1
|
Owda AY. A New Method for Detecting Dehydration of the Human Body Using Non-Contact Millimeter Wave Radiometry. SENSORS (BASEL, SWITZERLAND) 2024; 24:4461. [PMID: 39065857 PMCID: PMC11280757 DOI: 10.3390/s24144461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Revised: 07/06/2024] [Accepted: 07/09/2024] [Indexed: 07/28/2024]
Abstract
Dehydration is a common problem in the aging population. Medical professionals can detect dehydration using either blood or urine tests. This requires experimental tests in the lab as well as urine and blood samples to be obtained from the patients. This paper proposed 100 GHz millimeter wave radiometry for early detection of dehydration. Reflectance measurements were performed on healthy and dehydrated patients of both genders (120 males and 80 females) in the aging population. Based on the cause of dehydration, the patient groups were divided into three categories: (1) patients dehydrated due to less thirst sensation, (2) patients dehydrated due to illnesses (vomiting and diarrhea), and (3) patients dehydrated due to diabetes. Reflectance measurements were performed on eight locations: (1) the palm, (2) the back of the hand, (3) the fingers, (4) the inner wrist, (5) the outer wrist, (6) the volar side of the arm, (7) the dorsal surface of the arm, and (8) the elbow. Skin dehydrated due to vomiting and diarrhea was found to have lower reflectance at all the measurement locations compared with healthy and other types of dehydrated skin. The elbow region showed the highest difference in reflectance between healthy and dehydrated skin. This indicates that radiometric sensitivity is sufficient to detect dehydration in a few seconds. This will reduce the patient's waiting time and the healthcare professional's intervention time as well as allow early treatment of dehydration, thus avoiding admission to hospitals.
Collapse
Affiliation(s)
- Amani Yousef Owda
- Department of Natural, Engineering and Technology Sciences, Arab American University, Ramallah P600, Palestine
| |
Collapse
|
2
|
Owda AY, Owda M. Early Detection of Skin Disorders and Diseases Using Radiometry. Diagnostics (Basel) 2022; 12:diagnostics12092117. [PMID: 36140518 PMCID: PMC9498219 DOI: 10.3390/diagnostics12092117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 08/27/2022] [Accepted: 08/30/2022] [Indexed: 11/30/2022] Open
Abstract
Skin diseases and disorders have a significant impact on people’s health and quality of life. Current medical practice suggests different methodologies for detecting and diagnosing skin diseases and conditions. Most of these require medical tests, laboratory analyses, images, and healthcare professionals to assess the results. This consumes time, money, and effort, and the waiting time is stressful for the patient. Therefore, it is an essential requirement to develop a new automatic method for the non-invasive diagnosis of skin diseases and disorders without the need for healthcare professionals or being in a medical clinic. This research proposes millimeter-wave (MMW) radiometry as a non-contact sensor for the non-invasive diagnosis of skin diseases and conditions. Reflectance measurements performed using 90 GHz radiometry were conducted on two samples of participants; sample 1 consisted of 60 participants (30 males and 30 females) with healthy skin, and sample 2 contained 60 participants (30 males and 30 females) suffering from skin diseases and conditions, which were: basal cell carcinoma (BCC), squamous cell carcinoma (SCC), burn wounds, and eczema. Radiometric measurements show substantial differences in reflectance in the range of 0.02–0.27 between healthy and unhealthy regions of the skin on the same person. These results indicate that radiometry, as a non-contact sensor, can identify and distinguish between healthy and diseased regions of the skin. This indicates the potential of using radiometry as a non-invasive technique for the early detection of skin diseases and disorders.
Collapse
Affiliation(s)
- Amani Yousef Owda
- Department of Natural, Engineering and Technology Sciences, Arab American University, Ramallah P600, Palestine
- Correspondence:
| | - Majdi Owda
- Faculty of Data Science, Arab American University, Ramallah P600, Palestine
| |
Collapse
|
3
|
Owda AY. Passive Millimeter-Wave Imaging for Burns Diagnostics under Dressing Materials. SENSORS (BASEL, SWITZERLAND) 2022; 22:2428. [PMID: 35408043 PMCID: PMC9003280 DOI: 10.3390/s22072428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 03/18/2022] [Accepted: 03/19/2022] [Indexed: 06/14/2023]
Abstract
This paper presents a feasibility study of using a passive millimeter-wave imaging (PMMWI) system to assess burn wounds and the potential for monitoring the healing process under dressing materials, without their painful removal. Experimental images obtained from ex vivo porcine skin samples indicate that a ThruVision passive imager operating over the band 232-268 GHz can be used for diagnosing burns and for potentially monitoring the healing under dressing materials. Experimental images show that single and multiple burns are observed throughout dressing materials. As the interaction of millimeter-wave (MMW) radiation with the human body is almost exclusively with the skin, the major outcomes of the research are that PMMWI is capable of discriminating burn-damaged skin from unburned skin, and these measurements can be made through bandages without the imager making any physical contact with the skin or the bandage. This highlights the opportunity that the healing of burn wounds can be assessed and monitored without the removal of dressing materials. The key innovation in this work is in detecting single and multiple burns under dressing materials in noncontact with the skin and without exposing the skin to any type of manmade radiation (i.e., passive sensing technology). These images represent the first demonstration of burns wound under dressing materials using a passive sensing imager.
Collapse
Affiliation(s)
- Amani Yousef Owda
- Department of Natural, Engineering and Technology Sciences, Arab American University, Ramallah P600, Palestine
| |
Collapse
|
4
|
Abstract
The classical dogma states that brown adipose tissue (BAT) plays a major role in the regulation of temperature in neonates. However, although BAT has been studied in infants for more than a century, the knowledge about its physiological features at this stage of life is rather limited. This has been mainly due to the lack of appropriate investigation methods, ethically suitable for neonates. Here, we have applied non-invasive infrared thermography (IRT) to investigate neonatal BAT activity. Our data show that BAT temperature correlates with body temperature and that mild cold stimulus promotes BAT activation in newborns. Notably, a single short-term cold stimulus during the first day of life improves the body temperature adaption to a subsequent cold event. Finally, we identify that bone morphogenic protein 8B (BMP8B) is associated with the BAT thermogenic response in neonates. Overall, our data uncover key features of the setup of BAT thermogenesis in newborns.
Collapse
|
5
|
THz Sensing of Human Skin: A Review of Skin Modeling Approaches. SENSORS 2021; 21:s21113624. [PMID: 34070962 PMCID: PMC8197005 DOI: 10.3390/s21113624] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 05/13/2021] [Accepted: 05/19/2021] [Indexed: 12/11/2022]
Abstract
The non-ionizing and non-invasive nature of THz radiation, combined with its high sensitivity to water, has made THz imaging and spectroscopy highly attractive for in vivo biomedical applications for many years. Among them, the skin is primarily investigated due to the short penetration depth of THz waves caused by the high attenuation by water in biological samples. However, a complete model of skin describing the THz-skin interaction is still needed. This is also fundamental to reveal the optical properties of the skin from the measured THz spectrum. It is crucial that the correct model is used, not just to ensure compatibility between different works, but more importantly to ensure the reliability of the data and conclusions. Therefore, in this review, we summarize the models applied to skin used in the THz regime, and we compare their adaptability, accuracy, and limitations. We show that most of the models attempt to extract the hydration profile inside the skin while there is also the anisotropic model that displays skin structural changes in the stratum corneum.
Collapse
|
6
|
Leszczynski D. Physiological effects of millimeter-waves on skin and skin cells: an overview of the to-date published studies. REVIEWS ON ENVIRONMENTAL HEALTH 2020; 35:493-515. [PMID: 32829319 DOI: 10.1515/reveh-2020-0056] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 05/27/2020] [Indexed: 06/11/2023]
Abstract
The currently ongoing deployment if the fifth generation of the wireless communication technology, the 5G technology, has reignited the health debate around the new kind of radiation that will be used/emitted by the 5G devices and networks - the millimeter-waves. The new aspect of the 5G technology, that is of concern to some of the future users, is that both, antennas and devices will be continuously in a very close proximity of the users' bodies. Skin is the only organ of the human body, besides the eyes, that will be directly exposed to the mm-waves of the 5G technology. However, the whole scientific evidence on the possible effects of millimeter-waves on skin and skin cells, currently consists of only some 99 studies. This clearly indicates that the scientific evidence concerning the possible effects of millimeter-waves on humans is insufficient to devise science-based exposure limits and to develop science-based human health policies. The sufficient research has not been done and, therefore, precautionary measures should be considered for the deployment of the 5G, before the sufficient number of quality research studies will be executed and health risk, or lack of it, scientifically established.
Collapse
|
7
|
Passive Detection and Imaging of Human Body Radiation Using an Uncooled Field-Effect Transistor-Based THz Detector. SENSORS 2020; 20:s20154087. [PMID: 32707924 PMCID: PMC7435787 DOI: 10.3390/s20154087] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 07/16/2020] [Accepted: 07/20/2020] [Indexed: 11/30/2022]
Abstract
This work presents, to our knowledge, the first completely passive imaging with human-body-emitted radiation in the lower THz frequency range using a broadband uncooled detector. The sensor consists of a Si CMOS field-effect transistor with an integrated log-spiral THz antenna. This THz sensor was measured to exhibit a rather flat responsivity over the 0.1–1.5-THz frequency range, with values of the optical responsivity and noise-equivalent power of around 40 mA/W and 42 pW/Hz, respectively. These values are in good agreement with simulations which suggest an even broader flat responsivity range exceeding 2.0 THz. The successful imaging demonstrates the impressive thermal sensitivity which can be achieved with such a sensor. Recording of a 2.3 × 7.5-cm2-sized image of the fingers of a hand with a pixel size of 1 mm2 at a scanning speed of 1 mm/s leads to a signal-to-noise ratio of 2 and a noise-equivalent temperature difference of 4.4 K. This approach shows a new sensing approach with field-effect transistors as THz detectors which are usually used for active THz detection.
Collapse
|
8
|
The Reflectance of Human Skin in the Millimeter-Wave Band. SENSORS 2020; 20:s20051480. [PMID: 32182667 PMCID: PMC7085580 DOI: 10.3390/s20051480] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 03/02/2020] [Accepted: 03/06/2020] [Indexed: 11/17/2022]
Abstract
The millimeter-wave band is an ideal part of the electromagnetic radiation to diagnose human skin conditions because this radiation interacts only with tissue down to a depth of a millimetre or less over the band range from 30 GHz to 300 GHz. In this paper, radiometry is used as a non-contact sensor for measuring the human skin reflectance under normal and wet skin conditions. The mean reflectance of the skin of a sample of 50 healthy participants over the (80-100) GHz band was found to be ~0.615 with a standard deviation of ~0.088, and an experimental measurement uncertainty of ±0.005. The thinner skin regions of the back of the hand, the volar forearms and the inner wrist had reflectances 0.068, 0.068 and 0.062 higher than the thicker skin regions of the palm of the hand, the dorsal forearm and the outer wrist skin. Experimental measurements of human skin reflectance in a normal and a wet state on the back of the hand and the palm of the hand regions indicated that the mean differences in the reflectance before and after the application of water were ~0.078 and ~0.152, respectively. These differences were found to be statistically significant as assessed using t-tests (34 paired t-tests and six independent t-tests were performed to assess the significance level of the mean differences in the reflectance of the skin). Radiometric measurements in this paper show the quantitative variations in the skin reflectance between locations, sexes, and individuals. The study reveals that these variations are related to the skin thickness and water content, a capability that has the potential to allow radiometry to be used as a non-contact sensor to detect and monitor skin conditions such as eczema, psoriasis, malignancy, and burn wounds.
Collapse
|
9
|
Synthetic Aperture Radar Imaging for Burn Wounds Diagnostics. SENSORS 2020; 20:s20030847. [PMID: 32033414 PMCID: PMC7038763 DOI: 10.3390/s20030847] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 01/31/2020] [Accepted: 02/03/2020] [Indexed: 11/17/2022]
Abstract
The need for technologies to monitor the wound healing under dressing materials has led us to investigate the feasibility of using microwave and millimetre wave radiations due to their sensitivity to water, non- ionising nature, and transparency to dressing materials and clothing. This paper presents synthetic aperture radar (SAR) images obtained from an active microwave and millimetre wave scanner operating over the band 15–40 GHz. Experimental images obtained from porcine skin samples with the presence of dressing materials and after the application of localised heat treatments reveal that SAR images can be used for diagnosing burns and for potentially monitoring the healing under dressing materials. The experimental images were extracted separately from the amplitude and phase measurements of the input reflection coefficient (S11). The acquired images indicate that skin and burns can be detected and observed through dressing materials as well as features of the skin such as edges, irregularities, bends, burns, and variation in the reflectance of the skin. These unique findings enable a microwave and millimetre-wave scanner to be used for evaluating the wound healing progress under dressing materials without their often-painful removal: a capability that will reduce the cost of healthcare, distress caused by long waiting hours, and the healthcare interventional time.
Collapse
|
10
|
Mattsson MO, Simkó M. Emerging medical applications based on non-ionizing electromagnetic fields from 0 Hz to 10 THz. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2019; 12:347-368. [PMID: 31565000 PMCID: PMC6746309 DOI: 10.2147/mder.s214152] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 08/23/2019] [Indexed: 12/13/2022] Open
Abstract
The potential for using non-ionizing electromagnetic fields (EMF; at frequencies from 0 Hz up to the THz range) for medical purposes has been of interest since many decades. A number of established and familiar methods are in use all over the world. This review, however, provides an overview of applications that already play some clinical role or are in earlier stages of development. The covered methods include modalities used for bone healing, cancer treatment, neurological conditions, and diathermy. In addition, certain other potential clinical areas are touched upon. Most of the reviewed technologies deal with therapy, whereas just a few diagnostic approaches are mentioned. None of the discussed methods are having such a strong impact in their field of use that they would be expected to replace conventional methods. Partly this is due to a knowledge base that lacks mechanistic explanations for EMF effects at low-intensity levels, which often are used in the applications. Thus, the possible optimal use of EMF approaches is restricted. Other reasons for the limited impact include a scarcity of well-performed randomized clinical trials that convincingly show the efficacy of the methods and that standardized user protocols are mostly lacking. Presently, it seems that some EMF-based methods can have a niche role in treatment and diagnostics of certain conditions, mostly as a complement to or in combination with other, more established, methods. Further development and a stronger impact of these technologies need a better understanding of the interaction mechanisms between EMF and biological systems at lower intensity levels. The importance of the different physical parameters of the EMF exposure needs also further investigations.
Collapse
Affiliation(s)
- Mats-Olof Mattsson
- SciProof International AB, Östersund, Sweden
- Strömstad Akademi, Institute for Advanced Studies, Strömstad, Sweden
| | - Myrtill Simkó
- SciProof International AB, Östersund, Sweden
- Strömstad Akademi, Institute for Advanced Studies, Strömstad, Sweden
| |
Collapse
|
11
|
Owda AY, Salmon N, Shylo S, Owda M. Assessment of Bandaged Burn Wounds Using Porcine Skin and Millimetric Radiometry. SENSORS 2019; 19:s19132950. [PMID: 31277437 PMCID: PMC6651191 DOI: 10.3390/s19132950] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 06/30/2019] [Accepted: 07/02/2019] [Indexed: 11/16/2022]
Abstract
This paper describes the experimental setup and measurements of the emissivity of porcine skin samples over the band of 80–100 GHz. Measurements were conducted on samples with and without dressing materials and before and after the application of localized heat treatments. Experimental measurements indicate that the differences in the mean emissivity values between unburned skin and burned damaged skin was up to ~0.28, with an experimental measurement uncertainty of ±0.005. Measured differences in the mean emissivity values between unburned and burn damaged skin increases with the depth of the burn, indicating a possible non-contact technique for assessing the degree of a burn. The mean emissivity of the dressed burned skin was found to be slightly higher than the undressed burned skin, typically ~0.01 to ~0.02 higher. This indicates that the signature of the burn caused by the application of localized heat treatments is observable through dressing materials. These findings reveal that radiometry, as a non-contact method, is capable of distinguishing between normal and burn-damaged skin under dressing materials without their often-painful removal. This indicates the potential of using millimeter wave (MMW) radiometry as a new type of medical diagnostic to monitor burn wounds.
Collapse
Affiliation(s)
- Amani Yousef Owda
- School of Electrical and Electronic Engineering, University of Manchester, Sackville Street Building, Manchester M13 9PL, UK.
| | - Neil Salmon
- School of Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
| | - Sergiy Shylo
- Usikov Institute of Radiophysics and Electronics National Academy of Sciences of Ukraine, 61085 Kharkov, Ukraine
| | - Majdi Owda
- School of Computing, Mathematics and Digital Technology, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
| |
Collapse
|