Kwantwi-Barima P, Hollerbach AL, Attah IK, Norheim RV, Ibrahim YM. Ion Mobility Separations Using Cocentric Architecture. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:1576-1583. [PMID: 38859729 DOI: 10.1021/jasms.4c00163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2024]
Abstract
Ion mobility separations, especially using drift tube ion mobility spectrometers, are usually performed in linear channels, which can have a large footprint when extended to achieve higher resolving powers. In this work, we explored the performance of an ion mobility device with a curved architecture, which can have a more compact form. The cocentric ion mobility spectrometer (CoCIMS) manipulates ions between two cocentric surfaces containing a serpentine track. The mobility separation inside the CoCIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside the CoCIMS they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path. We then performed experimental validation of the CoCIMS in conjunction with a TOF MS. The CoCIMS was made of two flexible printed circuit board materials folded into cocentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter ×152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and an eight-peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). The average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW) for tetraalkylammonium ions. The resolving power of the peptide mixture ions was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TWCCS for the peptide mixture ions was about 0.4%. The new device showed promising results, but improvements are needed to further increase the resolving power.
Collapse
Affiliation(s)
- Pearl Kwantwi-Barima
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Adam L Hollerbach
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Isaac K Attah
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Randolph V Norheim
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| |
Collapse
|
2
|
Abstract
Metabolomics aims to profile the extensive array of metabolites that exists in different types of matrices using modern analytical techniques. These techniques help to separate, identify, and quantify the plethora of chemical compounds at various analytical platforms. Hence, ion mobility spectrometry (IMS) has emerged as an advanced analytical approach, exclusively owing to the 3D separation of metabolites and their isomers. Furthermore, separated metabolites are identified based on their mass fragmentation pattern and CCS (collision cross-section) values. The IMS provides an advanced alternative dimension to separate the isomeric metabolites with enhanced throughput with lesser chemical noise. Thus, the present review highlights the types, factors affecting the resolution, and applications of IMMS (Ion mobility mass spectrometry) for isomeric separations, and ionic contaminants in the plant samples. Furthermore, an overview of IMS-based applications for the identification of plant metabolites (volatile and non-volatile) over the last few decades has been discussed, followed by future assumptions for creating IM-based databases. Such approaches could be significant to accelerate and improve our knowledge of the vast chemical diversity found in plants.
Collapse
Affiliation(s)
- Robin Joshi
- Biotechnology Division, CSIR-Institute of Himalayan Bioresource Technology, Palampur, Himachal Pradesh, India
- Academy of Scientific and Innovative Research, (AcSIR), Ghaziabad, India
| | - Shruti Sharma
- Academy of Scientific and Innovative Research, (AcSIR), Ghaziabad, India
- Chemical Technology Division, CSIR-Institute of Himalayan Bioresource Technology, Palampur, Himachal Pradesh, India
| | - Dinesh Kumar
- Academy of Scientific and Innovative Research, (AcSIR), Ghaziabad, India
- Chemical Technology Division, CSIR-Institute of Himalayan Bioresource Technology, Palampur, Himachal Pradesh, India
| |
Collapse
|
3
|
Kwantwi-Barima P, Garimella SVB, Attah IK, Zheng X, Ibrahim YM, Smith RD. Accumulation of Large Ion Populations with High Ion Densities and Effects Due to Space Charge in Traveling Wave-Based Structures for Lossless Ion Manipulations (SLIM) IMS-MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:365-377. [PMID: 38175933 PMCID: PMC10853970 DOI: 10.1021/jasms.3c00389] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 11/19/2023] [Accepted: 12/13/2023] [Indexed: 01/06/2024]
Abstract
The accumulation of very large ion populations in traveling wave (TW)-based Structures for Lossless ion Manipulations (SLIM) has been studied to better understand aspects of "in-SLIM" ion accumulation, and particularly its use in conjunction with ion mobility spectrometry (IMS). A linear SLIM ion path was implemented that had a "gate" for blocking and accumulating ions for arbitrary time periods. Removing the gate potential caused ions to exit, and the spatial distributions of accumulated ions examined. The ion populations for a set of peptides increased approximately linearly with increased accumulation times until space change effects became significant, after which the peptide precursor ion populations decreased due to growing space charge-related ion activation, reactions, and losses. Ion activation increased with added storage times and the TW amplitude. Lower amplitude TWs in the accumulation/storage region prevented or minimized ion losses or ion heating effects that can also lead to fragmentation. Our results supported the use of an accumulation region close to the SLIM entrance for speeding accumulation, minimizing ion heating, and avoiding ion population profiles that result in IMS peak tailing. Importantly, space charge-driven separations were observed for large populations of accumulated species and attributed to the opposing effects of space charge and the TW. In these separations, ion species form distributions or peaks, sometimes moving against the TW, and are ordered in the SLIM based on their mobilities. Only the highest mobility ions located closest to the gate in the trapped ion population (and where the highest ion densities were achieved) were significantly activated. The observed separations may offer utility for ion prefractionation of ions and increasing the dynamic range measurements, increasing the resolving power of IMS separations by decreasing peak widths for accumulated ion populations, and other purposes benefiting from separations of extremely large ion populations.
Collapse
Affiliation(s)
- Pearl Kwantwi-Barima
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Sandilya V. B. Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Isaac K. Attah
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Xueyun Zheng
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Yehia M. Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Richard D. Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| |
Collapse
|
4
|
Atakay M. Monitoring Conformational Changes of Lysozyme–Polyelectrolyte Complexes Using Trapped Ion Mobility-Mass Spectrometry (IM-MS). ANAL LETT 2023. [DOI: 10.1080/00032719.2023.2173768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Affiliation(s)
- Mehmet Atakay
- Department of Chemistry, Hacettepe University, Ankara, Turkey
| |
Collapse
|
5
|
Kwantwi-Barima P, Harrilal CP, Garimella SVB, Attah IK, Smith RD, Ibrahim YM. Effect of Traveling Waveform Profiles on Collision Cross Section Measurements in Structures for Lossless Ion Manipulations. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:783-792. [PMID: 35437008 PMCID: PMC10634343 DOI: 10.1021/jasms.1c00364] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
We evaluated the effect of four different waveform profiles (Square, Sine, Triangle, and asymmetric Sawtooth) on the accuracy of collision cross section (CCS) measurements using traveling wave ion mobility spectrometry (TWIMS) separations in structures for lossless ion manipulations (SLIM). The effects of the waveform profiles on the accuracy of the CCS measurements were evaluated for four classes of compounds (lipids, peptides, steroids, and nucleosides) at different TW speeds (126-206 m/s) and amplitudes (15-89 V). For the lipids and peptides, the TWIMS-based CCS (TWCCS) deviations from the corresponding drift-tube-based CCS (DTCCS) measurements were significantly lower in experiments conducted using the Sawtooth waveform compared to the square waveform. This observation can be rationalized by the lower maximum electric field experienced by ions with a Sawtooth waveform, as compared to the other waveforms, resulting in a lower probability for significant ion heating. We also observed that given approximately comparable resolution for all four waveforms, the Sawtooth waveform resulted in lower TWCCS error and a better agreement with DTCCS values than the Square waveform. In addition, for the steroids and nucleosides, an opposite TWCCS trend was observed, with higher errors with the Sawtooth waveform and lower with the Square waveform, suggesting that these molecules tend to become slightly more compact under ion heating conditions. Under optimum conditions, all TWCCS measurements on the SLIM platform were within 0.5% of those measured in the drift tube ion mobility spectrometry.
Collapse
Affiliation(s)
- Pearl Kwantwi-Barima
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Christopher P Harrilal
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Sandilya V B Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Isaac K Attah
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| |
Collapse
|
6
|
Warnke S, Ben Faleh A, Pellegrinelli RP, Yalovenko N, Rizzo TR. Combining ultra-high resolution ion mobility spectrometry with cryogenic IR spectroscopy for the study of biomolecular ions. Faraday Discuss 2020; 217:114-125. [PMID: 30993271 PMCID: PMC6657637 DOI: 10.1039/c8fd00180d] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
We explore the capability of SLIM-based IMS for isomer selectivity in combination with cryogenic, messenger-tagging IR spectroscopy.
Double-resonance spectroscopic schemes in combination with cryogenic ion traps are the go-to techniques when isomer-specific high-resolution spectra are required for analysis of molecular ions. Their limitation lies in the requirement for well-resolved, isomer-specific absorption bands as well as in the potentially time-consuming steps to identify each isomer. We present an alternative approach where isomeric species are readily separated using ion mobility spectrometry (IMS) and selected prior to cryogenic spectroscopic analysis. To date, most IMS approaches suffer from relatively low resolution, however, recent technological developments in the field of travelling-wave ion mobility using structures for lossless ion manipulation (SLIM) permit the use of extremely long drift paths, which greatly enhances the resolution. We demonstrate the power of combining this type of ultra-high resolution IMS with cryogenic vibrational spectroscopy by comparing mobility-resolved IR spectra of a disaccharide to those acquired using IR–IR double resonance. This new approach is especially promising for the investigation of larger molecules where spectral congestion interferes with double resonance techniques.
Collapse
Affiliation(s)
- Stephan Warnke
- Laboratoire de Chimie Physique Moléculaire, École Polytechnique Fédérale de Lausanne, EPFL SB ISIC LCPM, Station 6, CH-1015 Lausanne, Switzerland.
| | - Ahmed Ben Faleh
- Laboratoire de Chimie Physique Moléculaire, École Polytechnique Fédérale de Lausanne, EPFL SB ISIC LCPM, Station 6, CH-1015 Lausanne, Switzerland.
| | - Robert P Pellegrinelli
- Laboratoire de Chimie Physique Moléculaire, École Polytechnique Fédérale de Lausanne, EPFL SB ISIC LCPM, Station 6, CH-1015 Lausanne, Switzerland.
| | - Natalia Yalovenko
- Laboratoire de Chimie Physique Moléculaire, École Polytechnique Fédérale de Lausanne, EPFL SB ISIC LCPM, Station 6, CH-1015 Lausanne, Switzerland.
| | - Thomas R Rizzo
- Laboratoire de Chimie Physique Moléculaire, École Polytechnique Fédérale de Lausanne, EPFL SB ISIC LCPM, Station 6, CH-1015 Lausanne, Switzerland.
| |
Collapse
|
7
|
Nano electrospray differential mobility analysis based size-selection of liposomes and very-low density lipoprotein particles for offline hyphenation to MALDI mass spectrometry. J Pharm Biomed Anal 2020; 179:112998. [PMID: 31780280 DOI: 10.1016/j.jpba.2019.112998] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 11/14/2019] [Accepted: 11/17/2019] [Indexed: 11/21/2022]
Abstract
Gas-phase electrophoresis of single-charged analytes (nanoparticles) enables their separation according to the surface-dry particle size (Electrophoretic Mobility Diameter, EMD), which corresponds to the diameter of spherical shaped particles. Employing a nano Electrospray Differential Mobility Analyzer (nES DMA), also known as nES Gas-phase Electrophoretic Mobility Molecular Analyzer (nES GEMMA), allows sizing/size-separation and determination of particle-number concentrations. Separations are based on a constant high laminar sheath flow and a tunable, orthogonal electric field enabling scanning of EMDs in the nanometer size range. Additionally, keeping the voltage constant, only nanoparticles of a given EMD pass the instrument and can be collected on corresponding supporting materials for subsequent nanoparticle analyses applying e.g. microscopic, immunologic or spectroscopic techniques. In our proof-of-concept study we now focus for the first time on mass spectrometric (MS) characterization of DMA size-selected material. We carried out size-selection of liposomes, vesicles consisting of a lipid bilayer and an aqueous lumen employed as carriers in e.g. pharmaceutic, cosmetic or nutritional applications. Particles of 85 nm EMD were collected on gold-coated silicon wafers. Subsequently, matrix was applied and Matrix-Assisted Laser Desorption / Ionization (MALDI) MS carried out. However, we not only focused on plain liposomes but also demonstrated the applicability of our approach for very heterogeneous low density lipoprotein (VLDL) particles, a transporter of lipid metabolism. Our novel offline hyphenation of gas-phase electrophoresis (termed nES DMA or nES GEMMA) and MALDI-MS opens the avenue to the molecular characterization of size-select nanoparticles of complex nature.
Collapse
|
8
|
Weiss VU, Wieland K, Schwaighofer A, Lendl B, Allmaier G. Native Nano-electrospray Differential Mobility Analyzer (nES GEMMA) Enables Size Selection of Liposomal Nanocarriers Combined with Subsequent Direct Spectroscopic Analysis. Anal Chem 2019; 91:3860-3868. [PMID: 30735037 PMCID: PMC6427476 DOI: 10.1021/acs.analchem.8b04252] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
![]()
Gas-phase
electrophoresis employing a nano-electrospray differential
mobility analyzer (nES DMA), aka gas-phase electrophoretic mobility
molecular analyzer (nES GEMMA), enables nanoparticle separation in
the gas-phase according to their surface-dry diameter with number-based
concentration detection. Moreover, particles in the nanometer
size range can be collected after size selection on supporting materials.
It has been shown by subsequent analyses employing orthogonal methods,
for instance, microscopic or antibody-based techniques, that the surface
integrity of collected analytes remains intact. Additionally, native
nES GEMMA demonstrated its applicability for liposome characterization.
Liposomes are nanometer-sized, biodegradable, and rather labile carriers
(nanoobjects) consisting of a lipid bilayer encapsulating an aqueous
lumen. In nutritional and pharmaceutical applications, these vesicles
allow shielded, targeted transport and sustained release of bioactive
cargo material. To date, cargo quantification is based on bulk measurements
after bilayer rupture. In this context, we now compare capillary electrophoresis
and spectroscopic characterization of vesicles in solution (bulk measurements)
to the possibility of spectroscopic investigation of individual, size-separated/collected
liposomes after nES GEMMA. Surface-dried, size-selected vesicles were
collected intact on calcium fluoride (CaF2) substrates
and zinc selenide (ZnSe) prisms, respectively, for subsequent spectroscopic
investigation. Our proof-of-principle study demonstrates that the
off-line hyphenation of gas-phase electrophoresis and confocal Raman
spectroscopy allows detection of isolated, nanometer-sized soft material/objects.
Additionally, atomic force microscopy-infrared spectroscopy (AFM-IR)
as an advanced spectroscopic system was employed to access molecule-specific
information with nanoscale lateral resolution. The off-line hyphenation
of nES GEMMA and AFM-IR is introduced to enable chemical imaging of
single, i.e., individual, liposome particles.
Collapse
Affiliation(s)
- Victor U Weiss
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| | - Karin Wieland
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| | - Andreas Schwaighofer
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| | - Bernhard Lendl
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| | - Guenter Allmaier
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| |
Collapse
|
9
|
Dit Fouque KJ, Moreno J, Hegemann JD, Zirah S, Rebuffat S, Fernandez-Lima F. Identification of Lasso Peptide Topologies Using Native Nanoelectrospray Ionization-Trapped Ion Mobility Spectrometry–Mass Spectrometry. Anal Chem 2018; 90:5139-5146. [DOI: 10.1021/acs.analchem.7b05230] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Kevin Jeanne Dit Fouque
- Department of Chemistry and Biochemistry, Florida International University, Miami, Florida 33199, United States
| | - Javier Moreno
- Department of Chemistry and Biochemistry, Florida International University, Miami, Florida 33199, United States
| | - Julian D. Hegemann
- Department of Chemistry, University of Illinois Urbana−Champaign, Urbana, Illinois 61801, United States
| | - Séverine Zirah
- Muséum National d’Histoire Naturelle, Laboratoire MCAM, Sorbonne Universités, 75005 Paris, France
| | - Sylvie Rebuffat
- Muséum National d’Histoire Naturelle, Laboratoire MCAM, Sorbonne Universités, 75005 Paris, France
| | - Francisco Fernandez-Lima
- Department of Chemistry and Biochemistry, Florida International University, Miami, Florida 33199, United States
| |
Collapse
|
10
|
Zheng X, Wojcik R, Zhang X, Ibrahim YM, Burnum-Johnson KE, Orton DJ, Monroe ME, Moore RJ, Smith RD, Baker ES. Coupling Front-End Separations, Ion Mobility Spectrometry, and Mass Spectrometry For Enhanced Multidimensional Biological and Environmental Analyses. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2017; 10:71-92. [PMID: 28301728 PMCID: PMC5627998 DOI: 10.1146/annurev-anchem-061516-045212] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. Though IMS alone is useful, its coupling with mass spectrometry (MS) and front-end separations is extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information available from biological and environmental sample analyses. In fact, multiple disease screening and environmental evaluations have illustrated that the IMS-based multidimensional separations extract information that cannot be acquired with each technique individually. This review highlights three-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography, supercritical fluid chromatography, liquid chromatography, solid-phase extractions, capillary electrophoresis, field asymmetric ion mobility spectrometry, and microfluidic devices. The origination, current state, various applications, and future capabilities of these multidimensional approaches are described in detail to provide insight into their uses and benefits.
Collapse
Affiliation(s)
- Xueyun Zheng
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Roza Wojcik
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Xing Zhang
- Skaggs School of Pharmacy and Pharmaceutical Sciences, Anschutz Medical Campus, University of Colorado, Denver, Colorado 80045
| | - Yehia M Ibrahim
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Kristin E Burnum-Johnson
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Daniel J Orton
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Matthew E Monroe
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Ronald J Moore
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Richard D Smith
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| | - Erin S Baker
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352;
| |
Collapse
|
11
|
Engel NY, Weiss VU, Marchetti-Deschmann M, Allmaier G. nES GEMMA Analysis of Lectins and Their Interactions with Glycoproteins - Separation, Detection, and Sampling of Noncovalent Biospecific Complexes. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:77-86. [PMID: 27644941 PMCID: PMC5174143 DOI: 10.1007/s13361-016-1483-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Revised: 07/24/2016] [Accepted: 08/13/2016] [Indexed: 06/06/2023]
Abstract
In order to better understand biological events, lectin-glycoprotein interactions are of interest. The possibility to gather more information than the mere positive or negative response for interactions brought mass spectrometry into the center of many research fields. The presented work shows the potential of a nano-electrospray gas-phase electrophoretic mobility molecular analyzer (nES GEMMA) to detect weak, noncovalent, biospecific interactions besides still unbound glycoproteins and unreacted lectins without prior liquid phase separation. First results for Sambucus nigra agglutinin, concanavalin A, and wheat germ agglutinin and their retained noncovalent interactions with glycoproteins in the gas phase are presented. Electrophoretic mobility diameters (EMDs) were obtained by nES GEMMA for all interaction partners correlating very well with molecular masses determined by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) of the individual molecules. Moreover, EMDs measured for the lectin-glycoprotein complexes were in good accordance with theoretically calculated mass values. Special focus was laid on complex formation for different lectin concentrations and binding specificities to evaluate the method with respect to results obtained in the liquid phase. The latter was addressed by capillary electrophoresis on-a-chip (CE-on-a-chip). Of exceptional interest was the fact that the formed complexes could be sampled according to their size onto nitrocellulose membranes after gas-phase separation. Subsequent immunological investigation further proved that the collected complex actually retained its native structure throughout nES GEMMA analysis and sampling. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Nicole Y Engel
- Institute of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Getreidemarkt 9/164-IAC, A-1060, Vienna, Austria
| | - Victor U Weiss
- Institute of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Getreidemarkt 9/164-IAC, A-1060, Vienna, Austria
| | - Martina Marchetti-Deschmann
- Institute of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Getreidemarkt 9/164-IAC, A-1060, Vienna, Austria
| | - Günter Allmaier
- Institute of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Getreidemarkt 9/164-IAC, A-1060, Vienna, Austria.
| |
Collapse
|
12
|
Benigni P, Marin R, Molano-Arevalo JC, Garabedian A, Wolff JJ, Ridgeway ME, Park MA, Fernandez-Lima F. Towards the Analysis of High Molecular Weight Proteins and Protein complexes using TIMS-MS. INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY : OFFICIAL PUBLICATION OF THE INTERNATIONAL SOCIETY FOR ION MOBILITY SPECTROMETRY 2016; 19:95-104. [PMID: 27818614 PMCID: PMC5091298 DOI: 10.1007/s12127-016-0201-8] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Revised: 05/26/2016] [Accepted: 05/29/2016] [Indexed: 01/02/2023]
Abstract
In the present work, we demonstrate the potential and versatility of TIMS for the analysis of proteins, DNA-protein complexes and protein-protein complexes in their native and denatured states. In addition, we show that accurate CCS measurement are possible and in good agreement with previously reported CCS values using other IMS analyzers (<5% difference). The main challenges for the analysis of high mass proteins and protein complexes in the mobility and m/z domain are described. That is, the analysis of high molecular weight systems in their native state may require the use of higher electric fields or a compromise in the TIMS mobility resolution by reducing the bath gas velocity in order to effectively trap at lower electric fields. This is the first report of CCS measurements of high molecular weight biomolecules and biomolecular complexes (~ 150 kDa) using TIMS-MS.
Collapse
Affiliation(s)
- Paolo Benigni
- Department of Chemistry & Biochemistry, Florida International University, Miami, FL 33199, USA
| | - Rebecca Marin
- Department of Chemistry & Biochemistry, Florida International University, Miami, FL 33199, USA
| | | | - Alyssa Garabedian
- Department of Chemistry & Biochemistry, Florida International University, Miami, FL 33199, USA
| | | | | | - Melvin A. Park
- Bruker Daltonics, Inc., Billerica, Massachusetts 01821, USA
| | - Francisco Fernandez-Lima
- Department of Chemistry & Biochemistry, Florida International University, Miami, FL 33199, USA
- Biomolecular Science Institute, Florida International University, Miami, FL 33199, USA
| |
Collapse
|
13
|
Cooper HJ. To What Extent is FAIMS Beneficial in the Analysis of Proteins? JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:566-77. [PMID: 26843211 PMCID: PMC4792363 DOI: 10.1007/s13361-015-1326-4] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 12/08/2015] [Accepted: 12/10/2015] [Indexed: 05/11/2023]
Abstract
High field asymmetric waveform ion mobility spectrometry (FAIMS), also known as differential ion mobility spectrometry, is emerging as a tool for biomolecular analysis. In this article, the benefits and limitations of FAIMS for protein analysis are discussed. The principles and mechanisms of FAIMS separation of ions are described, and the differences between FAIMS and conventional ion mobility spectrometry are detailed. Protein analysis is considered from both the top-down (intact proteins) and the bottom-up (proteolytic peptides) perspective. The roles of FAIMS in the analysis of complex mixtures of multiple intact proteins and in the analysis of multiple conformers of a single protein are assessed. Similarly, the application of FAIMS in proteomics and targeted analysis of peptides are considered.
Collapse
Affiliation(s)
- Helen J Cooper
- School of Biosciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK.
| |
Collapse
|
14
|
Silveira JA, Danielson W, Ridgeway ME, Park MA. Altering the mobility-time continuum: nonlinear scan functions for targeted high resolution trapped ion mobility-mass spectrometry. ACTA ACUST UNITED AC 2016. [DOI: 10.1007/s12127-016-0196-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
15
|
Ewing MA, Glover MS, Clemmer DE. Hybrid ion mobility and mass spectrometry as a separation tool. J Chromatogr A 2016; 1439:3-25. [DOI: 10.1016/j.chroma.2015.10.080] [Citation(s) in RCA: 73] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 10/05/2015] [Accepted: 10/21/2015] [Indexed: 11/29/2022]
|
16
|
Laszlo KJ, Bush MF. Analysis of Native-Like Proteins and Protein Complexes Using Cation to Anion Proton Transfer Reactions (CAPTR). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:2152-61. [PMID: 26323617 PMCID: PMC4655144 DOI: 10.1007/s13361-015-1245-4] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2015] [Revised: 07/23/2015] [Accepted: 08/01/2015] [Indexed: 05/08/2023]
Abstract
Mass spectra of native-like protein complexes often exhibit narrow charge-state distributions, broad peaks, and contributions from multiple, coexisting species. These factors can make it challenging to interpret those spectra, particularly for mixtures with significant heterogeneity. Here we demonstrate the use of ion/ion proton transfer reactions to reduce the charge states of m/z-selected, native-like ions of proteins and protein complexes, a technique that we refer to as cation to anion proton transfer reactions (CAPTR). We then demonstrate that CAPTR can increase the accuracy of charge state assignments and the resolution of interfering species in native mass spectrometry. The CAPTR product ion spectra for pyruvate kinase exhibit ~30 peaks and enable unambiguous determination of the charge state of each peak, whereas the corresponding precursor spectra exhibit ~6 peaks and the assigned charge states have an uncertainty of ±3%. 15+ bovine serum albumin and 21+ yeast enolase dimer both appear near m/z 4450 and are completely unresolved in a mixture. After a single CAPTR event, the resulting product ions are baseline resolved. The separation of the product ions increases dramatically after each subsequent CAPTR event; 12 events resulted in a 3000-fold improvement in separation relative to the precursor ions. Finally, we introduce a framework for interpreting and predicting the figures of merit for CAPTR experiments. More generally, these results suggest that CAPTR strongly complements other mass spectrometry tools for analyzing proteins and protein complexes, particularly those in mixtures. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Kenneth J Laszlo
- Department of Chemistry, University of Washington, Seattle, WA, 98195-1700, USA
| | - Matthew F Bush
- Department of Chemistry, University of Washington, Seattle, WA, 98195-1700, USA.
| |
Collapse
|
17
|
Fernandez de la Mora J. High-Resolution Mobility Analysis of Charge-Reduced Electrosprayed Protein Ions. Anal Chem 2015; 87:3729-35. [DOI: 10.1021/ac504445n] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Juan Fernandez de la Mora
- Department of Mechanical
Engineering and Materials Science, Yale University, New Haven, Connecticut 06520, United States
| |
Collapse
|
18
|
Affiliation(s)
- Jody C. May
- Department
of Chemistry,
Center for Innovative Technology, Vanderbilt Institute for Chemical
Biology, Vanderbilt Institute for Integrative Biosystems Research
and Education , Vanderbilt University, Nashville, Tennessee 37235, United States
| | - John A. McLean
- Department
of Chemistry,
Center for Innovative Technology, Vanderbilt Institute for Chemical
Biology, Vanderbilt Institute for Integrative Biosystems Research
and Education , Vanderbilt University, Nashville, Tennessee 37235, United States
| |
Collapse
|
19
|
Tseng YH, Pease LF. Electrospray differential mobility analysis for nanoscale medicinal and pharmaceutical applications. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2014; 10:1591-600. [PMID: 24846522 DOI: 10.1016/j.nano.2014.05.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2014] [Revised: 04/21/2014] [Accepted: 05/12/2014] [Indexed: 12/14/2022]
Abstract
Nanoscale characterization tools hold the potential to overcome long-standing medicinal and pharmaceutical challenges. For example, electrospray differential mobility analysis (ES-DMA) is an emerging tool that rapidly provides label-free multimodal size distributions for proteins and particles from ~1 nm to <500 nm with subnanometer precision. Here we critically review the contributions of this tool to medicine, pharmaceutical practice, and pharmaceutical production. Our review critically evaluates, first, the use of ES-DMA for diagnostic strategies that detect and quantify lipoproteins, bacterial infections, viruses and amyloid fibrillation and then focuses on ES-DMA's contribution to treatment strategies that employ tailored virus-like particles as vaccines and decorated nanoparticle vectors for gene delivery. Our review also highlights ES-DMA's contribution to viral clearance and antibody aggregation and potential as a process analytical technology (PAT). FROM THE CLINICAL EDITOR Electrospray differential mobility analysis is an emerging nanotechnology-based tool with potential clinical utility in the detection and quantification of lipoproteins, glycoproteins, viruses, amyloids, bacterial infections. Its contribution to treatment strategies and pharmaceutical production is also discussed in this comprehensive review.
Collapse
Affiliation(s)
- Yen-Hsun Tseng
- Department of Chemical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Leonard F Pease
- Department of Chemical Engineering, University of Utah, Salt Lake City, UT, USA; Department of Internal Medicine, Division of Gastroenterology, University of Utah, Salt Lake City, UT, USA; Department of Pharmaceutics & Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT, USA.
| |
Collapse
|
20
|
Mui W, Thomas DA, Downard AJ, Beauchamp JL, Seinfeld JH, Flagan RC. Ion Mobility-Mass Spectrometry with a Radial Opposed Migration Ion and Aerosol Classifier (ROMIAC). Anal Chem 2013; 85:6319-26. [DOI: 10.1021/ac400580u] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Wilton Mui
- Division of Engineering
and
Applied Science, California Institute of Technology, Pasadena, California 91125, United States
| | - Daniel A. Thomas
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Andrew J. Downard
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Jesse L. Beauchamp
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - John H. Seinfeld
- Division of Engineering
and
Applied Science, California Institute of Technology, Pasadena, California 91125, United States
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Richard C. Flagan
- Division of Engineering
and
Applied Science, California Institute of Technology, Pasadena, California 91125, United States
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| |
Collapse
|
21
|
Pessôa GDS, Pilau EJ, Gozzo FC, Arruda MAZ. Ion mobility spectrometry focusing on speciation analysis of metals/metalloids bound to carbonic anhydrase. Anal Bioanal Chem 2013; 405:7653-60. [PMID: 23722891 DOI: 10.1007/s00216-013-7064-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2013] [Revised: 05/07/2013] [Accepted: 05/10/2013] [Indexed: 11/26/2022]
Abstract
In the present work, traveling wave ion mobility spectrometry-mass spectrometry (TWIMS-MS) was applied to speciation analysis of metalloproteins. The influence of pH on complexation conditions between some metals and bovine carbonic anhydrase was evaluated from pH 6 to 9, as well as the time involved in their complexation (0-24 h). Employing TWIMS-MS, two conformational states of bovine carbonic anhydrase were observed with charge states of +12 and +11; these configurations being evaluated in terms of the folded state of the apo form and this protein (at charge state +11) being linked to barium, lead, copper, and zinc in their divalent forms. Metalloprotein speciation analysis was carried out for copper (Cu(+) and Cu(2+)), lead (Pb(2+) and Pb(4+)), and selenium (Se(4+) and Se(6+)) species complexed with bovine carbonic anhydrase. Mobilities of all complexed species were compared, also considering the apo form of this protein.
Collapse
Affiliation(s)
- Gustavo de Souza Pessôa
- Spectrometry, Sample Preparation and Mechanization Group, GEPAM, Institute of Chemistry, University of Campinas-UNICAMP, P.O. Box 6154, Campinas, SP, 13083-970, Brazil
| | | | | | | |
Collapse
|
22
|
Lapthorn C, Pullen F, Chowdhry BZ. Ion mobility spectrometry-mass spectrometry (IMS-MS) of small molecules: separating and assigning structures to ions. MASS SPECTROMETRY REVIEWS 2013; 32:43-71. [PMID: 22941854 DOI: 10.1002/mas.21349] [Citation(s) in RCA: 183] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2011] [Revised: 01/29/2012] [Accepted: 03/08/2012] [Indexed: 05/11/2023]
Abstract
The phenomenon of ion mobility (IM), the movement/transport of charged particles under the influence of an electric field, was first observed in the early 20th Century and harnessed later in ion mobility spectrometry (IMS). There have been rapid advances in instrumental design, experimental methods, and theory together with contributions from computational chemistry and gas-phase ion chemistry, which have diversified the range of potential applications of contemporary IMS techniques. Whilst IMS-mass spectrometry (IMS-MS) has recently been recognized for having significant research/applied industrial potential and encompasses multi-/cross-disciplinary areas of science, the applications and impact from decades of research are only now beginning to be utilized for "small molecule" species. This review focuses on the application of IMS-MS to "small molecule" species typically used in drug discovery (100-500 Da) including an assessment of the limitations and possibilities of the technique. Potential future developments in instrumental design, experimental methods, and applications are addressed. The typical application of IMS-MS in relation to small molecules has been to separate species in fairly uniform molecular classes such as mixture analysis, including metabolites. Separation of similar species has historically been challenging using IMS as the resolving power, R, has been low (3-100) and the differences in collision cross-sections that could be measured have been relatively small, so instrument and method development has often focused on increasing resolving power. However, IMS-MS has a range of other potential applications that are examined in this review where it displays unique advantages, including: determination of small molecule structure from drift time, "small molecule" separation in achiral and chiral mixtures, improvement in selectivity, identification of carbohydrate isomers, metabonomics, and for understanding the size and shape of small molecules. This review provides a broad but selective overview of current literature, concentrating on IMS-MS, not solely IMS, and small molecule applications.
Collapse
Affiliation(s)
- Cris Lapthorn
- School of Science, University of Greenwich, Medway Campus, Chatham, Kent ME4 4TB, UK
| | | | | |
Collapse
|
23
|
Blake RC, Blake DA. Electrospray ionization-ion mobility spectrometry identified monoclonal antibodies that bind exclusively to either the monomeric or a dimeric form of prostate specific antigen. Anal Chem 2012; 84:6899-906. [PMID: 22827589 PMCID: PMC3413244 DOI: 10.1021/ac301527v] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
![]()
Macroion mobility spectrometry was used to distinguish
between
a monoclonal antibody (clone M612165) that bound exclusively to monomeric
prostate specific antigen and a different monoclonal antibody (clone
M612166) that bound exclusively to a dimeric form of the antigen that
only comprised 6.8% of the total protein. In the presence of excess
antigen, the mobility spectrum of M612165 was replaced by a composite
spectrum that represented a mixture of antibodies that included either
one or two equivalents of the protein antigen. In similar circumstances,
the mobility spectrum of M612166 was replaced by a composite spectrum
that represented a mixture of antibodies that included either two
or four equivalents of the protein antigen. When exposed to either
of the two antibodies, the mobility spectrum of the prostate specific
antigen showed a concomitant decrease in the monomeric antigen in
one case and in the dimeric antigen in the other case. While sensitive
kinetic exclusion assays demonstrated large differences in the antigen
binding behavior of the two antibodies, these functional studies alone
were insufficient to reveal the likely structural origins of the observed
differences. Macroion mobility measurements were shown to be a useful
and informative complement to functional studies in understanding
complex macromolecular interactions.
Collapse
Affiliation(s)
- Robert C Blake
- Division of Basic Pharmaceutical Sciences, College of Pharmacy, Xavier University of Louisiana, New Orleans, Louisiana 70125, USA.
| | | |
Collapse
|
24
|
Kliman M, May JC, McLean JA. Lipid analysis and lipidomics by structurally selective ion mobility-mass spectrometry. BIOCHIMICA ET BIOPHYSICA ACTA 2011; 1811:935-45. [PMID: 21708282 PMCID: PMC3326421 DOI: 10.1016/j.bbalip.2011.05.016] [Citation(s) in RCA: 143] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2011] [Revised: 05/20/2011] [Accepted: 05/23/2011] [Indexed: 01/08/2023]
Abstract
Recent advances in mass spectrometry approaches to the analysis of lipids include the ability to incorporate both lipid class identification with lipid structural information for increased characterization capabilities. The detailed examination of lipids and their biosynthetic and biochemical pathways made possible by novel instrumental and bioinformatics approaches is advancing research in fundamental cellular and medical studies. Recently, high-throughput structural analysis has been demonstrated through the use of rapid gas-phase separation on the basis of the ion mobility (IM) analytical technique combined with mass spectrometry (IM-MS). While IM-MS has been extensively utilized in biochemical research for peptide, protein and small molecule analysis, the role of IM-MS in lipid research is still an active area of development. In this review of lipid-based IM-MS research, we begin with an overview of three contemporary IM techniques which show great promise in being applied towards the analysis of lipids. Fundamental concepts regarding the integration of IM-MS are reviewed with emphasis on the applications of IM-MS towards simplifying and enhancing complex biological sample analysis. Finally, several recent IM-MS lipid studies are highlighted and the future prospects of IM-MS for integrated omics studies and enhanced spatial profiling through imaging IM-MS are briefly described.
Collapse
|
25
|
Using nanoelectrospray ion mobility spectrometry (GEMMA) to determine the size and relative molecular mass of proteins and protein assemblies: a comparison with MALLS and QELS. Anal Bioanal Chem 2011; 399:2421-33. [PMID: 21234551 DOI: 10.1007/s00216-010-4634-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2010] [Revised: 12/17/2010] [Accepted: 12/20/2010] [Indexed: 02/06/2023]
Abstract
The determination of protein assembly size and relative molecular mass is currently of great importance in biochemical analysis. In particular, the technique of nanoelectrospray (nES) with a gas-phase electrophoretic mobility molecular analyzer (GEMMA) has received increased attention for such measurements. However, in order for the GEMMA technique to gain broader acceptance in protein analysis, it must be further evaluated and compared with other established bioanalytical techniques. In the present study, nES-GEMMA was evaluated for the analysis of a set of protein and protein complexes involved in the Sec and the bacterial type III secretion pathway of enteropathogenic Escherichia coli bacteria. The same set of proteins, isolated and purified using standard biochemical protocols, were also analyzed using multi-angle laser light scattering (MALLS) and quasi-elastic light scattering (QELS), following size exclusion chromatography. This allowed for direct comparisons between the three techniques. It was found that nES-GEMMA, in comparison to the more established MALLS and QELS techniques, offers several complementary advantages. It requires considerably less amount of material, i.e., nanogram vs. milligram amounts, and time per sample analysis, i.e., few minutes vs. tens of minutes. Whereas the determined size and relative molecular mass are similar between the compared methods, the electrophoretic diameters determined using nES-GEMMA seem to be systematically smaller compared to the hydrodynamic diameter derived by QELS. Some of the GEMMA technique disadvantages include its narrow dynamic range, limited by the fact that at elevated protein concentrations there is increased potential for the occurrence of nES-induced oligomers. Thus, it is preferred to analyze dilute protein solutions because non-specific oligomers are less likely to occur whereas biospecific oligomers remain detected. To further understand the formation of nES-oligomers, the effect of buffer concentration on their formation was evaluated. Also, nES-GEMMA is not compatible with all the buffers commonly used with MALLS and QELS. Overall, however, the nES-GEMMA technique shows promise as a high-throughput proteomics/protein structure tool.
Collapse
|
26
|
Hogan CJ, de la Mora JF. Ion mobility measurements of nondenatured 12-150 kDa proteins and protein multimers by tandem differential mobility analysis-mass spectrometry (DMA-MS). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2011; 22:158-172. [PMID: 21472554 DOI: 10.1007/s13361-010-0014-7] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2010] [Revised: 10/04/2010] [Accepted: 10/06/2010] [Indexed: 05/30/2023]
Abstract
The mobilities of electrosprayed proteins and protein multimers with molecular weights ranging from 12.4 kDa (cytochrome C monomers) to 154 kDa (nonspecific concanavalin A hexamers) were measured in dry air by a planar differential mobility analyzer (DMA) coupled to a time-of-flight mass spectrometer (TOF-MS). The DMA determines true mobility at atmospheric pressure, without perturbing ion structure from that delivered by the electrospray. A nondenaturing aqueous 20 mM triethylammonium formate buffer yields compact ions with low charge states, moderating polarization effects on ion mobility. Conversion of mobilities into cross-sections involves a reduction factor ξ for the actual mobility relative to that associated with elastic specular collisions with smooth surfaces. ξ is known to be 1.36 in air from Millikan's oil drop experiments. A similar enhancement effect ascribed to atomic-scale surface roughness has been found in numerical simulations. Adopting Millikan's value ξ=1.36 and assuming a spherical geometry yields a gas-phase protein density ρ(p)=0.949±0.053 g cm(-3) for all our protein data. This is substantially higher than the 0.67 g cm(-3) found in recent low-resolution DMA measurements of singly charged proteins. DMA-MS can distinguish nonspecific protein aggregates formed during the electrospray process from those formed preferentially in solution. The observed charge versus diameter relation is compatible with a protein charge reduction mechanism based on the evaporation of triethylammonium ions from electrosprayed drops.
Collapse
|
27
|
Hogan Jr. CJ, Ogorzalek Loo RR, Loo JA, Mora JFDL. Ion mobility–mass spectrometry of phosphorylase B ions generated with supercharging reagents but in charge-reducing buffer. Phys Chem Chem Phys 2010; 12:13476-83. [DOI: 10.1039/c0cp01208d] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
28
|
Adou K, Johnston MV. Flow interface for charge-reduced electrospray of nanoparticle solutions. Anal Chem 2009; 81:10186-92. [PMID: 19924869 DOI: 10.1021/ac902275h] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A charge reduction (CR) interface for electrospray ionization that permits simultaneous analysis of nanoparticle solutions by multiple detection methods was characterized. In the direct infusion configuration, a constant flow of analyte solution undergoes electrospray ionization (ESI). The charged aerosol is sampled directly into the atmospheric pressure inlet of a quadrupole time-of-flight mass spectrometer and into a CR device followed by a differential mobility analyzer (DMA) and condensation particle counter (CPC). In the plug injection configuration, analyte solution is injected into a liquid chromatograph. The effluent is split to an evaporative light scattering detector (ELSD) and the ESI interface. The charged aerosol is then sampled through the CR device directly into the CPC. Performance characteristics of the two configurations were studied with sucrose and protein solutions. When a liquid flow rate in the low microliter per minute range was used, the reconstructed droplet size distribution from the ESI interface had an average diameter of 184 nm with a geometric standard deviation of 1.4. For the first configuration, the linear working range was wider for ESI-MS than the CR device-DMA-CPC. For the second configuration, the detection efficiency, defined as the fraction of molecules flowing through the ESI interface that are ultimately detected by the CPC, was on the order of 10(-6). Simultaneous measurements with the ELSD and CPC were consistent with analyte molecular size and may provide a means of estimating the size of unknown particles.
Collapse
Affiliation(s)
- Kouame Adou
- Department of Chemistry & Biochemistry, University of Delaware, Newark, Delaware 19716, USA
| | | |
Collapse
|
29
|
Baykut G, von Halem O, Raether O. Applying a dynamic method to the measurement of ion mobility. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2009; 20:2070-2081. [PMID: 19713123 DOI: 10.1016/j.jasms.2009.07.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2009] [Revised: 07/16/2009] [Accepted: 07/16/2009] [Indexed: 05/28/2023]
Abstract
A dynamic method is applied to measure the mobility of gas-phase ions in the dual ion funnel interface of the electrospray source of a quadrupole orthogonal time-of-flight mass spectrometer. In a new operational mode, a potential barrier was formed in the second ion funnel of the mass spectrometer and then progressively increased. In this region, a flow of gas drags the ions into the mass spectrometer while the electric force applied by the potential barrier decelerates them. Ions with lower mobility can be carried by the gas flow more easily than those with high mobility. Thus, electrical forces can block the more mobile ions more easily. Hence, the electric barrier formed in the ion funnel permits only ions below a certain mobility threshold to enter the mass spectrometer. When the barrier voltage is increased, this threshold moves from high to low mobilities. Ions with mobilities above the threshold cannot enter the mass spectrometer, and their signal decreases to zero. Thus, in a barrier voltage scan, mass spectrometric signals of ions sequentially disappear. Differentiation of these decreasing ion signal curves produces peaks from which an ion mobility spectrum can be reconstructed. Blocking voltages, i.e., the positions of the peaks on the barrier voltage scale are directly related to the mobility of these ions. An internal calibration using ions with known mobility values helps determine the unknown ion mobilities and allows calculation of ionic cross sections.
Collapse
|
30
|
Pendular proteins in gases and new avenues for characterization of macromolecules by ion mobility spectrometry. Proc Natl Acad Sci U S A 2009; 106:6495-500. [PMID: 19351899 DOI: 10.1073/pnas.0812318106] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Polar molecules align in electric fields when the dipole energy (proportional to field intensity E x dipole moment p) exceeds the thermal rotational energy. Small molecules have low p and align only at inordinately high E or upon extreme cooling. Many biomacromolecules and ions are strong permanent dipoles that align at E achievable in gases and room temperature. The collision cross-sections of aligned ions with gas molecules generally differ from orientationally averaged quantities, affecting ion mobilities measured in ion mobility spectrometry (IMS). Field asymmetric waveform IMS (FAIMS) separates ions by the difference between mobilities at high and low E and hence can resolve and identify macroion conformers based on the mobility difference between pendular and free rotor states. The exceptional sensitivity of that difference to ion geometry and charge distribution holds the potential for a powerful method for separation and characterization of macromolecular species. Theory predicts that the pendular alignment of ions in gases at any E requires a minimum p that depends on the ion mobility, gas pressure, and temperature. At ambient conditions used in current FAIMS systems, p for realistic ions must exceed approximately 300-400 Debye. The dipole moments of proteins statistically increase with increasing mass, and such values are typical above approximately 30 kDa. As expected for the dipole-aligned regime, FAIMS analyses of protein ions and complexes of approximately 30-130 kDa show an order-of-magnitude expansion of separation space compared with smaller proteins and other ions.
Collapse
|
31
|
Hogan Jr CJ, Fernández de la Mora J. Tandem ion mobility-mass spectrometry (IMS-MS) study of ion evaporation from ionic liquid-acetonitrile nanodrops. Phys Chem Chem Phys 2009; 11:8079-90. [DOI: 10.1039/b904022f] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
32
|
Abstract
Traveling wave ion mobility spectrometry (TW IMS) is a new IMS method implemented in the Synapt IMS/mass spectrometry system (Waters). Despite its wide adoption, the foundations of TW IMS were only qualitatively understood and factors governing the ion transit time (the separation parameter) and resolution remained murky. Here we develop the theory of TW IMS using derivations and ion dynamics simulations. The key parameter is the ratio (c) of ion drift velocity at the steepest wave slope to wave speed. At low c, the ion transit velocity is proportional to the squares of mobility (K) and electric field intensity (E), as opposed to linear scaling in drift tube (DT) IMS and differential mobility analyzers. At higher c, the scaling deviates from quadratic in a way controlled by the waveform profile, becoming more gradual with the ideal triangular profile but first steeper and then more gradual for realistic profiles with variable E. At highest c, the transit velocity asymptotically approaches the wave speed. Unlike with DT IMS, the resolving power of TW IMS depends on mobility, scaling as K(1/2) in the low-c limit and less at higher c. A nonlinear dependence of the transit time on mobility means that the true resolving power of TW IMS differs from that indicated by the spectrum. A near-optimum resolution is achievable over an approximately 300-400% range of mobilities. The major predicted trends are in agreement with TW IMS measurements for peptide ions as a function of mobility, wave amplitude, and gas pressure. The issues of proper TW IMS calibration and ion distortion by field heating are also discussed. The new quantitative understanding of TW IMS separations allows rational optimization of instrument design and operation and improved spectral calibration.
Collapse
Affiliation(s)
- Alexandre A Shvartsburg
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, USA
| | | |
Collapse
|
33
|
Clowers BH, Ibrahim YM, Prior DC, Danielson WF, Belov ME, Smith RD. Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry. Anal Chem 2008; 80:612-23. [PMID: 18166021 DOI: 10.1021/ac701648p] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Conventional ion mobility spectrometers that sample ion packets from continuous sources have traditionally been constrained by an inherently low duty cycle. As such, ion utilization efficiencies have been limited to <1% in order to maintain instrumental resolving power. Using a modified electrodynamic ion funnel, we demonstrated the ability to accumulate, store, and eject ions in conjunction with ion mobility spectrometry (IMS), which elevated the charge density of the ion packets ejected from the ion funnel trap (IFT) and provided a considerable increase in the overall ion utilization efficiency of the IMS instrument. A 7-fold increase in signal intensity was revealed by comparing continuous ion beam current with the amplitude of the pulsed ion current in IFT-IMS experiments using a Faraday plate. Additionally, we describe the IFT operating characteristics using a time-of-flight mass spectrometer attached to the IMS drift tube.
Collapse
Affiliation(s)
- Brian H Clowers
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA
| | | | | | | | | | | |
Collapse
|
34
|
Kaddis CS, Lomeli SH, Yin S, Berhane B, Apostol MI, Kickhoefer VA, Rome LH, Loo JA. Sizing large proteins and protein complexes by electrospray ionization mass spectrometry and ion mobility. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2007; 18:1206-16. [PMID: 17434746 PMCID: PMC2680693 DOI: 10.1016/j.jasms.2007.02.015] [Citation(s) in RCA: 92] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2006] [Revised: 02/26/2007] [Accepted: 02/26/2007] [Indexed: 05/09/2023]
Abstract
Mass spectrometry (MS) and ion mobility with electrospray ionization (ESI) have the capability to measure and detect large noncovalent protein-ligand and protein-protein complexes. Using an ion mobility method of gas-phase electrophoretic mobility molecular analysis (GEMMA), protein particles representing a range of sizes can be separated by their electrophoretic mobility in air. Highly charged particles produced from a protein complex solution using electrospray can be manipulated to produce singly charged ions, which can be separated and quantified by their electrophoretic mobility. Results from ESI-GEMMA analysis from our laboratory and others were compared with other experimental and theoretically determined parameters, such as molecular mass and cryoelectron microscopy and X-ray crystal structure dimensions. There is a strong correlation between the electrophoretic mobility diameter determined from GEMMA analysis and the molecular mass for protein complexes up to 12 MDa, including the 93 kDa enolase dimer, the 480 kDa ferritin 24-mer complex, the 4.6 MDa cowpea chlorotic mottle virus (CCMV), and the 9 MDa MVP-vault assembly. ESI-GEMMA is used to differentiate a number of similarly sized vault complexes that are composed of different N-terminal protein tags on the MVP subunit. The average effective density of the proteins and protein complexes studied was 0.6 g/cm(3). Moreover, there is evidence that proteins and protein complexes collapse or become more compact in the gas phase in the absence of water.
Collapse
Affiliation(s)
- Catherine S. Kaddis
- Department of Chemistry and Biochemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095
| | - Shirley H. Lomeli
- Department of Chemistry and Biochemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095
| | - Sheng Yin
- Department of Chemistry and Biochemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095
| | - Beniam Berhane
- Department of Chemistry and Biochemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095
| | - Marcin I. Apostol
- Department of Chemistry and Biochemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095
| | - Valerie A. Kickhoefer
- Department of Biological Chemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095
| | - Leonard H. Rome
- Department of Biological Chemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095
| | - Joseph A. Loo
- Department of Chemistry and Biochemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095
- Department of Biological Chemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095
- To whom correspondence should be addressed. E-mail: , Phone: (310) 794-7023, Fax: (310) 206-4038
| |
Collapse
|