1
|
Graf T, Naumann L, Bonnington L, Heckel J, Spensberger B, Klein S, Brey C, Nachtigall R, Mroz M, Hogg TV, McHardy C, Martinez A, Braaz R, Leiss M. Expediting online liquid chromatography for real-time monitoring of product attributes to advance process analytical technology in downstream processing of biopharmaceuticals. J Chromatogr A 2024; 1729:465013. [PMID: 38824753 DOI: 10.1016/j.chroma.2024.465013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 05/16/2024] [Accepted: 05/20/2024] [Indexed: 06/04/2024]
Abstract
The application of Process Analytical Technology (PAT) principles for manufacturing of biotherapeutics proffers the prospect of ensuring consistent product quality along with increased productivity as well as substantial cost and time savings. Although this paradigm shift from a traditional, rather rigid manufacturing model to a more scientific, risk-based approach has been advocated by health authorities for almost two decades, the practical implementation of PAT in the biopharmaceutical industry is still limited by the lack of fit-for-purpose analytical methods. In this regard, most of the proposed spectroscopic techniques are sufficiently fast but exhibit deficiencies in terms of selectivity and sensitivity, while well-established offline methods, such as (ultra-)high-performance liquid chromatography, are generally considered as too slow for this task. To address these reservations, we introduce here a novel online Liquid Chromatography (LC) setup that was specifically designed to enable real-time monitoring of critical product quality attributes during time-sensitive purification operations in downstream processing. Using this online LC solution in combination with fast, purpose-built analytical methods, sampling cycle times between 1.30 and 2.35 min were achieved, without compromising on the ability to resolve and quantify the product variants of interest. The capabilities of our approach are ultimately assessed in three case studies, involving various biotherapeutic modalities, downstream processes and analytical chromatographic separation modes. Altogether, our results highlight the expansive opportunities of online LC based applications to serve as a PAT tool for biopharmaceutical manufacturing.
Collapse
Affiliation(s)
- Tobias Graf
- Pharma Technical Development Analytics, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Lukas Naumann
- Pharma Technical Development Analytics, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Lea Bonnington
- Pharma Technical Development Analytics, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Jakob Heckel
- Pharma Technical Development Analytics, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Bernhard Spensberger
- Pharma Research and Early Development (pRED), Roche Innovation Center Munich, Roche Diagnostics GmbH, Nonnenwald 2, 82377 Penzberg, Germany
| | - Sascha Klein
- Pharma Technical Development Bioprocessing, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Christoph Brey
- Pharma Technical Development Bioprocessing, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Ronnie Nachtigall
- Pharma Technical Development Bioprocessing, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Maximilian Mroz
- Pharma Technical Development Bioprocessing, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Thomas Vagn Hogg
- Pharma Research and Early Development (pRED), Roche Innovation Center Munich, Roche Diagnostics GmbH, Nonnenwald 2, 82377 Penzberg, Germany
| | - Christopher McHardy
- Pharma Technical Development Bioprocessing, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Andrés Martinez
- Gene Therapy Technical Development, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Reinhard Braaz
- Pharma Technical Development Clinical Supply Center, Roche Diagnostics GmbH, 82377 Penzberg, Germany
| | - Michael Leiss
- Pharma Technical Development Analytics, Roche Diagnostics GmbH, 82377 Penzberg, Germany.
| |
Collapse
|
2
|
Zhang Z, Lang Z, Chen G, Zhou H, Zhou W. Development of generic metabolic Raman calibration models using solution titration in aqueous phase and data augmentation for in-line cell culture analysis. Biotechnol Bioeng 2024; 121:2193-2204. [PMID: 38639160 DOI: 10.1002/bit.28717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 02/29/2024] [Accepted: 04/08/2024] [Indexed: 04/20/2024]
Abstract
This study presents a novel approach for developing generic metabolic Raman calibration models for in-line cell culture analysis using glucose and lactate stock solution titration in an aqueous phase and data augmentation techniques. First, a successful set-up of the titration method was achieved by adding glucose or lactate solution at several different constant rates into the aqueous phase of a bench-top bioreactor. Subsequently, the in-line glucose and lactate concentration were calculated and interpolated based on the rate of glucose and lactate addition, enabling data augmentation and enhancing the robustness of the metabolic calibration model. Nine different combinations of spectra pretreatment, wavenumber range selection, and number of latent variables were evaluated and optimized using aqueous titration data as training set and a historical cell culture data set as validation and prediction set. Finally, Raman spectroscopy data collected from 11 historical cell culture batches (spanning four culture modes and scales ranging from 3 to 200 L) were utilized to predict the corresponding glucose and lactate values. The results demonstrated a high prediction accuracy, with an average root mean square errors of prediction of 0.65 g/L for glucose, and 0.48 g/L for lactate. This innovative method establishes a generic metabolic calibration model, and its applicability can be extended to other metabolites, reducing the cost of deploying real-time cell culture monitoring using Raman spectroscopy in bioprocesses.
Collapse
Affiliation(s)
- Zhijun Zhang
- Cell Culture Process Development (CCPD), WuXi Biologics, Shanghai, China
| | - Zhe Lang
- Cell Culture Process Development (CCPD), WuXi Biologics, Shanghai, China
| | - Gong Chen
- Cell Culture Process Development (CCPD), WuXi Biologics, Shanghai, China
| | - Hang Zhou
- Cell Culture Process Development (CCPD), WuXi Biologics, Shanghai, China
| | - Weichang Zhou
- Global Biologics Development and Operations (GBDO), WuXi Biologics, Shanghai, China
| |
Collapse
|
3
|
Sripada SA, Hosseini M, Ramesh S, Wang J, Ritola K, Menegatti S, Daniele MA. Advances and opportunities in process analytical technologies for viral vector manufacturing. Biotechnol Adv 2024; 74:108391. [PMID: 38848795 DOI: 10.1016/j.biotechadv.2024.108391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 03/14/2024] [Accepted: 05/29/2024] [Indexed: 06/09/2024]
Abstract
Viral vectors are an emerging, exciting class of biologics whose application in vaccines, oncology, and gene therapy has grown exponentially in recent years. Following first regulatory approval, this class of therapeutics has been vigorously pursued to treat monogenic disorders including orphan diseases, entering hundreds of new products into pipelines. Viral vector manufacturing supporting clinical efforts has spurred the introduction of a broad swath of analytical techniques dedicated to assessing the diverse and evolving panel of Critical Quality Attributes (CQAs) of these products. Herein, we provide an overview of the current state of analytics enabling measurement of CQAs such as capsid and vector identities, product titer, transduction efficiency, impurity clearance etc. We highlight orthogonal methods and discuss the advantages and limitations of these techniques while evaluating their adaptation as process analytical technologies. Finally, we identify gaps and propose opportunities in enabling existing technologies for real-time monitoring from hardware, software, and data analysis viewpoints for technology development within viral vector biomanufacturing.
Collapse
Affiliation(s)
- Sobhana A Sripada
- Department of Chemical and Biomolecular Engineering, North Carolina State University, 911 Partners Way, Raleigh, NC, 27695, USA
| | - Mahshid Hosseini
- Joint Department of Biomedical Engineering, North Carolina State University, and University of North Carolina, Chapel Hill, 911 Oval Dr., Raleigh, NC 27695, USA
| | - Srivatsan Ramesh
- Department of Chemical and Biomolecular Engineering, North Carolina State University, 911 Partners Way, Raleigh, NC, 27695, USA
| | - Junhyeong Wang
- Joint Department of Biomedical Engineering, North Carolina State University, and University of North Carolina, Chapel Hill, 911 Oval Dr., Raleigh, NC 27695, USA
| | - Kimberly Ritola
- North Carolina Viral Vector Initiative in Research and Learning (NC-VVIRAL), North Carolina State University, 890 Oval Dr, Raleigh, NC 27695, USA; Neuroscience Center, Brain Initiative Neurotools Vector Core, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Stefano Menegatti
- Department of Chemical and Biomolecular Engineering, North Carolina State University, 911 Partners Way, Raleigh, NC, 27695, USA; North Carolina Viral Vector Initiative in Research and Learning (NC-VVIRAL), North Carolina State University, 890 Oval Dr, Raleigh, NC 27695, USA; Biomanufacturing Training and Education Center, North Carolina State University, 890 Main Campus Dr, Raleigh, NC 27695, USA.
| | - Michael A Daniele
- Joint Department of Biomedical Engineering, North Carolina State University, and University of North Carolina, Chapel Hill, 911 Oval Dr., Raleigh, NC 27695, USA; North Carolina Viral Vector Initiative in Research and Learning (NC-VVIRAL), North Carolina State University, 890 Oval Dr, Raleigh, NC 27695, USA; Department of Electrical and Computer Engineering, North Carolina State University, 890 Oval Dr, Raleigh, NC 27695, USA.
| |
Collapse
|
4
|
Wan B, Patel M, Zhou G, Olma M, Bieri M, Mueller M, Appiah-Amponsah E, Patel B, Jayapal K. Robust platform for inline Raman monitoring and control of perfusion cell culture. Biotechnol Bioeng 2024; 121:1688-1701. [PMID: 38393313 DOI: 10.1002/bit.28680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 01/23/2024] [Accepted: 02/12/2024] [Indexed: 02/25/2024]
Abstract
Perfusion cell culture has been gaining increasing popularity for biologics manufacturing due to benefits such as smaller footprint, increased productivity, consistent product quality and manufacturing flexibility, cost savings, and so forth. Process Analytics Technologies tools are highly desirable for effective monitoring and control of long-running perfusion processes. Raman has been widely investigated for monitoring and control of traditional fed batch cell culture process. However, implementation of Raman for perfusion cell culture has been very limited mainly due to challenges with high-cell density and long running times during perfusion which cause extremely high fluorescence interference to Raman spectra and consequently it is exceedingly difficult to develop robust chemometrics models. In this work, a platform based on Raman measurement of permeate has been proposed for effective analysis of perfusion process. It has been demonstrated that this platform can effectively circumvent the fluorescence interference issue while providing rich and timely information about perfusion dynamics to enable efficient process monitoring and robust bioreactor feed control. With the highly consistent spectral data from cell-free sample matrix, development of chemometrics models can be greatly facilitated. Based on this platform, Raman models have been developed for good measurement of several analytes including glucose, lactate, glutamine, glutamate, and permeate titer. Performance of Raman models developed this way has been systematically evaluated and the models have shown good robustness against changes in perfusion scale and variations in permeate flowrate; thus models developed from small lab scale can be directly transferred for implementation in much larger scale of perfusion. With demonstrated robustness, this platform provides a reliable approach for automated glucose feed control in perfusion bioreactors. Glucose model developed from small lab scale has been successfully implemented for automated continuous glucose feed control of perfusion cell culture at much larger scale.
Collapse
Affiliation(s)
- Boyong Wan
- Analytical Research & Development, Merck & Co. Inc., Kenilworth, New Jersey, USA
| | - Misaal Patel
- Bioprocess Research & Development, Merck & Co. Inc., Kenilworth, New Jersey, USA
| | - George Zhou
- Global Vaccine and Biologics Commercialization, Merck & Co. Inc., Kenilworth, New Jersey, USA
| | - Michael Olma
- Analytical Research & Development, Werthenstein Biopharma GmbH, MSD, Werthenstein, Switzerland
| | - Marco Bieri
- Analytical Research & Development, Werthenstein Biopharma GmbH, MSD, Werthenstein, Switzerland
| | - Marvin Mueller
- Analytical Research & Development, Werthenstein Biopharma GmbH, MSD, Werthenstein, Switzerland
| | | | - Bhumit Patel
- Analytical Research & Development, Merck & Co. Inc., Kenilworth, New Jersey, USA
| | - Karthik Jayapal
- Bioprocess Research & Development, Merck & Co. Inc., Kenilworth, New Jersey, USA
| |
Collapse
|
5
|
Wang J, Chen J, Studts J, Wang G. Simultaneous prediction of 16 quality attributes during protein A chromatography using machine learning based Raman spectroscopy models. Biotechnol Bioeng 2024; 121:1729-1738. [PMID: 38419489 DOI: 10.1002/bit.28679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 01/29/2024] [Accepted: 02/10/2024] [Indexed: 03/02/2024]
Abstract
Several key technologies for advancing biopharmaceutical manufacturing depend on the successful implementation of process analytical technologies that can monitor multiple product quality attributes in a continuous in-line setting. Raman spectroscopy is an emerging technology in the biopharma industry that promises to fit this strategic need, yet its application is not widespread due to limited success for predicting a meaningful number of quality attributes. In this study, we addressed this very problem by demonstrating new capabilities for preprocessing Raman spectra using a series of Butterworth filters. The resulting increase in the number of spectral features is paired with a machine learning algorithm and laboratory automation hardware to drive the automated collection and training of a calibration model that allows for the prediction of 16 different product quality attributes in an in-line mode. The demonstrated ability to generate these Raman-based models for in-process product quality monitoring is the breakthrough to increase process understanding by delivering product quality data in a continuous manner. The implementation of this multiattribute in-line technology will create new workflows within process development, characterization, validation, and control.
Collapse
Affiliation(s)
- Jiarui Wang
- Late Stage Downstream Process Development, Boehringer Ingelheim Pharma GmbH/Co. KG, Biberach an der Riss, Germany
| | - Jingyi Chen
- Late Stage Downstream Process Development, Boehringer Ingelheim Pharma GmbH/Co. KG, Biberach an der Riss, Germany
- Bioprocess development and modelling, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Joey Studts
- Late Stage Downstream Process Development, Boehringer Ingelheim Pharma GmbH/Co. KG, Biberach an der Riss, Germany
| | - Gang Wang
- Late Stage Downstream Process Development, Boehringer Ingelheim Pharma GmbH/Co. KG, Biberach an der Riss, Germany
| |
Collapse
|
6
|
Wu S, Ketcham SA, Corredor C, Both D, Zhao Y, Drennen JK, Anderson CA. Adaptive modeling optimized by the data fusion strategy: Real-time dying cell percentage prediction using capacitance spectroscopy. Biotechnol Prog 2024; 40:e3424. [PMID: 38178645 DOI: 10.1002/btpr.3424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Revised: 11/20/2023] [Accepted: 12/19/2023] [Indexed: 01/06/2024]
Abstract
The previous research showcased a partial least squares (PLS) regression model accurately predicting cell death percentages using in-line capacitance spectra. The current study advances the model accuracy through adaptive modeling employing a data fusion approach. This strategy enhances prediction performance by incorporating variables from the Cole-Cole model, conductivity and its derivatives over time, and Mahalanobis distance into the predictor matrix (X-matrix). Firstly, the Cole-Cole model, a mechanistic model with parameters linked to early cell death onset, was integrated to enhance prediction performance. Secondly, the inclusion of conductivity and its derivatives over time in the X-matrix mitigated prediction fluctuations resulting from abrupt conductivity changes during process operations. Thirdly, Mahalanobis distance, depicting spectral changes relative to a reference spectrum from a previous time point, improved model adaptability to independent test sets, thereby enhancing performance. The final data fusion model substantially decreased root-mean squared error of prediction (RMSEP) by around 50%, which is a significant boost in prediction accuracy compared to the prior PLS model. Robustness against reference spectrum selection was confirmed by consistent performance across various time points. In conclusion, this study illustrates that the data fusion strategy substantially enhances the model accuracy compared to the previous model relying solely on capacitance spectra.
Collapse
Affiliation(s)
- Suyang Wu
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania, USA
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania, USA
| | - Stephanie A Ketcham
- Manufascutring Science and Technology, Bristol-Myers Squibb, Devens, Massachusetts, USA
| | - Claudia Corredor
- Pharmaceutical Development, Bristol-Myers Squibb, New Brunswick, New Jersey, USA
| | - Douglas Both
- Pharmaceutical Development, Bristol-Myers Squibb, New Brunswick, New Jersey, USA
| | - Yuxiang Zhao
- Global Product Development and Supply, Bristol-Myers Squibb, Devens, Massachusetts, USA
| | - James K Drennen
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania, USA
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania, USA
| | - Carl A Anderson
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania, USA
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
7
|
Torres AJ. Robust method for chromatogram shape analysis to improve early detection of performance drifts and adverse changes in process parameters during purification column operations. Biotechnol J 2024; 19:e2300271. [PMID: 38012961 DOI: 10.1002/biot.202300271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 10/13/2023] [Accepted: 11/09/2023] [Indexed: 11/29/2023]
Abstract
The biopharmaceutical industry is under increased pressure to maximize efficiency, enhance quality compliance, and reduce the cost of drug substance manufacturing. Ways to reduce costs associated with manufacturing of complex biological molecules include maximizing efficiency of chromatography purification steps. For example, process analytical technology (PAT) tools can be employed to improve column resin life, prevent column operating failures, and decrease the time it takes to solve investigations of process deviations. We developed a robust method to probe the shape of the chromatogram for indications of column failure or detrimental changes in the process. The approach herein utilizes raw data obtained from manufacturing followed by a pre-processing routine to align chromatograms and patch together the different chromatogram phases in preparation for multivariate analysis. A principal component analysis (PCA) was performed on the standardized chromatograms to compare different batches, and resulted in the identification specific process change that affected the profile. In addition, changes in the chromatogram peaks were used to create predictive models for impurity clearance. This approach has the potential for early detection of column processing issues, improving timely resolution in large-scale chromatographic operations.
Collapse
Affiliation(s)
- Alexis J Torres
- Manufacturing Science and Technology, Pfizer Inc, Sanford, North Carolina, USA
| |
Collapse
|
8
|
Tanemura H, Kitamura R, Yamada Y, Hoshino M, Kakihara H, Nonaka K. Comprehensive modeling of cell culture profile using Raman spectroscopy and machine learning. Sci Rep 2023; 13:21805. [PMID: 38071246 PMCID: PMC10710501 DOI: 10.1038/s41598-023-49257-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 12/06/2023] [Indexed: 12/18/2023] Open
Abstract
Chinese hamster ovary (CHO) cells are widely utilized in the production of antibody drugs. To ensure the production of large quantities of antibodies that meet the required specifications, it is crucial to monitor and control the levels of metabolites comprehensively during CHO cell culture. In recent years, continuous analysis methods employing on-line/in-line techniques using Raman spectroscopy have attracted attention. While these analytical methods can nondestructively monitor culture data, constructing a highly accurate measurement model for numerous components is time-consuming, making it challenging to implement in the rapid research and development of pharmaceutical manufacturing processes. In this study, we developed a comprehensive, simple, and automated method for constructing a Raman model of various components measured by LC-MS and other techniques using machine learning with Python. Preprocessing and spectral-range optimization of data for model construction (partial least square (PLS) regression) were automated and accelerated using Bayes optimization. Subsequently, models were constructed for each component using various model construction techniques, including linear regression, ridge regression, XGBoost, and neural network. This enabled the model accuracy to be improved compared with PLS regression. This automated approach allows continuous monitoring of various parameters for over 100 components, facilitating process optimization and process monitoring of CHO cells.
Collapse
Affiliation(s)
- Hiroki Tanemura
- Biologics Technology Research Laboratories I, Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan.
| | - Ryunosuke Kitamura
- Biologics Technology Research Laboratories I, Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan
| | - Yasuko Yamada
- Analytical & Quality Evaluation Research Laboratories, Pharmaceutical Technology Division, Daiichi Sankyo Co., Ltd., 1-12-1, Shinomiya, Hiratsuka, Kanagawa, 254-0014, Japan
| | - Masato Hoshino
- Biologics Technology Research Laboratories I, Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan
| | - Hirofumi Kakihara
- Biologics Technology Research Laboratories I, Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan
| | - Koichi Nonaka
- Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan
| |
Collapse
|
9
|
Drobnjakovic M, Hart R, Kulvatunyou BS, Ivezic N, Srinivasan V. Current challenges and recent advances on the path towards continuous biomanufacturing. Biotechnol Prog 2023; 39:e3378. [PMID: 37493037 DOI: 10.1002/btpr.3378] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 05/13/2023] [Accepted: 06/21/2023] [Indexed: 07/27/2023]
Abstract
Continuous biopharmaceutical manufacturing is currently a field of intense research due to its potential to make the entire production process more optimal for the modern, ever-evolving biopharmaceutical market. Compared to traditional batch manufacturing, continuous bioprocessing is more efficient, adjustable, and sustainable and has reduced capital costs. However, despite its clear advantages, continuous bioprocessing is yet to be widely adopted in commercial manufacturing. This article provides an overview of the technological roadblocks for extensive adoptions and points out the recent advances that could help overcome them. In total, three key areas for improvement are identified: Quality by Design (QbD) implementation, integration of upstream and downstream technologies, and data and knowledge management. First, the challenges to QbD implementation are explored. Specifically, process control, process analytical technology (PAT), critical process parameter (CPP) identification, and mathematical models for bioprocess control and design are recognized as crucial for successful QbD realizations. Next, the difficulties of end-to-end process integration are examined, with a particular emphasis on downstream processing. Finally, the problem of data and knowledge management and its potential solutions are outlined where ontologies and data standards are pointed out as key drivers of progress.
Collapse
Affiliation(s)
- Milos Drobnjakovic
- Systems Integration Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| | - Roger Hart
- National Institute for Innovation in Manufacturing Biopharmaceuticals, Newark, New Jersey, USA
| | - Boonserm Serm Kulvatunyou
- Systems Integration Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| | - Nenad Ivezic
- Systems Integration Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| | - Vijay Srinivasan
- Systems Integration Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| |
Collapse
|
10
|
Wang J, Chen J, Studts J, Wang G. Automated calibration and in-line measurement of product quality during therapeutic monoclonal antibody purification using Raman spectroscopy. Biotechnol Bioeng 2023; 120:3288-3298. [PMID: 37534801 DOI: 10.1002/bit.28514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 05/12/2023] [Accepted: 07/11/2023] [Indexed: 08/04/2023]
Abstract
Current manufacturing and development processes for therapeutic monoclonal antibodies demand increasing volumes of analytical testing for both real-time process controls and high-throughput process development. The feasibility of using Raman spectroscopy as an in-line product quality measuring tool has been recently demonstrated and promises to relieve this analytical bottleneck. Here, we resolve time-consuming calibration process that requires fractionation and preparative experiments covering variations of product quality attributes (PQAs) by engineering an automation system capable of collecting Raman spectra on the order of hundreds of calibration points from two to three stock seed solutions differing in protein concentration and aggregate level using controlled mixing. We used this automated system to calibrate multi-PQA models that accurately measured product concentration and aggregation every 9.3 s using an in-line flow-cell. We demonstrate the application of a nonlinear calibration model for monitoring product quality in real-time during a biopharmaceutical purification process intended for clinical and commercial manufacturing. These results demonstrate potential feasibility to implement quality monitoring during GGMP manufacturing as well as to increase chemistry, manufacturing, and controls understanding during process development, ultimately leading to more robust and controlled manufacturing processes.
Collapse
Affiliation(s)
- Jiarui Wang
- Late Stage Downstream Process Development, Boehringer Ingelheim Pharma GmbH/Co. KG, Biberach an der Riss, Germany
| | - Jingyi Chen
- Late Stage Downstream Process Development, Boehringer Ingelheim Pharma GmbH/Co. KG, Biberach an der Riss, Germany
- Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Joey Studts
- Late Stage Downstream Process Development, Boehringer Ingelheim Pharma GmbH/Co. KG, Biberach an der Riss, Germany
| | - Gang Wang
- Late Stage Downstream Process Development, Boehringer Ingelheim Pharma GmbH/Co. KG, Biberach an der Riss, Germany
| |
Collapse
|
11
|
Li X. Recent applications of quantitative mass spectrometry in biopharmaceutical process development and manufacturing. J Pharm Biomed Anal 2023; 234:115581. [PMID: 37494866 DOI: 10.1016/j.jpba.2023.115581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/27/2023] [Accepted: 07/12/2023] [Indexed: 07/28/2023]
Abstract
Biopharmaceutical products have seen rapid growth over the past few decades and continue to dominate the global pharmaceutical market. Aligning with the quality by design (QbD) framework and realization, recent advances in liquid chromatography-mass spectrometry (LC-MS) instrumentation and related techniques have enhanced biopharmaceutical characterization capabilities and have supported an increased development of biopharmaceutical products. Beyond its routine qualitative characterization, the quantitative feature of LC-MS has unique applications in biopharmaceutical process development and manufacturing. This review describes the recent applications and implications of the advancement of quantitative MS methods in biopharmaceutical process development, and characterization of biopharmaceutical product, product-related variants, and process-related impurities. We also provide insights on the emerging applications of quantitative MS in the lifecycle of biopharmaceutical product development including quality control in the Good Manufacturing Practice (GMP) environment and process analytical technology (PAT) practices during process development and manufacturing. Through collaboration with instrument and software vendors and regulatory agencies, we envision broader adoption of phase-appropriate quantitative MS-based methods for the analysis of biopharmaceutical products, which in turn has the potential to enable manufacture of higher quality products for patients.
Collapse
Affiliation(s)
- Xuanwen Li
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ 07065, USA.
| |
Collapse
|
12
|
Wu S, Ketcham SA, Corredor CC, Both D, Drennen JK, Anderson CA. Capacitance spectroscopy enables real-time monitoring of early cell death in mammalian cell culture. Biotechnol J 2023; 18:e2200231. [PMID: 36479620 DOI: 10.1002/biot.202200231] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 08/21/2022] [Accepted: 09/06/2022] [Indexed: 12/13/2022]
Abstract
BACKGROUND/AIMS Previous work developed a quantitative model using capacitance spectroscopy in an at-line setup to predict the dying cell percentage measured from a flow cytometer. This work aimed to transfer the at-line model to monitor lab-scale bioreactors in real-time, waiving the need for frequent sampling and enabling precise controls. METHODS AND RESULTS Due to the difference between the at-line and in-line capacitance probes, direct application of the at-line model resulted in poor accuracy and high prediction bias. A new model with a variable range and offering similar spectral shape across all probes was first constructed, improving prediction accuracy. Moreover, the global calibration method included the variance of different probes and scales in the model, reducing prediction bias. External parameter orthogonalization, a preprocessing method, also mitigated the interference from feeding, which further improved model performance. The root-mean-square error of prediction of the final model was 6.56% (8.42% of the prediction range) with an R2 of 92.4%. CONCLUSION The culture evolution trajectory predicted by the in-line model captured the cell death and alarmed cell death onset earlier than the trypan blue exclusion test. Additionally, the incorporation of at-line spectra following orthogonal design into the calibration set was shown to generate calibration models that are more robust than the calibration models constructed using the in-line spectra only. This is advantageous, as at-line spectral collection is easier, faster, and more material-sparing than in-line spectra collection.
Collapse
Affiliation(s)
- Suyang Wu
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania, USA.,Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania, USA
| | - Stephanie A Ketcham
- Manufacturing Science and Technology, Bristol-Myers Squibb, Devens, Massachusetts, USA
| | - Claudia C Corredor
- Pharmaceutical Development, Bristol-Myers Squibb, New Brunswick, New Jersey, USA
| | - Douglas Both
- Pharmaceutical Development, Bristol-Myers Squibb, New Brunswick, New Jersey, USA
| | - James K Drennen
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania, USA.,Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania, USA
| | - Carl A Anderson
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania, USA.,Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
13
|
Milewska A, Baekelandt G, Boutaieb S, Mozin V, Falconbridge A. In-line monitoring of protein concentration with MIR spectroscopy during UFDF. Eng Life Sci 2022; 23:e2200050. [PMID: 36751473 PMCID: PMC9893749 DOI: 10.1002/elsc.202200050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 11/22/2022] [Accepted: 12/13/2022] [Indexed: 12/25/2022] Open
Abstract
Rapid increase of product titers in upstream processes has presented challenges for downstream processing, where purification costs increase linearly with the increase of the product yield. Hence, innovative solutions are becoming increasingly popular. Process Analytical Technology (PAT) tools, such as spectroscopic techniques, are on the rise due to their capacity to provide real-time, precise analytics. This ensures consistent product quality and increased process understanding, as well as process control. Mid-infrared spectroscopy (MIR) has emerged as a highly promising technique within recent years, owing to its ability to monitor several critical process parameters at the same time and unchallenging spectral analysis and data interpretation. For in-line monitoring, Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy (ATR-FTIR) is a method of choice, as it enables reliable measurements in a liquid environment, even though water absorption bands are present in the region of interest. Here, we present MIR spectroscopy as a monitoring tool of critical process parameters in ultrafiltration/diafiltration (UFDF). MIR spectrometer was integrated in the UFDF process in an in-line fashion through a single-use flow cell containing a single bounce silicon ATR crystal. The results indicate that the one-point calibration algorithm applied to the MIR spectra, predicts highly accurate protein concentrations, as compared with validated offline analytical methods.
Collapse
|
14
|
Matte A. Recent Advances and Future Directions in Downstream Processing of Therapeutic Antibodies. Int J Mol Sci 2022; 23:ijms23158663. [PMID: 35955796 PMCID: PMC9369434 DOI: 10.3390/ijms23158663] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 08/01/2022] [Accepted: 08/02/2022] [Indexed: 02/05/2023] Open
Abstract
Despite the advent of many new therapies, therapeutic monoclonal antibodies remain a prominent biologics product, with a market value of billions of dollars annually. A variety of downstream processing technological advances have led to a paradigm shift in how therapeutic antibodies are developed and manufactured. A key driver of change has been the increased adoption of single-use technologies for process development and manufacturing. An early-stage developability assessment of potential lead antibodies, using both in silico and high-throughput experimental approaches, is critical to de-risk development and identify molecules amenable to manufacturing. Both statistical and mechanistic modelling approaches are being increasingly applied to downstream process development, allowing for deeper process understanding of chromatographic unit operations. Given the greater adoption of perfusion processes for antibody production, continuous and semi-continuous downstream processes are being increasingly explored as alternatives to batch processes. As part of the Quality by Design (QbD) paradigm, ever more sophisticated process analytical technologies play a key role in understanding antibody product quality in real-time. We should expect that computational prediction and modelling approaches will continue to be advanced and exploited, given the increasing sophistication and robustness of predictive methods compared to the costs, time, and resources required for experimental studies.
Collapse
Affiliation(s)
- Allan Matte
- Downstream Processing Team, Bioprocess Engineering Department, Human Health Therapeutics Research Center, National Research Council Canada, 6100 Royalmount Avenue, Montreal, QC H4P 2R2, Canada
| |
Collapse
|
15
|
Chen R, Chen XJ, Shi C, Jiao B, Shi Y, Yao B, Lin DQ, Gong W, Hsu S. Converting a mAb downstream process from batch to continuous using process modeling and process analytical technology. Biotechnol J 2022; 17:e2100351. [PMID: 35908168 DOI: 10.1002/biot.202100351] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 07/28/2022] [Accepted: 07/28/2022] [Indexed: 11/06/2022]
Abstract
The biopharmaceutical market is driving the revolution from traditional batch processes to continuous manufacturing for higher productivity and lower costs. In this work, a batch mAb downstream process has been converted into an integrated continuous process with the combination of multiple techniques. For process intensification, two batch mode unit operations (protein A capture chromatography, ultrafiltration/diafiltration) are converted into continuous ones; For continuity, surge tanks were used between adjacent steps, and level signals were used to trigger process start or stop, forming a holistic continuous process. For process automation, manual operations (e.g., pH and conductivity adjustment) were changed into automatic operation and load mass was controlled with process analytical technology (PAT). A model-based simulation was applied to estimate the loading conditions for the continuous capture process, resulting in 21% resin capacity utilization and 28% productivity improvement as compared to the batch process. Automatic load mass control of cation exchange chromatography was achieved through a customized in-line protein quantity monitoring system, with a difference of less than 1.3% as compared to off-line analysis. Total process time was shortened from 4 days (batch process) to less than 24 hours using the continuous downstream process with the overall productivity of 23.8 g mAb /day for the bench-scale system. Comparable yield and quality data were obtained in three test runs, indicating a successful conversion from a batch process to a continuous process. The insight of this work could be a reference to other similar situations. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Ran Chen
- Shanghai Engineering Research Center of Anti-tumor Biological Drugs, Shanghai Henlius Biotech, Inc., Shanghai, China
| | - Xu-Jun Chen
- Shanghai Engineering Research Center of Anti-tumor Biological Drugs, Shanghai Henlius Biotech, Inc., Shanghai, China
| | - Ce Shi
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, China
| | - Biao Jiao
- Shanghai Engineering Research Center of Anti-tumor Biological Drugs, Shanghai Henlius Biotech, Inc., Shanghai, China
| | - Ye Shi
- Shanghai Engineering Research Center of Anti-tumor Biological Drugs, Shanghai Henlius Biotech, Inc., Shanghai, China
| | - Bin Yao
- Shanghai Engineering Research Center of Anti-tumor Biological Drugs, Shanghai Henlius Biotech, Inc., Shanghai, China
| | - Dong-Qiang Lin
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, China
| | - Wei Gong
- Shanghai Engineering Research Center of Anti-tumor Biological Drugs, Shanghai Henlius Biotech, Inc., Shanghai, China
| | - Simon Hsu
- Shanghai Engineering Research Center of Anti-tumor Biological Drugs, Shanghai Henlius Biotech, Inc., Shanghai, China
| |
Collapse
|
16
|
Graf A, Lemke J, Schulze M, Soeldner R, Rebner K, Hoehse M, Matuszczyk J. A Novel Approach for Non-Invasive Continuous In-Line Control of Perfusion Cell Cultivations by Raman Spectroscopy. Front Bioeng Biotechnol 2022; 10:719614. [PMID: 35547168 PMCID: PMC9081366 DOI: 10.3389/fbioe.2022.719614] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 04/04/2022] [Indexed: 11/13/2022] Open
Abstract
Continuous manufacturing is becoming more important in the biopharmaceutical industry. This processing strategy is favorable, as it is more efficient, flexible, and has the potential to produce higher and more consistent product quality. At the same time, it faces some challenges, especially in cell culture. As a steady state has to be maintained over a prolonged time, it is unavoidable to implement advanced process analytical technologies to control the relevant process parameters in a fast and precise manner. One such analytical technology is Raman spectroscopy, which has proven its advantages for process monitoring and control mostly in (fed-) batch cultivations. In this study, an in-line flow cell for Raman spectroscopy is included in the cell-free harvest stream of a perfusion process. Quantitative models for glucose and lactate were generated based on five cultivations originating from varying bioreactor scales. After successfully validating the glucose model (Root Mean Square Error of Prediction (RMSEP) of ∼0.2 g/L), it was employed for control of an external glucose feed in cultivation with a glucose-free perfusion medium. The generated model was successfully applied to perform process control at 4 g/L and 1.5 g/L glucose over several days, respectively, with variability of ±0.4 g/L. The results demonstrate the high potential of Raman spectroscopy for advanced process monitoring and control of a perfusion process with a bioreactor and scale-independent measurement method.
Collapse
Affiliation(s)
- A. Graf
- Product Development, Sartorius Stedim Biotech GmbH, Göttingen, Germany
| | - J. Lemke
- Corporate Research, Sartorius Stedim Biotech GmbH, Göttingen, Germany
- *Correspondence: J. Lemke,
| | - M. Schulze
- Corporate Research, Sartorius Stedim Biotech GmbH, Göttingen, Germany
| | - R. Soeldner
- Corporate Research, Sartorius Stedim Biotech GmbH, Göttingen, Germany
| | - K. Rebner
- Process Analysis and Technology PA&T, Reutlingen University, Reutlingen, Germany
| | - M. Hoehse
- Product Development, Sartorius Stedim Biotech GmbH, Göttingen, Germany
| | - J. Matuszczyk
- Corporate Research, Sartorius Stedim Biotech GmbH, Göttingen, Germany
| |
Collapse
|