201
|
Kalenius E, Groessl M, Rissanen K. Ion mobility–mass spectrometry of supramolecular complexes and assemblies. Nat Rev Chem 2018. [DOI: 10.1038/s41570-018-0062-2] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
202
|
Meier F, Brunner AD, Koch S, Koch H, Lubeck M, Krause M, Goedecke N, Decker J, Kosinski T, Park MA, Bache N, Hoerning O, Cox J, Räther O, Mann M. Online Parallel Accumulation-Serial Fragmentation (PASEF) with a Novel Trapped Ion Mobility Mass Spectrometer. Mol Cell Proteomics 2018; 17:2534-2545. [PMID: 30385480 PMCID: PMC6283298 DOI: 10.1074/mcp.tir118.000900] [Citation(s) in RCA: 552] [Impact Index Per Article: 92.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 10/30/2018] [Indexed: 11/06/2022] Open
Abstract
In bottom-up proteomics, peptides are separated by liquid chromatography with elution peak widths in the range of seconds, whereas mass spectra are acquired in about 100 microseconds with time-of-flight (TOF) instruments. This allows adding ion mobility as a third dimension of separation. Among several formats, trapped ion mobility spectrometry (TIMS) is attractive because of its small size, low voltage requirements and high efficiency of ion utilization. We have recently demonstrated a scan mode termed parallel accumulation - serial fragmentation (PASEF), which multiplies the sequencing speed without any loss in sensitivity (Meier et al., PMID: 26538118). Here we introduce the timsTOF Pro instrument, which optimally implements online PASEF. It features an orthogonal ion path into the ion mobility device, limiting the amount of debris entering the instrument and making it very robust in daily operation. We investigate different precursor selection schemes for shotgun proteomics to optimally allocate in excess of 100 fragmentation events per second. More than 600,000 fragmentation spectra in standard 120 min LC runs are achievable, which can be used for near exhaustive precursor selection in complex mixtures or accumulating the signal of weak precursors. In 120 min single runs of HeLa digest, MaxQuant identified more than 6,000 proteins without matching to a library and with high quantitative reproducibility (R > 0.97). Online PASEF achieves a remarkable sensitivity with more than 2,500 proteins identified in 30 min runs of only 10 ng HeLa digest. We also show that highly reproducible collisional cross sections can be acquired on a large scale (R > 0.99). PASEF on the timsTOF Pro is a valuable addition to the technological toolbox in proteomics, with a number of unique operating modes that are only beginning to be explored.
Collapse
Affiliation(s)
- Florian Meier
- Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Am Klopferspitz 18, 82152 Martinsried, Germany
| | - Andreas-David Brunner
- Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Am Klopferspitz 18, 82152 Martinsried, Germany
| | - Scarlet Koch
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Heiner Koch
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Markus Lubeck
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Michael Krause
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Niels Goedecke
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Jens Decker
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Thomas Kosinski
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Melvin A Park
- Bruker Daltonics Inc., Manning Road, Billerica, Massachusetts 01821
| | - Nicolai Bache
- Evosep Biosystems, Thriges Pl. 6, 5000 Odense, Denmark
| | - Ole Hoerning
- Evosep Biosystems, Thriges Pl. 6, 5000 Odense, Denmark
| | - Jürgen Cox
- Computational Systems Biochemistry, Max Planck Institute of Biochemistry, Am Klopferspitz 18, 82152 Martinsried, Germany
| | - Oliver Räther
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Matthias Mann
- Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Am Klopferspitz 18, 82152 Martinsried, Germany; NNF Center for Protein Research, Faculty of Health Sciences, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark.
| |
Collapse
|
203
|
Hollerbach A, Fedick PW, Cooks RG. Ion Mobility–Mass Spectrometry Using a Dual-Gated 3D Printed Ion Mobility Spectrometer. Anal Chem 2018; 90:13265-13272. [PMID: 30281279 DOI: 10.1021/acs.analchem.8b02209] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Adam Hollerbach
- Chemistry Department, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | - Patrick W. Fedick
- Chemistry Department, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | - R. Graham Cooks
- Chemistry Department, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| |
Collapse
|
204
|
Hinnenkamp V, Klein J, Meckelmann SW, Balsaa P, Schmidt TC, Schmitz OJ. Comparison of CCS Values Determined by Traveling Wave Ion Mobility Mass Spectrometry and Drift Tube Ion Mobility Mass Spectrometry. Anal Chem 2018; 90:12042-12050. [DOI: 10.1021/acs.analchem.8b02711] [Citation(s) in RCA: 56] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Vanessa Hinnenkamp
- IWW Water Centre, Moritzstraße 26, 45476 Muelheim an der Ruhr, Germany
- Instrumental Analytical Chemistry and Centre for Water and Environmental Research, Universitaetsstrasse 5, 45141 Essen, Germany
| | | | | | - Peter Balsaa
- IWW Water Centre, Moritzstraße 26, 45476 Muelheim an der Ruhr, Germany
| | - Torsten C. Schmidt
- IWW Water Centre, Moritzstraße 26, 45476 Muelheim an der Ruhr, Germany
- Instrumental Analytical Chemistry and Centre for Water and Environmental Research, Universitaetsstrasse 5, 45141 Essen, Germany
| | | |
Collapse
|
205
|
Gomez JD, Ridgeway ME, Park MA, Fritz KS. Utilizing Ion Mobility to Identify Isobaric Post-Translational Modifications: Resolving Acrolein and Propionyl Lysine Adducts by TIMS Mass Spectrometry. INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY : OFFICIAL PUBLICATION OF THE INTERNATIONAL SOCIETY FOR ION MOBILITY SPECTROMETRY 2018; 21:65-69. [PMID: 30369833 PMCID: PMC6200409 DOI: 10.1007/s12127-018-0237-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Accepted: 07/30/2018] [Indexed: 01/07/2023]
Abstract
Protein post-translational modifications provide critical proteomic details towards elucidating mechanisms of altered protein function due to toxic exposure, altered metabolism, or disease pathogenesis. Lysine propionylation is a recently described modification that occurs due to metabolic alterations in propionyl-CoA metabolism and sirtuin depropionylase activity. Acrolein is a toxic aldehyde generated through exogenous and endogenous pathways, such as industrial exposure, cigarette smoke inhalation, and non-enzymatic lipid peroxidation. Importantly, lysine modifications arising from propionylation and acroleination can be isobaric - indistinguishable by mass spectrometry - and inseparable via reverse-phase chromatography. Here, we present the novel application of trapped ion mobility spectrometry (TIMS) to resolve such competing isobaric lysine modifications. Specifically, the PTM products of a small synthetic peptide were analyzed using a prototype TIMS - time-of-flight mass spectrometer (TIMS-TOF). In that the mobilities of these propionylated and acroleinated peptides differ by only 1%, a high-resolution mobility analysis is required to resolve the two. We were able to achieve more than sufficient resolution in the TIMS analyzer (~170), readily separating these isobars.
Collapse
Affiliation(s)
- Jose D. Gomez
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, United States
| | | | | | - Kristofer S. Fritz
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, United States
| |
Collapse
|
206
|
Keating JE, Glish GL. Dual Emitter Nano-Electrospray Ionization Coupled to Differential Ion Mobility Spectrometry-Mass Spectrometry for Shotgun Lipidomics. Anal Chem 2018; 90:9117-9124. [PMID: 29989393 DOI: 10.1021/acs.analchem.8b01528] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Current lipidomics workflows are centered around acquisition of large data sets followed by lengthy data processing. A dual nESI-DIMS-MS platform was developed to perform real-time relative quantification between samples, providing data required for biomarker discovery and validation more quickly than traditional ESI-MS approaches. Nanosprayer activity and DIMS compensation field settings were controlled by a LabVIEW program synced to the accumulation portion of the ion trap scan function, allowing for full integration of the platform with a commercial mass spectrometer. By comparing samples with short electrospray pulses rather than constant electrospray, the DIMS and MS performance is normalized within an experiment, as signals are compared between individual mass spectra (ms time scale) rather than individual experiments (min-hr time scale). The platform was validated with lipid standards and extracts from nitrogen-deprived microalgae. Dual nESI-DIMS requires minimal system modification and is compatible with all traditional ion activation techniques and mass analyzers, making it a versatile improvement to shotgun lipidomics workflows.
Collapse
Affiliation(s)
- James E Keating
- Department of Chemistry , The University of North Carolina at Chapel Hill , Chapel Hill , North Carolina 27599 United States
| | - Gary L Glish
- Department of Chemistry , The University of North Carolina at Chapel Hill , Chapel Hill , North Carolina 27599 United States
| |
Collapse
|
207
|
Chai M, Young MN, Liu FC, Bleiholder C. A Transferable, Sample-Independent Calibration Procedure for Trapped Ion Mobility Spectrometry (TIMS). Anal Chem 2018; 90:9040-9047. [DOI: 10.1021/acs.analchem.8b01326] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
208
|
Garabedian A, Benigni P, Ramirez CE, Baker ES, Liu T, Smith RD, Fernandez-Lima F. Towards Discovery and Targeted Peptide Biomarker Detection Using nanoESI-TIMS-TOF MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:817-826. [PMID: 28889248 PMCID: PMC5844780 DOI: 10.1007/s13361-017-1787-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 07/29/2017] [Accepted: 08/10/2017] [Indexed: 05/12/2023]
Abstract
In the present work, the potential of trapped ion mobility spectrometry coupled to TOF mass spectrometry (TIMS-TOF MS) for discovery and targeted monitoring of peptide biomarkers from human-in-mouse xenograft tumor tissue was evaluated. In particular, a TIMS-MS workflow was developed for the detection and quantification of peptide biomarkers using internal heavy analogs, taking advantage of the high mobility resolution (R = 150-250) prior to mass analysis. Five peptide biomarkers were separated, identified, and quantified using offline nanoESI-TIMS-CID-TOF MS; the results were in good agreement with measurements using a traditional LC-ESI-MS/MS proteomics workflow. The TIMS-TOF MS analysis permitted peptide biomarker detection based on accurate mobility, mass measurements, and high sequence coverage for concentrations in the 10-200 nM range, while simultaneously achieving discovery measurements of not initially targeted peptides as markers from the same proteins and, eventually, other proteins. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Alyssa Garabedian
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL, 33199, USA
| | - Paolo Benigni
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL, 33199, USA
| | - Cesar E Ramirez
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL, 33199, USA
| | - Erin S Baker
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Tao Liu
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Richard D Smith
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Francisco Fernandez-Lima
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL, 33199, USA.
- Biomolecular Sciences Institute, Florida International University, Miami, FL, 33199, USA.
| |
Collapse
|
209
|
Adams KJ, Smith NF, Ramirez CE, Fernandez-Lima F. Discovery and targeted monitoring of polychlorinated biphenyl metabolites in blood plasma using LC-TIMS-TOF MS. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2018; 427:133-140. [PMID: 29915519 PMCID: PMC6003708 DOI: 10.1016/j.ijms.2017.11.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In the present work, the potential for rapid, targeted analysis of hydroxylated metabolites of polychlorinated biphenyls (OH-PCBs) in diluted human blood plasma using liquid chromatography coupled with trapped ion mobility spectrometry and TOF high resolution mass spectrometry (LC-TIMS-TOF MS) was evaluated. Experimental OH-PCB collisional cross section (CCSN2) and gas-phase candidate structures (<3% error) are reported for the first time and used, in addition to the LC retention time and accurate m/z, as OH-PCB identification features in order to increase the detection selectivity. The proposed LC-TIMS-TOF MS workflow combines a "dilute-and-shoot" sample preparation strategy, a robust liquid chromatography step, a high-resolving power mobility separation (R ~ 150-250) and high-resolution mass spectrometry (R ~ 30-40k) for the separation, identification and quantification of common OH-PCB isomers with limits of detection comparable to traditional workflows (e.g., LOD and LOQ of ~10 pg/mL and ~50 pg/mL, respectively). The higher selectivity and low detection limits provides multiple advantages compared to current methodologies that typically require long, labor-intensive preparation and/or derivatization steps prior to gas or liquid chromatography-mass spectrometry.
Collapse
Affiliation(s)
- Kendra J. Adams
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, United States
| | - Natalie F. Smith
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, United States
| | - Cesar E. Ramirez
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, United States
| | - Francisco Fernandez-Lima
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, United States
- Biomolecular Sciences Institute, Florida International University, Miami, FL 33199, United States
| |
Collapse
|
210
|
Righetti L, Bergmann A, Galaverna G, Rolfsson O, Paglia G, Dall'Asta C. Ion mobility-derived collision cross section database: Application to mycotoxin analysis. Anal Chim Acta 2018. [PMID: 29523251 DOI: 10.1016/j.aca.2018.01.047] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The recent hyphenation of ion mobility spectrometry (IMS) with high resolution mass spectrometry (HRMS) has risen as a powerful technique for both targeted and non-targeted screening, reducing background noise and allowing separation of isomeric and isobaric compounds. Nevertheless, such an approach remains largely unexplored in food safety applications, such as mycotoxin analysis. To implement ion mobility in routinely MS-based mycotoxin workflows, searchable databases with collusion cross section (CCS) values and accurate mass-values are required. This paper provides for the first time a traveling-wave IMS (TWIMS)-derived CCS database for mycotoxins, including more than 100 CCS values. The measurements showed high reproducibility (RSD < 2%) across different instrumental conditions as well as several complex cereal matrices, showing a mean inter-matrix precision of RSD <0.9%. As a proof of concept, the database was applied to the analysis of several spiked as well as naturally incurred cereal-based samples. In addition, the effect of adducts on the drift time was studied in a series of mycotoxins in order to understand potential deviations from expected drift time behaviors. Overall, our study confirmed that CCS values represent a physicochemical property that can be used alongside the traditional molecular identifiers of precursor ion accurate mass, fragment ions, isotopic pattern, and retention time.
Collapse
Affiliation(s)
- Laura Righetti
- Department of Food Science, University of Parma, Viale delle Scienze 17/A, I-43124 Parma, Italy
| | - Andreas Bergmann
- Center for Systems Biology, Medical Department, University of Iceland, Sturlugata 8, 101 Reykjavik, Iceland
| | - Gianni Galaverna
- Department of Food Science, University of Parma, Viale delle Scienze 17/A, I-43124 Parma, Italy
| | - Ottar Rolfsson
- Center for Systems Biology, Medical Department, University of Iceland, Sturlugata 8, 101 Reykjavik, Iceland
| | - Giuseppe Paglia
- Center of Biomedicine, European Academy of Bolzano/Bozen, Via Galvani 31, Bolzano 39100, Italy
| | - Chiara Dall'Asta
- Department of Food Science, University of Parma, Viale delle Scienze 17/A, I-43124 Parma, Italy.
| |
Collapse
|
211
|
Eyers CE, Vonderach M, Ferries S, Jeacock K, Eyers PA. Understanding protein–drug interactions using ion mobility–mass spectrometry. Curr Opin Chem Biol 2018; 42:167-176. [DOI: 10.1016/j.cbpa.2017.12.013] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 12/08/2017] [Accepted: 12/22/2017] [Indexed: 01/23/2023]
|
212
|
The application of ion mobility mass spectrometry to metabolomics. Curr Opin Chem Biol 2018; 42:60-66. [DOI: 10.1016/j.cbpa.2017.11.001] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Revised: 11/01/2017] [Accepted: 11/02/2017] [Indexed: 12/20/2022]
|
213
|
Prabhakaran A, Hamid AM, Garimella SVB, Valenzuela BR, Ewing RG, Ibrahim YM, Smith RD. A Hybrid Constant and Oscillatory Field Ion Mobility Analyzer Using Structures for Lossless Ion Manipulations. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:342-351. [PMID: 29235041 PMCID: PMC5815952 DOI: 10.1007/s13361-017-1841-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 10/25/2017] [Accepted: 10/30/2017] [Indexed: 05/12/2023]
Abstract
Here we explore the combination of constant and oscillatory fields applied in a single device to affect the continuous separation and filtering of ions based on their mobilities. The device explored allows confining and manipulating ions utilizing a combination of radio frequency (rf), direct current (DC) fields, and traveling waves (TW) in a structures for lossless ion manipulations (SLIM) module. We have investigated theoretically and experimentally a concept for continuous filtering of ions based on their mobilities where ions are mobility separated and selected by passage through two regions, both of which incorporated combined TW and constant fields providing opposing forces on the ions. The SLIM module was composed of two surfaces with mirror-image arrays of electrodes and had two regions where the different TW and opposing DC fields could be applied. The filtering capabilities are determined by the applied DC gradient and the TW parameters, such as speed, amplitude, and the TW sequence (i.e., the duty cycle of the traveling wave). The effects of different parameters on the sensitivity and the ion mobility (IM) resolution of the device have been investigated. By appropriately choosing the DC gradient and TW parameters for the two sections, it is possible to transmit ions of a selected mobility while filtering out others of both higher and lower mobility. The novel device described here provides a basis for the targeted analysis of compounds based upon the continuous selection of ions according to their mobility and without the need for high electric fields or pulsed injection. Graphical abstract ᅟ.
Collapse
Affiliation(s)
- Aneesh Prabhakaran
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Ahmed M Hamid
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Sandilya V B Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Blandina R Valenzuela
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Robert G Ewing
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA.
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA.
| |
Collapse
|
214
|
Ben-Nissan G, Sharon M. The application of ion-mobility mass spectrometry for structure/function investigation of protein complexes. Curr Opin Chem Biol 2018; 42:25-33. [PMID: 29128665 PMCID: PMC5796646 DOI: 10.1016/j.cbpa.2017.10.026] [Citation(s) in RCA: 92] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2017] [Revised: 10/19/2017] [Accepted: 10/24/2017] [Indexed: 12/16/2022]
Abstract
Ion-mobility mass spectrometry (IM-MS) is an approach that can provide information on the stoichiometry, composition, protein contacts and topology of protein complexes. The power of this approach lies not only in its sensitivity and speed of analysis, but also in the fact that it is a technique that can capture the repertoire of conformational states adopted by protein assemblies. Here, we describe the array of available IM-MS based tools, and demonstrate their application to the structural characterization of various protein complexes, including challenging systems as amyloid aggregates and membrane proteins. We also discuss recent studies in which IM-MS was applied towards investigations of conformational transitions and stabilization effects induced by protein interactions.
Collapse
Affiliation(s)
- Gili Ben-Nissan
- Department of Biomolecular Sciences, Weizmann Institute of Science, Rehovot 7610001, Israel
| | - Michal Sharon
- Department of Biomolecular Sciences, Weizmann Institute of Science, Rehovot 7610001, Israel.
| |
Collapse
|
215
|
Liu FC, Ridgeway ME, Park MA, Bleiholder C. Tandem trapped ion mobility spectrometry. Analyst 2018; 143:2249-2258. [DOI: 10.1039/c7an02054f] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Design, characteristics, and application of tandem trapped ion mobility spectrometry (TIMS-TIMS).
Collapse
Affiliation(s)
- Fanny C. Liu
- Department of Chemistry and Biochemistry
- Florida State University
- Tallahassee
- USA
| | | | | | - Christian Bleiholder
- Department of Chemistry and Biochemistry
- Florida State University
- Tallahassee
- USA
- Institute of Molecular Biophysics
| |
Collapse
|
216
|
Haler JRN, Massonnet P, Chirot F, Kune C, Comby-Zerbino C, Jordens J, Honing M, Mengerink Y, Far J, Dugourd P, De Pauw E. Comparison of Different Ion Mobility Setups Using Poly (Ethylene Oxide) PEO Polymers: Drift Tube, TIMS, and T-Wave. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:114-120. [PMID: 29027151 DOI: 10.1007/s13361-017-1822-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 09/20/2017] [Accepted: 09/25/2017] [Indexed: 06/07/2023]
Abstract
Over the years, polymer analyses using ion mobility-mass spectrometry (IM-MS) measurements have been performed on different ion mobility spectrometry (IMS) setups. In order to be able to compare literature data taken on different IM(-MS) instruments, ion heating and ion temperature evaluations have already been explored. Nevertheless, extrapolations to other analytes are difficult and thus straightforward same-sample instrument comparisons seem to be the only reliable way to make sure that the different IM(-MS) setups do not greatly change the gas-phase behavior. We used a large range of degrees of polymerization (DP) of poly(ethylene oxide) PEO homopolymers to measure IMS drift times on three different IM-MS setups: a homemade drift tube (DT), a trapped (TIMS), and a traveling wave (T-Wave) IMS setup. The drift time evolutions were followed for increasing polymer DPs (masses) and charge states, and they are found to be comparable and reproducible on the three instruments. ᅟ.
Collapse
Affiliation(s)
- Jean R N Haler
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium.
| | - Philippe Massonnet
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium
| | - Fabien Chirot
- Institut des Sciences Analytiques, Université de Lyon, Université Lyon1, Ens de Lyon, CNRS, 69100, Villeurbanne, France
| | - Christopher Kune
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium
| | - Clothilde Comby-Zerbino
- Institut Lumière Matière, Université de Lyon, Université Lyon 1, CNRS, 69100, Villeurbanne, France
| | | | | | | | - Johann Far
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium
| | - Philippe Dugourd
- Institut Lumière Matière, Université de Lyon, Université Lyon 1, CNRS, 69100, Villeurbanne, France
| | - Edwin De Pauw
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium
| |
Collapse
|
217
|
|
218
|
Zietek BM, Mengerink Y, Jordens J, Somsen GW, Kool J, Honing M. Adduct-ion formation in trapped ion mobility spectrometry as a potential tool for studying molecular structures and conformations. ACTA ACUST UNITED AC 2017. [DOI: 10.1007/s12127-017-0227-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
219
|
Morrison KA, Clowers BH. Contemporary glycomic approaches using ion mobility-mass spectrometry. Curr Opin Chem Biol 2017; 42:119-129. [PMID: 29248736 DOI: 10.1016/j.cbpa.2017.11.020] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Revised: 11/27/2017] [Accepted: 11/30/2017] [Indexed: 10/18/2022]
Abstract
Characterization of complex oligosaccharides has historically required extensive sample handling and separations before analysis using nuclear magnetic resonance spectroscopy and electron impact mass spectra following hydrolysis, derivatization, and gas chromatographic separation. Advances in liquid chromatography separations and tandem mass spectrometry have expanded the range of intact glycan analysis, but carbohydrate structure and conformation-integral chemical characteristics-are often difficult to assess with minimal amounts of sample in a rapid fashion. Because ion mobility spectrometry (IMS) separates analytes based upon an effective 'size-to-charge' ratio, IMS is, by extension, highly applicable to glycomics. Furthermore, the speed of IMS, its growing levels of separation efficiency, and direct compatibility with all forms of mass spectrometry, illustrates is core role in the future of glycomics efforts. This review assesses the current state of ion mobility-mass spectrometry applied to glycan, glycoprotein, and glycoconjugate analysis. Currently, assessing optimal ion polarity and adduct type for a glycan class along with the appropriate tandem mass spectrometry technique underpin many of the current glycan analysis efforts using ion mobility-mass spectrometry (IMMS). Once determined, these parameters have enabled a growing and impressive range of glycomics campaigns employing this technique. Additionally, the combination of IMS with tandem mass spectrometry, and even spectroscopic methods, further expands the dimensionality of hybrid instrumentation to provide a more comprehensive assessment of glycan structure across a wide dynamic range. Continued computational efforts to complement experimental and instrumental advancements also serve as a core component of IMMS workflows applied to glycomics and promise to maximize the information gained from mobility separations.
Collapse
Affiliation(s)
- Kelsey A Morrison
- Department of Chemistry, Washington State University, Pullman, WA 99164, United States
| | - Brian H Clowers
- Department of Chemistry, Washington State University, Pullman, WA 99164, United States.
| |
Collapse
|
220
|
Baglai A, Gargano AF, Jordens J, Mengerink Y, Honing M, van der Wal S, Schoenmakers PJ. Comprehensive lipidomic analysis of human plasma using multidimensional liquid- and gas-phase separations: Two-dimensional liquid chromatography–mass spectrometry vs. liquid chromatography–trapped-ion-mobility–mass spectrometry. J Chromatogr A 2017; 1530:90-103. [DOI: 10.1016/j.chroma.2017.11.014] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 11/06/2017] [Accepted: 11/09/2017] [Indexed: 01/04/2023]
|
221
|
D'Atri V, Causon T, Hernandez-Alba O, Mutabazi A, Veuthey JL, Cianferani S, Guillarme D. Adding a new separation dimension to MS and LC-MS: What is the utility of ion mobility spectrometry? J Sep Sci 2017; 41:20-67. [PMID: 29024509 DOI: 10.1002/jssc.201700919] [Citation(s) in RCA: 115] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 09/19/2017] [Accepted: 09/19/2017] [Indexed: 12/12/2022]
Abstract
Ion mobility spectrometry is an analytical technique known for more than 100 years, which entails separating ions in the gas phase based on their size, shape, and charge. While ion mobility spectrometry alone can be useful for some applications (mostly security analysis for detecting certain classes of narcotics and explosives), it becomes even more powerful in combination with mass spectrometry and high-performance liquid chromatography. Indeed, the limited resolving power of ion mobility spectrometry alone can be tackled when combining this analytical strategy with mass spectrometry or liquid chromatography with mass spectrometry. Over the last few years, the hyphenation of ion mobility spectrometry to mass spectrometry or liquid chromatography with mass spectrometry has attracted more and more interest, with significant progresses in both technical advances and pioneering applications. This review describes the theoretical background, available technologies, and future capabilities of these techniques. It also highlights a wide range of applications, from small molecules (natural products, metabolites, glycans, lipids) to large biomolecules (proteins, protein complexes, biopharmaceuticals, oligonucleotides).
Collapse
Affiliation(s)
- Valentina D'Atri
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva, Switzerland
| | - Tim Causon
- Division of Analytical Chemistry, Department of Chemistry, University of Natural Resources and Life Sciences (BOKU Vienna), Vienna, Austria
| | - Oscar Hernandez-Alba
- BioOrganic Mass Spectrometry Laboratory (LSMBO), IPHC, Université de Strasbourg, CNRS, Strasbourg, France
| | - Aline Mutabazi
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva, Switzerland
| | - Jean-Luc Veuthey
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva, Switzerland
| | - Sarah Cianferani
- BioOrganic Mass Spectrometry Laboratory (LSMBO), IPHC, Université de Strasbourg, CNRS, Strasbourg, France
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva, Switzerland
| |
Collapse
|
222
|
Chalet C, Hollebrands B, Janssen HG, Augustijns P, Duchateau G. Identification of phase-II metabolites of flavonoids by liquid chromatography–ion-mobility spectrometry–mass spectrometry. Anal Bioanal Chem 2017; 410:471-482. [DOI: 10.1007/s00216-017-0737-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 10/18/2017] [Accepted: 10/30/2017] [Indexed: 10/18/2022]
|
223
|
Dodds JN, May JC, McLean JA. Correlating Resolving Power, Resolution, and Collision Cross Section: Unifying Cross-Platform Assessment of Separation Efficiency in Ion Mobility Spectrometry. Anal Chem 2017; 89:12176-12184. [PMID: 29039942 PMCID: PMC5744666 DOI: 10.1021/acs.analchem.7b02827] [Citation(s) in RCA: 126] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Here we examine the relationship among resolving power (Rp), resolution (Rpp), and collision cross section (CCS) for compounds analyzed in previous ion mobility (IM) experiments representing a wide variety of instrument platforms and IM techniques. Our previous work indicated these three variables effectively describe and predict separation efficiency for drift tube ion mobility spectrometry experiments. In this work, we seek to determine if our previous findings are a general reflection of IM behavior that can be applied to various instrument platforms and mobility techniques. Results suggest IM distributions are well characterized by a Gaussian model and separation efficiency can be predicted on the basis of the empirical difference in the gas-phase CCS and a CCS-based resolving power definition (CCS/ΔCCS). Notably traveling wave (TWIMS) was found to operate at resolutions substantially higher than a single-peak resolving power suggested. When a CCS-based Rp definition was utilized, TWIMS was found to operate at a resolving power between 40 and 50, confirming the previous observations by Giles and co-workers. After the separation axis (and corresponding resolving power) is converted to cross section space, it is possible to effectively predict separation behavior for all mobility techniques evaluated (i.e., uniform field, trapped ion mobility, traveling wave, cyclic, and overtone instruments) using the equations described in this work. Finally, we are able to establish for the first time that the current state-of-the-art ion mobility separations benchmark at a CCS-based resolving power of >300 that is sufficient to differentiate analyte ions with CCS differences as small as 0.5%.
Collapse
Affiliation(s)
| | | | - John A. McLean
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville Tennessee 37235, United States
| |
Collapse
|
224
|
The potential of Ion Mobility Mass Spectrometry for high-throughput and high-resolution lipidomics. Curr Opin Chem Biol 2017; 42:42-50. [PMID: 29145156 DOI: 10.1016/j.cbpa.2017.10.018] [Citation(s) in RCA: 72] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 10/12/2017] [Accepted: 10/13/2017] [Indexed: 11/23/2022]
Abstract
Lipids are a large and highly diverse family of biomolecules, which play essential structural, storage and signalling roles in cells and tissues. Although traditional mass spectrometry (MS) approaches used in lipidomics are highly sensitive and selective, lipid analysis remains challenging due to the chemical diversity of lipid structures, multiple isobaric species and incomplete separation using many forms of chromatography. Ion mobility (IM) separates ions in the gas phase based on their physicochemical properties. Addition of IM to the traditional lipidomic workflow both enhances separation of complex lipid mixtures, beneficial for lipid identification, and improves isomer resolution. Herein, we discuss the recent developments in IM-MS for lipidomics.
Collapse
|
225
|
Haler JRN, Kune C, Massonnet P, Comby-Zerbino C, Jordens J, Honing M, Mengerink Y, Far J, De Pauw E. Comprehensive Ion Mobility Calibration: Poly(ethylene oxide) Polymer Calibrants and General Strategies. Anal Chem 2017; 89:12076-12086. [DOI: 10.1021/acs.analchem.7b02564] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Jean R. N. Haler
- Mass
Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du
Six Aout 11, B-4000 Liège, Belgium
| | - Christopher Kune
- Mass
Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du
Six Aout 11, B-4000 Liège, Belgium
| | - Philippe Massonnet
- Mass
Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du
Six Aout 11, B-4000 Liège, Belgium
| | - Clothilde Comby-Zerbino
- Institut
Lumière Matière, Université de Lyon, Université Lyon 1, CNRS, 69100 Villeurbanne, France
| | | | | | | | - Johann Far
- Mass
Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du
Six Aout 11, B-4000 Liège, Belgium
| | - Edwin De Pauw
- Mass
Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du
Six Aout 11, B-4000 Liège, Belgium
| |
Collapse
|
226
|
The potential of ion mobility-mass spectrometry for non-targeted metabolomics. Curr Opin Chem Biol 2017; 42:9-15. [PMID: 29107931 DOI: 10.1016/j.cbpa.2017.10.015] [Citation(s) in RCA: 81] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 10/10/2017] [Accepted: 10/12/2017] [Indexed: 12/31/2022]
Abstract
Non-targeted analysis of metabolites in hypothesis-generating workflows has proven its potential to answer essential questions that arise when dealing with complex biological systems. Nevertheless, tracking changes in perturbed systems via accurate quantification and the identification process itself represent the most critical challenges in these workflows. Recent advances in ion mobility-mass spectrometry have enabled this technique to increase the confidence of metabolite annotation by introducing a complementary conditional molecular descriptor, that is collision cross section.
Collapse
|
227
|
Zheng X, Aly NA, Zhou Y, Dupuis KT, Bilbao A, Paurus VL, Orton DJ, Wilson R, Payne SH, Smith RD, Baker ES. A structural examination and collision cross section database for over 500 metabolites and xenobiotics using drift tube ion mobility spectrometry. Chem Sci 2017; 8:7724-7736. [PMID: 29568436 PMCID: PMC5853271 DOI: 10.1039/c7sc03464d] [Citation(s) in RCA: 138] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Accepted: 09/21/2017] [Indexed: 12/19/2022] Open
Abstract
The confident identification of metabolites and xenobiotics in biological and environmental studies is an analytical challenge due to their immense dynamic range, vast chemical space and structural diversity. Ion mobility spectrometry (IMS) is widely used for small molecule analyses since it can separate isomeric species and be easily coupled with front end separations and mass spectrometry for multidimensional characterizations. However, to date IMS metabolomic and exposomic studies have been limited by an inadequate number of accurate collision cross section (CCS) values for small molecules, causing features to be detected but not confidently identified. In this work, we utilized drift tube IMS (DTIMS) to directly measure CCS values for over 500 small molecules including primary metabolites, secondary metabolites and xenobiotics. Since DTIMS measurements do not need calibrant ions or calibration like some other IMS techniques, they avoid calibration errors which can cause problems in distinguishing structurally similar molecules. All measurements were performed in triplicate in both positive and negative polarities with nitrogen gas and seven different electric fields, so that relative standard deviations (RSD) could be assessed for each molecule and structural differences studied. The primary metabolites analyzed to date have come from key metabolism pathways such as glycolysis, the pentose phosphate pathway and the tricarboxylic acid cycle, while the secondary metabolites consisted of classes such as terpenes and flavonoids, and the xenobiotics represented a range of molecules from antibiotics to polycyclic aromatic hydrocarbons. Different CCS trends were observed for several of the diverse small molecule classes and when urine features were matched to the database, the addition of the IMS dimension greatly reduced the possible number of candidate molecules. This CCS database and structural information are freely available for download at http://panomics.pnnl.gov/metabolites/ with new molecules being added frequently.
Collapse
Affiliation(s)
- Xueyun Zheng
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Noor A Aly
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Yuxuan Zhou
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Kevin T Dupuis
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Aivett Bilbao
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Vanessa L Paurus
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Daniel J Orton
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Ryan Wilson
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Samuel H Payne
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Richard D Smith
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| | - Erin S Baker
- Biological Sciences Division , Pacific Northwest National Laboratory , 902 Battelle Blvd, P.O. Box 999, MSIN K8-98 , Richland , WA 99352 , USA . ; Tel: +1-509-371-6219
| |
Collapse
|
228
|
Haler JRN, Far J, Aqil A, Claereboudt J, Tomczyk N, Giles K, Jérôme C, De Pauw E. Multiple Gas-Phase Conformations of a Synthetic Linear Poly(acrylamide) Polymer Observed Using Ion Mobility-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2492-2499. [PMID: 28808984 DOI: 10.1007/s13361-017-1769-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 07/14/2017] [Accepted: 07/20/2017] [Indexed: 06/07/2023]
Abstract
Ion mobility-mass spectrometry (IM-MS) has emerged as a powerful separation and identification tool to characterize synthetic polymer mixtures and topologies (linear, cyclic, star-shaped,…). Electrospray coupled to IM-MS already revealed the coexistence of several charge state-dependent conformations for a single charge state of biomolecules with strong intramolecular interactions, even when limited resolving power IM-MS instruments were used. For synthetic polymers, the sample's polydispersity allows the observation of several chain lengths. A unique collision cross-section (CCS) trend is usually observed when increasing the degree of polymerization (DP) at constant charge state, allowing the deciphering of different polymer topologies. In this paper, we report multiple coexisting CCS trends when increasing the DP at constant charge state for linear poly(acrylamide) PAAm in the gas phase. This is similar to observations on peptides and proteins. Biomolecules show in addition population changes when collisionally heating the ions. In the case of synthetic PAAm, fragmentation occurred before reaching the energy for conformation conversion. These observations, which were made on two different IM-MS instruments (SYNAPT G2 HDMS and high resolution multi-pass cyclic T-Wave prototype from Waters), limit the use of ion mobility for synthetic polymer topology interpretations to polymers where unique CCS values are observed for each DP at constant charge state. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Jean R N Haler
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium.
| | - Johann Far
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium
| | - Abdelhafid Aqil
- Center for Education and Research on Macromolecules, Department of Chemistry, University of Liège, Quartier Agora, Allée du Six Aout 13, B-4000, Liège, Belgium
| | - Jan Claereboudt
- Waters Corporation, Connexion Business Park, Brusselsesteenweg 500, 1731, Zellik, Belgium
| | - Nick Tomczyk
- Waters Corporation, Stamford Ave., Wilmslow, SK9 4AX, UK
| | - Kevin Giles
- Waters Corporation, Stamford Ave., Wilmslow, SK9 4AX, UK
| | - Christine Jérôme
- Center for Education and Research on Macromolecules, Department of Chemistry, University of Liège, Quartier Agora, Allée du Six Aout 13, B-4000, Liège, Belgium
| | - Edwin De Pauw
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium
| |
Collapse
|
229
|
Abstract
Mass spectrometry (MS) is an analytical technique for determining the composition of a sample. In bottom-up techniques, peptide mass fingerprinting (PMF) is widely used to identify proteins from MS dataset. In this article, the authors developed a novel network-based inference software termed NBPMF. By analyzing peptide-protein bipartite network, they designed new peptide protein matching score functions. They present two methods: the static one, ProbS, is based on an independent probability framework; and the dynamic one, HeatS, depicts input data as dependent peptides. The authors also use linear regression to adjust the matching score according to the masses of proteins. In addition, they consider the order of retention time to further correct the score function. In post processing, a peak can only be assigned to one peptide in order to reduce random matches. Finally, the authors try to filter out false positive proteins. The experiments on simulated and real data demonstrate that their NBPMF approaches lead to significantly improved performance compared to several state-of-the-art methods.
Collapse
Affiliation(s)
- Zhewei Liang
- Department of Computer Science, University of Western Ontario, London, Canada
| | - Gilles Lajoie
- Department of Biochemistry, University of Western Ontario, London, Canada
| | - Kaizhong Zhang
- Department of Computer Science, University of Western Ontario, London, Canada
| |
Collapse
|
230
|
Nahin M, Oberreit D, Fukushima N, Larriba-Andaluz C. Modeling of an Inverted Drift Tube for Improved Mobility Analysis of Aerosol Particles. Sci Rep 2017; 7:6456. [PMID: 28744005 PMCID: PMC5527120 DOI: 10.1038/s41598-017-06448-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Accepted: 06/13/2017] [Indexed: 01/29/2023] Open
Abstract
A new mobility particle analyzer, which has been termed Inverted Drift Tube, has been modeled analytically as well as numerically and proven to be a very capable instrument. The basis for the new design have been the shortcomings of the previous ion mobility spectrometers, in particular (a) diffusional broadening which leads to degradation of instrument resolution and (b) inadequate low and fixed resolution (not mobility dependent) for large sizes. To overcome the diffusional broadening and have a mobility based resolution, the IDT uses two varying controllable opposite forces, a flow of gas with velocity v gas , and a linearly increasing electric field that opposes the movement. A new parameter, the separation ratio Λ = v drift /v gas , is employed to determine the best possible separation for a given set of nanoparticles. Due to the system's need to operate at room pressure, two methods of capturing the ions at the end of the drift tube have been developed, Intermittent Push Flow for a large range of mobilities, and Nearly-Stopping Potential Separation, with very high separation but limited only to a narrow mobility range. A chromatography existing concept of resolving power is used to differentiate between peak resolution in the IDT and acceptable separation between similar mobility sizes.
Collapse
Affiliation(s)
- Minal Nahin
- Integrated Nanosystems Development Institute(INDI), IUPUI, Department of Mechanical Engineering, Indianapolis, IN, 46106, USA
| | | | | | - Carlos Larriba-Andaluz
- Integrated Nanosystems Development Institute(INDI), IUPUI, Department of Mechanical Engineering, Indianapolis, IN, 46106, USA.
| |
Collapse
|
231
|
Zheng X, Wojcik R, Zhang X, Ibrahim YM, Burnum-Johnson KE, Orton DJ, Monroe ME, Moore RJ, Smith RD, Baker ES. Coupling Front-End Separations, Ion Mobility Spectrometry, and Mass Spectrometry For Enhanced Multidimensional Biological and Environmental Analyses. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2017; 10:71-92. [PMID: 28301728 PMCID: PMC5627998 DOI: 10.1146/annurev-anchem-061516-045212] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. Though IMS alone is useful, its coupling with mass spectrometry (MS) and front-end separations is extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information available from biological and environmental sample analyses. In fact, multiple disease screening and environmental evaluations have illustrated that the IMS-based multidimensional separations extract information that cannot be acquired with each technique individually. This review highlights three-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography, supercritical fluid chromatography, liquid chromatography, solid-phase extractions, capillary electrophoresis, field asymmetric ion mobility spectrometry, and microfluidic devices. The origination, current state, various applications, and future capabilities of these multidimensional approaches are described in detail to provide insight into their uses and benefits.
Collapse
Affiliation(s)
- Xueyun Zheng
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Roza Wojcik
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Xing Zhang
- Skaggs School of Pharmacy and Pharmaceutical Sciences, Anschutz Medical Campus, University of Colorado, Denver, Colorado 80045
| | - Yehia M Ibrahim
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Kristin E Burnum-Johnson
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Daniel J Orton
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Matthew E Monroe
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Ronald J Moore
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Richard D Smith
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Erin S Baker
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| |
Collapse
|
232
|
Hofmann J, Pagel K. Glykananalyse mittels Ionenmobilitäts-Massenspektrometrie. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/ange.201701309] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Affiliation(s)
- Johanna Hofmann
- Abteilung Molekülphysik; Fritz-Haber-Institut der Max-Planck-Gesellschaft; Faradayweg 4-6 14195 Berlin Deutschland
| | - Kevin Pagel
- Institut für Chemie und Biochemie; Freie Universität Berlin; Takustraße 3 Deutschland
| |
Collapse
|
233
|
Hofmann J, Pagel K. Glycan Analysis by Ion Mobility-Mass Spectrometry. Angew Chem Int Ed Engl 2017; 56:8342-8349. [DOI: 10.1002/anie.201701309] [Citation(s) in RCA: 107] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Revised: 04/03/2017] [Indexed: 12/31/2022]
Affiliation(s)
- Johanna Hofmann
- Abteilung Molekülphysik; Fritz-Haber-Institut der Max-Planck-Gesellschaft; Faradayweg 4-6 14195 Berlin Germany
| | - Kevin Pagel
- Institut für Chemie und Biochemie; Freie Universität Berlin; Takustraße 3 Germany
| |
Collapse
|
234
|
Benigni P, Sandoval K, Thompson CJ, Ridgeway ME, Park MA, Gardinali P, Fernandez-Lima F. Analysis of Photoirradiated Water Accommodated Fractions of Crude Oils Using Tandem TIMS and FT-ICR MS. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:5978-5988. [PMID: 28457132 PMCID: PMC5661887 DOI: 10.1021/acs.est.7b00508] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
For the first time, trapped ion mobility spectrometry (TIMS) in tandem with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is applied to the analysis of the low energy water accommodated fraction (WAF) of a crude oil as a function of the exposure to light. The TIMS-FT-ICR MS analysis provided, in addition to the heteroatom series identification, new insights into the WAF isomeric complexity (e.g., [m/z; chemical formula; collision cross section] data sets) for a better evaluation of the degree of chemical and structural photoinduced transformations. Inspection of the [m/z; chemical formula; collision cross section] data sets shows that the WAF composition changes as a function of the exposure to light in the first 115 h by initial photosolubilization of HC components and their photo-oxidation up to O4-5 of mainly high double bond equivalence species (DBE > 9). The addition of high resolution TIMS (resolving power of 90-220) to ultrahigh resolution FT-ICR MS (resolving power over 400k) permitted the identification of a larger number of molecular components in a single analysis (e.g., over 47k using TIMS-MS compared to 12k by MS alone), with instances of over 6-fold increase in the number of molecular features per nominal mass due to the WAF isomeric complexity. This work represents a stepping stone toward a better understanding of the WAF components and highlights the need for better experimental and theoretical approaches to characterize the WAF structural diversity.
Collapse
Affiliation(s)
- Paolo Benigni
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
| | - Kathia Sandoval
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
| | | | | | - Melvin A. Park
- Bruker Daltonics, Inc., Billerica, Massachusetts 01821, USA
| | - Piero Gardinali
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
- Southeast Environmental Research Center, Florida International University, Miami, Florida 33199, USA
| | - Francisco Fernandez-Lima
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
- Biomolecular Sciences Institute, Florida International University, Miami, FL 33199
| |
Collapse
|
235
|
Hollerbach A, Baird Z, Cooks RG. Ion Separation in Air Using a Three-Dimensional Printed Ion Mobility Spectrometer. Anal Chem 2017; 89:5058-5065. [PMID: 28383249 DOI: 10.1021/acs.analchem.7b00469] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Adam Hollerbach
- Chemistry
Department, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | | | - R. Graham Cooks
- Chemistry
Department, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| |
Collapse
|
236
|
Ibrahim YM, Hamid AM, Deng L, Garimella SVB, Webb IK, Baker ES, Smith RD. New frontiers for mass spectrometry based upon structures for lossless ion manipulations. Analyst 2017; 142:1010-1021. [PMID: 28262893 PMCID: PMC5431593 DOI: 10.1039/c7an00031f] [Citation(s) in RCA: 90] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Structures for lossless ion manipulations (SLIM) provide a new paradigm for efficient, complex and extended gas phase ion manipulations. SLIM are created from electric fields generated by the application of DC and RF potentials to arrays of electrodes patterned on two parallel surfaces. The electric fields provide lossless ion manipulations, including effective ion transport and storage. SLIM modules have been developed using both constant and oscillatory electric fields (e.g. traveling waves) to affect the ion motion. Ion manipulations demonstrated to date with SLIM include: extended trapping, ion selection, ion dissociation, and ion mobility spectrometry (IMS) separations achieving unprecedented ultra high resolution. SLIM thus provide the basis for previously impractical manipulations, such as very long path length ion mobility separations where ions traverse a serpentine path multiple times, as well as new capabilities that extend the utility of these developments based on temporal and spatial compression of ion mobility separations and other ion distributions. The evolution of SLIM devices developed over the last three years is reviewed and we provide examples of various ion manipulations performed, and briefly discuss potential applications and new directions.
Collapse
Affiliation(s)
- Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, USA
| | - Ahmed M Hamid
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, USA
| | - Liulin Deng
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, USA
| | - Sandilya V B Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, USA
| | - Ian K Webb
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, USA
| | - Erin S Baker
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, USA
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, USA
| |
Collapse
|
237
|
Paglia G, Astarita G. Metabolomics and lipidomics using traveling-wave ion mobility mass spectrometry. Nat Protoc 2017; 12:797-813. [PMID: 28301461 DOI: 10.1038/nprot.2017.013] [Citation(s) in RCA: 168] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Metabolomics and lipidomics aim to profile the wide range of metabolites and lipids that are present in biological samples. Recently, ion mobility spectrometry (IMS) has been used to support metabolomics and lipidomics applications to facilitate the separation and the identification of complex mixtures of analytes. IMS is a gas-phase electrophoretic technique that enables the separation of ions in the gas phase according to their charge, shape and size. Occurring within milliseconds, IMS separation is compatible with modern mass spectrometry (MS) operating with microsecond scan speeds. Thus, the time required for acquiring IMS data does not affect the overall run time of traditional liquid chromatography (LC)-MS-based metabolomics and lipidomics experiments. The addition of IMS to conventional LC-MS-based metabolomics and lipidomics workflows has been shown to enhance peak capacity, spectral clarity and fragmentation specificity. Moreover, by enabling determination of a collision cross-section (CCS) value-a parameter related to the shape of ions-IMS can improve the accuracy of metabolite identification. In this protocol, we describe how to integrate traveling-wave ion mobility spectrometry (TWIMS) into traditional LC-MS-based metabolomic and lipidomic workflows. In particular, we describe procedures for the following: tuning and calibrating a SYNAPT High-Definition MS (HDMS) System (Waters) specifically for metabolomics and lipidomics applications; extracting polar metabolites and lipids from brain samples; setting up appropriate chromatographic conditions; acquiring simultaneously m/z, retention time and CCS values for each analyte; processing and analyzing data using dedicated software solutions, such as Progenesis QI (Nonlinear Dynamics); and, finally, performing metabolite and lipid identification using CCS databases and TWIMS-derived fragmentation information.
Collapse
Affiliation(s)
- Giuseppe Paglia
- Center for Biomedicine, European Academy of Bolzano/Bozen, Bolzano, Italy
| | - Giuseppe Astarita
- Department of Biochemistry and Molecular &Cellular Biology, Georgetown University, Washington, DC, USA
| |
Collapse
|
238
|
Wesdemiotis C. Multidimensional Mass Spectrometry of Synthetic Polymers and Advanced Materials. Angew Chem Int Ed Engl 2017; 56:1452-1464. [PMID: 27712048 DOI: 10.1002/anie.201607003] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Revised: 10/02/2016] [Indexed: 01/06/2023]
Abstract
Multidimensional mass spectrometry interfaces a suitable ionization technique and mass analysis (MS) with fragmentation by tandem mass spectrometry (MS2 ) and an orthogonal online separation method. Separation choices include liquid chromatography (LC) and ion-mobility spectrometry (IMS), in which separation takes place pre-ionization in the solution state or post-ionization in the gas phase, respectively. The MS step provides elemental composition information, while MS2 exploits differences in the bond stabilities of a polymer, yielding connectivity and sequence information. LC conditions can be tuned to separate by polarity, end-group functionality, or hydrodynamic volume, whereas IMS adds selectivity by macromolecular shape and architecture. This Minireview discusses how selected combinations of the MS, MS2 , LC, and IMS dimensions can be applied, together with the appropriate ionization method, to determine the constituents, structures, end groups, sequences, and architectures of a wide variety of homo- and copolymeric materials, including multicomponent blends, supramolecular assemblies, novel hybrid materials, and large cross-linked or nonionizable polymers.
Collapse
Affiliation(s)
- Chrys Wesdemiotis
- Department of Chemistry, The University of Akron, Akron, OH, 44325, USA
| |
Collapse
|
239
|
Wesdemiotis C. Mehrdimensionale Massenspektrometrie von synthetischen Polymeren und modernen Materialien. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/ange.201607003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Chrys Wesdemiotis
- Department of Chemistry; The University of Akron; Akron OH 44325 USA
| |
Collapse
|
240
|
Abstract
In this review, we focus on an important aspect of ion mobility (IM) research, namely the reporting of quantitative ion mobility measurements in the form of the gas-phase collision cross section (CCS), which has provided a common basis for comparison across different instrument platforms and offers a unique form of structural information, namely size and shape preferences of analytes in the absence of bulk solvent. This review surveys the over 24,000 CCS values reported from IM methods spanning the era between 1975 to 2015, which provides both a historical and analytical context for the contributions made thus far, as well as insight into the future directions that quantitative ion mobility measurements will have in the analytical sciences. The analysis was conducted in 2016, so CCS values reported in that year are purposely omitted. In another few years, a review of this scope will be intractable, as the number of CCS values which will be reported in the next three to five years is expected to exceed the total amount currently published in the literature.
Collapse
Affiliation(s)
- Jody C May
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| | - Caleb B Morris
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| | - John A McLean
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| |
Collapse
|
241
|
Kirk AT, Raddatz CR, Zimmermann S. Separation of Isotopologues in Ultra-High-Resolution Ion Mobility Spectrometry. Anal Chem 2017; 89:1509-1515. [DOI: 10.1021/acs.analchem.6b03300] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Ansgar T. Kirk
- Leibniz Universität Hannover, Institute of Electrical Engineering
and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Christian-Robert Raddatz
- Leibniz Universität Hannover, Institute of Electrical Engineering
and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Leibniz Universität Hannover, Institute of Electrical Engineering
and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| |
Collapse
|
242
|
Metz TO, Baker ES, Schymanski EL, Renslow RS, Thomas DG, Causon TJ, Webb IK, Hann S, Smith RD, Teeguarden JG. Integrating ion mobility spectrometry into mass spectrometry-based exposome measurements: what can it add and how far can it go? Bioanalysis 2017; 9:81-98. [PMID: 27921453 PMCID: PMC5674211 DOI: 10.4155/bio-2016-0244] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Accepted: 10/12/2016] [Indexed: 01/01/2023] Open
Abstract
Measuring the exposome remains a challenge due to the range and number of anthropogenic molecules that are encountered in our daily lives, as well as the complex systemic responses to these exposures. One option for improving the coverage, dynamic range and throughput of measurements is to incorporate ion mobility spectrometry (IMS) into current MS-based analytical methods. The implementation of IMS in exposomics studies will lead to more frequent observations of previously undetected chemicals and metabolites. LC-IMS-MS will provide increased overall measurement dynamic range, resulting in detections of lower abundance molecules. Alternatively, the throughput of IMS-MS alone will provide the opportunity to analyze many thousands of longitudinal samples over lifetimes of exposure, capturing evidence of transitory accumulations of chemicals or metabolites. The volume of data corresponding to these new chemical observations will almost certainly outpace the generation of reference data to enable their confident identification. In this perspective, we briefly review the state-of-the-art in measuring the exposome, and discuss the potential use for IMS-MS and the physico-chemical property of collisional cross section in both exposure assessment and molecular identification.
Collapse
Affiliation(s)
- Thomas O Metz
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Erin S Baker
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Emma L Schymanski
- Eawag, Swiss Federal Institute of Aquatic Science & Technology, Dübendorf, Switzerland
| | - Ryan S Renslow
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Dennis G Thomas
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Tim J Causon
- Division of Analytical Chemistry, Department of Chemistry, University of Natural Resources & Life Sciences (BOKU Vienna), Vienna, Austria
| | - Ian K Webb
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Stephan Hann
- Division of Analytical Chemistry, Department of Chemistry, University of Natural Resources & Life Sciences (BOKU Vienna), Vienna, Austria
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | - Justin G Teeguarden
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
- Department of Environmental & Molecular Toxicology, Oregon State University, Corvallis, OR, USA
| |
Collapse
|
243
|
Ibrahim YM, Garimella SVB, Prost SA, Wojcik R, Norheim RV, Baker ES, Rusyn I, Smith RD. Development of an Ion Mobility Spectrometry-Orbitrap Mass Spectrometer Platform. Anal Chem 2016; 88:12152-12160. [PMID: 28193022 PMCID: PMC6211177 DOI: 10.1021/acs.analchem.6b03027] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Complex samples benefit from multidimensional measurements where higher resolution enables more complete characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometer (IMS-Orbitrap MS) platform. To circumvent the time scale disparity between the fast IMS separation and the much slower Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequences to multiplex the injection of ions and allow operation in signal averaging (SA), single multiplexing (SM), and double multiplexing (DM) IMS modes to optimize the signal-to-noise ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data. A new algorithm was developed for the DM analyses involving a two-step process that first recovers the SM data and then decodes the SM data. The algorithm also performs multiple refining procedures to minimize demultiplexing artifacts. The new IMS-Orbitrap MS platform was demonstrated by the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulas.
Collapse
Affiliation(s)
- Yehia M. Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Sandilya V. B. Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Spencer A. Prost
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Roza Wojcik
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Randolph V. Norheim
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Erin S. Baker
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Ivan Rusyn
- Department of Veterinary Integrative Biosciences, Texas A&M University, College Station, Texas 77843, United States
| | - Richard D. Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| |
Collapse
|
244
|
Garimella SVB, Hamid AM, Deng L, Ibrahim YM, Webb IK, Baker ES, Prost SA, Norheim RV, Anderson GA, Smith RD. Squeezing of Ion Populations and Peaks in Traveling Wave Ion Mobility Separations and Structures for Lossless Ion Manipulations Using Compression Ratio Ion Mobility Programming. Anal Chem 2016; 88:11877-11885. [PMID: 27934097 PMCID: PMC5470847 DOI: 10.1021/acs.analchem.6b03660] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
In this work we report an approach for spatial and temporal gas-phase ion population manipulation, wherein we collapse ion distributions in ion mobility (IM) separations into tighter packets providing higher sensitivity measurements in conjunction with mass spectrometry (MS). We do this for ions moving from a conventional traveling wave (TW)-driven region to a region where the TW is intermittently halted or "stuttered". This approach causes the ion packets spanning a number of TW-created traveling traps (TT) to be redistributed into fewer TT, resulting in spatial compression. The degree of spatial compression is controllable and determined by the ratio of stationary time of the TW in the second region to its moving time. This compression ratio ion mobility programming (CRIMP) approach has been implemented using "structures for lossless ion manipulations" (SLIM) in conjunction with MS. CRIMP with the SLIM-MS platform is shown to provide increased peak intensities, reduced peak widths, and improved signal-to-noise (S/N) ratios with MS detection. CRIMP also provides a foundation for extremely long path length and multipass IM separations in SLIM providing greatly enhanced IM resolution by reducing the detrimental effects of diffusional peak broadening and increasing peak widths.
Collapse
Affiliation(s)
| | | | | | - Yehia M. Ibrahim
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Ian K. Webb
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Erin S. Baker
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Spencer A. Prost
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Randolph V. Norheim
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | | | - Richard D. Smith
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| |
Collapse
|
245
|
Righetti L, Paglia G, Galaverna G, Dall'Asta C. Recent Advances and Future Challenges in Modified Mycotoxin Analysis: Why HRMS Has Become a Key Instrument in Food Contaminant Research. Toxins (Basel) 2016; 8:E361. [PMID: 27918432 PMCID: PMC5198555 DOI: 10.3390/toxins8120361] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2016] [Revised: 11/23/2016] [Accepted: 11/25/2016] [Indexed: 01/24/2023] Open
Abstract
Mycotoxins are secondary metabolites produced by pathogenic fungi in crops worldwide. These compounds can undergo modification in plants, leading to the formation of a large number of possible modified forms, whose toxicological relevance and occurrence in food and feed is still largely unexplored. The analysis of modified mycotoxins by liquid chromatography-mass spectrometry remains a challenge because of their chemical diversity, the large number of isomeric forms, and the lack of analytical standards. Here, the potential benefits of high-resolution and ion mobility mass spectrometry as a tool for separation and structure confirmation of modified mycotoxins have been investigated/reviewed.
Collapse
Affiliation(s)
- Laura Righetti
- Department of Food Science, University of Parma, Parco Area delle Scienze 95/A, Parma 43124, Italy.
| | - Giuseppe Paglia
- Center of Biomedicine, European Academy of Bolzano/Bozen, Via Galvani 31, Bolzano 39100, Italy.
| | - Gianni Galaverna
- Department of Food Science, University of Parma, Parco Area delle Scienze 95/A, Parma 43124, Italy.
| | - Chiara Dall'Asta
- Department of Food Science, University of Parma, Parco Area delle Scienze 95/A, Parma 43124, Italy.
| |
Collapse
|
246
|
Ortmayr K, Causon TJ, Hann S, Koellensperger G. Increasing selectivity and coverage in LC-MS based metabolome analysis. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.06.011] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
247
|
Gray C, Thomas B, Upton R, Migas L, Eyers C, Barran P, Flitsch S. Applications of ion mobility mass spectrometry for high throughput, high resolution glycan analysis. Biochim Biophys Acta Gen Subj 2016; 1860:1688-709. [DOI: 10.1016/j.bbagen.2016.02.003] [Citation(s) in RCA: 108] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Revised: 02/01/2016] [Accepted: 02/02/2016] [Indexed: 12/21/2022]
|
248
|
Pu Y, Ridgeway ME, Glaskin RS, Park MA, Costello CE, Lin C. Separation and Identification of Isomeric Glycans by Selected Accumulation-Trapped Ion Mobility Spectrometry-Electron Activated Dissociation Tandem Mass Spectrometry. Anal Chem 2016; 88:3440-3. [PMID: 26959868 PMCID: PMC4821751 DOI: 10.1021/acs.analchem.6b00041] [Citation(s) in RCA: 93] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
One of the major challenges in structural characterization of oligosaccharides is the presence of many structural isomers in most naturally occurring glycan mixtures. Although ion mobility spectrometry (IMS) has shown great promise in glycan isomer separation, conventional IMS separation occurs on the millisecond time scale, largely restricting its implementation to fast time-of-flight (TOF) analyzers which often lack the capability to perform electron activated dissociation (ExD) tandem MS analysis and the resolving power needed to resolve isobaric fragments. The recent development of trapped ion mobility spectrometry (TIMS) provides a promising new tool that offers high mobility resolution and compatibility with high-performance Fourier transform ion cyclotron resonance (FTICR) mass spectrometers when operated under the selected accumulation-TIMS (SA-TIMS) mode. Here, we present our initial results on the application of SA-TIMS-ExD-FTICR MS to the separation and identification of glycan linkage isomers.
Collapse
Affiliation(s)
- Yi Pu
- Center for Biomedical Mass Spectrometry, Boston University School of Medicine, Boston, MA 02118, US
| | | | - Rebecca S. Glaskin
- Center for Biomedical Mass Spectrometry, Boston University School of Medicine, Boston, MA 02118, US
| | | | - Catherine E. Costello
- Center for Biomedical Mass Spectrometry, Boston University School of Medicine, Boston, MA 02118, US
| | - Cheng Lin
- Center for Biomedical Mass Spectrometry, Boston University School of Medicine, Boston, MA 02118, US
| |
Collapse
|
249
|
Silveira JA, Michelmann K, Ridgeway ME, Park MA. Fundamentals of Trapped Ion Mobility Spectrometry Part II: Fluid Dynamics. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:585-595. [PMID: 26864793 DOI: 10.1007/s13361-015-1310-z] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 11/02/2015] [Accepted: 11/06/2015] [Indexed: 06/05/2023]
Abstract
Trapped ion mobility spectrometry (TIMS) is a new high resolution (R up to ~300) separation technique that utilizes an electric field to hold ions stationary against a moving gas. Recently, an analytical model for TIMS was derived and, in part, experimentally verified. A central, but not yet fully explored, component of the model involves the fluid dynamics at work. The present study characterizes the fluid dynamics in TIMS using simulations and ion mobility experiments. Results indicate that subsonic laminar flow develops in the analyzer, with pressure-dependent gas velocities between ~120 and 170 m/s measured at the position of ion elution. One of the key philosophical questions addressed is: how can mobility be measured in a dynamic system wherein the gas is expanding and its velocity is changing? We noted previously that the analytically useful work is primarily done on ions as they traverse the electric field gradient plateau in the analyzer. In the present work, we show that the position-dependent change in gas velocity on the plateau is balanced by a change in pressure and temperature, ultimately resulting in near position-independent drag force. That the drag force, and related variables, are nearly constant allows for the use of relatively simple equations to describe TIMS behavior. Nonetheless, we derive a more comprehensive model, which accounts for the spatial dependence of the flow variables. Experimental resolving power trends were found to be in close agreement with the theoretical dependence of the drag force, thus validating another principal component of TIMS theory.
Collapse
Affiliation(s)
| | | | - Mark E Ridgeway
- Bruker Daltonics, 40 Manning Road, Billerica, MA, 01821, USA
| | - Melvin A Park
- Bruker Daltonics, 40 Manning Road, Billerica, MA, 01821, USA.
| |
Collapse
|
250
|
Ridgeway ME, Wolff JJ, Silveira JA, Lin C, Costello CE, Park MA. Gated Trapped Ion Mobility Spectrometry Coupled to Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. ACTA ACUST UNITED AC 2016; 19:77-85. [PMID: 27667964 DOI: 10.1007/s12127-016-0197-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Analysis of molecules by ion mobility spectrometry coupled with mass spectrometry (IMS-MS) provides chemical information on the three dimensional structure and mass of the molecules. The coupling of ion mobility to trapping mass spectrometers has historically been challenging due to the large differences in analysis time between the two devices. In this paper we present a modification of the trapped ion mobility (TIMS) analysis scheme termed "Gated TIMS" that allows efficient coupling to a Fourier Transform Ion Cyclotron Resonance (FT-ICR) analyzer. Analyses of standard compounds and the influence of source conditions on the TIMS distributions produced by ion mobility spectra of labile ubiquitin protein ions are presented. Ion mobility resolving powers up to 100 are observed. Measured collisional cross sections of ubiquitin ions are in excellent qualitative and quantitative agreement to previous measurements. Gated TIMS FT-ICR produces results comparable to those acquired using TIMS/time-of-flight MS instrument platforms as well as numerous drift tube IMS-MS studies published in the literature.
Collapse
Affiliation(s)
| | | | | | - Cheng Lin
- Mass Spectrometry Resource, Department of Biochemistry, Boston University School of Medicine, 670 Albany Street, Suite 504, Boston, MA 02118
| | - Catherine E Costello
- Mass Spectrometry Resource, Department of Biochemistry, Boston University School of Medicine, 670 Albany Street, Suite 504, Boston, MA 02118
| | - Melvin A Park
- Bruker Daltonics, 40 Manning Rd, Billerica, MA 01821
| |
Collapse
|