101
|
Soleymani L, Li F. Mechanistic Challenges and Advantages of Biosensor Miniaturization into the Nanoscale. ACS Sens 2017; 2:458-467. [PMID: 28723192 DOI: 10.1021/acssensors.7b00069] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Over the past few decades, there has been tremendous interest in developing biosensing systems that combine high sensitivity and specificity with rapid sample-to-answer times, portability, low-cost operation, and ease-of-use. Miniaturizing the biosensor dimensions into the nanoscale has been identified as a strategy for addressing the functional requirements of point-of-care and wearable biosensors. However, it is important to consider that decreasing the critical dimensions of biosensing elements impacts the two most important performance metrics of biosensors: limit-of-detection and response time. Miniaturization into the nanoscale enhances signal-to-noise-ratio by increasing the signal density (signal/geometric surface area) and reducing background signals. However, there is a trade-off between the enhanced signal transduction efficiency and the longer time it takes to collect target analytes on sensor surfaces due to the increase in mass transport times. By carefully considering the signal transduction mechanisms and reaction-transport kinetics governing different classes of biosensors, it is possible to develop structure-level and device-level strategies for leveraging miniaturization toward creating biosensors that combine low limit-of-detection with rapid response times.
Collapse
Affiliation(s)
- Leyla Soleymani
- Department
of Engineering Physics, School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Feng Li
- Department
of Chemistry, Brock University, 1812 Sir Isaac Brock Way, St. Catharines, Ontario L2S 3A1, Canada
| |
Collapse
|
102
|
Wu MYC, Hsu MY, Chen SJ, Hwang DK, Yen TH, Cheng CM. Point-of-Care Detection Devices for Food Safety Monitoring: Proactive Disease Prevention. Trends Biotechnol 2017; 35:288-300. [PMID: 28089198 DOI: 10.1016/j.tibtech.2016.12.005] [Citation(s) in RCA: 68] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Revised: 11/27/2016] [Accepted: 12/12/2016] [Indexed: 11/22/2022]
Abstract
Food safety has become an increasingly significant public concern in both developed and under-developed nations around the world; it increases morbidity, mortality, human suffering, and economic burden. This Opinion focuses on (i) examining the influence of pathogens and chemicals (e.g., food additives and pesticide residue) on food-borne illnesses, (ii) summarizing food hazards that are present in Asia, and (iii) summarizing the array of current point-of-care (POC) detection devices that have potential applications in food safety monitoring. In addition, we provide insight into global healthcare issues in both developing and under-developed nations with a focus on bridging the gap between food safety issues in the public sector (associated with relevant clinical cases) and the use of POC detection devices for food safety monitoring.
Collapse
Affiliation(s)
| | - Min-Yen Hsu
- Department of Ophthalmology, Taichung Veterans General Hospital, Taichung 407, Taiwan; School of Medicine, Chung Shan Medical University, Taichung 402, Taiwan
| | - Shih-Jen Chen
- Department of Ophthalmology, School of Medicine, National Yang-Ming University, Taipei 112, Taiwan
| | - De-Kuang Hwang
- Department of Ophthalmology, School of Medicine, National Yang-Ming University, Taipei 112, Taiwan
| | - Tzung-Hai Yen
- Poison Center, Department of Nephrology, Chang Gung Memorial Hospital and Chang Gung University, Linkou 333, Taiwan; Kidney Research Center, Chang Gung Memorial Hospital, Linkou 333, Taiwan; Center for Tissue Engineering, Chang Gung Memorial Hospital, Linkou 333, Taiwan.
| | - Chao-Min Cheng
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu 300, Taiwan.
| |
Collapse
|
103
|
Yamada K, Shibata H, Suzuki K, Citterio D. Toward practical application of paper-based microfluidics for medical diagnostics: state-of-the-art and challenges. LAB ON A CHIP 2017; 17:1206-1249. [PMID: 28251200 DOI: 10.1039/c6lc01577h] [Citation(s) in RCA: 276] [Impact Index Per Article: 34.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) have emerged as a promising diagnostic platform a decade ago. In contrast to highly active academic developments, their entry into real-life applications is still very limited. This discrepancy is attributed to the gap between research developments and their practical utility, particularly in the aspects of operational simplicity, long-term stability of devices, and associated equipment. On the basis of these backgrounds, this review attempts to: 1) identify the reasons for success of paper-based devices already in the market, 2) describe the current status and remaining issues of μPADs in terms of operational complexity, signal interpretation approaches, and storage stability, and 3) discuss the possibility of mass production based on established manufacturing technologies. Finally, the state-of-the-art in commercialisation of μPADs is discussed, and the "upgrades" required from a laboratory-based prototype to an end user device are demonstrated on a specific example.
Collapse
Affiliation(s)
- Kentaro Yamada
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.
| | - Hiroyuki Shibata
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.
| | - Koji Suzuki
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.
| | - Daniel Citterio
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.
| |
Collapse
|
104
|
Morbioli GG, Mazzu-Nascimento T, Stockton AM, Carrilho E. Technical aspects and challenges of colorimetric detection with microfluidic paper-based analytical devices (μPADs) - A review. Anal Chim Acta 2017; 970:1-22. [PMID: 28433054 DOI: 10.1016/j.aca.2017.03.037] [Citation(s) in RCA: 251] [Impact Index Per Article: 31.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Revised: 02/14/2017] [Accepted: 03/17/2017] [Indexed: 12/29/2022]
Abstract
Paper-based devices are a leading alternative among the main analytical tools for point-of-care testing, due to their portability, low-cost, and ease-of-use. Colorimetric readouts are the most common method of detection in these microfluidic devices, enabling qualitative, semi-quantitative and fully quantitative analysis of multiple analytes. There is a multitude of ways to obtain a colorimetric output in such devices, including nanoparticles, dyes, redox and pH indicators, and each has unique drawbacks and benefits. There are also multiple variables that impact the analysis of colorimetric reactions in microfluidic paper-based systems, including color homogeneity, image capture methods, and the data handling itself. Here, we present a critical review of recent developments and challenges of colorimetric detection on microfluidic paper-based analytical devices (μPADs), and present thoughts and insights towards future perspectives in the area to improve the use of colorimetric readouts in conjunction with μPADs.
Collapse
Affiliation(s)
- Giorgio Gianini Morbioli
- Instituto de Química de São Carlos, Universidade de São Paulo, Av. Trabalhador São-carlense, 400, 13566-590 São Carlos, SP, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13083-970 Campinas, SP, Brazil; School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Thiago Mazzu-Nascimento
- Instituto de Química de São Carlos, Universidade de São Paulo, Av. Trabalhador São-carlense, 400, 13566-590 São Carlos, SP, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13083-970 Campinas, SP, Brazil
| | - Amanda M Stockton
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Emanuel Carrilho
- Instituto de Química de São Carlos, Universidade de São Paulo, Av. Trabalhador São-carlense, 400, 13566-590 São Carlos, SP, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13083-970 Campinas, SP, Brazil.
| |
Collapse
|
105
|
Rapid and Low-Cost CRP Measurement by Integrating a Paper-Based Microfluidic Immunoassay with Smartphone (CRP-Chip). SENSORS 2017; 17:s17040684. [PMID: 28346363 PMCID: PMC5419797 DOI: 10.3390/s17040684] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Revised: 03/14/2017] [Accepted: 03/23/2017] [Indexed: 01/05/2023]
Abstract
Traditional diagnostic tests for chronic diseases are expensive and require a specialized laboratory, therefore limiting their use for point-of-care (PoC) testing. To address this gap, we developed a method for rapid and low-cost C-reactive protein (CRP) detection from blood by integrating a paper-based microfluidic immunoassay with a smartphone (CRP-Chip). We chose CRP for this initial development because it is a strong biomarker of prognosis in chronic heart and kidney disease. The microfluidic immunoassay is realized by lateral flow and gold nanoparticle-based colorimetric detection of the target protein. The test image signal is acquired and analyzed using a commercial smartphone with an attached microlens and a 3D-printed chip–phone interface. The CRP-Chip was validated for detecting CRP in blood samples from chronic kidney disease patients and healthy subjects. The linear detection range of the CRP-Chip is up to 2 μg/mL and the detection limit is 54 ng/mL. The CRP-Chip test result yields high reproducibility and is consistent with the standard ELISA kit. A single CRP-Chip can perform the test in triplicate on a single chip within 15 min for less than 50 US cents of material cost. This CRP-Chip with attractive features of low-cost, fast test speed, and integrated easy operation with smartphones has the potential to enable future clinical PoC chronic disease diagnosis and risk stratification by parallel measurements of a panel of protein biomarkers.
Collapse
|
106
|
Jiang H, Wu D, Song L, Yuan Q, Ge S, Min X, Xia N, Qian S, Qiu X. A Smartphone-Based Genotyping Method for Hepatitis B Virus at Point-of-Care Settings. SLAS Technol 2016; 22:122-129. [PMID: 27899699 DOI: 10.1177/2211068216680163] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
We reported a rapid, convenient, and easy-to-use genotyping method for hepatitis B virus (HBV) based on the smartphone at point-of-care (POC) settings. To perform HBV genotyping especially for genotypes A, B, C, and D, a smartphone is used to image and analyze a one-step immunoassay lateral flow strip functionalized with genotype-specific monoclonal antibodies (mAbs) on multiple capture lines. A light-emitting diode (LED) positioned on the top of the lateral flow strip is used to shine the multiple capture lines for excitation. Fluorescence detection is obtained with a smartphone whose camera is used to take the fluorescent images. An intelligent algorithm is developed to first identify each capture line from the fluorescent image and then determine the HBV genotype based on a genotyping model. Based on the pattern of the detection signal from different samples, a custom HBV genotyping model is developed. Custom application software running on a smartphone is developed with Java to collect and analyze the fluorescent image, display the genotyping result, and transmit it if necessary. Compared with the existing methods with nucleic acid analysis, more convenient, instant, and efficient HBV genotyping with significantly lower cost and a simpler procedure can be obtained with the developed smartphone POC HBV genotyping method.
Collapse
Affiliation(s)
- Huiqin Jiang
- 1 Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China
| | - Di Wu
- 1 Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China
| | - Liuwei Song
- 2 National Institute of Diagnostics and Vaccine Development in Infectious Diseases, Xiamen University, Xiamen, Fujian, China
| | - Quan Yuan
- 2 National Institute of Diagnostics and Vaccine Development in Infectious Diseases, Xiamen University, Xiamen, Fujian, China
| | - Shengxiang Ge
- 2 National Institute of Diagnostics and Vaccine Development in Infectious Diseases, Xiamen University, Xiamen, Fujian, China
| | - Xiaoping Min
- 2 National Institute of Diagnostics and Vaccine Development in Infectious Diseases, Xiamen University, Xiamen, Fujian, China
| | - Ningshao Xia
- 2 National Institute of Diagnostics and Vaccine Development in Infectious Diseases, Xiamen University, Xiamen, Fujian, China
| | - Shizhi Qian
- 3 Institute of Micro/Nanotechnology, Old Dominion University, Norfolk, VA, USA
| | - Xianbo Qiu
- 1 Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China
| |
Collapse
|
107
|
Nychas GJE, Panagou EZ, Mohareb F. Novel approaches for food safety management and communication. Curr Opin Food Sci 2016. [DOI: 10.1016/j.cofs.2016.06.005] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
108
|
Li X, Niu Y, Chen Y, Wu D, Yi L, Qiu X. Microfluidic Paper-Based Sample Concentration Using Ion Concentration Polarization with Smartphone Detection. MICROMACHINES 2016; 7:mi7110199. [PMID: 30404372 PMCID: PMC6189865 DOI: 10.3390/mi7110199] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Revised: 10/29/2016] [Accepted: 11/01/2016] [Indexed: 01/15/2023]
Abstract
A simple method for microfluidic paper-based sample concentration using ion concentration polarization (ICP) with smartphone detection is developed. The concise and low-cost microfluidic paper-based ICP analytical device, which consists of a black backing layer, a nitrocellulose membrane, and two absorbent pads, is fabricated with the simple lamination method which is widely used for lateral flow strips. Sample concentration on the nitrocellulose membrane is monitored in real time by a smartphone whose camera is used to collect the fluorescence images from the ICP device. A custom image processing algorithm running on the smartphone is used to track the concentrated sample and obtain its fluorescence signal intensity for quantitative analysis. Two different methods for Nafion coating are evaluated and their performances are compared. The characteristics of the ICP analytical device especially with intentionally adjusted physical properties are fully evaluated to optimize its performance as well as to extend its potential applications. Experimental results show that significant concentration enhancement with fluorescence dye sample is obtained with the developed ICP device when a fast depletion of fluorescent dye is observed. The platform based on the simply laminated ICP device with smartphone detection is desired for point-of-care testing in settings with poor resources.
Collapse
Affiliation(s)
- Xue Li
- Institute of Microfluidic Chip Development in Biomedical Engineering, State Key Laboratory of Organic-Inorganic Composites, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Yanan Niu
- Institute of Microfluidic Chip Development in Biomedical Engineering, State Key Laboratory of Organic-Inorganic Composites, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Yunyi Chen
- Institute of Microfluidic Chip Development in Biomedical Engineering, State Key Laboratory of Organic-Inorganic Composites, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Di Wu
- Institute of Microfluidic Chip Development in Biomedical Engineering, State Key Laboratory of Organic-Inorganic Composites, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Long Yi
- Institute of Microfluidic Chip Development in Biomedical Engineering, State Key Laboratory of Organic-Inorganic Composites, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Xianbo Qiu
- Institute of Microfluidic Chip Development in Biomedical Engineering, State Key Laboratory of Organic-Inorganic Composites, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
| |
Collapse
|
109
|
Choi G, Song D, Shrestha S, Miao J, Cui L, Guan W. A field-deployable mobile molecular diagnostic system for malaria at the point of need. LAB ON A CHIP 2016; 16:4341-4349. [PMID: 27722377 PMCID: PMC5089926 DOI: 10.1039/c6lc01078d] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
In response to the urgent need of a field-deployable and highly sensitive malaria diagnosis, we developed a standalone, "sample-in-answer-out" molecular diagnostic system (AnyMDx) to enable quantitative molecular analysis of blood-borne malaria in low resource areas. The system consists of a durable battery-powered analyzer and a disposable microfluidic compact disc loaded with reagents ready for use. A low power thermal module and a novel fluorescence-sensing module are integrated into the analyzer for real-time monitoring of loop-mediated isothermal nucleic acid amplification (LAMP) of target parasite DNA. With 10 μL of raw blood sample, the AnyMDx system automates the nucleic acid sample preparation and subsequent LAMP and real-time detection. Under laboratory conditions with whole-blood samples spiked with cultured Plasmodium falciparum, we achieved a detection limit of ∼0.6 parasite per μL, much lower than those for the conventional microscopy and rapid diagnostic tests (∼50-100 parasites per μL). The turnaround time from sample to answer is less than 40 minutes. The AnyMDx is user-friendly requiring minimal technological training. The analyzer and the disposable reagent compact discs are cost-effective, making AnyMDx a potential tool for malaria molecular diagnosis under field settings for malaria elimination.
Collapse
Affiliation(s)
- Gihoon Choi
- Department of Electrical Engineering, Pennsylvania State University, University Park, 16802, USA.
| | - Daniel Song
- Department of Biomedical Engineering, Pennsylvania State University, University Park, 16802, USA
| | - Sony Shrestha
- Department of Entomology, Pennsylvania State University, University Park, 16802, USA
| | - Jun Miao
- Department of Entomology, Pennsylvania State University, University Park, 16802, USA
| | - Liwang Cui
- Department of Entomology, Pennsylvania State University, University Park, 16802, USA
| | - Weihua Guan
- Department of Electrical Engineering, Pennsylvania State University, University Park, 16802, USA. and Department of Biomedical Engineering, Pennsylvania State University, University Park, 16802, USA
| |
Collapse
|
110
|
Plevniak K, Campbell M, Myers T, Hodges A, He M. 3D printed auto-mixing chip enables rapid smartphone diagnosis of anemia. BIOMICROFLUIDICS 2016; 10:054113. [PMID: 27733894 PMCID: PMC5055529 DOI: 10.1063/1.4964499] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2016] [Accepted: 09/26/2016] [Indexed: 05/06/2023]
Abstract
Clinical diagnosis requiring central facilities and site visits can be burdensome for patients in resource-limited or rural areas. Therefore, development of a low-cost test that utilizes smartphone data collection and transmission would beneficially enable disease self-management and point-of-care (POC) diagnosis. In this paper, we introduce a low-cost iPOC3D diagnostic strategy which integrates 3D design and printing of microfluidic POC device with smartphone-based disease diagnosis in one process as a stand-alone system, offering strong adaptability for establishing diagnostic capacity in resource-limited areas and low-income countries. We employ smartphone output (AutoCAD 360 app) and readout (color-scale analytical app written in-house) functionalities for rapid 3D printing of microfluidic auto-mixers and colorimetric detection of blood hemoglobin levels. The auto-mixing of reagents with blood via capillary force has been demonstrated in 1 second without the requirement of external pumps. We employed this iPOC3D system for point-of-care diagnosis of anemia using a training set of patients (nanemia = 16 and nhealthy = 6), which showed consistent measurements of blood hemoglobin levels (a.u.c. = 0.97) and comparable diagnostic sensitivity and specificity, compared with standard clinical hematology analyzer. Capable of 3D fabrication flexibility and smartphone compatibility, this work presents a novel diagnostic strategy for advancing personalized medicine and mobile healthcare.
Collapse
Affiliation(s)
- Kimberly Plevniak
- Department of Biological and Agricultural Engineering, Kansas State University , Manhattan, Kansas 66506, USA
| | - Matthew Campbell
- Advanced Manufacturing Institute, Kansas State University , Manhattan, Kansas 66506, USA
| | - Timothy Myers
- Department of Science and Mathematics, MidAmerica Nazarene University , Olathe, Kansas 66062, USA
| | - Abby Hodges
- Department of Science and Mathematics, MidAmerica Nazarene University , Olathe, Kansas 66062, USA
| | | |
Collapse
|
111
|
Boyd-Moss M, Baratchi S, Di Venere M, Khoshmanesh K. Self-contained microfluidic systems: a review. LAB ON A CHIP 2016; 16:3177-92. [PMID: 27425637 DOI: 10.1039/c6lc00712k] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Microfluidic systems enable rapid diagnosis, screening and monitoring of diseases and health conditions using small amounts of biological samples and reagents. Despite these remarkable features, conventional microfluidic systems rely on bulky expensive external equipment, which hinders their utility as powerful analysis tools outside of research laboratories. 'Self-contained' microfluidic systems, which contain all necessary components to facilitate a complete assay, have been developed to address this limitation. In this review, we provide an in-depth overview of self-contained microfluidic systems. We categorise these systems based on their operating mechanisms into three major groups: passive, hand-powered and active. Several examples are provided to discuss the structure, capabilities and shortcomings of each group. In particular, we discuss the self-contained microfluidic systems enabled by active mechanisms, due to their unique capability for running multi-step and highly controllable diagnostic assays. Integration of self-contained microfluidic systems with the image acquisition and processing capabilities of smartphones, especially those equipped with accessory optical components, enables highly sensitive and quantitative assays, which are discussed. Finally, the future trends and possible solutions to expand the versatility of self-contained, stand-alone microfluidic platforms are outlined.
Collapse
Affiliation(s)
| | - Sara Baratchi
- School of Health & Biomedical Sciences, RMIT University, Melbourne, Victoria, Australia.
| | - Martina Di Venere
- School of Civil & Industrial Engineering, Sapienza University, Rome, Italy
| | | |
Collapse
|
112
|
Phillips RH, Jain R, Browning Y, Shah R, Kauffman P, Dinh D, Lutz BR. Flow control using audio tones in resonant microfluidic networks: towards cell-phone controlled lab-on-a-chip devices. LAB ON A CHIP 2016; 16:3260-7. [PMID: 27416111 DOI: 10.1039/c6lc00738d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Fluid control remains a challenge in development of portable lab-on-a-chip devices. Here, we show that microfluidic networks driven by single-frequency audio tones create resonant oscillating flow that is predicted by equivalent electrical circuit models. We fabricated microfluidic devices with fluidic resistors (R), inductors (L), and capacitors (C) to create RLC networks with band-pass resonance in the audible frequency range available on portable audio devices. Microfluidic devices were fabricated from laser-cut adhesive plastic, and a "buzzer" was glued to a diaphragm (capacitor) to integrate the actuator on the device. The AC flowrate magnitude was measured by imaging oscillation of bead tracers to allow direct comparison to the RLC circuit model across the frequency range. We present a systematic build-up from single-channel systems to multi-channel (3-channel) networks, and show that RLC circuit models predict complex frequency-dependent interactions within multi-channel networks. Finally, we show that adding flow rectifying valves to the network creates pumps that can be driven by amplified and non-amplified audio tones from common audio devices (iPod and iPhone). This work shows that RLC circuit models predict resonant flow responses in multi-channel fluidic networks as a step towards microfluidic devices controlled by audio tones.
Collapse
Affiliation(s)
- Reid H Phillips
- Department of Bioengineering, University of Washington, Box 355061, Foege N530N, 3720 15th Ave NE, Seattle, WA 98195, USA.
| | - Rahil Jain
- Department of Electrical Engineering, University of Washington, Seattle, WA 98195, USA
| | - Yoni Browning
- Department of Bioengineering, University of Washington, Box 355061, Foege N530N, 3720 15th Ave NE, Seattle, WA 98195, USA.
| | - Rachana Shah
- Department of Bioengineering, University of Washington, Box 355061, Foege N530N, 3720 15th Ave NE, Seattle, WA 98195, USA.
| | - Peter Kauffman
- Department of Bioengineering, University of Washington, Box 355061, Foege N530N, 3720 15th Ave NE, Seattle, WA 98195, USA.
| | - Doan Dinh
- Department of Bioengineering, University of Washington, Box 355061, Foege N530N, 3720 15th Ave NE, Seattle, WA 98195, USA.
| | - Barry R Lutz
- Department of Bioengineering, University of Washington, Box 355061, Foege N530N, 3720 15th Ave NE, Seattle, WA 98195, USA.
| |
Collapse
|
113
|
Fu Q, Wu Z, Xu F, Li X, Yao C, Xu M, Sheng L, Yu S, Tang Y. A portable smart phone-based plasmonic nanosensor readout platform that measures transmitted light intensities of nanosubstrates using an ambient light sensor. LAB ON A CHIP 2016; 16:1927-33. [PMID: 27137512 DOI: 10.1039/c6lc00083e] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Plasmonic nanosensors may be used as tools for diagnostic testing in the field of medicine. However, quantification of plasmonic nanosensors often requires complex and bulky readout instruments. Here, we report the development of a portable smart phone-based plasmonic nanosensor readout platform (PNRP) for accurate quantification of plasmonic nanosensors. This device operates by transmitting excitation light from a LED through a nanosubstrate and measuring the intensity of the transmitted light using the ambient light sensor of a smart phone. The device is a cylinder with a diameter of 14 mm, a length of 38 mm, and a gross weight of 3.5 g. We demonstrated the utility of this smart phone-based PNRP by measuring two well-established plasmonic nanosensors with this system. In the first experiment, the device measured the morphology changes of triangular silver nanoprisms (AgNPRs) in an immunoassay for the detection of carcinoembryonic antigen (CEA). In the second experiment, the device measured the aggregation of gold nanoparticles (AuNPs) in an aptamer-based assay for the detection of adenosine triphosphate (ATP). The results from the smart phone-based PNRP were consistent with those from commercial spectrophotometers, demonstrating that the smart phone-based PNRP enables accurate quantification of plasmonic nanosensors.
Collapse
Affiliation(s)
- Qiangqiang Fu
- Department of Bioengineering, Guangdong Province Key Laboratory of Molecular Immunology and Antibody Engineering, Jinan University, Guangzhou 510632, PR China.
| | | | | | | | | | | | | | | | | |
Collapse
|