101
|
Bertrand J, Delfosse D, Mai V, Awiszus F, Harnisch K, Lohmann CH. Ceramic prosthesis surfaces induce an inflammatory cell response and fibrotic tissue changes. Bone Joint J 2018; 100-B:882-890. [DOI: 10.1302/0301-620x.100b7.bjj-2017-1590.r2] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims Early evidence has emerged suggesting that ceramic-on-ceramic articulations induce a different tissue reaction to ceramic-on-polyethylene and metal-on-metal bearings. Therefore, the aim of this study was to investigate the tissue reaction and cellular response to ceramic total hip arthroplasty (THA) materials in vitro, as well as the tissue reaction in capsular tissue after revision surgery of ceramic-on-ceramic THAs. Patients and Methods We investigated tissue collected at revision surgery from nine ceramic-on-ceramic articulations. we compared our findings with tissue obtained from five metal-on-metal THA revisions, four ceramic-on-polyethylene THAs, and four primary osteoarthritis synovial membranes. The latter were analyzed to assess the amount of tissue fibrosis that might have been present at the time of implantation to enable evaluation, in relation to implantation time, of any subsequent response in the tissues. Results There was a significant increase in tissue fibrosis with implantation time for all implant types tested. Interestingly, the tissue fibrosis in ceramic-on-ceramic THAs was significantly increased compared with metal-on-metal and ceramic-on-polyethylene. Additionally, we found ceramic wear particles in the periprosthetic tissue of ceramic implants. Fibroblasts responded with expression of cytokines when cultured on alumina-toughened zirconia (ATZ) and zirconia-toughened alumina (ZTA) ceramic surfaces. This response was more pronounced on ATZ ceramics compared with ZTA ceramics. The same inflammatory response was observed with peripheral blood mononuclear cells (PBMCs) cultured on ZTA and ATZ. Conclusion Our findings therefore, corroborate the previous findings that ceramic-on-ceramic periprosthetic revision tissue is fibrous and offer an explanation for this observation. We detected a long-term inflammatory response of PBMCs and an inflammatory response of fibroblasts to ATZ and ZTA ceramic. These findings partially explain the fibrotic tissue change in periprosthetic tissue of ceramic-on-ceramic bearings. Cite this article: Bone Joint J 2018;100-B:882–90.
Collapse
Affiliation(s)
- J. Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke
University, Magdeburg, Germany
| | | | - V. Mai
- Mathys AG Bettlach, Bettlach, Switzerland
| | - F. Awiszus
- Department of Orthopaedic Surgery, Otto-von-Guericke
University, Magdeburg, Germany
| | - K. Harnisch
- Institute for Materials and Joining Technology,
Otto-von-Guericke University, Magdeburg, Germany
| | - C. H. Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke
University, Magdeburg, Germany
| |
Collapse
|
102
|
Pemmari A, Leppänen T, Paukkeri EL, Eskelinen A, Moilanen T, Moilanen E. Gene expression in adverse reaction to metal debris around metal-on-metal arthroplasty: An RNA-Seq-based study. J Trace Elem Med Biol 2018; 48:149-156. [PMID: 29773173 DOI: 10.1016/j.jtemb.2018.03.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2017] [Revised: 03/15/2018] [Accepted: 03/16/2018] [Indexed: 01/23/2023]
Abstract
Joint replacement surgery is a standard treatment of advanced osteoarthritis (OA). Since 2000, cobalt-chromium (CoCr) metal-on-metal (MoM) implants were widely used in hip arthroplasties. Some patients developed "adverse reaction to metal debris" (ARMD) around the prosthesis, resulting in a need for revision surgery. In the present study, we addressed the pathogenesis of ARMD by genome-wide expression analysis. Pseudosynovial ARMD tissue was obtained from revision surgery of Articular Surface Replacement (ASR, DePuy, Warsaw, IN, USA) hip arthroplasties. Control tissue was 1) OA synovium from primary hip arthroplasties and 2) inflammatory pseudosynovial tissue from metal-on-plastic (MoP) implant revisions. In ARMD tissue, the expression of 1446 genes was significantly increased and that of 1881 decreased as compared to OA synovium. Genes associated with immune response, tissue development and certain leukocyte signaling pathways were enriched in the differently (FC > 2) expressed genes. The network analysis proposed PRKACB, CD2, CD52 and CD53 as the central regulators of the greatest (FC > 10) differences. When ARMD tissue was compared to MoP tissue, the expression of 16 genes was significantly higher and that of 21 lower. Many of these genes were associated with redox homeostasis, metal ion binding and transport, macrophage activation and apoptosis. Interestingly, genes central to myofibroblast (AEBP1 and DES) and osteoclast (CCL21, TREM2 and CKB) development were upregulated in the MoP tissue. In network analysis, IL8, NQO1, GSTT1 and HMOX1 were identified as potential central regulators of the changes. In conclusion, excessive amounts of CoCr debris produced by MoM hip implants induces in a group of patients a unique adverse reaction characterized with enhanced expression of genes associated with inflammation, redox homeostasis, metal ion binding and transport, macrophage activation and apoptosis.
Collapse
Affiliation(s)
- Antti Pemmari
- The Immunopharmacology Research Group, Faculty of Medicine and Life Sciences, University of Tampere and Tampere University Hospital, Tampere, Finland
| | - Tiina Leppänen
- The Immunopharmacology Research Group, Faculty of Medicine and Life Sciences, University of Tampere and Tampere University Hospital, Tampere, Finland
| | - Erja-Leena Paukkeri
- The Immunopharmacology Research Group, Faculty of Medicine and Life Sciences, University of Tampere and Tampere University Hospital, Tampere, Finland
| | | | - Teemu Moilanen
- The Immunopharmacology Research Group, Faculty of Medicine and Life Sciences, University of Tampere and Tampere University Hospital, Tampere, Finland; Coxa Hospital for Joint Replacement, Tampere, Finland
| | - Eeva Moilanen
- The Immunopharmacology Research Group, Faculty of Medicine and Life Sciences, University of Tampere and Tampere University Hospital, Tampere, Finland.
| |
Collapse
|
103
|
Heckmann ND, Sivasundaram L, Stefl MD, Kang HP, Basler ET, Lieberman JR. Total Hip Arthroplasty Bearing Surface Trends in the United States From 2007 to 2014: The Rise of Ceramic on Polyethylene. J Arthroplasty 2018; 33:1757-1763.e1. [PMID: 29429883 DOI: 10.1016/j.arth.2017.12.040] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 12/23/2017] [Accepted: 12/28/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Wear of the bearing surface is a critical element in determining the longevity of a total hip arthroplasty (THA). Over the past decade, concerns related to modern metal-on-metal (MoM) bearings and corrosion at the femoral head-neck interface have influenced surgeon selection of bearing surfaces. The purpose of this study is to analyze trends in THA bearing surface selection from 2007 through 2014 using a large national database. METHODS The Nationwide Inpatient Sample database was used to extract bearing surface data from patients who underwent a primary THA between 2007 and 2014. Patients were grouped by bearing surface type: metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), MoM, and ceramic-on-ceramic (CoC) bearings. Descriptive statistics were employed to describe trends. Univariate and multivariate analyses were performed to identify differences between bearing surface groups. RESULTS During the study period, 2,460,640 THA discharges were identified, of which 1,059,825 (43.1%) had bearing surface data. A total of 496,713 (46.9%) MoP, 307,907 (29.1%) CoP, 210,381 (19.9%) MoM, and 44,823 (4.2%) CoC cases were identified. MoM utilization peaked in 2008 representing 40.1% of THAs implanted that year and steadily declined to 4.0% in 2014. From 2007 to 2014, the use of CoP bearing surfaces increased from 11.1% of cases in 2007 to 50.8% of cases in 2014. In 2014, CoP utilization surpassed MoP which represented 42.1% of bearing surfaces that year. CONCLUSION During the study period, MoM bearing surfaces decreased precipitously, while CoP surpassed MoP as the most popular bearing surface used in a THA.
Collapse
Affiliation(s)
- Nathanael D Heckmann
- Department of Orthopaedic Surgery, Keck School of Medicine of USC, Los Angeles, California
| | | | - Michael D Stefl
- Department of Orthopaedic Surgery, Keck School of Medicine of USC, Los Angeles, California
| | - Hyunwoo Paco Kang
- Department of Orthopaedic Surgery, Keck School of Medicine of USC, Los Angeles, California
| | - Eric T Basler
- Department of Orthopaedic Surgery, Keck School of Medicine of USC, Los Angeles, California
| | - Jay R Lieberman
- Department of Orthopaedic Surgery, Keck School of Medicine of USC, Los Angeles, California
| |
Collapse
|
104
|
Matharu GS, Eskelinen A, Judge A, Pandit HG, Murray DW. Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris. Acta Orthop 2018; 89:278-288. [PMID: 29493348 PMCID: PMC6055775 DOI: 10.1080/17453674.2018.1440455] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The initial outcomes following metal-on-metal hip arthroplasty (MoMHA) revision surgery performed for adverse reactions to metal debris (ARMD) were poor. Furthermore, robust thresholds for performing ARMD revision are lacking. This article is the second of 2. The first article considered the various investigative modalities used during MoMHA patient surveillance (Matharu et al. 2018a ). The present article aims to provide a clinical update regarding ARMD revision surgery in MoMHA patients (hip resurfacing and large-diameter MoM total hip arthroplasty), with specific focus on the threshold for performing ARMD revision, the surgical strategy, and the outcomes following revision. Results and interpretation - The outcomes following ARMD revision surgery appear to have improved with time for several reasons, among them the introduction of regular patient surveillance and lowering of the threshold for performing revision. Furthermore, registry data suggest that outcomes following ARMD revision are influenced by modifiable factors (type of revision procedure and bearing surface implanted), meaning surgeons could potentially reduce failure rates. However, additional large multi-center studies are needed to develop robust thresholds for performing ARMD revision surgery, which will guide surgeons' treatment of MoMHA patients. The long-term systemic effects of metal ion exposure in patients with these implants must also be investigated, which will help establish whether there are any systemic reasons to recommend revision of MoMHAs.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom,Correspondence:
| | | | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
| | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
| |
Collapse
|
105
|
Comparison of Postoperative Complications Following Metal-on-Metal Total Hip Arthroplasty With Other Hip Bearings in Medicare Population. J Arthroplasty 2018; 33:1826-1832. [PMID: 29510952 DOI: 10.1016/j.arth.2018.01.066] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2016] [Revised: 01/18/2018] [Accepted: 01/25/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The use of metal-on-metal (MoM) hip bearings has declined in the recent years due to strong evidence of their high complication rates and early failure. Hip implants with highly cross-linked polyethylene liners and ceramic bearings have become the modern implants of choice. We sought to determine if MoM implants are associated with higher complication and revision rates when compared to other hip bearings in the Medicare population. METHODS We retrospectively reviewed a Medicare database (2005-2011) for patients who underwent a primary total hip arthroplasty with a MoM, metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), or ceramic-on-ceramic (CoC) implant (minimum 2 years of follow-up). Patient comorbidities and medical/surgical complication rates were analyzed at various time points postoperatively. RESULTS We identified 288,118 patients, including 81,520 patients with a MoM implant, 162,881 with MoP, 33,819 with CoP, and 9898 with CoC implant. Surgical complication rates were higher for MoM implants including infection, osteolysis/polywear, mechanical complications, and need for hip irrigation and debridement. Overall revision rates were significantly higher for MoM implants (5.28%) compared to MoP (4.28%, odds ratio [OR] 1.26, P < .001) and CoP (3.52%, OR 1.55, P < .001) but only by one to two percent. MoM revision rates were similar to CoC implants (4.94%, OR 1.00, P = .096). CONCLUSIONS MoM implants were associated with higher revision rates (5.28%) compared to MoP (4.28%) and CoP (3.52%) implants in the Medicare population. Both complication and revision rates were comparable to CoC implants.
Collapse
|
106
|
de Steiger R, Peng A, Lewis P, Graves S. What Is the Long-term Survival for Primary THA With Small-head Metal-on-metal Bearings? Clin Orthop Relat Res 2018; 476:1231-1237. [PMID: 29432270 PMCID: PMC6263567 DOI: 10.1007/s11999.0000000000000209] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Large-head metal-on-metal (MoM) bearing hip replacements have been shown to have a much higher rate of revision than other bearing surfaces. However, small-head (≤ 32 mm) MoM bearing surfaces have been in use for many years with several reports of satisfactory mid- to long-term survivorship. It is unclear whether the long-term survival of small-head MoM devices will continue to be satisfactory or whether the same concerns seen with the large-head MoM devices will ultimately become more prevalent. QUESTIONS/PURPOSES We analyzed a large national registry to ask: (1) What is the 15-year Kaplan-Meier survivorship of primary conventional THA using small-head (≤ 32 mm) MoM bearing surfaces compared with large-head MoM bearing surfaces in primary THA? (2) Is there an increased rate of revision for adverse reaction to metal debris (ARMD) in this group of patients over time? METHODS The Australian Orthopaedic Association National Joint Replacement Registry longitudinally maintains data on all primary and revision joint arthroplasties with nearly 100% capture. We analyzed all conventional primary THAs performed from Registry inception in September 1999 until December 31, 2015, in patients with a diagnosis of osteoarthritis and using MoM bearing surfaces ≤ 32 mm in diameter, defined as small-head MoM. The study group included 4838 primary THA with ≤ 32-mm MoM bearing surfaces. There were 2506 (51.8%) male patients and the median age of patients undergoing THA with a small-head MoM bearing surface was 64 years (range, 20-92 years of age). The outcome measure was the cumulative percent revision defined as the time to first revision using Kaplan-Meier estimates of survivorship at 15 years; reasons for revision and type of revision were also examined. We specifically investigated whether there was an increased risk of revision for ARMD in this MoM group compared with all other bearing surfaces. We compared these results with large-head MoM THAs (femoral head size > 32 mm). RESULTS The cumulative percent revision for small-head MoM designs at 15 years was 8.5% (95% confidence interval [CI], 7.3-9.9). The cumulative percent revision for large-head MoM at 14 years was 27.4% (95% CI, 24.8-30.2). Prostheses with a large-head MoM articulation have a higher rate of revision than small-head MoM bearing surfaces (hazard ratio after 6 years, 5.14; 95% CI, 4.1-6.5; p < 0.001). Over time, there was a gradual increase in the diagnosis of ARMD for small-head MoM and the cumulative incidence of revision for ARMD was 0.8% at 15 years. CONCLUSIONS Despite survival that is substantially greater than that of large-head MoM THAs, there has been a marked decrease in the use of small-head MoM designs in our registry. Although the reasons for this are likely multifactorial, the increasing incidence of revisions for ARMD among small-head MoM THAs is concerning. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Richard de Steiger
- R. de Steiger, Department of Surgery, Epworth Healthcare, University of Melbourne, Richmond, Victoria, Australia A. Peng, South Australian Health and Medical Research Institute, Adelaide, Australia P. Lewis, S. Graves, Australian Orthopaedic Association National Joint Replacement Registry, South Australian Health and Medical Research Institute, Adelaide, Australia This work was performed at the Australian Orthopaedic Association National Joint Replacement Registry, Adelaide, South Australia, Australia
| | | | | | | |
Collapse
|
107
|
Lehtovirta L, Reito A, Parkkinen J, Peräniemi S, Vepsäläinen J, Eskelinen A. Association between periprosthetic tissue metal content, whole blood and synovial fluid metal ion levels and histopathological findings in patients with failed metal-on-metal hip replacement. PLoS One 2018; 13:e0197614. [PMID: 29768492 PMCID: PMC5955572 DOI: 10.1371/journal.pone.0197614] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 05/04/2018] [Indexed: 02/08/2023] Open
Abstract
Adverse Reaction to Metal Debris (ARMD) is a major cause of implant failure leading to revision surgery in patients with metal-on-metal (MoM) hip arthroplasties. However, the pathogenesis and its association to implant wear are poorly understood and previous studies have yielded discrepant results. We sought to investigate the associations between histological findings, whole blood and synovial fluid metal ion concentrations and periprosthetic tissue metal concentrations in patients with MoM total hip replacements and hip resurfacings revised for ARMD. 107 hips in total were included in our study. Of these, 87 were total hip replacements and 20 were hip resurfacings, respectively. We found that whole blood, synovial fluid and periprosthetic tissue metal concentrations correlated poorly with histological findings. We suggest that the lack of a clear association between histological findings and wear measures in the present study as well as in previous studies is mostly influenced by variability in patient susceptibility. However, patients presenting with perivascular lymphocytic infiltration had lower chromium concentration in their periprosthetic tissues than patients with no perivascular lymphocytic infiltration. This may reflect the role of metal hypersensitivity in implant failure in these patients. Patients with total hip replacements evinced more necrosis and lymphocytic infiltration in their tissues than patients with hip resurfacings. This suggests that trunnion wear debris is more cytotoxic and/or immunogenic than bearing wear debris leading to higher failure rates seen in patients with total hip replacements.
Collapse
Affiliation(s)
- Lari Lehtovirta
- University of Tampere, Tampere, Finland
- Coxa Hospital for Joint Replacement, Tampere, Finland
- * E-mail:
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | | | | |
Collapse
|
108
|
Drynda S, Drynda A, Feuerstein B, Kekow J, Lohmann CH, Bertrand J. The effects of cobalt and chromium ions on transforming growth factor-beta patterns and mineralization in human osteoblast-like MG63 and SaOs-2 cells. J Biomed Mater Res A 2018; 106:2105-2115. [DOI: 10.1002/jbm.a.36409] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 03/11/2018] [Accepted: 03/15/2018] [Indexed: 01/04/2023]
Affiliation(s)
- Susanne Drynda
- Department of Orthopaedic Surgery; Otto-von-Guericke University; Magdeburg Germany
- Clinic for Rheumatology, Otto-von-Guericke University; Magdeburg Germany
| | - Andreas Drynda
- Department of Orthopaedic Surgery; Otto-von-Guericke University; Magdeburg Germany
| | - Bernd Feuerstein
- Department of Mechanical Engineering; Magdeburg-Stendal University of Applied Sciences; Magdeburg Germany
| | - Jörn Kekow
- Clinic for Rheumatology, Otto-von-Guericke University; Magdeburg Germany
| | - Christoph H. Lohmann
- Department of Orthopaedic Surgery; Otto-von-Guericke University; Magdeburg Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery; Otto-von-Guericke University; Magdeburg Germany
| |
Collapse
|
109
|
Høl PJ, Kristoffersen EK, Gjerdet NR, Pellowe AS. Novel Nanoparticulate and Ionic Titanium Antigens for Hypersensitivity Testing. Int J Mol Sci 2018; 19:E1101. [PMID: 29642398 PMCID: PMC5979587 DOI: 10.3390/ijms19041101] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 03/26/2018] [Accepted: 04/03/2018] [Indexed: 02/06/2023] Open
Abstract
Titanium is used in a wide variety of materials ranging from medical devices to materials used in everyday life. Adverse biological reactions that could occur in patients, consumers, and workers should be monitored and prevented. There is a lack of available agents to test and predict titanium-related hypersensitivity. The aim of this study was to develop two bioavailable titanium substances in ionic and nanoparticulate form to serve as antigens for hypersensitivity testing in vitro. Peripheral blood mononuclear cells from 20 test subjects were stimulated with the antigens and secretion of monocytic and lymphatic cytokines and chemokines were measured by a multiplex bead assay. Lymphocyte stimulation indices were also determined in a subset of test subjects by measuring CD69 and HLA-DR expression by flow cytometry. Cytokine profiling revealed that both antigens increased production of typical monocyte and macrophage secreted cytokines after 24 h, with significant increases in IL-1β, IL-7, IL-10, IL-12, IL-2R, IL-6, GM-CSF, TNF-α, IL-1RA, MIP-1α, MIP-1β, IFN-α, and IL-15. Lymphatic cytokines and chemokines were not significantly induced by activation. After seven days of stimulation, ionic-Ti (2.5 μg/mL) caused proliferation (stimulation index > 2) of CD4+ cells and CD8+ cells in all persons tested (N = 6), while titanium dioxide nanoparticles (50 μg/mL) only caused significant proliferation of CD4+ cells. Our preliminary results show that the experimental titanium antigens, especially the ionic form, induce a general inflammatory response in vitro. A relevant cohort of test subjects is required to further elucidate their potential for predictive hypersensitivity testing.
Collapse
Affiliation(s)
- Paul Johan Høl
- Department of Clinical Medicine, University of Bergen, N-5021 Bergen, Norway.
- Department of Orthopaedic Surgery, Haukeland University Hospital, Jonas Lies vei 87, N-5021 Bergen, Norway.
| | - Einar K Kristoffersen
- Department of Clinical Science, University of Bergen, N-5021 Bergen, Norway.
- Department of Immunology and Transfusion Medicine, Haukeland University Hospital, N-5021 Bergen, Norway.
| | - Nils Roar Gjerdet
- Department of Clinical Dentistry, University of Bergen, N-5009 Bergen, Norway.
| | - Amanda S Pellowe
- School of Engineering and Applied Sciences, Yale University, New Haven, CT 06511, USA.
| |
Collapse
|
110
|
Kim WY, Ko MS, Lee SW, Kim KS. Short-term Outcomes of Ceramic Coated Metal-on-Metal Large Head in Total Hip Replacement Arthroplasty. Hip Pelvis 2018; 30:12-17. [PMID: 29564292 PMCID: PMC5861020 DOI: 10.5371/hp.2018.30.1.12] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 12/11/2017] [Accepted: 12/21/2017] [Indexed: 11/29/2022] Open
Abstract
Purpose This study characterizes the short-term outcomes of ceramic coated metal-on-metal (MoM) large head total hip arthroplasty (THA) in prospectively selected patients aged 70 to 75 years. Materials and Methods Eighteen patients (18 hips) between the ages of 70 and 75-years old with THA using ceramic-coated MoM large heads between June 2014 and December 2014 were evaluated. We prospectively selected patients younger than 70 years for bipolar hemiarthroplasty and older than 75 years for conventional THA. There were one case of osteoarthritis, 8 cases of femur neck fracture, and 9 cases of intertrochanteric fracture. All patients underwent clinical and radiological follow-up at 6 weeks, 6 and 12 months, and every year postoperatively. The mean duration of follow-up was 24.2 months (range, 18–34 months). Results The average Harris hip score at the final follow-up was 81.0, except one case which was ultimately converted to conventional THA due to acetabular cup loosening. Radiographically, mean acetabular cup inclination was 45.8°(range, 38–56°) and anteversion was 20.1° (range, 11–25°). The average femoral head size was 48.7 mm. All stems were neutral-positioned except 1 varus-positioned stem. There was 1 case of a soft tissue infection, 3 patients complained of persistent groin pain, and no dislocations occurred. Conclusion Ceramic coated large MOM articulation (ACCIS) have many complications: cup loosening, groin pain, which can lead to fatal outcomes in the elderly patients. Especially in patients with communicated intertrochanter fracture (AO 31-A22, 23), careful attention should be paid to the choice of surgical option.
Collapse
Affiliation(s)
- Weon-Yoo Kim
- Department of Orthopedic Surgery, The Catholic University of Korea, Daejeon St. Mary's Hospital, Daejeon, Korea
| | - Myung-Sup Ko
- Department of Orthopedic Surgery, The Catholic University of Korea, Daejeon St. Mary's Hospital, Daejeon, Korea
| | - Se-Won Lee
- Department of Orthopedic Surgery, The Catholic University of Korea, Daejeon St. Mary's Hospital, Daejeon, Korea
| | - Kwang-Sub Kim
- Department of Orthopedic Surgery, The Catholic University of Korea, Daejeon St. Mary's Hospital, Daejeon, Korea
| |
Collapse
|
111
|
Uchihara Y, Grammatopoulos G, Munemoto M, Matharu G, Inagaki Y, Pandit H, Tanaka Y, Athanasou NA. Implant failure in bilateral metal-on-metal hip resurfacing arthroplasties: a clinical and pathological study. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2018; 29:28. [PMID: 29516273 PMCID: PMC5842269 DOI: 10.1007/s10856-018-6037-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2017] [Accepted: 02/22/2018] [Indexed: 06/13/2023]
Abstract
Metal-on-metal hip resurfacing arthroplasties (MoMHRAs) have a high failure rate due to pseudotumour formation. It is not certain whether pseudotumours in bilateral MoMHRAs form on the basis of an adverse reaction to metal debris (ARMD) that is entirely due to a local innate and adaptive immune response to Cobalt-Chrome (Co-Cr) wear particles. To determine if there is a systemic component to ARMD in bilateral MoMHRAs, we examined the histology of ARMD in unilateral and bilateral MoMHRAs revised for pseudotumour and determined whether implant survival differed between these two groups. Periprosthetic tissue specimens from 119 hips revised for pseudotumour were examined. These were derived from 109 patients including 10 patients with bilateral MoMHRAs and 99 with sunilateral MoMHRAs including a cohort of 20 patients with bilateral MoMHRAs that had undergone only one MoMHRA revision for pseudotumour. The mean time to revision for pseudotumour of unilateral and bilateral MoMHRAs was determined. The histology of periprosthetic tissue was examined for evidence of the innate and adaptive immune response and scored semi-quantitatively. There was no significant difference in histological features of the innate / adaptive response between Group 1 bilateral pseudotumours and Group 2 and Group 3 unilateral pseudotumours. Histological features, including ALVAL scores, were similar in the periprosthetic tissues of right and left hips in Group 1 bilateral MoMHRAs. The mean time to first revision for pseudotumour of bilateral MoMHRAs (6.59 years) was not decreased compared with unilateral MoMHRAs (5.66 years) or bilateral MoMHRAs that had only one revision (7.05 years). Right and left hip pseudotumours in bilateral MoMHRAs exhibit similar histological features of the innate and adaptive immune response. Mean implant survival is not decreased in bilateral compared with unilateral MoMHRA cases. The findings suggest that pseudotumour formation is due more to a local than a systemic innate /adaptive immune response to components of metal wear.
Collapse
Affiliation(s)
- Yoshinubo Uchihara
- Department of Orthopaedic Surgery, Nara Medical University, Shijocho 840, Kashihara, Nara, 634-8522, Japan
| | - George Grammatopoulos
- Nuffield Department of Orthopaedics, Rheumatology and Surgery, Nuffield Orthopaedic Centre, University of Oxford, Headington, Oxford, OX3 7HE, UK.
| | - Mitsuru Munemoto
- Department of Orthopaedic Surgery, Nara Medical University, Shijocho 840, Kashihara, Nara, 634-8522, Japan
| | - Gulraj Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Surgery, Nuffield Orthopaedic Centre, University of Oxford, Headington, Oxford, OX3 7HE, UK
| | - Yusuke Inagaki
- Department of Orthopaedic Surgery, Nara Medical University, Shijocho 840, Kashihara, Nara, 634-8522, Japan
| | - Hemant Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Surgery, Nuffield Orthopaedic Centre, University of Oxford, Headington, Oxford, OX3 7HE, UK
| | - Yasuhito Tanaka
- Department of Orthopaedic Surgery, Nara Medical University, Shijocho 840, Kashihara, Nara, 634-8522, Japan
| | - Nick A Athanasou
- Nuffield Department of Orthopaedics, Rheumatology and Surgery, Nuffield Orthopaedic Centre, University of Oxford, Headington, Oxford, OX3 7HE, UK.
| |
Collapse
|
112
|
Grote CW, Cowan PC, Anderson DW, Templeton KJ. Pseudotumor from Metal-on-Metal Total Hip Arthroplasty Causing Unilateral Leg Edema: Case Presentation and Literature Review. Biores Open Access 2018; 7:33-38. [PMID: 29607251 PMCID: PMC5870059 DOI: 10.1089/biores.2017.0035] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Metal-on-metal (MoM) total hip arthroplasty (THA) can be associated with adverse metal reactions, including pseudotumors. This case report describes a 58-year-old female with an MoM THA-related pseudotumor that caused unilateral leg edema from compression of her external iliac vein. After thorough preoperative workup to rule out infection and deep vein thrombosis and consultation with a vascular surgeon, the patient underwent revision THA and excision of her pseudotumor. She had complete resolution of her swelling at 4 years after surgery. Review of all available case reports for this rare complication revealed that almost all patients were female. All patients underwent revision THA, with resolution of their symptoms. Literature review demonstrates that women are disproportionally affected by complications associated with MoM THA. We recommend close monitoring of patients with MoM THA, particularly women, for development of adverse metal reactions.
Collapse
Affiliation(s)
- Caleb W Grote
- Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas City, Kansas
| | - Paul C Cowan
- Department of Orthopedic Surgery, Drisko, Fee and Parkins, Kansas City, Missouri
| | - David W Anderson
- Department of Orthopedic Surgery, Kansas City Joint Replacement at Menorah Medical Center, Overland Park, Kansas
| | - Kimberly J Templeton
- Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas City, Kansas
| |
Collapse
|
113
|
Bardakos NV. CORR Insights®: Frank Stinchfield Award: Identification of the At-risk Genotype for Development of Pseudotumors Around Metal-on-metal THAs. Clin Orthop Relat Res 2018; 476. [PMID: 29529652 PMCID: PMC6259710 DOI: 10.1007/s11999.0000000000000111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Affiliation(s)
- Nikolaos V Bardakos
- N. V. Bardakos Consultant Orthopaedic Surgeon, Asklepieion Hospital, Athens, Greece
| |
Collapse
|
114
|
Kilb BKJ, Kurmis AP, Parry M, Sherwood K, Keown P, Masri BA, Duncan CP, Garbuz DS. Frank Stinchfield Award: Identification of the At-risk Genotype for Development of Pseudotumors Around Metal-on-metal THAs. Clin Orthop Relat Res 2018; 476. [PMID: 29529651 PMCID: PMC6259707 DOI: 10.1007/s11999.0000000000000028] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Once touted as the future of hip arthroplasty, metal-on-metal (MoM) bearing surfaces have fallen sharply from favor with the emergence of a strong body of evidence demonstrating unacceptably high premature implant failure rates. The previously unpredictable development of adverse local tissue reactions (ALTRs) has been a substantive contributor to this. Although the underlying pathophysiology of these so-called "pseudotumors" is now well understood, the fundamental predisposing patient risk factors have remained elusive. QUESTIONS/PURPOSES The aim of this research, as a clinical-genotype correlation analysis, was to identify specific alleles (genes) associated with the development of ALTRs in patients with in situ MoM THAs. METHODS A case-control study of patients who received a large-head, primary MoM THA between 2005 and 2008 was performed with a minimum followup of 5 years. Twenty-six patients who had undergone revision of a primary MoM THA secondary to symptomatic ALTRs were recruited. The mean timeframe from primary MoM THA to symptomatic revision was 5.5 years (range, 1-10 years). Twenty-eight control subjects were randomly selected asymptomatic patients with no evidence of ALTRs on protocol-specific screening. Baseline demographics and high-resolution genotype (human leukocyte antigen [HLA] Class II) were collected for all patients. Cohorts were similar with respect to age at the time of primary MoM THA (mean, 54.8 versus 54.9 years, p = 0.95) and serum cobalt (mean, 5.5 versus 8.5 μg/L, p = 0.09) and chromium concentrations (mean, 2.9 versus 4.2 μg/L, p = 0.27). The association between genotype and revision surgery secondary to ALTRs was determined with gender as a covariate. RESULTS The prevalence of the risk genotype was 30% (16 of 54) among the entire cohort. Adjusting for sex, the odds of revision were 6.1 times greater among patients with the risk genotype present than among patients without (95% confidence interval [CI], 1.5-25.4; p = 0.01). Among females, the specificity of the risk genotype was 1.0 (95% CIexact, 0.5-1.0; pexact = 0.03), and for males, it was 0.8 (95% CIexact, 0.6-0.9; pexact < 0.01). CONCLUSIONS The findings of this study suggest that, among patients with a primary MoM THA, allelic variation within the HLA Class II loci may be a strong, independent risk factor associated with the need for subsequent revision surgery secondary to pseudotumor formation. CLINICAL RELEVANCE Given the hypothesis-generating nature of this novel undertaking, confirmatory prospective clinical studies are required to further elucidate this correlation and to explore the clinical utility of targeted genetic screening in this specific population. This research may, however, represent a key missing piece in the puzzle that is metal ion-induced pseudotumor formation.
Collapse
Affiliation(s)
- Brett K J Kilb
- B. K. J. Kilb, A. P. Kurmis, M. Parry, B. A. Masri, C. P. Duncan, D. S., Garbuz Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada K. Sherwood, P. Keown Department of Pathology (&) Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada P. Keown, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada A. P. Kurmis, Discipline of Medical Specialties, University of Adelaide, Adelaide, SA, Australia
| | | | | | | | | | | | | | | |
Collapse
|
115
|
|
116
|
Affiliation(s)
- Jukka Pajarinen
- a Department of Orthopaedic Surgery , Stanford University , Stanford , CA , USA
| | - Jiri Gallo
- b Department of Orthopaedics , Faculty of Medicine and Dentistry, Palacky University Olomouc , Czech Republic
| | - Michiaki Takagi
- c Department of Orthopaedic Surgery , Yamagata University Faculty of Medicine , Yamagata City , Yamagata , Japan
| | - Stuart B Goodman
- a Department of Orthopaedic Surgery , Stanford University , Stanford , CA , USA
| | | |
Collapse
|
117
|
Akil S, Newman JM, Shah NV, Ahmed N, Deshmukh AJ, Maheshwari AV. Metal hypersensitivity in total hip and knee arthroplasty: Current concepts. J Clin Orthop Trauma 2018; 9:3-6. [PMID: 29628676 PMCID: PMC5884053 DOI: 10.1016/j.jcot.2017.10.003] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 10/04/2017] [Accepted: 10/05/2017] [Indexed: 01/23/2023] Open
Abstract
Metal hypersensitivity (MHS) is a rare complication of total joint arthroplasty that has been linked to prosthetic device failure when other potential causes have been ruled out. The purpose of this review was to conduct an analysis of existing literature in order to get a better understanding of the pathophysiology, presentation, diagnosis, and management of MHS. It has been described as a type IV hypersensitivity reaction to the metals comprising prosthetic implants, often nickel and cobalt-chromium. Patients suffering from this condition have reported periprosthetic joint pain and swelling as well as cutaneous, eczematous dermatitis. There is no standard for diagnosis MHS, but tests such as patch testing and lymphocyte transformation testing have demonstrated utility, among others. Treatment options that have demonstrated success include administration of steroids and revision surgery, in which the existing metal implant is replaced with one of less allergenic materials. Moreover, the definitive resolution of symptoms has most commonly required revision surgery with the use of different implants. However, more studies are needed in order to understand the complexity of this subject.
Collapse
Affiliation(s)
- Samuel Akil
- Department of Orthopaedic Surgery, State University of New York (SUNY), Downstate Medical Center, Brooklyn, NY, USA
| | - Jared M. Newman
- Department of Orthopaedic Surgery, State University of New York (SUNY), Downstate Medical Center, Brooklyn, NY, USA
| | - Neil V. Shah
- Department of Orthopaedic Surgery, State University of New York (SUNY), Downstate Medical Center, Brooklyn, NY, USA
| | - Natasha Ahmed
- Saba University School of Medicine, Saba, Caribbean Netherlands, Netherlands
| | - Ajit J. Deshmukh
- Department of Orthopaedic Surgery, NYU Langone Medical Center, VA New York Harbor Healthcare System, New York, NY, USA
| | - Aditya V. Maheshwari
- Department of Orthopaedic Surgery, State University of New York (SUNY), Downstate Medical Center, Brooklyn, NY, USA,Correspondence to: Adult Reconstruction and Musculoskeletal Oncology Divisions SUNY Downstate Medical Center 450 Clarkson Ave., Box 30 Brooklyn, New York 11203, USA.
| |
Collapse
|
118
|
Effects of wear particles of polyether-ether-ketone and cobalt-chromium-molybdenum on CD4- and CD8-T-cell responses. Oncotarget 2017. [PMID: 29541407 PMCID: PMC5834256 DOI: 10.18632/oncotarget.23757] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
T-cells, second only to macrophages, are often considered as the potential cells involved in debris-related failure of arthroplasty. Here, we assessed the effects of particulate wear debris on T-cells and inflammatory reactions. Blood samples from 25 donors were incubated with polyether-ether-ketone (PEEK) and cobalt-chromium-molybdenum (CoCrMo) particles generated by custom cryo-milling and pulverization. The T-cell phenotypes were assessed using immunostaining and flow cytometry. For the in vivo study, 0.1 mL of each particle suspension (approximately 1.0 × 108 wear particles) was injected into murine knee joints; the synovium and spleen were collected one week after the operation for histological examination and immunofluorescence staining. The T-cell responses observed included low-level activation of Th1, Th2, Th17, and CD8+ pathways after 72 h of co-culture of the particles with peripheral blood mononuclear cells. Obvious CD8+ T-cell responses were observed in local synovium and peripheral spleen, with higher inflammatory cytokine expression in the CoCrMo group. Relatively minor cytotoxic and immunological reactions were observed in vitro, with PEEK and CoCrMo particle-induced immune responses being primarily mediated by CD8+ T-cells, rather than CD4+ T-cells, in vivo. Overall, PEEK wear particles induced fewer inflammatory reactions than CoCrMo particles. This study verified that PEEK was suitable as a potential alternative for metals in total knee replacements in terms of the immunological reaction to PEEK particles, and shed light on the effects of wear particles from polymer and metal-based implants on immune responses.
Collapse
|
119
|
Fernandes CJC, Bezerra F, do Carmo MDD, Feltran GS, Rossi MC, da Silva RA, Padilha PDM, Zambuzzi WF. CoCr-enriched medium modulates integrin-based downstream signaling and requires a set of inflammatory genes reprograming in vitro. J Biomed Mater Res A 2017; 106:839-849. [PMID: 28941043 DOI: 10.1002/jbm.a.36244] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 07/31/2017] [Accepted: 09/19/2017] [Indexed: 12/22/2022]
Abstract
Significant health concerns have been raised by the high levels of Cr and Co ions into whole blood as resulted of corrosion process released from biomedical implants, but very little is known about their biological behavior in governing cell metabolism. Thus, we prompted to address this issue by exploring the effects of CoCr enriched medium on both fibroblast and preosteoblast (pre-Ob) cells. First, we showed there is a significant difference in Co and Cr releasing dependent on engineered surface, it being even more released in dual acid-etching treating surface (named w/DAE) than the machined surfaces (named wo/DAE). Thereafter, we showed CoCr affects pre-osteoblast and fibroblast metabolism by dynamically modulating integrin-based downstream signaling (FAK, Src, Rac1, and Cofilin). Specifically on this matter, we have shown there is dynamic β1-integrin gene activation up 24 h in both preosteoblast and fibroblast. Our analysis showed also that both pre-Ob and fibroblast are important resource of proinflammatory cytokines when responding to CoCr enriched medium. In addition, survival-related signaling pathway was also affected interfering on survival and proliferating signal, mainly affecting CDK2, mapk-Erk and mapk-p38 phosphorylations, while AKT/PKB-related gene remained active. In addition, during cell adhesion PP2A (an important Ser/Thr phosphatase) was inactive in both cell lineages and it seems be a CoCr's molecular fingerprint, regulating specific metabolic pathways involved with cytoskeleton rearrangement. Altogether, our results showed for the first time CoCr affects cellular performance in vitro by modulating integrin activation-based downstream signaling and requiring a reprograming of inflammatory genes activations in vitro. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 839-849, 2018.
Collapse
Affiliation(s)
- Célio J C Fernandes
- Department of Chemistry and Biochemistry, Bioscience Institute, State University of São Paulo, UNESP, Campus Botucatu, Botucatu, São Paulo, Brazil
| | - Fabio Bezerra
- Department of Chemistry and Biochemistry, Bioscience Institute, State University of São Paulo, UNESP, Campus Botucatu, Botucatu, São Paulo, Brazil
| | - Maiara das D do Carmo
- Department of Chemistry and Biochemistry, Bioscience Institute, State University of São Paulo, UNESP, Campus Botucatu, Botucatu, São Paulo, Brazil
| | - Georgia S Feltran
- Department of Chemistry and Biochemistry, Bioscience Institute, State University of São Paulo, UNESP, Campus Botucatu, Botucatu, São Paulo, Brazil
| | - Mariana C Rossi
- Department of Chemistry and Biochemistry, Bioscience Institute, State University of São Paulo, UNESP, Campus Botucatu, Botucatu, São Paulo, Brazil
| | - Rodrigo A da Silva
- Department of Chemistry and Biochemistry, Bioscience Institute, State University of São Paulo, UNESP, Campus Botucatu, Botucatu, São Paulo, Brazil
| | - Pedro de M Padilha
- Department of Chemistry and Biochemistry, Bioscience Institute, State University of São Paulo, UNESP, Campus Botucatu, Botucatu, São Paulo, Brazil
| | - Willian F Zambuzzi
- Department of Chemistry and Biochemistry, Bioscience Institute, State University of São Paulo, UNESP, Campus Botucatu, Botucatu, São Paulo, Brazil
| |
Collapse
|
120
|
Ma Y, Zuo P, Nittka M, Cheng X, Shao H, Wang C. Comparisons of slice-encoding metal artifact correction and view-angle tilting magnetic resonance imaging and traditional digital radiography in evaluating chronic hip pain after total hip arthroplasty. J Orthop Translat 2017; 12:45-54. [PMID: 29662778 PMCID: PMC5866482 DOI: 10.1016/j.jot.2017.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Revised: 11/15/2017] [Accepted: 11/29/2017] [Indexed: 11/20/2022] Open
Abstract
Purpose The aims of this study were (1) to compare the areas of metal-induced artifacts and definition of periprosthetic structures between patients scanned with the slice-encoding metal artifact correction and view-angle tilting (SEMAC-VAT) turbo-spin-echo (TSE) prototype and those scanned with the standard TSE magnetic resonance (MR) sequences and (2) to further clarify the superiority of the SEMAC-VAT MR imaging technique at detecting lesions in patients after total hip arthroplasty (THA), compared with digital radiography (DR). Materials and methods A total of 38 consecutive patients who underwent THA were referred to MR imaging at our institution. All patients suffered from chronic hip pain postoperatively. Twenty-three patients of the 38 were examined with a 1.5-T MR scanner using a SEMAC-VAT TSE prototype and standard TSE sequence, and the remaining 15 patients were examined with the same 1.5-T MR scanner, but using the SEMAC-VAT TSE prototype only. The traditional DR imaging was also performed for all patients. Two radiologists then independently measured the area of metal-induced artifacts and evaluated the definition of both the acetabular and femoral zones based on a three-point scale. Finally, the positive findings of chronic hip pain after THA based on SEMAC-VAT TSE MR imaging and traditional DR imaging were compared and analysed. Results The areas of metal-induced artifacts were significantly smaller in the SEMAC-VAT TSE sequences than those in the standard TSE sequences for both the T1-weighted (p < 0.001) and T2-weighted (p < 0.001) turbo inversion recovery magnitude images. In addition, 28 patients showed a series of positive signs in the SEMAC-VAT images that were not observed in the traditional DR images. Conclusion Compared with the standard TSE MR imaging, SEMAC-VAT MR imaging significantly reduces metal-induced artifacts and might successfully detect most positive signs missed in the traditional DR images. Translational potential of this article The main objective of this research was to show that MR sequences from the SEMAC-VAT TSE prototype provide a significant advantage at detecting lesions in patients after THA because of the excellent soft-tissue resolution of the MR imaging. SEMAC-VAT MR can evaluate chronic hip pain after THA and determine the cause, which can help the clinician decide on whether a surgical revision is needed.
Collapse
Affiliation(s)
- Yimin Ma
- Department of Radiology, Jishuitan Hospital, Beijing, China
- Corresponding author.
| | - Panli Zuo
- Siemens Healthcare, MR Collaborations NE Asia, Beijing, China
| | | | | | - Hongyi Shao
- Department of Orthopedics, Jishuitan Hospital, Beijing, China
| | - Chen Wang
- Department of Radiology, Jishuitan Hospital, Beijing, China
| |
Collapse
|
121
|
Lehtovirta L, Reito A, Parkkinen J, Hothi H, Henckel J, Hart A, Eskelinen A. Analysis of bearing wear, whole blood and synovial fluid metal ion concentrations and histopathological findings in patients with failed ASR hip resurfacings. BMC Musculoskelet Disord 2017; 18:523. [PMID: 29228956 PMCID: PMC5725985 DOI: 10.1186/s12891-017-1894-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 12/04/2017] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Adverse Reaction to Metal Debris (ARMD) is still a major reason for revision surgeries in patients with metal-on-metal (MoM) hip replacements. ARMD consists of a wide range of alterations in periprosthetic tissues, most important of which are metallosis, inflammation, pseudotumors and necrosis. Studies investigating histopathological findings and their association to implant wear or indirect measures of wear have yielded inconsistent results. Therefore, we aimed to investigate bearing surface wear volume, whole blood and synovial fluid metal ion concentrations, histopathological findings in periprosthetic tissues and their associations. METHODS Seventy-eight patients with 85 hips revised for ARMD were included in the study. Prior to revision surgery, all patients had whole blood chromium and cobalt ion levels assessed. In revision surgery, a synovial fluid sample was taken and analyzed for chromium and cobalt. Periprosthetic tissue samples were taken and analyzed for histopathological findings. Explanted implants were analyzed for bearing wear volume of both acetabular cup and femoral head components. RESULTS Volumetric wear of the failed components was highly variable. The total wear volume of the head and cup had a strong correlation with whole blood chromium and cobalt ion concentrations (Cr: ρ = 0.80, p < 0.001 and Co: ρ = 0.84, p < 0.001) and a bit weaker correlation with fluid chromium and cobalt ion concentrations (Cr: ρ = 0.50, p < 0.01 and Co: ρ = 0.41, p = 0.027). Most tissues displayed only low-to-moderate amounts of macrophages and lymphocytes. Total wear volume correlated with macrophage sheet thickness (ρ = 0.25, p = 0.020) and necrosis (ρ = 0.35, p < 0.01). Whole blood chromium and cobalt ion concentrations had similar correlations. Lymphocyte cuff thickness did not correlate with either total wear volume or whole blood metal ion concentrations, but correlated with the grade of necrosis. CONCLUSIONS Bearing wear volume correlated with blood metal ion levels and the degree of necrosis and macrophage infiltration in periprosthetic tissues suggesting a dose-response relationship. Whole blood metal ion levels are a useful tool for clinician to estimate bearing wear and subsequent tissue response.
Collapse
Affiliation(s)
- Lari Lehtovirta
- Faculty of Medicine, University of Tampere, Tampere, Finland
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | | | | | | |
Collapse
|
122
|
Bauer TW. CORR Insights ®: Current Pathologic Scoring Systems for Metal-on-metal THA Revisions are not Reproducible. Clin Orthop Relat Res 2017; 475:3012-3014. [PMID: 28956270 PMCID: PMC5670081 DOI: 10.1007/s11999-017-5512-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 09/22/2017] [Indexed: 01/31/2023]
Affiliation(s)
- Thomas W. Bauer
- 0000 0001 2285 8823grid.239915.5Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, 535 East 70th St., New York, NY 10021 USA
| |
Collapse
|
123
|
Current Pathologic Scoring Systems for Metal-on-metal THA Revisions are not Reproducible. Clin Orthop Relat Res 2017; 475:3005-3011. [PMID: 28688018 PMCID: PMC5670057 DOI: 10.1007/s11999-017-5432-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Accepted: 06/23/2017] [Indexed: 01/31/2023]
Abstract
BACKGROUND The aseptic lymphocyte vasculitis-associated lesion (ALVAL) score and the modified Oxford ALVAL score are frequently used scoring methods to evaluate the morphologic features of periprosthetic tissues around metal-on-metal (MoM) hip implants. Except for the initial studies of these two morphology scoring methods, to our knowledge, no other studies have reported on intraclass correlation coefficient (ICC) values for interobserver reliability of these scoring methods. QUESTIONS/PURPOSES Are the ALVAL and Oxford ALVAL scores reproducible? METHODS The periprosthetic tissue of 37 revisions of 36 patients with failed MoM THAs were independently scored by three experienced pathologists using ALVAL and Oxford ALVAL scoring methods. All patients were included who underwent revision surgery in our hospital until January 2013, with a large-head MoM prosthesis and also met the criteria: blood serum cobalt levels, available MRI scan, and intraarticular cobalt levels. The population included 26 patients with pseudotumors diagnosed by two radiologists using the method described by Matthies et al. The ALVAL describes morphologic features of the synovial lining, tissue organization, and inflammatory cell infiltrate in periprosthetic tissues. The Oxford-ALVAL score uses a semiquantitative measure of the immune response which should be easier to score. RESULTS The ALVAL score showed an ICC of 0.38 (95% CI, 0.18-0.58) (fair) for the sum score and this improved up to 0.50 (95% CI, 0.31-0.68) (moderate) using the modified Oxford ALVAL score. The individual parameters of the ALVAL score showed an ICC for the scoring of inflammatory infiltrate of 0.37 (95% CI, 0.17-0.57), an ICC of 0.32 (95% CI, 0.12-0.53) for the scoring of tissue organization, and an ICC of 0.14 (95% CI, -0.04 to 0.34) for synovial lining. CONCLUSIONS Scoring morphologic features of MoM tissue is not reproducible using the ALVAL score or the Oxford ALVAL score. This may reflect heterogeneous morphologic features in tumor tissue and between different tumor tissue samples that cannot be reliably quantified by pathologists using the parameters of these two scoring methods. An alternative, simplified scoring system should be developed to improve the interrater agreement. LEVEL OF EVIDENCE Level III, diagnostic study.
Collapse
|
124
|
Granchi D, Savarino LM, Ciapetti G, Baldini N. Biological effects of metal degradation in hip arthroplasties. Crit Rev Toxicol 2017; 48:170-193. [PMID: 29130357 DOI: 10.1080/10408444.2017.1392927] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|
125
|
Hannan R, Arora V, Beaver R, Harvie P. How should new orthopaedic implants be introduced: an example and recommendations for best practice. ANZ J Surg 2017; 88:284-289. [PMID: 29124832 DOI: 10.1111/ans.14234] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2017] [Revised: 07/14/2017] [Accepted: 08/14/2017] [Indexed: 10/18/2022]
Abstract
Continued advancements in orthopaedics have led to the development of many new implants; many of these are being utilized in clinical practice with little or no evidence base for their safety or effectiveness. Highly publicized failures in orthopaedic technology have led to an increased awareness of this issue in both medical and non-medical circles. In most cases, the significant harm caused to the public could have been avoided by the appropriately staged implementation of new implants. This review comments on the current literature regarding the optimal practice for the introduction of new orthopaedic technology. The authors' experience with the failed ESKA Adapter Short-stem/Modular Hip is described; the methodology used for its evaluation is used as a basis to discuss what was successful about the process and also give warning on what could be improved upon. The ideal practice requires new orthopaedic implants to be evaluated by high-volume surgeons in specialist orthopaedic hospitals. These studies should include biomechanical studies, radiostereophotometric analysis, implant retrieval and outcome assessment. Results and complications should be reported early to the appropriate joint registry and regulatory body. Once a suitable evidence base has developed, the implant can be distributed into wider clinical practice or withdrawn. These recommendations aim to protect the patient and public from harm while allowing surgical innovation to still continue.
Collapse
Affiliation(s)
- Richard Hannan
- Department of Orthopaedics, Royal Hobart Hospital, Hobart, Tasmania, Australia
| | - Varun Arora
- Department of Orthopaedics, Royal Hobart Hospital, Hobart, Tasmania, Australia
| | - Richard Beaver
- Department of Orthopaedics, Royal Perth Hospital, Perth, Western Australia, Australia
| | - Paul Harvie
- Department of Orthopaedics, Royal Hobart Hospital, Hobart, Tasmania, Australia
| |
Collapse
|
126
|
Cottino U, Dettoni F, Risitano S, Marmotti A, Rossi R. Two-Stage Treatment of a Large Pelvic Cystic Pseudotumor in a Metal-On-Metal Total Hip Arthroplasty. JOINTS 2017; 5:121-124. [PMID: 29114642 PMCID: PMC5672869 DOI: 10.1055/s-0037-1603676] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The authors report a case of a huge cystic pseudotumor, surrounding a failed metal-on-metal total hip arthroplasty (THA). The cyst surrounded the hip anteriorly, occupied part of the anterior portion of the thigh, and extended to the anterolateral aspect of the abdomen. The case was treated by a two-stage procedure. The first stage consisted of a percutaneous drainage of the fluid content of the cyst (∼1,200 mL). This procedure reduced the risk of tearing the cyst capsule spreading the liquid in the tissues surrounding the THA, and in the abdomen. Thanks to this simple procedure, the second stage treatment consisted of a relatively usual THA revision. The patient recovered completely from the treatment and returned to pain-free full activities of daily living.
Collapse
Affiliation(s)
- Umberto Cottino
- Department of Orthopaedics and Traumatology, Ospedale Mauriziano Umberto I, Turin, Italy
| | - Federico Dettoni
- Department of Orthopaedics and Traumatology, Ospedale Mauriziano Umberto I, Turin, Italy
| | - Salvatore Risitano
- Department of Orthopaedics and Traumatology, Ospedale Mauriziano Umberto I, Turin, Italy
| | - Antonio Marmotti
- Department of Orthopaedics and Traumatology, Ospedale Mauriziano Umberto I, Turin, Italy
| | - Roberto Rossi
- Department of Orthopaedics and Traumatology, Ospedale Mauriziano Umberto I, Turin, Italy.,Department of Orthopedics and Traumatology, University of Turin, Turin, Italy
| |
Collapse
|
127
|
O'Connor SM, Wobker SE, Cardona DM, Eward W, Esther RJ, Dodd LG. Iatrogenic lesions of soft tissue and bone. Semin Diagn Pathol 2017; 35:208-217. [PMID: 29110897 DOI: 10.1053/j.semdp.2017.09.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- S M O'Connor
- Department of Pathology and Laboratory Medicine, University of North Carolina Chapel Hill, United States
| | - S E Wobker
- Department of Pathology and Laboratory Medicine, University of North Carolina Chapel Hill, United States
| | - D M Cardona
- Department of Pathology, Duke University, Durham, NC, United States
| | - W Eward
- Division of Oncology, Department of Orthopaedic Surgery, Duke University, Durham, NC, United States
| | - R J Esther
- Department of Orthopaedic Surgery, University of North Carolina Chapel Hill, United States
| | - L G Dodd
- Department of Pathology and Laboratory Medicine, University of North Carolina Chapel Hill, United States.
| |
Collapse
|
128
|
Vierra BM, Blumenthal SR, Amanatullah DF. Modularity in Total Hip Arthroplasty: Benefits, Risks, Mechanisms, Diagnosis, and Management. Orthopedics 2017; 40:355-366. [PMID: 28598491 DOI: 10.3928/01477447-20170606-01] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2016] [Accepted: 11/07/2016] [Indexed: 02/03/2023]
Abstract
Modular implants are currently widely used in total hip arthroplasty because they give surgeons versatility during the operation, allow for easier revision surgery, and can be adjusted to better fit the anatomy of the specific patient. However, modular implants, specifically those that have metal-on-metal junctions, are susceptible to crevice and fretting corrosion. This can ultimately cause implant failure, inflammation, and adverse local tissue reaction, among other possible side effects. Surgeons should be aware of the possibility of implant corrosion and should follow a set of recommended guidelines to systematically diagnose and treat patients with corroded implants. Ultimately, surgeons will continue to use modular implants because of their widespread benefits. However, more research is needed to determine how to minimize corrosion and the negative side effects that have been associated with modular junctions in total hip arthroplasty. [Orthopedics. 2017; 40(6):355-366.].
Collapse
|
129
|
Ando W, Yamamoto K, Koyama T, Hashimoto Y, Yasui H, Tsujimoto T, Aihara M, Ohzono K. Chronic Expanding Hematoma After Metal-on-Metal Total Hip Arthroplasty. Orthopedics 2017; 40:e1103-e1106. [PMID: 28662252 DOI: 10.3928/01477447-20170619-04] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2017] [Accepted: 05/10/2017] [Indexed: 02/03/2023]
Abstract
A 76-year-old woman who underwent bilateral metal-on-metal total hip arthroplasty fell 3 years after this procedure and subsequently incurred continuous pain in her buttock. Plain radiographs showed no fracture and no loosening of the hip prosthesis. Magnetic resonance imaging revealed an abnormal, large, thick-walled mass with heterogeneous signal intensity at the right buttock. The prerevision diagnosis was adverse reaction to metal debris. The mass was surgically resected, and the metal femoral head was replaced by a dual-mobility prosthesis. The intraoperative and histological analyses indicated an expanding hematoma. Cobalt ion concentrations of whole blood and effusion around the hematoma-1.9 µg/L and 1.3 µg/L, respectively-were not indicative of adverse reaction to metal debris. Transcatheter arterial embolization was performed 2 days postoperatively. The hematoma was reduced and was not present after 9 months. The diagnosis of a periprosthetic soft tissue mass after metal-on-metal total hip arthroplasty should be carefully reached with magnetic resonance imaging and assessment of blood metal ion concentrations. Expanding hematoma should be considered a potential diagnosis if metal ion concentrations are not increasing and magnetic resonance imaging shows a periprosthetic mass with a heterogeneous lesion. Embolization is useful for the management of an expanding hematoma. [Orthopedics. 2017; 40(6):e1103-e1106.].
Collapse
|
130
|
Vaculova J, Gallo J, Hurnik P, Motyka O, Goodman SB, Dvorackova J. Low intrapatient variability of histomorphological findings in periprosthetic tissues from revised metal/ceramic on polyethylene joint arthroplasties. J Biomed Mater Res B Appl Biomater 2017; 106:2008-2018. [PMID: 29044940 DOI: 10.1002/jbm.b.33990] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2016] [Revised: 07/25/2017] [Accepted: 08/30/2017] [Indexed: 11/05/2022]
Abstract
The type of tissue response to implant by-products can be determined by examination of periprosthetic tissues. However, little is known about the most suitable location for tissue sampling. The main goal of this study was to evaluate the extent of variability in tissue response in relation to location of tissue sampling, implant fixation, age and sex in total joint arthroplasties with metal-on-polyethylene or ceramic-on-polyethylene bearing pairs. We processed 236 histology slides from 21 patients and focused on the association between the location of tissue samples and histological features. The presence of the synovial hyperplasia showed a significant association with the particular sampling site. A higher density of high endothelial cell venules was seen in the samples from around the joint, and polyethylene particles were more abundant in noncemented TJA but both findings did not show statistically significant association with the sampling site. The results showed a relatively small variance in the tissue response to prosthetic by-products among tissues sampled from the same patient. Our findings indicate that tissue samples retrieved from similar distance from around the TJA during the revision operation show comparable results of histological analysis. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2008-2018, 2018.
Collapse
Affiliation(s)
- Jana Vaculova
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Faculty Hospital Olomouc, Olomouc, 775 20, Czech Republic.,Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Faculty Hospital Olomouc, Olomouc, 775 20, Czech Republic
| | - Pavel Hurnik
- Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic.,CBG Laboratory a. s., Ostrava 3, 703 00, Czech Republic
| | - Oldrich Motyka
- Nanotechnology Centre, VŠB - Technical University of Ostrava, Ostrava-Poruba, 708 33, Czech Republic
| | - Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford Medical Center Outpatient Clinic, Redwood City, CA, 94063
| | - Jana Dvorackova
- Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic.,CBG Laboratory a. s., Ostrava 3, 703 00, Czech Republic
| |
Collapse
|
131
|
Pseudotumor in ceramic-on-metal total hip arthroplasty. Arthroplast Today 2017; 3:220-224. [PMID: 29204484 PMCID: PMC5712035 DOI: 10.1016/j.artd.2017.09.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Revised: 09/01/2017] [Accepted: 09/06/2017] [Indexed: 12/27/2022] Open
Abstract
The increasing demand for total hip arthroplasty (THA) in relatively young, high-demand patients has led to the use of hard-on-hard bearing surfaces. Adverse local tissue reaction/pseudotumor and elevated serum metal ion levels are commonly reported complications encountered in metal-on-metal THA, while audible articulation and rim fracture are reported in ceramic-on-ceramic THA. For this reason, ceramic-on-metal THA was implemented as an ideal hard-on-hard bearing combination. In this report, we describe a case of bilateral simultaneous ceramic-on-metal THA in a 69-year-old woman who presented 7 years postoperatively with unilateral hip pain associated with underlying pseudotumor and elevated serum cobalt and chromium ion levels. Pre-revision workup, intraoperative findings, and postoperative evaluation are included and suggest acetabular malposition as a potential source for complication.
Collapse
|
132
|
Mercuri LG, Urban RM, Hall DJ, Mathew MT. Adverse Local Tissue Responses to Failed Temporomandibular Joint Implants. J Oral Maxillofac Surg 2017; 75:2076-2084. [DOI: 10.1016/j.joms.2017.03.044] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Revised: 03/24/2017] [Accepted: 03/24/2017] [Indexed: 11/30/2022]
|
133
|
Matharu GS, Berryman F, Judge A, Reito A, McConnell J, Lainiala O, Young S, Eskelinen A, Pandit HG, Murray DW. Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris: An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants. J Bone Joint Surg Am 2017; 99:1532-1539. [PMID: 28926382 PMCID: PMC5805279 DOI: 10.2106/jbjs.16.01568] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The authors of recent studies have reported newly devised implant-specific blood metal ion thresholds to predict adverse reactions to metal debris (ARMD) in patients who have undergone unilateral or bilateral metal-on-metal (MoM) hip arthroplasty. These thresholds were most effective for identifying patients at low risk of ARMD. We investigated whether these newly devised blood metal ion thresholds could effectively identify patients at risk of ARMD after MoM hip arthroplasty in an external cohort of patients. METHODS We performed a validation study involving 803 MoM hip arthroplasties (323 unilateral Birmingham Hip Resurfacing [BHR], 93 bilateral BHR, and 294 unilateral Corail-Pinnacle implants) performed in 710 patients at 3 European centers. All patients underwent whole-blood metal ion sampling, and were divided into 2 groups: those with ARMD (leading to revision or identified on imaging; n = 75) and those without ARMD (n = 635). Previously devised implant-specific blood metal ion thresholds (2.15 μg/L of cobalt for unilateral BHR; 5.5 μg/L for the maximum of either cobalt or chromium for bilateral BHR; and 3.57 μg/L of cobalt for unilateral Corail-Pinnacle implants) were applied to the validation cohort, and receiver operating characteristic curve analysis was used to establish the discriminatory characteristics of each threshold. RESULTS The area under the curve, sensitivity, specificity, and positive and negative predictive values for the ability of each implant-specific threshold to distinguish between patients with and without ARMD were, respectively, 89.4% (95% confidence interval [CI] = 82.8% to 96.0%), 78.9%, 86.7%, 44.1%, and 96.9% for unilateral BHR; 89.2% (CI = 81.3% to 97.1%), 70.6%, 86.8%, 54.5%, and 93.0% for bilateral BHR; and 76.9% (CI = 63.9% to 90.0%), 65.0%, 85.4%, 24.5%, and 97.1% for unilateral Corail-Pinnacle implants. Using the implant-specific thresholds, we missed 20 patients with ARMD (2.8% of the patients in this series). We missed more patients with ARMD when we used the fixed thresholds proposed by regulatory authorities: 35 (4.9%) when we used the U.K. threshold of 7 μg/L for both cobalt and chromium (p = 0.0003), 21 (3.0%) when we used the U.S. threshold of 3 μg/L for both cobalt and chromium (p = 1.0), and 46 (6.5%) when we used the U.S. threshold of 10 μg/L for both cobalt and chromium (p < 0.0001). CONCLUSIONS This external multicenter validation study confirmed that patients with blood metal ion levels below new implant-specific thresholds have a low risk of ARMD after MoM hip arthroplasty. Using these implant-specific thresholds, we missed fewer patients with ARMD compared with when the thresholds currently proposed by regulatory authorities were used. We therefore recommend using implant-specific blood metal ion thresholds when managing patients who have undergone MoM hip arthroplasty. LEVEL OF EVIDENCE Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Gulraj S. Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
- The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Fiona Berryman
- The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
- MRC Lifecourse Epidemiology Unit, Southampton General Hospital, University of Southampton, Southampton, United Kingdom
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | - Olli Lainiala
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | - Hemant G. Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
- Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), Chapel Allerton Hospital, Leeds, United Kingdom
| | - David W. Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
| |
Collapse
|
134
|
|
135
|
Di Laura A, Quinn PD, Panagiotopoulou VC, Hothi HS, Henckel J, Powell JJ, Berisha F, Amary F, Mosselmans JFW, Skinner JA, Hart AJ. The Chemical Form of Metal Species Released from Corroded Taper Junctions of Hip Implants: Synchrotron Analysis of Patient Tissue. Sci Rep 2017; 7:10952. [PMID: 28887488 PMCID: PMC5591307 DOI: 10.1038/s41598-017-11225-w] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 08/21/2017] [Indexed: 02/08/2023] Open
Abstract
The mechanisms of metal release from the articulation at the head cup bearing and the tapered junctions of orthopaedic hip implants are known to differ and the debris generated varies in size, shape and volume. Significantly less metal is lost from the taper junction between Cobalt-Chromium-Molybdenum (CoCrMo) and Titanium (Ti) components (fretting-corrosion dominant mechanism), when compared to the CoCrMo bearing surfaces (wear-corrosion dominant mechanism). Corrosion particles from the taper junction can lead to Adverse Reactions to Metal Debris (ARMD) similar to those seen with CoCrMo bearings. We used synchrotron methods to understand the modes underlying clinically significant tissue reactions to Co, Cr and Ti by analysing viable peri-prosthetic tissue. Cr was present as Cr2O3 in the corroded group in addition to CrPO4 found in the metal-on-metal (MoM) group. Interestingly, Ti was present as TiO2 in an amorphous rather than rutile or anatase physical form. The metal species were co-localized in the same micron-scale particles as result of corrosion processes and in one cell type, the phagocytes. This work gives new insights into the degradation products from metal devices as well as guidance for toxicological studies in humans.
Collapse
Affiliation(s)
- Anna Di Laura
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.
| | - Paul D Quinn
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, United Kingdom
| | - Vasiliki C Panagiotopoulou
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Harry S Hothi
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Johann Henckel
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Jonathan J Powell
- Biomineral Research Group, Dept Veterinary Medicine, University of Cambridge, Cambridge, United Kingdom
| | - Fitim Berisha
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Fernanda Amary
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - J Fred W Mosselmans
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, United Kingdom
| | - John A Skinner
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| |
Collapse
|
136
|
Liu F, Fisher J. Effect of an edge at cup rim on contact stress during micro-separation in ceramic-on-ceramic hip joints. TRIBOLOGY INTERNATIONAL 2017; 113:323-329. [PMID: 28867870 PMCID: PMC5465945 DOI: 10.1016/j.triboint.2017.01.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 01/09/2017] [Accepted: 01/10/2017] [Indexed: 06/07/2023]
Abstract
Alumina ceramic total hip joint bearings have shown superior wear properties. The joint bearing may undergo adverse conditions such as micro-separation causing head contact on the cup rim. As a transition, an edge is formed between the cup bearing and the rim. The aim of this study was to predict the effect of the edge on contact stresses in order to better understand the mechanisms of wear. A finite element contact model was developed under the conditions of the head displacements 0.5-2 mm and vertical loads 0.5-3 kN. The edge contact produced the most severe stresses capable of causing elevated wear and damage to ceramic bearings. The study shows that the bearing design should be considered in association with clinical conditions to eliminate severe stress.
Collapse
Affiliation(s)
- Feng Liu
- School of Mechanical and Power Engineering, North University of China, PR China
| | - John Fisher
- Institute of Medical and Biological Engineering School of Mechanical Engineering, University of Leeds,UK
| |
Collapse
|
137
|
Surgical Approach May Influence Survival of Large-Diameter Head Metal-on-Metal Total Hip Arthroplasty: A 6- to 10-Year Follow-Up Study. BIOMED RESEARCH INTERNATIONAL 2017; 2017:4209634. [PMID: 28812014 PMCID: PMC5546076 DOI: 10.1155/2017/4209634] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Accepted: 06/21/2017] [Indexed: 11/23/2022]
Abstract
Large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA) has lost popularity because of metal allergy or ALTRs (adverse local tissue reactions) in the past decade. Whether the surgical approach may influence the survival of LDH-MoM-THA has not been reported. From 2006 to 2009, we performed 96 LDH-MoM-THAs on 80 patients using an in situ head-neck assembly technique through a modified Watson-Jones approach. With a mean follow-up of 8.4 years (range, 6.3–10.1 years), the implant survival rate was 100%. All patients were satisfied with the results and the Harris Hip Score improved from 52 points to 98 points. No ALTRs were found, but 17.7% of the 96 hips (17 adverse events) experienced adverse events related to the cup, including 5 cases of outlier cup malposition, 11 cases of inadequate cup seating, and 1 acetabular fracture. The tissue tension that was improved by a muscle-sparing approach might lessen the chance of microseparation or edge-loading that is taken as the major risk for early implant failure. Further investigation of whether these LDH-MoM-THAs would fail or not would require a longer follow-up or even retrieval analysis in the future.
Collapse
|
138
|
Abstract
Osteosynthesis materials or artificial joint replacement make part of clinical routine. In case of complaints mostly mechanical causes or infections are found. Metals like nickel, chromium and cobalt or bone cement components like acrylates and gentamicine may however potentially cause intolerance reactions to implants. Correspondingly, eczema, delayed wound/bone healing, recurrent effusion, pain or implant loosening have been described as manifestation of implant allergy. In contrast to the high incidence of cutaneous metal allergy, allergies associated with implants are rare. Diagnosis of metal implant allergy is based on excluding differential diagnoses – in particular infection – and on a combined approach of allergological diagnostics by patch test and histopathology of periimplant tissue. Risk factors for allergic sensitization to implants or triggering periimplant allergic reactions in the case of preexisting cutaneous metal allergy are unknown. Despite the risk of developing complications being unclear, titanium-based osteosynthesis materials are recommended for metal-allergic patients and the use of metal-metal couplings in arthroplasty is rather not recommended for such patients. If a regular, potentially applicable CoCr-polyethylene articulation is preferred, the patient has to be well informed and has to give his written consent.
Collapse
|
139
|
Matharu GS, Nandra RS, Berryman F, Judge A, Pynsent PB, Dunlop DJ. Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study. Bone Joint J 2017; 99-B:592-600. [PMID: 28455467 PMCID: PMC5413867 DOI: 10.1302/0301-620x.99b5.bjj-2016-1232.r1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Accepted: 12/30/2016] [Indexed: 12/12/2022]
Abstract
Aims To determine ten-year failure rates following 36 mm metal-on-metal
(MoM) Pinnacle total hip arthroplasty (THA), and identify predictors
of failure. Patients and Methods We retrospectively assessed a single-centre cohort of 569 primary
36 mm MoM Pinnacle THAs (all Corail stems) followed up since 2012
according to Medicines and Healthcare Products Regulation Agency
recommendations. All-cause failure rates (all-cause revision, and
non-revised cross-sectional imaging failures) were calculated, with predictors
for failure identified using multivariable Cox regression. Results Failure occurred in 97 hips (17.0%). The ten-year cumulative
failure rate was 27.1% (95% confidence interval (CI) 21.6 to 33.7).
Primary implantation from 2006 onwards (hazard ratio (HR) 4.30;
95% CI 1.82 to 10.1; p = 0.001) and bilateral MoM hip arthroplasty
(HR 1.59; 95% CI 1.03 to 2.46; p = 0.037) predicted failure. The
effect of implantation year on failure varied over time. From four
years onwards following surgery, hips implanted since 2006 had significantly
higher failure rates (eight years 28.3%; 95% CI 23.1 to 34.5) compared
with hips implanted before 2006 (eight years 6.3%; 95% CI 2.4 to
15.8) (HR 15.2; 95% CI 2.11 to 110.4; p = 0.007). Conclusion We observed that 36 mm MoM Pinnacle THAs have an unacceptably
high ten-year failure rate, especially if implanted from 2006 onwards
or in bilateral MoM hip patients. Our findings regarding implantation
year and failure support recent concerns about the device manufacturing
process. We recommend all patients undergoing implantation since
2006 and those with bilateral MoM hips undergo regular investigation,
regardless of symptoms. Cite this article: Bone Joint J 2017;99-B:592–600.
Collapse
Affiliation(s)
| | - R S Nandra
- The Royal Orthopaedic Hospital, Birmingham, B31 2AP, UK
| | - F Berryman
- The Royal Orthopaedic Hospital, Birmingham, B31 2AP, UK
| | - A Judge
- University of Oxford, Oxford, OX3 7LD, UK
| | - P B Pynsent
- School of Clinical and Experimental Medicine, University of Birmingham, B15 2TT, UK
| | - D J Dunlop
- The Royal Orthopaedic Hospital, Birmingham, B31 2AP, UK
| |
Collapse
|
140
|
Koch KM, Koff MF, Bauer TW, Shah PH, Nencka AS, Sivaram Kaushik S, Potter HG. Off-resonance based assessment of metallic wear debris near total hip arthroplasty. Magn Reson Med 2017. [PMID: 28643347 DOI: 10.1002/mrm.26807] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
PURPOSE The presence of metallic debris near total hip arthroplasty can have a significant impact on longitudinal patient management. Methods for magnetic resonance imaging-based quantification of metallic debris near painful total hip replacements are described and applied to cohorts of symptomatic and control subject cases. METHODS A combination of metal artifact reduction, off-resonance mapping, off-resonance background removal, and spatial clustering methods are utilized to quantify off-resonance signatures in cases of suspected metallosis. These methods are applied to a cohort of symptomatic hip arthroplasties composed of cobalt-chromium alloys. Magnetostatic simulations and theoretical principles are used to illuminate the potential sources of the measured off-resonance effects. Reported metrics from histological tissue assays extracted during surgical revision procedures are also correlated with the proposed magnetic resonance imaging-based quantification results. RESULTS The presented methods identified quantifiable metallosis signatures in more than 70% of the symptomatic and none of the control cases. Preliminary correlations of the MR data with direct histological evaluation of retrieved tissue samples indicate that the observed off-resonance effect may be related to tissue necrosis. CONCLUSIONS Magnetostatic simulations, theoretical principles, and preliminary histological trends suggest that disassociated cobalt is the source of the observed off-resonance signature. Magn Reson Med 79:1628-1637, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Kevin M Koch
- Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Matthew F Koff
- Division of Radiology and Imaging, Hospital for Special Surgery, New York, New York, USA
| | - Thomas W Bauer
- Anatomic Pathology and Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | - Parina H Shah
- Division of Radiology and Imaging, Hospital for Special Surgery, New York, New York, USA
| | - Andrew S Nencka
- Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - S Sivaram Kaushik
- MR Applications and Workflow, GE Healthcare, Milwaukee, Wisconsin, USA
| | - Hollis G Potter
- Division of Radiology and Imaging, Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
141
|
Innocenti M, Vieri B, Melani T, Paoli T, Carulli C. Metal hypersensitivity after knee arthroplasty: fact or fiction? ACTA BIO-MEDICA : ATENEI PARMENSIS 2017. [PMID: 28657568 PMCID: PMC6178998 DOI: 10.23750/abm.v88i2-s.6517] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Background and aim of the work: Hypersensitivity to metals in the general population has an incidence of about 15%, and in rising also for the higher number of joint replacements in the last decades. Total Knee Arthroplasty (TKA) represents the most performed orthopaedic procedure during last years, and it seems to be particularly associated with sensitization after surgery. On the other hand, there is a rising amount of patients with painful but well implanted and functioning TKAs: in certain cases, after the exclusion of the most frequent causes of failure, a condition of hypersensitivity may be found, and a revision with anallergic implants is mandatory. The present study is a review of the potential problems related to hypersensitivity in TKA, its possible diagnostic procedures, and the surgical options to date available. Methods: Medical history, patch testing, and other specific laboratory assays are useful to assess a status of metals hypersensitivity before surgery in subjects undergoing a knee replacement, or even after TKA in patients complaining pain in otherwise well implanted and aligned prostheses. However, few groups worlwide deal with such condition, and all proposed diagnostic protocols may be considered still today conjectural. On the other hand, these represent the most updated knowledge of this condition, and may be useful for both the patient and the orthopaedic surgeon. Once assessed a possible or ascertained allergy to metals, several options are available for primary andr revision knee surgery, in order to avoid the risk of hypersensitivity. Results: A review of the recent publications on this topic and an overview of the related aspects has been made to understand a condition to date considered negligible. Conclusions: Hypersensitivity to metals has not to be nowadays considered a “fiction”, but rather a possible preoperative risk or a postoperative cause of failure of TKA. Crucial is the information of patients and the medical history, associated in suspect cases to laboratory testings. Today in the market several knee implants are available and safe for allergic patients undergoing TKA. (www.actabiomedica.it)
Collapse
|
142
|
Innocenti M, Vieri B, Melani T, Paoli T, Carulli C. Metal hypersensitivity after knee arthroplasty: fact or fiction? ACTA BIO-MEDICA : ATENEI PARMENSIS 2017; 88:78-83. [PMID: 28657568 DOI: 10.23750/abm.v88i2 -s.6517] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Accepted: 06/01/2017] [Indexed: 01/23/2023]
Abstract
BACKGROUND AND AIM OF THE WORK Hypersensitivity to metals in the general population has an incidence of about 15%, and in rising also for the higher number of joint replacements in the last decades. Total Knee Arthroplasty (TKA) represents the most performed orthopaedic procedure during last years, and it seems to be particularly associated with sensitization after surgery. On the other hand, there is a rising amount of patients with painful but well implanted and functioning TKAs: in certain cases, after the exclusion of the most frequent causes of failure, a condition of hypersensitivity may be found, and a revision with anallergic implants is mandatory. The present study is a review of the potential problems related to hypersensitivity in TKA, its possible diagnostic procedures, and the surgical options to date available. METHODS Medical history, patch testing, and other specific laboratory assays are useful to assess a status of metals hypersensitivity before surgery in subjects undergoing a knee replacement, or even after TKA in patients complaining pain in otherwise well implanted and aligned prostheses. However, few groups worlwide deal with such condition, and all proposed diagnostic protocols may be considered still today conjectural. On the other hand, these represent the most updated knowledge of this condition, and may be useful for both the patient and the orthopaedic surgeon. Once assessed a possible or ascertained allergy to metals, several options are available for primary andr revision knee surgery, in order to avoid the risk of hypersensitivity. RESULTS A review of the recent publications on this topic and an overview of the related aspects has been made to understand a condition to date considered negligible. CONCLUSIONS Hypersensitivity to metals has not to be nowadays considered a "fiction", but rather a possible preoperative risk or a postoperative cause of failure of TKA. Crucial is the information of patients and the medical history, associated in suspect cases to laboratory testings. Today in the market several knee implants are available and safe for allergic patients undergoing TKA.
Collapse
|
143
|
Development of malignant lymphoma after metal-on-metal hip replacement: a case report and review of the literature. Skeletal Radiol 2017; 46:831-836. [PMID: 28285449 DOI: 10.1007/s00256-017-2612-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2016] [Revised: 02/14/2017] [Accepted: 02/22/2017] [Indexed: 02/02/2023]
Abstract
A number of previous studies have reported a potential risk of malignancy, particularly hematological malignancy, developing in patients receiving a metal-on-metal (MoM) hip replacement. We report a case of malignant lymphoma that arose in a patient who had an MoM hip arthroplasty complicated by development of a pseudotumour. The tumour was a B cell follicular lymphoma that involved lymph nodes and bone. Metal ions are known to have a genotoxic effect on lymphoid cells. Although epidemiological studies have not established that there is an increased risk of lymphoma associated with MoM implants, only a relatively short time period has elapsed since re-introduction of this type of implant and long-term follow-up of patients with MoM implants is indicated.
Collapse
|
144
|
Wawrzynski J, Gil JA, Goodman AD, Waryasz GR. Hypersensitivity to Orthopedic Implants: A Review of the Literature. Rheumatol Ther 2017; 4:45-56. [PMID: 28364382 PMCID: PMC5443731 DOI: 10.1007/s40744-017-0062-6] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Indexed: 12/18/2022] Open
Abstract
Awareness of rare etiologies for implant failure is becoming increasingly important. In addition to the overall increase in joint arthroplasties, revision surgeries are projected to increase dramatically in the coming years, with volume increasing up to seven-fold between 2005 and 2030. The literature regarding the relationship between metal allergy and implant failure is controversial. It has proven difficult to determine whether sensitization is a cause or a consequence of implant failure. Testing patients with functional implants is not a clinically useful approach, as the rate of hypersensitivity is higher in implant recipients than in the general population, regardless of the status of the implant. As a result of the ineffectiveness of preoperative patch testing for predicting adverse outcomes, as well as the high cost of implementing such patch testing as standard procedure, most orthopedists and dermatologists agree that an alternative prosthesis should only be considered for patients with a history of allergy to a metal in the standard implant. In patients with a failed implant requiring revision surgery, hypersensitivity to an implant component should be considered in the differential diagnosis. Because a metal allergy to implant components is currently not commonly considered in the differential for joint failure in the orthopedic literature, there should be improved communication and collaboration between orthopedists and dermatologists when evaluating joint replacement patients with a presentation suggestive of allergy.
Collapse
Affiliation(s)
| | - Joseph A Gil
- Department of Orthopaedic Surgery, Warren Alpert Medical School, Brown University, Providence, RI, USA.
| | - Avi D Goodman
- Department of Orthopaedic Surgery, Warren Alpert Medical School, Brown University, Providence, RI, USA
| | - Gregory R Waryasz
- Department of Orthopaedic Surgery, Warren Alpert Medical School, Brown University, Providence, RI, USA
| |
Collapse
|
145
|
Kumanto M, Paukkeri EL, Nieminen R, Moilanen E. Cobalt(II) Chloride Modifies the Phenotype of Macrophage Activation. Basic Clin Pharmacol Toxicol 2017; 121:98-105. [DOI: 10.1111/bcpt.12773] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Accepted: 02/22/2017] [Indexed: 12/29/2022]
Affiliation(s)
- Mona Kumanto
- The Immunopharmacology Research Group; Faculty of Medicine and Life Sciences; University of Tampere and Tampere University Hospital; Tampere Finland
| | - Erja-Leena Paukkeri
- The Immunopharmacology Research Group; Faculty of Medicine and Life Sciences; University of Tampere and Tampere University Hospital; Tampere Finland
| | - Riina Nieminen
- The Immunopharmacology Research Group; Faculty of Medicine and Life Sciences; University of Tampere and Tampere University Hospital; Tampere Finland
| | - Eeva Moilanen
- The Immunopharmacology Research Group; Faculty of Medicine and Life Sciences; University of Tampere and Tampere University Hospital; Tampere Finland
| |
Collapse
|
146
|
In-situ Generated Tribomaterial in Metal/Metal Contacts: current understanding and future implications for implants. ACTA ACUST UNITED AC 2017; 10:42-50. [PMID: 28808674 DOI: 10.1016/j.biotri.2017.03.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Artificial hip joints operate in aqueous biofluids that are highly reactive towards metallic surfaces. The reactivity at the metal interface is enhanced by mechanical interaction due to friction, which can change the near-surface structure of the metal and surface chemistry. There are now several reports in the literature about the in-situ generation of reaction films and tribo-metallurgical transformations on metal-on-metal hip joints. This paper summarizes current knowledge and provides a mechanistic interpretation of the surface chemical and metallurgical phenomena. Basic concepts of corrosion and wear are illustrated and used to interpret available literature on in-vitro and in-vivo studies of metal-on-metal hip joints. Based on this review, three forms of tribomaterial, characterized by different combinations of oxide films and organic layers, can be determined. It is shown that the generation of these tribofilms can be related to specific electrochemical and mechanical phenomena in the metal interface. It is suggested that the generation of this surface reaction layer constitutes a way to minimize (mechanical) wear of MoM hip implants.
Collapse
|
147
|
Antoniac I, Negrusoiu M, Mardare M, Socoliuc C, Zazgyva A, Niculescu M. Adverse local tissue reaction after 2 revision hip replacements for ceramic liner fracture: A case report. Medicine (Baltimore) 2017; 96:e6687. [PMID: 28489745 PMCID: PMC5428579 DOI: 10.1097/md.0000000000006687] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
INTRODUCTION In younger patients, ceramic-on-ceramic (CoC) bearing surfaces are usually recommended for total hip replacement (THR) because of their low wear rate and longer expected functional life. Although technical advancements have reduced the risk of ceramic bearings fracture, this complication remains a major concern. CASE DESCRIPTION We present the case of a 56-year-old patient undergoing 3 revision hip arthroplasties of the right hip due to ceramic liner fractures. Initial THR (2008) was performed with a CoC bearing, followed by liner fracture due to trauma a year later. The acetabular component and liner were replaced, with a minor incongruence between the old head and new insert. The 2nd ceramic insert fractured 3.5 years later, following minor trauma. Upon revision, the bearing surface was changed to metal-on-polyethylene (MoP). The performed retrieval analysis demonstrated stripe and rim wear, and evidence of adhesive wear. The patient was referred to us a month later, with a fistula on the lateral side of the hip, discharging black, petroleum-like liquid. Radiology showed well-fixed implants, no dislocation and no apparent polyethylene wear. Microbiological assessment of the discharge showed no infection. Intraoperatively massive metallosis was noticed, with stable acetabular and femoral components. The metal femoral head was heavily abraded, with almost 1% volumetric wear. Hematoxylin and eosin stained frozen tissue samples showed muscular and adipose tissue necrosis, while polarized light microscopy highlighted metal, polyethylene, and ceramic particles. CONCLUSION The present case is yet another report showing the adverse outcomes of using MoP bearings for revision after ceramic liner fracture in THR.
Collapse
Affiliation(s)
- Iulian Antoniac
- Biomaterials Group, Materials Science and Engineering Faculty, University Politehnica of Bucharest
| | - Mihai Negrusoiu
- Colentina Clinical Hospital, Clinic of Orthopaedics and Traumatology I, Bucharest
| | - Mihai Mardare
- Victor Babeş University of Medicine and Pharmacy, Timişoara
| | - Claudiu Socoliuc
- Department of Pathology, Colentina Clinical Hospital
- Department of Anatomical Pathology, Faculty of Dental Medicine, Carol Davila University of Medicine and Pharmacy, Bucharest
| | - Ancuţa Zazgyva
- Department of Cell and Molecular Biology, University of Medicine and Pharmacy Tîrgu Mureş, Tîrgu Mureş
| | - Marius Niculescu
- Colentina Clinical Hospital, Clinic of Orthopaedics and Traumatology I, Bucharest
- Department of Orthopaedics and Traumatology, Faculty of Medicine, Titu Maiorescu University, Bucharest, Romania
| |
Collapse
|
148
|
Munemoto M, Grammatopoulos G, Tanaka Y, Gibbons M, Athanasou NA. The pathology of failed McKee-Farrar implants: correlation with modern metal-on-metal-implant failure. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2017; 28:66. [PMID: 28332156 PMCID: PMC5362663 DOI: 10.1007/s10856-017-5882-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 03/08/2017] [Indexed: 06/06/2023]
Abstract
The McKee-Farrar (MF) prosthesis was the first widely used total hip replacement (THR) to employ a metal-on-metal (MoM) articulation. These implants had a high rate of early aseptic loosening but a number achieved good long-term implant survival, stimulating the reintroduction of second and third generation implants of this type. In this study we analysed archival histopathology of periprosthetic tissues in twenty cases of MF aseptic implant failure to determine if there was evidence of an innate and adaptive immune response similar to that seen in modern MoM implants. The presence of macrophages, the extent of necrosis and the ALVAL response were graded semi-quantitatively. Variable but in most cases extensive tissue necrosis was associated with a heavy macrophage response to Cobalt-Chrome (Co-Cr) wear particles in periprosthetic tissues; most cases also contained evidence of a predominantly lymphocyte response which in eight cases was moderate or heavy (Oxford Grade 2/3). Our findings show that inflammatory and necrotic changes to deposition of Co-Cr wear particles are found in periprosthetic tissues of failed MF implants, indicating that there is an innate and adaptive response similar to that noted in second/third generation MoM implants; they also suggest that the pathobiological response to metal wear particles is likely to have contributed to MF implant failure in these cases.
Collapse
Affiliation(s)
- Mitsuru Munemoto
- Nuffield Department Orthopaedics Rheumatology & Musculoskeletal Sciences (NDORMS), University of Oxford, Windmill Road, Oxford, UK
- Dept of Orthopaedic Surgery, Nara medical University, Kashihara-City, 634-8522, Nara, Japan
| | - George Grammatopoulos
- Nuffield Department Orthopaedics Rheumatology & Musculoskeletal Sciences (NDORMS), University of Oxford, Windmill Road, Oxford, UK.
- Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford, OX3 7LD, UK.
| | - Yasuhito Tanaka
- Dept of Orthopaedic Surgery, Nara medical University, Kashihara-City, 634-8522, Nara, Japan
| | - Max Gibbons
- Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford, OX3 7LD, UK
| | | |
Collapse
|
149
|
Baskey SJ, Lehoux EA, Catelas I. Effects of cobalt and chromium ions on lymphocyte migration. J Orthop Res 2017; 35:916-924. [PMID: 27302629 DOI: 10.1002/jor.23336] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Accepted: 06/05/2016] [Indexed: 02/04/2023]
Abstract
A T cell-mediated hypersensitivity reaction has been reported in some patients with CoCrMo-based implants. However, the role of cobalt and chromium ions in this reaction remains unclear. The objective of the present study was to analyze the effects of Co2+ and Cr3+ in culture medium, as well as the effects of culture supernatants of macrophages exposed to Co2+ or Cr3+ , on the migration of lymphocytes. The release of cytokines/chemokines by macrophages exposed to Co2+ and Cr3+ was also analyzed. The migration of murine lymphocytes was quantified using the Boyden chamber assay and flow cytometry, while cytokine/chemokine release by J774A.1 macrophages was measured by ELISA. Results showed an ion concentration-dependent increase in TNF-α and MIP-1α release and a decrease in MCP-1 and RANTES release. Migration analysis showed that the presence of Co2+ (8 ppm) and Cr3+ (100 ppm) in culture medium increased the migration of T lymphocytes, while it had little or no effect on the migration of B lymphocytes, suggesting that Co2+ and Cr3+ can stimulate the migration of T but not B lymphocytes. Levels of T lymphocyte migration in culture medium containing Co2+ or Cr3+ were not statistically different from those in culture supernatants of macrophages exposed to Co2+ or Cr3+ , suggesting that the effects of the ions and chemokines were not additive, possibly because of ion interference with the chemokines and/or their cognate receptors. Overall, results suggest that Co2+ and Cr3+ are capable of stimulating the migration of T (but not B) lymphocytes in the absence of cytokines/chemokines, and could thereby contribute to the accumulation of more T than B lymphocytes in periprosthetic tissues of some patients with CoCrMo-based implants. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:916-924, 2017.
Collapse
Affiliation(s)
- Stephen J Baskey
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5
| | - Eric A Lehoux
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5
| | - Isabelle Catelas
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5.,Department of Surgery, University of Ottawa, The Ottawa Hospital-General Campus, 501 Smyth Road, Ottawa, Ontario, Canada, K1H 8L6.,Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5
| |
Collapse
|
150
|
Adverse tissue reactions after total hip arthroplasty. Ann Diagn Pathol 2017; 27:83-87. [DOI: 10.1016/j.anndiagpath.2016.07.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2016] [Accepted: 07/27/2016] [Indexed: 01/03/2023]
|