1
|
Fang R, Yi LX, Shao YX, Zhang L, Chen GH. ON-LINE PRECONCENTRATION IN CAPILLARY ELECTROPHORESIS FOR ANALYSIS OF AGROCHEMICAL RESIDUES. J LIQ CHROMATOGR R T 2014. [DOI: 10.1080/10826076.2013.794740] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Rou Fang
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| | - Ling-Xiao Yi
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| | - Yu-Xiu Shao
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| | - Li Zhang
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| | - Guan-Hua Chen
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| |
Collapse
|
2
|
Aramendía MA, Borau V, Lafont F, Marinas A, Marinas JM, Moreno JM, Porras JM, Urbano FJ. Determination of diquat and paraquat in olive oil by ion-pair liquid chromatography–electrospray ionization mass spectrometry (MRM). Food Chem 2006. [DOI: 10.1016/j.foodchem.2005.05.005] [Citation(s) in RCA: 78] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
3
|
Simó C, Barbas C, Cifuentes A. Capillary electrophoresis-mass spectrometry in food analysis. Electrophoresis 2005; 26:1306-18. [PMID: 15761921 DOI: 10.1002/elps.200410108] [Citation(s) in RCA: 97] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This work provides an updated overview (including works published till June 2004) on the principal applications of capillary electrophoresis-mass spectrometry (CE-MS) together with their main advantages and drawbacks in food science. Thus, analysis of amino acids, peptides, proteins, carbohydrates, or polyphenols by CE-MS in different foods is reviewed. Also, other natural compounds (e.g., alkaloids) and toxins analyzed by CE-MS in foods are revised. Moreover, exogenous substances with a potential risk for human health (e.g., pesticides, drugs) detected in foods by CE-MS are included in this work. The usefulness of CE-MS for food analysis and the information that this coupling can provide in terms of processing, composition, authenticity, quality, or safety of foods is also discussed.
Collapse
Affiliation(s)
- Carolina Simó
- Department of Food Analysis, Institute of Industrial Fermentations (CSIC) Madrid, Spain
| | | | | |
Collapse
|
4
|
Time-of-flight high resolution versus triple quadrupole tandem mass spectrometry for the analysis of quaternary ammonium herbicides in drinking water. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2004.08.006] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
5
|
Hernández-Borges J, Frías-García S, Cifuentes A, Rodríguez-Delgado MA. Pesticide analysis by capillary electrophoresis. J Sep Sci 2004; 27:947-63. [PMID: 15352712 DOI: 10.1002/jssc.200401820] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In this work, a critical and updated revision of the current situation of the analysis of pesticides by Capillary Electrophoresis (CE) is presented. The review has been written in two main sections. The first one presents a thorough revision of the various offline and on-line sample preconcentration procedures that have been used in conjunction with CE to analyze these compounds. The second part reviews the various detection strategies (i.e., UV, LIF, MS, and electrochemical) and CE modes that have been applied to the analysis of pesticides. Future trends that can be expected from this hot research area are also discussed.
Collapse
Affiliation(s)
- J Hernández-Borges
- Department of Analytical Chemistry, Nutrition and Food Science, University of La Laguna, 38071 Tenerife, Spain
| | | | | | | |
Collapse
|
6
|
Balcerzak M. An overview of analytical applications of time of flight-mass spectrometric (TOF-MS) analyzers and an inductively coupled plasma-TOF-MS technique. ANAL SCI 2003; 19:979-89. [PMID: 12880079 DOI: 10.2116/analsci.19.979] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A brief overview of the applications of time-of-flight mass spectrometry (TOF-MS) for analytical purposes is presented. The performance of TOF-MS combined with an inductively coupled plasma (ICP) ion source is discussed in detail. The advantages of TOF-MS detectors over the quadrupole mass filters for multi-elemental analysis of fast transient signals are discussed. The applications of ICP-TOF-MS for the detection of signals from laser ablation, electrothermal vaporization, gas and liquid chromatography, capillary electrophoresis and flow-injection analysis are reviewed.
Collapse
Affiliation(s)
- Maria Balcerzak
- Department of Analytical Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland.
| |
Collapse
|
7
|
Jouyban A, Grosse SC, Chan HK, Coleman MW, Clark BJ. Mathematical representation of electrophoretic mobility of basic drugs in ternary solvent buffers in capillary zone electrophoresis. J Chromatogr A 2003; 994:191-8. [PMID: 12779229 DOI: 10.1016/s0021-9673(03)00387-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The electrophoretic mobilities of two beta-blocker drugs, i.e., labetalol and atenolol, have been determined in a mixed solvent background electrolyte system containing sodium acetate+acetic acid as buffering agent and different volume fractions of water, methanol and ethanol using capillary electrophoresis. The produced data and three other sets collected from a recent work are employed to study the accuracy and prediction capability of a mathematical model to calculate the electrophoretic mobility with respect to the volume fractions of the solvents in the mixture. The results show that the proposed model is able to correlate/predict the mobility within an acceptable error range and it is possible to use the model in industry to achieve the optimum solvent composition for the buffer where using a ternary solvent system is required. The average percentage deviations (APDs) obtained for correlated and predicted data points are 0.71-2.48 and 1.72-4.39%, respectively. The accuracy of the proposed model is compared with that of a mixture response surface method and the results show that the proposed model is superior from both correlation and prediction points of view. The possibility of calculation of the mobility of chemically related drugs in water-methanol-ethanol mixtures using the proposed model is also shown and the produced prediction APD is approximately 8%.
Collapse
Affiliation(s)
- A Jouyban
- School of Pharmacy, Tabriz University of Medical Sciences, Tabriz 51664, Iran
| | | | | | | | | |
Collapse
|
8
|
Núñez O, Moyano E, Galceran MT. Capillary electrophoresis-mass spectrometry for the analysis of quaternary ammonium herbicides. J Chromatogr A 2002; 974:243-55. [PMID: 12458941 DOI: 10.1016/s0021-9673(02)00906-8] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Conditions for the simultaneous determination of the three herbicides paraquat, diquat and difenzoquat and the two plant growth regulators chlormequat and mepiquat by pressure-assisted capillary electrophoresis coupled to mass spectrometry (ion-trap) using electrospray as ionisation source have been established. A 200 mM formic acid-ammonium formate buffer solution at pH 3.0 with 50% of methanol was used as carrier electrolyte. Some capillary electrophoresis-mass spectrometry parameters such as sheath liquid and sheath gas flow-rates, sheath liquid composition, electrospray voltage andthe CE capillary position were optimised. The MS and MS-MS spectra of positive ions were studied in order to obtain structural information for the confirmation of the identity. The use of labelled standards allowed to confirm fragment ions assignation. The detection limits, based on a signal-to-noise ratio of 3:1, were between 0.5 and 2.5 mg l(-1) with hydrodynamic injection (10 s) and between 1 and 10 microg l(-1) with elecrokinetic injection (20 s, 10 kV) using standards in ultrapure water. Quality parameters such as linearity and run-to-run precision (n=6) were established. Quantitation was carried out using labelled standards. The method has been applied to the analysis of contaminated irrigation water and spiked mineral water samples.
Collapse
Affiliation(s)
- Oscar Núñez
- Departament de Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, E-08028 Barcelona, Spain
| | | | | |
Collapse
|
9
|
Núñez O, Kim JB, Moyano E, Galceran MT, Terabe S. Analysis of the herbicides paraquat, diquat and difenzoquat in drinking water by micellar electrokinetic chromatography using sweeping and cation selective exhaustive injection. J Chromatogr A 2002; 961:65-75. [PMID: 12186392 DOI: 10.1016/s0021-9673(02)00031-6] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Optimum conditions for the determination of the herbicides paraquat, diquat and difenzoquat by micellar electrokinetic chromatography (MEKC) using sweeping and cation-selective exhaustive injection (CSEI) as on-line concentration methods were developed. Sodium dodecyl sulfate (80 mM) in 50 mM phosphate buffer (pH 2.5) with 20% acetonitrile was used as a background electrolyte for the methods studied. The limits of detection, based on a signal-to-noise ratio of 3:1, were about 2.6-5.1 mg 1(-1) in purified water when MEKC was applied for the standards. By using an on-line preconcentration method known as sweeping-MEKC, up to a 500-fold increase in detection sensitivity was obtained whereas up to a 50 000-fold increase for CSEI-sweeping-MEKC was achieved. The limits of detection using optimum CSEI-sweeping-MEKC were lower than 1 microg 1(-1) and the method was validated obtaining good reproducibility (relative standard deviation lower than 22%) and linearity. CSEI-sweeping-MEKC was successfully applied to the determination of the three herbicides in spiked tap water below the levels established by the US Environmental Protection Agency.
Collapse
Affiliation(s)
- Oscar Núñez
- Faculty of Science, Himeji Institute of Technology, Kamigori, Hyogo, Japan.
| | | | | | | | | |
Collapse
|
10
|
Grey L, Nguyen B, Yang P. Liquid chromatography-electrospray ionization isotope dilution mass spectrometry analysis of paraquat and diquat using conventional and multilayer solid-phase extraction cartridges. J Chromatogr A 2002; 958:25-33. [PMID: 12134823 DOI: 10.1016/s0021-9673(02)00400-4] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The performance of alkyl-silica sorbent packed solid-phase extraction (SPE) cartridges and a mixed-mode, polymeric sorbent packed SPE cartridge (resin SPE cartridge) were evaluated for the sample preparation of paraquat and diquat in environmental water and vegetation matrices. Also the recoveries of the native and 2H-labeled paraquat and diquat were correlated to validate that the 2H-labeled species can be used for the isotopic dilution mass spectrometry (IDMS) analysis of paraquat and diquat. The results show that the extraction efficiency of alkyl-silica SPE is dependent on the carbon loading of the sorbent and deteriorates with an increasing sample pH. The resin SPE cartridge required no pH adjustment and showed excellent correlation between the native and 2H-labeled species, therefore, allowing us to develop the first liquid chromatography-electrospray ionization IDMS analytical method for the analysis of paraquat and diquat in environmental water and vegetation matrices. Method detection limits derived using standard EPA protocol were 0.2 and 0.1 microg/l for paraquat and diquat in water matrices, and 0.02 and 0.01 microg/g in vegetation matrices, respectively.
Collapse
Affiliation(s)
- Lorna Grey
- Applied Chromatography Section, Ontario Ministry of Environment, Etobicoke, Canada
| | | | | |
Collapse
|
11
|
Núñez O, Moyano E, Galceran MT. Solid-phase extraction and sample stacking-capillary electrophoresis for the determination of quaternary ammonium herbicides in drinking water. J Chromatogr A 2002; 946:275-82. [PMID: 11873975 DOI: 10.1016/s0021-9673(01)01562-x] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Conditions for the simultaneous determination of paraquat, diquat and difenzoquat by capillary zone electrophoresis were established by combining two preconcentration procedures. Off-line solid-phase extraction was used for the isolation and preconcentration of quats in drinking water. Quats were then analysed by capillary electrophoresis using sample stacking with matrix removal as on-column preconcentration procedure. Two different porous graphitic carbon cartridges were compared. The breakthrough volumes of the three herbicides were calculated and the loading capacity of the sorbents was compared. Recoveries higher than 80% for difenzoquat and around 40% for paraquat and diquat were obtained when a sample volume of 250 ml was percolated. For the stacking-capillary electrophoresis analysis of quats, 50 mM acetic acid-ammonium acetate (pH 4.0), 0.8 mM cetyltrimethylammonium bromide with 5% (v/v) methanol as carrier electrolyte was used. Detection limits, based on a signal-to-noise ratio of 3:1, were lower than 0.3 microg l(-1) for standards in Milli-Q water, and lower than 2.2 microg l(-1) for drinking water samples. Run-to-run and day-to-day precision of the method were established. The two preconcentration procedures used together was successfully applied to the analysis of the three herbicides in spiked drinking water at concentrations below the maximum admissible US Environmental Protection Agency levels.
Collapse
Affiliation(s)
- O Núñez
- Departament de Química Analítica, Facultat de Química, Universitat de Barcelona, Spain
| | | | | |
Collapse
|
12
|
Núñez O, Moyano E, Puignou L, Galceran MT. Sample stacking with matrix removal for the determination of paraquat, diquat and difenzoquat in water by capillary electrophoresis. J Chromatogr A 2001; 912:353-61. [PMID: 11330805 DOI: 10.1016/s0021-9673(01)00582-9] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Conditions for the simultaneous determination of paraquat, diquat and difenzoquat by capillary zone electrophoresis using a stacking technique in a chemically modified capillary have been established. To apply the stacking method with sample matrix removal for the analysis of cations, an anodic electroosmotic flow is mandatory. For quats, 50 mM acetic acid-ammonium acetate (pH 4.0) with 5% (v/v) methanol as electrophoretic buffer and the addition of 0.8 mM cetyltrimethylammonium bromide as wall capillary organic modifier was proposed. Field polarity reversal time was optimised for several sample matrices. Detection was carried out at 220 and 255 nm. Detection limits, based on a signal-to-noise ratio of 3:1, were lower than 15 microg l(-1) for standards in Milli-Q water and two to ten times higher for drinking water samples. Run-to-run and day-to-day reproducibility have been established. The method was successfully applied to the determination of the three herbicides in spiked drinking water.
Collapse
Affiliation(s)
- O Núñez
- Departament de Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès, Spain
| | | | | | | |
Collapse
|
13
|
Castro R, Moyano E, Galceran MT. Determination of quaternary ammonium pesticides by liquid chromatography–electrospray tandem mass spectrometry. J Chromatogr A 2001; 914:111-21. [PMID: 11358204 DOI: 10.1016/s0021-9673(01)00523-4] [Citation(s) in RCA: 85] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
A method for the direct determination of paraquat, diquat, chlormequat and difenzoquat in water samples, using an on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry system was developed. No sample preparation was required and the detection limits were below the European Union maximum residue levels. The chromatographic separation was performed using an XTera MS C8 column. The concentration of the ion pair reagent, the pH and the gradient elution were optimized to give high recoveries and good chromatographic resolution between quats. The detection was carried out using an ion trap as mass analyzer. Parameters such as the magnitude and duration of the resonant excitation voltage and the magnitude of the trapping RF voltage for full scan tandem mass spectrometry (MS-MS) experiments were studied to establish the optimal experimental conditions. Moreover, the accurate optimization of these parameters allowed MS-MS experiments of low mass ions, below m/z 200, providing unambiguous peak identification. Finally, the reproducibility of the proposed method was shown by good run-to-run and day-to-day precision values and its applicability to the determination of quats in drinking water was evaluated using spiked samples.
Collapse
Affiliation(s)
- R Castro
- Departamento de Química Analítica, Universidad de Barcelona, Spain
| | | | | |
Collapse
|
14
|
Abstract
In this review, the progress in hyphenation of capillary electrophoresis (CE) with electrospray ionization-mass spectrometry (ESI-MS) since the article of Banks (Banks, J. F., Electrophoresis 1997, 18, 2255-2266) is reported. In all capillary-based electromigration techniques, such as capillary gel electrophoresis (CGE), capillary isotachophoresis (CITP), capillary isoelectric focussing (CIEF), micellar electrokinetic chromatography (MEKC), affinity capillary electrophoresis (ACE), as well as in the hybrid techniques capillary electrochromatography (CEC), and pressurized capillary electrochromatography (pCEC) progress has been made in experimental setups, and for many groups of analytes, such as peptides, proteins, nucleotides, saccharides, drugs and their metabolites, CE/ESI-MS has been successfully applied. Electromigration is further miniaturized. New preconcentration methods allow the investigation of compounds, which are not sensitively detected with ESI-MS. Coordination ion spray (CIS) MS is another method for sensitivity enhancement by on-line formation of charged coordination compounds.
Collapse
Affiliation(s)
- A von Brocke
- University of Tübingen, Institute of Organic Chemistry, Germany
| | | | | |
Collapse
|
15
|
Castro R, Moyano E, Galceran MT. Ion-trap versus quadrupole for analysis of quaternary ammonium herbicides by LC-MS. Chromatographia 2001. [DOI: 10.1007/bf02490423] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
16
|
Affiliation(s)
- S D Richardson
- National Exposure Research Laboratory, U.S. Environmental Protection Agency, Athens, Georgia 30605, USA
| |
Collapse
|
17
|
Affiliation(s)
- S D Richardson
- National Exposure Research Laboratory, U.S. Environmental Protection Agency, Athens, Georgia 30605, USA
| |
Collapse
|
18
|
Lazar AC, Reilly PT, Whitten WB, Ramsey JM. Laser desorption/ionization coupled to tandem mass spectrometry for real-time monitoring of paraquat on the surface of environmental particles. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2000; 14:1523-1529. [PMID: 10931548 DOI: 10.1002/1097-0231(20000830)14:16<1523::aid-rcm58>3.0.co;2-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Aerosol mass spectrometry with laser desorption/ionization was investigated as a possible tool for real-time monitoring of the presence of the pesticide paraquat on the surface of airborne soil particles. Laser desorption/ionization of paraquat dication produced only singly charged ions. The most abundant species were [M](+.), [M - H](+), and [M - CH3](+). Operation of the ion trap mass spectrometer in the MS(3) mode allowed the reduction of the signal dependence on laser fluence fluctuations and permitted the detection of the analyte with good sensitivity and high selectivity. The estimated limit of detection in terms of surface coverage was 0.016 monolayers, approximately 1 attomole of paraquat on the surface of a single micron-sized soil particle.
Collapse
Affiliation(s)
- A C Lazar
- Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831-6142, USA
| | | | | | | |
Collapse
|
19
|
Vreuls RJJ, Dall�ge J, Brinkman UAT. Gas chromatography-time-of-flight mass spectrometry for sensitive determination of organic microcontaminants. ACTA ACUST UNITED AC 1999. [DOI: 10.1002/(sici)1520-667x(199911)11:9<663::aid-mcs4>3.0.co;2-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
20
|
Abstract
The current status of capillary electrophoresis (CE) in pharmaceutical analyses is reviewed with about 300 references, mainly from 1996 until 1999. This article covers the use of CE for assay and purity determination of the main component, analysis of natural medicines, antisense DNA, peptides, and proteins. Analysis of hydrophobic and/or electrically neutral drugs by electrokinetic chromatography, capillary electrochromatography and nonaqueous CE is critically evaluated. Detailed techniques for the separation of enantiomers are given in the text with some actual applications. Furthermore, this review includes sensitivity and regulatory aspects for the actual use of CE in new drug applications (NDA). The analytical validation required for CE in NDA is also treated.
Collapse
Affiliation(s)
- H Nishi
- Analytical Chemistry Department, Tanabe Seiyaku Co., Osaka, Japan.
| |
Collapse
|
21
|
Abstract
Synthetic pesticides are important chemicals since they are widely used to control many types of weeds, insects and other pests in a wide variety of agricultural and nonagricultural settings. This review article is aimed at describing the recent progress made in capillary electrophoresis (CE) and capillary electrochromatography (CEC) of pesticides and their metabolites. The various electrophoretic systems and detection schemes that have been introduced so far for the CE and CEC of pesticides are discussed. Also included in this review article are the various approaches for trace enrichment that are involved in the analysis of dilute pesticide samples.
Collapse
Affiliation(s)
- A Karcher
- Department of Chemistry, Oklahoma State University, Stillwater 74078-3071, USA
| | | |
Collapse
|