1
|
Zeptomole detection of DNA based on microparticle dissociation from a glass plate in a combined acoustic-gravitational field. Talanta 2022; 238:123042. [PMID: 34801899 DOI: 10.1016/j.talanta.2021.123042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 11/01/2021] [Accepted: 11/05/2021] [Indexed: 11/23/2022]
Abstract
In this study, we propose a novel detection principle based on the dissociation of microparticles immobilized on a glass plate through weak hybridization involving 4-6 base pairs (bps) in a combined acoustic-gravitational field. Particle dissociation from the glass plate occurs when the resultant of the acoustic radiation force (Fac) and the sedimentation force (Fsed) exerted on the particle exceeds the binding force owing to the weak hybridization (Fbind). Because Fac and Fsed can be controlled by the microparticle density, and Fac is a function of the applied voltage to the transducer (V), an increase in V induces particle dissociation. The binding of gold nanoparticles (AuNPs) onto silica microparticles (SPs) resulting from the strong hybridization of 20 bps induces an increase in the density of SPs, leading to an increase in Fac and Fsed; consequently, the voltage V required for dissociation becomes lower than that required without AuNP binding. We demonstrate that the dependence of the binding number of AuNPs per SP on V follows the theoretical prediction. The binding of 7500 AuNPs per SP can be detected as a 10 V change in V. The present approach allows the detection of 2000 DNA molecules involved in the strong hybridization between AuNPs and SP.
Collapse
|
2
|
van Leerdam JA, Vervoort J, Stroomberg G, de Voogt P. Identification of unknown microcontaminants in Dutch river water by liquid chromatography-high resolution mass spectrometry and nuclear magnetic resonance spectroscopy. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:12791-12799. [PMID: 25296128 DOI: 10.1021/es502765e] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In the past decade during automated surface water monitoring in the river Meuse at border station Eijsden in The Netherlands, a set of unknown compounds were repeatedly detected by online liquid chromatography-diode-array detection in a relatively high signal intensity. Because of the unknown nature of the compounds, the consequently unknown fate of this mixture in water treatment processes, the location being close to the water inlet of a drinking water supply company and their possible adverse public health effects, it was deemed necessary to elucidate the identity of the compounds. No data are available for the occurrence of these unknowns at downstream locations. After concentration and fractionation of a sample by preparative Liquid Chromatography, identification experiments were performed using Liquid Chromatography-High Resolution Mass Spectrometry (LC-HR-MS) combined with High Resolution Nuclear Magnetic Resonance Spectroscopy (HR-NMR). Accurate mass determination of the unknown parent compound and its fragments obtained in MS/MS provided relevant information on the elemental composition of the unknown compounds. With the use of NMR techniques and the information about the elemental composition, the identity of the compounds in the different sample fractions was determined. Beside some regularly detected compounds in surface water, like caffeine and bisphenol-S, five dihydroxydiphenylmethane isomers were identified. The major unknown compound was identified as 4,4'-dihydroxy-3,5,3',5'-tetra(hydroxymethyl)diphenylmethane. This compound was confirmed by analysis of the pure reference compound. This is one of the first studies that employs the combination of high resolution MS with NMR for identification of truly unknown compounds in surface waters at the μg/L level. Five of the seven identified compounds are unexpected and not contained in the CAS database, while they can be presumed to be products generated during the production of resins.
Collapse
Affiliation(s)
- J A van Leerdam
- KWR, Watercycle Research Institute , P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands
| | | | | | | |
Collapse
|
3
|
Gao J, Borton DJ, Owen BC, Jin Z, Hurt M, Amundson LM, Madden JT, Qian K, Kenttämaa HI. Laser-induced acoustic desorption/atmospheric pressure chemical ionization mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2011; 22:531-8. [PMID: 21472571 PMCID: PMC3073421 DOI: 10.1007/s13361-010-0048-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2010] [Revised: 12/09/2010] [Accepted: 12/09/2010] [Indexed: 05/30/2023]
Abstract
Laser-induced acoustic desorption (LIAD) was successfully coupled to a conventional atmospheric pressure chemical ionization (APCI) source in a commercial linear quadrupole ion trap mass spectrometer (LQIT). Model compounds representing a wide variety of different types, including basic nitrogen and oxygen compounds, aromatic and aliphatic compounds, as well as unsaturated and saturated hydrocarbons, were tested separately and as a mixture. These model compounds were successfully evaporated into the gas phase by using LIAD and then ionized by using APCI with different reagents. From the four APCI reagent systems tested, neat carbon disulfide provided the best results. The mixture of methanol and water produced primarily protonated molecules, as expected. However, only the most basic compounds yielded ions under these conditions. In sharp contrast, using APCI with either neat benzene or neat carbon disulfide as the reagent resulted in the ionization of all the analytes studied to predominantly yield stable molecular ions. Benzene yielded a larger fraction of protonated molecules than carbon disulfide, which is a disadvantage. A similar but minor amount of fragmentation was observed for these two reagents. When the experiment was performed without a liquid reagent (nitrogen gas was the reagent), more fragmentation was observed. Analysis of a known mixture as well as a petroleum cut was also carried out. In summary, the new experiment presented here allows the evaporation of thermally labile compounds, both polar and nonpolar, without dissociation or aggregation, and their ionization to predominantly form stable molecular ions.
Collapse
Affiliation(s)
- Jinshan Gao
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907
| | - David J. Borton
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907
| | - Benjamin C. Owen
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907
| | - Zhicheng Jin
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907
| | - Matt Hurt
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907
| | - Lucas M. Amundson
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907
| | - Jeremy T. Madden
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907
| | - Kuangnan Qian
- ExxonMobil Research and Engineering Company, 1545 Route 22 East, Annandale, New Jersey 08801
| | - Hilkka I. Kenttämaa
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907
| |
Collapse
|
4
|
Electrochemically modulated liquid chromatographic separation of triazines and the effect of pH on retention. J Chromatogr A 2010; 1217:4395-401. [DOI: 10.1016/j.chroma.2010.04.031] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2009] [Revised: 04/05/2010] [Accepted: 04/12/2010] [Indexed: 11/23/2022]
|
5
|
Park S, Lee SJ, Kim HG, Jeong WY, Shim JH, Abd El-Aty AM, Jeong SW, Lee WS, Kim ST, Shin SC. Residue analysis of multi-class pesticides in watermelon by LC-MS/MS. J Sep Sci 2010; 33:493-501. [DOI: 10.1002/jssc.200900644] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
6
|
Niessen WMA. Group-specific fragmentation of pesticides and related compounds in liquid chromatography-tandem mass spectrometry. J Chromatogr A 2009; 1217:4061-70. [PMID: 19815223 DOI: 10.1016/j.chroma.2009.09.058] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2009] [Revised: 09/10/2009] [Accepted: 09/23/2009] [Indexed: 11/17/2022]
Abstract
Current strategies in the LC-MS analysis of pesticides and related compounds in environmental samples, fruits and vegetables, and biological samples mostly rely on the selection of appropriate precursor/product-ion combinations (transitions) for selected reaction monitoring (SRM), often based on automated parameter optimization and selection of the transition. Such a procedure does not require any information on the type of fragmentation reaction involved in the generation of the product ion from the selected precursor ion. However, such information does become important in untargeted screening for unknown contaminants in environmental and food samples, which are generally based on a combination of high-resolution mass spectrometry and (multistage) tandem mass spectrometry. With this in mind, the group-specific fragmentation behaviour has been studied for six classes of pesticides and herbicides, i.e., triazines, organophosphorous pesticides, phenylurea herbicides, carbamates, sulfonylurea herbicides, and chlorinated phenoxy acid herbicides. When relevant, some comparison was made between fragmentation of protonated molecules in MS-MS and of molecular ions generated by electron ionization in GC-MS.
Collapse
Affiliation(s)
- W M A Niessen
- hyphen MassSpec, de Wetstraat 8, 2332 XT Leiden, The Netherlands.
| |
Collapse
|
7
|
Famiglini G, Palma P, Termopoli V, Trufelli H, Cappiello A. Single-Step LC/MS Method for the Simultaneous Determination of GC-Amenable Organochlorine and LC-Amenable Phenoxy Acidic Pesticides. Anal Chem 2009; 81:7373-8. [DOI: 10.1021/ac9008995] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- G. Famiglini
- Dipartimento di Scienze Geologiche, Tecnologie Chimiche e Ambientali, Università degli Studi di Urbino “Carlo Bo”, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - P. Palma
- Dipartimento di Scienze Geologiche, Tecnologie Chimiche e Ambientali, Università degli Studi di Urbino “Carlo Bo”, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - V. Termopoli
- Dipartimento di Scienze Geologiche, Tecnologie Chimiche e Ambientali, Università degli Studi di Urbino “Carlo Bo”, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - H. Trufelli
- Dipartimento di Scienze Geologiche, Tecnologie Chimiche e Ambientali, Università degli Studi di Urbino “Carlo Bo”, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - A. Cappiello
- Dipartimento di Scienze Geologiche, Tecnologie Chimiche e Ambientali, Università degli Studi di Urbino “Carlo Bo”, Piazza Rinascimento 6, 61029 Urbino, Italy
| |
Collapse
|
8
|
Kuster M, López de Alda M, Barceló D. Liquid chromatography–tandem mass spectrometric analysis and regulatory issues of polar pesticides in natural and treated waters. J Chromatogr A 2009; 1216:520-9. [DOI: 10.1016/j.chroma.2008.08.031] [Citation(s) in RCA: 89] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2008] [Revised: 05/21/2008] [Accepted: 08/11/2008] [Indexed: 11/25/2022]
|
9
|
B'Hymer C, Keil DE, Cheever KL. A Test Procedure for the Determination of (2-Methoxyethoxy)acetic Acid in Urine from Jet Fuel-Exposed Mice. Toxicol Mech Methods 2008; 15:367-73. [DOI: 10.1080/153765291009976] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
10
|
Barranco Martínez D, Martínez Galera M, Parrilla Vázquez P, Gil García MD. Simple and Rapid Determination of Benzoylphenylurea Pesticides in River Water and Vegetables by LC–ESI-MS. Chromatographia 2007. [DOI: 10.1365/s10337-007-0380-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
11
|
Michel M, Buszewski B. HPLC DETERMINATION OF PESTICIDE RESIDUE ISOLATED FROM FOOD MATRICES. J LIQ CHROMATOGR R T 2007. [DOI: 10.1081/jlc-120014004] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Monika Michel
- a Field Experimental Station in Torun , Pesticide Residue Laboratory , Plant Protection Institute in Poznan , 73 Zwirki i Wigury St., Torun, 87-100, Poland
| | - Boguslaw Buszewski
- b Department of Environmental Chemistry and Ecoanalytics , Faculty of Chemistry , Nicholaus Copernicus University , 7 Gagarin St., Torun, 87-100, Poland
| |
Collapse
|
12
|
Venkateswarlu P, Rama Mohan K, Ravi Kumar C, Seshaiah K. Monitoring of multi-class pesticide residues in fresh grape samples using liquid chromatography with electrospray tandem mass spectrometry. Food Chem 2007. [DOI: 10.1016/j.foodchem.2007.04.074] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
13
|
Niessen WMA, Manini P, Andreoli R. Matrix effects in quantitative pesticide analysis using liquid chromatography-mass spectrometry. MASS SPECTROMETRY REVIEWS 2006; 25:881-99. [PMID: 16783795 DOI: 10.1002/mas.20097] [Citation(s) in RCA: 301] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Combined liquid chromatography-mass spectrometry using electrospray or atmospheric-pressure chemical ionization has become an important tool in the quantitative analysis of pesticide residues in various matrices in relation to environmental analysis, food safety, and biological exposure monitoring. One of the major problems in the quantitative analysis using LC-MS is that compound and matrix-dependent response suppression or enhancement may occur, the so-called matrix effect. This article reviews issues related to matrix effects, focusing on quantitative pesticide analysis, but also paying attention to expertise with respect to matrix effects acquired in other application areas of LC-MS, especially quantitative bioanalysis in the course of drug development.
Collapse
Affiliation(s)
- W M A Niessen
- hyphen MassSpec, de Wetstraat 8, 2332 XT Leiden, The Netherlands
| | | | | |
Collapse
|
14
|
Kuster M, López de Alda M, Barceló D. Analysis of pesticides in water by liquid chromatography-tandem mass spectrometric techniques. MASS SPECTROMETRY REVIEWS 2006; 25:900-16. [PMID: 16705628 DOI: 10.1002/mas.20093] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Pesticide residues continue to be the focus of many environmental studies, and the number of articles describing the development of more advanced, multiresidue analytical methodologies does not decline. The use of liquid chromatography-mass spectrometry based on single quadrupole or ion trap analyzers is consolidated for this purpose. The implementation, in the near future, of more sophisticated mass analyzers, such as triple quadrupole and hybrid quadrupole-time-of-flight is anticipated for routine analysis. This article reviews the various works published so far in the literature for the determination of pesticides and transformation products (TPs) in water by means of liquid chromatography (LC) coupled to tandem mass spectrometry. It discusses the various ionization sources and analyzers used for this purpose, as well as the extraction procedures employed for previous sample preconcentration. Because of the widespread use of triple quadrupole analyzers for the generation of pesticides levels in water using tandem mass spectrometry, a table compiling the transitions monitored for ca. 70 compounds is also included.
Collapse
Affiliation(s)
- Marina Kuster
- Department of Environmental Chemistry, IIQAB-CSIC, Jordi Girona 18-26, 08034 Barcelona, Spain
| | | | | |
Collapse
|
15
|
Marín JM, Sancho JV, Pozo OJ, López FJ, Hernández F. Quantification and confirmation of anionic, cationic and neutral pesticides and transformation products in water by on-line solid phase extraction-liquid chromatography-tandem mass spectrometry. J Chromatogr A 2006; 1133:204-14. [PMID: 16970959 DOI: 10.1016/j.chroma.2006.08.055] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2006] [Revised: 08/01/2006] [Accepted: 08/10/2006] [Indexed: 11/15/2022]
Abstract
Two on-line SPE-LC-ESI-MS/MS methods have been developed for the rapid determination and confirmation of 18 polar pesticides and nine transformation products (TPs) in water samples. Given the very different physico-chemical characteristics of the analytes, it was not feasible the simultaneous determination of all selected compounds in only one method. Thus, it was necessary to use heptafluorobutyric acid and formic acid in order to obtain good retention in the SPE cartridge for basic and acidic analytes, respectively. The developed analytical methodology based on the direct injection of 2 mL of water sample in the system allowed the quantification of all analytes at the 25 ng/L level (LOQ) with limits of detection normally lower than 5 ng/L. Satisfactory recoveries (70-110%) were obtained for most compounds in ground and surface water samples. Some exceptions were found mainly in surface water, due to the ion suppression produced by the higher amount of matrix interferents in these samples. The acquisition of two MS/MS transitions for each compound allowed the reliable confirmation of positive findings even at the LOQ level. The developed methodology was applied to real ground and surface water samples showing the interest of including TPs in monitoring methods, as several of them were found at concentrations higher than that of parent compounds.
Collapse
Affiliation(s)
- José M Marín
- Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat s/n, E-12071 Castellón, Spain
| | | | | | | | | |
Collapse
|
16
|
Sancho JV, Pozo OJ, Ibáñez M, Hernández F. Potential of liquid chromatography/time-of-flight mass spectrometry for the determination of pesticides and transformation products in water. Anal Bioanal Chem 2006; 386:987-97. [PMID: 16736165 DOI: 10.1007/s00216-006-0532-0] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2006] [Revised: 05/03/2006] [Accepted: 05/05/2006] [Indexed: 10/24/2022]
Abstract
Until now, time-of-flight (TOF) mass analysers have only been very rarely used in pesticide residue analysis (PRA) of water samples. However, the inherent characteristics of TOF MS make these analysers well-suited to this field, mainly for qualitative purposes. Thus, the high sensitivity obtained from full-scan acquisition in comparison to other MS analysers and the high resolution of TOF MS suggest its suitability for screening purposes; it also increases the multiresidue capabilities of methods based on it and decreases the chance of recording false positives. Although these characteristics can also be helpful for quantification, confirmation and elucidation, some limitations on the use of TOF for these purposes have been observed. These limitations are more noticeable when dealing with samples containing very low analyte concentrations, which is the normal situation for PRA in water. The use of hybrid quadrupole-time-of-flight instruments (QTOF) minimises the limitations of TOF, facilitating the simultaneous detection and unequivocal confirmation of pesticides found in the sample. Additionally, the acquisition of accurate product ion full-scan mass spectra can help to elucidate the structures of unknown compounds. In this paper, the potential of TOF and QTOF hyphenated to liquid chromatography for PRA in water is explored, emphasizing both the advantages and limitations of this approach for screening, quantification, confirmation and elucidation purposes. Emphasis is placed on the determination of polar pesticides and transformation products-the analytes that fit well with LC-API-(Q)TOF MS technology.
Collapse
Affiliation(s)
- Juan V Sancho
- Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, 12071, Castellón, Spain.
| | | | | | | |
Collapse
|
17
|
Roose P, Brinkman UA. Monitoring organic microcontaminants in the marine environment: principles, programmes and progress. Trends Analyt Chem 2005. [DOI: 10.1016/j.trac.2005.10.007] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
18
|
Multiresidue determination of nicotinoid insecticide residues in drinking water by liquid chromatography with electrospray ionization mass spectrometry. Anal Chim Acta 2005. [DOI: 10.1016/j.aca.2005.08.006] [Citation(s) in RCA: 99] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
19
|
B'Hymer C, Butler MA, Cheever KL. Comparison and evaluation of analysis procedures for the quantification of (2-methoxyethoxy)acetic acid in urine. Anal Bioanal Chem 2005; 383:201-9. [PMID: 16158298 DOI: 10.1007/s00216-005-0048-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2005] [Revised: 06/24/2005] [Accepted: 06/29/2005] [Indexed: 11/29/2022]
Abstract
Several extraction and derivatization procedures were evaluated for the quantification of (2-methoxyethoxy)acetic acid (MEAA) in urine. MEAA is a metabolite and a biomarker for exposure to 2-(2-methoxyethoxy)ethanol, a glycol ether with widespread use in various industrial applications and the specific use as an anti-icing additive in the military jet fuel formulation JP-8. Quantification of glycol ether biomarkers is an active area of analytical research. Various sample preparation procedures were evaluated: liquid-liquid extraction (LLE) using ethyl acetate yielded the highest recovery, and solid-phase extraction (SPE) gave low recovery of MEAA. Two derivatization procedures were thoroughly investigated and validated, namely, silylation of MEAA with N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), and esterification of MEAA using ethanol. Quantification was performed by gas chromatography (GC) with a mass spectrometer as detector and using a polydimethylsiloxane (HP-1) capillary column. Deuterated 2-butoxyacetic acid (d-BAA) was used as an internal standard. Recovery studies of spiked human urine demonstrated the accuracy and precision of both procedures. The limit of detection (LOD) and other figures of merit for both derivatization procedures will be discussed in detail. Applications of these analysis procedures are also discussed.
Collapse
Affiliation(s)
- Clayton B'Hymer
- US Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Applied Research and Technology, Cincinnati, OH, 45226, USA.
| | | | | |
Collapse
|
20
|
Kampioti AA, Borba da Cunha AC, López de Alda M, Barceló D. Fully automated multianalyte determination of different classes of pesticides, at picogram per litre levels in water, by on-line solid-phase extraction–liquid chromatography–electrospray–tandem mass spectrometry. Anal Bioanal Chem 2005; 382:1815-25. [PMID: 16001237 DOI: 10.1007/s00216-005-3332-z] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2005] [Revised: 05/12/2005] [Accepted: 05/19/2005] [Indexed: 11/26/2022]
Abstract
This paper reports the development of a fully automated method for the multianalyte determination of twenty pesticides belonging to different classes (triazines, phenylureas, organophosphates, anilines, acidic, propanil, and molinate) in natural and treated waters. The method, based on on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry, is highly sensitive (limits of detection between 0.004 and 2.8 ng L(-1)), precise (relative standard deviations between 2.0 and 12.1%), reliable (two selected reaction-monitoring transitions are monitored per compound), rapid (45 min per sample), and simple. The application of this method to the monitoring of the target compounds in a waterworks revealed the presence of the pesticides investigated at concentrations up to 516 and 82 ng L(-1) (total pesticide concentration) in river water and ground water, respectively, used as sources, and their gradual removal through the purification process.
Collapse
Affiliation(s)
- Adamantia A Kampioti
- Laboratory of Biochemical Engineering and Environmental Technology, Department of Chemical Engineering, University of Patras, 26500 Patras, Greece
| | | | | | | |
Collapse
|
21
|
Hernández F, Pozo ÓJ, Sancho JV, López FJ, Marín JM, Ibáñez M. Strategies for quantification and confirmation of multi-class polar pesticides and transformation products in water by LC–MS2 using triple quadrupole and hybrid quadrupole time-of-flight analyzers. Trends Analyt Chem 2005. [DOI: 10.1016/j.trac.2005.04.007] [Citation(s) in RCA: 140] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
22
|
Dagnac T, Bristeau S, Jeannot R, Mouvet C, Baran N. Determination of chloroacetanilides, triazines and phenylureas and some of their metabolites in soils by pressurised liquid extraction, GC–MS/MS, LC–MS and LC–MS/MS. J Chromatogr A 2005; 1067:225-33. [PMID: 15844528 DOI: 10.1016/j.chroma.2004.11.058] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Pressurised liquid extraction (PLE) technique was used for the simultaneous extraction of phenylureas, triazines and chloroacetanilides and some of their metabolites from soils. Extractions were performed by mixing 15 g of dried soil with 30 mL of acetone under 100 atm at 50 degrees C, during 3 min and with three PLE cycles. Prior to the analysis of naturally contaminated soils, each of the five representative soil matrices used as blanks (of different depths) was spiked in triplicate with standards of each parent and degradation compound at about 10, 30 and 120 microg/kg. For each experiment, isoproturon-D6 and atrazine-D5 were used as surrogates. Analysis of phenylureas and metabolites of triazines and phenylureas was carried out by reversed phase liquid chromatography/mass spectrometry (LC-MS) and LC-MS/MS in the positive mode. Gas chromatography (GC)/ion trap mass spectrometry was used in the MS/MS mode for the parent triazines and chloroacetanilides. The average extraction recoveries were above 85%, except for didesmethyl-isoproturon, and quantification limits were between 0.5 and 5 microg/kg. The optimised multi-residue method was applied to soils and solids below the root zone, sampled from agricultural plots of a small French hydrogeological basin.
Collapse
Affiliation(s)
- T Dagnac
- BRGM, Service "Metrology, Monitoring andAnalysis", BP 6009, 45060 Orleans Cédex 2, France.
| | | | | | | | | |
Collapse
|
23
|
Soler C, Mañes J, Picó Y. Comparison of liquid chromatography using triple quadrupole and quadrupole ion trap mass analyzers to determine pesticide residues in oranges. J Chromatogr A 2005; 1067:115-25. [PMID: 15844516 DOI: 10.1016/j.chroma.2004.10.032] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Liquid chromatography-triple quadrupole/mass spectrometry (LC-TQ/MS) and liquid chromatography-quadrupole ion trap/mass spectrometry (LC-QIT/MS) for determining bupirimate, hexaflumuron, tebufenpyrad, buprofezin, pyriproxyfen, and fluvalinate in fruits have been compared. The differences in the mass spectra obtained by triple and ion trap quadrupoles are discussed, showing how both of them provide interesting features. The evaluation of the two instruments was carried out by ethyl acetate extraction of oranges spiked with the studied pesticides at LOQ and 10 times the LOQ. Results obtained by LC-TQ/MS correlated well with those obtained by LC-QIT/MS. Recoveries were 70-94% by LC-TQ/MS and 72-92% by LC-QIT/MS with the R.S.D. from five replicate analysis 4-14% and 8-18%, respectively. Matrix effects were tested for both techniques by standard addition to blank extracts. Although the matrix effects are not originated in mass analyzer but in the LC/MS interface, they were, generally, more marked by LC-QIT-MS than by LC-TQ/MS. The limits of quantification (LOQs) were 0.005-0.2 mg kg(-1) by both equipments--appropriate values for determining these pesticides in orange from the regulatory point of view. The results indicate that the TQ provides higher precision, better linearity, it is more robust, and when the purpose of the analysis is quantitative determination, preferable over the QIT. However, the application of both mass spectrometers to analyze orange samples conventionally treated showed that any can be used for qualitative and quantitative purposes.
Collapse
Affiliation(s)
- Carla Soler
- Laboratori de Bromatologia i Toxicologia, Facultat de Farmàcia, Universitat de València, 46100 Burjassot, València, Spain
| | | | | |
Collapse
|
24
|
Sannino A, Bandini M. Determination of seven benzoylphenylurea insecticides in processed fruit and vegetables using high-performance liquid chromatography/tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2005; 19:2729-33. [PMID: 16136517 DOI: 10.1002/rcm.2108] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A liquid chromatographic method with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) has been developed for the sensitive and selective determination of seven benzoylphenylurea insecticide residues (diflubenzuron, triflumuron, lufenuron, flufenoxuron, teflubenzuron, chlorfuazuron, hexaflumuron) in pear baby purée, concentrated lemon juice, and tomato pulp. The general sample extraction/partition method for our established multiresidue methods has been used. The entire procedure involves extraction of residues with acetone and partition into ethyl acetate/cyclohexane. Chromatographic determination was performed using a C18 column and isocratic elution. Fourteen MS/MS transitions of precursor ions were monitored (two for each pesticide) using negative ESI. The majority of mean recoveries at fortification levels of 0.002-0.020 and 0.020-0.200 mg/kg were in the range 77-102% with relative standard deviations between 2 and 10%. The excellent sensitivity and selectivity of this LC/MS/MS method allowed quantitation and identification at low levels in difficult matrices with a run time of 4 min.
Collapse
Affiliation(s)
- Anna Sannino
- Stazione Sperimentale per l'Industria delle Conserve Alimentari, Viale F.Tanara 31/A, 43100 Parma, Italy.
| | | |
Collapse
|
25
|
Sannino A, Bolzoni L, Bandini M. Application of liquid chromatography with electrospray tandem mass spectrometry to the determination of a new generation of pesticides in processed fruits and vegetables. J Chromatogr A 2004; 1036:161-9. [PMID: 15146917 DOI: 10.1016/j.chroma.2004.02.078] [Citation(s) in RCA: 170] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
This paper describes a method for the sensitive and selective determination of 24 new pesticide residues (azoxystrobin, trifloxystrobin, kresoxim-methyl, fenazaquin, indoxacarb, fenothiocarb, furathiocarb, benfuracarb, imidachloprid, dimethomorph, fenpyroximate, hexythiazox, tebufenpyrad, tebufenozide, difeconazole, fenbuconazole, flusilazole, paclobutrazol, tebuconazole, tetraconazole, bromuconazole, etofenprox, fenhexamid, pyridaben) in apple puree, concentrated lemon juice and tomato puree. A miniaturized extraction-partition procedure requiring small amounts of non-chlorinated solvents was used. The extracts are analyzed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) without any further clean-up step. The pesticides are separated on a reversed-phase polar column using a gradient elution. Fifty-five simultaneous MS-MS transitions of precursor ions were monitored (two or three for each pesticide). Studies at fortification levels of 0.001-0.020 and 0.010-0.200 mg/kg gave mean recoveries ranging from 76 to 106% for all compounds, except for imidacloprid, with (R.S.D.s) < or = 15%. The excellent sensitivity and selectivity of LC-MS-MS method allowed quantitation and identification at low levels also in difficult matrices with a run time of 20 min. With the developed method almost 100 samples of commercial fruit products (nectars, juices, purees) were analyzed. None of samples contained residues higher than 0.010 mg/kg.
Collapse
Affiliation(s)
- Anna Sannino
- Stazione Sperimentale per l'Industria delle Conserve Alimentari, Viale F Tanara 31/A, 43100 Parma, Italy.
| | | | | |
Collapse
|
26
|
B'Hymer C, Cheever KL. Development of a gas chromatographic test for the quantification of the biomarker 3-bromopropionic acid in human urine. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 802:361-6. [PMID: 15018799 DOI: 10.1016/j.jchromb.2003.12.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2003] [Revised: 12/02/2003] [Accepted: 12/04/2003] [Indexed: 11/19/2022]
Abstract
An accurate and precise method was developed for the detection and quantification of 3-bromopropionic acid (3-BPA), a metabolite and biomarker for exposure to 1-bromopropane (1-BP). 1-BP is used as an industrial solvent and exposure is a health concern for industrial workers due to its toxicity. It has been associated with neurological disorders in both animals and humans. Urine sample preparation for the determination of 3-BPA consisted of liquid-liquid extraction (LLE) with ethyl acetate and silylation with N-methyl-N-[tert-butyldimethylsilyl]trifluoroacetamide (MTBSTFA). Quantification was by means of a gas chromatograph (GC) equipped with a mass selective detector (MSD) using a dimethylpolysiloxane (HP-1) capillary column and 3-chloropropionic acid was used as an internal standard in the procedure. Demonstrated accuracy and precision during this method's validation was good; recovery varied between 93 and 98% with relative standard deviations (R.D.S.) of 5.7% or less. The limit of detection (LOD) for the procedure was approximately 0.01microg/ml 3-BPA in urine. These data and other factors of the development and validation of this test method will be discussed.
Collapse
Affiliation(s)
- C B'Hymer
- U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Applied Research and Technology, Taft Laboratory C-26, Cincinnati, OH 45226, USA.
| | | |
Collapse
|
27
|
Regnault C, Kano I, Darbouret D, Mabic S. Ultrapure water for liquid chromatography–mass spectrometry studies. J Chromatogr A 2004; 1030:289-95. [PMID: 15043281 DOI: 10.1016/j.chroma.2003.10.043] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Improvements in trace enrichment techniques combined with the sensitivity of mass spectrometry offer enhanced opportunities to analyze ever lower concentrations of drugs, metabolites, pesticides or environmental pollutants. To perform HPLC and liquid chromatography-mass spectrometry (LC-MS) analyses under optimum conditions, the water used for mobile phase preparation needs to be highly purified and delivered on demand. Indeed, both UV photodiode array detection and MS detection methods are sensitive to organic contaminants (total organic carbon, TOC), and the water quality has a direct impact on the achievable detection limits. The benefits of UV photooxidation on TOC reduction for LC-MS studies were highlighted using electrospray ionization MS detection by comparing HPLC-grade bottled water, freshly produced UV185/254-treated water, and freshly produced non-UV-treated water.
Collapse
Affiliation(s)
- Cecilia Regnault
- Research and Development, Lab Water Division, B.P. 307, Millipore, F-78094 St. Quentin-Yvelines, France
| | | | | | | |
Collapse
|
28
|
Benijts T, Dams R, Lambert W, De Leenheer A. Countering matrix effects in environmental liquid chromatography–electrospray ionization tandem mass spectrometry water analysis for endocrine disrupting chemicals. J Chromatogr A 2004; 1029:153-9. [PMID: 15032360 DOI: 10.1016/j.chroma.2003.12.022] [Citation(s) in RCA: 170] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In recent years, despite the increasing success of liquid chromatography (LC) coupled to tandem mass spectrometry (MS), reports on matrix susceptibility have shown the limitations of the this powerful analytical technique. Matrix effects (MEs) result from co-eluting residual matrix components affecting the ionization efficiency of target analytes and can lead to erroneous results. The present work evaluates the matrix effect of environmental water samples on 35 endocrine disrupting chemicals (EDCs) in negative and positive LC-ESI-MS/MS. It was shown that mobile-phase additives could significantly influence matrix effects. Addition of acids resulted in a severe signal suppression (average ME%: <65%), and 1 mM ammonium formate increased the average ME% to 84%. The importance of an efficient sample clean-up and internal standardization also was demonstrated. Cleaner extracts resulted in reduced matrix effects (average ME%: 89%) and labeled internal standards proved to have a beneficial effect especially on signal reproducibility (average CV% 4.2% versus 2.6%). The results from the present work indicate that evaluation of matrix effects should become an integrated part of quantitative LC-ESI-MS/MS method development and validation.
Collapse
Affiliation(s)
- Tom Benijts
- Laboratory of Toxicology, Ghent University, Harelbekestraat 72, B-9000 Gent, Belgium
| | | | | | | |
Collapse
|
29
|
Picó Y, Blasco C, Font G. Environmental and food applications of LC-tandem mass spectrometry in pesticide-residue analysis: an overview. MASS SPECTROMETRY REVIEWS 2004; 23:45-85. [PMID: 14625892 DOI: 10.1002/mas.10071] [Citation(s) in RCA: 180] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
An overview is given on pesticide-residue determination in environmental and food samples by liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS). Pesticides comprise a large number of substances that belong to many completely different chemical groups, the only common characteristic is that they are effective against pests. They still constitute a challenge in MS because there is no collective pathway for fragmentation. A brief introduction to the theory of tandem MS permits a discussion of which parameters influence the ionization efficiency when the ions are subjected to different actions. Emphasis is placed on the different tandem MS instruments: triple and ion-trap quadrupoles, and hybrid quadrupole time-of-flight (Q-TOF), including advantages and drawbacks, typical detection limits, and ion signals at low concentrations. The instrumental setup, as well as LC and mass spectrometric experimental conditions, must be carefully selected to increase the performance of the analytical system. The capacity of each instrument to provide useful data for the identification of pesticides, and the possibility to obtain structural information for the identification of target and non-target compounds, are discussed. Finally, sample preparation techniques and examples of applications are debated to reveal the potential of the current state-of-the-art technology, and to further promote the usefulness of tandem MS.
Collapse
Affiliation(s)
- Yolanda Picó
- Laboratori de Bromatologia i Toxicologia, Facultat de Farmàcia, Universitat de València, Av Vicent Andrés Estellés s/n, 46100 Burjassot, València, Spain.
| | | | | |
Collapse
|
30
|
B'Hymer C, Cheever KL, Butler MA, Brown KK. Procedure for the quantification of the biomarker (2-methoxyethoxy)acetic acid in human urine samples. J Chromatogr B Analyt Technol Biomed Life Sci 2003; 795:145-50. [PMID: 12957179 DOI: 10.1016/s1570-0232(03)00552-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
An accurate and precise procedure was developed for the detection and quantification of (2-methoxyethoxy)acetic acid (MEAA), a metabolite and biomarker for human exposure to 2-(2-methoxyethoxy)ethanol. The compound 2-(2-methoxyethoxy)ethanol has a wide array of industrial applications including its use as an additive in military jet fuel. Exposure to 2-(2-methoxyethoxy)ethanol is a health concern owing to its toxicity which includes developmental and teratogenic properties. Sample preparation consisted of liquid-liquid extraction (LLE) and esterification of MEAA to produce the ethyl ester. Measurement was by a gas chromatograph (GC) equipped with a mass selective detector (MSD) using a HP-1 capillary column. Recovery studies of spiked blank urine demonstrated good accuracy and precision; recovery varied between 95 and 103% with relative standard deviations of 8.6% and less. The limit of detection (LOD) for this procedure was found to range from 0.02 to 0.08 microg/ml equivalent levels of MEAA in urine. These data and other aspects of the validation of this procedure will be discussed.
Collapse
Affiliation(s)
- C B'Hymer
- Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Cincinnati, OH 45226, USA.
| | | | | | | |
Collapse
|
31
|
Abstract
The importance of sample preparation methods as the first stage in an analytical procedure is emphasised and examined. Examples are given of the extraction and concentration of analytes from solid, liquid and gas phase matrices, including solvent phase extractions, such as supercritical fluids and superheated water extraction, solid-phase extraction and solid-phase microextraction, headspace analysis and vapour trapping. The potential role of selective extraction methods, including molecular imprinted phases and affinity columns, are considered. For problem samples alternative approaches, such as derivatisation are discussed, and potential new approaches minimising sample preparation are noted.
Collapse
Affiliation(s)
- Roger M Smith
- Department of Chemistry, Loughborough University, Loughborough, Leics LE11 3TU, UK.
| |
Collapse
|
32
|
Wilson ID, Brinkman UAT. Hyphenation and hypernation the practice and prospects of multiple hyphenation. J Chromatogr A 2003; 1000:325-56. [PMID: 12877178 DOI: 10.1016/s0021-9673(03)00504-1] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
In the past two decades, combining a chromatographic separation system on-line with a spectroscopic detector in order to obtain structural information on the analytes present in a sample has become the most important approach for the identification and/or confirmation of the identity of target and unknown chemical compounds. In most instances, such hyphenation can be accomplished by using commercially available equipment For most (trace-level) analytical problems encountered today, the combination of column liquid chromatography or capillary gas chromatography with a mass spectrometer (LC-MS and GC-MS, respectively) is the preferred approach. However, it is also true that additional and/or complementary information is, in quite a number of cases, urgently required. This can be provided by, for example, atomic emission, Fourier-transform infrared, diode-array UV-vis absorbance or fluorescence emission, or nuclear magnetic resonance spectrometry. In the present review, the various options are briefly discussed and a few relevant applications are quoted for each combination. Special attention is devoted to systems in which multiple hyphenation, or hypernation, is an integral part of the setup. As regards this topic, the relative merits of various combinations--which turn out to include a mass spectrometer as one of the detectors in essentially all cases--are discussed and the fundamental differences between GC- and LC-based systems are outlined. Finally, the practicability of more extensive hypernation in LC, viz. with up to four spectrometers, is discussed. It is demonstrated that, technically, such multiple hyphenation is possible and that, from a practical point of view, rewarding results can be obtained. In other words, further research in this area is certainly indicated. However, in the foreseeable future, using several separate conventional hyphenated systems will be the commonly implemented solution in most instances.
Collapse
Affiliation(s)
- I D Wilson
- Department of Drug Metabolism and Pharmacokinetics, AstraZeneca, Mereside, Alderley Park, Macclesfield, Cheshire SK10 4TG, UK.
| | | |
Collapse
|
33
|
Simultaneous determination of a wide spectrum of pesticides in water by means of fast on-line SPE-HPLC-MS-MS—a novel approach. Chromatographia 2003. [DOI: 10.1007/bf02492090] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
34
|
Marriott P. The Nobel Prize 2002 - Molecular Analysis Rewarded. J Sep Sci 2003. [DOI: 10.1002/jssc.200390015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
35
|
Geerdink RB, Niessen WMA, Brinkman UAT. Trace-level determination of pesticides in water by means of liquid and gas chromatography. J Chromatogr A 2002; 970:65-93. [PMID: 12350103 DOI: 10.1016/s0021-9673(02)00234-0] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The trace-level determination of pesticides and their transformation products (TPs) in water by means of liquid and gas chromatography (LC and GC) is reviewed. Special attention is given to the use of (tandem) mass spectrometry for identification and confirmation purposes. The complementarity of LC- and GC-based techniques and the potential of comprehensive GCXGC are discussed, and also the impressive performance of time-of-flight mass spectrometry. It is also indicated that, in the near future, the TPs rather than the parent compounds should receive most attention--with a better understanding of matrix effects and eluent composition on the ionization efficiency of analytes being urgently required. Finally, the merits of using much shorter LC columns, or even no column at all (flow-injection analysis) in target analysis are shown, and a more cost-efficient and sophisticated strategy for monitoring programmes is briefly introduced.
Collapse
Affiliation(s)
- R B Geerdink
- Institute for Inland Water Management and Waste Water Treatment, RIZA, Lelystad, The Netherlands
| | | | | |
Collapse
|
36
|
Asperger A, Efer J, Koal T, Engewald W. Trace determination of priority pesticides in water by means of high-speed on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry using turbulent-flow chromatography columns for enrichment and a short monolithic column for fast liquid chromatographic separation. J Chromatogr A 2002; 960:109-19. [PMID: 12150548 DOI: 10.1016/s0021-9673(01)01392-9] [Citation(s) in RCA: 112] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
An integrated on-line SPE-HPLC-MS/MS system has been developed for the rapid analysis of various trace level priority pesticides in surface and drinking water. Eleven pesticides were included in this study, with various phenylureas, triazines and organophosphorous species among them. Use of turbulent-flow chromatography columns (TFC, 50 x 1 mm, 30-50 microm particle size) as extraction cartridges enables fast on-line SPE at high sampling flow-rate (5 ml/min). Polymeric and carbon based TFC columns (Oasis HLB, Cyclone, Hypercarb) allow complete extraction with good recoveries from water volumes up to 50 ml. On-line coupling to HPLC is performed with re-mixing of the organic TFC eluate with water in front of the analytical column to ensure efficient band focussing. For fast HPLC analysis, a short monolithic column is applied in combination with highly selective API-MS/MS detection. Matrix effects on the APCI-MS/MS signal were found to be reduced by the system to an acceptable minimum. Limits of detection, determined for 10-ml samples of river water were in the range between 0.4 and 13 ng/l typically, except trifluralin (approximately 280 ng/l), which is less susceptible to ionization under atmospheric pressure conditions. At an enriched water volume of 10 ml, the whole SPE-HPLC-MS/MS procedure requires less than 14 min. The method was successfully applied to the analysis of drinking and surface water samples taken from several sampling sites around the city of Leipzig, Germany. Concentrations measured (maximum: 16 ng/l simazine in river water) were far below the concentration limits scheduled by law.
Collapse
Affiliation(s)
- Arndt Asperger
- Leipzig University, Institute of Analytical Chemistry, Germany.
| | | | | | | |
Collapse
|
37
|
Bibliography. Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2001; 36:1241-1248. [PMID: 11747122 DOI: 10.1002/jms.98] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|