101
|
Kieselmann JP, Kamerling CP, Burgos N, Menten MJ, Fuller CD, Nill S, Cardoso MJ, Oelfke U. Geometric and dosimetric evaluations of atlas-based segmentation methods of MR images in the head and neck region. Phys Med Biol 2018; 63:145007. [PMID: 29882749 PMCID: PMC6296440 DOI: 10.1088/1361-6560/aacb65] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 06/01/2018] [Accepted: 06/08/2018] [Indexed: 11/19/2022]
Abstract
Owing to its excellent soft-tissue contrast, magnetic resonance (MR) imaging has found an increased application in radiation therapy (RT). By harnessing these properties for treatment planning, automated segmentation methods can alleviate the manual workload burden to the clinical workflow. We investigated atlas-based segmentation methods of organs at risk (OARs) in the head and neck (H&N) region using one approach that selected the most similar atlas from a library of segmented images and two multi-atlas approaches. The latter were based on weighted majority voting and an iterative atlas-fusion approach called STEPS. We built the atlas library from pre-treatment T1-weighted MR images of 12 patients with manual contours of the parotids, spinal cord and mandible, delineated by a clinician. Following a leave-one-out cross-validation strategy, we measured the geometric accuracy by calculating Dice similarity coefficients (DSC), standard and 95% Hausdorff distances (HD and HD95), and the mean surface distance (MSD), whereby the manual contours served as the gold standard. To benchmark the algorithm, we determined the inter-observer variability (IOV) between three observers. To investigate the dosimetric effect of segmentation inaccuracies, we implemented an auto-planning strategy within the treatment planning system Monaco (Elekta AB, Stockholm, Sweden). For each set of auto-segmented OARs, we generated a plan for a 9-beam step and shoot intensity modulated RT treatment, designed according to our institution's clinical H&N protocol. Superimposing the dose distributions on the gold standard OARs, we calculated dose differences to OARs caused by delineation differences between auto-segmented and gold standard OARs. We investigated the correlations between geometric and dosimetric differences. The mean DSC was larger than 0.8 and the mean MSD smaller than 2 mm for the multi-atlas approaches, resulting in a geometric accuracy comparable to previously published results and within the range of the IOV. While dosimetric differences could be as large as 23% of the clinical goal, treatment plans fulfilled all imposed clinical goals for the gold standard OARs. Correlations between geometric and dosimetric measures were low with R2 < 0.5. The geometric accuracy and the ability to achieve clinically acceptable treatment plans indicate the suitability of using atlas-based contours for RT treatment planning purposes. The low correlations between geometric and dosimetric measures suggest that geometric measures alone are not sufficient to predict the dosimetric impact of segmentation inaccuracies on treatment planning for the data utilised in this study.
Collapse
Affiliation(s)
- J P Kieselmann
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - C P Kamerling
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - N Burgos
- University
College London, Centre for Medical Image Computing, London,
United Kingdom
- Inria, Aramis project-team, Institut du Cerveau et de la Moelle
épinière, Sorbonne Université, Paris,
France
| | - M J Menten
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - C D Fuller
- Department of Radiation Oncology,
MD Anderson Cancer Center,
Houston, TX, United States of America
| | - S Nill
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - M J Cardoso
- University
College London, Centre for Medical Image Computing, London,
United Kingdom
- School of
Biomedical Engineering and Imaging Sciences, King’s College,
London, United Kingdom
| | - U Oelfke
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| |
Collapse
|
102
|
Muller M, Paganelli C, Keall P. A phantom study to create synthetic CT from orthogonal twodimensional cine MRI and evaluate the effect of irregular breathing. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:4162-4165. [PMID: 30441272 DOI: 10.1109/embc.2018.8513236] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
An exciting innovation in radiotherapy is the use of real-time MRI for treatment adaptation. This study proposes an in-silico framework for the generation of 3D synthetic CT (sCT) from orthogonal interleaved 2D cine MRI data to overcome the lack of electron density information in MR images. The method uses pre-treatment data to build a patient breathing motion model. This model is then driven by surrogates extracted from cine MR images during the treatment. The effect of irregular breathing on the motion model is also evaluated by simulating different motion components related to uncorrelated diaphragm, chest and tumor motion. 3D sCT were successfully created for each of the 512 cine MRI pairs in the digital phantom study. The analysis showed that the diaphragm position was a good surrogate to rescale the 3D breathing motion for the current regular breathing phase. However, respiratory and tumor motion were correlated in only 59% of the phases, resulting in tumor position uncertainties of up to 3mm. The inclusion of additional chest and tumor motion information improved the accuracy for irregular changes in breathing pattern and enhanced the tumor position uncertainties to less than 1mm. This study successfully demonstrated a proof-ofprinciple for a digital phantom dataset based on patient parameters, providing a way to create real-time 3D electron density volumes and enhancing the need to account for irregular breathing pattern.
Collapse
|
103
|
Kieselmann JP, Kamerling CP, Burgos N, Menten MJ, Fuller CD, Nill S, Cardoso MJ, Oelfke U. Geometric and dosimetric evaluations of atlas-based segmentation methods of MR images in the head and neck region. Phys Med Biol 2018; 63:145007. [PMID: 29882749 PMCID: PMC6296440 DOI: 10.1088/1361-6560/aacb65;145007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Owing to its excellent soft-tissue contrast, magnetic resonance (MR) imaging has found an increased application in radiation therapy (RT). By harnessing these properties for treatment planning, automated segmentation methods can alleviate the manual workload burden to the clinical workflow. We investigated atlas-based segmentation methods of organs at risk (OARs) in the head and neck (H&N) region using one approach that selected the most similar atlas from a library of segmented images and two multi-atlas approaches. The latter were based on weighted majority voting and an iterative atlas-fusion approach called STEPS. We built the atlas library from pre-treatment T1-weighted MR images of 12 patients with manual contours of the parotids, spinal cord and mandible, delineated by a clinician. Following a leave-one-out cross-validation strategy, we measured the geometric accuracy by calculating Dice similarity coefficients (DSC), standard and 95% Hausdorff distances (HD and HD95), and the mean surface distance (MSD), whereby the manual contours served as the gold standard. To benchmark the algorithm, we determined the inter-observer variability (IOV) between three observers. To investigate the dosimetric effect of segmentation inaccuracies, we implemented an auto-planning strategy within the treatment planning system Monaco (Elekta AB, Stockholm, Sweden). For each set of auto-segmented OARs, we generated a plan for a 9-beam step and shoot intensity modulated RT treatment, designed according to our institution's clinical H&N protocol. Superimposing the dose distributions on the gold standard OARs, we calculated dose differences to OARs caused by delineation differences between auto-segmented and gold standard OARs. We investigated the correlations between geometric and dosimetric differences. The mean DSC was larger than 0.8 and the mean MSD smaller than 2 mm for the multi-atlas approaches, resulting in a geometric accuracy comparable to previously published results and within the range of the IOV. While dosimetric differences could be as large as 23% of the clinical goal, treatment plans fulfilled all imposed clinical goals for the gold standard OARs. Correlations between geometric and dosimetric measures were low with R2 < 0.5. The geometric accuracy and the ability to achieve clinically acceptable treatment plans indicate the suitability of using atlas-based contours for RT treatment planning purposes. The low correlations between geometric and dosimetric measures suggest that geometric measures alone are not sufficient to predict the dosimetric impact of segmentation inaccuracies on treatment planning for the data utilised in this study.
Collapse
Affiliation(s)
- J P Kieselmann
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom,
| | - C P Kamerling
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - N Burgos
- University
College London, Centre for Medical Image Computing, London,
United Kingdom,Inria, Aramis project-team, Institut du Cerveau et de la Moelle
épinière, Sorbonne Université, Paris,
France
| | - M J Menten
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - C D Fuller
- Department of Radiation Oncology,
MD Anderson Cancer Center,
Houston, TX, United States of America
| | - S Nill
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - M J Cardoso
- University
College London, Centre for Medical Image Computing, London,
United Kingdom,School of
Biomedical Engineering and Imaging Sciences, King’s College,
London, United Kingdom
| | - U Oelfke
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| |
Collapse
|
104
|
Schellhammer SM, Gantz S, Lühr A, Oborn BM, Bussmann M, Hoffmann AL. Technical Note: Experimental verification of magnetic field-induced beam deflection and Bragg peak displacement for MR-integrated proton therapy. Med Phys 2018; 45:3429-3434. [PMID: 29763970 DOI: 10.1002/mp.12961] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 03/26/2018] [Accepted: 04/16/2018] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Given its sensitivity to anatomical variations, proton therapy is expected to benefit greatly from integration with magnetic resonance imaging for online anatomy monitoring during irradiation. Such an integration raises several challenges, as both systems mutually interact. The proton beam will experience quasi-continuous energy loss and energy-dependent electromagnetic deflection at the same time, giving rise to a deflected beam trajectory and an altered dose distribution with a displaced Bragg peak. So far, these effects have only been predicted using Monte Carlo and analytical models, but no clear consensus has been reached and experimental benchmark data are lacking. We measured proton beam trajectories and Bragg peak displacement in a homogeneous phantom placed inside a magnetic field and compared them to simulations. METHODS Planar dose distributions of proton pencil beams (80-180 MeV) traversing the field of a 0.95 T NdFeB permanent magnet while depositing energy in a PMMA slab phantom were measured using EBT3 radiochromic films and simulated using the Geant4 toolkit. Deflected beam trajectories and the Bragg peak displacement were extracted from the measured planar dose distributions and compared against the simulations. RESULTS The lateral beam deflection was clearly visible on the EBT3 films and ranged from 1 to 10 mm for 80 to 180 MeV, respectively. Simulated and measured beam trajectories and Bragg peak displacement agreed within 0.8 mm for all studied proton energies. CONCLUSIONS These results prove that the magnetic field-induced Bragg peak displacement is both measurable and accurately predictable in a homogeneous phantom at 0.95 T, and allows Monte Carlo simulations to be used as gold standard for proton beam trajectory prediction in similar frameworks for MR-integrated proton therapy.
Collapse
Affiliation(s)
- Sonja M Schellhammer
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01307, Germany.,Institute of Radiooncology - OncoRay, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01328, Germany
| | - Sebastian Gantz
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01307, Germany.,Institute of Radiooncology - OncoRay, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01328, Germany
| | - Armin Lühr
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01307, Germany.,Institute of Radiooncology - OncoRay, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01328, Germany.,German Cancer Consortium (DKTK), Partner Site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, 69120, Germany
| | - Bradley M Oborn
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, 2522, Australia.,Illawarra Cancer Care Centre, Wollongong Hospital, Wollongong, 2522, Australia
| | - Michael Bussmann
- Institute of Radiation Physics, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01328, Germany
| | - Aswin L Hoffmann
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01307, Germany.,Institute of Radiooncology - OncoRay, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01328, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, 01307, Germany
| |
Collapse
|
105
|
Hua CH, Uh J, Krasin MJ, Lucas JT, Tinkle CL, Acharya S, Smith HL, Kadbi M, Merchant TE. Clinical Implementation of Magnetic Resonance Imaging Systems for Simulation and Planning of Pediatric Radiation Therapy. J Med Imaging Radiat Sci 2018; 49:153-163. [DOI: 10.1016/j.jmir.2018.02.054] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 01/31/2018] [Accepted: 02/20/2018] [Indexed: 01/10/2023]
|
106
|
Emmerich J, Laun FB, Pfaffenberger A, Schilling R, Denoix M, Maier F, Sterzing F, Bostel T, Straub S. Technical Note: On the size of susceptibility-induced MR image distortions in prostate and cervix in the context of MR-guided radiation therapy. Med Phys 2018; 45:1586-1593. [DOI: 10.1002/mp.12785] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Revised: 12/11/2017] [Accepted: 01/14/2018] [Indexed: 11/06/2022] Open
Affiliation(s)
- Julian Emmerich
- Department of Medical Physics in Radiology; German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Frederik B. Laun
- Department of Medical Physics in Radiology; German Cancer Research Center (DKFZ); Heidelberg Germany
- Institute of Radiology; University Hospital Erlangen; Erlangen Germany
| | - Asja Pfaffenberger
- Department of Medical Physics in Radiation Oncology; German Cancer Research Center (DKFZ); Heidelberg Germany
| | | | - Michael Denoix
- Department of Medical Physics in Radiology; German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Florian Maier
- Department of Medical Physics in Radiology; German Cancer Research Center (DKFZ); Heidelberg Germany
| | - Florian Sterzing
- Clinical Cooperation Unit Radiation Oncology; German Cancer Research Center (DKFZ); Heidelberg Germany
- Department of Radiation Oncology; University Hospital Heidelberg; Heidelberg Germany
- National Center for Research in Radiation Oncology; Heidelberg Institute for Radiation Oncology (HIRO); Heidelberg Germany
| | - Tilman Bostel
- Clinical Cooperation Unit Radiation Oncology; German Cancer Research Center (DKFZ); Heidelberg Germany
- Department of Radiation Oncology; University Hospital Heidelberg; Heidelberg Germany
- National Center for Research in Radiation Oncology; Heidelberg Institute for Radiation Oncology (HIRO); Heidelberg Germany
| | - Sina Straub
- Department of Medical Physics in Radiology; German Cancer Research Center (DKFZ); Heidelberg Germany
| |
Collapse
|
107
|
Paganelli C, Lee D, Kipritidis J, Whelan B, Greer PB, Baroni G, Riboldi M, Keall P. Feasibility study on 3D image reconstruction from 2D orthogonal cine-MRI for MRI-guided radiotherapy. J Med Imaging Radiat Oncol 2018; 62:389-400. [DOI: 10.1111/1754-9485.12713] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Accepted: 01/12/2018] [Indexed: 12/25/2022]
Affiliation(s)
- Chiara Paganelli
- Dipartimento di Elettronica, Informazione e Bioingegneria; Politecnico di Milano; Milano Italy
| | - Danny Lee
- Department of Radiation Oncology; Calvary Mater Newcastle; Newcastle New South Wales Australia
| | - John Kipritidis
- Northern Sydney Cancer Centre; Royal North Shore Hospital; Sydney New South Wales Australia
- ACRF Image X Institute; Sydney Medical School; University of Sydney; Sydney New South Wales Australia
| | - Brendan Whelan
- ACRF Image X Institute; Sydney Medical School; University of Sydney; Sydney New South Wales Australia
| | - Peter B Greer
- Department of Radiation Oncology; Calvary Mater Newcastle; Newcastle New South Wales Australia
- School of Mathematical and Physical Sciences; University of Newcastle; Newcastle New South Wales Australia
| | - Guido Baroni
- Dipartimento di Elettronica, Informazione e Bioingegneria; Politecnico di Milano; Milano Italy
- Bioengineering Unit; Centro Nazionale di Adroterapia Oncologica; Pavia Italy
| | - Marco Riboldi
- Department of Medical Physics; Ludwig-Maximilians-Universität München; Munich Germany
| | - Paul Keall
- ACRF Image X Institute; Sydney Medical School; University of Sydney; Sydney New South Wales Australia
| |
Collapse
|
108
|
Dose enhancement effects of gold nanoparticles specifically targeting RNA in breast cancer cells. PLoS One 2018; 13:e0190183. [PMID: 29346397 PMCID: PMC5773234 DOI: 10.1371/journal.pone.0190183] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Accepted: 12/08/2017] [Indexed: 01/02/2023] Open
Abstract
Localization microscopy has shown to be capable of systematic investigations on the arrangement and counting of cellular uptake of gold nanoparticles (GNP) with nanometer resolution. In this article, we show that the application of specially modified RNA targeting gold nanoparticles ("SmartFlares") can result in ring like shaped GNP arrangements around the cell nucleus. Transmission electron microscopy revealed GNP accumulation in vicinity to the intracellular membrane structures including them of the endoplasmatic reticulum. A quantification of the radio therapeutic dose enhancement as a proof of principle was conducted with γH2AX foci analysis: The application of both-SmartFlares and unmodified GNPs-lead to a significant dose enhancement with a factor of up to 1.2 times the dose deposition compared to non-treated breast cancer cells. This enhancement effect was even more pronounced for SmartFlares. Furthermore, it was shown that a magnetic field of 1 Tesla simultaneously applied during irradiation has no detectable influence on neither the structure nor the dose enhancement dealt by gold nanoparticles.
Collapse
|
109
|
O'Brien DJ, Dolan J, Pencea S, Schupp N, Sawakuchi GO. Relative dosimetry with an MR-linac: Response of ion chambers, diamond, and diode detectors for off-axis, depth dose, and output factor measurements. Med Phys 2017; 45:884-897. [PMID: 29178457 DOI: 10.1002/mp.12699] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 11/16/2017] [Accepted: 11/21/2017] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The purpose of this study was to acquire beam data for an MR-linac, with and without a 1.5 T magnetic field, by using a variety of commercially available detectors to assess their relative response in the magnetic field. The impact of the magnetic field on the measured dose distribution was also assessed. METHODS An MR-safe 3D scanning water phantom was used to measure output factors, depth dose curves, and off-axis profiles for various depths and for field sizes between 2 × 2 cm2 and 22 × 22 cm2 for an Elekta MR-linac beam with the orthogonal 1.5 T magnetic field on or off. An on-board MV portal imaging system was used to ensure that the reproducibility of the detector position, both with and without the magnetic field, was within 0.1 mm. The detectors used included ionization chambers with large, medium, and small sensitive volumes; a diamond detector; a shielded diode; and an unshielded diode. RESULTS The offset of the effective point of measurement of the ionization chambers was found to be reduced by at least half for each chamber in the direction parallel with the beam. A lateral shift of similar magnitude was also introduced to the chambers' effective point of measurement toward the average direction of the Lorentz force. A similar lateral shift (but in the opposite direction) was also observed for the diamond and diode detectors. The measured lateral shift in the dose distribution was independent of depth and field size for each detector for fields between 2 × 2 cm2 and 10 × 10 cm2 . The shielded diode significantly misrepresented the dose distribution in the lateral direction perpendicular to the magnetic field, making it seem more symmetric. The percentage depth dose was generally found to be lower with the magnetic field than without, but this difference was reduced as field size increased. The depth of maximum dose showed little dependence on field size in the presence of the magnetic field, with values from 1.2 cm to 1.3 cm between the 2 × 2 cm2 and 22 × 22 cm2 fields. Output factors measured in the magnetic field at the center of the beam profile produced a larger spread of values between detectors for fields smaller than 10 × 10 cm2 (with a spread of 2% at 3 × 3 cm2 ). The spread of values was more consistent when the output factors were measured at the point of peak intensity of the lateral dose distribution instead (except for the shielded diode which differed by up to 2% depending on field size). CONCLUSIONS The magnetic field of the MR-linac alters the effective point of measurement of ionization chambers, shifting it both downstream and laterally. Shielded diodes produce incorrect and misleading dose profiles. The output factor measured at the point of peak intensity in the lateral dose distribution is more robust than the conventional output factor (measured at central axis). Diodes are not recommended for output factor measurements in the magnetic field.
Collapse
Affiliation(s)
- Daniel J O'Brien
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - James Dolan
- Elekta Software, Elekta A. B., Maryland Heights, MO, 63043, USA
| | - Stefan Pencea
- Elekta Software, Elekta A. B., Maryland Heights, MO, 63043, USA
| | - Nicholas Schupp
- Elekta Software, Elekta A. B., Maryland Heights, MO, 63043, USA
| | - Gabriel O Sawakuchi
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA.,Graduate School of Biomedical Sciences, The University of Texas, Houston, TX, 77030, USA
| |
Collapse
|
110
|
Raaymakers BW, Jürgenliemk-Schulz IM, Bol GH, Glitzner M, Kotte ANTJ, van Asselen B, de Boer JCJ, Bluemink JJ, Hackett SL, Moerland MA, Woodings SJ, Wolthaus JWH, van Zijp HM, Philippens MEP, Tijssen R, Kok JGM, de Groot-van Breugel EN, Kiekebosch I, Meijers LTC, Nomden CN, Sikkes GG, Doornaert PAH, Eppinga WSC, Kasperts N, Kerkmeijer LGW, Tersteeg JHA, Brown KJ, Pais B, Woodhead P, Lagendijk JJW. First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment. ACTA ACUST UNITED AC 2017; 62:L41-L50. [PMID: 29135471 DOI: 10.1088/1361-6560/aa9517] [Citation(s) in RCA: 355] [Impact Index Per Article: 50.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
111
|
Harrington K, Hall E, Hawkins M, Henry A, MacKay R, Maughan T, McDonald A, Nutting C, Oelfke U, Sebag-Montefiore D, Sharma RA, van Herk M, Faivre-Finn C. Introducing the Cancer Research UK Advanced Radiotherapy Technologies Network (ART-NET). Clin Oncol (R Coll Radiol) 2017; 29:707-710. [PMID: 28807360 PMCID: PMC6155492 DOI: 10.1016/j.clon.2017.07.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 06/30/2017] [Accepted: 07/08/2017] [Indexed: 12/25/2022]
Affiliation(s)
| | - E Hall
- Institute of Cancer Research, London, UK
| | - M Hawkins
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Oxford, UK
| | - A Henry
- Leeds Teaching Hospitals NHS Trust, Leeds, UK; University of Leeds, Leeds, UK
| | - R MacKay
- University of Manchester, Manchester, UK; The Christie NHS Foundation Trust, Manchester, UK
| | | | - A McDonald
- Institute of Cancer Research, London, UK
| | - C Nutting
- The Royal Marsden NHS Foundation Trust, London, UK
| | - U Oelfke
- Institute of Cancer Research, London, UK
| | - D Sebag-Montefiore
- Leeds Teaching Hospitals NHS Trust, Leeds, UK; University of Leeds, Leeds, UK
| | - R A Sharma
- University College London, London, UK; NIHR University College London Hospitals Biomedical Research Centre, London, UK
| | - M van Herk
- University of Manchester, Manchester, UK
| | - C Faivre-Finn
- University of Manchester, Manchester, UK; The Christie NHS Foundation Trust, Manchester, UK.
| |
Collapse
|
112
|
Chuter RW, Whitehurst P, Choudhury A, van Herk M, McWilliam A. Technical Note: Investigating the impact of field size on patient selection for the 1.5T MR-Linac. Med Phys 2017; 44:5667-5671. [PMID: 28869651 DOI: 10.1002/mp.12557] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 08/10/2017] [Accepted: 08/14/2017] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The 1.5 T Elekta MR-Linac, due to the construction of the system will have a maximum radiation field size in the superior-inferior patient direction of 22 cm at isocentre. The field size may impact on the patient groups which can be treated on the system. This technical note aims to address the question of which treatment sites will be affected by field size limitations on the MR-Linac. METHODS Using historical data for 11 595 cases over 2 yr treated at the authors' institution, the proportion of plans that would fit the MR-Linac's field size was determined for eleven patient groups. In addition, cervix plans were analyzed to determine the length of the two Clinical Target Volumes (CTVs) and any overlap between them. RESULTS With a 1 cm margin to allow for online plan adaption, 80% of all plans would be suitable for the MR-Linac due to the field size. This percentage increases to 100% for smaller tumor volumes such as prostate and brain. However, for cervix and three dose-level head and neck plans the percentage becomes 61% and 66%, respectively. CONCLUSION The maximum radiation field size of the MR-Linac in the superior-inferior patient direction is 22 cm. With a 1 cm margin approximately 80% of all plans would be suitable for the MR-Linac with the available field size, decreasing to 61% for larger tumor volumes. For cervix patients this may motivate investigations into treating each CTV with a separate isocentre, allowing for careful control of matching fields.
Collapse
Affiliation(s)
- Robert W Chuter
- Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Wilmslow Road, Manchester, M20 4BX, UK
- Division of Cancer Sciences, Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Sciences Centre, Manchester, M13 9PL, UK
| | - Philip Whitehurst
- Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Wilmslow Road, Manchester, M20 4BX, UK
| | - Ananya Choudhury
- Division of Cancer Sciences, Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Sciences Centre, Manchester, M13 9PL, UK
- Clinical Oncology, The Christie NHS Foundation Trust, Wilmslow Road, Manchester, M20 4BX, UK
| | - Marcel van Herk
- Division of Cancer Sciences, Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Sciences Centre, Manchester, M13 9PL, UK
| | - Alan McWilliam
- Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Wilmslow Road, Manchester, M20 4BX, UK
- Division of Cancer Sciences, Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Sciences Centre, Manchester, M13 9PL, UK
| |
Collapse
|
113
|
Ghose S, Greer PB, Sun J, Pichler P, Rivest-Henault D, Mitra J, Richardson H, Wratten C, Martin J, Arm J, Best L, Dowling JA. Regression and statistical shape model based substitute CT generation for MRI alone external beam radiation therapy from standard clinical MRI sequences. Phys Med Biol 2017; 62:8566-8580. [PMID: 28976369 DOI: 10.1088/1361-6560/aa9104] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
In MR only radiation therapy planning, generation of the tissue specific HU map directly from the MRI would eliminate the need of CT image acquisition and may improve radiation therapy planning. The aim of this work is to generate and validate substitute CT (sCT) scans generated from standard T2 weighted MR pelvic scans in prostate radiation therapy dose planning. A Siemens Skyra 3T MRI scanner with laser bridge, flat couch and pelvic coil mounts was used to scan 39 patients scheduled for external beam radiation therapy for localized prostate cancer. For sCT generation a whole pelvis MRI (1.6 mm 3D isotropic T2w SPACE sequence) was acquired. Patients received a routine planning CT scan. Co-registered whole pelvis CT and T2w MRI pairs were used as training images. Advanced tissue specific non-linear regression models to predict HU for the fat, muscle, bladder and air were created from co-registered CT-MRI image pairs. On a test case T2w MRI, the bones and bladder were automatically segmented using a novel statistical shape and appearance model, while other soft tissues were separated using an Expectation-Maximization based clustering model. The CT bone in the training database that was most 'similar' to the segmented bone was then transformed with deformable registration to create the sCT component of the test case T2w MRI bone tissue. Predictions for the bone, air and soft tissue from the separate regression models were successively combined to generate a whole pelvis sCT. The change in monitor units between the sCT-based plans relative to the gold standard CT plan for the same IMRT dose plan was found to be [Formula: see text] (mean ± standard deviation) for 39 patients. The 3D Gamma pass rate was [Formula: see text] (2 mm/2%). The novel hybrid model is computationally efficient, generating an sCT in 20 min from standard T2w images for prostate cancer radiation therapy dose planning and DRR generation.
Collapse
Affiliation(s)
- Soumya Ghose
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States of America
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
114
|
Perik T, Kaas J, Wittkämper F. The impact of a 1.5 T MRI linac fringe field on neighbouring linear accelerators. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2017. [DOI: 10.1016/j.phro.2017.10.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
115
|
Freedman JN, Collins DJ, Bainbridge H, Rank CM, Nill S, Kachelrieß M, Oelfke U, Leach MO, Wetscherek A. T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning. Invest Radiol 2017; 52:563-573. [PMID: 28459800 PMCID: PMC5581953 DOI: 10.1097/rli.0000000000000381] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Accepted: 03/20/2017] [Indexed: 12/13/2022]
Abstract
OBJECTIVES The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. MATERIALS AND METHODS Ten patients with primary non-small cell lung cancer were scanned at 1.5 T axially with a volumetric T2-weighted turbo spin echo sequence gated to exhalation and a volumetric T1-weighted stack-of-stars spoiled gradient echo sequence with golden angle spacing acquired in free breathing. From the latter, 20 respiratory phases were reconstructed using the recently developed 4D joint MoCo-HDTV algorithm based on the self-gating signal obtained from the k-space center. Motion vector fields describing the respiratory cycle were obtained by deformable image registration between the respiratory phases and projected onto the T2-weighted image volume. The resulting 4D-T2w volumes were verified against the 4D-T1w volumes: an edge-detection method was used to measure the diaphragm positions; the locations of anatomical landmarks delineated by a radiation oncologist were compared and normalized mutual information was calculated to evaluate volumetric image similarity. RESULTS High-resolution 4D-T2w MRI was obtained. Respiratory motion was preserved on calculated 4D-T2w MRI, with median diaphragm positions being consistent with less than 6.6 mm (2 voxels) for all patients and less than 3.3 mm (1 voxel) for 9 of 10 patients. Geometrical positions were coherent between 4D-T1w and 4D-T2w MRI as Euclidean distances between all corresponding anatomical landmarks agreed to within 7.6 mm (Euclidean distance of 2 voxels) and were below 3.8 mm (Euclidean distance of 1 voxel) for 355 of 470 pairs of anatomical landmarks. Volumetric image similarity was commensurate between 4D-T1w and 4D-T2w MRI, as mean percentage differences in normalized mutual information (calculated over all respiratory phases and patients), between corresponding respiratory phases of 4D-T1w and 4D-T2w MRI and the tie-phase of 4D-T1w and 3-dimensional T2w MRI, were consistent to 0.41% ± 0.37%. Four-dimensional T2w MRI displayed tumor extent, structure, and position more clearly than corresponding 4D-T1w MRI, especially when mobile tumor sites were adjacent to organs at risk. CONCLUSIONS A methodology to obtain 4D-T2w MRI that retrospectively applies the motion information from 4D-T1w MRI to 3-dimensional T2w MRI was developed and verified. Four-dimensional T2w MRI can assist clinicians in delineating mobile lesions that are difficult to define on 4D-T1w MRI, because of poor tumor-tissue contrast.
Collapse
Affiliation(s)
- Joshua N. Freedman
- From the *Joint Department of Physics, †CR UK Cancer Imaging Centre, and ‡Joint Department of Radiotherapy, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; and §Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - David J. Collins
- From the *Joint Department of Physics, †CR UK Cancer Imaging Centre, and ‡Joint Department of Radiotherapy, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; and §Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Hannah Bainbridge
- From the *Joint Department of Physics, †CR UK Cancer Imaging Centre, and ‡Joint Department of Radiotherapy, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; and §Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Christopher M. Rank
- From the *Joint Department of Physics, †CR UK Cancer Imaging Centre, and ‡Joint Department of Radiotherapy, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; and §Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Simeon Nill
- From the *Joint Department of Physics, †CR UK Cancer Imaging Centre, and ‡Joint Department of Radiotherapy, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; and §Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Marc Kachelrieß
- From the *Joint Department of Physics, †CR UK Cancer Imaging Centre, and ‡Joint Department of Radiotherapy, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; and §Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Uwe Oelfke
- From the *Joint Department of Physics, †CR UK Cancer Imaging Centre, and ‡Joint Department of Radiotherapy, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; and §Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Martin O. Leach
- From the *Joint Department of Physics, †CR UK Cancer Imaging Centre, and ‡Joint Department of Radiotherapy, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; and §Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Andreas Wetscherek
- From the *Joint Department of Physics, †CR UK Cancer Imaging Centre, and ‡Joint Department of Radiotherapy, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; and §Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
116
|
Kim A, Lim-Reinders S, McCann C, Ahmad SB, Sahgal A, Lee J, Keller BM. Magnetic field dose effects on different radiation beam geometries for hypofractionated partial breast irradiation. J Appl Clin Med Phys 2017; 18:62-70. [PMID: 28901729 PMCID: PMC5689934 DOI: 10.1002/acm2.12182] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Revised: 08/04/2017] [Accepted: 08/07/2017] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Hypofractionated partial breast irradiation (HPBI) involves treatment to the breast tumor using high doses per fraction. Recent advances in MRI-Linac solutions have potential in being applied to HPBI due to gains in the soft tissue contrast of MRI; however, there are potentially deleterious effects of the magnetic field on the dose distribution. The purpose of this work is to determine the effects of the magnetic field on the dose distribution for HPBI tumors using a tangential beam arrangement (TAN), 5-beam intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). METHODS Five patients who have received HPBI were selected with two patients having bilateral disease resulting in a total of two tumors in this study. Six planning configurations were created using a treatment planning system capable of modeling magnetic field dose effects: TAN, IMRT and VMAT beam geometries, each of these optimized with and without a transverse magnetic field of 1.5 T. RESULTS The heart and lung doses were not statistically significant when comparing plan configurations. The magnetic field had a demonstrated effect on skin dose: for VMAT plans, the skin (defined to a depth of 3 mm) D1cc was elevated by +11% and the V30 by +146%; for IMRT plans, the skin D1cc was increased by +18% and the V30 by +149%. Increasing the number of beam angles (e.g., going from IMRT to VMAT) with the magnetic field on reduced the skin dose. CONCLUSION The impact of a magnetic field on HPBI dose distributions was analyzed. The heart and lung doses had clinically negligible effects caused by the magnetic field. The magnetic field increases the skin dose; however, this can be mitigated by increasing the number of beam angles.
Collapse
Affiliation(s)
- Anthony Kim
- Department of Medical Physics, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, ON, Canada.,Faculty of Medicine, Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Stephanie Lim-Reinders
- Department of Medical Physics, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, ON, Canada
| | - Claire McCann
- Department of Medical Physics, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, ON, Canada.,Faculty of Medicine, Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Syed Bilal Ahmad
- Department of Medical Physics, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, ON, Canada
| | - Arjun Sahgal
- Faculty of Medicine, Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada.,Department of Radiation Oncology, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, ON, Canada
| | - Justin Lee
- Faculty of Medicine, Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada.,Department of Radiation Oncology, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, ON, Canada
| | - Brian M Keller
- Department of Medical Physics, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, ON, Canada.,Faculty of Medicine, Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
117
|
Soliman AS, Burns L, Owrangi A, Lee Y, Song WY, Stanisz G, Chugh BP. A realistic phantom for validating MRI-based synthetic CT images of the human skull. Med Phys 2017. [PMID: 28644905 DOI: 10.1002/mp.12428] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To introduce a new realistic human skull phantom for the validation of synthetic CT images of cortical bone from ultra-short echo-time (UTE) sequences. METHODS A human skull of an adult female was utilized as a realistic representation of skull cortical bone. The skull was stabilized in a special acrylic container and was filled with contrast agents that have T1 and T2 relaxation times similar to human brain. The phantom was MR scanned at 3T with UTE and T2 -weighted sequences, followed by CT. A clustering approach was developed to extract the cortical bone signal from MR images. T2∗ maps of the skull were calculated. Synthetic CT images of the bone were compared to cortical bone signal extracted from CT images and confounding factors, such as registration errors, were analyzed. RESULTS Dice similarity coefficient (DSC) of UTE-detected cortical bone was 0.84 and gradually decreased with decreasing number of spokes. DSC did not significantly depend on echo-time. Registration errors were found to be significant confounding factors, with 25% decrease in DSC for consistent 2 mm error at each axis. CONCLUSION This work introduced a new realistic human skull phantom, specifically for the evaluation and analysis of synthetic CT images of cortical bone.
Collapse
Affiliation(s)
- Abraam S Soliman
- Medical Physics, Sunnybrook Health Sciences Centre, Toronto, ON, M4N 3M5, Canada.,Physical Sciences, Sunnybrook Research Institute, Toronto, ON, M4N 3M5, Canada
| | - Levi Burns
- Medical Physics, Sunnybrook Health Sciences Centre, Toronto, ON, M4N 3M5, Canada.,Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1, Canada
| | - Amir Owrangi
- Medical Physics, Sunnybrook Health Sciences Centre, Toronto, ON, M4N 3M5, Canada.,Radiation Oncology, University of Toronto, Toronto, ON, M5S 3E2, Canada
| | - Young Lee
- Medical Physics, Sunnybrook Health Sciences Centre, Toronto, ON, M4N 3M5, Canada.,Radiation Oncology, University of Toronto, Toronto, ON, M5S 3E2, Canada
| | - William Y Song
- Medical Physics, Sunnybrook Health Sciences Centre, Toronto, ON, M4N 3M5, Canada.,Physical Sciences, Sunnybrook Research Institute, Toronto, ON, M4N 3M5, Canada.,Radiation Oncology, University of Toronto, Toronto, ON, M5S 3E2, Canada
| | - Greg Stanisz
- Medical Physics, Sunnybrook Health Sciences Centre, Toronto, ON, M4N 3M5, Canada.,Physical Sciences, Sunnybrook Research Institute, Toronto, ON, M4N 3M5, Canada.,Medical Biophysics, University of Toronto, Toronto, ON, M4N 3M5, Canada
| | - Brige P Chugh
- Medical Physics, Sunnybrook Health Sciences Centre, Toronto, ON, M4N 3M5, Canada.,Radiation Oncology, University of Toronto, Toronto, ON, M5S 3E2, Canada
| |
Collapse
|
118
|
Andreychenko A, Denis de Senneville B, Navest RJM, Tijssen RHN, Lagendijk JJW, van den Berg CAT. Respiratory motion model based on the noise covariance matrix of a receive array. Magn Reson Med 2017; 79:1730-1735. [PMID: 28593709 DOI: 10.1002/mrm.26775] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Revised: 04/20/2017] [Accepted: 05/15/2017] [Indexed: 11/12/2022]
Abstract
PURPOSE Tracking of the internal anatomy by means of a motion model that uses the MR-derived motion fields and noise covariance matrix (NCM) dynamic as a surrogate signal. METHODS A 2D respiratory motion model was developed based on the MR-derived motion fields and the NCM of a receive array used in MRI. Temporal dynamics of the NCM were used as a motion surrogate for a linear correspondence motion model. The model performance was tested on five healthy volunteers with a liver as the target. The motion fields were calculated from the cineMR frames with an optical flow registration tool. RESULTS The model estimated the liver motion with an average residual error of 2.3 mm (13% of the motion amplitude). The model formation takes 3 min and the model latency was 0.5 s in the current implementation. The limiting factor for the latency is the current update time of the NCM (0.48 s), which in principle can be reduced to 0.004 s with an alternative way to determine the NCM. CONCLUSIONS The 2D respiratory motion of the liver can be effectively estimated with the linear motion model that uses the temporal behavior of the NCM as motion surrogate. Magn Reson Med 79:1730-1735, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- A Andreychenko
- Center for Image Sciences, University Medical Center Utrecht, the Netherlands
| | - B Denis de Senneville
- Center for Image Sciences, University Medical Center Utrecht, the Netherlands.,IMB, UMR 5251 CNRS/University of Bordeaux, Bordeaux, France
| | - R J M Navest
- Center for Image Sciences, University Medical Center Utrecht, the Netherlands
| | - R H N Tijssen
- Center for Image Sciences, University Medical Center Utrecht, the Netherlands
| | - J J W Lagendijk
- Center for Image Sciences, University Medical Center Utrecht, the Netherlands
| | - C A T van den Berg
- Center for Image Sciences, University Medical Center Utrecht, the Netherlands
| |
Collapse
|
119
|
Wang Y, Mazur TR, Park JC, Yang D, Mutic S, Li HH. Development of a fast Monte Carlo dose calculation system for online adaptive radiation therapy quality assurance. Phys Med Biol 2017; 62:4970-4990. [DOI: 10.1088/1361-6560/aa6e38] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
120
|
Huijskens SC, van Dijk IW, Visser J, Rasch CR, Alderliesten T, Bel A. Magnitude and variability of respiratory-induced diaphragm motion in children during image-guided radiotherapy. Radiother Oncol 2017; 123:263-269. [DOI: 10.1016/j.radonc.2017.03.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2016] [Revised: 02/15/2017] [Accepted: 03/13/2017] [Indexed: 12/25/2022]
|
121
|
Automated Prostate Gland Segmentation Based on an Unsupervised Fuzzy C-Means Clustering Technique Using Multispectral T1w and T2w MR Imaging. INFORMATION 2017. [DOI: 10.3390/info8020049] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
|
122
|
Pollard JM, Wen Z, Sadagopan R, Wang J, Ibbott GS. The future of image-guided radiotherapy will be MR guided. Br J Radiol 2017; 90:20160667. [PMID: 28256898 DOI: 10.1259/bjr.20160667] [Citation(s) in RCA: 135] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Advances in image-guided radiotherapy (RT) have allowed for dose escalation and more precise radiation treatment delivery. Each decade brings new imaging technologies to help improve RT patient setup. Currently, the most frequently used method of three-dimensional pre-treatment image verification is performed with cone beam CT. However, more recent developments have provided RT with the ability to have on-board MRI coupled to the teleradiotherapy unit. This latest tool for treating cancer is known as MR-guided RT. Several varieties of these units have been designed and installed in centres across the globe. Their prevalence, history, advantages and disadvantages are discussed in this review article. In preparation for the next generation of image-guided RT, this review also covers where MR-guided RT might be heading in the near future.
Collapse
Affiliation(s)
| | - Zhifei Wen
- UT MD Anderson Cancer Center, Houston, TX, USA
| | | | - Jihong Wang
- UT MD Anderson Cancer Center, Houston, TX, USA
| | | |
Collapse
|
123
|
Ghose S, Dowling JA, Rai R, Liney GP. Substitute CT generation from a single ultra short time echo MRI sequence: preliminary study. Phys Med Biol 2017; 62:2950-2960. [PMID: 28306546 DOI: 10.1088/1361-6560/aa508a] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
In MR guided radiation therapy planning both MR and CT images for a patient are acquired and co-registered to obtain a tissue specific HU map. Generation of the HU map directly from the MRI would eliminate the CT acquisition and may improve radiation therapy planning. In this preliminary study of substitute CT (sCT) generation, two porcine leg phantoms were scanned using a 3D ultrashort echo time (PETRA) sequence and co-registered to corresponding CT images to build tissue specific regression models. The model was created from one co-registered CT-PETRA pair to generate the sCT for the other PETRA image. An expectation maximization based clustering was performed on the co-registered PETRA image to identify the soft tissues, dense bone and air class membership probabilities. A tissue specific non linear regression model was built from one registered CT-PETRA pair dataset to predict the sCT of the second PETRA image in a two-fold cross validation schema. A complete substitute CT is generated in 3 min. The mean absolute HU error for air was 0.3 HU, bone was 95 HU, fat was 30 HU and for muscle it was 10 HU. The mean surface reconstruction error for the bone was 1.3 mm. The PETRA sequence enabled a low mean absolute surface distance for the bone and a low HU error for other classes. The sCT generated from a single PETRA sequence shows promise for the generation of fast sCT for MRI based radiation therapy planning.
Collapse
Affiliation(s)
- Soumya Ghose
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States of America
| | | | | | | |
Collapse
|
124
|
Demol B, Boydev C, Korhonen J, Reynaert N. Dosimetric characterization of MRI-only treatment planning for brain tumors in atlas-based pseudo-CT images generated from standard T1-weighted MR images. Med Phys 2017; 43:6557. [PMID: 27908187 DOI: 10.1118/1.4967480] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
PURPOSE Magnetic resonance imaging (MRI)-only radiotherapy treatment planning requires accurate pseudo-CT (pCT) images for precise dose calculation. The current work introduced an atlas-based method combined with MR intensity information. pCT analyses and Monte Carlo dose calculations for intracranial stereotactic treatments were performed. METHODS Twenty-two patients, representing 35 tumor targets, were scanned using a 3D T1-weighted MRI sequence according to the clinical protocol. The MR atlas image was registered to the MR patient image using a deformable algorithm, and the deformation was then applied to the atlas CT. Two methods were applied. The first method (MRdef) was based on deformations only, while the second (MRint) also used the actual MR intensities. pCT analysis was performed using the mean (absolute) error, as well as an in-house tool based on a gamma index. Dose differences between pCT and true CT were analyzed using dose-volume histogram (DVH) parameters, statistical tests, the gamma index, and probability density functions. An unusual case, where the patient underwent an operation (part of the skull bone was removed), was studied in detail. RESULTS Soft tissues presented a mean error inferior to 50 HUs, while low-density tissues and bones presented discrepancies up to 600 HUs for hard bone. The MRdef method led to significant dose differences compared with the true CT (p-value < 0.05; Wilcoxon-signed-rank test). The MRint method performed better. The DVH parameter differences compared with CT were between -2.9% and 3.1%, except for two cases where the tumors were located within the sphenoid bone. For these cases, the dose errors were up to 6.6% and 5.4% (D98 and D95). Furthermore, for 85% of the tested patients, the mean dose to the planning target volume agreed within 2% with the calculation using the actual CT. Fictitious bone was generated in the unusual case using atlas-based methods. CONCLUSIONS Generally, the atlas-based method led to acceptable dose distributions. The use of common T1 sequences allows the implementation of this method in clinical routine. However, unusual patient anatomy may produce large dose calculation errors. The detection of large anatomic discrepancies using MR image subtraction can be realized, but an alternative way to produce synthetic CT numbers in these regions is still required.
Collapse
Affiliation(s)
- Benjamin Demol
- Department of Radiotherapy, Centre Oscar Lambret, Lille 59000, France; Department of Research and Development, AQUILAB SAS, Loos Les Lille 59120, France; and Department of Research, IEMN, UMR CNRS 8520, Villeneuve d'Ascq 59650, France
| | - Christine Boydev
- Department of Radiotherapy, Centre Oscar Lambret, Lille 59000, France
| | - Juha Korhonen
- Department of Radiation Oncology, Comprehensive Cancer Center, Helsinki University Central Hospital, Helsinki FI-00029, Finland and Department of Radiology, Helsinki University Central Hospital, Helsinki FI-00029, Finland
| | - Nick Reynaert
- Department of Radiotherapy, Centre Oscar Lambret, Lille 59000, France
| |
Collapse
|
125
|
Koivula L, Wee L, Korhonen J. Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images. Med Phys 2017; 43:4634. [PMID: 27487880 DOI: 10.1118/1.4958677] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
PURPOSE Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI reference images is feasible. This study aims to show that a MRI-only based RTP workflow is also feasible for proton beam therapy plans generated in MRI-based substitute computed tomography (sCT) images of the head and the pelvis. METHODS The sCTs were constructed for ten prostate cancer and ten brain tumor patients primarily by transforming the intensity values of in-phase MR images to Hounsfield units (HUs) with a dual model HU conversion technique to enable heterogeneous tissue representation. HU conversion models for the pelvis were adopted from previous studies, further extended in this study also for head MRI by generating anatomical site-specific conversion models (a new training data set of ten other brain patients). This study also evaluated two other types of simplified sCT: dual bulk density (for bone and water) and homogeneous (water only). For every clinical case, intensity modulated proton therapy (IMPT) plans robustly optimized in standard planning CTs were calculated in sCT for evaluation, and vice versa. Overall dose agreement was evaluated using dose-volume histogram parameters and 3D gamma criteria. RESULTS In heterogeneous sCTs, the mean absolute errors in HUs were 34 (soft tissues: 13, bones: 92) and 42 (soft tissues: 9, bones: 97) in the head and in the pelvis, respectively. The maximum absolute dose differences relative to CT in the brain tumor clinical target volume (CTV) were 1.4% for heterogeneous sCT, 1.8% for dual bulk sCT, and 8.9% for homogenous sCT. The corresponding maximum differences in the prostate CTV were 0.6%, 1.2%, and 3.6%, respectively. The percentages of dose points in the head and pelvis passing 1% and 1 mm gamma index criteria were over 91%, 85%, and 38% with heterogeneous, dual bulk, and homogeneous sCTs, respectively. There were no significant changes to gamma index pass rates for IMPT plans first optimized in CT and then calculated in heterogeneous sCT versus IMPT plans first optimized in heterogeneous sCT and then calculated on standard CT. CONCLUSIONS This study demonstrates that proton therapy dose calculations on heterogeneous sCTs are in good agreement with plans generated with standard planning CT. An MRI-only based RTP workflow is feasible in IMPT for brain tumors and prostate cancers.
Collapse
Affiliation(s)
- Lauri Koivula
- Department of Radiation Oncology, Comprehensive Cancer Center, Helsinki University Central Hospital, P.O. Box 180, Helsinki 00029 HUS, Finland and Department of Medical Physics, Oncology Services, Vejle Hospital, Kabbeltoft 25, Vejle DK-7100, Denmark
| | - Leonard Wee
- Department of Medical Physics, Oncology Services, Vejle Hospital, Kabbeltoft 25, Vejle DK-7100, Denmark and Danish Colorectal Cancer Centre South, Vejle Hospital, Kabbeltoft 25, Vejle DK-7100, Denmark
| | - Juha Korhonen
- Department of Radiation Oncology, Comprehensive Cancer Center, Helsinki University Central Hospital, P.O. Box 180, Helsinki 00029 HUS, Finland; Danish Colorectal Cancer Centre South, Vejle Hospital, Kabbeltoft 25, Vejle DK-7100, Denmark; and Department of Radiology, Helsinki University Central Hospital, P.O. Box 180, Helsinki 00029 HUS, Finland
| |
Collapse
|
126
|
Wang Y, Mazur TR, Green O, Hu Y, Li H, Rodriguez V, Wooten HO, Yang D, Zhao T, Mutic S, Li HH. A GPU-accelerated Monte Carlo dose calculation platform and its application toward validating an MRI-guided radiation therapy beam model. Med Phys 2017; 43:4040. [PMID: 27370123 DOI: 10.1118/1.4953198] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on penelope and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. METHODS penelope was first translated from fortran to c++ and the result was confirmed to produce equivalent results to the original code. The c++ code was then adapted to cuda in a workflow optimized for GPU architecture. The original code was expanded to include voxelized transport with Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gpenelope highly user-friendly. Moreover, the vendor-provided MRIdian head model was incorporated into the code in an effort to apply gpenelope as both an accurate and rapid dose validation system. A set of experimental measurements were performed on the MRIdian system to examine the accuracy of both the head model and gpenelope. Ultimately, gpenelope was applied toward independent validation of patient doses calculated by MRIdian's kmc. RESULTS An acceleration factor of 152 was achieved in comparison to the original single-thread fortran implementation with the original accuracy being preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen(1), mediastinum (1), and breast (1), the MRIdian dose calculation engine agrees with gpenelope with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). CONCLUSIONS A Monte Carlo simulation platform was developed based on a GPU- accelerated version of penelope. This platform was used to validate that both the vendor-provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this platform will include dose validation and accumulation, IMRT optimization, and dosimetry system modeling for next generation MR-IGRT systems.
Collapse
Affiliation(s)
- Yuhe Wang
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - Thomas R Mazur
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - Olga Green
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - Yanle Hu
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - Hua Li
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - Vivian Rodriguez
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - H Omar Wooten
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - Deshan Yang
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - Tianyu Zhao
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - Sasa Mutic
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| | - H Harold Li
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110
| |
Collapse
|
127
|
Andreychenko A, Kroon PS, Maspero M, Jürgenliemk-Schulz I, De Leeuw AAC, Lam MGEH, Lagendijk JJW, van den Berg CAT. The feasibility of semi-automatically generated red bone marrow segmentations based on MR-only for patients with gynecologic cancer. Radiother Oncol 2017; 123:164-168. [PMID: 28238449 DOI: 10.1016/j.radonc.2017.01.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Revised: 01/26/2017] [Accepted: 01/29/2017] [Indexed: 10/20/2022]
Abstract
PURPOSE For patients with cervical cancer the delivery of chemotherapy with radiotherapy improves survival compared with radiotherapy alone. However, high rates of acute hematologic toxicity occur when combining both therapies due to the damage of the red bone marrow (RBM). This study aimed to reduce the radiation damage to the RBM. A tool has been developed for semi-automatic delineation of the red bone marrow based on MR-only. This delineation can be included into the treatment planning process to reduce the volume of RBM irradiated in patients receiving pelvic radiation therapy. METHODS 13 patients with cervical cancer were enrolled. All the patients underwent MR, CT and FDG-PET imaging. A tool for RBM determination from water and fat MR images was developed. Our MR-based RBM tool was optimized and validated with the FDG-PET scans of the patients. RESULTS Our tool identified RBM regions in the pelvic area. The mean total volume of these regions was 34% of the pelvic bone marrow. The corresponding SUV values based on the FDG-PET scans were above the reported threshold of active/red bone marrow. CONCLUSION This study shows that delineations of the RBM for the radiotherapy with RBM sparing can be generated semi-automatically using MR scans only.
Collapse
Affiliation(s)
- Anna Andreychenko
- Department of Radiotherapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands.
| | - Petra S Kroon
- Department of Radiotherapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands
| | - Matteo Maspero
- Department of Radiotherapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands
| | - Ina Jürgenliemk-Schulz
- Department of Radiotherapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands
| | - Astrid A C De Leeuw
- Department of Radiotherapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands
| | - Marnix G E H Lam
- Department of Nuclear Medicine, Center for Image Sciences, University Medical Center Utrecht, The Netherlands
| | - Jan J W Lagendijk
- Department of Radiotherapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands
| | - Cornelis A T van den Berg
- Department of Radiotherapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands
| |
Collapse
|
128
|
Feygelman V, Lohr F, Orton CG. The future of MRI in radiation therapy belongs to integrated MRI-linac systems, not the standalone MRI-Sim. Med Phys 2017; 44:791-794. [DOI: 10.1002/mp.12090] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2016] [Accepted: 12/29/2016] [Indexed: 11/08/2022] Open
Affiliation(s)
- Vladimir Feygelman
- Department of Radiation Oncology; H. Lee Moffitt Cancer Center; Tampa FL 33612 USA
| | - Frank Lohr
- Dipartimento di Oncologia; Az.Ospedaliero-Universitaria di Modena; Modena 41110 Italy
| | | |
Collapse
|
129
|
Edmund JM, Nyholm T. A review of substitute CT generation for MRI-only radiation therapy. Radiat Oncol 2017; 12:28. [PMID: 28126030 PMCID: PMC5270229 DOI: 10.1186/s13014-016-0747-y] [Citation(s) in RCA: 243] [Impact Index Per Article: 34.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Accepted: 12/21/2016] [Indexed: 12/13/2022] Open
Abstract
Radiotherapy based on magnetic resonance imaging as the sole modality (MRI-only RT) is an area of growing scientific interest due to the increasing use of MRI for both target and normal tissue delineation and the development of MR based delivery systems. One major issue in MRI-only RT is the assignment of electron densities (ED) to MRI scans for dose calculation and a similar need for attenuation correction can be found for hybrid PET/MR systems. The ED assigned MRI scan is here named a substitute CT (sCT). In this review, we report on a collection of typical performance values for a number of main approaches encountered in the literature for sCT generation as compared to CT. A literature search in the Scopus database resulted in 254 papers which were included in this investigation. A final number of 50 contributions which fulfilled all inclusion criteria were categorized according to applied method, MRI sequence/contrast involved, number of subjects included and anatomical site investigated. The latter included brain, torso, prostate and phantoms. The contributions geometric and/or dosimetric performance metrics were also noted. The majority of studies are carried out on the brain for 5–10 patients with PET/MR applications in mind using a voxel based method. T1 weighted images are most commonly applied. The overall dosimetric agreement is in the order of 0.3–2.5%. A strict gamma criterion of 1% and 1mm has a range of passing rates from 68 to 94% while less strict criteria show pass rates > 98%. The mean absolute error (MAE) is between 80 and 200 HU for the brain and around 40 HU for the prostate. The Dice score for bone is between 0.5 and 0.95. The specificity and sensitivity is reported in the upper 80s% for both quantities and correctly classified voxels average around 84%. The review shows that a variety of promising approaches exist that seem clinical acceptable even with standard clinical MRI sequences. A consistent reference frame for method benchmarking is probably necessary to move the field further towards a widespread clinical implementation.
Collapse
Affiliation(s)
- Jens M Edmund
- Radiotherapy Research Unit, Department of Oncology, Herlev & Gentofte Hospital, Copenhagen University, Herlev, Denmark. .,Niels Bohr Institute, Copenhagen University, Copenhagen, Denmark.
| | - Tufve Nyholm
- Department of Radiation Sciences, Umeå University, Umeå, SE-901 87, Sweden.,Medical Radiation Physics, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
| |
Collapse
|
130
|
Schellhammer SM, Hoffmann AL. Prediction and compensation of magnetic beam deflection in MR-integrated proton therapy: a method optimized regarding accuracy, versatility and speed. Phys Med Biol 2017; 62:1548-1564. [DOI: 10.1088/1361-6560/62/4/1548] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
131
|
Pulse sequence considerations for simulation and postimplant dosimetry of prostate brachytherapy. Brachytherapy 2017; 16:743-753. [PMID: 28063817 DOI: 10.1016/j.brachy.2016.11.014] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2016] [Revised: 11/24/2016] [Accepted: 11/28/2016] [Indexed: 11/21/2022]
Abstract
PURPOSE The purpose of this work is to present a brief review of MRI physics principles pertinent to prostate brachytherapy, and a summary of our experience in optimizing protocols for prostate brachytherapy applications. METHODS AND MATERIALS We summarized essential MR imaging characteristics and their interplays that need to be considered for prostate brachytherapy applications. These include spatial resolution, signal-to-noise ratio, image contrast, artifacts, geometric distortion, specific absorption rate, and total scan time. We further described the optimization of the protocols for three pulse sequences: three-dimensional (3D) fast-spoiled gradient echo sequence for T1-weighted imaging, 3D fast-spin echo sequence for T2-weighted imaging, and 3D fast imaging in steady-state precession sequence for combined T1 and T2-weighed imaging. The utilization of an endorectal coil was also described. RESULTS Using the optimized protocols, we acquired high-quality images of the entire prostate within 3-5 minutes for each sequence. These images display the desired image contrasts and a spatial resolution that is equal to or better than 0.59 mm × 0.73 mm × 1.2 mm. While 3D fast-spoiled gradient echo sequence and 3D fast-spin echo sequence depict radioactive seed markers and anatomic structures separately, 3D fast imaging in steady-state precession sequence demonstrates great promise for imaging both seed markers and prostate anatomy simultaneously in a single acquisition. CONCLUSIONS We have optimized current MRI protocols and demonstrated that the anatomic structures and positive contrast radioactive seed markers for prostate post-implant dosimetry can be adequately imaged either separately or simultaneously using different pulse sequences within a total scan time of 3-5 minutes each.
Collapse
|
132
|
Lundman JA, Bylund M, Garpebring A, Thellenberg Karlsson C, Nyholm T. Patient-induced susceptibility effects simulation in magnetic resonance imaging. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2017. [DOI: 10.1016/j.phro.2017.02.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
133
|
Initial experiments with gel-water: towards MRI-linac dosimetry and imaging. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2016; 39:921-932. [PMID: 27815727 DOI: 10.1007/s13246-016-0495-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Accepted: 10/25/2016] [Indexed: 10/20/2022]
Abstract
Tracking the position of a moving radiation detector in time and space during data acquisition can replicate 4D image-guided radiotherapy (4DIGRT). Magnetic resonance imaging (MRI)-linacs need MRI-visible detectors to achieve this, however, imaging solid phantoms is an issue. Hence, gel-water, a material that provides signal for MRI-visibility, and which will in future work, replace solid water for an MRI-linac 4DIGRT quality assurance tool, is discussed. MR and CT images of gel-water were acquired for visualisation and electron density verification. Characterisation of gel-water at 0 T was compared to Gammex-RMI solid water, using MagicPlate-512 (M512) and RMI Attix chamber; this included percentage depth dose, tissue-phantom ratio (TPR20/10), tissue-maximum ratio (TMR), profiles, output factors, and a gamma analysis to investigate field penumbral differences. MR images of a non-powered detector in gel-water demonstrated detector visualisation. The CT-determined gel-water electron density agreed with the calculated value of 1.01. Gel-water depth dose data demonstrated a maximum deviation of 0.7% from solid water for M512 and 2.4% for the Attix chamber, and by 2.1% for TPR20/10 and 1.0% for TMR. FWHM and output factor differences between materials were ≤0.3 and ≤1.4%. M512 data passed gamma analysis with 100% within 2%, 2 mm tolerance for multileaf collimator defined fields. Gel-water was shown to be tissue-equivalent for dosimetry and a feasible option to replace solid water.
Collapse
|
134
|
Ireland R, Tahir B, Wild J, Lee C, Hatton M. Functional Image-guided Radiotherapy Planning for Normal Lung Avoidance. Clin Oncol (R Coll Radiol) 2016; 28:695-707. [DOI: 10.1016/j.clon.2016.08.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Revised: 07/19/2016] [Accepted: 07/20/2016] [Indexed: 12/25/2022]
|
135
|
Tavallaei MA, Johnson PM, Liu J, Drangova M. Design and evaluation of an MRI-compatible linear motion stage. Med Phys 2016; 43:62. [PMID: 26745900 DOI: 10.1118/1.4937780] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
PURPOSE To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actuated with an ultrasonic motor. The stage can be positioned at arbitrary positions and orientations inside the scanner bore to move, push, or pull arbitrary phantoms. Using optical trackers, measuring microscopes, and navigators, the accuracy of the stage in motion control was evaluated. Also, the effect of the stage on image signal-to-noise ratio (SNR), artifacts, and B0 field homogeneity was evaluated. RESULTS The error of the stage in reaching fixed positions was 0.025 ± 0.021 mm. In execution of dynamic motion profiles, the worst-case normalized root mean squared error was below 7% (for frequencies below 0.33 Hz). Experiments demonstrated that the stage did not introduce artifacts nor did it degrade the image SNR. The effect of the stage on the B0 field was less than 2 ppm. CONCLUSIONS The results of the experiments indicate that the proposed system is MRI-compatible and can create reliable and reproducible motion that may be used for validation and assessment of motion related MRI applications.
Collapse
Affiliation(s)
- Mohammad Ali Tavallaei
- Imaging Research Laboratories, Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 5B7, Canada and Biomedical Engineering Graduate Program, The University of Western Ontario, London, Ontario N6A 5B9, Canada
| | - Patricia M Johnson
- Imaging Research Laboratories, Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 5B7, Canada and Department of Medical Biophysics, Schulich School of Medicine & Dentistry, The University of Western Ontario, London, Ontario N6A 5C1, Canada
| | - Junmin Liu
- Imaging Research Laboratories, Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 5B7, Canada
| | - Maria Drangova
- Imaging Research Laboratories, Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 5B7, Canada; Biomedical Engineering Graduate Program, The University of Western Ontario, London, Ontario N6A 5B9, Canada; and Department of Medical Biophysics, Schulich School of Medicine & Dentistry, The University of Western Ontario, London, Ontario N6A 5C1, Canada
| |
Collapse
|
136
|
Model-Based Regularisation for Respiratory Motion Estimation with Sparse Features in Image-Guided Interventions. ACTA ACUST UNITED AC 2016. [DOI: 10.1007/978-3-319-46726-9_11] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
137
|
Lagendijk JJW, van Vulpen M, Raaymakers BW. The development of the MRI linac system for online MRI-guided radiotherapy: a clinical update. J Intern Med 2016; 280:203-8. [PMID: 27197553 DOI: 10.1111/joim.12516] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- J J W Lagendijk
- Department of Radiotherapy, Centre for Image Sciences, UMC Utrecht, Utrecht, the Netherlands
| | - M van Vulpen
- Department of Radiotherapy, Centre for Image Sciences, UMC Utrecht, Utrecht, the Netherlands
| | - B W Raaymakers
- Department of Radiotherapy, Centre for Image Sciences, UMC Utrecht, Utrecht, the Netherlands
| |
Collapse
|
138
|
Stemkens B, Tijssen RHN, de Senneville BD, Lagendijk JJW, van den Berg CAT. Image-driven, model-based 3D abdominal motion estimation for MR-guided radiotherapy. Phys Med Biol 2016; 61:5335-55. [DOI: 10.1088/0031-9155/61/14/5335] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
139
|
de Prez L, de Pooter J, Jansen B, Aalbers T. A water calorimeter for on-site absorbed dose to water calibrations in60Co and MV-photon beams including MRI incorporated treatment equipment. Phys Med Biol 2016; 61:5051-76. [DOI: 10.1088/0031-9155/61/13/5051] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
140
|
Feng Y, Guo H, Zhang H, Li C, Sun L, Mutic S, Ji S, Hu Y. A modified fuzzy C-means method for segmenting MR images using non-local information. Technol Health Care 2016; 24 Suppl 2:S785-93. [DOI: 10.3233/thc-161208] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Yuan Feng
- School of Mechanical and Electronic Engineering, Soochow University, Suzhou, Jiangsu, China
- Robotics and Microsystems Center, Soochow University, Suzhou, Jiangsu, China
| | - Hao Guo
- School of Mechanical and Electronic Engineering, Soochow University, Suzhou, Jiangsu, China
- Robotics and Microsystems Center, Soochow University, Suzhou, Jiangsu, China
| | - Hongmiao Zhang
- School of Mechanical and Electronic Engineering, Soochow University, Suzhou, Jiangsu, China
- Robotics and Microsystems Center, Soochow University, Suzhou, Jiangsu, China
| | - Chungang Li
- School of Mechanical and Electronic Engineering, Soochow University, Suzhou, Jiangsu, China
- Robotics and Microsystems Center, Soochow University, Suzhou, Jiangsu, China
| | - Lining Sun
- School of Mechanical and Electronic Engineering, Soochow University, Suzhou, Jiangsu, China
- Robotics and Microsystems Center, Soochow University, Suzhou, Jiangsu, China
| | - Sasa Mutic
- Department of Radiation Oncology, Washington University, St. Louis, MO, USA
| | - Songbai Ji
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA
| | - Yanle Hu
- Department of Radiation Oncology, Washington University, St. Louis, MO, USA
- Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, USA
| |
Collapse
|
141
|
van Vulpen M, Wang L, Orton CG. Within the next five years, adaptive hypofractionation will become the most common form of radiotherapy. Med Phys 2016; 43:3941. [DOI: 10.1118/1.4951735] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
|
142
|
Feng Y, Kawrakow I, Olsen J, Parikh PJ, Noel C, Wooten O, Du D, Mutic S, Hu Y. A comparative study of automatic image segmentation algorithms for target tracking in MR-IGRT. J Appl Clin Med Phys 2016; 17:441-460. [PMID: 27074465 PMCID: PMC5875567 DOI: 10.1120/jacmp.v17i2.5820] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Revised: 11/18/2015] [Accepted: 11/11/2015] [Indexed: 12/02/2022] Open
Abstract
On-board magnetic resonance (MR) image guidance during radiation therapy offers the potential for more accurate treatment delivery. To utilize the real-time image information, a crucial prerequisite is the ability to successfully segment and track regions of interest (ROI). The purpose of this work is to evaluate the performance of different segmentation algorithms using motion images (4 frames per second) acquired using a MR image-guided radiotherapy (MR-IGRT) system. Manual con-tours of the kidney, bladder, duodenum, and a liver tumor by an experienced radiation oncologist were used as the ground truth for performance evaluation. Besides the manual segmentation, images were automatically segmented using thresholding, fuzzy k-means (FKM), k-harmonic means (KHM), and reaction-diffusion level set evolution (RD-LSE) algorithms, as well as the tissue tracking algorithm provided by the ViewRay treatment planning and delivery system (VR-TPDS). The performance of the five algorithms was evaluated quantitatively by comparing with the manual segmentation using the Dice coefficient and target registration error (TRE) measured as the distance between the centroid of the manual ROI and the centroid of the automatically segmented ROI. All methods were able to successfully segment the bladder and the kidney, but only FKM, KHM, and VR-TPDS were able to segment the liver tumor and the duodenum. The performance of the thresholding, FKM, KHM, and RD-LSE algorithms degraded as the local image contrast decreased, whereas the performance of the VP-TPDS method was nearly independent of local image contrast due to the reference registration algorithm. For segmenting high-contrast images (i.e., kidney), the thresholding method provided the best speed (< 1 ms) with a satisfying accuracy (Dice = 0.95). When the image contrast was low, the VR-TPDS method had the best automatic contour. Results suggest an image quality determination procedure before segmentation and a combination of different methods for optimal segmentation with the on-board MR-IGRT system.
Collapse
Affiliation(s)
- Yuan Feng
- Soochow University; Washington University School of Medicine; University of Texas at Austin.
| | | | | | | | | | | | | | | | | |
Collapse
|
143
|
Stemkens B, Sbrizzi A, Andreychenko AA, Crijns SPM, Lagendijk JJW, van den Berg CAT, Tijssen RHN. An optimization framework to maximize signal-to-noise ratio in simultaneous multi-slice body imaging. NMR IN BIOMEDICINE 2016; 29:275-283. [PMID: 26684245 DOI: 10.1002/nbm.3457] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2015] [Revised: 10/17/2015] [Accepted: 11/10/2015] [Indexed: 06/05/2023]
Abstract
Parallel imaging is essential for the acceleration of abdominal and pelvic 2D multi-slice imaging, in order to reduce scan time and mitigate motion artifacts. Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration (CAIPIRINHA) accelerated imaging has been shown to increase the signal-to-noise ratio (SNR) significantly compared with in-plane parallel imaging with similar acceleration. We hypothesize that for CAIPIRINHA-accelerated abdominal imaging the consistency of image quality and SNR is more difficult to achieve due to the subject-specific coil sensitivity profiles, caused by (1) flexible coil placement; (2) variations in anatomy; and (3) variations in scan coverage along the superior-inferior direction. To test this, a mathematical framework is introduced that calculates the (retained) SNR for in-plane and simultaneous multi-slice (SMS)-accelerated acquisitions. Moreover, this framework was used to optimize the sampling pattern by maximizing the local SNR within a region of interest (ROI) through non-linear, RF-induced CAIPIRINHA slice shifts. The framework was evaluated on 14 healthy subjects and the optimized sampling pattern was compared with in-plane acceleration and CAIPIRINHA acceleration with linear slice shifts, which are primarily used in brain imaging. We demonstrate that the field of view (FOV) in the superior-inferior direction, the coil positioning and the individual anatomy have a large impact on the image SNR (changes up to 50% for varying coil positions and 40% differences between subjects) and image artifacts for simultaneous multi-slice acceleration. Consequently, sampling patterns have to be optimized for acquisitions employing different FOVs and ideally on an individual basis. Optimization of the sampling pattern, which exploits non-linear shifts between slices, showed a considerable SNR increase (10-30%) for higher acceleration factors. The framework outlined in this article can be used to optimize sampling patterns for a broad range of accelerated body acquisitions on an individual basis. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Bjorn Stemkens
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Alessandro Sbrizzi
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Anna A Andreychenko
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Sjoerd P M Crijns
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Jan J W Lagendijk
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| | | | - Rob H N Tijssen
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| |
Collapse
|
144
|
Bukhari W, Hong SM. Real-time prediction and gating of respiratory motion in 3D space using extended Kalman filters and Gaussian process regression network. Phys Med Biol 2016; 61:1947-67. [DOI: 10.1088/0031-9155/61/5/1947] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
145
|
Combs SE, Nüsslin F, Wilkens JJ. Individualized radiotherapy by combining high-end irradiation and magnetic resonance imaging. Strahlenther Onkol 2016; 192:209-15. [PMID: 26852244 DOI: 10.1007/s00066-016-0944-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Accepted: 01/14/2016] [Indexed: 01/22/2023]
Abstract
Image-guided radiotherapy (IGRT) has been integrated into daily clinical routine and can today be considered the standard especially with high-dose radiotherapy. Currently imaging is based on MV- or kV-CT, which has clear limitations especially in soft-tissue contrast. Thus, combination of magnetic resonance (MR) imaging and high-end radiotherapy opens a new horizon. The intricate technical properties of MR imagers pose a challenge to technology when combined with radiation technology. Several solutions that are almost ready for routine clinical application have been developed. The clinical questions include dose-escalation strategies, monitoring of changes during treatment as well as imaging without additional radiation exposure during treatment.
Collapse
Affiliation(s)
- Stephanie E Combs
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Germany. .,Institute of Innovative Radiotherapy (iRT), Department of Radiation Sciences (DRS), Helmholtz Zentrum München, Ingolstädter Landstraße 1, 85764, Neuherberg, Germany.
| | - Fridtjof Nüsslin
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Germany
| | - Jan J Wilkens
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Germany.,Institute of Innovative Radiotherapy (iRT), Department of Radiation Sciences (DRS), Helmholtz Zentrum München, Ingolstädter Landstraße 1, 85764, Neuherberg, Germany
| |
Collapse
|
146
|
Niebuhr NI, Johnen W, Güldaglar T, Runz A, Echner G, Mann P, Möhler C, Pfaffenberger A, Jäkel O, Greilich S. Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy. Med Phys 2016; 43:908-16. [DOI: 10.1118/1.4939874] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
147
|
Andreychenko A, Raaijmakers A, Sbrizzi A, Crijns S, Lagendijk J, Luijten P, van den Berg C. Thermal noise variance of a receive radiofrequency coil as a respiratory motion sensor. Magn Reson Med 2016; 77:221-228. [DOI: 10.1002/mrm.26108] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Revised: 11/27/2015] [Accepted: 12/08/2015] [Indexed: 01/26/2023]
Affiliation(s)
- A. Andreychenko
- Imaging DivisionUniversity Medical Center Utrecht Netherlands
| | | | - A. Sbrizzi
- Imaging DivisionUniversity Medical Center Utrecht Netherlands
| | - S.P.M. Crijns
- Imaging DivisionUniversity Medical Center Utrecht Netherlands
| | | | - P.R. Luijten
- Imaging DivisionUniversity Medical Center Utrecht Netherlands
| | | |
Collapse
|
148
|
Seregni M, Paganelli C, Lee D, Greer PB, Baroni G, Keall PJ, Riboldi M. Motion prediction in MRI-guided radiotherapy based on interleaved orthogonal cine-MRI. Phys Med Biol 2016; 61:872-87. [DOI: 10.1088/0031-9155/61/2/872] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
149
|
Abstract
The use of magnetic resonance imaging (MRI) in radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimized, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT.
Collapse
Affiliation(s)
- Maria A Schmidt
- Cancer Research UK Cancer Imaging Centre, Royal Marsden Hospital and the Institute of Cancer Research, Downs Road, Sutton, Surrey, SM2 5PT, UK
| | | |
Collapse
|
150
|
Kessel KA, Combs SE. Data management, documentation and analysis systems in radiation oncology: a multi-institutional survey. Radiat Oncol 2015; 10:230. [PMID: 26572494 PMCID: PMC4647666 DOI: 10.1186/s13014-015-0543-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Accepted: 11/11/2015] [Indexed: 01/05/2023] Open
Abstract
Introduction Recently, information availability has become more elaborate and widespread, and treatment decisions are based on a multitude of factors. Gathering relevant data, also referred to as Big Data, is therefore critical for reaching the best patient care, and enhancing interdisciplinary and clinical research. Combining patient data from all involved systems is essential to prepare unstructured data for analyses. This demands special coordination in data management. Our study aims to characterize current developments in German-speaking hospital departments and practices. We successfully conducted the survey with the members of the Deutsche Gesellschaft für Radioonkologie (DEGRO). Methods A questionnaire was developed consisting of 17 questions related to data management, documentation and clinical trial analyses, reflecting the clinical topics such as basic patient information, imaging, follow-up information as well as connection of documentation tools with radiooncological treatment planning machines. Results A total of 44 institutions completed the online survey (University hospitals n = 17, hospitals n = 13, practices/institutes n = 14). University hospitals, community hospitals and private practices are equally equipped concerning IT infrastructure for clinical use. However, private practices have a low interest in research work. All respondents stated the biggest obstacles about introducing a documentation system into their unit lie in funding and support of the central IT departments. Only 27 % (12/44) of responsible persons are specialists for documentation and data management. Conclusion Our study gives an understanding of the challenges and solutions we need to be looking at for medical data storage. In the future, inter-departmental cross-links will enable the radiation oncology community to generate large-scale analyses. Electronic supplementary material The online version of this article (doi:10.1186/s13014-015-0543-0) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Kerstin A Kessel
- Department of Radiation Oncology, Technische Universität München (TUM), Ismaninger Straße 22, 81675, Munich, Germany. .,Institute of Innovative Radiotherapy (iRT), Helmholtz Zentrum München, Ingolstädter Landstraße 1, Neuherberg, Germany.
| | - Stephanie E Combs
- Department of Radiation Oncology, Technische Universität München (TUM), Ismaninger Straße 22, 81675, Munich, Germany. .,Institute of Innovative Radiotherapy (iRT), Helmholtz Zentrum München, Ingolstädter Landstraße 1, Neuherberg, Germany.
| |
Collapse
|