium. Two linear ranges were obtained from Ag@In2O3 modified electrode, i.e., 10 μM to 0.8 mM and 0.8–2.16 mM with a sensitivity of 3.31 mA mM−1 cm−2 and 1.51 mA mM−1 cm−2 respectively, with a detection limit of 0.49 µM. Ag@In2O3 modified NF exhibited high selectivity for glucose, among other interfering agents.
Collapse
Affiliation(s)
- Dooa Arif
- Department of Materials Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences & Technology (NUST), Islamabad, Pakistan
| | - Zakir Hussain
- Department of Materials Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences & Technology (NUST), Islamabad, Pakistan
- *Correspondence: Zakir Hussain,
| | - Amna Didar Abbasi
- Department of Materials Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences & Technology (NUST), Islamabad, Pakistan
| | - Manzar Sohail
- Department of Chemistry, School of Natural Sciences (SNS), National University of Sciences & Technology (NUST), Islamabad, Pakistan
| |
Collapse
|
109
|
Wang X, Li Y, Zhao M, Wang H, Wan Q, Shi C, Ma C. An ultrafast ratiometric electrochemical biosensor based on potential-assisted hybridization for nucleic acids detection. Anal Chim Acta 2022; 1211:339915. [DOI: 10.1016/j.aca.2022.339915] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 04/29/2022] [Accepted: 05/04/2022] [Indexed: 01/24/2023]
|
110
|
Zn2+ induced self-assembled fabrication of marigold-like ZnO microflower@Ni(OH)2 three-dimensional nanosheets for nonenzymatic glucose sensing. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140040] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
111
|
Chang AS, Tahira A, Solangi ZA, Solangi AG, Ibupoto MH, Chang F, Medany SS, Nafady A, Kasry A, Willander M, Ibupoto ZH. Pd-Co3O4-based nanostructures for the development of enzyme-free glucose sensor. BULLETIN OF MATERIALS SCIENCE 2022; 45:62. [DOI: 10.1007/s12034-021-02642-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Accepted: 11/23/2021] [Indexed: 07/11/2023]
|
112
|
Zheng Y, Li Y, Fan L, Yao H, Zhang Z. An amphiprotic paper-based electrode for glucose detection based on layered carbon nanotubes with silver and polystyrene particles. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1268-1278. [PMID: 35274112 DOI: 10.1039/d1ay01950c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In this work, a flexible amphiprotic amino-bonded carbon nanotube-Ag nanoparticle/polystyrene (CNT-NH2-Ag/PS) paper electrode was fabricated to measure glucose in human body fluids by a combination of vacuum filtration and high temperature baking. The front side of the fabricated paper electrode was hydrophobic and conductive, whereas its back side was hydrophilic and nonconductive. In the fabrication process, the coating sequence of CNT-NH2, Ag and PS was critical to determine the performance of the resulting CNT-NH2-Ag/PS electrode besides other parameters (e.g., amount of soluble starch, PS and Ag nanoparticles, type and amount of CNT-NH2, and electrode sensing area). Based on a series of experimental observations, the possible mechanism of glucose detection on the paper electrode was proposed, in which glucose was more favorable to migrate to the hydrophilic back side of the paper and interact with the active species (e.g., O2-) on the electrode surface. The electrochemical results showed that the CNT-NH2-Ag/PS paper electrode maintained stable electrochemical properties even after five cycles of use and 60 days of storage in air. The amphiprotic paper electrode demonstrated excellent sensing performance for glucose with a linear range of 1 μM to 1000 μM, a low detection limit of 0.2 μM, and a sensitivity of 31 333.0 μA mM-1 cm-2. The fabricated paper electrode was also successfully applied to detect different levels of glucose in complex human body fluids such as saliva, urine, and serum. These features make this type of paper electrode promising for glucose measurement.
Collapse
Affiliation(s)
- Yajun Zheng
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Yu Li
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Libin Fan
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Hedan Yao
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Zhiping Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| |
Collapse
|
113
|
Ayaz S, Karakaya S, Emir G, Uşaklıgil N, Giray Dilgin D, Dilgin Y. Flow-Injection Amperometric Determination of Glucose Using Nickel Oxide-Cobalt (II,III) Oxide and Nickel Oxide-Copper Nanoparticle Modified Pencil Graphite Electrodes. ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2043890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Selen Ayaz
- Department of Chemistry, Faculty of Arts and Sciences, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Serkan Karakaya
- Department of Chemistry, Faculty of Arts and Sciences, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Gamze Emir
- Department of Chemistry, Faculty of Arts and Sciences, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Nihan Uşaklıgil
- Department of Biochemistry, Medical Park Hospital Çanakkale, Çanakkale, Turkey
| | - Didem Giray Dilgin
- Department of Mathematics and Science Education, Faculty of Education, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Yusuf Dilgin
- Department of Chemistry, Faculty of Arts and Sciences, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| |
Collapse
|
114
|
Arikan K, Burhan H, Bayat R, Sen F. Glucose nano biosensor with non-enzymatic excellent sensitivity prepared with nickel-cobalt nanocomposites on f-MWCNT. CHEMOSPHERE 2022; 291:132720. [PMID: 34743867 DOI: 10.1016/j.chemosphere.2021.132720] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 10/12/2021] [Accepted: 10/25/2021] [Indexed: 06/13/2023]
Abstract
NiCo (Nickel-cobalt) nanoparticles were obtained by the chemical reduction method on functionalized multi-walled carbon nanotubes. After this process, chronoamperometry, cyclic voltammetry, and amperometric methods were used to investigate the electrochemical and electrocatalytic behavior of NiCo@f-MWCNT against glucose oxidation. In addition, the NiCo@f-MWCNT nanocomposites were analyzed by characterization techniques such as X-Ray Diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Transmission Electron Microscopy (TEM), and Atomic Force Microscopy (AFM) in terms of the morphological and atomic structure of prepared nanomaterials. The sensitivity and limit of detection the non-enzymatic glucose sensor (NiCo@f-MWCNT) were calculated as 10,015 μA/mM-1 cm-2 0.26 μM, respectively. As a result of these studies and experiments, the NiCo@f-MWCNT nanocomposite is a really good sensor and their stability showed that the current nanomaterials expressed to be new material for the electrochemical detection of glucose.
Collapse
Affiliation(s)
- Kubilay Arikan
- Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupınar University, Evliya Celebi Campus, 43100, Kutahya, Turkey
| | - Hakan Burhan
- Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupınar University, Evliya Celebi Campus, 43100, Kutahya, Turkey
| | - Ramazan Bayat
- Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupınar University, Evliya Celebi Campus, 43100, Kutahya, Turkey
| | - Fatih Sen
- Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupınar University, Evliya Celebi Campus, 43100, Kutahya, Turkey.
| |
Collapse
|
115
|
Zhan T, Feng XZ, An QQ, Li S, Xue M, Chen Z, Han GC, Kraatz HB. Enzyme-free glucose sensors with efficient synergistic electro-catalysis based on a ferrocene derivative and two metal nanoparticles. RSC Adv 2022; 12:5072-5079. [PMID: 35425584 PMCID: PMC8981370 DOI: 10.1039/d1ra09213h] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 01/25/2022] [Indexed: 01/07/2023] Open
Abstract
Gold electrodes (GE) were modified by the deposition of copper nanoparticles (CuNPs) and cobalt nanoparticles (CoNPs), followed by drop-casting of the ferrocene derivative FcCO-Glu-Cys-Gly-OH (Fc-ECG), resulting in two enzyme-free electrochemical sensors Fc-ECG/CuNPs/GE and Fc-ECG/CuNPs/GE. The ferrocene-peptide conjugate acts as an effective redox mediator for glucose oxidation, while metal nanoparticles acted as non-biological sites for glucose oxidation. Field emission scanning electron microscopy (FESEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were carried out for characterization, while differential pulse voltammetry (DPV) was used for glucose quantification. Under optimized conditions, DPV shows a linear relationship between glucose concentration and the peak current. Both sensors showed a surprisingly high sensitivity of 217.27 and 378.70 μA mM-1 cm-2, respectively. A comparison to other glucose sensors shows a sensitivity that is 25 times higher. The sensors exhibit good reproducibility, stability, and repeatability. In injection experiments, recovery rates were 87.39-107.65% and 100.00-106.88%, respectively.
Collapse
Affiliation(s)
- Tao Zhan
- College of Electronic Engineering and Automation, Guilin University of Electronic Technology Guilin 541004 P. R. China
- School of Life and Environmental Sciences, Guilin University of Electronic Technology Guilin 541004 P. R. China
| | - Xiao-Zhen Feng
- School of Life and Environmental Sciences, Guilin University of Electronic Technology Guilin 541004 P. R. China
| | - Qi-Qi An
- School of Life and Environmental Sciences, Guilin University of Electronic Technology Guilin 541004 P. R. China
| | - Shiyong Li
- College of Electronic Engineering and Automation, Guilin University of Electronic Technology Guilin 541004 P. R. China
| | - Mingyue Xue
- School of Life and Environmental Sciences, Guilin University of Electronic Technology Guilin 541004 P. R. China
| | - Zhencheng Chen
- College of Electronic Engineering and Automation, Guilin University of Electronic Technology Guilin 541004 P. R. China
- School of Life and Environmental Sciences, Guilin University of Electronic Technology Guilin 541004 P. R. China
| | - Guo-Cheng Han
- School of Life and Environmental Sciences, Guilin University of Electronic Technology Guilin 541004 P. R. China
| | - Heinz-Bernhard Kraatz
- Department of Physical and Environmental Sciences, University of Toronto Scarborough Toronto Ontario M1C 1A4 Canada
| |
Collapse
|
116
|
Song Y, He T, Zhang Y, Yin C, Chen Y, Liu Q, Zhang Y, Chen S. Cobalt single atom sites in carbon aerogels for ultrasensitive enzyme-free electrochemical detection of glucose. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116024] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
117
|
Mao X, Zhang C. A microfluidic cloth-based photoelectrochemical analytical device for the detection of glucose in saliva. Talanta 2022; 238:123052. [PMID: 34808571 DOI: 10.1016/j.talanta.2021.123052] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 10/18/2021] [Accepted: 11/07/2021] [Indexed: 02/08/2023]
Abstract
Photoelectrochemical (PEC) detection is a widely used detection method that uses light to stimulate and photocurrent signals to detect the target. Due to the disengagement of the excitation unit and the detection unit, the PEC background signal is reduced, and the detection sensitivity is improved. In this work, we report the first demonstration of PEC detection for microfluidic cloth-based analytical devices (μCADs). Using PEC μCADs integrated with cadmium sulfide quantum dots (CdS QDs) and multiwalled carbon nanotubes (MWCNTs), the nonenzymatic, sensitive and rapid measurement of glucose in saliva has been achieved. For the cloth-based device, the PEC reaction zone and cloth-based electrodes can be fabricated by inexpensive wax-based and carbon ink-based screen-printing, respectively. By the layer-by-layer method, the as-prepared poly (dimethyl diadly ammonium chloride-functionalized) MWCNTs (PDDA-MWCNTs) and CdS QDs are successively adsorbed onto the working electrode surface of the cloth-based device. In the presence of an excitation source and glucose, the CdS QDs generate a strong oxidizing electron hole that can then continuously oxidize glucose to produce an electrical signal for glucose detection. Under optimized conditions, a linear dependence is obtained between the PEC signal and glucose concentrations in the range of 0.05-1000 μM with a detection limit of 15.99 nM. In the detection range, the cloth-based device also shows acceptable selectivity, reproducibility, and long-term stability. Moreover, the method has been implemented for the detection of glucose in real saliva samples, suggesting good potential for biochemical applications.
Collapse
Affiliation(s)
- Xinyuan Mao
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Chunsun Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
| |
Collapse
|
118
|
Highly sensitive and selective non-enzymatic measurement of glucose using arraying of two separate sweat sensors at physiological pH. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
119
|
Lin W, He M, Gao L, Zhong H, Ye S, Li H. An enzyme-free monosaccharide fuel cell using bio-mimetically hemin-intercalated polydopamine as anode and cathode catalysts. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.139830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
120
|
How to fit a response current-concentration curve? Part (Ⅱ): Synergy of heterogeneous PANI@Ni(OH)2/NF towards high performance glucose sensing and a general semi-empirical model. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
121
|
Jeerapan I, Moonla C, Thavarungkul P, Kanatharana P. Lab on a body for biomedical electrochemical sensing applications: The next generation of microfluidic devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 187:249-279. [PMID: 35094777 DOI: 10.1016/bs.pmbts.2021.07.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
This chapter highlights applications of microfluidic devices toward on-body biosensors. The emerging application of microfluidics to on-body bioanalysis is a new strategy to establish systems for the continuous, real-time, and on-site determination of informative markers present in biofluids, such as sweat, interstitial fluid, blood, saliva, and tear. Electrochemical sensors are attractive to integrate with such microfluidics due to the possibility to be miniaturized. Moreover, on-body microfluidics coupled with bioelectronics enable smart integration with modern information and communication technology. This chapter discusses requirements and several challenges when developing on-body microfluidics such as difficulties in manipulating small sample volumes while maintaining mechanical flexibility, power-consumption efficiency, and simplicity of total automated systems. We describe key components, e.g., microchannels, microvalves, and electrochemical detectors, used in microfluidics. We also introduce representatives of advanced lab-on-a-body microfluidics combined with electrochemical sensors for biomedical applications. The chapter ends with a discussion of the potential trends of research in this field and opportunities. On-body microfluidics as modern total analysis devices will continue to bring several fascinating opportunities to the field of biomedical and translational research applications.
Collapse
Affiliation(s)
- Itthipon Jeerapan
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand.
| | - Chochanon Moonla
- School of Chemistry, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, Thailand
| | - Panote Thavarungkul
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Proespichaya Kanatharana
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| |
Collapse
|
122
|
Hydrogen-assisted synthesis of Ni-ZIF-derived nickel nanoparticle chains coated with nitrogen-doped graphitic carbon layers as efficient electrocatalysts for non-enzymatic glucose detection. Mikrochim Acta 2022; 189:80. [DOI: 10.1007/s00604-022-05172-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 01/03/2022] [Indexed: 10/19/2022]
|
123
|
Chalil Oglou R, Ulusoy Ghobadi TG, Ozbay E, Karadas F. Selective Glucose Sensing under Physiological pH with Flexible and Binder‐Free Prussian Blue Coated Carbon Cloth Electrodes. ChemElectroChem 2022. [DOI: 10.1002/celc.202101355] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Ramadan Chalil Oglou
- Institute of Material Science and Nanotechnology, UNAM – National Nanotechnology Research Center Bilkent University Ankara 06800 Turkey
| | | | - Ekmel Ozbay
- NANOTAM – Nanotechnology Research Center, Department of Electrical and Electronics Engineering Department of Physics Bilkent University Ankara 06800 Turkey
| | - Ferdi Karadas
- Department of Chemistry Bilkent University Ankara 06800 Turkey
- Institute of Material Science and Nanotechnology, UNAM – National Nanotechnology Research Center Bilkent University Ankara 06800 Turkey
| |
Collapse
|
124
|
Falahi S, Jaafar A, Petrenko I, Zarejousheghani M, Ehrlich H, Rahimi P, Joseph Y. High-Performance Three-Dimensional Spongin-Atacamite Biocomposite for Electrochemical Nonenzymatic Glucose Sensing. ACS APPLIED BIO MATERIALS 2022; 5:873-880. [PMID: 35050590 DOI: 10.1021/acsabm.1c01248] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
The design of sensitive and cost-effective biocomposite materials with high catalytic activity for the effective electrooxidation of glucose plays a key role in developing enzyme-free glucose sensors. The porous three-dimensional (3D) spongin scaffold of marine sponge origin provides an excellent template for the growth of atacamite crystals and improves the activity of atacamite as a catalyst. By using the design of experiment method, the influence of different parameters on the electrode efficiency was optimized. The optimized sensor based on spongin-atacamite showed distinguished performance toward glucose with two linear ranges of 0.4-200 μM and 0.2-10 mM and high sensitivities of 3908.4 and 600.5 μA mM-1 cm-2, respectively. Importantly, the designed sensor exhibited strong selectivity and favorable stability, reproducibility, and repeatability. The performance in the real application was estimated by glucose detection in spiked human blood serum samples, which verified its great potential as a reliable platform for enzyme-free glucose sensing.
Collapse
Affiliation(s)
- Sedigheh Falahi
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Alaa Jaafar
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Iaroslav Petrenko
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Mashaalah Zarejousheghani
- Freiberg Water Research Center, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Hermann Ehrlich
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Parvaneh Rahimi
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany.,Freiberg Water Research Center, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Yvonne Joseph
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany.,Freiberg Water Research Center, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| |
Collapse
|
125
|
Zafar H, Channa A, Jeoti V, Stojanović GM. Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring. SENSORS (BASEL, SWITZERLAND) 2022; 22:638. [PMID: 35062598 PMCID: PMC8781973 DOI: 10.3390/s22020638] [Citation(s) in RCA: 68] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/16/2021] [Accepted: 12/31/2021] [Indexed: 02/07/2023]
Abstract
The incidence of diabetes is increasing at an alarming rate, and regular glucose monitoring is critical in order to manage diabetes. Currently, glucose in the body is measured by an invasive method of blood sugar testing. Blood glucose (BG) monitoring devices measure the amount of sugar in a small sample of blood, usually drawn from pricking the fingertip, and placed on a disposable test strip. Therefore, there is a need for non-invasive continuous glucose monitoring, which is possible using a sweat sensor-based approach. As sweat sensors have garnered much interest in recent years, this study attempts to summarize recent developments in non-invasive continuous glucose monitoring using sweat sensors based on different approaches with an emphasis on the devices that can potentially be integrated into a wearable platform. Numerous research entities have been developing wearable sensors for continuous blood glucose monitoring, however, there are no commercially viable, non-invasive glucose monitors on the market at the moment. This review article provides the state-of-the-art in sweat glucose monitoring, particularly keeping in sight the prospect of its commercialization. The challenges relating to sweat collection, sweat sample degradation, person to person sweat amount variation, various detection methods, and their glucose detection sensitivity, and also the commercial viability are thoroughly covered.
Collapse
Affiliation(s)
- Hima Zafar
- Faculty of Technical Sciences, University of Novi Sad, T. Dositeja Obradovića 6, 21000 Novi Sad, Serbia; (V.J.); (G.M.S.)
| | - Asma Channa
- Computer Science Department, University Politehnica of Bucharest, 060042 Bucharest, Romania;
- DIIES Department, Mediterranea University of Reggio Calabria, 89100 Reggio Calabria, Italy
| | - Varun Jeoti
- Faculty of Technical Sciences, University of Novi Sad, T. Dositeja Obradovića 6, 21000 Novi Sad, Serbia; (V.J.); (G.M.S.)
| | - Goran M. Stojanović
- Faculty of Technical Sciences, University of Novi Sad, T. Dositeja Obradovića 6, 21000 Novi Sad, Serbia; (V.J.); (G.M.S.)
| |
Collapse
|
126
|
Behnam Nourmohammadi Khiarak, Imanparast S, Yengejeh MM, Zahraei AA, Yaghobi R, Golmohammad M. Efficient Water Oxidation Catalyzed by a Graphene Oxide/Copper Electrode, Supported on Carbon Cloth. RUSS J ELECTROCHEM+ 2022. [DOI: 10.1134/s1023193521100062] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
127
|
Khor SM, Choi J, Won P, Ko SH. Challenges and Strategies in Developing an Enzymatic Wearable Sweat Glucose Biosensor as a Practical Point-Of-Care Monitoring Tool for Type II Diabetes. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:221. [PMID: 35055239 PMCID: PMC8781831 DOI: 10.3390/nano12020221] [Citation(s) in RCA: 40] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 01/07/2022] [Accepted: 01/08/2022] [Indexed: 01/27/2023]
Abstract
Recently, several studies have been conducted on wearable biosensors. Despite being skin-adhesive and mountable diagnostic devices, flexible biosensor patches cannot truly be considered wearable biosensors if they need to be connected to external instruments/processors to provide meaningful data/readings. A realistic and usable wearable biosensor should be self-contained, with a fully integrated device framework carefully designed and configured to provide reliable and intelligent diagnostics. There are several major challenges to achieving continuous sweat monitoring in real time for the systematic and effective management of type II diabetes (e.g., prevention, screening, monitoring, and treatment) through wearable sweat glucose biosensors. Consequently, further in-depth research regarding the exact interrelationship between active or passive sweat glucose and blood glucose is required to assess the applicability of wearable glucose biosensors in functional health monitoring. This review provides some useful insights that can enable effective critical studies of these unresolved issues. In this review, we first classify wearable glucose biosensors based on their signal transduction, their respective challenges, and the advanced strategies required to overcome them. Subsequently, the challenges and limitations of enzymatic and non-enzymatic wearable glucose biosensors are discussed and compared. Ten basic criteria to be considered and fulfilled in the development of a suitable, workable, and wearable sweat-based glucose biosensor are listed, based on scientific reports from the last five years. We conclude with our outlook for the controllable, well-defined, and non-invasive monitoring of epidermal glucose for maximum diagnostic potential in the effective management of type II diabetes.
Collapse
Affiliation(s)
- Sook Mei Khor
- Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea; (S.M.K.); (J.C.)
- Department of Chemistry, Faculty of Science, Universiti Malaya, Kuala Lumpur 50603, Malaysia
| | - Joonhwa Choi
- Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea; (S.M.K.); (J.C.)
| | - Phillip Won
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213, USA;
| | - Seung Hwan Ko
- Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea; (S.M.K.); (J.C.)
- Institute of Advanced Machines and Design/Institute of Engineering Research, Seoul National University, Seoul 08826, Korea
| |
Collapse
|
128
|
Varghese EV, Saidu FK, Schwandt C, Thomas G, Joseph A. Non‐Enzymatic Electrochemical Biosensing of Glucose Using Nanocomposites of Polyaniline Nanofibers and Silver. ChemistrySelect 2022. [DOI: 10.1002/slct.202103518] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
| | | | - Carsten Schwandt
- Department of Materials Science and Metallurgy University of Cambridge Cambridge CB3 0FS United Kingdom
| | | | - Alex Joseph
- Department of Chemistry Newman College Thodupuzha Kerala 685585 India
| |
Collapse
|
129
|
Balkourani G, Damartzis T, Brouzgou A, Tsiakaras P. Cost Effective Synthesis of Graphene Nanomaterials for Non-Enzymatic Electrochemical Sensors for Glucose: A Comprehensive Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:355. [PMID: 35009895 PMCID: PMC8749877 DOI: 10.3390/s22010355] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 12/20/2021] [Accepted: 12/25/2021] [Indexed: 02/06/2023]
Abstract
The high conductivity of graphene material (or its derivatives) and its very large surface area enhance the direct electron transfer, improving non-enzymatic electrochemical sensors sensitivity and its other characteristics. The offered large pores facilitate analyte transport enabling glucose detection even at very low concentration values. In the current review paper we classified the enzymeless graphene-based glucose electrocatalysts' synthesis methods that have been followed into the last few years into four main categories: (i) direct growth of graphene (or oxides) on metallic substrates, (ii) in-situ growth of metallic nanoparticles into graphene (or oxides) matrix, (iii) laser-induced graphene electrodes and (iv) polymer functionalized graphene (or oxides) electrodes. The increment of the specific surface area and the high degree reduction of the electrode internal resistance were recognized as their common targets. Analyzing glucose electrooxidation mechanism over Cu- Co- and Ni-(oxide)/graphene (or derivative) electrocatalysts, we deduced that glucose electrochemical sensing properties, such as sensitivity, detection limit and linear detection limit, totally depend on the route of the mass and charge transport between metal(II)/metal(III); and so both (specific area and internal resistance) should have the optimum values.
Collapse
Affiliation(s)
- Georgia Balkourani
- Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, University of Thessaly, Pedion Areos, 38334 Volos, Greece;
| | - Theodoros Damartzis
- Industrial Processes and Energy Systems Engineering, Institute of Mechanical Engineering, Sion, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland;
| | - Angeliki Brouzgou
- Department of Energy Systems, School of Technology, University of Thessaly, Geopolis, Regional Road Trikala-Larisa, 41500 Larisa, Greece
| | - Panagiotis Tsiakaras
- Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, University of Thessaly, Pedion Areos, 38334 Volos, Greece;
- Laboratory of Materials and Devices for Electrochemical Power Engineering, Institute of Chemical Engineering, Ural Federal University, 19 Mira Str., 620002 Yekaterinburg, Russia
- Laboratory of Electrochemical Devices Based on Solid Oxide Proton Electrolytes, Institute of High Temperature Electrochemistry (RAS), 620990 Yekaterinburg, Russia
| |
Collapse
|
130
|
Pullano SA, Greco M, Bianco MG, Foti D, Brunetti A, Fiorillo AS. Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices. Theranostics 2022; 12:493-511. [PMID: 34976197 PMCID: PMC8692922 DOI: 10.7150/thno.64035] [Citation(s) in RCA: 40] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 10/31/2021] [Indexed: 12/13/2022] Open
Abstract
The demand of glucose monitoring devices and even of updated guidelines for the management of diabetic patients is dramatically increasing due to the progressive rise in the prevalence of diabetes mellitus and the need to prevent its complications. Even though the introduction of the first glucose sensor occurred decades ago, important advances both from the technological and clinical point of view have contributed to a substantial improvement in quality healthcare. This review aims to bring together purely technological and clinical aspects of interest in the field of glucose devices by proposing a roadmap in glucose monitoring and management of patients with diabetes. Also, it prospects other biological fluids to be examined as further options in diabetes care, and suggests, throughout the technology innovation process, future directions to improve the follow-up, treatment, and clinical outcomes of patients.
Collapse
Affiliation(s)
| | - Marta Greco
- Department of Health Sciences, Magna Græcia University of Catanzaro, 88100, Catanzaro, Italy
| | - Maria Giovanna Bianco
- Department of Health Sciences, Magna Græcia University of Catanzaro, 88100, Catanzaro, Italy
| | - Daniela Foti
- Department of Experimental and Clinical Medicine, Magna Græcia University of Catanzaro, 88100, Catanzaro, Italy
| | - Antonio Brunetti
- Department of Health Sciences, Magna Græcia University of Catanzaro, 88100, Catanzaro, Italy
| | - Antonino S. Fiorillo
- Department of Health Sciences, Magna Græcia University of Catanzaro, 88100, Catanzaro, Italy
| |
Collapse
|
131
|
Wikeley SM, Przybylowski J, Lozano-Sanchez P, Caffio M, James TD, Bull SD, Fletcher PJ, Marken F. Polymer indicator displacement assay: electrochemical glucose monitoring based on boronic acid receptors and graphene foam competitively binding with poly-nordihydroguaiaretic acid. Analyst 2022; 147:661-670. [DOI: 10.1039/d1an01991k] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A poly-nordihydroguaiaretic acid film is employed as a voltammetric indicator for bound/unbound boronic acid sites to report on glucose and fructose concentration.
Collapse
Affiliation(s)
- Simon M. Wikeley
- Department of Chemistry, University of Bath, Claverton Down, Bath BA2 7AY, UK
| | - Jakub Przybylowski
- Department of Chemistry, University of Bath, Claverton Down, Bath BA2 7AY, UK
| | | | - Marco Caffio
- Integrated Graphene Ltd., Euro House, Wellgreen Place, Stirling FK8 2DJ, UK
| | - Tony D. James
- Department of Chemistry, University of Bath, Claverton Down, Bath BA2 7AY, UK
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007, China
| | - Steven D. Bull
- Department of Chemistry, University of Bath, Claverton Down, Bath BA2 7AY, UK
| | - Philip J. Fletcher
- University of Bath, Materials & Chemical Characterisation Facility, MC2, Bath BA2 7AY, UK
| | - Frank Marken
- Department of Chemistry, University of Bath, Claverton Down, Bath BA2 7AY, UK
| |
Collapse
|
132
|
Lin T, Xu Y, Zhao A, He W, Xiao F. Flexible electrochemical sensors integrated with nanomaterials for in situ determination of small molecules in biological samples: A review. Anal Chim Acta 2022; 1207:339461. [DOI: 10.1016/j.aca.2022.339461] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 01/05/2022] [Accepted: 01/06/2022] [Indexed: 12/15/2022]
|
133
|
Naikoo GA, Awan T, Salim H, Arshad F, Hassan IU, Pedram MZ, Ahmed W, Faruck HL, Aljabali AAA, Mishra V, Serrano‐Aroca Á, Goyal R, Negi P, Birkett M, Nasef MM, Charbe NB, Bakshi HA, Tambuwala MM. Fourth-generation glucose sensors composed of copper nanostructures for diabetes management: A critical review. Bioeng Transl Med 2022; 7:e10248. [PMID: 35111949 PMCID: PMC8780923 DOI: 10.1002/btm2.10248] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 08/10/2021] [Accepted: 08/13/2021] [Indexed: 01/31/2023] Open
Abstract
More than five decades have been invested in understanding glucose biosensors. Yet, this immensely versatile field has continued to gain attention from the scientific world to better understand and diagnose diabetes. However, such extensive work done to improve glucose sensing devices has still not yielded desirable results. Drawbacks like the necessity of the invasive finger-pricking step and the lack of optimization of diagnostic interventions still need to be considered to improve the testing process of diabetic patients. To upgrade the glucose-sensing devices and reduce the number of intermediary steps during glucose measurement, fourth-generation glucose sensors (FGGS) have been introduced. These sensors, made using robust electrocatalytic copper nanostructures, improve diagnostic efficiency and cost-effectiveness. This review aims to present the essential scientific progress in copper nanostructure-based FGGS in the past 10 years (2010 to present). After a short introduction, we presented the working principles of these sensors. We then highlighted the importance of copper nanostructures as advanced electrode materials to develop reliable real-time FGGS. Finally, we cover the advantages, shortcomings, and prospects for developing highly sensitive, stable, and specific FGGS.
Collapse
Affiliation(s)
- Gowhar A. Naikoo
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Tasbiha Awan
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Hiba Salim
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Fareeha Arshad
- Department of BiochemistryAligarh Muslim UniversityAligarhIndia
| | | | - Mona Zamani Pedram
- Faculty of Mechanical Engineering—Energy DivisionK.N. Toosi University of TechnologyTehranIran
| | - Waqar Ahmed
- School of Mathematics and PhysicsCollege of Science, University of LincolnLincolnUK
| | | | - Alaa A. A. Aljabali
- Departmnt of Pharmaceutics and Pharmaceutical TechnologyYarmouk UniversityIrbidJordan
| | - Vijay Mishra
- School of Pharmaceutical SciencesLovely Professional UniversityPhagwaraPunjabIndia
| | - Ángel Serrano‐Aroca
- Biomaterials and Bioengineering LabTranslational Research Centre San Alberto Magno, Catholic University of Valencia San Vicente MártirValenciaSpain
| | - Rohit Goyal
- School of Pharmaceutical SciencesShoolini University of Biotechnology and Management SciencesSolanIndia
| | - Poonam Negi
- School of Pharmaceutical SciencesShoolini University of Biotechnology and Management SciencesSolanIndia
| | - Martin Birkett
- Department of Mechanical and Construction EngineeringNorthumbria UniversityNewcastle upon TyneUK
| | - Mohamed M. Nasef
- Department of PharmacySchool of Applied Science, University of HuddersfieldUK
| | - Nitin B. Charbe
- Department of Pharmaceutical SciencesRangel College of Pharmacy, Texas A&M UniversityKingsvilleTexasUSA
| | - Hamid A. Bakshi
- School of Pharmacy and Pharmaceutical ScienceUlster UniversityColeraineUK
| | | |
Collapse
|
134
|
Li X, Qiao J, Luo D, Xu S, Liu Y, Liu H. A flexible Ni–Ag-coated nylon yarn as an electrode for non-enzymatic glucose sensing. NEW J CHEM 2022. [DOI: 10.1039/d2nj03421b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
SCNY@Ni was prepared by electrochemical deposition and exhibited excellent performance for glucose determination.
Collapse
Affiliation(s)
- Xiaozhi Li
- School of Textile Science and Engineering, Tiangong University, No. 399 BinShuiXi Road, XiQing District, Tianjin 300387, P. R. China
| | - Jutao Qiao
- School of Textile Science and Engineering, Tiangong University, No. 399 BinShuiXi Road, XiQing District, Tianjin 300387, P. R. China
| | - Dan Luo
- School of Textile Science and Engineering, Tiangong University, No. 399 BinShuiXi Road, XiQing District, Tianjin 300387, P. R. China
| | - Siyi Xu
- School of Textile Science and Engineering, Tiangong University, No. 399 BinShuiXi Road, XiQing District, Tianjin 300387, P. R. China
| | - Yuefeng Liu
- School of Textile Science and Engineering, Tiangong University, No. 399 BinShuiXi Road, XiQing District, Tianjin 300387, P. R. China
| | - Hao Liu
- School of Textile Science and Engineering, Tiangong University, No. 399 BinShuiXi Road, XiQing District, Tianjin 300387, P. R. China
| |
Collapse
|
135
|
Chalil Oglou R, Ulusoy Ghobadi TG, Ozbay E, Karadas F. Electrodeposited cobalt hexacyanoferrate electrode as a non-enzymatic glucose sensor under neutral conditions. Anal Chim Acta 2021; 1188:339188. [PMID: 34794574 DOI: 10.1016/j.aca.2021.339188] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 10/05/2021] [Accepted: 10/18/2021] [Indexed: 10/20/2022]
Abstract
A CoFe Prussian blue analogue (CoFe PB) modified FTO electrode, prepared via a facile electrodeposition method, is investigated as a non-enzymatic glucose sensor under neutral conditions. The electrode exhibits a linear detection of glucose in the 0.1-8.2 mmol/L range with a detection limit of 67 μM, a sensitivity of 18.69 μA/mM.cm2, and a fast response time of less than 7 s under neutral conditions. Its stability is confirmed with both electrochemical experiments and characterization studies performed on the pristine and post-mortem electrode. We also conducted a comprehensive electrochemical analysis to elucidate the identity of the active site and the glucose oxidation mechanism on the Prussian blue surface.
Collapse
Affiliation(s)
- Ramadan Chalil Oglou
- UNAM - National Nanotechnology Research Center, Bilkent University, Ankara, 06800, Turkey
| | | | - Ekmel Ozbay
- NANOTAM - Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey; Department of Electrical and Electronics Engineering, Bilkent University, Ankara, 06800, Turkey; Department of Physics, Faculty of Science Bilkent University, 06800, Ankara, Turkey
| | - Ferdi Karadas
- UNAM - National Nanotechnology Research Center, Bilkent University, Ankara, 06800, Turkey; Department of Chemistry, Faculty of Science, Bilkent University, 06800, Ankara, Turkey.
| |
Collapse
|
136
|
Yue W, Kim ES, Zhu BH, Chen J, Liang JG, Kim NY. Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification. BIOSENSORS 2021; 11:bios11120508. [PMID: 34940265 PMCID: PMC8699625 DOI: 10.3390/bios11120508] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 12/01/2021] [Accepted: 12/07/2021] [Indexed: 05/10/2023]
Abstract
In this study, we propose a high-performance resonator-based biosensor for mediator-free glucose identification. The biosensor is characterized by an air-bridge capacitor and fabricated via integrated passive device technology on gallium arsenide (GaAs) substrate. The exterior design of the structure is a spiral inductor with the air-bridge providing a sensitive surface, whereas the internal capacitor improves indicator performance. The sensing relies on repolarization and rearrangement of surface molecules, which are excited by the dropped sample at the microcosmic level, and the resonance performance variation corresponds to the difference in glucose concentration at the macroscopic level. The air-bridge capacitor in the modeled RLC circuit serves as a bio-recognition element to glucose concentration (εglucoseC0), generating resonant frequency shifts at 0.874 GHz and 1.244 GHz for concentrations of 25 mg/dL and 300 mg/dL compared to DI water, respectively. The proposed biosensor exhibits excellent sensitivity at 1.38 MHz per mg/dL with a wide detection range for glucose concentrations of 25-300 mg/dL and a low detection limit of 24.59 mg/dL. Additionally, the frequency shift and concentration are highly linear with a coefficient of determination of 0.98823. The response time is less than 3 s. We performed multiple experiments to verify that the surface morphology reveals no deterioration and chemical binding, thus validating the reusability and reliability of the proposed biosensor.
Collapse
Affiliation(s)
- Wei Yue
- Radio Frequency Integrated Circuit (RFIC), Kwangwoon University, Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (W.Y.); (E.-S.K.); (B.-H.Z.); (J.C.)
| | - Eun-Seong Kim
- Radio Frequency Integrated Circuit (RFIC), Kwangwoon University, Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (W.Y.); (E.-S.K.); (B.-H.Z.); (J.C.)
| | - Bao-Hua Zhu
- Radio Frequency Integrated Circuit (RFIC), Kwangwoon University, Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (W.Y.); (E.-S.K.); (B.-H.Z.); (J.C.)
| | - Jian Chen
- Radio Frequency Integrated Circuit (RFIC), Kwangwoon University, Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (W.Y.); (E.-S.K.); (B.-H.Z.); (J.C.)
| | - Jun-Ge Liang
- Engineering Research Center of IoT Technology Applications (Ministry of Education), Department of Electronic Engineering, Jiangnan University, Wuxi 214122, China
- Correspondence: (J.-G.L.); (N.-Y.K.)
| | - Nam-Young Kim
- Radio Frequency Integrated Circuit (RFIC), Kwangwoon University, Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (W.Y.); (E.-S.K.); (B.-H.Z.); (J.C.)
- Correspondence: (J.-G.L.); (N.-Y.K.)
| |
Collapse
|
137
|
Nasrollahpour H, Khalilzadeh B, Naseri A, Sillanpää M, Chia CH. Homogeneous Electrochemiluminescence in the Sensors Game: What Have We Learned from Past Experiments? Anal Chem 2021; 94:349-365. [PMID: 34878242 DOI: 10.1021/acs.analchem.1c03909] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Hassan Nasrollahpour
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51664-14766, Iran
| | - Balal Khalilzadeh
- Stem Cell Research Center, Tabriz University of Medical Sciences, Tabriz 51664-14766, Iran
| | - Abdolhossein Naseri
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51664-14766, Iran
| | - Mika Sillanpää
- Environmental Engineering and Management Research Group, Ton Duc Thang University, 70000 Ho Chi Minh City, Vietnam.,Faculty of Environment and Labour Safety, Ton Duc Thang University, 70000 Ho Chi Minh City, Vietnam
| | - Chin Hua Chia
- Department of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Malaysia
| |
Collapse
|
138
|
Ying S, Chen C, Wang J, Lu C, Liu T, Kong Y, Yi FY. Synthesis and Applications of Prussian Blue and Its Analogues as Electrochemical Sensors. Chempluschem 2021; 86:1608-1622. [PMID: 34907675 DOI: 10.1002/cplu.202100423] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 11/15/2021] [Indexed: 12/23/2022]
Abstract
Prussian blue (PB) and its analogue (PBA) are a kind of representative cyanide-based coordination polymer. They have received enormous research interest and have shown promising applications in the electrochemical sensing field due to their excellent electrochemical activity and unique structural characteristics including open framework structure, high specific surface area, and adjustable metal active sites. In this review, we summarize the latest research progress of PB/PBA as an electrochemical sensor in detail from three aspects: fabrication strategy, synthesis method and electrochemical sensor application. For the fabrication strategy, we discussed different fabrication methods containing the combination of PBA and carbon materials, metal nanoparticles, polymers, etc., respectively, as well as their corresponding sensing mechanism for improving performance. We also presented the synthesis methods of PB/PBA materials in detail, such as: coprecipitation, hydrothermal and electrodeposition. In addition, the effects of different methods on the morphology, particle size and productivity of PB/PBA materials are also concluded. For the application of electrochemical sensors, the latest progress of such materials as electrochemical sensors for glucose, H2O2, toxic compounds, and biomolecules have been summarized. Finally, we conclude remaining challenges of PB/PBA-based materials as electrochemical sensors, and provide personal perspectives for future research in this field.
Collapse
Affiliation(s)
- Shuanglu Ying
- The School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang, 315211, P. R. China
| | - Chen Chen
- The School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang, 315211, P. R. China
| | - Jiang Wang
- The School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang, 315211, P. R. China
| | - Chunxiao Lu
- The School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang, 315211, P. R. China
| | - Tian Liu
- The School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang, 315211, P. R. China
| | - Yuxuan Kong
- The School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang, 315211, P. R. China
| | - Fei-Yan Yi
- The School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang, 315211, P. R. China
| |
Collapse
|
139
|
Nonenzymatic electrochemical sensors via Cu native oxides (CuNOx) for sweat glucose monitoring. SENSING AND BIO-SENSING RESEARCH 2021. [DOI: 10.1016/j.sbsr.2021.100453] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
140
|
Wang H, Sheng T, Zhao S, Zheng Y, Yu J, Zhang Y, Gu Z. Recent advances in transdermal sensors for glucose monitoring. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2021. [DOI: 10.1016/j.cobme.2021.100326] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
141
|
Yhobu Z, K. N. B, Achar G, Małecki JG, Keri RS, D. H. N, Budagumpi S. Glucose electrocatalysts derived from mono‐ or dicarbene coordinated nickel(II) complexes and their mesoporous carbon composites. Appl Organomet Chem 2021. [DOI: 10.1002/aoc.6446] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Zhoveta Yhobu
- Centre for Nano and Material Sciences Jain University Bangalore India
- Department of Chemistry, School of Applied Sciences REVA University Bangalore India
| | - Brinda K. N.
- Centre for Nano and Material Sciences Jain University Bangalore India
| | - Gautam Achar
- Centre for Nano and Material Sciences Jain University Bangalore India
| | | | - Rangappa S. Keri
- Centre for Nano and Material Sciences Jain University Bangalore India
| | - Nagaraju D. H.
- Department of Chemistry, School of Applied Sciences REVA University Bangalore India
| | | |
Collapse
|
142
|
Mazurków JM, Kusior A, Radecka M. Electrochemical Characterization of Modified Glassy Carbon Electrodes for Non-Enzymatic Glucose Sensors. SENSORS 2021; 21:s21237928. [PMID: 34883931 PMCID: PMC8659783 DOI: 10.3390/s21237928] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 11/17/2021] [Accepted: 11/24/2021] [Indexed: 01/07/2023]
Abstract
The diversity of materials proposed for non-enzymatic glucose detection and the lack of standardized protocols for assessing sensor performance have caused considerable confusion in the field. Therefore, methods for pre-evaluation of working electrodes, which will enable their conscious design, are currently intensively sought. Our approach involved comprehensive morphologic and structural characterization of copper sulfides as well as drop-casted suspensions based on three different polymers-cationic chitosan, anionic Nafion, and nonionic polyvinylpyrrolidone (PVP). For this purpose, scanning electron microscopy (SEM), X-ray diffraction (XRD), and Raman spectroscopy were applied. Subsequently, comparative studies of electrochemical properties of bare glassy carbon electrode (GCE), polymer- and copper sulfides/polymer-modified GCEs were performed using electrochemical impedance spectroscopy (EIS) and voltammetry. The results from EIS provided an explanation for the enhanced analytical performance of Cu-PVP/GCE over chitosan- and Nafion-based electrodes. Moreover, it was found that the pH of the electrolyte significantly affects the electrocatalytic behavior of copper sulfides, indicating the importance of OHads in the detection mechanism. Additionally, diffusion was denoted as a limiting step in the irreversible electrooxidation process that occurs in the proposed system.
Collapse
|
143
|
Non-Enzymatic Amperometric Glucose Screen-Printed Sensors Based on Copper and Copper Oxide Particles. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app112210830] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Non-enzymatic amperometric glucose sensors have gained much attention in the past decade because of the better chemical and thermal stability and biocompatibility compared to conventional sensors based on the use of biomolecules. This study focuses on a novel copper and copper oxide-based glucose sensor synthesized by an electrodeposition technique through a rigorous protocol which reports an excellent analytical performance due to its structure and its increased active area. In addition, the linear response range, detection limit and sensitivity were 0.5–5.0 mmol L−1, 0.002 mmol L−1, 904 μA mmol−1 L−1 cm−2, respectively. Results show a reliable electrode as it is chemically stable, exhibits rapid and excellent sensitivity, and it is not significantly affected by coexisting species present in the blood samples; furthermore, it reports a maximum relative standard deviation error (RSD) of 6%, and showed long operating life as the electrode was used for thousand measurements of 4.0 mmol L−1 glucose solution during three days.
Collapse
|
144
|
Sangsawang R, Buranachai C, Thavarungkul P, Kanatharana P, Jeerapan I. Cavitas electrochemical sensors for the direct determination of salivary thiocyanate levels. Mikrochim Acta 2021; 188:415. [PMID: 34755233 DOI: 10.1007/s00604-021-05067-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 10/20/2021] [Indexed: 11/24/2022]
Abstract
Noninvasive diagnosis using salivary samples to detect thiocyanate provides vital information on individual health. This article demonstrates the first example of a wearable sensing device to noninvasively assess thiocyanate levels. The customized screen-printed electrode system is integrated into a form of a mouthguard squarewave-voltammetric sensor toward the convenient and fast detection of the salivary biomarker within 15 s. The sensor with a protective film to mitigate the effect of biofouling offers high sensitivity and selectivity toward the detection of thiocyanate ions. Partial least square regression is applied to analyze the high-order squarewave-voltammetric data over the applied potential range of 0-1.75 V vs Ag/AgCl and quantify the thiocyanate concentration in a complex matrix. The mouthguard sensor operating under physiological conditions can monitor a wide range of thiocyanate (up to 11 mM) with a low detection limit of 30 µM. The demonstration introduces a unique approach, that obviates the requirement for blood sampling, to study thiocyanate levels of healthy people, cigarette smokers, or people with other health conditions. It is envisioned that the new cavitas device possesses a substantial promise for diverse biomedical diagnosis applications.
Collapse
Affiliation(s)
- Rachanon Sangsawang
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Chongdee Buranachai
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.,Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.,Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Panote Thavarungkul
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.,Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.,Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Proespichaya Kanatharana
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.,Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.,Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Itthipon Jeerapan
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand. .,Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand. .,Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
145
|
A nanoscale Nd-based metal-organic framework electrochemical sensor for rapid detection of Rhodamine B. J SOLID STATE CHEM 2021. [DOI: 10.1016/j.jssc.2021.122508] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
146
|
Theerthagiri J, Lee SJ, Karuppasamy K, Park J, Yu Y, Kumari MLA, Chandrasekaran S, Kim HS, Choi MY. Fabrication strategies and surface tuning of hierarchical gold nanostructures for electrochemical detection and removal of toxic pollutants. JOURNAL OF HAZARDOUS MATERIALS 2021; 420:126648. [PMID: 34329090 DOI: 10.1016/j.jhazmat.2021.126648] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 07/10/2021] [Accepted: 07/12/2021] [Indexed: 05/20/2023]
Abstract
The intensive research on the synthesis and characterization of gold (Au) nanostructures has been extensively documented over the last decades. These investigations allow the researchers to understand the relationships between the intrinsic properties of Au nanostructures such as particle size, shape, morphology, and composition to synthesize the Au nano/hybrid nanostructures with novel physicochemical properties. By tuning the properties above, these nanostructures are extensively employed to detect and remove trace amounts of toxic pollutants from the environment. This review attempts to document the achievements and current progress in Au-based nanostructures, general synthetic and fabrication strategies and their utilization in electrochemical sensing and environmental remediation applications. Additionally, the applications of Au nanostructures (e.g., as adsorbents, sensing platforms, catalysts, and electrodes) and advancements in the field of electrochemical sensing of different target analytes (e.g., proteins, nucleic acids, heavy metals, small molecules, and antigens) are summarized. The literature survey concludes the existing methods for the detection of toxic contaminants at various concentration levels. Finally, the existing challenges and future research directions on electrochemical sensing and degradation of toxic contaminants using Au nanostructures are defined.
Collapse
Affiliation(s)
- Jayaraman Theerthagiri
- Core-Facility Center for Photochemistry & Nanomaterials, Department of Chemistry (BK21 FOUR), Research Institute of Natural Sciences, Gyeongsang National University, Jinju 52828, South Korea
| | - Seung Jun Lee
- Core-Facility Center for Photochemistry & Nanomaterials, Department of Chemistry (BK21 FOUR), Research Institute of Natural Sciences, Gyeongsang National University, Jinju 52828, South Korea
| | - K Karuppasamy
- Division of Electronics and Electrical Engineering, Dongguk University-Seoul, Seoul 04620, Republic of Korea
| | - Juhyeon Park
- Core-Facility Center for Photochemistry & Nanomaterials, Department of Chemistry (BK21 FOUR), Research Institute of Natural Sciences, Gyeongsang National University, Jinju 52828, South Korea
| | - Yiseul Yu
- Core-Facility Center for Photochemistry & Nanomaterials, Department of Chemistry (BK21 FOUR), Research Institute of Natural Sciences, Gyeongsang National University, Jinju 52828, South Korea
| | - M L Aruna Kumari
- Department of Chemistry, M.S. Ramaiah College of Arts, Science and Commerce, Bengaluru 560054, India
| | - Sivaraman Chandrasekaran
- Center of Excellence in Environmental Studies, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Hyun-Seok Kim
- Division of Electronics and Electrical Engineering, Dongguk University-Seoul, Seoul 04620, Republic of Korea
| | - Myong Yong Choi
- Core-Facility Center for Photochemistry & Nanomaterials, Department of Chemistry (BK21 FOUR), Research Institute of Natural Sciences, Gyeongsang National University, Jinju 52828, South Korea.
| |
Collapse
|
147
|
Muzyka K, Xu G. Laser‐induced Graphene in Facts, Numbers, and Notes in View of Electroanalytical Applications: A Review. ELECTROANAL 2021. [DOI: 10.1002/elan.202100425] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Kateryna Muzyka
- Laboratory of Analytical Optochemotronics Department of Biomedical Engineering Kharkiv National University of RadioElectronics Kharkiv 61166 Ukraine
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry Changchun Institute of Applied Chemistry Chinese Academy of Sciences 5625 Renmin Street Changchun Jilin 130022 PR China
| |
Collapse
|
148
|
Gorle DB, Ponnada S, Kiai MS, Nair KK, Nowduri A, Swart HC, Ang EH, Nanda KK. Review on recent progress in metal-organic framework-based materials for fabricating electrochemical glucose sensors. J Mater Chem B 2021; 9:7927-7954. [PMID: 34612291 DOI: 10.1039/d1tb01403j] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Diabetes is a type of disease that threatens human health, which can be diagnosed based on the level of glucose in the blood. Recently, various MOF-based materials have been developed as efficient electrochemical glucose sensors because of their tunable pore channels, large specific surface area well dispersed metallic active sites, etc. In this review, the significance of glucose detection and the advantages of MOF-based materials for this application are primarily discussed. Then, the application of MOF-based materials can be categorized into two types of glucose sensors: enzymatic biosensors and non-enzymatic sensors. Finally, insights into the current research challenges and future breakthrough possibilities regarding electrochemical glucose sensors are considered.
Collapse
Affiliation(s)
- Demudu Babu Gorle
- Materials Research Centre, Indian Institute of Science, Bangalore-560012, India.
| | - Srikanth Ponnada
- Department of Engineering Chemistry, Andhra University College of Engineering, Andhra University, Visakhapatnam-530003, India
| | - Maryam Sadat Kiai
- Nano-Science and Nano-Engineering Program, Graduate School of Science, Engineering and Technology, Istanbul Technical University, Istanbul-34469, Turkey
| | - Kishore Kumar Nair
- Department of Physics, University of Free state, Bloemfontein-9300, South Africa
| | - Annapurna Nowduri
- Department of Engineering Chemistry, Andhra University College of Engineering, Andhra University, Visakhapatnam-530003, India
| | - Hendrik C Swart
- Department of Physics, University of Free state, Bloemfontein-9300, South Africa
| | - Edison Huixiang Ang
- Natural Sciences and Science Education, National Institute of Education Singapore, Nanyang Technological University Singapore, Nanyang Walk-637616, Singapore
| | - Karuna Kar Nanda
- Materials Research Centre, Indian Institute of Science, Bangalore-560012, India.
| |
Collapse
|
149
|
Diouri O, Cigler M, Vettoretti M, Mader JK, Choudhary P, Renard E. Hypoglycaemia detection and prediction techniques: A systematic review on the latest developments. Diabetes Metab Res Rev 2021; 37:e3449. [PMID: 33763974 PMCID: PMC8519027 DOI: 10.1002/dmrr.3449] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 12/08/2020] [Accepted: 01/28/2021] [Indexed: 02/06/2023]
Abstract
The main objective of diabetes control is to correct hyperglycaemia while avoiding hypoglycaemia, especially in insulin-treated patients. Fear of hypoglycaemia is a hurdle to effective correction of hyperglycaemia because it promotes under-dosing of insulin. Strategies to minimise hypoglycaemia include education and training for improved hypoglycaemia awareness and the development of technologies to allow their early detection and thus minimise their occurrence. Patients with impaired hypoglycaemia awareness would benefit the most from these technologies. The purpose of this systematic review is to review currently available or in-development technologies that support detection of hypoglycaemia or hypoglycaemia risk, and identify gaps in the research. Nanomaterial use in sensors is a promising strategy to increase the accuracy of continuous glucose monitoring devices for low glucose values. Hypoglycaemia is associated with changes on vital signs, so electrocardiogram and encephalogram could also be used to detect hypoglycaemia. Accuracy improvements through multivariable measures can make already marketed galvanic skin response devices a good noninvasive alternative. Breath volatile organic compounds can be detected by dogs and devices and alert patients at hypoglycaemia onset, while near-infrared spectroscopy can also be used as a hypoglycaemia alarms. Finally, one of the main directions of research are deep learning algorithms to analyse continuous glucose monitoring data and provide earlier and more accurate prediction of hypoglycaemia. Current developments for early identification of hypoglycaemia risk combine improvements of available 'needle-type' enzymatic glucose sensors and noninvasive alternatives. Patient usability will be essential to demonstrate to allow their implementation for daily use in diabetes management.
Collapse
Affiliation(s)
- Omar Diouri
- Department of Endocrinology, Diabetes, NutritionMontpellier University HospitalMontpellierFrance
- Department of PhysiologyInstitute of Functional Genomics, CNRS, INSERMUniversity of MontpellierMontpellierFrance
| | - Monika Cigler
- Division of Endocrinology and DiabetologyDepartment of Internal MedicineMedical University of GrazGrazAustria
| | | | - Julia K. Mader
- Division of Endocrinology and DiabetologyDepartment of Internal MedicineMedical University of GrazGrazAustria
| | - Pratik Choudhary
- Department of Diabetes and Nutritional SciencesKing's College LondonLondonUK
- Diabetes Research CentreUniversity of LeicesterLeicesterUK
| | - Eric Renard
- Department of Endocrinology, Diabetes, NutritionMontpellier University HospitalMontpellierFrance
- Department of PhysiologyInstitute of Functional Genomics, CNRS, INSERMUniversity of MontpellierMontpellierFrance
| | | |
Collapse
|
150
|
Olejnik A, Karczewski J, Dołęga A, Siuzdak K, Cenian A, Grochowska K. Simple synthesis route for fabrication of protective photo-crosslinked poly(zwitterionic) membranes for application in non-enzymatic glucose sensing. J Biomed Mater Res B Appl Biomater 2021; 110:679-690. [PMID: 34592065 DOI: 10.1002/jbm.b.34946] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 09/03/2021] [Accepted: 09/09/2021] [Indexed: 01/20/2023]
Abstract
This work focuses on the fabrication of non-enzymatic glucose sensing materials based on laser-formed Au nanoparticles embedded in Ti-textured substrates. Those materials possess good catalytic activity toward glucose oxidation in 0.1 × phosphate buffered saline as well as resistance to some interferants, such as ascorbic acid, urea, and glycine. The electrodes are further coated with three different polymers, that is, Nafion, photo-crosslinked poly(zwitterions) based on sulfobetaine methacrylate, and a hybrid membrane consisting of both polymers. Both the optimal integrity of the material and its catalytic activity toward glucose oxidation were maintained by the hybrid membranes with a large excess of poly(zwitterions) (mass ratio 20:1). The chemical structures of the as-formed membranes are confirmed by Fourier transform infrared spectroscopy. Due to the zwitterionic nature of the coating, the electrodes are resistant to biofouling and maintain electrochemical activity toward glucose for 4 days. Moreover, due to the synergistic effect of both Nafion and poly(zwitterions), the interference from the two compounds, namely, from acetylsalicylic acid and acetaminophen, was diminished. Besides the presence of polymer membranes, the electrode possesses a sensitivity of 36.8 μA cm-2 mM-1 in the linear range of 0.4-12 mM, while the limit of detection was estimated to be 23 μM. Finally, the electrodes are stable, and their response is not altered even by 1,000 bending cycles.
Collapse
Affiliation(s)
- Adrian Olejnik
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Gdańsk, Poland.,Department of Metrology and Optoelectronics, Faculty of Electronics, Telecommunications and Informatics, Gdańsk University of Technology, Gdańsk, Poland
| | - Jakub Karczewski
- Faculty of Applied Physics and Mathematics, Gdańsk University of Technology, Gdańsk, Poland
| | - Anna Dołęga
- Department of Inorganic Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| | - Katarzyna Siuzdak
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Gdańsk, Poland
| | - Adam Cenian
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Gdańsk, Poland
| | - Katarzyna Grochowska
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Gdańsk, Poland
| |
Collapse
|