201
|
Glorieux G, Neirynck N, Veys N, Vanholder R. Dialysis water and fluid purity: more than endotoxin. Nephrol Dial Transplant 2012; 27:4010-21. [DOI: 10.1093/ndt/gfs306] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
202
|
Prakash S, Pinti M, Bhushan B. Theory, fabrication and applications of microfluidic and nanofluidic biosensors. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2012; 370:2269-2303. [PMID: 22509059 DOI: 10.1098/rsta.2011.0498] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Biosensors are a broad array of devices that detect the type and amount of a biological species or biomolecule. Several different types of biosensors have been developed that rely on changes to mechanical, chemical or electrical properties of the transduction or sensing element to induce a measurable signal. Often, a biosensor will integrate several functions or unit operations such as sample extraction, manipulation and detection on a single platform. This review begins with an overview of the current state-of-the-art biosensor field. Next, the review delves into a special class of biosensors that rely on microfluidics and nanofluidics by presenting the underlying theory, fabrication and several examples and applications of microfluidic and nanofluidic sensors.
Collapse
Affiliation(s)
- Shaurya Prakash
- Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, 43210, USA.
| | | | | |
Collapse
|
203
|
Abstract
The development of a miniaturized sensing platform tailored for sensitive and selective detection of a variety of biochemical analytes could offer transformative fundamental and technological opportunities. Due to their high surface-to-volume ratios, nanoscale materials are extremely sensitive sensors. Likewise, peptides represent robust substrates for selective recognition due to the potential for broad chemical diversity within their relatively compact size. Here we explore the possibilities of linking peptides to nanosensors for the selective detection of biochemical targets. Such systems raise a number of interesting fundamental challenges: What are the peptide sequences, and how can rational design be used to derive selective binders? What nanomaterials should be used, and what are some strategies for assembling hybrid nanosensors? What role does molecular modeling play in elucidating response mechanisms? What is the resulting performance of these sensors, in terms of sensitivity, selectivity, and response time? What are some potential applications? This Account will highlight our early attempts to address these research challenges. Specifically, we use natural peptide sequences or sequences identified from phage display as capture elements. The sensors are based on a variety of nanomaterials including nanowires, graphene, and carbon nanotubes. We couple peptides to the nanomaterial surfaces via traditional surface functionalization methods or self-assembly. Molecular modeling provides detailed insights into the hybrid nanostructure, as well as the sensor detection mechanisms. The peptide nanosensors can distinguish chemically camouflaged mixtures of vapors and detect chemical warfare agents with sensitivities as low as parts-per-billion levels. Finally, we anticipate future uses of this technology in biomedicine: for example, devices based on these sensors could detect disease from the molecular components in human breath. Overall, these results provide a novel platform for the development of highly sensitive and selective "nanoelectronic noses".
Collapse
Affiliation(s)
- Yue Cui
- Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, New Jersey 08544, United States
- Department of Biological Engineering, Utah State University, Logan, Utah 84322, United States
| | - Sang N. Kim
- Air Force Research Laboratory, Materials & Manufacturing Directorate, Wright-Patterson Air Force Base, Dayton, Ohio 45433, United States
| | - Rajesh R. Naik
- Air Force Research Laboratory, Materials & Manufacturing Directorate, Wright-Patterson Air Force Base, Dayton, Ohio 45433, United States
| | - Michael C. McAlpine
- Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, New Jersey 08544, United States
| |
Collapse
|
204
|
North SH, Wojciechowski J, Chu V, Taitt CR. Surface immobilization chemistry influences peptide-based detection of lipopolysaccharide and lipoteichoic acid. J Pept Sci 2012; 18:366-72. [PMID: 22565661 DOI: 10.1002/psc.2399] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2011] [Revised: 11/27/2011] [Accepted: 01/04/2012] [Indexed: 01/21/2023]
Abstract
Antimicrobial peptides (AMPs) have recently gained attention as potentially valuable diagnostic and therapeutic agents. The utilization of these peptides for diagnostic purposes relies on the ability to immobilize them on the surface of a detection platform in a predictable and reliable manner that facilitates target binding. The method for attachment of peptides to a solid support is guided by peptide length, amino acid composition, secondary structure, and the nature of the underlying substrate. While immobilization methods that target amine groups of amino acid sequences are widely used, they can result in heterogeneous conjugation at multiple sites on a peptide and have direct implications for peptide presentation and function. Using two types of commercial amine-reactive microtiter plates, we described the effects of analogous immobilization chemistries on the surface attachment of AMPs and their differential binding interaction with Gram-specific bacterial biomarkers, lipopolysaccharide and lipoteichoic acid. As might be expected, differences in overall binding affinities were noted when comparing AMPs immobilized on the two types of plates. However, the two-amine-targeted linking chemistries also affected the specificity of the attached peptides; lipopolysaccharide generally demonstrated a preference for peptides immobilized on one type of plate, while (when observed at all) lipoteichoic acid bound preferentially to AMPs immobilized on the other type of plate. These results demonstrate the potential for tuning not only the binding affinities but also the specificities of immobilized AMPs by simple alterations in linking strategy.
Collapse
Affiliation(s)
- Stella H North
- Center for Bio/Molecular Science & Engineering, Naval Research Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375, USA
| | | | | | | |
Collapse
|
205
|
Chamberlain JW, Maurer K, Cooper J, Lyon WJ, Danley DL, Ratner DM. Microelectrode array biosensor for studying carbohydrate-mediated interactions. Biosens Bioelectron 2012; 34:253-60. [PMID: 22405843 PMCID: PMC3832429 DOI: 10.1016/j.bios.2012.02.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2011] [Revised: 02/04/2012] [Accepted: 02/10/2012] [Indexed: 11/16/2022]
Abstract
Carbohydrate-mediated host-pathogen interactions are essential to bacterial and viral pathogenesis, and represent an attractive target for the development of antiadhesives to prevent infection. We present a versatile microelectrode array-based platform to investigate carbohydrate-mediated protein and bacterial binding, with the objective of developing a generalizable method for screening inhibitors of host-microbe interactions. Microelectrode arrays are well suited for interrogating biological binding events, including proteins and whole-cells, and are amenable to electrochemical derivitization, facilitating rapid deposition of biomolecules. In this study, we achieve microelectrode functionalization with carbohydrates via controlled polymerization of pyrrole to individual microelectrodes, followed by physisorption of neoglycoconjugates to the polypyrrole-coated electrodes. Bioactivity of the immobilized carbohydrates was confirmed with carbohydrate-binding proteins (lectins) detected by both fluorescent and electrochemical means. The platform's ability to analyze whole-cell binding was demonstrated using strains of Escherichia coli and Salmonella enterica, and the dose-dependent inhibition of S. enterica by a soluble carbohydrate antiadhesive.
Collapse
Affiliation(s)
- Jeffrey W. Chamberlain
- Department of Bioengineering, University of Washington, Box 355061, Seattle, WA 98195, USA
| | - Karl Maurer
- CombiMatrix, 310 Goddard, Suite 150, Irvine, CA 92618, USA
| | - John Cooper
- CombiMatrix, 310 Goddard, Suite 150, Irvine, CA 92618, USA
| | - Wanda J. Lyon
- Air Force Research Laboratory, Wright Patterson Air Force Base, 2510 Fifth Street, Area B B840, Dayton, OH 45433, USA
| | | | - Daniel M. Ratner
- Department of Bioengineering, University of Washington, Box 355061, Seattle, WA 98195, USA
| |
Collapse
|
206
|
Mannoor MS, Tao H, Clayton JD, Sengupta A, Kaplan DL, Naik RR, Verma N, Omenetto FG, McAlpine MC. Graphene-based wireless bacteria detection on tooth enamel. Nat Commun 2012; 3:763. [PMID: 22453836 DOI: 10.1038/ncomms1767] [Citation(s) in RCA: 454] [Impact Index Per Article: 37.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2011] [Accepted: 02/29/2012] [Indexed: 12/22/2022] Open
Abstract
Direct interfacing of nanosensors onto biomaterials could impact health quality monitoring and adaptive threat detection. Graphene is capable of highly sensitive analyte detection due to its nanoscale nature. Here we show that graphene can be printed onto water-soluble silk. This in turn permits intimate biotransfer of graphene nanosensors onto biomaterials, including tooth enamel. The result is a fully biointerfaced sensing platform, which can be tuned to detect target analytes. For example, via self-assembly of antimicrobial peptides onto graphene, we show bioselective detection of bacteria at single-cell levels. Incorporation of a resonant coil eliminates the need for onboard power and external connections. Combining these elements yields two-tiered interfacing of peptide-graphene nanosensors with biomaterials. In particular, we demonstrate integration onto a tooth for remote monitoring of respiration and bacteria detection in saliva. Overall, this strategy of interfacing graphene nanosensors with biomaterials represents a versatile approach for ubiquitous detection of biochemical targets.
Collapse
Affiliation(s)
- Manu S Mannoor
- Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, New Jersey 08544, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
207
|
Shriver-Lake LC, North SH, Dean SN, Taitt CR. Antimicrobial Peptides for Detection and Diagnostic Assays. SPRINGER SERIES ON CHEMICAL SENSORS AND BIOSENSORS 2012. [DOI: 10.1007/5346_2012_19] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
208
|
Short peptides as biosensor transducers. Anal Bioanal Chem 2011; 402:3055-70. [DOI: 10.1007/s00216-011-5589-8] [Citation(s) in RCA: 128] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2011] [Revised: 10/25/2011] [Accepted: 11/20/2011] [Indexed: 12/27/2022]
|
209
|
Guo X, Kulkarni A, Doepke A, Halsall HB, Iyer S, Heineman WR. Carbohydrate-based label-free detection of Escherichia coli ORN 178 using electrochemical impedance spectroscopy. Anal Chem 2011; 84:241-6. [PMID: 22035288 DOI: 10.1021/ac202419u] [Citation(s) in RCA: 110] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
A label-free biosensor for Escherichia coli (E. coli) ORN 178 based on faradaic electrochemical impedance spectroscopy (EIS) was developed. α-Mannoside or β-galactoside was immobilized on a gold disk electrode using a self-assembled monolayer (SAM) via a spacer terminated in a thiol functionality. Impedance measurements (Nyquist plot) showed shifts due to the binding of E. coli ORN 178, which is specific for α-mannoside. No significant change in impedance was observed for E. coli ORN 208, which does not bind to α-mannoside. With increasing concentrations of E. coli ORN 178, electron-transfer resistance (R(et)) increases before the sensor is saturated. After the Nyquist plot of E. coli/mixed SAM/gold electrode was modeled, a linear relationship between normalized R(et) and the logarithmic value of E. coli concentrations was found in a range of bacterial concentration from 10(2) to 10(3) CFU/mL. The combination of robust carbohydrate ligands with EIS provides a label-free, sensitive, specific, user-friendly, robust, and portable biosensing system that could potentially be used in a point-of-care or continuous environmental monitoring setting.
Collapse
Affiliation(s)
- Xuefei Guo
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221-0172, USA
| | | | | | | | | | | |
Collapse
|
210
|
Brouwer CPJM, Rahman M, Welling MM. Discovery and development of a synthetic peptide derived from lactoferrin for clinical use. Peptides 2011; 32:1953-63. [PMID: 21827807 DOI: 10.1016/j.peptides.2011.07.017] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2011] [Revised: 07/22/2011] [Accepted: 07/22/2011] [Indexed: 01/11/2023]
Abstract
There is an urgent need to develop new antimicrobial drugs especially for combating the rise of infections caused by multi-resistant pathogens such as MRSA and VRSA. The problem of antibiotic resistant micro-organisms is expected to increase disproportionally and controlling of infections is becoming difficult because of the rapid spread of those micro-organisms. Primary therapy with classical antibiotics is becoming more ineffective. Combinational therapy of antibiotics with antimicrobial peptides (AMP's) has been suggested as an alternative approach to improve treatment outcome. Their unique mechanism of action and safety profile makes AMP's appealing candidates for simultaneous or sequential use in different cases of infections. In this review, for antimicrobial treatment the application of synthetic antimicrobial peptide hLF(1-11), derived from the first 11 amino acids of human lactoferrin is evaluated in both pre-clinical and clinical settings. Present information indicates that this derivate from lactoferrin is well tolerated in pre-clinical tests and clinical trials and thus hLF(1-11) is an interesting candidate for further exploration in various clinical indications of obscure infections, including meningitis. Another approach of using AMP's is their use in prevention of infections e.g. as coating for dental or bone implants or in biosensing applications or useful as infection specific radiopharmaceutical.
Collapse
Affiliation(s)
- Carlo P J M Brouwer
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, Room C4-R-77, Leiden, The Netherlands
| | | | | |
Collapse
|
211
|
Li Y, Santos CM, Kumar A, Zhao M, Lopez AI, Qin G, McDermott AM, Cai C. "Click" immobilization on alkylated silicon substrates: model for the study of surface bound antimicrobial peptides. Chemistry 2011; 17:2656-65. [PMID: 21264959 PMCID: PMC3257173 DOI: 10.1002/chem.201001533] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2010] [Revised: 10/17/2010] [Indexed: 11/12/2022]
Abstract
We describe an effective approach for the covalent immobilization of antimicrobial peptides (AMPs) to bioinert substrates via Cu(I) -catalyzed azide-alkyne cycloaddition (CuAAC). The bioinert substrates were prepared by surface hydrosilylation of oligo(ethylene glycol) (OEG) terminated alkenes on hydrogen-terminated silicon surfaces. To render the OEG monolayers "clickable", mixed monolayers were prepared using OEG-alkenes with and without a terminal alkyne protected by a trimethylgermanyl (TMG) group. The mixed monolayers were characterized by X-ray photoelectron spectroscopy (XPS), elliposometry and contact angle measurement. The TMG protecting group can be readily removed to yield a free terminal alkyne by catalytic amounts of Cu(I) in an aqueous media. This step can then be combined with the subsequent CuAAC reaction. Thus, the immobilization of an azide modified AMP (N3-IG-25) was achieved in a one-pot deprotection/coupling reaction. Varying the ratio of the two alkenes in the deposition mixture allowed for control over the density of the alkynyl groups in the mixed monolayer, and subsequently the coverage of the AMPs on the monolayer. These samples allowed for study of the dependence of antimicrobial activities on the AMP density. The results show that a relative low coverage of AMPs (∼1.6×10(13) molecule per cm(2)) is sufficient to significantly suppress the viability of Pseudomonas aeruginosa, while the surface presenting the highest density of AMPs (∼2.8×10(13) molecule per cm(2)) is still cyto-compatible. The remarkable antibacterial activity is attributed to the long and flexible linker and the site-specific "click" immobilization, which may facilitate the covalently attached peptides to interact with and disrupt the bacterial membranes.
Collapse
Affiliation(s)
- Yan Li
- Department: Department of Chemistry & Center for Materials Chemistry, University of Houston, Houston, TX 77204 (USA), Fax: (+1)713-743-2709
| | - Catherine M. Santos
- Department: Department of Chemistry & Center for Materials Chemistry, University of Houston, Houston, TX 77204 (USA), Fax: (+1)713-743-2709
| | - Amit Kumar
- Department: Department of Chemistry & Center for Materials Chemistry, University of Houston, Houston, TX 77204 (USA), Fax: (+1)713-743-2709
| | - Meirong Zhao
- Department: Department of Chemistry & Center for Materials Chemistry, University of Houston, Houston, TX 77204 (USA), Fax: (+1)713-743-2709
| | - Analette I. Lopez
- Department: Department of Chemistry & Center for Materials Chemistry, University of Houston, Houston, TX 77204 (USA), Fax: (+1)713-743-2709
| | - Guoting Qin
- Department: Department of Chemistry & Center for Materials Chemistry, University of Houston, Houston, TX 77204 (USA), Fax: (+1)713-743-2709
| | | | - Chengzhi Cai
- Department: Department of Chemistry & Center for Materials Chemistry, University of Houston, Houston, TX 77204 (USA), Fax: (+1)713-743-2709
| |
Collapse
|
212
|
Lee D, Chander Y, Goyal SM, Cui T. Carbon nanotube electric immunoassay for the detection of swine influenza virus H1N1. Biosens Bioelectron 2011; 26:3482-7. [PMID: 21354779 PMCID: PMC7126489 DOI: 10.1016/j.bios.2011.01.029] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2010] [Revised: 01/20/2011] [Accepted: 01/20/2011] [Indexed: 11/06/2022]
Abstract
A low-cost, label-free, ultra-sensitive electric immunoassay is developed for the detection of swine influenza virus (SIV) H1N1. The assay is based on the excellent electrical properties of single-walled carbon nanotubes (SWCNTs). Antibody–virus complexes influence the conductance of underlying SWCNT thin film, which has been constructed by facile layer-by-layer self-assembly. The basic steps of conventional immunoassay are performed followed by the electric characterization of immunochips at the last stage. The resistance of immunochips tends to increase upon surface adsorption of macromolecules such as poly-l-lysine, anti-SIV antibodies, and SIVs during the assay. The resistance shift after the binding of SIV with anti-SIV antibody is normalized with the resistances of bare devices. The sensor selectivity tests are performed with non-SIVs, showing the normalized resistance shift of 12% as a background. The detection limit of 180 TCID50/ml of SIV is obtained suggesting a potential application of this assay as point-of-care detection or monitoring system. This facile CNT-based immunoassay also has the potential to be used as a sensing platform for lab-on-a-chip system.
Collapse
Affiliation(s)
- Dongjin Lee
- Department of Mechanical Engineering, University of Minnesota, 111 Church St. S.E., Minneapolis, MN 55455, USA
| | | | | | | |
Collapse
|