1
|
Kaplan RM, Wasserlauf J, Knight BP. Transseptal Access: A Review of Contemporary Tools. J Cardiovasc Electrophysiol 2022; 33:1927-1931. [PMID: 35229417 PMCID: PMC9545840 DOI: 10.1111/jce.15428] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 02/11/2022] [Accepted: 02/14/2022] [Indexed: 11/28/2022]
Abstract
Transseptal left atrial catheterization is routinely used for many common catheter‐based interventions. Tools for transseptal catheterization have advanced over the recent years. Such tools include imaging advances with intracardiac echocardiology as well as an array of needles, wires, and dilators to achieve transseptal access with greater ease and safety. This study will discuss the contemporary tools for transseptal catheterization and guidance for difficult cases.
Collapse
Affiliation(s)
- Rachel M Kaplan
- Section of Electrophysiology, Division of Cardiology, Northwestern University, Feinberg School of Medicine
| | | | - Bradley P Knight
- Section of Electrophysiology, Division of Cardiology, Northwestern University, Feinberg School of Medicine
| |
Collapse
|
2
|
Wasserlauf J, Knight BP. Comparing the safety and effectiveness of dedicated radiofrequency transseptal wires to electrified metal guidewires. J Cardiovasc Electrophysiol 2022; 33:371-379. [PMID: 34978365 PMCID: PMC9303383 DOI: 10.1111/jce.15341] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 11/10/2021] [Accepted: 12/06/2021] [Indexed: 12/04/2022]
Abstract
Background Application of electrocautery to a metal guidewire is used by some operators to perform transseptal puncture (TSP). Commercially available dedicated radiofrequency (RF) guidewires may represent a better alternative. This study compares the safety and effectiveness of electrified guidewires to a dedicated RF wire. Methods TSP was performed on freshly excised porcine hearts using an electrified 0.014″ or 0.032″ guidewire under various power settings and was compared to TSP using a dedicated RF wire with 5 W power (0.035″ VersaCross RF System, Baylis Medical). The primary endpoint was the number of attempts required to achieve TSP. Secondary endpoints included the rate of TSP failure, TSP consistency, the effect of the distance between the tip of the guidewire and the tip of the dilator, and effect of RF power output level. Qualitative secondary endpoints included tissue puncture defect appearance, thermal damage to the TSP guidewire or dilator, and tissue temperature using thermal imaging. Results The RF wire required on average 1.10 ± 0.47 attempts to cross the septum. The 0.014″ electrified guidewire required an overall mean of 2.17 ± 2.36 attempts (2.0 times as many as the RF wire; p < .01), and the 0.032″ electrified guidewire required an overall mean of 3.90 ± 2.93 attempts (3.5 times as many as the RF wire; p < .01). Electrified guidewires had a higher rate of TSP failure, and caused larger defects and more tissue charring than the RF wire. Thermal analysis showed higher temperatures and a larger area of tissue heating with electrified guidewires than the RF wire. Conclusion Fewer RF applications were required to achieve TSP using a dedicated RF wire compared to an electrified guidewire. Smaller defects and lower tissue temperatures were also observed using the RF wire. Electrified guidewires required greater energy delivery and were associated with equipment damage and tissue charring, which may present a risk of thrombus, thermal injury, or scarring.
Collapse
Affiliation(s)
- Jeremiah Wasserlauf
- Department of Internal Medicine, Division of Cardiology, Rush University Medical Center, Chicago, Illinois, USA
| | - Bradley P Knight
- Division of Cardiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
3
|
Morcos R, Megaly M, Desai A, Alkhouli M, Saad M, Luna M, Garcia S, Khalili H, Maini B. The transseptal puncture experience: Safety insights from FDA MAUDE database. Catheter Cardiovasc Interv 2021; 98:E855-E861. [PMID: 33932271 DOI: 10.1002/ccd.29746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 04/12/2021] [Accepted: 04/21/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND There is a paucity of literature on safety and efficacy of various transseptal puncture (TSP) needles. OBJECTIVES To assess the reported mechanisms of failure, complications, and outcomes among the most frequently used transseptal needles in the United States. METHODS We queried the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database between January 2011 and January 2021 for reports on the most commonly used transseptal needles: NRG (Baylis Medical, Montreal, Canada), and BRK (St. Jude, Saint Paul, MN)]. The primary outcome was the mechanism of failure. Secondary outcomes included clinical consequences of device failure. RESULTS The final analysis included 306 reports of failure/complication with TSP needles (NRG n = 70, BRK n = 236). The most commonly reported mode of failure was detachment of the needle component (i.e., clip, hub, stopcock, shaft, spring, or needle tip) (14.7% overall; 17.8% BRK; and 4.3% NRG). Among these reports, cardiac perforation was the most common complication (69.9% overall; 69.1% for BRK; and 72.9% for NRG). Pericardiocentesis was the second most commonly reported complication (45.1% overall; 48.3% for BRK; and 34.3% for NRG). The procedure was successfully completed in 33.3% of all cases (36.4% for BRK and 22.9% for NRG), while surgical conversion was needed in (13.4% overall; 14% for BRK and 11.4% for NRG) of the reports. Death occurred in 3.9% of all cases overall (3.4% for BRK and 5.7% for NRG). CONCLUSIONS Needle detachment was the most common mode of failure, and cardiac perforation was the most common complication reported with TSP needles. Future efforts should focus on innovative TSP needle design, best practice guidelines, including role of imaging guidance, and increased TSP training.
Collapse
Affiliation(s)
- Ramez Morcos
- Division of Cardiology, Florida Atlantic University, Boca Raton, Florida, USA
| | - Michael Megaly
- Division of Cardiology, Banner University Medical Center/ University of Arizona, Phoenix, Arizona, USA
| | - Anand Desai
- Division of Cardiology, Florida Atlantic University, Boca Raton, Florida, USA
| | | | - Marwan Saad
- Cardiovascular Institute, Warren Alpert Medical School of Brown University, Providence, Rhode Island, USA
| | - Michael Luna
- School of Medicine, University of Texas Southwestern, Dallas, Texas, USA
| | - Santiago Garcia
- Minneapolis Heart Institute, Abbott Northwestern Hospital, Minneapolis, Minnesota, USA
| | - Houman Khalili
- Division of Cardiology, Florida Atlantic University, Boca Raton, Florida, USA
| | - Brijeshwar Maini
- Division of Cardiology, Florida Atlantic University, Boca Raton, Florida, USA
| |
Collapse
|
4
|
Sandoval JP, Chaturvedi RR. A simple and fast technique for radiofrequency-assisted perforation of the atrial septum in congenital heart disease. Ann Pediatr Cardiol 2016; 9:39-41. [PMID: 27011690 PMCID: PMC4782466 DOI: 10.4103/0974-2069.171405] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Radiofrequency (RF) assisted perforation of the atrial septum was performed successfully in three infants using a 0.035” RF wire deployed through a Williams right posterior catheter. Balloon atrial septoplasty was performed over the 0.035” RF wire in two of them, shortening the procedural time.
Collapse
Affiliation(s)
- Juan Pablo Sandoval
- Department of Pediatrics, Cardiac Diagnostic and Interventional Unit, The Hospital for Sick Children, The Labatt Family Heart Centre, University of Toronto School of Medicine, Toronto, Ontario, Canada
| | - Rajiv R Chaturvedi
- Department of Pediatrics, Cardiac Diagnostic and Interventional Unit, The Hospital for Sick Children, The Labatt Family Heart Centre, University of Toronto School of Medicine, Toronto, Ontario, Canada
| |
Collapse
|
5
|
Al Maluli H, DeStephan CM, Alvarez RJ, Sandoval J. Atrial Septostomy: A Contemporary Review. Clin Cardiol 2015; 38:395-400. [PMID: 25733325 DOI: 10.1002/clc.22398] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Revised: 01/20/2015] [Accepted: 01/28/2015] [Indexed: 11/10/2022] Open
Abstract
Pulmonary arterial hypertension (PAH) is a rare disease, but it boasts significant morbidity and mortality. Although remarkable achievements have been made in the medical treatment of PAH, there is a role for invasive or surgical procedures in patients with progressive disease despite optimal medical therapy or with no access to such therapy. Atrial septostomy creates a right-to-left intracardiac shunt to decompress the overloaded right ventricle. Despite significant advances to validate and improve this palliative procedure, as well as recent reports of improved outcomes, it is only slowly being adopted. This article aims to detail the history, indications, contraindications, procedural techniques, and outcomes of atrial septostomy. We will also shed light on some of the newer interventions, inspired by the same physiological concept, that are being evaluated as potential palliative modalities in patients with PAH.
Collapse
Affiliation(s)
- Hayan Al Maluli
- Department of Internal Medicine, Cardiology Division, Temple University Hospital, Philadelphia, Pennsylvania
| | - Christine M DeStephan
- Department of Internal Medicine, Temple University Hospital, Philadelphia, Pennsylvania
| | - René J Alvarez
- Department of Internal Medicine, Cardiology Division, Temple University Hospital, Philadelphia, Pennsylvania
| | - Julio Sandoval
- Cardiopulmonary Department, National Cardiology Institute Ignacio Chávez, Mexico City, Mexico
| |
Collapse
|
6
|
Comparison of a Radiofrequency Powered Flexible Needle with a Classic Rigid Brockenbrough Needle for Transseptal Punctures in Terms of Safety and Efficacy. Heart Lung Circ 2015; 24:173-8. [DOI: 10.1016/j.hlc.2014.07.073] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Revised: 04/29/2014] [Accepted: 07/28/2014] [Indexed: 12/26/2022]
|
7
|
Levisay JP, Salinger MH, Feldman T. Antegrade approach for TAVR with total occlusion of the descending aorta. Catheter Cardiovasc Interv 2014; 83:824-30. [PMID: 23857738 DOI: 10.1002/ccd.25124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Revised: 06/17/2013] [Accepted: 07/08/2013] [Indexed: 11/08/2022]
Abstract
The antegrade approach for aortic valve interventions is well known but has not been widely used for transcatheter aortic valve replacement (TAVR) procedures. We encountered a patient with no possibility of retrograde access due to a totally occluded abdominal aorta who had a failed attempt at apical TAVR. We describe antegrade TAVR despite occlusion of the abdominal aorta, with the arterial limb of the requisite veno-arterial loop created using bilateral arm access, a novel version of the previously described antegrade approach.
Collapse
Affiliation(s)
- Justin P Levisay
- NorthShore University HealthSystem, Evanston Hospital, Evanston, Illinois
| | | | | |
Collapse
|
8
|
Norfolk SG, Lederer DJ, Tapson VF. Lung transplantation and atrial septostomy in pulmonary arterial hypertension. Clin Chest Med 2013; 34:857-65. [PMID: 24267309 DOI: 10.1016/j.ccm.2013.09.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This article summarizes the current literature regarding surgical interventions in pulmonary hypertension, excluding chronic thromboembolic pulmonary hypertension. The article discusses the use of atrial septostomy in patients meeting criteria as well as single, double, and heart-lung transplantation.
Collapse
Affiliation(s)
- Stephanie G Norfolk
- Division of Pulmonary and Critical Care, Duke University Medical Center, DUMC 102342, Durham, NC 27710, USA
| | | | | |
Collapse
|
9
|
Hsu JC, Badhwar N, Gerstenfeld EP, Lee RJ, Mandyam MC, Dewland TA, Imburgia KE, Hoffmayer KS, Vedantham V, Lee BK, Tseng ZH, Scheinman MM, Olgin JE, Marcus GM. Randomized trial of conventional transseptal needle versus radiofrequency energy needle puncture for left atrial access (the TRAVERSE-LA study). J Am Heart Assoc 2013; 2:e000428. [PMID: 24045120 PMCID: PMC3835257 DOI: 10.1161/jaha.113.000428] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Transseptal puncture is a critical step in achieving left atrial (LA) access for a variety of cardiac procedures. Although the mechanical Brockenbrough needle has historically been used for this procedure, a needle employing radiofrequency (RF) energy has more recently been approved for clinical use. We sought to investigate the comparative effectiveness of an RF versus conventional needle for transseptal LA access. Methods and Results In this prospective, single‐blinded, controlled trial, 72 patients were randomized in a 1:1 fashion to an RF versus conventional (BRK‐1) transseptal needle. In an intention‐to‐treat analysis, the primary outcome was time required for transseptal LA access. Secondary outcomes included failure of the assigned needle, visible plastic dilator shavings from needle introduction, and any procedural complication. The median transseptal puncture time was 68% shorter using the RF needle compared with the conventional needle (2.3 minutes [interquartile range {IQR}, 1.7 to 3.8 minutes] versus 7.3 minutes [IQR, 2.7 to 14.1 minutes], P=0.005). Failure to achieve transseptal LA access with the assigned needle was less common using the RF versus conventional needle (0/36 [0%] versus 10/36 [27.8%], P<0.001). Plastic shavings were grossly visible after needle advancement through the dilator and sheath in 0 (0%) RF needle cases and 12 (33.3%) conventional needle cases (P<0.001). There were no differences in procedural complications (1/36 [2.8%] versus 1/36 [2.8%]). Conclusions Use of an RF needle resulted in shorter time to transseptal LA access, less failure in achieving transseptal LA access, and fewer visible plastic shavings. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT01209260.
Collapse
Affiliation(s)
- Jonathan C Hsu
- Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, University of California, San Francisco, San Francisco, CA
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Maisano F, La Canna G, Latib A, Godino C, Denti P, Buzzatti N, Taramasso M, Cioni M, Giacomini A, Colombo A, Alfieri O. Transseptal access for MitraClip® procedures using surgical diathermy under echocardiographic guidance. EUROINTERVENTION 2012; 8:579-86. [DOI: 10.4244/eijv8i5a89] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
11
|
Fromentin S, Sarrazin JF, Champagne J, Nault I, Philippon F, Molin F, Blier L, O’Hara G. Prospective comparison between conventional transseptal puncture and transseptal needle puncture with radiofrequency energy. J Interv Card Electrophysiol 2011; 31:237-42. [DOI: 10.1007/s10840-011-9564-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2010] [Accepted: 03/04/2011] [Indexed: 10/18/2022]
|
12
|
Use of a novel needle wire in patients undergoing transseptal puncture associated with severe septal tenting. J Interv Card Electrophysiol 2010; 27:9-13. [PMID: 20072804 DOI: 10.1007/s10840-009-9460-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2009] [Accepted: 11/02/2009] [Indexed: 10/20/2022]
Abstract
INTRODUCTION An increasing number of patients undergo left atrial ablation procedures, since several approaches have proven efficacy in the treatment of atrial fibrillation. Although transseptal catheterization was generally shown be a safe technique, it harbors the principal risk of cardiac injury. Therefore, there is a need for a safe and effective tool to enable transseptal puncture in difficult cases as well. METHODS AND RESULTS In 158 consecutive patients, a transseptal puncture was intended for mapping and ablation of left atrial tachycardias. In seven patients of this series transseptal puncture using different sheaths and needle designs, the operators failed to cross the interatrial septum as a result of severe tenting. Three patients were known to have a septal aneurysm; a redo procedure was performed in two patients. In the remaining patients, there was no obvious explanation for the difficulty in crossing the interatrial septum conventionally. In all seven patients, a 120-cm-long nitinol guidewire ("needle wire") with a 0.014-inch diameter was used to cross the atrial septum with the following idea: after tenting the fossa ovalis with the transseptal dilator and the Brockenbrough needle positioned just inside the tip, effortless advancement of the needle wire perforates the membranous fossa. Unsupported by the needle and dilator, the tip of the wire immediately assumes a "J" shape, rendering it incapable of further tissue penetration after its entry into the left atrium. In all seven patients, the needle wire could be placed into a left pulmonary vein. In five patients, a single attempt was sufficient to reach the left atrium with the wire, two patients needed two and three attempts, respectively. No complications occurred. CONCLUSIONS Additional use of a needle wire to perform transseptal puncture in a subset of patients at higher risk for complications appears safe and effective.
Collapse
|
13
|
Crystal MA, Mirza MA, Benson LN. A radiofrequency transseptal needle: Initial animal studies. Catheter Cardiovasc Interv 2010; 76:769-73. [DOI: 10.1002/ccd.22600] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
14
|
SMELLEY MATTHEWP, SHAH DIPAKP, WEISBERG IAN, KIM SUSANS, LIN ALBERTC, BESHAI JOHNF, BURKE MARTINC, KNIGHT BRADLEYP. Initial Experience Using a Radiofrequency Powered Transseptal Needle. J Cardiovasc Electrophysiol 2010; 21:423-7. [DOI: 10.1111/j.1540-8167.2009.01656.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
15
|
SHAH ASHOKJ, JANES RENEE, HOLLIDAY JEFFREY, THAKUR RANJAN. Radiofrequency Transseptal Catheter Electrode Fracture. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2010; 33:e57-8. [DOI: 10.1111/j.1540-8159.2010.02708.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
16
|
Capulzini L, Paparella G, Sorgente A, de Asmundis C, Chierchia GB, Sarkozy A, Muller-Burri A, Yazaki Y, Roos M, Brugada P. Feasibility, safety, and outcome of a challenging transseptal puncture facilitated by radiofrequency energy delivery: a prospective single-centre study. Europace 2010; 12:662-7. [DOI: 10.1093/europace/euq019] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
17
|
TZEIS STYLIANOS, ANDRIKOPOULOS GEORGE, DEISENHOFER ISABEL, HO SIEWYEN, THEODORAKIS GEORGE. Transseptal Catheterization: Considerations and Caveats. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2010; 33:231-42. [DOI: 10.1111/j.1540-8159.2009.02598.x] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
18
|
Knecht S, Jaïs P, Nault I, Wright M, Matsuo S, Madaffari A, Lellouche N, O'Neill MD, Derval N, Deplagne A, Bordachar P, Sacher F, Hocini M, Clémenty J, Haïssaguerre M. Radiofrequency Puncture of the Fossa Ovalis for Resistant Transseptal Access. Circ Arrhythm Electrophysiol 2008; 1:169-74. [DOI: 10.1161/circep.108.788000] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Sébastien Knecht
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Pierre Jaïs
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Isabelle Nault
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Matthew Wright
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Seiichiro Matsuo
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Antonio Madaffari
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Nicolas Lellouche
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Mark D. O'Neill
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Nicolas Derval
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Antoine Deplagne
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Pierre Bordachar
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Frederic Sacher
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Mélèze Hocini
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Jacques Clémenty
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| | - Michel Haïssaguerre
- From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France
| |
Collapse
|
19
|
Rillig A, Meyerfeldt U, Birkemeyer R, Treusch F, Kunze M, Jung W. Persistent iatrogenic atrial septal defect after pulmonary vein isolation. J Interv Card Electrophysiol 2008; 22:177-81. [DOI: 10.1007/s10840-008-9257-7] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2008] [Accepted: 04/01/2008] [Indexed: 10/22/2022]
|
20
|
Elagha AA, Kim AH, Kocaturk O, Lederman RJ. Blunt atrial transseptal puncture using excimer laser in swine. Catheter Cardiovasc Interv 2008; 70:585-90. [PMID: 17896413 PMCID: PMC2726716 DOI: 10.1002/ccd.21257] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVES We describe a new approach that may enhance safety of atrial transseptal puncture using a commercially available laser catheter that is capable of perforation only when energized. We test this approach in swine. BACKGROUND Despite wide application, conventional needle transseptal puncture continues to risk inadvertent nontarget perforation and its consequences. METHODS We used a commercial excimer laser catheter (0.9-mm Clirpath, Spectranetics). Perforation force was compared in vitro with a conventional Brockenbrough needle. Eight swine underwent laser transseptal puncture under X-ray fluoroscopy steered using a variety of delivery catheters. RESULTS The 0.9-mm laser catheter traversed in vitro targets with reduced force compared with a Brockenbrough needle. In vitro, the laser catheter created holes that were 25-30% larger than the Brockenbrough needle. Laser puncture of the atrial septum was successful and accurate in all animals, evidenced by oximetry, pressure, angiography, and necropsy. The laser catheter was steered effectively using a modified Mullins introducer sheath and using two different deflectable guiding catheters. The mean procedure time was 15 +/- 6 min, with an average 3.0 +/- 0.8 sec of laser activation. There were no adverse sequelae after prolonged observation. Necropsy revealed discrete 0.9-mm holes in all septae. CONCLUSION Laser puncture of the interatrial septum is feasible and safe in swine, using a blunt laser catheter that perforates tissues in a controlled fashion.
Collapse
Affiliation(s)
- Abdalla A Elagha
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | | | | | | |
Collapse
|
21
|
Abstract
Surgical therapies for the treatment of pulmonary arterial hypertension typically are reserved for patients who are deemed to be refractory to medical therapy and have evidence of progressive right-sided heart failure. Atrial septostomy, a primarily palliative procedure, may stave off hemodynamic collapse from right-sided heart failure long enough to permit a more definitive surgical treatment such as lung or combined heart-lung transplantation. This article discusses indications for and results of atrial septostomy and lung and heart-lung transplantation in patients who have pulmonary arterial hypertension.
Collapse
Affiliation(s)
- Jeffrey S Sager
- Lung Transplantation Program, Pulmonary, Allergy and Critical Care Division, University of Pennsylvania Medical Center, 828 West Gates Building, 3600 Spruce Street, Philadelphia, PA 19104, USA.
| | | |
Collapse
|
22
|
Baerlocher MO, Asch MR, Myers A. Successful Recanalization of a Longstanding Complete Left Subclavian Vein Occlusion by Radiofrequency Perforation with Use of a Radiofrequency Guide Wire. J Vasc Interv Radiol 2006; 17:1703-6. [PMID: 17057015 DOI: 10.1097/01.rvi.0000243637.23923.a7] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Treatment with radiofrequency (RF) energy can be used to ablate or perforate tissues. The latter involves lower power, higher voltage, and much shorter treatment time, and it is thought to induce much less collateral tissue damage. To date, RF perforation has been successfully used for various cardiac interventions; however, to our knowledge, there has not been a report of its use for peripheral vascular disease. This report describes the successful recanalization of a longstanding occlusion of a left subclavian vein in a 73-year-old woman with polycystic kidney disease and end-stage renal disease undergoing chronic hemodialysis treatment via an upper-extremity arteriovenous fistula. Multiple previous attempts at mechanical recanalization were unsuccessful. Recanalization was achieved by RF perforation with use of a PowerWire RF guide wire.
Collapse
Affiliation(s)
- Mark O Baerlocher
- Department of Interventional Radiology, University Health Network and Mount Sinai Hospital, University of Toronto, Ontario, Canada.
| | | | | |
Collapse
|