1
|
Caslavska J, Mosher RA, Thormann W. Computer simulation of the isotachophoretic migration and separation of norpseudoephedrine stereoisomers with a free or immobilized neutral chiral selector. J Chromatogr A 2020; 1623:461176. [PMID: 32505280 DOI: 10.1016/j.chroma.2020.461176] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 04/24/2020] [Accepted: 04/27/2020] [Indexed: 11/27/2022]
Abstract
A detailed computer simulation study of the isotachophoretic migration and separation of norpseudoephedrine stereoisomers for cases with the neutral selector added to the leader, immobilized to the capillary wall or support, or partially present in the separation column is presented. The electrophoretic transport of the analytes from the sampling compartment into the separation medium with the selector, the formation of a transient mixed zone, the separation dynamics of the stereoisomers with a free or immobilized selector, the dependence of the leader pH, the ionic mobility of norpseudoephedrine, the complexation constant and selector immobilization on steady-state plateau zone properties, and zone changes occurring during the transition from the chiral environment into a selector free leader are thereby visualized in a hitherto unexplored way. For the case with the selector dissolved in the leading electrolyte, simulation data are compared to those observed in experimental setups with coated fused-silica capillaries that feature minimized electroosmosis and zone detection with conductivity and absorbance detectors.
Collapse
Affiliation(s)
- Jitka Caslavska
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | | | - Wolfgang Thormann
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland.
| |
Collapse
|
2
|
Mikkonen S, Caslavska J, Gebauer P, Thormann W. Inverse cationic ITP for separation of methadone enantiomers with sulfated β-cyclodextrin as chiral selector. Electrophoresis 2018; 40:659-667. [PMID: 30311251 DOI: 10.1002/elps.201800387] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 10/03/2018] [Accepted: 10/10/2018] [Indexed: 12/17/2022]
Abstract
Chiral ITP of the weak base methadone using inverse cationic configurations with H+ as leading component and multiple isomer sulfated β-CD (S-β-CD) as leading electrolyte (LE) additive, has been studied utilizing dynamic computer simulation, a calculation model based on steady-state values of the ITP zones, and capillary ITP. By varying the amount of acidic S-β-CD in the LE composed of 3-morpholino-2-hydroxypropanesulfonic acid and the chiral selector, and employing glycylglycine as terminating electrolyte (TE), inverse cationic ITP provides systems in which either both enantiomers, only the enantiomer with weaker complexation, or none of the two enantiomers form cationic ITP zones. For the configuration studied, the data reveal that only S-methadone migrates isotachophoretically when the S-β-CD concentration in the LE is between about 0.484 and 1.113 mM. Under these conditions, R-methadone migrates zone electrophoretically in the TE. An S-β-CD concentration between about 0.070 and 0.484 mM results in both S- and R-methadone forming ITP zones. With >1.113 mM and < about 0.050 mM of S-β-CD in the LE both enantiomers are migrating within the TE and LE, respectively. Chiral inverse cationic ITP with acidic S-β-CD in the LE is demonstrated to permit selective ITP trapping and concentration of the less interacting enantiomer of a weak base.
Collapse
Affiliation(s)
- Saara Mikkonen
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland.,Division of Applied Physical Chemistry, Department of Chemistry, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Jitka Caslavska
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | - Petr Gebauer
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic
| | - Wolfgang Thormann
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| |
Collapse
|
3
|
Caslavska J, Breadmore MC, Thormann W. Dynamic high-resolution computer simulation of isotachophoretic enantiomer separation and zone stability. Electrophoresis 2014; 35:625-37. [DOI: 10.1002/elps.201300438] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Revised: 10/27/2013] [Accepted: 11/02/2013] [Indexed: 11/12/2022]
Affiliation(s)
- Jitka Caslavska
- Clinical Pharmacology Laboratory; Institute for Infectious Diseases; University of Bern; Bern Switzerland
| | - Michael C. Breadmore
- Australian Centre for Research on Separation Science; School of Chemistry; University of Tasmania; Hobart Australia
| | - Wolfgang Thormann
- Clinical Pharmacology Laboratory; Institute for Infectious Diseases; University of Bern; Bern Switzerland
| |
Collapse
|
4
|
Goet G, Baier T, Hardt S, Sen AK. Isotachophoresis with emulsions. BIOMICROFLUIDICS 2013; 7:44103. [PMID: 24404037 PMCID: PMC3732298 DOI: 10.1063/1.4816347] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2013] [Accepted: 07/09/2013] [Indexed: 05/16/2023]
Abstract
An experimental study on isotachophoresis (ITP) in which an emulsion is used as leading electrolyte (LE) is reported. The study aims at giving an overview about the transport and flow phenomena occurring in that context. Generally, it is observed that the oil droplets initially dispersed in the LE are collected at the ITP transition zone and advected along with it. The detailed behavior at the transition zone depends on whether or not surfactants (polyvinylpyrrolidon, PVP) are added to the electrolytes. In a system without surfactants, coalescence is observed between the droplets collected at the ITP transition zone. After having achieved a certain size, the droplets merge with the channel walls, leaving an oil film behind. In systems with PVP, coalescence is largely suppressed and no merging of droplets with the channel walls is observed. Instead, at the ITP transition zone, a droplet agglomerate of increasing size is formed. In the initial stages of the ITP experiments, two counter rotating vortices are formed inside the terminating electrolyte. The vortex formation is qualitatively explained based on a hydrodynamic instability triggered by fluctuations of the number density of oil droplets.
Collapse
Affiliation(s)
- G Goet
- Institute for Nano- and Microfluidics, Center of Smart Interfaces, TU Darmstadt, 64287 Darmstadt, Germany
| | - T Baier
- Institute for Nano- and Microfluidics, Center of Smart Interfaces, TU Darmstadt, 64287 Darmstadt, Germany
| | - S Hardt
- Institute for Nano- and Microfluidics, Center of Smart Interfaces, TU Darmstadt, 64287 Darmstadt, Germany
| | - A K Sen
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai 600036, India
| |
Collapse
|
5
|
Smejkal P, Bottenus D, Breadmore MC, Guijt RM, Ivory CF, Foret F, Macka M. Microfluidic isotachophoresis: A review. Electrophoresis 2013; 34:1493-509. [DOI: 10.1002/elps.201300021] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Revised: 03/06/2013] [Accepted: 03/07/2013] [Indexed: 12/22/2022]
Affiliation(s)
- Petr Smejkal
- ACROSS and School of Chemistry; University of Tasmania; Hobart; Australia
| | - Danny Bottenus
- Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; WA; USA
| | | | - Rosanne M. Guijt
- ACROSS and School of Pharmacy; University of Tasmania; Hobart; Australia
| | - Cornelius F. Ivory
- Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; WA; USA
| | - František Foret
- Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic; v.v.i., Brno; Czech Republic
| | - Mirek Macka
- ACROSS and School of Chemistry; University of Tasmania; Hobart; Australia
| |
Collapse
|
6
|
Ríos Á, Ríos Á, Zougagh M, Zougagh M. Sample preparation for micro total analytical systems (μ-TASs). Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2012.12.009] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
7
|
Some theoretical and practical aspects in the separation of humic substances by combined liquid chromatography methods. J Chromatogr A 2011; 1218:8946-57. [PMID: 21788022 DOI: 10.1016/j.chroma.2011.06.107] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2011] [Revised: 06/27/2011] [Accepted: 06/28/2011] [Indexed: 11/24/2022]
Abstract
Permanent need to understand nature, structure and properties of humic substances influences also separation methods that are in a wide scope used for fractionation, characterization and analysis of humic substances (HS). At the first glance techniques based on size-exclusion phenomena are the most useful and utilized for relating elution data to the molecular mass distribution of HS, however, with some limitations and exceptions, respectively, in the structural investigation of HS. The second most abundant separation mechanism is reversed-phase based on weak hydrophobic interactions beneficially combined with the step gradients inducing distinct features in rather featureless analytical signal of HS. Relatively great effort is invested to the developments of immobilized-metal affinity chromatography mimicking chelate-forming properties of HS as ligands in the environment. Surprisingly, relatively less attention is given to the ion-ion interactions based ion-exchange chromatography of HS. Chromatographic separation methods play also an important role in the examination of interactions of HS with pesticides. They allow us to determine binding constants and the other data necessary to predict the mobility of chemical pollutants in the environment. HS is frequently adversely acting in analytical procedures as interfering substance, so more detailed information is desired on manifestation of its numerous properties in analytical procedures. The article topic is covered by the review emphasizing advances in the field done in the period of last 10 years from 2000 till 2010.
Collapse
|
8
|
Marák J, Staňová A, Gajdoštínová S, Škultéty L, Kaniansky D. Some possibilities of an analysis of complex samples by a mass spectrometry with a sample pretreatment by an offline coupled preparative capillary isotachophoresis. Electrophoresis 2011; 32:1273-81. [DOI: 10.1002/elps.201000629] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2010] [Revised: 01/10/2011] [Accepted: 01/20/2011] [Indexed: 01/30/2023]
|
9
|
Tomás R, Klepárník K, Foret F. Multidimensional liquid phase separations for mass spectrometry. J Sep Sci 2008; 31:1964-79. [PMID: 18615817 DOI: 10.1002/jssc.200800113] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Large part of the current research in biology, medicine, and biotechnology depends on the analysis of DNA (genomics), proteins (proteomics), or metabolites (metabolomics). The advances in biotechnology also command development of adequate analytical instrumentation capable to analyze minute amounts of samples. The analysis of the content of single cells may serve as an example of ultimate analytical applications. Most of the separation techniques have been developed in the last three decades and alternative approaches are being investigated. At present, the main protocols for analyses of complex mixtures include 2-DE (IEF) followed by electrophoresis in SDS polyacrylamide gel (SDS-PAGE) and chromatographic techniques. Information-rich techniques such as MS and NMR are essential for the identification and structure analysis of the analyzed compounds. High resolution separation of the individual sample components is often a prerequisite for success. High resolution proteomic analysis in the majority of laboratories still relies on the time consuming and laborious offline methods. This review highlights some of the important aspects of 2-D separations including microfluidics.
Collapse
Affiliation(s)
- Roman Tomás
- Institute of Analytical Chemistry, Brno, Czech Republic
| | | | | |
Collapse
|
10
|
Chankvetadze B. Enantioseparations by using capillary electrophoretic techniques. The story of 20 and a few more years. J Chromatogr A 2007; 1168:45-70; discussion 44. [PMID: 17765908 DOI: 10.1016/j.chroma.2007.08.008] [Citation(s) in RCA: 203] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2007] [Revised: 07/27/2007] [Accepted: 08/02/2007] [Indexed: 11/29/2022]
Abstract
This paper provides the author's insight on the past, present and future of performing enantioseparations using capillary electrophoretic (CE) techniques. These techniques are discussed from the historical point of view, as well as based on their potential as the separation techniques of today and the future. The overview covers mechanistic as well as practical aspects of CE techniques.
Collapse
Affiliation(s)
- Bezhan Chankvetadze
- Institute of Chemistry, School of Exact and Natural Sciences and Molecular Recognition and Separation Science Laboratory, Tbilisi State University, Chavchavadze Ave. 1, 0128 Tbilisi, Georgia.
| |
Collapse
|
11
|
Shadpour H, Hupert ML, Patterson D, Liu C, Galloway M, Stryjewski W, Goettert J, Soper SA. Multichannel microchip electrophoresis device fabricated in polycarbonate with an integrated contact conductivity sensor array. Anal Chem 2007; 79:870-8. [PMID: 17263312 DOI: 10.1021/ac0612168] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A 16-channel microfluidic chip with an integrated contact conductivity sensor array is presented. The microfluidic network consisted of 16 separation channels that were hot-embossed into polycarbonate (PC) using a high-precision micromilled metal master. All channels were 40 microm deep and 60 microm wide with an effective separation length of 40 mm. A gold (Au) sensor array was lithographically patterned onto a PC cover plate and assembled to the fluidic chip via thermal bonding in such a way that a pair of Au microelectrodes (60 microm wide with a 5 microm spacing) was incorporated into each of the 16 channels and served as independent contact conductivity detectors. The spacing between the corresponding fluidic reservoirs for each separation channel was set to 9 mm, which allowed for loading samples and buffers to all 40 reservoirs situated on the microchip in only five pipetting steps using an 8-channel pipettor. A printed circuit board (PCB) with platinum (Pt) wires was used to distribute the electrophoresis high-voltage to all reservoirs situated on the fluidic chip. Another PCB was used for collecting the conductivity signals from the patterned Au microelectrodes. The device performance was evaluated using microchip capillary zone electrophoresis (mu-CZE) of amino acid, peptide, and protein mixtures as well as oligonucleotides that were separated via microchip capillary electrochromatography (mu-CEC). The separations were performed with an electric field (E) of 90 V/cm and were completed in less than 4 min in all cases. The conductivity detection was carried out using a bipolar pulse voltage waveform with a pulse amplitude of +/-0.6 V and a frequency of 6.0 kHz. The conductivity sensor array concentration limit of detection (SNR = 3) was determined to be 7.1 microM for alanine. The separation efficiency was found to be 6.4 x 10(4), 2.0 x 10(3), 4.8 x 10(3), and 3.4 x 10(2) plates for the mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins, respectively, with an average channel-to-channel migration time reproducibility of 2.8%. The average resolution obtained for mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins was 4.6, 1.0, 0.9, and 1.0, respectively. To the best of our knowledge, this report is the first to describe a multichannel microchip electrophoresis device with integrated contact conductivity sensor array.
Collapse
Affiliation(s)
- Hamed Shadpour
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, USA
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Vlčková M, Stettler AR, Schwarz MA. Microchip Affinity Capillary Electrophoresis: Applications and Recent Advances. J LIQ CHROMATOGR R T 2007. [DOI: 10.1080/10826070600574754] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Markéta Vlčková
- a Universität Basel, Departement Chemie , Basel, Switzerland
| | | | | |
Collapse
|
13
|
Weng X, Bi H, Liu B, Kong J. On-chip chiral separation based on bovine serum albumin-conjugated carbon nanotubes as stationary phase in a microchannel. Electrophoresis 2006; 27:3129-35. [PMID: 16807934 DOI: 10.1002/elps.200500840] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A novel method of chiral separation based on protein-stationary phase immobilized in a poly(methyl methacrylate) microfluidic chip was developed. BSA conjugated with the shortened carboxylic single-walled carbon nanotubes (SWNTs) was employed as the chiral selector. Successful separation of tryptophan enantiomers was achieved in less than 70 s with a resolution factor of 1.35 utilizing a separation length of 32 mm. This is the first example of chiral separation based on SWNTs-BSA conjugates as stationary phase immobilized in microchip channel. The stability of the stationary phase in the channel was examined by microchip electrophoresis with laser-induced fluorescence detection. Factors that influenced the chiral separation resolution were examined. Under the optimized conditions, the proposed modified chip revealed adequate repeatability concerning run-to-run. These results show that the use of SWNTs-BSA conjugates within microfluidic channels hold great promise for a variety of analytical schemes.
Collapse
Affiliation(s)
- Xuexiang Weng
- Department of Chemistry, Fudan University, Shanghai 200433, P. R. China
| | | | | | | |
Collapse
|
14
|
Gübitz G, Schmid MG. Chiral separation principles in chromatographic and electromigration techniques. Mol Biotechnol 2006; 32:159-80. [PMID: 16444017 DOI: 10.1385/mb:32:2:159] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Almost half of the drugs in use today are chiral. It is well established that the pharmacological activity is mostly restricted to one of the enantiomers (eutomer). There can be qualitative and quantitative differences in the activity of the enantiomers. In many cases, the inactive enantiomer (distomer) shows unwanted side effects or even toxic effects. Even if the side effects are not that drastic, the distomer has to be metabolized and this represents an unnecessary burden for the organism. Therefore, the development of methods for the separation of enantiomers, both on analytical and preparative scale, has become increasingly important. Chromatographic techniques such as thin layer chromatography (TLC), gas chromatography (GC), supercritical fluid chromatography (SFC), and above all high-performance liquid chromatography (HPLC) have been used for enantiomer separation for about two decades. More recently, electromigration techniques, such as capillary electrophoresis and capillary electrochromatography, have been shown to be powerful alternatives to chromatographic methods. This review gives a short overview of different chiral separation principles and their application. Several new developments are discussed.
Collapse
Affiliation(s)
- Gerald Gübitz
- Institute of Pharmaceutical Sciences, Department of Pharmaceutical Chemistry, Karl-Franzens University, Universitätsplatz 1, A-8010 Graz, Austria
| | | |
Collapse
|
15
|
Silvertand LHH, Machtejevas E, Hendriks R, Unger KK, van Bennekom WP, de Jong GJ. Selective protein removal and desalting using microchip CE. J Chromatogr B Analyt Technol Biomed Life Sci 2006; 839:68-73. [PMID: 16600700 DOI: 10.1016/j.jchromb.2006.03.036] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2005] [Revised: 03/03/2006] [Accepted: 03/15/2006] [Indexed: 11/20/2022]
Abstract
This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sample preconcentration and sample clean-up, while in the second channel the selected compounds are separated. Isotachophoresis (ITP) combined with zone electrophoresis (CZE) was used to preconcentrate a myoglobin sample by a factor of about 65 before injection into the second dimension and to desalt a mixture of six proteins with 100 mM NaCl. However, ITP-CZE could not be used for the removal of two proteins from a protein/peptide sample since the protein zone in the ITP step was too small to remove certain compounds. Therefore, we used CZE-CZE for the removal of proteins from a protein/peptide mixture, thereby injecting only the peptides into the second CZE separation channel.
Collapse
Affiliation(s)
- L H H Silvertand
- Department of Biomedical Analysis, Faculty of Pharmaceutical Sciences, Utrecht University, P.O. Box 80082, 3508 TB Utrecht, The Netherlands.
| | | | | | | | | | | |
Collapse
|
16
|
Belder D, Ludwig M, Wang LW, Reetz MT. Enantioselektive Katalyse und Analyse auf einem Mikrochip. Angew Chem Int Ed Engl 2006. [DOI: 10.1002/ange.200504205] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
17
|
Belder D, Ludwig M, Wang LW, Reetz MT. Enantioselective Catalysis and Analysis on a Chip. Angew Chem Int Ed Engl 2006; 45:2463-6. [PMID: 16440384 DOI: 10.1002/anie.200504205] [Citation(s) in RCA: 118] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Detlev Belder
- Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, 45470 Mülheim an der Ruhr, Germany.
| | | | | | | |
Collapse
|
18
|
Chen L, Prest JE, Fielden PR, Goddard NJ, Manz A, Day PJR. Miniaturised isotachophoresis analysis. LAB ON A CHIP 2006; 6:474-87. [PMID: 16572209 DOI: 10.1039/b515551g] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The application of miniaturized total analysis systems (microTAS) has seen rapid development over the past few years. Isotachophoresis (ITP) has been transferred into microchip format for both electrophoretic separation and pretreatment purposes, due to its advantageous features including separation parameters controlled by electrolyte composition and high sample load capacity. The primary focus of this concise review is to summarize the basic features of microchip based ITP and its applications to the analysis and pretreatment of ionic compounds and biomolecules that have arisen since 1998.
Collapse
Affiliation(s)
- Lin Chen
- Institute for Analytical Sciences, Bunsen-Kirchhoff Str. 11, D-44139 Dortmund, Germany
| | | | | | | | | | | |
Collapse
|
19
|
Ro KW, Hahn JH. Precolumn diastereomerization and micellar electrokinetic chromatography on a plastic microchip: rapid chiral analysis of amino acids. Electrophoresis 2006; 26:4767-73. [PMID: 16278921 DOI: 10.1002/elps.200500370] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Precolumn derivatization and chiral separation of DL-amino acids based on diastereomerization have been performed on an integrated poly(dimethylsiloxane) microchip. Diastereomeric derivatives were formed in a microfabricated precolumn reactor by the reaction of amino acid enantiomers with o-phthaldialdehyde/2,3,4,6-tetra-O-acetyl-1-thio-beta-D-glucopyranose (OPA/TATG), and separated by MEKC in an achiral environment without chiral selectors in the running buffer. Optimized precolumn reactions and chiral separations of amino acids were achieved within 2.5 min. Resolutions of diastereomers of OPA/TATG-amino acids were in the range of 2.5-6.1 at optimized separation conditions. Simultaneous separation of a mixture of five chiral amino acids was successfully performed in a single run in less than 100 s.
Collapse
Affiliation(s)
- Kyung Won Ro
- Department of Chemistry, Division of Molecular and Life Science, Pohang University of Science and Technology, South Korea
| | | |
Collapse
|
20
|
Gübitz G, Schmid MG. Recent advances in chiral separation principles in capillary electrophoresis and capillary electrochromatography. Electrophoresis 2005; 25:3981-96. [PMID: 15597419 DOI: 10.1002/elps.200406173] [Citation(s) in RCA: 109] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This review summarizes recent developments in chiral separation in capillary zone electrophoresis (CZE), electrokinetic chromatography (EKC), and capillary electrochromatography (CEC) covering literature published since the year 2000. New chiral selectors and innovative approaches for CE and CEC are introduced. Recent progress in column technology for CEC is highlighted and the development of new chiral stationary phases is discussed. This review is not dedicated to list applications but will focus on new developments.
Collapse
Affiliation(s)
- Gerald Gübitz
- Institute of Pharmaceutical Sciences, Dept. of Pharm. Chemistry, Karl-Franzens-University, Graz, Austria.
| | | |
Collapse
|
21
|
Masár M, Danková M, Olvecká E, Stachurová A, Kaniansky D, Stanislawski B. Determination of free sulfite in wine by zone electrophoresis with isotachophoresis sample pretreatment on a column-coupling chip. J Chromatogr A 2004; 1026:31-9. [PMID: 14763730 DOI: 10.1016/j.chroma.2003.11.038] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
This work deals with the determination of free sulfite in wine by zone electrophoresis (ZE) with on-line isotachophoresis (ITP) sample pretreatment on a column-coupling (CC) chip with conductivity detection. A rapid pre-column conversion of sulfite to hydroxymethanesulfonate (HMS), to minimize oxidation losses of the analyte, was included into the developed analytical procedure, while ITP and ZE were responsible for specific analytical tasks in the separations performed on the CC chip. ITP, for example, eliminated the sample matrix from the separation compartment and, at the same time, provided a selective concentration of HMS before its transfer to the ZE stage of the separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions favoring a sensitive conductivity detection of HMS. In this way, ITP and ZE cooperatively contributed to a 900 microg/l concentration detectability for sulfite as attained for a 60 nl load of wine (a 15-fold wine dilution and the use of a 0.9 microl sample injection channel of the chip) and, consequently, to the determination of free sulfite when this was present in wine at the concentrations as low as 3 mg/l. The separations were carried out in a closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, made a frame for precise migration and quantitation data as achieved for HMS in both the model and wine samples. Ninety percent recoveries, as typically obtained for free sulfite in wine samples, indicate promising potentialities of the present method as far as the accuracies of the provided analytical results are concerned.
Collapse
Affiliation(s)
- Marián Masár
- Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University, Mlynská Dolina CH-2, SK-84215 Bratislava, Slovak Republic
| | | | | | | | | | | |
Collapse
|
22
|
Guijt RM, Evenhuis CJ, Macka M, Haddad PR. Conductivity detection for conventional and miniaturised capillary electrophoresis systems. Electrophoresis 2004; 25:4032-57. [PMID: 15597418 DOI: 10.1002/elps.200406156] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Since the introduction of capillary electrophoresis (CE), conductivity detection has been an attractive means of detection. No additional chemical properties are required for detection, and no loss in sensitivity is expected when miniaturising the detector to scale with narrow-bore capillaries or even to the microchip format. Integration of conductivity and CE, however, involves a challenging combination of engineering issues. In conductivity detection the resistance of the solution is most frequently measured in an alternating current (AC) circuit. The influence of capacitors both in series and in parallel with the solution resistance should be minimised during conductivity measurements. For contact conductivity measurements, the positioning and alignment of the detection electrodes is crucial. A contact conductivity detector for CE has been commercially available, but was withdrawn from the market. Microfabrication technology enables integration and precise alignment of electrodes, resulting in the popularity of conductivity detection in microfluidic devices. In contactless conductivity detection, the alignment of the electrodes with respect to the capillary is less crucial. Contactless conductivity detection (CCD) was introduced in capillary CE, and similar electronics have been applied for CCD using planar electrodes in microfluidic devices. A contactless conductivity detector for capillaries has been commercialised recently. In this review, different approaches towards conductivity detection in capillaries and chip-based CE are discussed. In contrast to previous reviews, the focus of the present review is on the technological developments and challenges in conductivity detection in CE.
Collapse
Affiliation(s)
- Rosanne M Guijt
- Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, School of Chemistry, Hobart, TAS, Australia
| | | | | | | |
Collapse
|
23
|
Abstract
Fast chiral separation of DNS-amino acids could be realized using microchip electrophoresis with fluorescence detection. For this purpose, highly sulfated cyclodextrins (HS-gamma-CD) were used as chiral selectors enabling high selectivity. Even subsecond separation of DNS-tryptophan, DNS-norleucine, DNS-phenylalanine, DNS-methionine, and DNS-aspartic acid could be achieved. Baseline separation could be accomplished within 720 ms, which is the fastest separation of enantiomers reported to date. A more complex mixture consisting of three chiral DNS-amino acids could be separated within 3.3 s utilizing a separation length of only 7 mm and an electrical field strength of 2012 V/cm.
Collapse
Affiliation(s)
- Natalia Piehl
- Abteilung für Chromatographie, Max-Planck-Institut für Kohlenforschung, Mülheim an der Ruhr, Germany
| | | | | |
Collapse
|
24
|
Prest JE, Baldock SJ, Fielden PR, Goddard NJ, Brown BJT. Analysis of amino acids by miniaturised isotachophoresis. J Chromatogr A 2004; 1051:221-6. [PMID: 15532577 DOI: 10.1016/j.chroma.2004.05.026] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A method allowing the miniaturised isotachophoretic analysis of amino acids has been developed. To overcome the problems of carbonate contamination which occur when performing separations at alkaline pH levels glycolate was used as the leading ion. Addition of magnesium to the leading electrolyte as a counter species was found to improve the separations. The method has been used on a poly(methyl methacrylate) microdevice with integrated on-column conductivity detectors. The behaviour of a range of common amino acids was investigated and successful separations of up to seven amino acids were made. Good linearity was observed with calibration curves for aspartic acid and phenylalanine over the range 0.063-1.0 mM. Limits of detection for these two species were calculated to be 0.060 and 0.018 mM, respectively.
Collapse
Affiliation(s)
- Jeff E Prest
- Department of Instrumentation and Analytical Science, UMIST P.O. Box 88, Manchester, UK.
| | | | | | | | | |
Collapse
|
25
|
Baldock SJ, Fielden PR, Goddard NJ, Kretschmer HR, Prest JE, Treves Brown BJ. Novel variable volume injector for performing sample introduction in a miniaturised isotachophoresis device. J Chromatogr A 2004; 1042:181-8. [PMID: 15296404 DOI: 10.1016/j.chroma.2004.05.062] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
A microdevice design furnished with a novel sample injector, capable of delivering variable volume samples, for miniaturised isotachophoretic separations is presented. Micromachining by direct milling was used to realise two flow channel network designs on poly(methyl methacrylate) chips. Both designs comprised a wide bore sample channel interfaced, via a short connection channel, to a narrow bore separation channel. Superior injection performance was observed with a connection channel angled at 45 degrees to the separation channel compared to a device using a channel angled at 90 degrees. Automated delivery of electrolytes to the microdevice was demonstrated with both hydrostatic pumping and syringe pumps; both gave reproducible sample injection. A range of different sampling strategies were investigated. Isotachophoretic separations of model analytes (metal ions and an anionic dye) demonstrated the potential of the device. Separations of ten metal cations were achieved in under 475 s.
Collapse
Affiliation(s)
- S J Baldock
- Department of Instrumentation and Analytical Science, UMIST, PO Box 88, Manchester M60 1QD, UK.
| | | | | | | | | | | |
Collapse
|
26
|
Kaniansky D, Masár M, Bodor R, Zúborová M, Olvecká E, Jöhnck M, Stanislawski B. Electrophoretic separations on chips with hydrodynamically closed separation systems. Electrophoresis 2003; 24:2208-2227. [PMID: 12858394 DOI: 10.1002/elps.200305474] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This review focuses on capillary electrophoretic separations performed on capillary electrophoresis chips (CE chips) with hydrodynamically closed separation systems in a context with transport processes (electroosmotic flow (EOF)) and hydrodynamic flow (HDF)) that may accompany the separations in these devices. It also reflects some relevant works dealing with conventional CE operating under such hydrodynamic conditions. The use of zone electrophoresis (ZE), isotachophoresis (ITP) and their on-line combination (ITP-ZE) on the single-column and column-coupling CE chips with the closed separation systems and related problems are key topics of the review. Some attention is paid to sample pretreatment in the separations performed on the CE chips. Here, mainly potentialities of the ITP-ZE combination in trace analysis applications of the miniaturized systems are discussed in a broader extent. Links between the ZE separation and detection provide a frame for the discussion of current status of the detection on the CE chips. Analytical applications illustrate potentialities of the CE chips operating with the closed separation systems (suppressed HDF and EOF) to the determination of small ions present in various matrices by ZE, ITP and ITP-ZE.
Collapse
Affiliation(s)
- Dusan Kaniansky
- Department of Analytical Chemistry, Faculty of Science, Comenius University, Bratislava, Slovakia.
| | | | | | | | | | | | | |
Collapse
|
27
|
Baldock SJ, Fielden PR, Goddard NJ, Prest JE, Treves Brown BJ. Integrated moulded polymer electrodes for performing conductivity detection on isotachophoresis microdevices. J Chromatogr A 2003; 990:11-22. [PMID: 12685579 DOI: 10.1016/s0021-9673(02)01967-2] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The feasibility of using integrated injection moulded polymer electrodes as drive and detection electrodes for performing miniaturised isotachophoresis (ITP) separations with conductivity detection has been demonstrated. Injection moulded electrodes were produced from three different grades of carbon-filled polymer. Two of the electrode designs were found to be suitable for performing on-chip conductivity detection. The high-voltage characteristics of the microdevices were found to be suitable for performing ITP, with a power dissipation up to 1.4 W m(-1) being achieved. Three model separations are presented to demonstrate the separation capability of the miniaturised injection moulded devices. Three anionic dyes, two inorganic anions and a mixture of eight alkaline earth, transition and lanthanide metal cations were analysed.
Collapse
Affiliation(s)
- S J Baldock
- Department of Instrumentation and Analytical Science, UMIST, P.O. Box 88, Manchester M60 1QD, UK.
| | | | | | | | | |
Collapse
|
28
|
Zúborová M, Demianová Z, Kaniansky D, Masár M, Stanislawski B. Zone electrophoresis of proteins on a poly(methyl methacrylate) chip with conductivity detection. J Chromatogr A 2003; 990:179-88. [PMID: 12685596 DOI: 10.1016/s0021-9673(02)01805-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
This work deals with zone electrophoresis (ZE) separations of proteins on a poly(methyl methacrylate) chip with integrated conductivity detection. Experiments were performed in the cationic mode of the separation (pH 2.9) with a hydrodynamically closed separation compartment and suppressed electroosmotic flow. The test proteins reached the detector in less than 10 min under these working conditions and their migration times characterized excellent repeatabilities (0.1-0.6% RSD values). The chip-to-chip agreements of the migration times, evaluated from the ZE runs performed on three chips, were within 1.5%. The conductivity detection provided for protein, loaded on the chip at 10-1000 microg/ml concentrations, detection responses were characterized by 1-5% RSD values of their peak areas. Such migration and detection performances made a frame for reproducible baseline separations of a five-constituent mixture (cytochrome c, avidin, conalbumin, human hemoglobin and trypsin inhibitor). On the other hand, a high sample injection channel/separation compartment volume ratio of the chip (500 nl/8500 nl) restricted the resolution of proteins of very close effective mobilities in spite of the fact that in the initial phase of the separation an electric field stacking was applied. A maximum macroconstituent/trace constituent ratio attainable for proteins on the chip was assessed for cytochrome c (quantifiable when its concentration in the loaded sample was 10 microg/ml) and apo-transferrin (containing a trace constituent migrating in the position of cytochrome c detectable when the load of apo-transferrin was 2000 microg/ml). This assessment indicated that a ratio of 1000:1 is attainable with the aid of conductivity detection on the present chip.
Collapse
Affiliation(s)
- Mária Zúborová
- Department of Analytical Chemistry, Faculty of Science, Comenius University, Mlynská Dolina CH-2, SK-84215 Bratislava, Slovak Republic
| | | | | | | | | |
Collapse
|
29
|
de Mello AJ, Beard N. Dealing with real samples: sample pre-treatment in microfluidic systems. LAB ON A CHIP 2003; 3:11N-19N. [PMID: 15106602 DOI: 10.1039/b301019h] [Citation(s) in RCA: 108] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
|
30
|
Bodor R, Žúborová M, Ölvecká E, Madajová V, Masár M, Kaniansky D, Stanislawski B. Isotachophoresis and isotachophoresis-zone electrophoresis of food additives on a chip with column-coupling separation channels. J Sep Sci 2001. [DOI: 10.1002/1615-9314(20010901)24:9<802::aid-jssc802>3.0.co;2-1] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|