1
|
Bedair A, Hamed M, Mansour FR. Reshaping Capillary Electrophoresis With State-of-the-Art Sample Preparation Materials: Exploring New Horizons. Electrophoresis 2024. [PMID: 39345230 DOI: 10.1002/elps.202400114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Revised: 08/12/2024] [Accepted: 09/02/2024] [Indexed: 10/01/2024]
Abstract
Capillary electrophoresis (CE) is a powerful analysis technique with advantages such as high separation efficiency with resolution factors above 1.5, low sample consumption of less than 10 µL, cost-effectiveness, and eco-friendliness such as reduced solvent use and lower operational costs. However, CE also faces limitations, including limited detection sensitivity for low-concentration samples and interference from complex biological matrices. Prior to performing CE, it is common to utilize sample preparation procedures such as solid-phase microextraction (SPME) and liquid-phase microextraction (LPME) in order to improve the sensitivity and selectivity of the analysis. Recently, there have been advancements in the development of novel materials that have the potential to greatly enhance the performance of SPME and LPME. This review examines various materials and their uses in microextraction when combined with CE. These materials include carbon nanotubes, covalent organic frameworks, metal-organic frameworks, graphene and its derivatives, molecularly imprinted polymers, layered double hydroxides, ionic liquids, and deep eutectic solvents. The utilization of these innovative materials in extraction methods is being examined. Analyte recoveries and detection limits attained for a range of sample matrices are used to assess their effects on extraction selectivity, sensitivity, and efficiency. Exploring new materials for use in sample preparation techniques is important as it enables researchers to address current limitations of CE. The development of novel materials has the potential to greatly enhance extraction selectivity, sensitivity, and efficiency, thereby improving CE performance for complex biological analysis.
Collapse
Affiliation(s)
- Alaa Bedair
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, Egypt
| | - Mahmoud Hamed
- Pharmaceutical Chemistry Department, Faculty of Pharmacy, Misr International University, Cairo, Egypt
| | - Fotouh R Mansour
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| |
Collapse
|
2
|
Chen Q, Lu Q, Zhang L, Zhang C, Zhang J, Gu Y, Huang Q, Tang H. A novel endogenous retention-index for minimizing retention-time variations in metabolomic analysis with reversed-phase ultrahigh-performance liquid-chromatography and mass spectrometry. Talanta 2024; 268:125318. [PMID: 37875029 DOI: 10.1016/j.talanta.2023.125318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 10/07/2023] [Accepted: 10/14/2023] [Indexed: 10/26/2023]
Abstract
Consistent retention time (tR) of metabolites is vital for identification in metabolomic analysis with ultrahigh-performance liquid-chromatography (UPLC). To minimize inter-experimental tR variations from the reversed-phase UPLC-MS, we developed an endogenous retention-index (endoRI) using in-sample straight-chain acylcarnitines with different chain-length (LC, C0-C26) without additives. The endoRI-corrections reduced the tR variations caused by the combined changes of mobile phases, gradients, flow-rates, elution time, columns and temperature from up to 5.1 min-0.2 min for most metabolites in a model metabolome consisting of 91 metabolites and multiple biological matrices including human serum, plasma, fecal, urine, A549 cells and rabbit liver extracts. The endoRI-corrections also reduced the inter-batch and inter-platform tR variations from 1.5 min to 0.15 min for 95 % of detected features in the above biological samples. We further established a quantitative model between tR and LC for predicting tR values of acylcarnitines when absent in samples. This makes it possible to compare metabolites' tR from different tR databases and the UPLC-based metabolomic data from different batches.
Collapse
Affiliation(s)
- Qinsheng Chen
- State Key Laboratory of Genetic Engineering, School of Life Sciences, Human Phenome Institute, Zhangjiang Fudan International Innovation Center, Metabonomics and Systems Biology Laboratory at Shanghai International Centre for Molecular Phenomics, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Qinwei Lu
- State Key Laboratory of Genetic Engineering, School of Life Sciences, Human Phenome Institute, Zhangjiang Fudan International Innovation Center, Metabonomics and Systems Biology Laboratory at Shanghai International Centre for Molecular Phenomics, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Lianglong Zhang
- State Key Laboratory of Genetic Engineering, School of Life Sciences, Human Phenome Institute, Zhangjiang Fudan International Innovation Center, Metabonomics and Systems Biology Laboratory at Shanghai International Centre for Molecular Phenomics, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Chenhan Zhang
- State Key Laboratory of Genetic Engineering, School of Life Sciences, Human Phenome Institute, Zhangjiang Fudan International Innovation Center, Metabonomics and Systems Biology Laboratory at Shanghai International Centre for Molecular Phenomics, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Jingxian Zhang
- State Key Laboratory of Genetic Engineering, School of Life Sciences, Human Phenome Institute, Zhangjiang Fudan International Innovation Center, Metabonomics and Systems Biology Laboratory at Shanghai International Centre for Molecular Phenomics, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Yu Gu
- State Key Laboratory of Genetic Engineering, School of Life Sciences, Human Phenome Institute, Zhangjiang Fudan International Innovation Center, Metabonomics and Systems Biology Laboratory at Shanghai International Centre for Molecular Phenomics, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Qingxia Huang
- State Key Laboratory of Genetic Engineering, School of Life Sciences, Human Phenome Institute, Zhangjiang Fudan International Innovation Center, Metabonomics and Systems Biology Laboratory at Shanghai International Centre for Molecular Phenomics, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
| | - Huiru Tang
- State Key Laboratory of Genetic Engineering, School of Life Sciences, Human Phenome Institute, Zhangjiang Fudan International Innovation Center, Metabonomics and Systems Biology Laboratory at Shanghai International Centre for Molecular Phenomics, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
| |
Collapse
|
3
|
Jiang RW, Jaroch K, Pawliszyn J. Solid-phase microextraction of endogenous metabolites from intact tissue validated using a Biocrates standard reference method kit. J Pharm Anal 2023; 13:55-62. [PMID: 36816540 PMCID: PMC9937786 DOI: 10.1016/j.jpha.2022.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 09/22/2022] [Accepted: 09/22/2022] [Indexed: 11/06/2022] Open
Abstract
Improved analytical methods for the metabolomic profiling of tissue samples are constantly needed. Currently, conventional sample preparation methods often involve tissue biopsy and/or homogenization, which disrupts the endogenous metabolome. In this study, solid-phase microextraction (SPME) fibers were used to monitor changes in endogenous compounds in homogenized and intact ovine lung tissue. Following SPME, a Biocrates AbsoluteIDQ assay was applied to make a downstream targeted metabolomics analysis and confirm the advantages of in vivo SPME metabolomics. The AbsoluteIDQ kit enabled the targeted analysis of over 100 metabolites via solid-liquid extraction and SPME. Statistical analysis revealed significant differences between conventional liquid extractions from homogenized tissue and SPME results for both homogenized and intact tissue samples. In addition, principal component analysis revealed separated clustering among all the three sample groups, indicating changes in the metabolome due to tissue homogenization and the chosen sample preparation method. Furthermore, clear differences in free metabolites were observed when extractions were performed on the intact and homogenized tissue using identical SPME procedures. Specifically, a direct comparison showed that 47 statistically distinct metabolites were detected between the homogenized and intact lung tissue samples (P < 0.05) using mixed-mode SPME fibers. These changes were probably due to the disruptive homogenization of the tissue. This study's findings highlight both the importance of sample preparation in tissue-based metabolomics studies and SPME's unique ability to perform minimally invasive extractions without tissue biopsy or homogenization while providing broad metabolite coverage.
Collapse
Affiliation(s)
- Runshan Will Jiang
- Department of Chemistry, University of Waterloo, Waterloo, N2L 3G1, Canada
| | - Karol Jaroch
- Department of Chemistry, University of Waterloo, Waterloo, N2L 3G1, Canada,Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, Bydgoszcz, 85-089, Poland
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, N2L 3G1, Canada,Corresponding author.
| |
Collapse
|
4
|
Sumina EG, Shtykov SN, Reshetnikova IS, Yurasov NA, Uglanova VZ. Micellar Thin-Layer Chromatography and Preconcentration of L-Carnitine with Magnetite Nanoparticles. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822080160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
5
|
El-Malla SF, Elattar RH, Kamal AH, Mansour FR. A highly sensitive switch-on spectrofluorometric method for determination of ascorbic acid using a selective eco-friendly approach. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 270:120802. [PMID: 34973618 PMCID: PMC9759832 DOI: 10.1016/j.saa.2021.120802] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2021] [Revised: 12/18/2021] [Accepted: 12/21/2021] [Indexed: 06/14/2023]
Abstract
Ascorbic acid has recently been extensively used due to its role in the management of COVID-19 infections by stimulating the immune system and triggering phagocytosis of the corona virus. The currently used spectrofluorometric methods for determination of ascorbic acid require using derivatizing agents or fluorescent probes and suffer from a number of limitations, including slow reaction rates, low yield, limited sensitivity, long reaction times and high temperatures. In this work, we present a highly sensitive spectrofluorometric method for determination of ascorbic acid by switching-on the fluorescence of salicylate in presence of iron (III) due to a reduction of the cation to iron (II). The addition of ascorbic acid resulted in a corresponding enhancement in the fluorescence intensity of iron (III)-salicylate complex at emission wavelength = 411 nm. The method was found linear in the range of 1-8 µg/mL with a correlation coefficient of 0.9997. The limits of detection and quantitation were 0.035 µg/mL and 0.106 µg/mL, respectively. The developed method was applied for the determination of ascorbic acid in the commercially available dosage form; Ruta C60® tablets. The obtained results were compared with those obtained by a reported liquid chromatographic method at 95% confidence interval, no statistically significant differences were found between the developed and the reported methods. Yet, the developed spectrofluorometric method was found markedly greener than the reference method, based on the analytical Eco-scale and the green analytical procedure index. This work presents a simple, rapid and sensitive method that can possibly be applied for determination of ascorbic acid in pharmaceuticals, biological fluids and food samples.
Collapse
Affiliation(s)
- Samah F El-Malla
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt.
| | - Rehab H Elattar
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt.
| | - Amira H Kamal
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt.
| | - Fotouh R Mansour
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt; Pharmaceutical Services Center, Faculty of Pharmacy, Tanta University, Tanta 3111, Egypt.
| |
Collapse
|
6
|
Luna C, Griffin C, Miller MJ. A clinically validated method to separate and quantify underivatized acylcarnitines and carnitine metabolic intermediates using mixed-mode chromatography with tandem mass spectrometry. J Chromatogr A 2021; 1663:462749. [PMID: 34954532 DOI: 10.1016/j.chroma.2021.462749] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 12/10/2021] [Accepted: 12/12/2021] [Indexed: 10/19/2022]
Abstract
Acylcarnitines are intermediate metabolites of the mitochondria that serve as biomarkers for inherited disorders of fatty acid oxidation and amino acid metabolism. The prevailing clinical method used to quantify acylcarnitines involves flow-injection tandem mass spectrometry, an approach with a number of limitations; foremost the inability to separate and therefore distinguish key isobaric acylcarnitine species. To address these issues, we report a clinically validated liquid chromatography tandem mass spectrometry method to quantify acylcarnitines, free carnitine, and carnitine metabolic intermediates in human plasma. Importantly, this method resolves clinically relevant isobaric and isomeric acylcarnitine species in a single 22 min analysis without the use of ion pairing or derivatization reagents. This unique combination of features is not achievable by existing acylcarnitine methods and is made possible by the use of a novel mixed-mode chromatographic separation. Further clinical validation studies demonstrate excellent limits of quantification, linearity, accuracy, and inter-assay precision for analyses of 38 different calibrated analytes. An additional 28 analytes are semi-quantitatively analyzed using surrogate calibrators. The study of residual patient specimens confirms the clinical utility of this method and suggests expanded applicability to the diagnosis of peroxisomal disorders. In summary, we report a clinically validated acylcarnitine method that utilizes a novel mixed-mode chromatographic separation to provide a number of advantages in terms of specificity, accuracy, sample preparation time, and clinical utility.
Collapse
Affiliation(s)
- Carolina Luna
- Department of Medical and Molecular Genetics, Indiana University School of Medicine, 975 W. Walnut St., IB-344C, Indianapolis, IN 46202, United States
| | - Chandler Griffin
- Department of Medical and Molecular Genetics, Indiana University School of Medicine, 975 W. Walnut St., IB-344C, Indianapolis, IN 46202, United States
| | - Marcus J Miller
- Department of Medical and Molecular Genetics, Indiana University School of Medicine, 975 W. Walnut St., IB-344C, Indianapolis, IN 46202, United States.
| |
Collapse
|
7
|
Villaseñor A, Godzien J, Barker-Tejeda TC, Gonzalez-Riano C, López-López Á, Dudzik D, Gradillas A, Barbas C. Analytical approaches for studying oxygenated lipids in the search of potential biomarkers by LC-MS. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116367] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
8
|
Hammad SF, Abdallah IA, Bedair A, Mansour FR. Homogeneous liquid-liquid extraction as an alternative sample preparation technique for biomedical analysis. J Sep Sci 2021; 45:185-209. [PMID: 34472701 DOI: 10.1002/jssc.202100452] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 08/26/2021] [Accepted: 08/27/2021] [Indexed: 12/12/2022]
Abstract
Liquid-liquid extraction is a widely used technique of sample preparation in biomedical analysis. In spite of the high pre-concentration capacities of liquid-liquid extraction, it suffers from a number of limitations including time and effort consumption, large organic solvent utilization, and poor performance in highly polar analytes. Homogeneous liquid-liquid extraction is an alternative sample preparation technique that overcomes some drawbacks of conventional liquid-liquid extraction, and allows employing greener organic solvents in sample treatment. In homogeneous liquid-liquid extraction, a homogeneous phase is formed between the aqueous sample and the water-miscible extractant, followed by chemically or physically induced phase separation. To form the homogeneous phase, aqueous samples are mixed with water-miscible organic solvents, water-immiscible solvents/cosolvents, surfactants, or smart polymers. Then, phase separation is induced chemically (adding salt, sugar, or buffer) or physically (changing temperature or pH). This mode is rapid, sustainable, and cost-effective in comparison with other sample preparation techniques. Moreover, homogeneous liquid-liquid extraction is more suitable for the extraction of delicate macromolecules such as enzymes, hormones, and proteins and it is more compatible with liquid chromatography with tandem mass spectrometry, which is a vital technique in metabolomics and proteomics. In this review, the principle, types, applications, automation, and technical aspects of homogeneous liquid-liquid extraction are discussed.
Collapse
Affiliation(s)
- Sherin F Hammad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| | - Inas A Abdallah
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, Egypt
| | - Alaa Bedair
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, Egypt
| | - Fotouh R Mansour
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt.,Pharmaceutical Services Center, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| |
Collapse
|
9
|
Esmati P, Najjar N, Emamgholipour S, Hosseinkhani S, Arjmand B, Soleimani A, Kakaii A, Razi F. Mass spectrometry with derivatization method for concurrent measurement of amino acids and acylcarnitines in plasma of diabetic type 2 patients with diabetic nephropathy. J Diabetes Metab Disord 2021; 20:591-599. [PMID: 34222079 PMCID: PMC8212236 DOI: 10.1007/s40200-021-00786-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Accepted: 03/20/2021] [Indexed: 10/24/2022]
Abstract
BACKGROUND Amino acids (AAs) and acylcarnitines play a key role in metabolic disease and can be used as biomarkers of various diseases such as malignancies, type 2 diabetes (T2D), insulin resistance, and cardiovascular diseases, therefore, designing an accurate and simple laboratory method that simultaneously measure both groups of substances, could improve the process of analytes quantification. In this research, a flow injection tandem mass spectrometry (FI-MS/MS) method for simultaneous measurement of AAs and acylcarnitines in addition to results of validation is explained. METHODS Samples were mixed with internal standards and after derivatization (with butanolic-HCL), AAs, and acylcarnitines were quantified by tandem mass spectrometry (SCIEX API 3200). Analytical performance studies were designed based on the Clinical and Laboratory Standards Institute (CLSI) guidelines including precision, accuracy, linearity, and limit of detection-quantification (LOD-LOQ) experiments. Samples from patients with T2D in different stages of kidney disease were also analyzed to ensure the clinical usage of the method. RESULTS Performance evaluation of the method demonstrated adequate results. The mean of estimated inter-assay precision (reported as a coefficient variation) for AAs and acylcarnitines were less than 8.7% and 12.3%, the estimated mean bias was below 8.8% and 10.2% respectively. LOD of analytes ranged between 0.6-10 μmol per liter (μmol/L) for AAs and 0.02-1 μmol/L for acylcarnitines. LOQ analytes showed a range of 2-25 μmol/L and 0.05-5 μmol/L for AAs and carnitine/acylcarnitines respectively. In diabetic patients sample analysis, a significant increase in acylcarnitines (C2, C4, C5DC, C6, C8, C10, C14) and citrulline with a significant decrease in valine were seen in patients with severely increased albuminuria. CONCLUSION FI-MS/MS method with pre-injection derivatization with butanolic-HCL can be used for concurrent measurement of AAs and carnitine/acylcarnitines in a short time and it satisfies the analytical performance requirements. This method is applied for AAs and carnitine/acylcarnitines measurement in patient with T2DM and results show some of the acylcarnitines and AAs can be involved in diabetic nephropathy development. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s40200-021-00786-3.
Collapse
Affiliation(s)
- Parsa Esmati
- Department of mechanical engineering, University of Bristol, Bristol, UK
- Metabolomics and genomics research center, Endocrinology and metabolism molecular-cellular sciences institute, Tehran University of medical sciences, Tehran, Iran
| | - Niloufar Najjar
- Metabolomics and genomics research center, Endocrinology and metabolism molecular-cellular sciences institute, Tehran University of medical sciences, Tehran, Iran
| | - Solaleh Emamgholipour
- Department of Clinical Biochemistry, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Shaghayegh Hosseinkhani
- Department of Clinical Biochemistry, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Babak Arjmand
- Metabolomics and genomics research center, Endocrinology and metabolism molecular-cellular sciences institute, Tehran University of medical sciences, Tehran, Iran
- Cell Therapy and Regenerative Medicine Research Center, Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Amin Soleimani
- Metabolic Disorders Research Center, Endocrinology and Metabolism Molecular -Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Ardeshir Kakaii
- Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Farideh Razi
- Diabetes Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Beneath Dr. Shariati Hospital, Gomnam Highway, Tehran, Iran
| |
Collapse
|
10
|
Salting-out induced liquid-liquid microextraction for alogliptin benzoate determination in human plasma by HPLC/UV. BMC Chem 2021; 15:2. [PMID: 33451337 PMCID: PMC7809805 DOI: 10.1186/s13065-020-00729-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 12/10/2020] [Indexed: 01/22/2023] Open
Abstract
Salting-out induced liquid–liquid microextraction method has been developed for plasma sample treatment before determination of alogliptin by high performance liquid chromatography with UV detection. Several parameters were optimized to achieve maximum enrichment, including type of extractant, volume of extractant, type of anion, type of cation, salt amount and pH. The optimum conditions were attained using 500 µL of acetonitrile, added to 1 mL of aqueous sample containing 250 mg of sodium chloride at pH 12. An RP-HPLC method was developed and validated according to the International Conference on Harmonization guidelines M10. The method was linear in the concentration range of 0.1 to 50 µg/mL (correlation coefficient = 0.997). The limit of detection was 0.019 µg/mL and limit of quantitation was 0.06 µg/mL. The method was accurate and precise with an average % recovery of 99.7% and a % relative standard deviation ranging between 1.5 and 2.5. These results showed that the salting-out induced liquid–liquid microextraction methods could be better than other sample preparation protocols in terms of sensitivity, easiness, solvent consumption and waste reduction.
Collapse
|
11
|
Fromenty B. Inhibition of mitochondrial fatty acid oxidation in drug-induced hepatic steatosis. LIVER RESEARCH 2019. [DOI: 10.1016/j.livres.2019.06.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
12
|
Li S, Gao D, Jiang Y. Function, Detection and Alteration of Acylcarnitine Metabolism in Hepatocellular Carcinoma. Metabolites 2019; 9:E36. [PMID: 30795537 PMCID: PMC6410233 DOI: 10.3390/metabo9020036] [Citation(s) in RCA: 87] [Impact Index Per Article: 17.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 02/07/2019] [Accepted: 02/14/2019] [Indexed: 01/01/2023] Open
Abstract
Acylcarnitines play an essential role in regulating the balance of intracellular sugar and lipid metabolism. They serve as carriers to transport activated long-chain fatty acids into mitochondria for β-oxidation as a major source of energy for cell activities. The liver is the most important organ for endogenous carnitine synthesis and metabolism. Hepatocellular carcinoma (HCC), a primary malignancy of the live with poor prognosis, may strongly influence the level of acylcarnitines. In this paper, the function, detection and alteration of acylcarnitine metabolism in HCC were briefly reviewed. An overview was provided to introduce the metabolic roles of acylcarnitines involved in fatty acid β-oxidation. Then different analytical platforms and methodologies were also briefly summarised. The relationship between HCC and acylcarnitine metabolism was described. Many of the studies reported that short, medium and long-chain acylcarnitines were altered in HCC patients. These findings presented current evidence in support of acylcarnitines as new candidate biomarkers for studies on the pathogenesis and development of HCC. Finally we discussed the challenges and perspectives of exploiting acylcarnitine metabolism and its related metabolic pathways as a target for HCC diagnosis and prognosis.
Collapse
Affiliation(s)
- Shangfu Li
- State Key Laboratory of Chemical Oncogenomics, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
- National & Local United Engineering Lab for Personalized Anti-tumour Drugs, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| | - Dan Gao
- State Key Laboratory of Chemical Oncogenomics, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
- National & Local United Engineering Lab for Personalized Anti-tumour Drugs, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
- Key Laboratory of Metabolomics at Shenzhen, Shenzhen 518055, China.
| | - Yuyang Jiang
- State Key Laboratory of Chemical Oncogenomics, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
- School of Pharmaceutical Sciences, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
13
|
Andrianova MS, Kuznetsov EV, Grudtsov VP, Kuznetsov AE. CMOS-compatible biosensor for L-carnitine detection. Biosens Bioelectron 2018; 119:48-54. [PMID: 30098466 DOI: 10.1016/j.bios.2018.07.044] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 07/11/2018] [Accepted: 07/22/2018] [Indexed: 02/07/2023]
Abstract
A CMOS-compatible ISFET with a Ta2O5 sensitive surface was developed. The structure was optimized for achieving high sensitivity using a subthreshold operation mode and by reducing the influence of the capacitances on the value of subthreshold swing. The developed ISFET was used as a basis for a biosensor for L-carnitine detection. To this end, carnitine acetyltransferase was immobilized on the ISFET sensitive surface. The immobilized enzyme was active (0.082 U/g model plate). The complete microsystem, consisting of a packaged chip, an immobilized enzyme and a microfluidic channel, detected L-carnitine at a range of 0.2-100 μM with a LOD of 0.2 μM. The biosensor response was linear in the range of 0.2-50 μM of L-carnitine with sensitivity 18.0 ± 1.7 mV/μM. An experiment with artificial urine containing 1.3 μM L-carnitine showed that the proposed biosensor could be used on a real sample. Therefore, a new sensor specially optimized for biosensing CMOS-compatible ISFET structures and direct determination of L-carnitine with immobilized carnitine acetyltransferase was developed.
Collapse
Affiliation(s)
- M S Andrianova
- Scientific-Manufacturing Complex Technological Centre, 124498, Shokina square, h. 1, bld. 7, Zelenograd, Moscow, Russia.
| | - E V Kuznetsov
- Scientific-Manufacturing Complex Technological Centre, 124498, Shokina square, h. 1, bld. 7, Zelenograd, Moscow, Russia
| | - V P Grudtsov
- Scientific-Manufacturing Complex Technological Centre, 124498, Shokina square, h. 1, bld. 7, Zelenograd, Moscow, Russia
| | - A E Kuznetsov
- Scientific-Manufacturing Complex Technological Centre, 124498, Shokina square, h. 1, bld. 7, Zelenograd, Moscow, Russia
| |
Collapse
|
14
|
Mansour FR, Khairy MA. Pharmaceutical and biomedical applications of dispersive liquid–liquid microextraction. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1061-1062:382-391. [DOI: 10.1016/j.jchromb.2017.07.055] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2017] [Revised: 07/09/2017] [Accepted: 07/29/2017] [Indexed: 01/18/2023]
|
15
|
Serum lipid alterations identified in chronic hepatitis B, hepatitis B virus-associated cirrhosis and carcinoma patients. Sci Rep 2017; 7:42710. [PMID: 28198443 PMCID: PMC5309878 DOI: 10.1038/srep42710] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Accepted: 01/12/2017] [Indexed: 01/03/2023] Open
Abstract
The incidences of chronic hepatitis B (CHB), Hepatitis B virus (HBV)-associated cirrhosis and HBV-associated carcinoma are high and increasing. This study was designed to evaluate serum lipid metabolite changes that are associated with the progression from CHB to HBV-associated cirrhosis and ultimately to HBV-associated HCC. A targeted metabolomic assay was performed in fasting sera from 136 CHB patients, 104 HBV-associated cirrhosis, and 95 HBV-associated HCC using ultra-performance liquid chromatography triple quadrupole mass spectrometry. A total of 140 metabolites were identified. Clear separations between each two groups were obtained using the partial least squares discriminate analysis of 9 lipid metabolites. Progressively lower levels of long-chain lysophosphatidylcholines (lysoPC a C18:2, lysoPC a C20:3, lysoPC a C20:4) were observed from CHB to cirrhosis to carcinoma; lower levels of lysoPC a C20:4 were found in patients with higher model for end-stage liver disease in the same disease group; and lysoPC a C20:3 levels were lower in Child-Pugh Class C than in Class A and Class B in HBV-associated cirrhosis and HBV-associated HCC groups. The octadecadienyl carnitine level was higher in HBV-associated cirrhosis group than in other two groups. Serum levels of selected long-chain lysoPCs are promising markers for the progression of HBV-associated liver diseases.
Collapse
|
16
|
Olkhovych O, Volkogon M, Taran N, Batsmanova L, Kravchenko I. The Effect of Copper And Zinc Nanoparticles on the Growth Parameters, Contents of Ascorbic Acid, and Qualitative Composition of Amino Acids and Acylcarnitines in Pistia stratiotes L. (Araceae). NANOSCALE RESEARCH LETTERS 2016; 11:218. [PMID: 27107771 PMCID: PMC4842196 DOI: 10.1186/s11671-016-1422-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Accepted: 04/13/2016] [Indexed: 05/18/2023]
Abstract
The paper covers the research of copper and zinc nanoparticle effect on the content of ascorbic acid, and quantitative and qualitative composition of amino acids and acylcarnitines in Pistia stratiotes L. plants. Plant exposition to copper nanoparticles led to the decrease in (1) the amount of ascorbic acid, (2) the total content of amino acids (by 25 %), and (3) the amount of all studied amino acids except for the glycine amino acid. At this, the amount of 5-oxoproline, arginine, leucine, ornithine, phenylalanine, proline, serine, and tyrosine was two times lower than in control plants. The reduction of the contents of 8 out of 12 investigated acylcarnitines (namely C0, C2, C3, C5, C6, C8, C16, C18:1) was observed in plants under the influence of copper nanoparticles. The result of plants incubation with zinc nanoparticles was the decrease in (1) the amount of ascorbic acid, (2) the total content of amino acids (by 15 %), (3) the content of leucine, methionine, phenylalanine, proline, and tyrosine (more than twice), and (4) the content of 10 acylcarnitines (C0, C2, C3, C4, C5, C10, C16, C18, C18:1, C18:2). The observed reduction in amino acid contents may negatively affect plants adaptive reactions associated with de novo synthesis of stress proteins. At the same time, the decrease in the content of acylcarnitines, responsible for fatty acid transportation, may lead to the changes in the activity and direction of lipid metabolism in plants and reduce plant's ability to use free fatty acids as the oxidation substrate for cell reparation.
Collapse
Affiliation(s)
- Olga Olkhovych
- Educational and Scientific Centre “Institute of Biology”, Taras Shevchenko National University of Kyiv, 64, Volodymyrska str., Kyiv,, 01601 Ukraine
| | - Mykola Volkogon
- Educational and Scientific Centre “Institute of Biology”, Taras Shevchenko National University of Kyiv, 64, Volodymyrska str., Kyiv,, 01601 Ukraine
| | - Nataliya Taran
- Educational and Scientific Centre “Institute of Biology”, Taras Shevchenko National University of Kyiv, 64, Volodymyrska str., Kyiv,, 01601 Ukraine
| | - Lyudmyla Batsmanova
- Educational and Scientific Centre “Institute of Biology”, Taras Shevchenko National University of Kyiv, 64, Volodymyrska str., Kyiv,, 01601 Ukraine
| | - Inna Kravchenko
- Educational and Scientific Centre “Institute of Biology”, Taras Shevchenko National University of Kyiv, 64, Volodymyrska str., Kyiv,, 01601 Ukraine
| |
Collapse
|
17
|
Minkler PE, Stoll MSK, Ingalls ST, Kerner J, Hoppel CL. Validated method for the quantification of free and total carnitine, butyrobetaine, and acylcarnitines in biological samples. Anal Chem 2015; 87:8994-9001. [PMID: 26270397 DOI: 10.1021/acs.analchem.5b02198] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A validated quantitative method for the determination of free and total carnitine, butyrobetaine, and acylcarnitines is presented. The versatile method has four components: (1) isolation using strong cation-exchange solid-phase extraction, (2) derivatization with pentafluorophenacyl trifluoromethanesulfonate, (3) sequential ion-exchange/reversed-phase (ultra) high-performance liquid chromatography [(U)HPLC] using a strong cation-exchange trap in series with a fused-core HPLC column, and (4) detection with electrospray ionization multiple reaction monitoring (MRM) mass spectrometry (MS). Standardized carnitine along with 65 synthesized, standardized acylcarnitines (including short-chain, medium-chain, long-chain, dicarboxylic, hydroxylated, and unsaturated acyl moieties) were used to construct multiple-point calibration curves, resulting in accurate and precise quantification. Separation of the 65 acylcarnitines was accomplished in a single chromatogram in as little as 14 min. Validation studies were performed showing a high level of accuracy, precision, and reproducibility. The method provides capabilities unavailable by tandem MS procedures, making it an ideal approach for confirmation of newborn screening results and for clinical and basic research projects, including treatment protocol studies, acylcarnitine biomarker studies, and metabolite studies using plasma, urine, tissue, or other sample matrixes.
Collapse
Affiliation(s)
- Paul E Minkler
- Center for Mitochondrial Diseases, †Department of Pharmacology and ‡Department of Medicine, Case Western Reserve University School of Medicine , Cleveland, Ohio 44106, United States
| | - Maria S K Stoll
- Center for Mitochondrial Diseases, †Department of Pharmacology and ‡Department of Medicine, Case Western Reserve University School of Medicine , Cleveland, Ohio 44106, United States
| | - Stephen T Ingalls
- Center for Mitochondrial Diseases, †Department of Pharmacology and ‡Department of Medicine, Case Western Reserve University School of Medicine , Cleveland, Ohio 44106, United States
| | - Janos Kerner
- Center for Mitochondrial Diseases, †Department of Pharmacology and ‡Department of Medicine, Case Western Reserve University School of Medicine , Cleveland, Ohio 44106, United States
| | - Charles L Hoppel
- Center for Mitochondrial Diseases, †Department of Pharmacology and ‡Department of Medicine, Case Western Reserve University School of Medicine , Cleveland, Ohio 44106, United States
| |
Collapse
|
18
|
Liu Y, Shamsi SA. Combined use of chiral ionic liquid surfactants and neutral cyclodextrins: evaluation of ionic liquid head groups for enantioseparation of neutral compounds in capillary electrophoresis. J Chromatogr A 2014; 1360:296-304. [PMID: 25130088 DOI: 10.1016/j.chroma.2014.07.047] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2014] [Revised: 07/07/2014] [Accepted: 07/16/2014] [Indexed: 11/15/2022]
Abstract
Cyclodextrins (CDs) are most commonly used chiral selectors in capillary electrophoresis (CE). Although the use of neutral CDs and its derivatives have shown to resolve plethora of charged enantiomers, they cannot resolve neutral enantiomers. The use of ionic liquids (ILs) surfactants forming successful complex with CDs present itself an opportunity to resolve neutral enantiomers. In this work, the effect of IL head groups and their complexation ability with heptakis (2,3,6-tri-O-methyl)-β-cyclodextrin (TM-β-CD) was studied for the separation of neutral enantiomers by CE. First, cationic IL type surfactants with different chiral head groups were synthesized. Physicochemical properties such as critical micelle concentration were determined by surface tension, whereas aggregation and polarity were determined by fluorescence spectroscopy. The complexation ability of ILs with TM-β-CD was characterized in the gas phase by CE-mass spectrometry. The influence of the type of ILs head group and its concentration on chiral resolution, resolution per unit time and selectivity were investigated for four structurally diverse neutral compounds. The binding constants of the neutral analytes to the IL-CD complex were estimated by y-reciprocal method. The hydrophobicity of the side chain of the IL head group displayed significant effect on the binding constants and enantioseparations.
Collapse
Affiliation(s)
- Yijin Liu
- Department of Chemistry, Center of Diagnostics and Therapeutics, Georgia State University, Atlanta, GA 30303, United States
| | - Shahab A Shamsi
- Department of Chemistry, Center of Diagnostics and Therapeutics, Georgia State University, Atlanta, GA 30303, United States.
| |
Collapse
|
19
|
Schoonen JW, van Duinen V, Oedit A, Vulto P, Hankemeier T, Lindenburg PW. Continuous-flow microelectroextraction for enrichment of low abundant compounds. Anal Chem 2014; 86:8048-56. [PMID: 24892382 DOI: 10.1021/ac500707v] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
We present a continuous-flow microelectroextraction flow cell that allows for electric field enhanced extraction of analytes from a large volume (1 mL) of continuously flowing donor phase into a micro volume of stagnant acceptor phase (13.4 μL). We demonstrate for the first time that the interface between the stagnant acceptor phase and fast-flowing donor phase can be stabilized by a phaseguide. Chip performance was assessed by visual experiments using crystal violet. Then, extraction of a mixture of acylcarnitines was assessed by off-line coupling to reversed phase liquid chromatography coupled to time-of-flight mass spectrometry, resulting in concentration factors of 80.0 ± 9.2 times for hexanoylcarnitine, 73.8 ± 9.1 for octanoylcarnitine, and 34.1 ± 4.7 times for lauroylcarnitine, corresponding to recoveries of 107.8 ± 12.3%, 98.9 ± 12.3%, and 45.7 ± 6.3%, respectively, in a sample of 500 μL delivered at a flow of 50 μL min(-1) under an extraction voltage of 300 V. Finally, the method was applied to the analysis of acylcarnitines spiked to urine, resulting in detection limits as low as 0.3-2 nM. Several putative endogenous acylcarnitines were found. The current flowing-to-stagnant phase microelectroextraction setup allows for the extraction of milliliter range volumes and is, as a consequence, very suited for analysis of low-abundant metabolites.
Collapse
Affiliation(s)
- Jan-Willem Schoonen
- Division of Analytical Biosciences, Leiden Academic Center for Drug Research, Leiden University , Leiden, The Netherlands
| | | | | | | | | | | |
Collapse
|