101
|
Shafranska O, Tokarev V, Voronov A, Bednarska O, Voronov S. Graft polymerization from a silica surface initiated by adsorbed peroxide macroinitiators. I. Adsorption and structure of the adsorbed layer of peroxide macroinitiators on a silica surface. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2005; 21:3459-3469. [PMID: 15807588 DOI: 10.1021/la0482453] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The adsorption features of two peroxide macroinitiators (PMIs) with various functionalities from their semi-dilute solutions on the silica surface were thoroughly investigated in the present work. These investigations include the study of the adsorption kinetics of PMI in diverse solvents and a detailed examination of the adsorbed layer structure with the aid of ellipsometry, scanning force microscopy (SFM), and contact angle measurements. Rearrangements of PMI macromolecules at the solid surface are supposed to be the main reason for the appearance of extremes on the kinetic curves and, besides, have a more pronounceable effect on adsorption rate than their diffusion rate to the surface even at the initial stage of the process. Both island-like and densely packed structures of absorbed layers were revealed by combining contact angle measurements and SFM. Surprisingly, even in the case when saturation of the adsorbed layer is reached, PMI does not completely occupy the substrate surface which is at least particularly reachable for the wetting liquids. PMIs adsorbed at the solid surface are intended for the formation of tethered polymer "brushes" via the initiation of "grafting from" polymerization.
Collapse
Affiliation(s)
- Olena Shafranska
- Lviv Polytechnic National University, 12 Bandera Str., UA-79013 Lviv, Ukraine
| | | | | | | | | |
Collapse
|
102
|
Ruckenstein E, Li ZF. Surface modification and functionalization through the self-assembled monolayer and graft polymerization. Adv Colloid Interface Sci 2005; 113:43-63. [PMID: 15763238 DOI: 10.1016/j.cis.2004.07.009] [Citation(s) in RCA: 210] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2004] [Accepted: 07/27/2004] [Indexed: 11/22/2022]
Abstract
The modification of a surface at the molecular level with precise control of the building blocks generates an integrated molecular system. This field has progressed rapidly in recent years through the use of self-assembled monolayer (SAM) interfaces. Recent developments on surface-initiated chemical reactions, functionalization, and graft polymerization on SAM interfaces are emphasized in the present review. A number of surface modifications by grafting are reviewed. The grafting of polyaniline on a glass surface, previously modified with a silane self-assembled monolayer (SAM), is examined in detail for both planar and 3-D systems, such as fibers, nanoparticles, and even polymer patterned surfaces. We also discuss the graft polymerization of water-soluble polymers on the surface of silicon nanoparticles, which generate stable aqueous colloidal solutions and have numerous applications. Finally, we compare and review some surface-modification techniques on the surfaces of polymers, such as two-solvent entrapment, polymer blending, and chemical grafting, which improve their biocompatibility.
Collapse
Affiliation(s)
- E Ruckenstein
- Department of Chemical and Biological Engineering, State University of New York at Buffalo, Buffalo, NY 14260, USA.
| | | |
Collapse
|
103
|
Surface free energy changes of stainless steel after one atmospheric pressure plasma treatment. KOREAN J CHEM ENG 2004. [DOI: 10.1007/bf02719497] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
104
|
Zhao L, Wang J, Neoh KG, Kang ET. Electroactive polymer patterns with metal incorporation on a polymeric substrate. POLYM ENG SCI 2004. [DOI: 10.1002/pen.20210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
105
|
Tu CY, Chen CP, Wang YC, Li CL, Tsai HA, Lee KR, Lai JY. Acrylamide plasma-induced polymerization onto expanded poly(tetrafluoroethylene) membrane for aqueous alcohol mixture vapor permeation separation. Eur Polym J 2004. [DOI: 10.1016/j.eurpolymj.2004.02.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
106
|
Cheng Z, Teoh SH. Surface modification of ultra thin poly (ε-caprolactone) films using acrylic acid and collagen. Biomaterials 2004; 25:1991-2001. [PMID: 14741613 DOI: 10.1016/j.biomaterials.2003.08.038] [Citation(s) in RCA: 228] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Poly (epsilon-caprolactone) (PCL) has been used as a bioresorbable polymer in numerous medical devices as well as for tissue engineering applications. Its main advantage is its biocompatibility and slow degradation rate. PCL surface, however, is hydrophobic and cell-biomaterial interaction is not the best. We attempt for the first time to modify an ultra thin PCL surface with collagen. The PCL film was prepared using solvent casting and biaxial stretching technique developed in our laboratory. This biaxial stretching produced an ultra thin PCL 3-7 microm thick, ideal for membrane tissue engineering applications. The PCL film was pretreated using Argon plasma, and then UV polymerized with acrylic acid (AAc). Collagen immobilization was then carried out. The modified film surface was characterized by Fourier Transform Infrared (FT-IR) and X-ray Photoelectron Spectroscopy (XPS). Water contact angles were also measured to evaluate the hydrophilicity of the modified surface. Results showed that the hydrophilicity of the surface has improved significantly after surface modification. The water contact angle dropped from 66 degrees to 32 degrees. Atomic Force Microscopy (AFM) showed an increase in roughness of the film. A change from 46 to 60 nm in the surface morphology was also observed. The effect of cells attachment on the PCL film was studied. Human dermal fibroblasts and myoblasts attachment and proliferation were improved remarkably on the modified surface. The films showed excellent cell attachment and proliferation rate.
Collapse
Affiliation(s)
- Ziyuan Cheng
- Department of Mechanical Engineering, Centre for Biomedical Materials Applications and Technology (BIOMAT), National University of Singapore, Kent Ridge, Singapore 119260, Singapore
| | | |
Collapse
|
107
|
Chen Y, Kang ET, Neoh KG, Zhang Y, Tan KL. Oxidative graft polymerization of aniline on Si(100) surface modified by plasma polymerization of glycidyl methacrylate. POLYM ENG SCI 2004. [DOI: 10.1002/pen.11022] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
108
|
|
109
|
Abidi N, Hequet E. Cotton fabric graft copolymerization using microwave plasma. I. Universal attenuated total reflectance-FTIR study. J Appl Polym Sci 2004. [DOI: 10.1002/app.20442] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
110
|
Ng CM, Oei HP, Wu SY, Zhang MC, Kang ET, Neoh KG. Surface modification of plasma-pretreated high density polyethylene films by graft copolymerization for adhesion improvement with evaporated copper. POLYM ENG SCI 2004. [DOI: 10.1002/pen.11232] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
111
|
Hsiue GH, Lu PL, Chen JC. Multienzyme-immobilized modified polypropylene membrane for an amperometric creatinine biosensor. J Appl Polym Sci 2004. [DOI: 10.1002/app.20229] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
112
|
Choee JH, Lee SJ, Lee YM, Rhee JM, Lee HB, Khang G. Proliferation rate of fibroblast cells on polyethylene surfaces with wettability gradient. J Appl Polym Sci 2004. [DOI: 10.1002/app.20048] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
113
|
Cen L, Neoh KG, Kang ET. Antibacterial activity of cloth functionalized with N-alkylated poly(4-vinylpyridine). ACTA ACUST UNITED AC 2004; 71:70-80. [PMID: 15368256 DOI: 10.1002/jbm.a.30125] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A simple technique was developed to functionalize the surface of commercial cotton cloth with bactericidal polycationic groups. The cloth was first graft copolymerized with 4-vinylpyridine (4VP) and subsequently derivatized with hexylbromide via the quaternization of the grafted pyridine groups into pyridinium groups. X-ray photoelectron spectroscopy (XPS) was used to characterize the cotton cloth after each surface functionalization step. The pyridinium groups introduced on the substrate surface exhibited a high bacterial killing efficiency as shown by airborne and waterborne Escherichia coli (E. coli) assays, as well as a test to measure the number of viable E. coli cells in suspension upon contact with the cloth. This antibacterial property is preserved even after the cloth is subjected to prolonged weathering under UV irradiation and water spray. Wild-type bacteria were also cultured from soil and used to verify the antibacterial potential of the functionalized cloth. The inhibition of biofilm formation on the functionalized cloth was observed even with the inoculation of high concentrations of microorganisms. The success of the present surface functionalization technique as applied to cloth is a promising development, as since cloth is a common material having wide applications.
Collapse
Affiliation(s)
- L Cen
- Department of Chemical and Biomolecular Engineering, National University of Singapore, Kent Ridge, Singapore 119260
| | | | | |
Collapse
|
114
|
Li Y, Neoh KG, Cen L, Kang ET. Physicochemical and blood compatibility characterization of polypyrrole surface functionalized with heparin. Biotechnol Bioeng 2003; 84:305-13. [PMID: 12968284 DOI: 10.1002/bit.10757] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A surface modification technique was developed for the covalent immobilization of heparin onto electrically conductive polypyrrole (PPY) film. The PPY film was first graft copolymerized with poly(ethylene glycol) methacrylate (PEGMA) and then activated with cyanuric chloride (CC). Heparin was then immobilized onto the film through the reaction between the chloride groups of CC and the amine and/or hydroxyl groups of heparin. X-ray photoelectron spectroscopy (XPS) was used to characterize the surface-modified film after each stage. The biocompatibility of the surface-modified PPY was evaluated using plasma recalcification time (PRT) and platelet adhesion. After surface modification, the film had improved wettability while retaining significant electrical conductivity. With immobilized heparin, platelet adhesion and platelet activation on PPY film was significantly suppressed, and the PRT was significantly prolonged. Electrical stimulation also plays a positive role in decreasing platelet adhesion and increasing PRT on pristine and surface-modified PPY films.
Collapse
Affiliation(s)
- Yali Li
- Department of Chemical and Environmental Engineering, National University of Singapore, Kent Ridge, Singapore 119260, Republic of Singapore
| | | | | | | |
Collapse
|
115
|
Yuan YL, Ai F, Zhang J, Zang XB, Shen J, Lin SC. Grafting sulfobetaine monomer onto the segmented poly(ether-urethane) surface to improve hemocompatibility. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2003; 13:1081-92. [PMID: 12484485 DOI: 10.1163/156856202320813800] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Polyurethanes are widely used as blood-contacting biomaterials, due to their good biocompatibility and mechanical properties. Nevertheless, their blood compatibility is still not adequate for more demanding applications. Surface modification is an effective way to improve the hemocompatibility for biomaterials. The purpose of the present study was to synthesize a novel nonthrombogenic biomaterial by modifying the surface of polyurethane. Ozonization was used to introduce active peroxide groups onto the segmented poly(ether-urethane) (SPEU) film surface and graft polymerization of N,N'-dimethyl (methacryloyloxyethyl) ammonium propanesulfonate (DMAPS), a sulfobetaine structure, onto the ozone-activated SPEU surface was conducted. The SPEU-g-PDMAPS film was characterized by ATR-FTIR, XPS, and contact angle measurements. ATR-FTIR and XPS confirmed the graft polymerization. The grafted film possessed a relatively hydrophilic surface, as revealed by contact angle measurement. The blood compatibility of the grafted films was evaluated by a platelet-rich plasma (PRP) adhesion study and scanning electron microscopy, using SPEU film as the reference. No platelet adhesion was observed for the grafted films incubated with PRP at 37 degrees C for 60 and 180 min. This new sulfobetaine structure grafted biomaterial might have potential for biomedical applications.
Collapse
Affiliation(s)
- Y L Yuan
- Center of Research on Surface and Interface Chemical Engineering and Technology, Nanjing University, Nanjing, 210093, People's Republic of China
| | | | | | | | | | | |
Collapse
|
116
|
Yamada K, Yamane H, Kumada K, Tanabe S, Kajiyama T. Plasma-graft polymerization of a monomer with double bonds onto the surface of carbon fiber and its adhesion to a vinyl ester resin. J Appl Polym Sci 2003. [DOI: 10.1002/app.12897] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
117
|
Sugiyama K, Shiraishi K, Sono K. Characterization and application of polypropylene films modified with stimuli-sensitive copolymers with an Ar-plasma postpolymerization technique. J Appl Polym Sci 2003. [DOI: 10.1002/app.12604] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
118
|
Huang J, Wang X, Chen X, Yu X. Temperature-sensitive membranes prepared by the plasma-induced graft polymerization ofN-Isopropylacrylamide into porous polyethylene membranes. J Appl Polym Sci 2003. [DOI: 10.1002/app.12562] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
119
|
Yuan Y, Zhang J, Ai F, Yuan J, Zhou J, Shen J, Lin S. Surface modification of SPEU films by ozone induced graft copolymerization to improve hemocompatibility. Colloids Surf B Biointerfaces 2003. [DOI: 10.1016/s0927-7765(02)00210-2] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
120
|
Seok Kang J, Hoon Lee S, Huh H, Kie Shim J, Moo Lee Y. Preparation of chlorinated poly(vinyl chloride)-g-poly(N-vinyl-2-pyrrolidinone) membranes and their water permeation properties. J Appl Polym Sci 2003. [DOI: 10.1002/app.12148] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
121
|
Vohrer U, Hegemann D, Oehr C. XPS, AES, and AFM as tools for study of optimized plasma functionalization. Anal Bioanal Chem 2003; 375:929-34. [PMID: 12707763 DOI: 10.1007/s00216-003-1750-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2002] [Revised: 12/04/2002] [Accepted: 12/06/2002] [Indexed: 12/01/2022]
Abstract
The plasma-based surface modification of polymer materials with desirable bulk properties is a useful way to obtain polymers with tailor-made surface properties. This is necessary because the surface properties of most engineering polymers in use today are less then optimum for many applications. New functionalities such as biocompatibility, adhesion, special functional groups as well as lubricative, friction and wear-and-tear properties are demanded. By optimization of the process parameters during a low pressure plasma treatment, most of these requirements can be fulfilled. A specific functionalization with, e.g., carboxyl, amino, epoxy or hydroxyl groups as well as the generation of ultra thin layers with those functionalities is possible. The most challenging problem is not only to find parameters which do not lead to a fragmentation of the monomeric structure, but moreover the adhesion of the thin films to the substrates must overcome a stability test without delamination. To optimize plasma processes, with their great variety of parameters influencing the obtained surface properties, several surface analytical techniques are indispensable. XPS, AES as well as AFM are helpful tools to characterize the modified sample surfaces and consequently optimize the set of parameters for the glow discharge treatment. With XPS the retention of the monomer structure can be controlled. AES depth profiling clarifies the elemental composition of gradient layers, necessary for a good adhesion of scratch-resistant coatings. AFM visualizes the surface morphology which is important for, e.g., the friction properties of plasma-coated substrates.
Collapse
Affiliation(s)
- U Vohrer
- Fraunhofer Institute for Interfacial Engineering and Biotechnology (FhIGB), Nobelstrasse 12, 70569 Stuttgart, Germany.
| | | | | |
Collapse
|
122
|
Kwon OH, Nho YC, Chen J. Surface modification of polypropylene film by radiation-induced grafting and its blood compatibility. J Appl Polym Sci 2003. [DOI: 10.1002/app.11832] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
123
|
Lee SJ, Khang G, Lee YM, Lee HB. The effect of surface wettability on induction and growth of neurites from the PC-12 cell on a polymer surface. J Colloid Interface Sci 2003; 259:228-35. [PMID: 16256501 DOI: 10.1016/s0021-9797(02)00163-7] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2002] [Accepted: 11/20/2002] [Indexed: 10/27/2022]
Abstract
Surface properties of polymeric devices that are used to regenerate nervous damage are a point to be considered for axon regeneration in nerve system. In our previous studies, we prepared a wettability gradient on polyethylene (PE) surfaces using a corona discharge treatment from a knife-type electrode whose power increases gradually along the sample length. The PE surfaces were oxidized gradually with increasing power. The effect of surface wettability on the different types of cells has an important role for cell adhesion and proliferation. The purpose of this study is to investigate neurite formation on polymer surfaces with different wettability. Induction and growth of neurites from the rat pheochromocytoma (PC-12) cells attached on the polymer surfaces with different hydrophilicity were investigated using the wettability gradient PE surfaces prepared by a corona discharge treatment. Neurites were investigated for number and length of neurites in terms of surface wettability. It was observed that neurite formation of PC-12 cells was increased more onto the positions with moderate hydrophilicity of the wettability gradient surface than onto the more hydrophobic or hydrophilic positions. From those results, it could be assumed that initial adhesion of PC-12 cells was caused by more calf serum (CS) protein than nerve growth factor (NGF), whereas the neurite formation of PC-12 cells was caused by more NGF than CS protein. It follows from what has been said thus far that PC-12 cells are a differentiated neuronal phenotype with a long neurite at around the position 2.5 cm (water contact angle of about 55 deg). In conclusion, surface wettability plays an important role for neurite formation on the polymer surfaces for axon regeneration.
Collapse
Affiliation(s)
- Sang Jin Lee
- School of Chemical Engineering, Hanyang University, 17 Haengdang Dong, Seongdong Ku, Seoul 133-791, South Korea
| | | | | | | |
Collapse
|
124
|
Yang G, Zhang Y, Lee K, Kang E, Neoh K. Thermal imidization of poly(pyromellitic dianhydride-4,4′-oxydianiline) precursors on fluoropolymers modified by surface graft-copolymerization with glycidyl methacrylate. J Fluor Chem 2003. [DOI: 10.1016/s0022-1139(02)00238-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
125
|
Ying L, Yin C, Zhuo RX, Leong KW, Mao HQ, Kang ET, Neoh KG. Immobilization of galactose ligands on acrylic acid graft-copolymerized poly(ethylene terephthalate) film and its application to hepatocyte culture. Biomacromolecules 2003; 4:157-65. [PMID: 12523861 DOI: 10.1021/bm025676w] [Citation(s) in RCA: 125] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Surface modification of argon-plasma-pretreated poly(ethylene terephthalate) (PET) films via UV-induced graft copolymerization with acrylic acid (AAc) was carried out. Galactosylated surfaces were then obtained by coupling a galactose derivative (1-O-(6'-aminohexyl)-D-galactopyranoside) to the AAc graft chains with the aid of a water-soluble carbodiimide (WSC) and N-hydroxysulfosuccinimide (sulfo-NHS). The modified PET films were characterized by X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and water contact-angle measurements. The galactosylated PET films were used as substrates for hepatocyte culture. The effects of surface carboxyl group concentration on the extent of galactose ligand immobilization, the extent of hepatocyte attachment, and the surface morphology were investigated. The amount of the galactose ligands immobilized on the PET surface increased with the AAc polymer graft concentration. AFM images revealed that the surface roughness of the PET film increased after graft copolymerization with AAc, but did not change appreciably with the subsequent immobilization of the galactose ligands. At the surface carboxyl group concentration of about 0.56 micromol/cm(2) or galactose ligand concentration of about 0.51 micromol/cm(2), the hepatocyte culture on the galactosylated surface exhibited the optimum concentration and physiological functions and formed aggregates or spheroids after just 1 day of culture. The albumin and urea synthesis functions of these hepatocytes were comparable to or higher than those of the hepatocytes cultured on the collagen-modified PET substrates.
Collapse
Affiliation(s)
- Lei Ying
- Department of Chemical Engineering, National University of Singapore, Kent Ridge, Singapore 119260, Republic of Singapore
| | | | | | | | | | | | | |
Collapse
|
126
|
Prissanaroon W, Brack N, Pigram PJ, Liesegang J. Electropolymerization of DBSA-doped polypyrrole films on PTFE via an electroless copper interlayer. SURF INTERFACE ANAL 2003. [DOI: 10.1002/sia.1634] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
127
|
Desai S, Bodas D, Patil KR, Patole M, Singh RP. Tailor-made functional surfaces: potential elastomeric biomaterials I. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2003; 14:1323-38. [PMID: 14870937 DOI: 10.1163/156856203322599671] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
In the present investigation, different functional monomers, like hydroxyethyl methacrylate, acrylic acid, N-vinyl pyrrolidone and glycidyl methacrylate, have been grafted onto the surface of EPDM film (approx. 200 microm) using simultaneous photo-grafting (lambda > or = 290 nm) and cold plasma-grafting techniques, to alter the surface properties, such as hydrophilicity and, therefore, biocompatibility. Here, we have carried out simultaneous plasma-grafting, unlike the conventional post plasma-grafting. The effect of different surface grafting techniques on the degree of surface modification and resultant biocompatibility has been investigated. The chemical changes on the polymer backbone are followed from the results of attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectroscopy and X-ray photoelectron spectroscopy (XPS), which shows the peaks corresponding to the functional groups of the monomers grafted onto the film surface. The morphology of the modified surfaces was investigated using scanning electron microscopy (SEM) technique. The induced hydrophilicity and resultant cell compatibility were followed from the water contact angle measurements and in vitro human carcinoma cell adhesion/proliferation tests, respectively. All the grafted samples exhibited variable cell compatibilities depending upon the type of monomer and their degree of grafting; however, always better than the neat samples. Hydroxyethyl methacrylate and acrylic acid showed exceptionally high cell compatibility in terms of cell adhesion and proliferation.
Collapse
Affiliation(s)
- Shrojal Desai
- Polymer Chemistry Division, National Chemical Laboratory, Pune 41108, India
| | | | | | | | | |
Collapse
|
128
|
Gupta B, Anjum N. Plasma and Radiation-Induced Graft Modification of Polymers for Biomedical Applications. RADIATION EFFECTS ON POLYMERS FOR BIOLOGICAL USE 2003. [DOI: 10.1007/3-540-45668-6_2] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
129
|
|
130
|
|
131
|
Hydrophilic modification of polyethersulfone membranes by low temperature plasma-induced graft polymerization. J Memb Sci 2002. [DOI: 10.1016/s0376-7388(02)00352-6] [Citation(s) in RCA: 203] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
132
|
Kusumocahyo SP, Kanamori T, Iwatsubo T, Sumaru K, Shinbo T. Development of polyion complex membranes based on cellulose acetate modified by oxygen plasma treatment for pervaporation. J Memb Sci 2002. [DOI: 10.1016/s0376-7388(02)00264-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
133
|
Steffens GCM, Nothdurft L, Buse G, Thissen H, Höcker H, Klee D. High density binding of proteins and peptides to poly(D,L-lactide) grafted with polyacrylic acid. Biomaterials 2002; 23:3523-31. [PMID: 12099298 DOI: 10.1016/s0142-9612(02)00091-1] [Citation(s) in RCA: 87] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The use of graft polymers for the functionalisation of biomaterial surfaces is already widespread. We investigated the adsorptive and covalent binding of a variety of proteins and peptides to poly(D,L-lactide) grafted with polyacrylic acid. Covalent attachment was achieved through coupling of amino groups of the protein/peptide to the carboxyl groups of the graft polymer by using a water-soluble carbodiimide and N-hydroxysuccinimide. Binding densities were determined by automated amino acid analysis after acid hydrolysis of both the poly(D,L-lactide) and the adsorbed and covalently bound proteins. Experiments in the absence and presence of the coupling reagents allow to discriminate between adsorptive and covalent binding. Although the adsorptivc binding is quite substantial in absolute terms, the amount of adsorbed protein is relatively low as compared to the total amount of bound protein. Total binding densities of 20-30 microg/cm2 can easily be achieved. Depending on the concentration and on the properties of the proteins and peptides, between 5% and 80% of the totally bound protein may be physically adsorbed. Densities expressed in molecules/10 nm2 vary from 0.5 molecule fibronectin to 2,000 laminin-peptide molecules: their binding densities clearly correlate with their respective molecular masses. Obviously, the binding densities are governed by their individual three-dimensional space requirements rather than the density of the available carboxyl groups. From the number of carboxyl groups/10 nm2 (18,000-30,000 COOH/10 nm2) the average length of the acrylic acid graft polymer molecules was estimated. Based on the assumption that about 10 copolymer chains can be accommodated on 10 nm2, the average length of the polymer chains, which corresponds to the thickness of the graft phase, is estimated to be 0.5-1 microm. The organisation of the proteins and peptides within the polyacrylic acid phase was further investigated by experiments in which a protein (BSA) and a peptide (Val-Lys) were allowed to react in either a singular, a consecutive or a simultaneous way. Together with XPS and IR-ATR surface characterisation experiments a three-dimensional picture of the arrangement of the immobilised proteins and peptides within the graft polymer phase emerges.
Collapse
Affiliation(s)
- G C M Steffens
- Department of Biochemistry, Institut für Biochemie, Universitätsklinikum RWTH, Aachen, Germany.
| | | | | | | | | | | |
Collapse
|
134
|
Yang G, Kang E, Neoh K. Thermal and electroless deposition of copper on poly(tetrafluoroethylene-co-hexafluoropropylene) films modified by surface graft copolymerization. ACTA ACUST UNITED AC 2002. [DOI: 10.1109/tadvp.2002.805316] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
135
|
Ito T, Hioki T, Yamaguchi T, Shinbo T, Nakao SI, Kimura S. Development of a molecular recognition ion gating membrane and estimation of its pore size control. J Am Chem Soc 2002; 124:7840-6. [PMID: 12083938 DOI: 10.1021/ja012648x] [Citation(s) in RCA: 127] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We have fabricated a molecular recognition ion gating membrane. This synthetic membrane spontaneously opens and closes its pores in response to specific solvated ions. In addition to this switching function, we found that this membrane could control its pore size in response to a known concentration of a specific ion. The membrane was prepared by plasma graft copolymerization, which filled the pores of porous polyethylene film with a copolymer of NIPAM (N-isopropylacrylamide) and BCAm (benzo[18]crown-6-acrylamide). NIPAM is well-known to have an LCST (lower critical solution temperature), at which its volume changes dramatically in water. The crown receptor of the BCAm traps a specific ion, and causes a shift in the LCST. Therefore, selectively responding to either K(+) or Ba(2+), the grafted copolymer swelled and shrank in the pores at a constant temperature between two LCSTs. The solution flux in the absence of Ba(2+) decreased by about 2 orders of magnitude over a solution flux containing Ba(2+). The pore size was estimated by the filtration of aqueous dextran solutions with various solute sizes. This revealed that the membrane changed its pore size between 5 and 27 nm in response to the Ba(2+) concentration changes. No such change was observed for Ca(2+) solutions. Furthermore, this pore size change occurred uniformly in all pores, as a clear cut-off value for a solute size that could pass through pores was always present. This membrane may be useful not only as a molecular recognition ion gate, but also as a device for spontaneously controlling the permeation flux and solute size.
Collapse
Affiliation(s)
- Taichi Ito
- Department of Chemical System Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, 113-8656 Tokyo, Japan
| | | | | | | | | | | |
Collapse
|
136
|
Li ZF, Ruckenstein E. Strong Adhesion and Smooth Conductive Surface via Graft Polymerization of Aniline on a Modified Glass Fiber Surface. J Colloid Interface Sci 2002; 251:343-9. [PMID: 16290739 DOI: 10.1006/jcis.2002.8413] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2002] [Accepted: 04/01/2002] [Indexed: 11/22/2022]
Abstract
The goal of this paper is to prepare surface-conductive glass fibers. The fibers were first hydroxylated, after which they were reacted with 3-bromopropyltrichlorosilane to form a bromopropylsilane monolayer, which was further reacted with aniline to substitute the bromine atoms. The surface-bound aniline molecules were used as active sites for the graft polymerization of polyaniline (PANI). The composition, structure and the morphology of the modified glass fiber surface were examined by X-ray photoelectron spectroscopy, scanning electron microscopy, and Fourier transform infrared spectroscopy. The method generated a smooth and homogenous thin layer of PANI on the surface of the glass fiber with a surface conductivity of about 6 S/cm, hence larger than the usual value ( approximately 1 S/cm) of the bulk polyaniline.
Collapse
Affiliation(s)
- Z F Li
- Department of Chemical Engineering, State University of New York at Buffalo, Buffalo, New York 14260, USA
| | | |
Collapse
|
137
|
Suh TS, Joo CK, Kim YC, Lee MS, Lee HK, Choe BY, Chun HJ. Surface modification of polymethyl methacrylate intraocular lenses with the mixture of acrylic acid and acrylamide via plasma-induced graft copolymerization. J Appl Polym Sci 2002. [DOI: 10.1002/app.10870] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
138
|
Zhang F, Kang ET, Neoh KG, Huang W. Modification of gold surface by grafting of poly(ethylene glycol) for reduction in protein adsorption and platelet adhesion. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2002; 12:515-31. [PMID: 11469782 DOI: 10.1163/156856201300194252] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Gold surfaces were first treated in an alkanethiol solution to form self-assembled monolayers (SAMs). The thiolated Au surface was then subjected to Ar plasma pretreatment, followed by air exposure and UV-induced graft polymerization of poly(ethylene glycol) methacrylate (PEGMA) macromonomer. In comparison with the 3-mercaptopropionic acid-2-ethylhexyl ester (MPAEE) SAM, the (3-mercaptoproply)trimethoxysilane (MPTMS) SAM on Au exhibited higher stability under the conditions of Ar plasma pretreatment. The graft concentration of the PEGMA polymer on SAM-modified Au surface increased with increasing PEGMA macromonomer concentration and UV-graft polymerization time. The modified-Au surfaces were characterized by X-ray spectroscopy (XPS), atomic force microscopy (AFM), and water contact angle measurement. The Au surface with a high concentration of grafted PEGMA polymer could completely repel protein adsorption and platelet adhesion.
Collapse
Affiliation(s)
- F Zhang
- Department of Chemical Engineering, National University of Singapore, Kent Ridge Crescent
| | | | | | | |
Collapse
|
139
|
Irwan GS, Kuroda SI, Kubota H, Kondo T. Photografting of methacrylic acid on polyethylene film: Effect of mixed solvents consisting of water and organic solvent. J Appl Polym Sci 2002. [DOI: 10.1002/app.10235] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
140
|
The effect of maleic anhydride grafting on the flame retardation of plasma pretreated polyethylene. Polym Degrad Stab 2002. [DOI: 10.1016/s0141-3910(02)00025-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
141
|
Ko YG, Kim YH, Park KD, Lee HJ, Lee WK, Park HD, Kim SH, Lee GS, Ahn DJ. Immobilization of poly(ethylene glycol) or its sulfonate onto polymer surfaces by ozone oxidation. Biomaterials 2001; 22:2115-23. [PMID: 11432591 DOI: 10.1016/s0142-9612(00)00400-2] [Citation(s) in RCA: 103] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A novel surface modification method has been developed to improve biocompatibility of polymeric biomaterials. This approach involves ozonation and then followed by graft polymerization with acrylates containing PEG, sulfonated PEG or by coupling of PEG derivatives. All the reactions were confirmed by ATR FT-IR and ESCA. The degree of ozonation measured by the iodide method was dependent on the ozone permeability of the polymers used. Surface hydrophilicity was investigated by measuring the contact angles. Ozonation itself yielded a slight increase in hydrophilicity and a decrease in platelet adhesion, but PEG immobilization showed a significant effect on surface hydrophilicity and platelet adhesion to confirm well-known PEG's passivity which minimize the adhesion of blood components on polymer surfaces. Both graft polymerization and coupling were effective for PU. In contrast, only grafting gave enough yields for PMMA and silicone. Platelet adhesion results demonstrated that all PEG modified surfaces adsorbed lower platelet adhesion than untreated or ozonated ones. Polymers coupled with sulfonated PEG exhibited the lowest platelet adhesion when compared with control and PEG coupled ones by virtue of the synergistic effect of non-adhesive PEG and negatively charged SO3 groups. This PEG or sulfonated PEG immobilization technology using ozonation is relatively simple for introducing uniform surface modification and therefore very useful for practical application of blood contacting medical devices.
Collapse
Affiliation(s)
- Y G Ko
- Biomaterials Research Center, Korea Institute of Science and Technology, Cheongryang, Seoul, South Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
142
|
Abstract
The blood-contacting surface, mainly composed of polycarbonate, of the Gyro C1E3 pump was modified using plasma glow discharge to introduce a carboxyl functional group, coated with a base layer of polyethyleneimine as a linker, and coupled with heparin by multi-ionic binding to enhance blood compatibility. A relative surface content of 3.7% sulfur, which demonstrated heparin immobilization on the polycarbonate substrate, was observed on x-ray photoelectron spectroscopy, and a initial bioactivity of approximately 88.5 +/- 7.3 mIU/cm2 was obtained by the chromogenic method for antifactor Xa assay. Furthermore, in vitro observation of platelet and fibrin adherence using bovine blood under dynamic flow conditions for 6 h revealed that the multi-ionically heparinized Gyro C1E3 had significantly stronger antithrombogenecity than the noncoated original type which was evaluated as a good hemocompatible blood pump for clinical use. Not only the Gyro C1E3 but also the ionically heparin-coated Gyro pump are expected to be thromboresistant in clinical use.
Collapse
Affiliation(s)
- K Muramatsu
- Research and Development Department, Bioceram Division, Kyocera Corporation, 10-1, Kawai, Gamo-cho, Shiga 529-1595, Japan.
| | | | | |
Collapse
|
143
|
Zou X, Kang E, Neoh K, Cui C, Lim T. Surface modification of poly(tetrafluoroethylene) films by plasma polymerization of glycidyl methacrylate for adhesion enhancement with evaporated copper. POLYMER 2001. [DOI: 10.1016/s0032-3861(01)00113-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
144
|
Zhang F, Kang ET, Neoh KG, Wang P, Tan KL. Surface modification of stainless steel by grafting of poly(ethylene glycol) for reduction in protein adsorption. Biomaterials 2001; 22:1541-8. [PMID: 11374453 DOI: 10.1016/s0142-9612(00)00310-0] [Citation(s) in RCA: 123] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The surface of stainless steel was first modified by the silane coupling agent (SCA), (3-mercaptopropyl)trimethoxysilane. The silanized stainless-steel surface (SCA-SS surface) was subsequently activated by argon plasma and then subjected to UV-induced graft polymerization of poly(ethylene glycol)methacrylate (PEGMA). The chemical structures and composition of the pristine, silane-treated, plasma-treated and PEGMA graft-polymerized stainless-steel coupon surfaces were characterized by X-ray photoelectron spectroscopy (XPS) and attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy. The graft polymerization of PEGMA onto the plasma-pretreated SCA-SS surface was studied with different argon plasma pretreatment time, macromonomer concentration, and UV graft polymerization time. In general, a brief plasma pretreatment, high PEGMA concentration, and long UV graft polymerization time readily resulted in a high graft concentration. The PEGMA graft-polymerized stainless-steel coupon (PEGMA-g-SCA-SS) with a high graft concentration, and thus a high PEG content, was found to be very effective in preventing bovine serum albumin and gamma-globulin adsorption.
Collapse
Affiliation(s)
- F Zhang
- Department of Chemical Engineering, National University of Singapore, Crescent
| | | | | | | | | |
Collapse
|
145
|
Ng SW, Neoh KG, Sampanthar JT, Kang ET, Tan KL. Conversion of Polyaniline from Insulating to Conducting State in Aqueous Viologen Solutions. J Phys Chem B 2001. [DOI: 10.1021/jp002669y] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- S. W. Ng
- Department of Chemical and Environmental Engineering, National University of Singapore, Kent Ridge, Singapore 119260
| | - K. G. Neoh
- Department of Chemical and Environmental Engineering, National University of Singapore, Kent Ridge, Singapore 119260
| | - J. T. Sampanthar
- Department of Chemical and Environmental Engineering, National University of Singapore, Kent Ridge, Singapore 119260
| | - E. T. Kang
- Department of Chemical and Environmental Engineering, National University of Singapore, Kent Ridge, Singapore 119260
| | - K. L. Tan
- Department of Physics, National University of Singapore, Kent Ridge, Singapore 119260
| |
Collapse
|
146
|
Chen Y, E. T. Kang,* and, Neoh KG, Tan KL. Oxidative Graft Polymerization of Aniline on Modified Si(100) Surface. Macromolecules 2001. [DOI: 10.1021/ma0008589] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Yongjun Chen
- Department of Chemical Engineering, National University of Singapore, Kent Ridge, Singapore 119260
| | - E. T. Kang,* and
- Department of Chemical Engineering, National University of Singapore, Kent Ridge, Singapore 119260
| | - K. G. Neoh
- Department of Chemical Engineering, National University of Singapore, Kent Ridge, Singapore 119260
| | - K. L. Tan
- Department of Physics, National University of Singapore, Kent Ridge, Singapore 119260
| |
Collapse
|
147
|
|
148
|
Guan J, Gao C, Feng L, Sheng J. Surface photo-grafting of polyurethane with 2-hydroxyethyl acrylate for promotion of human endothelial cell adhesion and growth. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2001; 11:523-36. [PMID: 10896045 DOI: 10.1163/156856200743841] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Cytocompatible polyurethane (PU) surface was prepared by photo-grafting 2-hydroxyethyl acrylate (HEA) onto the membrane surface. Graft polymerization was conducted by combining the use of the photo-oxidation and irradiation grafting. PU membrane was photo-oxidized to introduce the hydroperoxide groups onto the surface, then the membrane, immersed previously in monomer solution, was irradiated under UV light. The ATR-FTIR spectra, element spectroscopy for chemical analysis (ESCA), scanning electron microscopy (SEM) and water contact angle characterized the grafted copolymers and verified the occurrence of graft polymerization. The results showed that UV irradiation could realize the graft polymerization effectively and the grafting was confined within the surface layer. The grafted membrane showed minimal surface morphology. Human umbilical vein endothelial (HUVE) cells were seeded on the grafted surface. The performance of the surface in cell attachment and growth correlated with the oxygen content and mainly the carbonyl content on the surface. Cells were spread more extensively and grew faster on the surface with a higher oxygen content.
Collapse
Affiliation(s)
- J Guan
- Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, People's Republic of China
| | | | | | | |
Collapse
|
149
|
Gao J, Lei J, Su Z, Zhang B, Wang J. Photografting of Maleic Anhydride on Low Density Polyethylene Powder in the Vapor Phase. Polym J 2001. [DOI: 10.1295/polymj.33.147] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
150
|
Gupta B, Hilborn JG, Bisson I, Frey P. Plasma-induced graft polymerization of acrylic acid onto poly(ethylene terephthalate) films. J Appl Polym Sci 2001. [DOI: 10.1002/app.1749] [Citation(s) in RCA: 100] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|