151
|
Athavale R, Kokorite I, Dinkel C, Bakker E, Wehrli B, Crespo GA, Brand A. In Situ Ammonium Profiling Using Solid-Contact Ion-Selective Electrodes in Eutrophic Lakes. Anal Chem 2015; 87:11990-7. [DOI: 10.1021/acs.analchem.5b02424] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Rohini Athavale
- Department
of Surface Waters Research and Management Eawag−Swiss Federal Institute of Aquatic Science and Technology, Seestrasse 79, CH-6047 Kastanienbaum, Switzerland
- Institute
of Biogeochemistry and Pollutant Dynamics, ETH Zurich, Universitätsstrasse
16, CH-8092 Zürich, Switzerland
| | - Ilga Kokorite
- Department
of Surface Waters Research and Management Eawag−Swiss Federal Institute of Aquatic Science and Technology, Seestrasse 79, CH-6047 Kastanienbaum, Switzerland
- Faculty
of Geography and Earth Sciences, University of Latvia, Jelgavas iela 1, LV-1004, Riga, Latvia
- Institute
of Biology, University of Latvia, Miera iela 3, LV-2169, Salaspils, Latvia
| | - Christian Dinkel
- Department
of Surface Waters Research and Management Eawag−Swiss Federal Institute of Aquatic Science and Technology, Seestrasse 79, CH-6047 Kastanienbaum, Switzerland
| | - Eric Bakker
- Department
of Inorganic and Analytical Chemistry, University of Geneva, Quai E.-Ansermet
30, 1211 Geneva, Switzerland
| | - Bernhard Wehrli
- Department
of Surface Waters Research and Management Eawag−Swiss Federal Institute of Aquatic Science and Technology, Seestrasse 79, CH-6047 Kastanienbaum, Switzerland
- Institute
of Biogeochemistry and Pollutant Dynamics, ETH Zurich, Universitätsstrasse
16, CH-8092 Zürich, Switzerland
| | - Gastón A. Crespo
- Department
of Inorganic and Analytical Chemistry, University of Geneva, Quai E.-Ansermet
30, 1211 Geneva, Switzerland
| | - Andreas Brand
- Department
of Surface Waters Research and Management Eawag−Swiss Federal Institute of Aquatic Science and Technology, Seestrasse 79, CH-6047 Kastanienbaum, Switzerland
- Institute
of Biogeochemistry and Pollutant Dynamics, ETH Zurich, Universitätsstrasse
16, CH-8092 Zürich, Switzerland
| |
Collapse
|
152
|
Jaworska E, Maksymiuk K, Michalska A. Optimizing Carbon Nanotubes Dispersing Agents from the Point of View of Ion-selective Membrane Based Sensors Performance - Introducing Carboxymethylcellulose as Dispersing Agent for Carbon Nanotubes Based Solid Contacts. ELECTROANAL 2015. [DOI: 10.1002/elan.201500609] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
153
|
Ha W, Song XY, Chen J, Shi YP. A physical entrapment method for the preparation of carbon nanotube reinforced macroporous adsorption resin with enhanced selective extraction performance. NANOSCALE 2015; 7:18619-18627. [PMID: 26490261 DOI: 10.1039/c5nr05454k] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In this paper, we demonstrate a novel carbon nanotube (CNT) reinforced macroporous adsorption resin (MAR) for the first time. The CNTs were dispersed in water via sonication, and then in situ physically entrapped in the pores of MAR by capillary forces and sonication. The resulting CNT reinforced MAR (CNT-MAR) was proved by transmission electron microscopy (TEM) and confocal laser scanning microscopy (CLSM), and subsequently applied to extract a mixture of 8 types, 14 natural products. For comparison, the extraction efficiency of original MAR without CNTs was also evaluated. After extraction, the supernatants were detected via high-performance liquid chromatography (HPLC). The results indicated that the introduction of carbon nanotubes (CNTs) into the pores of MAR can significantly improve the adsorptive selectivity of MAR for natural products. The original MAR without CNTs has almost the same adsorption capacity for selectively extracting 3 types of natural products (phenols, alkaloids and anthraquinones). However, the CNT-MAR only could selectively extract anthraquinones and the adsorption capacity for three anthraquinone natural products is 1.46-1.83 times higher than that of unmodified MAR. In order to achieve the highest extraction efficiency of CNT-MAR for anthraquinone natural products, the main extraction parameters such as the extraction time and the pH value were also optimized. The CNT-MAR demonstrated an excellent ability to extract anthraquinone natural products with high selectivity and adsorption capacity. Due to its low cost, easy preparation and use, and operational characteristics, it shows great potential for selective extraction of natural products.
Collapse
Affiliation(s)
- Wei Ha
- Key Laboratory of Chemistry of Northwestern Plant Resources of CAS and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, P. R. China.
| | | | | | | |
Collapse
|
154
|
Szűcs J, Lindfors T, Bobacka J, Gyurcsányi RE. Ion-selective Electrodes with 3D Nanostructured Conducting Polymer Solid Contact. ELECTROANAL 2015. [DOI: 10.1002/elan.201500465] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
155
|
Lee HJ, Arrigan DWM, Karim MN, Kim H. Amperometric Ion Sensing Approaches at Liquid/Liquid Interfaces for Inorganic, Organic and Biological Ions. ELECTROCHEMICAL STRATEGIES IN DETECTION SCIENCE 2015. [DOI: 10.1039/9781782622529-00296] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Electrochemistry at the interface between two immiscible electrolyte solutions (ITIES) has become an invaluable tool for the selective and sensitive detection of cationic and anionic species, including charged drug molecules and proteins. In addition, neutral molecules can also be detected at the ITIES via enzymatic reactions. This chapter highlights recent developments towards creating a wide spectrum of sensing platforms involving ion transfer across the ITIES. As well as outlining the basic principles needed for performing these sensing applications, the development of ITIES-based detection strategies for inorganic, organic, and biological ions is discussed.
Collapse
Affiliation(s)
- Hye Jin Lee
- Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University 80 Daehakro, Buk-gu Daegu-city 702-701 Republic of Korea
| | - Damien W. M. Arrigan
- Nanochemistry Research Institute, Department of Chemistry, Curtin University GPO Box U1987 Perth, Western Australia 6845 Australia
| | - Md. Nurul Karim
- Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University 80 Daehakro, Buk-gu Daegu-city 702-701 Republic of Korea
| | - Hyerim Kim
- Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University 80 Daehakro, Buk-gu Daegu-city 702-701 Republic of Korea
| |
Collapse
|
156
|
Bakhtiari M, Ghalami-Choobar B. Thermodynamic study of potassium chloride in glycerol–water mixed solvents using electromotive force measurements at (298.2, 303.2 and 310.2)K. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2015.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
157
|
Mahmoud AM, Abd El-Rahman MK, Elghobashy MR, Rezk MR. Carbon nanotubes versus polyaniline nanoparticles; which transducer offers more opportunities for designing a stable solid contact ion-selective electrode. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2015.07.045] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
158
|
Yuan D, Anthis AHC, Ghahraman Afshar M, Pankratova N, Cuartero M, Crespo GA, Bakker E. All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection in environmental samples. Anal Chem 2015; 87:8640-5. [PMID: 26272001 DOI: 10.1021/acs.analchem.5b01941] [Citation(s) in RCA: 87] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
While ion to electron transducing layers for the fabrication of potentiometric membrane electrodes for the detection of cations have been well established, similar progress for the sensing of anions has not yet been realized. We report for this reason on a novel approach for the development of all-solid-state anion selective electrodes using lipophilic multiwalled carbon nanotubes (f-MWCNTs) as the inner ion to electron transducing layer. This material can be solvent cast, as it conveniently dissolves in tetrahydrofuran (THF), an important advantage to develop uniform films without the need for using surfactants that might deteriorate the performance of the electrode. Solid contact sensors for carbonate, nitrate, nitrite, and dihydrogen phosphate are fabricated and characterized, and all exhibit comparable analytical characteristics to the inner liquid electrodes. For example, the carbonate sensor exhibits a Nernstian slope of 27.2 ± 0.8 mV·dec(-1), a LOD = 2.3 μM, a response time of 1 s, a linear range of four logarithmic units, and a medium-term stability of 0.04 mV·h(-1) is obtained in a pH 8.6 buffered solution. Water layer test, reversibility, and selectivity for chloride, nitrate, and hydroxide are also reported. The excellent properties of f-MWCNTs as a transducer are contrasted to the deficient performance of poly(3-octyl-thiophene) (POT) for carbonate detection. This is evidenced both with a significant drift in the potentiometric measures as well as a pronounced sensitivity to light (either sunlight or artificial light). This latter aspect may compromise its potential for environmental in situ measurements (night/day cycles). The concentration of carbonate is determined in a river sample (Arve river, Geneva) and compared to a reference method (automatic titrator with potentiometric pH detection). The results suggest that nanostructured materials such as f-MWCNTs are an attractive platform as a general ion-to-electron transducer for anion-selective electrodes.
Collapse
Affiliation(s)
- Dajing Yuan
- Department of Inorganic and Analytical Chemistry, University of Geneva , Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Alexandre H C Anthis
- Department of Inorganic and Analytical Chemistry, University of Geneva , Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Majid Ghahraman Afshar
- Department of Inorganic and Analytical Chemistry, University of Geneva , Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Nadezda Pankratova
- Department of Inorganic and Analytical Chemistry, University of Geneva , Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Maria Cuartero
- Department of Inorganic and Analytical Chemistry, University of Geneva , Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Gastón A Crespo
- Department of Inorganic and Analytical Chemistry, University of Geneva , Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Eric Bakker
- Department of Inorganic and Analytical Chemistry, University of Geneva , Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| |
Collapse
|
159
|
Cuartero M, Crespo GA, Bakker E. Tandem Electrochemical Desalination–Potentiometric Nitrate Sensing for Seawater Analysis. Anal Chem 2015. [DOI: 10.1021/acs.analchem.5b01973] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Maria Cuartero
- Department
of Inorganic and
Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Gastón A. Crespo
- Department
of Inorganic and
Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Eric Bakker
- Department
of Inorganic and
Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| |
Collapse
|
160
|
|
161
|
Li F, Gan S, Han D, Niu L. Graphene-Based Nanohybrids for Advanced Electrochemical Sensing. ELECTROANAL 2015. [DOI: 10.1002/elan.201500217] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
162
|
Melzer K, Münzer AM, Jaworska E, Maksymiuk K, Michalska A, Scarpa G. Selective ion-sensing with membrane-functionalized electrolyte-gated carbon nanotube field-effect transistors. Analyst 2015; 139:4947-54. [PMID: 25078394 DOI: 10.1039/c4an00714j] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this work the ion-selective response of an electrolyte-gated carbon-nanotube field-effect transistor (CNT-FET) towards K(+), Ca(2+) and Cl(-) in the biologically relevant concentration range from 10(-1) M to 10(-6) M is demonstrated. The ion-selective response is achieved by modifying the gate-electrode of an electrolyte-gated CNT-FET with ion-selective membranes, which are selective towards the respective target analyte ions. The selectivity, assured by the ion-selective poly(vinyl chloride) based membrane, allows the successful application of the herein proposed K(+)-selective CNT-FET to detect changes in the K(+) activity in the μM range even in solutions containing different ionic backgrounds. The sensing mechanism relies on a superposition of both an ion-sensitive response of the CNT-network as well as a change of the effective gate potential present at the semiconducting channel due to a selective and ion activity-dependent response of the membrane towards different types of ions. Moreover, the combination of a CNT-FET as a transducing element gated with an ion-selective coated-wire electrode offers the possibility to miniaturize the already well-established conventional ion-selective electrode setup. This approach represents a valuable strategy for the realization of portable, multi-purpose and low-cost biosensing devices.
Collapse
Affiliation(s)
- K Melzer
- Institute for Nanoelectronics, Technische Universität München, Arcisstraße 21, 80333 München, Germany.
| | | | | | | | | | | |
Collapse
|
163
|
Li J, Yin T, Qin W. An all-solid-state polymeric membrane Pb2+-selective electrode with bimodal pore C60 as solid contact. Anal Chim Acta 2015; 876:49-54. [DOI: 10.1016/j.aca.2015.03.038] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2015] [Accepted: 03/24/2015] [Indexed: 10/23/2022]
|
164
|
Shvedene NV, Rzhevskaia AV, Anuchin NM, Kapitanova OO, Baranov AN, Pletnev IV. Reduced graphene oxide in the construction of solid-state bromide-selective electrode. JOURNAL OF ANALYTICAL CHEMISTRY 2015. [DOI: 10.1134/s1061934815030193] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
165
|
Sun Q, Li W, Su B. Highly hydrophobic solid contact based on graphene-hybrid nanocomposites for all solid state potentiometric sensors with well-formulated phase boundary potentials. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2014.12.038] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
166
|
Hu J, Ho KT, Zou XU, Smyrl WH, Stein A, Bühlmann P. All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices. Anal Chem 2015; 87:2981-7. [DOI: 10.1021/ac504556s] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
- Jinbo Hu
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Kieu T. Ho
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Xu U. Zou
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - William H. Smyrl
- Department
of Chemical Engineering and Materials Science, University of Minnesota, 421 Washington Avenue SE, Minneapolis, Minnesota 55455, United States
| | - Andreas Stein
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
167
|
Woźnica E, Wójcik MM, Wojciechowski M, Mieczkowski J, Bulska E, Maksymiuk K, Michalska A. Improving the Upper Detection Limit of Potentiometric Sensors. ELECTROANAL 2015. [DOI: 10.1002/elan.201400567] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
168
|
Paczosa-Bator B, Pięk M, Piech R. Application of nanostructured TCNQ to potentiometric ion-selective K(+) and Na(+) electrodes. Anal Chem 2015; 87:1718-25. [PMID: 25551547 DOI: 10.1021/ac503521t] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
A new type of potentiometric solid-state ion-selective electrode (SS-ISE) has been fabricated with an intermediate layer made of 7,7,8,8-tetracyanoquinodimethane (TCNQ) or its ion-radical salts and an ionophore-based ion-selective membrane. To show the influence of the TCNQ layer on electrode selectivity, sodium- and potassium-sensitive membranes were applied. A good Nernstian response with a slope of 59.24 mV/dec in the range from 10(-6.5) to 10(-1) M KCl and 58.68 mV/dec (10(-6) to 10(-1) M NaCl) was observed. The influence of an interfacial water film was assessed by an aqueous-layer test performed during potentiometric measurements. The stability of the electrical potential of the new solid-contact electrodes was tested by performing current-reversal chronopotentiometry, and the capacitance of the electrodes is 132 μF or 154 μF for K(+) and Na(+) solid-contact electrodes. These properties confirmed the analytical applicability of TCNQ-based SC-ISEs and should allow the development of a new solid-state ion sensor group.
Collapse
Affiliation(s)
- Beata Paczosa-Bator
- AGH-UST University of Science and Technology , Faculty of Material Science and Ceramics, Mickiewicza 30, PL-30059 Cracow, Poland
| | | | | |
Collapse
|
169
|
A simple approach for fabricating solid-contact ion-selective electrodes using nanomaterials as transducers. Anal Chim Acta 2015; 853:291-296. [DOI: 10.1016/j.aca.2014.10.033] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2014] [Revised: 10/14/2014] [Accepted: 10/24/2014] [Indexed: 11/17/2022]
|
170
|
Ye J, Li F, Gan S, Jiang Y, An Q, Zhang Q, Niu L. Using sp2-C dominant porous carbon sub-micrometer spheres as solid transducers in ion-selective electrodes. Electrochem commun 2015. [DOI: 10.1016/j.elecom.2014.10.014] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
171
|
SONG Y, MA L. A Solid-contact Pb 2+-selective Electrode with Carbon Nanotubes by Electrodeposition as Ion-to-electron Transducer. ELECTROCHEMISTRY 2015. [DOI: 10.5796/electrochemistry.83.402] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Yuehai SONG
- School of Environmental and Materials Engineering, Yantai University
| | - Lijie MA
- School of Environmental and Materials Engineering, Yantai University
| |
Collapse
|
172
|
Sabek J, Adriaenssens L, Guinovart T, Parra EJ, Rius FX, Ballester P, Blondeau P. Chloride-Selective Electrodes Based on “Two-Wall” Aryl-Extended Calix[4]Pyrroles: Combining Hydrogen Bonds and Anion-π Interactions to Achieve Optimum Performance. Chemistry 2014; 21:448-54. [DOI: 10.1002/chem.201403853] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2014] [Indexed: 11/10/2022]
|
173
|
Yin T, Pan D, Qin W. All-Solid-State Polymeric Membrane Ion-Selective Miniaturized Electrodes Based on a Nanoporous Gold Film as Solid Contact. Anal Chem 2014; 86:11038-44. [DOI: 10.1021/ac5029209] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Tanji Yin
- Key
Laboratory of Coastal Environmental Processes and Ecological Remediation
and Shandong Provincial Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences (YICCAS), Yantai, Shandong 264003, P. R. China
- University of the Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Dawei Pan
- Key
Laboratory of Coastal Environmental Processes and Ecological Remediation
and Shandong Provincial Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences (YICCAS), Yantai, Shandong 264003, P. R. China
| | - Wei Qin
- Key
Laboratory of Coastal Environmental Processes and Ecological Remediation
and Shandong Provincial Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences (YICCAS), Yantai, Shandong 264003, P. R. China
| |
Collapse
|
174
|
Gedi V, Kim YP. Detection and characterization of cancer cells and pathogenic bacteria using aptamer-based nano-conjugates. SENSORS (BASEL, SWITZERLAND) 2014; 14:18302-27. [PMID: 25268922 PMCID: PMC4239906 DOI: 10.3390/s141018302] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Revised: 08/08/2014] [Accepted: 09/02/2014] [Indexed: 12/30/2022]
Abstract
Detection and characterization of cells using aptamers and aptamer-conjugated nanoprobes has evolved a great deal over the past few decades. This evolution has been driven by the easy selection of aptamers via in vitro cell-SELEX, permitting sensitive discrimination between target and normal cells, which includes pathogenic prokaryotic and cancerous eukaryotic cells. Additionally, when the aptamer-based strategies are used in conjunction with nanomaterials, there is the potential for cell targeting and therapeutic effects with improved specificity and sensitivity. Here we review recent advances in aptamer-based nano-conjugates and their applications for detecting cancer cells and pathogenic bacteria. The multidisciplinary research utilized in this field will play an increasingly significant role in clinical medicine and drug discovery.
Collapse
Affiliation(s)
- Vinayakumar Gedi
- Department of Life Science, Hanyang University, Seoul 133-791, Korea.
| | - Young-Pil Kim
- Department of Life Science, Hanyang University, Seoul 133-791, Korea.
| |
Collapse
|
175
|
Zou XU, Chen LD, Lai CZ, Bühlmann P. Ionic Liquid Reference Electrodes With a Well-Controlled Co(II)/Co(III) Redox Buffer as Solid Contact. ELECTROANAL 2014. [DOI: 10.1002/elan.201400274] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
176
|
Zou XU, Zhen XV, Cheong JH, Bühlmann P. Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact. Anal Chem 2014; 86:8687-92. [DOI: 10.1021/ac501625z] [Citation(s) in RCA: 72] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Xu U. Zou
- Department of Chemistry, University of Minnesota, 207 Pleasant
Street SE, Minneapolis, Minnesota 55455, United States
| | - Xue V. Zhen
- Department of Chemistry, University of Minnesota, 207 Pleasant
Street SE, Minneapolis, Minnesota 55455, United States
| | - Jia H. Cheong
- Department of Chemistry, University of Minnesota, 207 Pleasant
Street SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant
Street SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
177
|
Mensah ST, Gonzalez Y, Calvo-Marzal P, Chumbimuni-Torres KY. Nanomolar Detection Limits of Cd2+, Ag+, and K+ Using Paper-Strip Ion-Selective Electrodes. Anal Chem 2014; 86:7269-73. [DOI: 10.1021/ac501470p] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Samantha T. Mensah
- Department of Chemistry, University of Central Florida, Orlando, Florida 32816-2366, United States
| | - Yessenia Gonzalez
- Department of Chemistry, University of Central Florida, Orlando, Florida 32816-2366, United States
| | - Percy Calvo-Marzal
- Department of Chemistry, University of Central Florida, Orlando, Florida 32816-2366, United States
| | | |
Collapse
|
178
|
Hu J, Zou XU, Stein A, Bühlmann P. Ion-selective electrodes with colloid-imprinted mesoporous carbon as solid contact. Anal Chem 2014; 86:7111-8. [PMID: 24983327 DOI: 10.1021/ac501633r] [Citation(s) in RCA: 123] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
A new type of solid-contact ion-selective electrode (SC-ISE) has been developed that uses colloid-imprinted mesoporous (CIM) carbon with 24 nm diameter, interconnected mesopores as the intermediate layer between a gold electrode and an ionophore-doped ISE membrane. For a demonstration, valinomycin was used as K(+) ionophore, and a good Nernstian response with a slope of 59.5 mV/decade in the range from 10(-5.2) to 10(-1.0) M was observed. The high purity, low content of redox-active surface functional groups and intrinsic hydrophobic characteristics of CIM carbon prepared from mesophase pitch lead to outstanding performance of these sensors, with excellent resistance to the formation of a water layer and no interference caused by light, O2, and CO2. When a redox couple is introduced as an internal reference species, calibration-free SC-ISEs can be made with a standard deviation of E° as low as 0.7 mV. Moreover, the interconnected mesopore structure of ISE membrane-infused CIM carbon facilitates both ion and electron conduction and provides a large interfacial area with good ion-to-electron transduction. Because of the large double layer capacitance of CIM carbon, CIM carbon-based SC-ISEs exhibit excellent potential stability, as shown by chronopotentiometry and continuous potentiometric measurements. The capacitance of these electrodes as determined by chronopotentiometry is 1.0 mF, and the emf drift over 70 h is as low as 1.3 μV/h, making these electrodes the most stable SC-ISEs reported so far.
Collapse
Affiliation(s)
- Jinbo Hu
- Department of Chemistry, University of Minnesota , 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | | | | | | |
Collapse
|
179
|
Soleimani M, Afshar MG. Octaethylporphyrin as an ionophore for aluminum potentiometric sensor based on carbon paste electrode. RUSS J ELECTROCHEM+ 2014. [DOI: 10.1134/s1023193514060081] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
180
|
Jarolímová Z, Crespo GA, Xie X, Ghahraman Afshar M, Pawlak M, Bakker E. Chronopotentiometric Carbonate Detection with All-Solid-State Ionophore-Based Electrodes. Anal Chem 2014; 86:6307-14. [DOI: 10.1021/ac5004163] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Zdeňka Jarolímová
- Department of Inorganic and
Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Gastón A. Crespo
- Department of Inorganic and
Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Xiaojiang Xie
- Department of Inorganic and
Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Majid Ghahraman Afshar
- Department of Inorganic and
Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Marcin Pawlak
- Department of Inorganic and
Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Eric Bakker
- Department of Inorganic and
Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| |
Collapse
|
181
|
Ambrosi A, Chua CK, Bonanni A, Pumera M. Electrochemistry of Graphene and Related Materials. Chem Rev 2014; 114:7150-88. [DOI: 10.1021/cr500023c] [Citation(s) in RCA: 826] [Impact Index Per Article: 82.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Adriano Ambrosi
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore
| | - Chun Kiang Chua
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore
| | - Alessandra Bonanni
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore
| | - Martin Pumera
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore
| |
Collapse
|
182
|
Miller PR, Xiao X, Brener I, Burckel DB, Narayan R, Polsky R. Microneedle-based transdermal sensor for on-chip potentiometric determination of K(+). Adv Healthc Mater 2014; 3:876-81. [PMID: 24376147 DOI: 10.1002/adhm.201300541] [Citation(s) in RCA: 94] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2013] [Revised: 10/30/2013] [Indexed: 11/07/2022]
Abstract
The determination of electrolytes is invaluable for point of care diagnostic applications. An ion selective transdermal microneedle sensor is demonstrated for potassium by integrating a hollow microneedle with a microfluidic chip to extract fluid through a channel towards a downstream solid-state ion-selective-electrode (ISE). 3D porous carbon and 3D porous graphene electrodes, made via interference lithography, are compared as solid-state transducers for ISE's and evaluated for electrochemical performance, stability, and selectivity. The porous carbon K(+) ISE's show better performance than the porous graphene K(+) ISE's, capable of measuring potassium across normal physiological concentrations in the presence of interfering ions with greater stability. This new microfluidic/microneedle platform shows promise for medical applications.
Collapse
Affiliation(s)
- Philip R. Miller
- Sandia National Laboratories; Albuquerque New Mexico 87185 USA
- Joint Department of Biomedical Engineering; University of North Carolina and North Carolina State University; Raleigh NC 27695-7115 USA
| | - Xiaoyin Xiao
- Sandia National Laboratories; Albuquerque New Mexico 87185 USA
| | - Igal Brener
- Sandia National Laboratories; Albuquerque New Mexico 87185 USA
| | | | - Roger Narayan
- Joint Department of Biomedical Engineering; University of North Carolina and North Carolina State University; Raleigh NC 27695-7115 USA
| | - Ronen Polsky
- Sandia National Laboratories; Albuquerque New Mexico 87185 USA
| |
Collapse
|
183
|
Cuartero M, del Río JS, Blondeau P, Ortuño JA, Rius FX, Andrade FJ. Rubber-based substrates modified with carbon nanotubes inks to build flexible electrochemical sensors. Anal Chim Acta 2014; 827:95-102. [PMID: 24833000 DOI: 10.1016/j.aca.2014.04.022] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 03/03/2014] [Accepted: 04/10/2014] [Indexed: 10/25/2022]
Abstract
The development of a solid-contact potentiometric sensor based on conducting rubbers using a carbon nanotubes ink is described here. Commercial rubbers are turned into conductive ones by a simple and versatile method, i.e. painting an aqueous dispersion of single-walled carbon nanotubes on the polymer surface. On this substrate, both the working ion-selective electrode and the reference electrode are built in order to form an integrated potentiometric cell. As a proof-of-principle, selective potassium electrodes are fully characterized giving comparable performances to conventional electrodes (sensitivity, selectivity, stability, linear range, limit of detection and reproducibility). As an application of the rubber-based electrodes, a bracelet was constructed to measure potassium levels in artificial sweat. Since rubbers are ubiquitous in our quotidian life, this approach offers great promise for the generation of chemical information through daily objects.
Collapse
Affiliation(s)
- María Cuartero
- Department of Analytical Chemistry, Faculty of Chemistry, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, Murcia E-30100, Spain
| | - Jonathan Sabaté del Río
- Department of Analytical and Organic Chemistry, Universitat Rovira i Virgil, Campus Sescelades, Marcel·lí Domingo s/n, Tarragona 43007, Spain
| | - Pascal Blondeau
- Department of Analytical and Organic Chemistry, Universitat Rovira i Virgil, Campus Sescelades, Marcel·lí Domingo s/n, Tarragona 43007, Spain
| | - Joaquín A Ortuño
- Department of Analytical Chemistry, Faculty of Chemistry, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, Murcia E-30100, Spain
| | - F Xavier Rius
- Department of Analytical and Organic Chemistry, Universitat Rovira i Virgil, Campus Sescelades, Marcel·lí Domingo s/n, Tarragona 43007, Spain
| | - Francisco J Andrade
- Department of Analytical and Organic Chemistry, Universitat Rovira i Virgil, Campus Sescelades, Marcel·lí Domingo s/n, Tarragona 43007, Spain.
| |
Collapse
|
184
|
Novell M, Guinovart T, Blondeau P, Rius FX, Andrade FJ. A paper-based potentiometric cell for decentralized monitoring of Li levels in whole blood. LAB ON A CHIP 2014; 14:1308-1314. [PMID: 24513977 DOI: 10.1039/c3lc51098k] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A novel approach to monitor Li levels in blood in decentralized (out of the lab) settings is presented. The approach uses a potentiometric cell fully made with filter paper as a support. Electrodes were built using carbon nanotubes ink to create a conductive path and a suitable polymeric membrane. Solid-state ion-selective electrodes for Li and a reference electrode were built and optimized. The results obtained on real samples of serum and whole blood are comparable with those obtained by conventional standard approaches. This platform shows an outstanding performance for the direct, fast and low-cost monitoring of Li levels in blood.
Collapse
Affiliation(s)
- Marta Novell
- Departament de Química Analítica i Química Orgànica, Universitat Rovira i Virgili, Carrer Marcel.lí Domingo s/n, 43007 Tarragona, Spain.
| | | | | | | | | |
Collapse
|
185
|
Wardak C. Solid Contact Nitrate Ion-Selective Electrode Based on Ionic Liquid with Stable and Reproducible Potential. ELECTROANAL 2014. [DOI: 10.1002/elan.201300590] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
186
|
Paczosa-Bator B. Effects of type of nanosized carbon black on the performance of an all-solid-state potentiometric electrode for nitrate. Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1216-7] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
187
|
Electrochemical control of the standard potential of solid-contact ion-selective electrodes having a conducting polymer as ion-to-electron transducer. Electrochim Acta 2014. [DOI: 10.1016/j.electacta.2013.10.134] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
188
|
Guinovart T, Crespo GA, Rius FX, Andrade FJ. A reference electrode based on polyvinyl butyral (PVB) polymer for decentralized chemical measurements. Anal Chim Acta 2014; 821:72-80. [PMID: 24703216 DOI: 10.1016/j.aca.2014.02.028] [Citation(s) in RCA: 81] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2013] [Revised: 02/14/2014] [Accepted: 02/18/2014] [Indexed: 10/25/2022]
Abstract
A new solid-state reference electrode using a polymeric membrane of polyvinyl butyral (PVB), Ag/AgCl and NaCl to be used in decentralized chemical measurements is presented. The electrode is made by drop-casting the membrane cocktail onto a glassy carbon (GC) substrate. A stable potential (less than 1 mV dec(-1)) over a wide range of concentrations for the several chemical species tested is obtained. No significant influence to changes in redox potential, light and pH are observed. The response of this novel electrode shows good correlation when compared with a conventional double-junction reference electrode. Also good long-term stability (90±33 μV/h) and a lifetime of approximately 4 months are obtained. Aspects related to the working mechanisms are discussed. Atomic Force Microscopy (AFM) studies reveal the presence of nanopores and channels on the surface, and electrochemical impedance spectroscopy (EIS) of optimized electrodes show low bulk resistances, usually in the kΩ range, suggesting that a nanoporous polymeric structure is formed in the interface with the solution. Future applications of this electrode as a disposable device for decentralized measurements are discussed. Examples of the utilization on wearable substrates (tattoos, fabrics, etc) are provided.
Collapse
Affiliation(s)
- Tomàs Guinovart
- Departament de Química Orgànica i Química Analítica, Universitat Rovira i Virgili, Carrer Marcel·lí Domingo s/n 43007 Tarragona, Spain
| | - Gastón A Crespo
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - F Xavier Rius
- Departament de Química Orgànica i Química Analítica, Universitat Rovira i Virgili, Carrer Marcel·lí Domingo s/n 43007 Tarragona, Spain
| | - Francisco J Andrade
- Departament de Química Orgànica i Química Analítica, Universitat Rovira i Virgili, Carrer Marcel·lí Domingo s/n 43007 Tarragona, Spain.
| |
Collapse
|
189
|
Jaworska E, Lewandowski W, Mieczkowski J, Maksymiuk K, Michalska A. Simple and disposable potentiometric sensors based on graphene or multi-walled carbon nanotubes--carbon-plastic potentiometric sensors. Analyst 2014; 138:2363-71. [PMID: 23457707 DOI: 10.1039/c3an36741j] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A simple procedure leading to disposable potentiometric sensors using as a supporting electrode - electrical lead and transducer - a layer of carbon nanostructured material, either graphene or multi-walled nanotubes, is proposed, and the effect of the material used on the properties of the sensor is discussed. The obtained layers were partially covered with a conventional poly(vinyl chloride) (PVC) based ion-selective membrane to result in simple, planar, and disposable potentiometric sensors. The analytical performance of the thus obtained electrodes was compared with that of classical macroscopic all-solid-state ion-selective electrodes (e.g. employing poly(octylthiophene) as a solid contact and a similar ion-selective membrane). It was superior (taking into account detection limits or selectivity towards Na(+) ions) compared to that of other disposable sensors proposed recently. The observed excellent analytical performance was attributed to the applied method of preparation of carbon nanostructured materials, which does not require addition of a surfactant to obtain a stable suspension (ink) used to prepare the electrical lead and the transducer of the sensor. Although the proposed sensors are predominantly intended for disposable use, pronounced stability of potential readings was obtained in within-day experiments. Moreover, due to their high conductivity carbon-plastic electrodes can be also applied in polarized potentiometric measurements.
Collapse
Affiliation(s)
- Ewa Jaworska
- Department of Chemistry, Warsaw University, Pasteura 1, 02-093 Warsaw, Poland
| | | | | | | | | |
Collapse
|
190
|
Agrahari SK, Kumar SD, Srivastava AK. Ion selective electrode for uranium based on composite multiwalled carbon nanotube-benzo-15-crown-5 in PVC matrix coated on graphite rod. JOURNAL OF ANALYTICAL CHEMISTRY 2013. [DOI: 10.1134/s106193481401002x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
191
|
Toczyłowska-Mamińska R, Lewenstam A, Dołowy K. Multielectrode bisensor system for time-resolved monitoring of ion transport across an epithelial cell layer. Anal Chem 2013; 86:390-4. [PMID: 24283934 DOI: 10.1021/ac403808f] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
An ion-selective multielectrode bisensor system is designed to ensure reliable real-time concentration measurements of sodium, potassium, chloride, and pH in a small volume of biological liquid bathing a living human bronchial epithelial cell monolayer. The bisensor system allows the monitoring of major ions, which are simultaneously transported through the epithelia in both directions.
Collapse
Affiliation(s)
- Renata Toczyłowska-Mamińska
- Department of Biophysics, Warsaw University of Life Sciences - SGGW , Nowoursynowska 159, 02-776 Warszawa, Poland
| | | | | |
Collapse
|
192
|
Jarolímová Z, Crespo GA, Afshar MG, Pawlak M, Bakker E. All solid state chronopotentiometric ion-selective electrodes based on ferrocene functionalized PVC. J Electroanal Chem (Lausanne) 2013. [DOI: 10.1016/j.jelechem.2013.10.011] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
193
|
|
194
|
Paczosa-Bator B, Cabaj L, Piech R, Skupień K. Potentiometric Sensors with Carbon Black Supporting Platinum Nanoparticles. Anal Chem 2013; 85:10255-61. [DOI: 10.1021/ac402885y] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Beata Paczosa-Bator
- AGH-UST University of Science and Technology, Faculty
of Material Science and Ceramics, Mickiewicza 30, PL-30059 Cracow, Poland
| | - Leszek Cabaj
- AGH-UST University of Science and Technology, Faculty
of Material Science and Ceramics, Mickiewicza 30, PL-30059 Cracow, Poland
| | - Robert Piech
- AGH-UST University of Science and Technology, Faculty
of Material Science and Ceramics, Mickiewicza 30, PL-30059 Cracow, Poland
| | | |
Collapse
|
195
|
Veder JP, De Marco R, Patel K, Si P, Grygolowicz-Pawlak E, James M, Alam MT, Sohail M, Lee J, Pretsch E, Bakker E. Evidence for a surface confined ion-to-electron transduction reaction in solid-contact ion-selective electrodes based on poly(3-octylthiophene). Anal Chem 2013; 85:10495-502. [PMID: 24080025 DOI: 10.1021/ac4024999] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The ion-to-electron transduction reaction mechanism at the buried interface of the electrosynthesized poly(3-octylthiophene) (POT) solid-contact (SC) ion-selective electrode (ISE) polymeric membrane has been studied using synchrotron radiation-X-ray photoelectron spectroscopy (SR-XPS), near edge X-ray absorption fine structure (NEXAFS), and electrochemical impedance spectroscopy (EIS)/neutron reflectometry (NR). The tetrakis[3,5-bis(triflouromethyl)phenyl]borate (TFPB(-)) membrane dopant in the polymer ISE was transferred from the polymeric membrane to the outer surface layer of the SC on oxidation of POT but did not migrate further into the oxidized POT SC. The TFPB(-) and oxidized POT species could only be detected at the outer surface layer (≤14 Ǻ) of the SC material, even after oxidation of the electropolymerized POT SC for an hour at high anodic potential demonstrating that the ion-to-electron transduction reaction is a surface confined process. Accordingly, this study provides the first direct structural evidence of ion-to-electron transduction in the electropolymerized POT SC ISE by proving TFPB(-) transport from the polymeric ISE membrane to the oxidized POT SC at the buried interface of the SC ISE. It is inferred that the performance of the POT SC ISE is independent of the thickness of the POT SC but is instead contingent on the POT SC surface reactivity and/or electrical capacitance of the POT SC. In particular, the results suggest that the electropolymerized POT conducting polymer may spontaneously form a mixed surface/bulk oxidation state, which may explain the unusually high potential stability of the resulting ISE. It is anticipated that this new understanding of ion-to-electron transduction with electropolymerized POT SC ISEs will enable the development of new and improved devices with enhanced analytical performance attributes.
Collapse
Affiliation(s)
- Jean-Pierre Veder
- Department of Chemistry, Curtin University , GPO Box U1987, Perth, Western Australia 6109, Australia
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
196
|
Zou XU, Cheong JH, Taitt BJ, Bühlmann P. Solid contact ion-selective electrodes with a well-controlled Co(II)/Co(III) redox buffer layer. Anal Chem 2013; 85:9350-5. [PMID: 24047234 DOI: 10.1021/ac4022117] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Solid contact ion-selective electrodes (ISEs) typically have an intermediate layer between the ion-selective membrane and the underlying solid electron conductor that is designed to reduce the irreproducibility and instability of the measured electromotive force (emf). Nevertheless, the electrode-to-electrode reproducibility of the emf of current solid contact ISEs is widely considered to be unsatisfactory. To address this problem, we report here a new method of constructing this intermediate layer based on the lipophilic redox buffer consisting of the Co(III) and Co(II) complexes of 1,10-phenanthroline ([Co(phen)3](3+/2+)) paired with tetrakis(pentafluorophenyl)borate as counterion. The resulting electrodes exhibit emf values with an electrode-to-electrode standard deviation as low as 1.7 mV after conditioning of freshly prepared electrodes for 1 h. While many prior examples of solid contact ISEs also used intermediate layers that contained redox active species, the selection of a balanced ratio of the reduced and oxidized species has typically been difficult and was often ignored, contributing to the emf irreproducibility. The ease of the control of the [Co(phen)3](3+)/[Co(phen)3](2+) ratio explains the high emf reproducibility, as confirmed by the emf decrease of 58 mV per 10-fold increase in the ratio of the reduced and oxidized redox buffer species. Use of a gold electrode modified with a self-assembled 1-hexanethiol monolayer as underlying electron conductor suppresses the formation of a water layer and results in an electrode-to-electrode standard deviation of E° of 1.0 mV after 2 weeks of exposure to KCl solution.
Collapse
Affiliation(s)
- Xu U Zou
- Department of Chemistry, University of Minnesota , 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | | | | | | |
Collapse
|
197
|
Zelada-Guillén GA, Blondeau P, Rius FX, Riu J. Carbon nanotube-based aptasensors for the rapid and ultrasensitive detection of bacteria. Methods 2013; 63:233-8. [PMID: 23872060 DOI: 10.1016/j.ymeth.2013.07.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Revised: 05/08/2013] [Accepted: 07/02/2013] [Indexed: 11/15/2022] Open
Abstract
In this paper we present a new generation of potentiometric biosensors based on carbon nanotubes (transducer layer of the biosensor) and aptamers (sensing layer of the biosensor) for the ultralow and selective detection of microorganisms. We show that with these aptasensors we were able to detect a few CFU of the target bacteria almost in real-time, both in buffered and in real samples.
Collapse
Affiliation(s)
- Gustavo A Zelada-Guillén
- Universitat Rovira i Virgili, Department of Analytical and Organic Chemistry, C/ Marcel·lí Domingo s/n, 43007 Tarragona, Catalonia, Spain
| | | | | | | |
Collapse
|
198
|
Chen LD, Lai CZ, Granda LP, Fierke MA, Mandal D, Stein A, Gladysz JA, Bühlmann P. Fluorous Membrane Ion-Selective Electrodes for Perfluorinated Surfactants: Trace-Level Detection and in Situ Monitoring of Adsorption. Anal Chem 2013; 85:7471-7. [DOI: 10.1021/ac401424j] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Li D. Chen
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis
Minnesota 55455, United States
| | - Chun-Ze Lai
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis
Minnesota 55455, United States
| | - Laura P. Granda
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis
Minnesota 55455, United States
| | - Melissa A. Fierke
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis
Minnesota 55455, United States
| | - Debaprasad Mandal
- Department of Chemistry, Texas A&M University, P.O. Box 30012, College Station, Texas 77842, United States
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis
Minnesota 55455, United States
| | - John A. Gladysz
- Department of Chemistry, Texas A&M University, P.O. Box 30012, College Station, Texas 77842, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis
Minnesota 55455, United States
| |
Collapse
|
199
|
Guinovart T, Parrilla M, Crespo GA, Rius FX, Andrade FJ. Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes. Analyst 2013; 138:5208-15. [PMID: 23775189 DOI: 10.1039/c3an00710c] [Citation(s) in RCA: 95] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A simple and generalized approach to build electrochemical sensors for wearable devices is presented. Commercial cotton yarns are first turned into electrical conductors through a simple dyeing process using a carbon nanotube ink. These conductive yarns are then partially coated with a suitable polymeric membrane to build ion-selective electrodes. Potentiometric measurements using these yarn-potentiometric sensors are demonstrated. Examples of yarns that can sense pH, K(+) and NH4(+) are presented. In all cases, these sensing yarns show limits of detection and linear ranges that are similar to those obtained with lab-made solid-state ion-selective electrodes. Through the immobilization of these sensors in a band-aid, it is shown that this approach could be easily implemented in a wearable device. Factors affecting the performance of the sensors and future potential applications are discussed.
Collapse
Affiliation(s)
- Tomàs Guinovart
- Departamento de Química Orgánica y Química Analítica, Universitat Rovira i Virgili, Carrer Marcel-li Domingo s/n, 43007 Tarragona, Spain
| | | | | | | | | |
Collapse
|
200
|
Soleimani M, Afshar MG, Shafaat A, Crespo GA. High-Selective Tramadol Sensor Based on Modified Molecularly Imprinted PolymerCarbon Paste Electrode with Multiwalled Carbon Nanotubes. ELECTROANAL 2013. [DOI: 10.1002/elan.201200601] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|