1
|
Baruteau AE, Méot M, Benbrik N, Grunenwald C, Lwin N, Patkai J, Rozé JC, Bonnet D, Malekzadeh-Milani S. Device Closure of Hemodynamically Significant Patent Ductus Arteriosus in Premature Infants. JACC. ADVANCES 2024; 3:101211. [PMID: 39263415 PMCID: PMC11388744 DOI: 10.1016/j.jacadv.2024.101211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Accepted: 06/24/2024] [Indexed: 09/13/2024]
Abstract
The patent ductus arteriosus is a very common condition in preterm infants, and a hemodynamically significant patent ductus arteriosus increases morbidity and mortality in these vulnerable patients. However, despite numerous randomized controlled trials, there is no consensus regarding management. Medical therapy is typically offered as first-line treatment, although it yields limited success and carries the potential for severe adverse events. In recent years, there has been rapid development in transcatheter patent ductus arteriosus closure primary with the use of the Amplatzer Piccolo Occluder, and this has gained widespread acceptance as a safe and effective alternative to surgical ligation in extremely low-birth-weight infants weighing over 700 g. This article aims to provide an appraisal of the patient selection process, a step-by-step procedural guide, and a comprehensive review of the outcomes associated with this approach.
Collapse
Affiliation(s)
- Alban-Elouen Baruteau
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, Nantes Université, CHU Nantes, FHU PreciCare, Nantes, France
- Nantes Université, CHU Nantes, INSERM, CIC FEA 1413, Nantes, France
- Nantes Université, CHU Nantes, CNRS, INSERM, l'institut du thorax, Nantes, France
- Nantes Université, INRAE, UMR 1280, PhAN, Nantes, France
| | - Mathilde Méot
- M3C-Necker, Department of Pediatric and Congenital Cardiology, Hôpital Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France
| | - Nadir Benbrik
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, Nantes Université, CHU Nantes, FHU PreciCare, Nantes, France
| | - Céline Grunenwald
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, Nantes Université, CHU Nantes, FHU PreciCare, Nantes, France
| | - Naychi Lwin
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, Nantes Université, CHU Nantes, FHU PreciCare, Nantes, France
- Nantes Université, CHU Nantes, INSERM, CIC FEA 1413, Nantes, France
| | - Juliana Patkai
- Department of Neonatal Medicine, Cochin-Port Royal Hospital, FHU PREMA, APHP, Paris, France
| | | | - Damien Bonnet
- M3C-Necker, Department of Pediatric and Congenital Cardiology, Hôpital Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France
- University Paris Cité, Paris, France
| | - Sophie Malekzadeh-Milani
- M3C-Necker, Department of Pediatric and Congenital Cardiology, Hôpital Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France
| |
Collapse
|
2
|
Tabb C, Aggarwal S, Bajaj M, Natarajan G. Comparative Effectiveness of Surgical Ligation and Catheter Closure of Patent Ductus Arteriosus in Preterm Infants. Pediatr Cardiol 2024; 45:1515-1523. [PMID: 37316609 DOI: 10.1007/s00246-023-03199-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Accepted: 05/25/2023] [Indexed: 06/16/2023]
Abstract
To evaluate the association, if any, between closure modality (surgical ligation SL vs. catheter CC) of a hemodynamically significant patent ductus arteriosus (PDA), after failure of or contraindication to medical therapy, and immediate procedural complications, and post-procedure physiologic status in preterm (gestational age < 32 weeks) infants. In this single-center retrospective cohort study, data were accessed on infants < 32 weeks gestation, who underwent SL or CC of PDA, born from 2019-2021. The choice of modality was determined by parents, after they were provided information on both procedures. Our cohort (n = 112) included 36 (32.1%) infants who underwent SL while 76 (67.9%) underwent CC. The SL group of infants were significantly more immature at birth, younger on admission to the level IV NICU and received more mean (SD) surfactant doses than the CC group. Higher proportions of infants in the SL group had 5-min Apgar scores ≤ 5, seizures, severe intracranial hemorrhage and had received medical therapy for PDA. Both procedures were highly efficacious, with 1 unsuccessful device placement attempt and had low associated adverse events. Two (2.6%) infants had device migration 24 h after CC. SL was associated with a higher rate of immediate postoperative hypothermia whereas, in the CC group, mean airway pressure was significantly lower 48 h after, compared to before the procedure. SL and CC are comparable in short-term efficacy and safety for PDA closure. Long-term outcomes data are needed following both procedures.
Collapse
Affiliation(s)
- Carl Tabb
- Division of Neonatology, Central Michigan University, Children's Hospital of Michigan, 3901 Beaubien Blvd, PediatricsDetroit, CentralMI, USA
| | - Sanjeev Aggarwal
- Division of Pediatric Cardiology, Central Michigan University, Children's Hospital of Michigan, Detroit, MI, USA
| | - Monika Bajaj
- Division of Neonatology, Central Michigan University, Children's Hospital of Michigan, 3901 Beaubien Blvd, PediatricsDetroit, CentralMI, USA
| | - Girija Natarajan
- Division of Neonatology, Central Michigan University, Children's Hospital of Michigan, 3901 Beaubien Blvd, PediatricsDetroit, CentralMI, USA.
| |
Collapse
|
3
|
Molloy A, Tailor N, Naik R, Swaminathan N, Absi M, Merlocco A, Johnson J, Sathanandam S. Off-label uses of the Amplatzer Piccolo Occluder in children with congenital and acquired heart diseases. Future Cardiol 2024; 20:459-470. [PMID: 39234889 PMCID: PMC11486072 DOI: 10.1080/14796678.2024.2355057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 05/10/2024] [Indexed: 09/06/2024] Open
Abstract
Aim: The Amplatzer Piccolo Occluder (APO) is approved for patent ductus arteriosus (PDA) occlusion in infants weighing >700 g but could offer versatility to treat other lesions.Methods: Retrospective review of children in whom APO was utilized for defects other than PDA between January 2022 and June 2023.Results: The APO was used in nine patients; three for ventricular septal defects, four with coronary fistulas, one for a ventricular pseudoaneurysm and one where APO deployed within a fenestration of a previously placed Amplatzer Septal Occluder. All nine patients had successful occlusions without complications.Conclusion: The APO is a versatile device that can be used to treat various small diameter lesions in children besides the PDA for which it is currently approved for.
Collapse
Affiliation(s)
- Ashley Molloy
- Department of Pediatrics, Division of Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, TN, USA
| | - Neil Tailor
- Department of Pediatrics, Division of Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, TN, USA
| | - Ronak Naik
- Department of Pediatrics, Division of Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, TN, USA
| | - Nithya Swaminathan
- Department of Pediatrics, Division of Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, TN, USA
| | - Mohammed Absi
- Department of Pediatrics, Division of Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, TN, USA
| | - Anthony Merlocco
- Department of Pediatrics, Division of Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, TN, USA
| | - Jason Johnson
- Department of Pediatrics, Division of Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, TN, USA
| | - Shyam Sathanandam
- Department of Pediatrics, Division of Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, TN, USA
| |
Collapse
|
4
|
Zhang K, Yang L, Zhang R, Ma J, Cheng M, Yang P, Xiang P, Li M, Zhou X. Feasibility and Success of Muscular Ventricular Septal Defect Occluders and Mushroom-Shaped Occluders in Transcatheter Patent Ductus Arteriosus Closure in Low-Weight Children: A Propensity Score-Matched Retrospective Analysis from a Chinese National Regional Health Center. Cardiology 2024:1-9. [PMID: 39089228 DOI: 10.1159/000540685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 07/26/2024] [Indexed: 08/03/2024]
Abstract
INTRODUCTION Muscular ventricular septal defect occluders (MVSDOs) have been attempted as an option in low-weight patients with patent ductus arteriosus (PDA). However, few studies have assessed the safety of transcatheter patent ductus arteriosus closure (TCPC) using MVSDO. Therefore, we compared the outcomes in low-weight patients who used MVSDO and mushroom-shaped occluder (MSO). METHODS Medical records of children under 10 kg (n = 417) who underwent TCPC from 2015 to 2021 at a Chinese health center were reviewed. They were divided into MSO (n = 372) and MVSDO (n = 45) groups. A 1:1 propensity score matching (PSM) was done considering gender, height, weight, body surface area (BSA), PDA diameter, and BSA-corrected PDA diameter. RESULTS All 45 children in the MVSDO group (mean weight: 5.92 ± 1.32 kg) achieved successful immediate occlusion. One case in the MVSDO group experienced device migration within 24 h requiring unplanned surgery. MVSDO significantly ameliorated pulmonary artery hypertension. After PSM, each group comprised 41 children. The MVSDO group had a smaller effect on platelet counts (MVSDO vs. MSO = 259.85 ± 114.82 vs. 356.12 ± 134.37, p < 0.001), a reduced incidence of thrombocytopenia (MVSDO vs. MSO = 2/41 vs. 7/41, p = 0.001), and a higher rate of residual shunting (MVSDO vs. MSO = 16/41 vs. 5/41, p = 0.005), compared with the MSO group. Thrombocytopenia resolved during hospitalization and micro-shunts disappeared by 6 months. No pulmonary artery or descending aortic secondary stenosis was observed in 1-year follow-up. CONCLUSIONS MVSDO used in low-weight children is feasible, with high success and satisfactory postoperative and short-term follow-up outcomes, including lower thrombocytopenia incidence, compared to MSO. Further long-term studies with larger samples are recommended.
Collapse
Affiliation(s)
- Kaijun Zhang
- Department of Cardiovascular Medicine, Children's Hospital of Chongqing Medical University, Chongqing, China,
- National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Key Laboratory of Children's Important Organ Development and Diseases of Chongqing Municipal Health Commission, Chongqing, China,
- National Clinical Key Cardiovascular Specialty, Chongqing, China,
| | - Le Yang
- Department of Pediatrics, Chengdu Seventh People's Hospital (Affiliated Cancer Hospital of Chengdu Medical College), Chengdu, China
| | - Rensen Zhang
- National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Key Laboratory of Children's Important Organ Development and Diseases of Chongqing Municipal Health Commission, Chongqing, China
- Department of General Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Jingdong Ma
- Chongqing Medical University, Chongqing, China
| | - Min Cheng
- National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Key Laboratory of Children's Important Organ Development and Diseases of Chongqing Municipal Health Commission, Chongqing, China
- Department of Neurology, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Penghui Yang
- Department of Cardiovascular Medicine, Children's Hospital of Chongqing Medical University, Chongqing, China
- National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Key Laboratory of Children's Important Organ Development and Diseases of Chongqing Municipal Health Commission, Chongqing, China
- National Clinical Key Cardiovascular Specialty, Chongqing, China
| | - Ping Xiang
- Department of Cardiovascular Medicine, Children's Hospital of Chongqing Medical University, Chongqing, China
- National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Key Laboratory of Children's Important Organ Development and Diseases of Chongqing Municipal Health Commission, Chongqing, China
- National Clinical Key Cardiovascular Specialty, Chongqing, China
| | - Mi Li
- Department of Cardiovascular Medicine, Children's Hospital of Chongqing Medical University, Chongqing, China
- National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Key Laboratory of Children's Important Organ Development and Diseases of Chongqing Municipal Health Commission, Chongqing, China
- National Clinical Key Cardiovascular Specialty, Chongqing, China
| | - Xue Zhou
- Department of Cardiovascular Medicine, Children's Hospital of Chongqing Medical University, Chongqing, China
- National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Key Laboratory of Children's Important Organ Development and Diseases of Chongqing Municipal Health Commission, Chongqing, China
- National Clinical Key Cardiovascular Specialty, Chongqing, China
| |
Collapse
|
5
|
Bischoff AR, Backes CH, Rivera B, Jasani B, Patel F, Cheung E, Sathanandam S, Philip R, McNamara PJ. Cardiorespiratory Instability after Percutaneous Patent Ductus Arteriosus Closure: A Multicenter Cohort Study. J Pediatr 2024; 271:114052. [PMID: 38615941 DOI: 10.1016/j.jpeds.2024.114052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Revised: 04/01/2024] [Accepted: 04/08/2024] [Indexed: 04/16/2024]
Abstract
OBJECTIVE To evaluate postprocedural clinical characteristics of preterm infants undergoing transcatheter patent ductus arteriosus (PDA) closure, including oxygenation/ventilation failure and cardiovascular compromise. STUDY DESIGN Multicenter retrospective cohort study of preterm infants who were ≤2 kg at the time of percutaneous PDA closure between August 2018 and July 2021. Indices of cardiorespiratory stability were collected pre-closure, immediately post-closure, and subsequently averaged every 4 hours for the first 24 hours post-procedure. The primary outcome was incidence of post-transcatheter cardiorespiratory syndrome: composite of hemodynamic instability (defined by systemic hypotension, systemic hypertension, or use of new inotropes/vasopressors in the first 24 hours after catheterization) and at least one of the following: (i) ventilation failure or (ii) oxygenation failure. RESULTS A total of 197 patients were included with a median [IQR] age and weight at catheterization of 34 [25, 43] days and 1090 [900, 1367] grams, respectively. The primary composite outcome of post-transcatheter cardiorespiratory syndrome was reported in 46 (23.3%). CONCLUSION Post-transcatheter cardiorespiratory syndrome is characterized primarily by systemic hypertension and oxygenation failure, with a very low incidence of hypotension and need for inotropes.
Collapse
Affiliation(s)
- Adrianne R Bischoff
- Division of Neonatology, Department of Pediatrics, University of Iowa, Iowa City, IA
| | - Carl H Backes
- Department of Pediatrics, Nationwide Children's Hospital, Columbus, OH
| | - Brian Rivera
- Department of Pediatrics, Nationwide Children's Hospital, Columbus, OH
| | - Bonny Jasani
- Department of Pediatrics, The Hospital for Sick Children, Toronto, ON
| | - Foram Patel
- Department of Pediatrics, The Hospital for Sick Children, Toronto, ON
| | - Erica Cheung
- Department of Pediatrics, The Hospital for Sick Children, Toronto, ON
| | - Shyam Sathanandam
- Department of Pediatrics, University of Tennessee Health Science Center, Memphis, TN
| | - Ranjit Philip
- Department of Pediatrics, University of Tennessee Health Science Center, Memphis, TN
| | - Patrick J McNamara
- Division of Neonatology, Department of Pediatrics, University of Iowa, Iowa City, IA; Department of Internal Medicine, University of Iowa, Iowa City, IA.
| |
Collapse
|
6
|
Parkerson S, Sathanandam S, Molloy A. Patent Ductus Arteriosus Occlusion in Premature Infants. Interv Cardiol Clin 2024; 13:355-368. [PMID: 38839169 DOI: 10.1016/j.iccl.2024.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2024]
Abstract
Transcatheter ductal closure has proven to be safe and effective to occlude the patent ductus arteriosus (PDA) in premature infants. We have developed a robust multidisciplinary PDA program. After gaining experience performing transcatheter ductal closure in the cardiac catheterization laboratory, we transitioned to performing the procedure at the patient's bedside in the neonatal intensive care unit using echocardiographic guidance. The bedside approach has the potential to expand this therapy to patients who currently undergo expectant PDA management because of lack of availability of this therapy, and allow for earlier referral, which will reduce time of exposure to this pathologic shunt.
Collapse
Affiliation(s)
- Sarah Parkerson
- Department of Pediatrics, Division of Pediatric Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, 51 N Dunlap street, Memphis, TN 38105, USA
| | - Shyam Sathanandam
- Department of Pediatrics, Division of Pediatric Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, 51 N Dunlap street, Memphis, TN 38105, USA.
| | - Ashley Molloy
- Department of Pediatrics, Division of Pediatric Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, 51 N Dunlap street, Memphis, TN 38105, USA
| |
Collapse
|
7
|
Loeffler KA, Behere SP, Williams PK, Nakamura Y, Burkhart HM, Campbell MD. Reduced morbidity with early surgical ligation of patent ductus arteriosus in extremely low birth weight infants: a retrospective single-centre study. Cardiol Young 2024; 34:1279-1284. [PMID: 38196381 DOI: 10.1017/s1047951123004432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
Abstract
INTRODUCTION Failure of the patent ductus arteriosus to close is common among extremely low birth weight neonates and has been associated with increased morbidities. The objective of this study was to compare outcomes between early and late surgical ligation in extremely low birth weight patients. METHODS This was a single-centre retrospective cohort study of infants who required surgical closure of patent ductus arteriosus between January 2017 and August 2022. RESULTS A total of 43 neonates were identified with birth weight less than 1 kg that underwent surgical patent ductus arteriosus ligation. Compared to the late ligation group, the early ligation group experienced fewer total days of mechanical ventilation (43.9 days vs. 97.2 days, p < 0.05) and a shorter length of hospital stay (114.2 days vs. 169.0 days, p < 0.05). CONCLUSION Early surgical ligation of haemodynamically significant patent ductus arteriosus in extremely low birth weight neonates may improve hospital morbidity, including improved ventilatory outcomes and a shorter length of stay.
Collapse
Affiliation(s)
| | - Shashank P Behere
- University of Oklahoma Health Science Center, Oklahoma City, OK, USA
| | | | - Yuki Nakamura
- University of Oklahoma Health Science Center, Oklahoma City, OK, USA
| | - Harold M Burkhart
- University of Oklahoma Health Science Center, Oklahoma City, OK, USA
| | | |
Collapse
|
8
|
Lembo C, Méot M, Mellul K, Aryafar A, Szézépanski I, Iacobelli S, Kermorvant-Duchemin E, Bonnet D, Malekzadeh-Milani S, Lapillonne A. Renal function after ductus arteriosus transcatheter closure with or without angiography in very preterm infants. Acta Paediatr 2024; 113:955-961. [PMID: 38180109 DOI: 10.1111/apa.17101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 12/27/2023] [Accepted: 12/29/2023] [Indexed: 01/06/2024]
Abstract
AIM Transcatheter closure of the patent ductus arteriosus (TCPDA) is increasingly used in preterm infants as an alternative to surgical ligation. However, clinically ill preterm infants are at risk of contrast nephropathy due to the angiography contrast agents used during the procedure. METHODS We performed a single-centre before-and-after comparative study in VLBW infants to compare the kinetics of serum creatinine during the first 4 days after TCPDA with or without angiography. RESULTS 69 patients were included and divided into two groups: TCPDA with (contrast+; n = 37) and without (contrast-, n = 32) use of contrast agent. The median dose [range] of contrast agent was 1.0 mL/kg [0.6-2.4 mL/kg]. The change in serum creatinine level between day 2 to 4 after TCPCA and baseline decreased in the contrast- group (-17% [-46%; 18%]), while it increased in the contrast+ group (7% [-24%; 202%] p = 0.002). Comparison of blood urea levels between groups showed similar significant differences. The change in serum creatinine between day 2 to 4 and baseline was significantly correlated with the dose of contrast agent (r2 = 0.682; p < 0.001). CONCLUSION The use of contrast agents during TCPDA can potentially harm the renal function of very preterm infants. Therefore, we advise minimising or avoiding the use of contrast agents.
Collapse
Affiliation(s)
- Chiara Lembo
- Department of Neonatology, APHP, Necker-Enfants Malades Hospital, Paris, France
| | - Mathilde Méot
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, APHP Hôpital Necker-Enfants Malades, Paris, France
| | - Kelly Mellul
- Department of Neonatology, APHP, Necker-Enfants Malades Hospital, Paris, France
| | - Annahita Aryafar
- Department of Neonatology, APHP, Necker-Enfants Malades Hospital, Paris, France
| | - Isabelle Szézépanski
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, APHP Hôpital Necker-Enfants Malades, Paris, France
| | - Silvia Iacobelli
- Réanimation Néonatale et Pédiatrique, Néonatologie, CHU La Réunion, Saint Pierre, France
| | - Elsa Kermorvant-Duchemin
- Department of Neonatology, APHP, Necker-Enfants Malades Hospital, Paris, France
- UFR de Médecine, Université Paris Cité, Paris, France
| | - Damien Bonnet
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, APHP Hôpital Necker-Enfants Malades, Paris, France
- UFR de Médecine, Université Paris Cité, Paris, France
| | - Sophie Malekzadeh-Milani
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, APHP Hôpital Necker-Enfants Malades, Paris, France
| | - Alexandre Lapillonne
- Department of Neonatology, APHP, Necker-Enfants Malades Hospital, Paris, France
- UFR de Médecine, Université Paris Cité, Paris, France
| |
Collapse
|
9
|
Duboue PM, Padovani P, Bouteiller XP, Martin-Kabore F, Benbrik N, Gronier CG, Bouissou A, Garnier E, Mitanchez D, Flamant C, Rozé JC, Baruteau AE, Lefort B. Post-ligation cardiac syndrome after surgical versus transcatheter closure of patent ductus arteriosus in low body weight premature infants: a multicenter retrospective cohort study. Eur J Pediatr 2024; 183:2193-2201. [PMID: 38381375 DOI: 10.1007/s00431-024-05481-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 02/06/2024] [Accepted: 02/10/2024] [Indexed: 02/22/2024]
Abstract
Transcatheter patent ductus arteriosus (PDA) closure is a safe and effective alternative to surgical ligation in low-body-weight infants. Post-ligation cardiac syndrome (PLCS) is defined as severe hemodynamic and respiratory collapse within 24 h of PDA closure, requiring initiation or an increase of an inotropic agent by > 20% of preligation dosing and an absolute increase of at least 20% in ventilation parameters compared with the preoperative value. Whilst PLCS is routinely observed after surgery, its incidence remains poorly described following transcatheter closure. This study aimed to compare the incidence of PLCS after surgical versus transcatheter closure of PDA in low-body-weight premature infants. Propensity scores were used to compare surgical (N = 78) and transcatheter (N = 76) groups of preterm infants who underwent PDA closure at a procedural weight less than 2000 g in two tertiary institutions between 2009 and 2021. The primary outcome was the incidence of PLCS. Secondary outcomes included overall mortality before discharge, risk factors for PLCS, and post-procedural complications. Procedural success was 100% in both groups. After matching, transcatheter group experienced no PLCS vs 15% in the surgical group (p = 0.012). Furthermore, overall mortality (2% vs 17%; p = 0.03) and major complications (2% vs 23%; p = 0.002) were higher in the surgical group. Surgery (100% vs 47%; p < 0.01), gestation age (25 ± 1 vs 26 ± 2 weeks, p < 0.05) and inotropic support before closure (90% vs 29%; p < 0.001) were associated with PLCS occurrence. Conclusion: Transcatheter PDA closure may be equally effective but safer than surgical PDA closure in low-body-weight premature infants. What is Known: • Post-ligation cardiac syndrome is a serious and common complication of surgical closure of the ductus arteriosus in preterm infants. • Transcatheter closure of preterm ductus arteriosus is a safe and effective technique that is becoming more and more common worldwide. What is New: • Device closure is safer than surgical ligation for patent ductus arteriosus closure in preterm infants and may be the first-line non-pharmacological therapeutic option in this indication in experienced teams. • Our findings should encourage neonatologists and pediatric cardiologists to start and/or strengthen a durable interventional program for transcatheter PDA closure in premature infants.
Collapse
MESH Headings
- Humans
- Ductus Arteriosus, Patent/surgery
- Retrospective Studies
- Infant, Newborn
- Female
- Ligation/methods
- Ligation/adverse effects
- Male
- Cardiac Catheterization/methods
- Cardiac Catheterization/adverse effects
- Infant, Premature
- Postoperative Complications/epidemiology
- Postoperative Complications/etiology
- Infant, Low Birth Weight
- Incidence
- Cardiac Surgical Procedures/adverse effects
- Cardiac Surgical Procedures/methods
- Syndrome
- Propensity Score
- Septal Occluder Device
- Risk Factors
- Infant, Premature, Diseases/surgery
- Infant, Premature, Diseases/etiology
- Infant, Premature, Diseases/therapy
- Infant, Premature, Diseases/epidemiology
Collapse
Affiliation(s)
| | - Paul Padovani
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, FHU PreciCare, CHU Nantes, Nantes University, Nantes, France
- INSERM, CIC FEA 1413, Nantes University, Nantes, France
| | - Xavier Paul Bouteiller
- Department of Cardiology, Electrophysiology and Heart Modelling Institute, CHU Bordeaux, IHU Liryc, Bordeaux University Foundation, Pessac, France
| | | | - Nadir Benbrik
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, FHU PreciCare, CHU Nantes, Nantes University, Nantes, France
- INSERM, CIC FEA 1413, Nantes University, Nantes, France
| | - Céline Grunenwald Gronier
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, FHU PreciCare, CHU Nantes, Nantes University, Nantes, France
- INSERM, CIC FEA 1413, Nantes University, Nantes, France
| | - Antoine Bouissou
- Department of Neonatology, CHU Tours, Tours University, Tours, France
| | - Elodie Garnier
- Department of Neonatology, CHU Tours, Tours University, Tours, France
- Institut Des Cardiopathies Congénitales de Tours, FHU PreciCare, CHU Tours, Tours University, Tours, France
| | - Delphine Mitanchez
- Department of Neonatology, CHU Tours, Tours University, Tours, France
- INSERM UMR_S 938 Centre de Recherche Saint Antoine, Paris, France
| | - Cyril Flamant
- Department of Neonatology, CHU Nantes, Nantes University, Nantes, France
| | | | - Alban-Elouen Baruteau
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, FHU PreciCare, CHU Nantes, Nantes University, Nantes, France
- INSERM, CIC FEA 1413, Nantes University, Nantes, France
- CNRS, INSERM, L'institut du Thorax, CHU Nantes, Nantes University, Nantes, France
| | - Bruno Lefort
- Institut Des Cardiopathies Congénitales de Tours, FHU PreciCare, CHU Tours, Tours University, Tours, France.
- UMR 1069, INSERM, Tours University, Tours, France.
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, Clocheville Hospital, CHRU Tours, 49, Boulevard Béranger, 37000, Tours, France.
| |
Collapse
|
10
|
Melchior CDS, Neves GR, de Oliveira BL, Toguchi AC, Lopes JC, Pavione MA, Enríquez SKT. Percutaneous closure of patent ductus arteriosus versus surgical treatment in low-birth-weight preterms: a systematic review and meta-analysis. Cardiol Young 2024; 34:705-712. [PMID: 38329109 DOI: 10.1017/s1047951123004353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/09/2024]
Abstract
INTRODUCTION The optimal management of a patent ductus arteriosus in a population of preterm infants is controversial. Traditionally, when the patent ductus arteriosus does not close either with conservative treatment or in response to pharmacological therapy, the only option is surgical closure. However, transcatheter occlusion might provide a therapeutic alternative. METHODS We searched PubMed, Embase, and Cochrane databases for non-randomised and randomised controlled trials that compared transcatheter percutaneous closure of patent ductus arteriosus with surgical ligation in low-birth-weight preterm infants (<2,500 g). A random-effects model was used for outcomes with high heterogeneity. RESULTS We included twelve studies comprising 4,668 low-birth-weight preterm infants, of whom 966 (20.7%) were in the transcatheter percutaneous closure group, and 3,702 (79.3%) patients were included in the surgical group. All-cause mortality (OR 0.28; 95% confidence interval 0.18-0.423; p < 0.00001; I2 = 0%) and haemodynamic instability (OR 0.10; 95% confidence interval 0.05-0.21; p < 0.001; I2 = 14%) were significantly lower in the transcatheter percutaneous closure group. There was no significant difference between transcatheter and surgical patent ductus arteriosus closure for the outcomes of bronchopulmonary dysplasia (0.93; 95% confidence interval 0.46-1.87; p = 0.83; I2 = 0%) and major complications (OR 0.76; 95% confidence interval 0.34-1.69; p = 0.51; I2 = 43%). CONCLUSION These findings suggest that transcatheter patent ductus arteriosus closure in preterm infants under 2,500 g is a safe and effective alternative to surgical treatment. There was a substantial reduction in all-cause mortality and haemodynamic instability with transcatheter intervention compared to surgical closure.
Collapse
|
11
|
Pugnaloni F, Doni D, Lucente M, Fiocchi S, Capolupo I. Ductus Arteriosus in Fetal and Perinatal Life. J Cardiovasc Dev Dis 2024; 11:113. [PMID: 38667731 PMCID: PMC11050351 DOI: 10.3390/jcdd11040113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 03/30/2024] [Accepted: 03/30/2024] [Indexed: 04/28/2024] Open
Abstract
The ductus arteriosus represents an essential vascular structure connecting the pulmonary artery and the aorta. Over the past decades, there has been substantial advancement in our understanding of both the fundamental and clinical aspects of the ductus arteriosus. In particular, the clarification of the regulatory mechanisms governing ductal patency in critical stages such as the fetal and the perinatal period has enabled optimal management of both physiological and pathological conditions in which the ductus arteriosus plays a crucial role. Furthermore, a more in-depth understanding of the regulatory mechanisms controlling this fundamental structure has facilitated the development of advanced therapeutic strategies and personalized interventions. In the present review, we provide a comprehensive overview of the ductus arteriosus during fetal and perinatal life, encompassing its physiological functions, pathological conditions, and clinical implications. Through this examination, we aim to contribute to a broader understanding of the ductus arteriosus' role in these critical developmental stages and its significance in clinical practice.
Collapse
Affiliation(s)
- Flaminia Pugnaloni
- Neonatal Intensive Care Unit, Fetal Neonatal and Cardiological Science Research Area, “Bambino Gesù” Children’s Hospital, IRCCS, 00165 Rome, Italy;
| | - Daniela Doni
- Neonatal Intensive Care Unit, Fondazione IRCCS San Gerardo Dei Tintori, 20900 Monza, Italy;
| | - Mariella Lucente
- Neonatal Intensive Care Unit, Azienda Ospedaliera di Cosenza, 87100 Cosenza, Italy;
| | - Stefano Fiocchi
- Pediatric Department, G. Fornaroli Hospital, 20013 Magenta, Italy;
| | - Irma Capolupo
- Neonatal Intensive Care Unit, Fetal Neonatal and Cardiological Science Research Area, “Bambino Gesù” Children’s Hospital, IRCCS, 00165 Rome, Italy;
| |
Collapse
|
12
|
Steiner K, Sjöberg G, Karsenty C, Bianco L, Bautista-Rodriguez C, Fraisse A. Mind the gap-missing device on the shelf? Retrospective experience with 5/7 Occlutech duct Occluder. Acta Paediatr 2024; 113:812-817. [PMID: 38149770 DOI: 10.1111/apa.17082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/08/2023] [Accepted: 12/08/2023] [Indexed: 12/28/2023]
Abstract
AIM To describe our initial experience with the indications and results of the 5/7 Occlutech® duct Occluder (ODO, Occlutech International AB, Helsingborg, Sweden). A small incremental increase in occluder sizes is of utmost importance for successful outcomes, especially in smaller patients in whom protrusion of the distal disk towards the aorta should be minimised. METHODS Retrospective study of all patients undergoing PDA closure with the 5/7 ODO in three institutions since 2018. RESULTS The 5/7 ODO was used in 18 patients with median age and weight at the time of the procedure of 17.5 months (interquartile range 25th to 75th percentile 8 months- 4.4 years) and 13.6 kg (interquartile range 25th to 75th percentile 6.4-22.5 kg) respectively. All cases were successful. There were no cases of device embolisation, haemolysis, or flow disturbance of the LPA or the aorta. CONCLUSIONS This small retrospective study demonstrated an excellent outcome of transcatheter PDA closure with the 5/7 ODO. The device is a beneficial complement to the existing sizes of PDA devices, filling the gap between the 4/6 and 6/8 ODO and avoiding protrusion of a larger disk in the aortic isthmus.
Collapse
Affiliation(s)
- Kristoffer Steiner
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Gunnar Sjöberg
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Clément Karsenty
- Paediatric and Congenital Cardiology Department, M3C Regional Reference Centre, Toulouse University Hospital, Toulouse, France
| | - Lisa Bianco
- Paediatric Cardiology Services, Royal Brompton Hospital and Harefield NHS Foundation Trust, London, UK
- National Heart and Lung Institute, London, UK
| | - Carles Bautista-Rodriguez
- Paediatric Cardiology Services, Royal Brompton Hospital and Harefield NHS Foundation Trust, London, UK
- National Heart and Lung Institute, London, UK
| | - Alain Fraisse
- Paediatric Cardiology Services, Royal Brompton Hospital and Harefield NHS Foundation Trust, London, UK
- National Heart and Lung Institute, London, UK
| |
Collapse
|
13
|
Surak A, Sidhu A, Ting JY. Should we "eliminate" PDA shunt in preterm infants? A narrative review. Front Pediatr 2024; 12:1257694. [PMID: 38379909 PMCID: PMC10876852 DOI: 10.3389/fped.2024.1257694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 01/24/2024] [Indexed: 02/22/2024] Open
Abstract
The patent ductus arteriosus frequently poses a significant morbidity in preterm infants, subjecting their immature pulmonary vascular bed to substantial volume overload. This, in turn, results in concurrent hypoperfusion to post-ductal organs, and subsequently alters cerebral blood flow. In addition, treatment has not demonstrated definitive improvements in patient outcomes. Currently, the optimal approach remains a subject of considerable debate with ongoing research controversy regarding the best approach. This article provides a comprehensive review of existing literature.
Collapse
Affiliation(s)
- Aimann Surak
- Division of Neonatal-Perinatal Medicine, Department of Pediatrics, University of Alberta, Edmonton, AB, Canada
| | - Amneet Sidhu
- Division of Neonatal-Perinatal Medicine, Department of Pediatrics, McMaster University, Hamilton, ON, Canada
| | - Joseph Y. Ting
- Division of Neonatal-Perinatal Medicine, Department of Pediatrics, University of Alberta, Edmonton, AB, Canada
| |
Collapse
|
14
|
Kikuchi N, Goto T, Katsumata N, Murakami Y, Shinohara T, Maebayashi Y, Sakakibara A, Saito C, Hasebe Y, Hoshiai M, Nemoto A, Naito A. Correlation between the Closure Time of Patent Ductus Arteriosus in Preterm Infants and Long-Term Neurodevelopmental Outcome. J Cardiovasc Dev Dis 2024; 11:26. [PMID: 38248896 PMCID: PMC10816731 DOI: 10.3390/jcdd11010026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 01/09/2024] [Accepted: 01/15/2024] [Indexed: 01/23/2024] Open
Abstract
In patent ductus arteriosus (PDA) in preterm infants, the relationship between treatment timing and long-term developmental prognosis remains unclear. The purpose of this study was to clarify the relationship between the age in days when ductus arteriosus closure occurred and long-term development. Preterm infants with a birth weight of less than 1500 g who were admitted to our NICU over a period of 9 years (2011-2019) and were diagnosed with PDA were included. A new version of the K-type developmental test for corrected ages of 1.5 and 3 years was used as an index of development. The relationship between the duration of PDA and the developmental index was evaluated using Pearson's correlation coefficient, and multiple regression analysis was performed. Development quotient (DQ) at the ages of 1.5 and 3 years showed a correlation with the PDA closure date and the standard deviation (SD) value of the term birth weight. Multiple regression analysis showed a positive correlation of the DQ at 1.5 and 3 years with the SD value of the term birth weight and a negative correlation with the PDA closure date. In addition, a stronger correlation was found in the "posture/motor" sub-item at 3 years. On the other hand, the analysis including preterm infants without PDA showed that preterm infants with PDA closure on the 6th day or later after birth had a significantly lower 3-year-old DQ than preterm infants with a PDA exposure within 5 days. In conclusion, it is suggested that the decrease in cerebral blood flow due to PDA in preterm infants has an adverse effect on long-term neurodevelopment. Appropriate interventions, including surgical treatment for PDA in preterm infants without delay, ideally within 5 days of birth, may be effective in improving the developmental prognosis.
Collapse
Affiliation(s)
- Natsumi Kikuchi
- Department of Neonatology, Perinatal Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan; (N.K.); (N.K.); (Y.M.); (T.S.); (Y.M.); (A.S.); (C.S.); (A.N.); (A.N.)
- Department of Pediatrics, School of Medicine, Yamanashi University, Kofu 409-3821, Japan;
| | - Taichiro Goto
- Lung Cancer and Respiratory Disease Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan
| | - Nobuyuki Katsumata
- Department of Neonatology, Perinatal Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan; (N.K.); (N.K.); (Y.M.); (T.S.); (Y.M.); (A.S.); (C.S.); (A.N.); (A.N.)
| | - Yasushi Murakami
- Department of Neonatology, Perinatal Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan; (N.K.); (N.K.); (Y.M.); (T.S.); (Y.M.); (A.S.); (C.S.); (A.N.); (A.N.)
| | - Tamao Shinohara
- Department of Neonatology, Perinatal Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan; (N.K.); (N.K.); (Y.M.); (T.S.); (Y.M.); (A.S.); (C.S.); (A.N.); (A.N.)
| | - Yuki Maebayashi
- Department of Neonatology, Perinatal Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan; (N.K.); (N.K.); (Y.M.); (T.S.); (Y.M.); (A.S.); (C.S.); (A.N.); (A.N.)
| | - Aiko Sakakibara
- Department of Neonatology, Perinatal Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan; (N.K.); (N.K.); (Y.M.); (T.S.); (Y.M.); (A.S.); (C.S.); (A.N.); (A.N.)
| | - Chisato Saito
- Department of Neonatology, Perinatal Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan; (N.K.); (N.K.); (Y.M.); (T.S.); (Y.M.); (A.S.); (C.S.); (A.N.); (A.N.)
| | - Yohei Hasebe
- Department of Pediatrics, School of Medicine, Yamanashi University, Kofu 409-3821, Japan;
| | - Minako Hoshiai
- Cardiovascular Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan;
| | - Atsushi Nemoto
- Department of Neonatology, Perinatal Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan; (N.K.); (N.K.); (Y.M.); (T.S.); (Y.M.); (A.S.); (C.S.); (A.N.); (A.N.)
| | - Atsushi Naito
- Department of Neonatology, Perinatal Center, Yamanashi Prefectural Central Hospital, Kofu 400-8506, Japan; (N.K.); (N.K.); (Y.M.); (T.S.); (Y.M.); (A.S.); (C.S.); (A.N.); (A.N.)
| |
Collapse
|
15
|
Chan B, Singh Y. Personalized Evidence-Based Management of Patent Ductus Arteriosus in Preterm Infants. J Cardiovasc Dev Dis 2023; 11:7. [PMID: 38248877 PMCID: PMC10816643 DOI: 10.3390/jcdd11010007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/05/2023] [Accepted: 12/20/2023] [Indexed: 01/23/2024] Open
Abstract
There is no universal consensus on management of patent ductus arteriosus (PDA) in preterm infants and it varies significantly worldwide, even among the clinicians within units. The decision to treat requires a thorough understanding of the clinical status of the patient, clinical evaluation of PDA, echocardiographic diagnosis, and hemodynamic impact of ductal shunt on the pulmonary and systemic circulation. In this article, updated evidence on the efficacy and adverse effects of pharmacological treatment options and expectant management are presented, while highlighting the long-term benefits of PDA treatment remains equivocal and controversial. The authors propose a schematic targeted PDA treatment approach based on gestational and chronological age for practical clinical use, and they emphasize important future directions including advancement in PDA device closure techniques, diagnostic echo-parameters, hemodynamic evaluation to assess the impact on other organs, and understanding the long-term outcomes.
Collapse
Affiliation(s)
- Belinda Chan
- Neonatology Division, Department of Pediatrics, University of Utah, Salt Lake City, UT 84113, USA;
- Department of Radiology and Imaging Science, University of Utah, Salt Lake City, UT 84113, USA
| | - Yogen Singh
- Department of Pediatrics, Division of Neonatology, Loma Linda University School of Medicine, Loma Linda, CA 92354, USA
- Department of Pediatrics, Division of Neonatology, University of Southern California (USC), Los Angeles, CA 90007, USA
| |
Collapse
|
16
|
Honnorat M, Perouse-De-Montclos T, Bakloul M, Walton C, Butin M, Vo Van P. Transcatheter closure of patent ductus arteriosus in preterm infants: results from a single-center cohort. Front Pediatr 2023; 11:1292623. [PMID: 38178913 PMCID: PMC10765538 DOI: 10.3389/fped.2023.1292623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 12/07/2023] [Indexed: 01/06/2024] Open
Abstract
Objective To assess the success rate of patent ductus arteriosus (PDA) transcatheter closure in preterm infants and to describe the nature of procedural adverse events and short-term clinical status. Study design All the preterm infants with PDA transcatheter closure were evaluated retrospectively between July 2019 and March 2023 in a single level III neonatal intensive care unit in France. The procedure was performed in the catheterization laboratory using venous canulation. We retrospectively collected data about the patients' characteristics, procedural outcomes and complications. Results Twenty-five infants born between 23.4 and 32.0 weeks of gestational age (mean ± SD 26.3 ± 1.9 weeks) underwent transcatheter PDA closure. Their mean age and weight at the time of the procedure were 52 days (range 22-146 days) and 1,620 g (range 890-3,700 g), respectively. Successful closure was achieved in all but one patient. Procedure related complications were reported in 10 infants (40%), including 6 left pulmonary artery stenosis one of which required a balloon dilatation, two cardiac tamponades and two inferior vena cava thrombosis. Only two post-ligature syndromes occurred after the procedure. Two infants died one of which was related to the procedure. Conclusion Transcatheter closure of a PDA is a valid alternative to surgical ligation due to its high success rate and low incidence of post-ligature syndrome. Nevertheless, we also report rare, although serious complications.
Collapse
Affiliation(s)
- Marion Honnorat
- Service de Réanimation Néonatale, HFME, Hospices Civils de Lyon, Bron, France
| | | | - Mohamed Bakloul
- Service de Cardiologie Pédiatrique, Hôpital Louis Pradel, Hospices Civils de Lyon, Bron, France
| | - Camille Walton
- Cardiologie pédiatrique, Hôpital Privé Natécia, Lyon, France
| | - Marine Butin
- Service de Réanimation Néonatale, HFME, Hospices Civils de Lyon, Bron, France
- INSERM U1111, CNRS UMR 5308, ENS de Lyon, Université Claude Bernard Lyon 1, Centre International de Recherche en Infectiologie, Equipe “Pathogénie des Infections à Staphylocoques”, Lyon, France
| | - Philippe Vo Van
- Service de Réanimation Néonatale, HFME, Hospices Civils de Lyon, Bron, France
| |
Collapse
|
17
|
Lai KC, Richardson T, Berman D, DeMauro SB, King BC, Lagatta J, Lee HC, Lewis T, Noori S, O'Byrne ML, Patel RM, Slaughter JL, Lakshmanan A. Current Trends in Invasive Closure of Patent Ductus Arteriosus in Very Low Birth Weight Infants in United States Children's Hospitals, 2016-2021. J Pediatr 2023; 263:113712. [PMID: 37659587 DOI: 10.1016/j.jpeds.2023.113712] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 08/18/2023] [Accepted: 08/29/2023] [Indexed: 09/04/2023]
Abstract
OBJECTIVE To describe the current practices in invasive patent ductus arteriosus (PDA) closure (surgical ligation or transcatheter occlusion) in very low birth weight (VLBW) infants and changes in patient characteristics and outcomes from 2016 to 2021 among US children's hospitals. STUDY DESIGN We evaluated a retrospective cohort of VLBW infants (birth weight 400-1499 g and gestational age 22-31 weeks) who had invasive PDA closure within 6 months of age from 2016 to 2021 in children's hospitals in the Pediatric Health Information System. Changes in patient characteristics and outcomes over time were evaluated using generalized linear models and generalized linear mixed models. RESULTS 2418 VLBW infants (1182 surgical ligation; 1236 transcatheter occlusion) from 42 hospitals were included. The proportion of infants receiving transcatheter occlusion increased from 17.2% in 2016 to 84.4% in 2021 (P < .001). In 2021, 28/42 (67%) hospitals had performed transcatheter occlusion in > 80% of their VLBW infants needing invasive PDA closure, compared with only 2/42 (5%) in 2016. Although median postmenstrual age (PMA) at PDA closure did not change for the overall cohort, PMA at transcatheter occlusion decreased from 38 weeks in 2016 to 31 weeks by 2020, P < .001. Among those infants not intubated prior to PDA closure, extubation within 3 days postprocedure increased over time (yearly adjusted odds ratios of 1.26 [1.08-1.48]). Length of stay and mortality did not change over time. CONCLUSION We report rapid adoption of transcatheter occlusion for PDA among VLBW infants in US children's hospitals over time. Transcatheter occlusions were performed at younger PMA over time.
Collapse
Affiliation(s)
- Kuan-Chi Lai
- Division of Neonatology, Children's Hospital Los Angeles and University of Southern California, Los Angeles, CA.
| | | | - Darren Berman
- Division of Cardiology, Children's Hospital Los Angeles and University of Southern California, Los Angeles, CA
| | - Sara B DeMauro
- Division of Neonatology, The Children's Hospital of Philadelphia and University of Pennsylvania, Philadelphia, PA
| | - Brian C King
- Division of Newborn Medicine, UPMC Children's Hospital of Pittsburgh and University of Pittsburgh, Pittsburgh, PA
| | - Joanne Lagatta
- Division of Neonatology, Children's Wisconsin and Medical College of Wisconsin, Milwaukee, WI
| | - Henry C Lee
- Division of Neonatology, Rady Children's Hospital and University of California San Diego, San Diego, CA
| | - Tamorah Lewis
- Division of Neonatology, The Hospital for Sick Children and University of Toronto, Toronto, Ontario, Canada
| | - Shahab Noori
- Division of Neonatology, Children's Hospital Los Angeles and University of Southern California, Los Angeles, CA
| | - Michael L O'Byrne
- Division of Cardiology, The Children's Hospital of Philadelphia and University of Pennsylvania, Philadelphia, PA
| | - Ravi M Patel
- Division of Neonatology, Children's Healthcare of Atlanta and Emory University, Atlanta, GA
| | - Jonathan L Slaughter
- Division of Neonatology, Nationwide Children's Hospital and The Ohio State University, Columbus, OH
| | - Ashwini Lakshmanan
- Division of Neonatology, Children's Hospital Los Angeles and University of Southern California, Los Angeles, CA; Department of Health Systems Science, Bernard J. Tyson Kaiser Permanente School of Medicine, Pasadena, CA
| |
Collapse
|
18
|
Baruteau AE, Fraisse A, Butera G, Bautista-Rodriguez C. The Transcatheter Closure of Patent Ductus Arteriosus in Extremely Low-Birth-Weight Infants: Technique and Results. J Cardiovasc Dev Dis 2023; 10:476. [PMID: 38132644 PMCID: PMC10744056 DOI: 10.3390/jcdd10120476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 11/22/2023] [Accepted: 11/24/2023] [Indexed: 12/23/2023] Open
Abstract
Persistent patent ductus arteriosus is a very common condition in preterm infants. Although there is no management agreed by consensus, despite numerous randomized controlled trials, hemodynamically significant patent ductus arteriosus increases morbidity and mortality in these vulnerable patients. Medical treatment is usually offered as first-line therapy, although it carries a limited success rate and potential severe adverse events. In recent years, transcatheter patent ductus arteriosus closure has fast developed and become widely accepted as a safe and efficient alternative to surgical ductal ligation in extremely low birth weight infants >700 g, using most often the dedicated Amplatzer Piccolo Occluder device. This article aims to provide an appraisal of the patients' selection process, and a step-by-step description of the procedure as well as a comprehensive review of its outcomes.
Collapse
Affiliation(s)
- Alban-Elouen Baruteau
- Department of Pediatric Cardiology and Pediatric Cardiac Surgery, CHU Nantes, Nantes Université, FHU PRECICARE, F-44000 Nantes, France
- CIC FEA 1413, INSERM, CHU Nantes, Nantes Université, F-44000 Nantes, France
- L’institut du thorax, INSERM, CNRS, CHU Nantes, Nantes Université, F-44000 Nantes, France
- UMR 1280, PhAN, INRAE, Nantes Université, F-44000 Nantes, France
| | - Alain Fraisse
- Pediatric Cardiology Services, Royal Brompton Hospital, Guy’s & St Thomas’ Foundation Trust, London SW3 6NP, UK; (A.F.); (C.B.-R.)
- National Heart and Lung Institute, Imperial College, London SW7 2BX, UK
| | - Gianfranco Butera
- Cardiology, Cardiac Surgery and Heart Lung Transplantation, ERN GUARD HEART: Bambino Gesù Hospital and Research Institute, IRCCS, 00165 Rome, Italy;
| | - Carles Bautista-Rodriguez
- Pediatric Cardiology Services, Royal Brompton Hospital, Guy’s & St Thomas’ Foundation Trust, London SW3 6NP, UK; (A.F.); (C.B.-R.)
- National Heart and Lung Institute, Imperial College, London SW7 2BX, UK
| |
Collapse
|
19
|
Mumtaz ZA, Sagar P, Sivakumar K, Mohakud AR, Rajendran M, Pavithran S. Risk factors associated with device embolisation or malposition during transcatheter closure of patent ductus arteriosus. Cardiol Young 2023; 33:2041-2048. [PMID: 36515000 DOI: 10.1017/s1047951122003973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Device embolisation is a serious adverse event during transcatheter duct closure. This study analyses risk factors for embolisation. METHODS Demographic parameters, echocardiographic anatomy, haemodynamics, and procedural characteristics of consecutive duct closures in a tertiary centre over 8 years were analysed. Procedures complicated by embolisation were compared to uncomplicated procedures. RESULTS Fifteen embolisations occurred during 376 procedures. All except one embolisation were in infants. The pulmonary artery: aortic pressure ratio was 0.78 ± 0.22. Embolisation was seen significantly more commonly in Type C tubular ducts. Vascular plugs were more significantly associated with embolisations. Logistic regression analysis showed device embolisation was significantly higher in age group of < 6 months compared to 6-12 months (p = 0.02), higher in those with tubular ducts versus conical ducts (p = 0.003), use of vascular plugs compared to conventional duct occluders (p = 0.05), and in duct closure with undersized devices (p = 0.001). There was no in-hospital mortality. Three patients needed surgical retrieval while others were successfully managed in catheterisation laboratory. CONCLUSIONS Device embolisation complicates 4% of transcatheter duct closures, with need for surgery in one-fifth of them. Larger ducts with high pulmonary artery pressures in younger and smaller infants are more often associated with device embolisation. Tubular ducts are more prone for embolisation compared to usual conical ducts. Softer vascular plugs are often associated with embolisations. Intentional device undersizing to avoid vascular obstruction in small patients is a frequent risk factor for embolisation. Precise echocardiographic measurements, correct occluder choice, proper technique and additional care in patients with high pulmonary artery pressures are mandatory to minimise embolisations.
Collapse
Affiliation(s)
- Zeeshan A Mumtaz
- Department of Pediatric Cardiology, Institute of Cardiovascular Diseases, Madras Medical Mission, Chennai, India
| | - Pramod Sagar
- Department of Pediatric Cardiology, Institute of Cardiovascular Diseases, Madras Medical Mission, Chennai, India
| | - Kothandam Sivakumar
- Department of Pediatric Cardiology, Institute of Cardiovascular Diseases, Madras Medical Mission, Chennai, India
| | - Asish R Mohakud
- Department of Pediatric Cardiology, Institute of Cardiovascular Diseases, Madras Medical Mission, Chennai, India
| | - Monica Rajendran
- Department of Pediatric Cardiology, Institute of Cardiovascular Diseases, Madras Medical Mission, Chennai, India
| | - Sreeja Pavithran
- Department of Pediatric Cardiology, Institute of Cardiovascular Diseases, Madras Medical Mission, Chennai, India
| |
Collapse
|
20
|
Bischoff AR, Kennedy KF, Backes CH, Sathanandam S, McNamara PJ. Percutaneous Closure of the Patent Ductus Arteriosus in Infants ≤2 kg: IMPACT Registry Insights. Pediatrics 2023; 152:e2023061460. [PMID: 37529882 DOI: 10.1542/peds.2023-061460] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/03/2023] [Indexed: 08/03/2023] Open
Abstract
OBJECTIVES Percutaneous patent ductus arteriosus (PDA) closure is becoming the standard of care for definitive closure in progressively smaller and younger neonates. The objective of this study was to assess safety and feasibility of percutaneous PDA closure in patients ≤2 kg. METHODS This was a cohort study using the IMPACT Registry (Improving Pediatric and Adult Congenital Treatments) from the American College of Cardiology Foundation's National Cardiovascular Data Registry. Patients who were ≤2 kg at the time of percutaneous PDA closure were included. The primary outcome was the composite of technical failure and/or major adverse event. RESULTS A total of 1587 attempted PDA closures were included, with a 3% incidence of technical failure and 5.5% incidence of the composite outcome. Major adverse events were observed in 3.8% of the patients; the most common events were device embolization requiring retrieval and unplanned cardiac or vascular surgery in 1.3% and 1.3% of cases, respectively. The incidence of the composite outcome was associated with the need for arterial access (P < .001) as well as annual hospital volume of percutaneous PDA closures in infants ≤2 kg (P = .001). The incidence of the composite outcome has decreased overtime, whereas median weight at the time of procedure has also diminished. CONCLUSIONS Percutaneous PDA closure appears to be safe and feasible procedures in infants ≤2 kg. The incidence of major adverse events has continued to decline over the years and seems to have a strong correlation with individual center case volumes and expertise.
Collapse
Affiliation(s)
| | | | - Carl H Backes
- Department of Pediatrics, Nationwide Children's Hospital, Columbus, Ohio
| | - Shyam Sathanandam
- Department of Pediatrics, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Patrick J McNamara
- Department of Pediatrics, Division of Neonatology
- Department of Internal Medicine University of Iowa, Iowa City, Iowa
| |
Collapse
|
21
|
Aw TC, Chan B, Singh Y. Transport and Anaesthesia Consideration for Transcatheter Patent Ductus Arteriosus Closure in Premature Infants. J Cardiovasc Dev Dis 2023; 10:377. [PMID: 37754806 PMCID: PMC10531776 DOI: 10.3390/jcdd10090377] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 08/05/2023] [Accepted: 08/22/2023] [Indexed: 09/28/2023] Open
Abstract
Transcatheter device closure of patent ductus arteriosus (PDA) in preterm infants has been proven to be a feasible and safe technique with promising results when compared to surgical ligation. However, managing transport and anaesthesia in extremely premature infants with haemodynamically significant PDA and limited reserves presents unique challenges. This review article focuses on the key considerations throughout the clinical pathway for the PDA device closure, including referral hospital consultation, patient selection, intra- and inter-hospital transport, and anaesthesia management. The key elements encompass comprehensive patient assessment, meticulous airway management, optimised ventilation strategies, precise thermoregulation, patient-tailored sedation protocols, vigilant haemodynamic monitoring, and safe transport measures throughout the pre-operative, intra-operative, and post-operative phases. A multidisciplinary approach enhances the chances of procedure success, improves patient outcomes, and minimises the risk of complications.
Collapse
Affiliation(s)
- Tuan Chen Aw
- Department of Anaesthesia, Royal Brompton Hospital, London SW3 6NP, UK
| | - Belinda Chan
- Neonatology Division, Department of Pediatrics, University of Utah, Salt Lake City, UT 84108, USA;
- Department of Radiology and Imaging Science, University of Utah, Salt Lake City, UT 84108, USA
| | - Yogen Singh
- Department of Pediatrics, Division of Neonatology, Loma Linda University School of Medicine, Loma Linda, CA 92354, USA;
- Department of Pediatrics, Division of Neonatology, University of Southern California (USC), Los Angeles, CA 92354, USA
| |
Collapse
|
22
|
Meliota G, Vairo U. Transcatheter Interventions for Neonates with Congenital Heart Disease: A Review. Diagnostics (Basel) 2023; 13:2673. [PMID: 37627932 PMCID: PMC10453781 DOI: 10.3390/diagnostics13162673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 06/28/2023] [Accepted: 08/12/2023] [Indexed: 08/27/2023] Open
Abstract
Newborns with congenital heart disease often require interventions linked to high morbidity and mortality rates. In the last few decades, many transcatheter interventions have become the first-line treatments for some critical conditions in the neonatal period. A catheter-based approach provides several advantages in terms of procedural time, length of hospitalization, repeatability and neurodevelopmental issues (usually related to cardiopulmonary bypass). The main transcatheter procedures will be reviewed, as they are now valid alternatives to conventional surgical management.
Collapse
Affiliation(s)
- Giovanni Meliota
- Pediatric Cardiology, Giovanni XXIII Pediatric Hospital, 70126 Bari, Italy;
| | | |
Collapse
|
23
|
Sathanandam S, McNamara P, Pedra C, Toyoshima K, Malekzadeh-Milani S, Patkai J, Baspinar O, Uslu HS, Promphan W, Khorana M, Wang JN, Lin YC, Fujii T, Mainzer G, Salazar-Lizárraga D, Márquez-Gonzalez H, Popat H, Mervis J, Hong NS, Alwi M, Wonwandee R, Schranz D, Stanimir G, Philip R, Ing F. A Global Perspective on PDA Management in the Extremely Premature: Shifting Trend Toward Transcatheter Closure. JOURNAL OF THE SOCIETY FOR CARDIOVASCULAR ANGIOGRAPHY & INTERVENTIONS 2023; 2:100968. [PMID: 39131651 PMCID: PMC11307882 DOI: 10.1016/j.jscai.2023.100968] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/17/2023] [Accepted: 03/20/2023] [Indexed: 08/13/2024]
Abstract
Patent ductus arteriosus (PDA) is a frequently encountered defect in infants born extremely premature (≤26 weeks' gestation). Historically, closure of the PDA was performed using cyclooxygenase inhibitor medications or by surgical ligations. However, the benefits of PDA closure using these therapies have never been demonstrated, albeit studies have previously not focused on the extremely premature infants. Therefore, there was a worldwide trend toward conservative management of the PDA. With improved survival of extremely premature infants, comorbidities associated with the PDA has increased, resulting in finding alternate treatments such as transcatheter patent ductus arteriosus closure (TCPC) for this population. Currently, there is a renewed interest toward selective treatment of the PDA in this high-risk cohort of small infants. This Comprehensive Review article inspects the globally changing trends in the management of the PDA in premature infants, with a special focus on the rising adoption of TCPC. Moreover, this article compiles data from several neonatal networks worldwide to help understand the problem at hand. Understanding the current management of premature infants and their outcomes is fundamentally essential if pediatric cardiologists are to offer TCPC as a viable therapeutic option for this population. This article aims to serve as a guide for pediatric cardiologists on this topic by compiling the results on landmark clinical trials on PDA management and the controversies that arise from these trials. Comparative outcomes from several countries are presented, including interpretations and opinions of the data from experts globally. This is a step toward coming to a global consensus in PDA management in premature infants.
Collapse
Affiliation(s)
- Shyam Sathanandam
- LeBonheur Children’s Hospital, University of Tennessee, Memphis, Tennessee
| | | | - Carlos Pedra
- Instituto Dante Pazzanese de Cardiologia, São Paulo, Brazil
| | | | | | - Juliana Patkai
- Assistance Publique des Hôpitaux de Paris, Paris, France
| | | | - Hasan Sinan Uslu
- Istanbul Şişli Hamidiye Etfal Training and Research Hospital, Istanbul, Turkey
| | - Worakan Promphan
- Queen Sirikit National Institute of Child Health, Bangkok, Thailand
| | - Meera Khorana
- Queen Sirikit National Institute of Child Health, Bangkok, Thailand
| | | | | | | | | | | | | | - Himanshu Popat
- The Children’s Hospital at Westmead and The University of Sydney, Sydney, Australia
| | - Jonathan Mervis
- The Children’s Hospital at Westmead and The University of Sydney, Sydney, Australia
| | - Neoh Siew Hong
- Kuala Lumpur Women’s and Children’s Hospital, Kuala Lumpur, Malaysia
| | - Mazeni Alwi
- Institut Jantung Negara, Kuala Lumpur, Malaysia
| | | | | | | | - Ranjit Philip
- LeBonheur Children’s Hospital, University of Tennessee, Memphis, Tennessee
| | - Frank Ing
- UC Davis Medical Center, Sacramento, California
| |
Collapse
|
24
|
Bruckheimer E, Steiner K, Barak-Corren Y, Slanovic L, Levinzon M, Lowenthal A, Amir G, Dagan T, Birk E. The Amplatzer duct occluder (ADOII) and Piccolo devices for patent ductus arteriosus closure: a large single institution series. Front Cardiovasc Med 2023; 10:1158227. [PMID: 37215550 PMCID: PMC10193946 DOI: 10.3389/fcvm.2023.1158227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 04/10/2023] [Indexed: 05/24/2023] Open
Abstract
Purpose Evaluate Piccolo and ADOII devices for transcatheter patent ductus arteriosus (PDA) closure. Piccolo has smaller retention discs reducing risk of flow disturbance but residual leak and embolization risk may increase. Methods Retrospective review of all patients undergoing PDA closure with an Amplatzer device between January 2008 and April 2022 in our institution. Data from the procedure and 6 months follow-up were collected. Results 762 patients, median age 2.6 years (range 0-46.7) years and median weight 13 kg (range 3.5-92) were referred for PDA closure. Overall, 758 (99.5%) had successful implantation: 296 (38.8%) with ADOII, 418 (54.8%) with Piccolo, and 44 (5.8%) with AVPII. The ADOII patients were smaller than the Piccolo patients (15.8 vs. 20.5 kg, p < 0.001) and with larger PDA diameters (2.3 vs. 1.9 mm, p < 0.001). Mean device diameter was similar for both groups. Closure rate at follow-up was similar for all devices ADOII 295/296 (99.6%), Piccolo 417/418 (99.7%), and AVPII 44/44 (100%). Four intraprocedural embolizations occurred during the study time period: two ADOII and two Piccolo. Following retrieval the PDA was closed with an AVPII in two cases, ADOI in one case and with surgery in the fourth case. Mild stenosis of the left pulmonary artery (LPA) occurred in three patients with ADOII devices (1%) and one patient with Piccolo device (0.2%). Severe LPA stenosis occurred in one patient with ADOII (0.3%) and one with AVPII device (2.2%). Conclusions ADOII and Piccolo are safe and effective for PDA closure with a tendency to less LPA stenosis with Piccolo. There were no cases of aortic coarctation related to a PDA device in this study.
Collapse
Affiliation(s)
- Elchanan Bruckheimer
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Kristoffer Steiner
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Yuval Barak-Corren
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Leonel Slanovic
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Michael Levinzon
- Section of Pediatric Anesthesiology, Schneider Children’s, Medical Center of Israel, Petach Tikva, Israel
| | - Alexander Lowenthal
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Gabriel Amir
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Tamir Dagan
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Einat Birk
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| |
Collapse
|
25
|
Barry OM, Gudausky TM, Balzer DT, Bocks ML, Boe BA, Callahan R, El-Said H, Farias MJ, Foerster S, Goldstein BH, Holzer RJ, Janssen D, Levy P, O'Byrne ML, Rahman G, Sathanandam S, Shahanavaz S, Whiteside W, Turner ME. Safety and Short-Term Outcomes for Infants < 2.5 kg Undergoing PDA Device Closure: A C3PO Registry Study. Pediatr Cardiol 2023:10.1007/s00246-023-03147-4. [PMID: 36995404 DOI: 10.1007/s00246-023-03147-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 03/11/2023] [Indexed: 03/31/2023]
Abstract
To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.
Collapse
Affiliation(s)
- Oliver M Barry
- Division of Pediatric Cardiology, New York-Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-253, New York, NY, 10032, USA.
| | - Todd M Gudausky
- Division of Pediatric Cardiology, Medical College of Wisconsin and Herma Heart Institute at Children's Wisconsin, Milwaukee, WI, USA
| | | | | | - Brian A Boe
- Nationwide Children's Hospital, Columbus, OH, USA
| | | | | | | | - Susan Foerster
- Division of Pediatric Cardiology, Medical College of Wisconsin and Herma Heart Institute at Children's Wisconsin, Milwaukee, WI, USA
| | | | | | - Dana Janssen
- Monroe Carell Jr. Children's Hospital at Vanderbilt, Nashville, TN, USA
| | | | | | | | | | | | | | - Mariel E Turner
- Division of Pediatric Cardiology, New York-Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-253, New York, NY, 10032, USA
| |
Collapse
|
26
|
Guyon P, Duster N, Katheria A, Heyden C, Griffin D, Steinbergs R, Moreno Rojas A, Ratnayaka K, El-Said HG. Institutional Trend in Device Selection for Transcatheter PDA Closure in Premature Infants. Pediatr Cardiol 2022; 43:1716-1722. [PMID: 35430709 PMCID: PMC9587941 DOI: 10.1007/s00246-022-02903-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 03/29/2022] [Indexed: 11/30/2022]
Abstract
We report our experience with transcatheter patent ductus arteriosus (PDA) closure in premature infants and compare patients grouped by the device used for closure: the Microvascular Plug, "MVP" (Medtronic, Minneapolis, MN); Micro Plug Set, "Micro Plug" (KA Medical, Minneapolis, MN); and Amplatzer Piccolo Occluder, "Piccolo" (Abbot, Santa Clara, CA). We also report trends in device selection over time. Studies examining outcomes according to device selection for PDA closure in premature infants are lacking. We performed a retrospective review of all percutaneous PDA closures in premature infants at a single center (June 2018-May 2021). Patients were grouped by initial device selected for PDA closure (intention to treat). Institutional Review Board approval was obtained. 58 premature infants [MVP (n = 25), Micro Plug (n = 25), and Piccolo (n = 8)] underwent successful transcatheter PDA closure (mean gestational age 27 weeks 2 days; mean weight at procedure 1.4 kg; mean age at procedure 28 days). Pre-procedural demographics, procedural data, and follow-up data were similar between groups. There were no significant procedural adverse events. Three devices (2 MVP, 0 Micro Plug, 1 Piccolo p = 0.27) embolized after the procedure. One other device was removed for concern for aortic obstruction. Device selection evolved with a clear trend toward the Micro Plug device over time. Demographic, procedural, and follow-up data were similar between the MVP, Micro Plug, and Piccolo groups. The Micro Plug did not require exchange for suboptimal fitting or embolize and became our preferred device in most cases.
Collapse
Affiliation(s)
- Peter Guyon
- Division of Pediatric Cardiology, Rady Children's Hospital | UC San Diego School of Medicine, 3020 Children's Way MC #5004, San Diego, CA, 92123, USA.
| | - Nicole Duster
- Department of Pediatrics, Rady Children's Hospital | UC San Diego School of Medicine, San Diego, CA, USA
| | - Anup Katheria
- Department of Neonatology, Sharp Mary Birch Hospital for Women and Newborns, San Diego, CA, USA
| | - Caitlyn Heyden
- Division of Pediatric Cardiology, Rady Children's Hospital | UC San Diego School of Medicine, 3020 Children's Way MC #5004, San Diego, CA, 92123, USA
| | - Danica Griffin
- Division of Pediatric Cardiology, Rady Children's Hospital | UC San Diego School of Medicine, 3020 Children's Way MC #5004, San Diego, CA, 92123, USA
| | - Ronald Steinbergs
- Division of Pediatric Cardiology, Rady Children's Hospital | UC San Diego School of Medicine, 3020 Children's Way MC #5004, San Diego, CA, 92123, USA
| | - Andres Moreno Rojas
- Division of Pediatric Cardiology, Rady Children's Hospital | UC San Diego School of Medicine, 3020 Children's Way MC #5004, San Diego, CA, 92123, USA
| | - Kanishka Ratnayaka
- Division of Pediatric Cardiology, Rady Children's Hospital | UC San Diego School of Medicine, 3020 Children's Way MC #5004, San Diego, CA, 92123, USA
| | - Howaida G El-Said
- Division of Pediatric Cardiology, Rady Children's Hospital | UC San Diego School of Medicine, 3020 Children's Way MC #5004, San Diego, CA, 92123, USA
| |
Collapse
|
27
|
Van Pelt E, Reo R, Lovelace C, Eshelman A, Beckman B, Chisolm J, Boe B, Backes C, Cua CL. Utility of Follow-Up Echocardiograms in Uncomplicated PDA Device Closures Performed During Infancy. Cardiol Ther 2022; 11:523-530. [PMID: 36074260 PMCID: PMC9652175 DOI: 10.1007/s40119-022-00278-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 08/23/2022] [Indexed: 11/27/2022] Open
Abstract
INTRODUCTION Guidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure during infancy. METHODS Chart review was performed on patients who had a PDA closure at not more than 1 year of age between January 1, 2002 and June 1, 2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE at least 3 months after procedure, or had a velocity greater than 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE at least 3 months after device placement. Time points included the first TTE after the procedure, first TTE at least 3 months after procedure, and the most recent TTE. RESULTS Total of 147 infants met the inclusion criteria. Age and weight at initial procedure were 141 ± 217 days and 4.2 ± 2.8 kg. There was no significant difference in DAo velocity between initial and most recent TTE. LPA velocity and left ventricular diastolic Z score significantly decreased between initial and most recent TTE. Seventy-eight patients had repeat echocardiograms more than 1 year after PDA procedure with no change in clinical management. No patient underwent an intervention on the LPA or DAo for stenosis. CONCLUSION In patients who underwent an uncomplicated PDA closure during infancy, TTE parameters either stayed stable or improved over time. These findings need to be corroborated in larger studies with longer follow-up. If verified, the long-term TTE guidelines may need to be simplified for this patient population.
Collapse
Affiliation(s)
- Erin Van Pelt
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Rachel Reo
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Casey Lovelace
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Anne Eshelman
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Brian Beckman
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Joanne Chisolm
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Brian Boe
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Carl Backes
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Clifford L Cua
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA.
| |
Collapse
|
28
|
Paediatrician's guide to post-operative care for biventricular CHD: a review. Cardiol Young 2022; 32:1721-1727. [PMID: 36165406 DOI: 10.1017/s1047951122002955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
IMPORTANCE Paediatricians play an integral role in the lifelong care of children with CHD, many of whom will undergo cardiac surgery. There is a paucity of literature for the paediatrician regarding the post-operative care of such patients. OBSERVATIONS The aim of this manuscript is to summarise essential principles and pertinent lesion-specific context for the care of patients who have undergone surgery or intervention resulting in a biventricular circulation. CONCLUSIONS AND RELEVANCE Familiarity with common issues following cardiac surgery or intervention, as well as key details regarding specific lesions and surgeries, will aid the paediatrician in providing optimal care for these patients.
Collapse
|
29
|
Herron C, Forbes TJ, Kobayashi D. Renal Function After Transcatheter Piccolo Patent Ductus Arteriosus Closure With Contrast Angiography in Extremely Premature Infants. Am J Cardiol 2022; 181:113-117. [PMID: 35970628 DOI: 10.1016/j.amjcard.2022.07.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 06/28/2022] [Accepted: 07/05/2022] [Indexed: 11/24/2022]
Abstract
Transcatheter patent ductus arteriosus (PDA) device closure is increasingly performed in extremely premature infants. Contrast angiography improves the procedural safety and effectiveness by precise anatomic delineation. Contrast nephropathy is a concern in clinically ill premature infants, especially with the presence of renal insufficiency. We hypothesized that the benefit of transcatheter PDA closure outweighs the harm of contrast nephropathy in extremely premature infants. A total of 160 infants underwent successful transcatheter (n = 59) and surgical (n = 101) PDA closure at a median age of 26 (7 to 78) days. The surgical group had a lower procedural weight (870 vs 960 g, p = 0.014). In the transcatheter group, serum creatinine decreased from 0.48 to 0.45 mg/100 ml at 24 hours (p = 0.003, n = 59) and decreased further to 0.37 mg/100 ml at 5 to 7 days after closure (p <0.001). Median contrast amount was 1.9 ml/kg (0.6 to 6.1). In 8 infants with pre-existing renal insufficiency who underwent transcatheter closure, serum creatine significantly improved from 1.44 to 1.36 mg/100 ml at 24 hours and 0.79 mg/100 ml at 5 to 7 days after closure (p <0.001). There was no difference in improvement of serum creatinine between transcatheter and surgical closure groups. In conclusion, despite the use of contrast, serum creatinine significantly improved with transcatheter PDA closure even in infants with pre-existing renal insufficiency. Contrast angiography should not be discouraged for transcatheter PDA closure because of the concern for contrast nephropathy in extremely premature infants.
Collapse
Affiliation(s)
- Christopher Herron
- Division of Cardiology, Children's Hospital of Michigan, Detroit, Michigan; Department of Pediatrics, Central Michigan University College of Medicine, Mount Pleasant, Michigan
| | - Thomas J Forbes
- Division of Cardiology, Children's Hospital of Michigan, Detroit, Michigan; Department of Pediatrics, Central Michigan University College of Medicine, Mount Pleasant, Michigan
| | - Daisuke Kobayashi
- Division of Cardiology, Children's Hospital of Michigan, Detroit, Michigan; Department of Pediatrics, Central Michigan University College of Medicine, Mount Pleasant, Michigan.
| |
Collapse
|
30
|
Abstract
We present the case of a 4-month-old, former 23-week premature baby who underwent patent ductus arteriosus device closure in the cardiac catheterisation lab with an Amplatzer Piccolo™ device at 12 weeks of life. This was complicated by late migration of the device into the aorta resulting in severe obstruction and requiring surgical intervention.
Collapse
|
31
|
Reo R, Van Pelt E, Lovelace C, Eshelman A, Beckman B, Chisolm J, Boe B, Backes C, Cua CL. Utility of Follow-Up Echocardiograms in Uncomplicated PDA Device Closures Performed After Infancy. Cardiol Ther 2022; 11:445-452. [PMID: 35780440 PMCID: PMC9381662 DOI: 10.1007/s40119-022-00272-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 06/14/2022] [Indexed: 11/25/2022] Open
Abstract
Introduction Guidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure after infancy. Methods Chart review was performed on patients who had a PDA closure ≥ 1 year of age between 1/1/2002 and 6/1/2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE ≥ 6 months after procedure, had a residual PDA or velocity > 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE ≥ 6 months after device placement. Time points included the initial TTE after the procedure, first TTE ≥ 6 months after procedure, and the most recent TTE. Results A total of 189 patients met the study criteria. The median age and weight at initial procedure were 2.7 (1.0–64.7) years and 12.5 (3.4–69.2) kg. Most recent TTE was performed 2.0 (0.4–17.0) years after PDA closure. There were no significant differences in fractional shortening (36.4 ± 5.0% vs. 36.9 ± 5.6%) or LPA velocity (1.1 ± 0.4 m/s vs. 1.1 ± 0.4 m/s) from initial to most recent TTE, respectively. Left ventricular internal diastolic diameter Z-score significantly decreased (1.4 ± 1.8 vs. − 0.01 ± 1.2, p < 0.01) and DAo peak velocity significantly increased (1.2 ± 0.3 m/s vs. 1.3 ± 0.3 m/s, p = 0.02) from initial to most recent TTE, respectively. No patient died or underwent an intervention on the LPA or DAo for stenosis. Seventy-five patients had a total of 208 repeat TTE > 1 year after PDA procedure with no change in clinical management. Conclusions In patients who underwent an uncomplicated PDA closure after infancy, TTE parameters improved or stayed within normal limits on the most recent TTE. Repeat lifetime TTEs after 1-year post-device placement in this population may not necessarily be needed if there are no clinical concerns.
Collapse
Affiliation(s)
- Rachel Reo
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Erin Van Pelt
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Casey Lovelace
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Anne Eshelman
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Brian Beckman
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Joanne Chisolm
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Brian Boe
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Carl Backes
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Clifford L Cua
- Heart Center, Nationwide Children's Hospital, Columbus, OH, USA.
| |
Collapse
|
32
|
Barry OM, Bouhout I, Turner ME, Petit CJ, Kalfa DM. Transcatheter Cardiac Interventions in the Newborn: JACC Focus Seminar. J Am Coll Cardiol 2022; 79:2270-2283. [PMID: 35654498 DOI: 10.1016/j.jacc.2022.03.374] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 03/21/2022] [Accepted: 03/30/2022] [Indexed: 11/25/2022]
Abstract
For neonates with critical congenital heart disease requiring intervention, transcatheter approaches for many conditions have been established over the past decades. These interventions may serve to stabilize or palliate to surgical next steps or effectively primarily treat the condition. Many transcatheter interventions have evidence-based records of effectiveness and safety, which have led to widespread acceptance as first-line therapies. Other techniques continue to innovatively push the envelope and challenge the optimal strategies for high-risk neonates with right ventricular outflow tract obstruction or ductal-dependent pulmonary blood flow. In this review, the most commonly performed neonatal transcatheter interventions will be described to illustrate the current state of the field and highlight areas of future opportunity.
Collapse
Affiliation(s)
- Oliver M Barry
- Division of Pediatric Cardiology, NewYork-Presbyterian-Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, New York, USA
| | - Ismail Bouhout
- Section of Pediatric and Congenital Cardiac Surgery, Division of Cardiac, Thoracic and Vascular Surgery, NewYork-Presbyterian-Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, New York, USA
| | - Mariel E Turner
- Division of Pediatric Cardiology, NewYork-Presbyterian-Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, New York, USA
| | - Christopher J Petit
- Division of Pediatric Cardiology, NewYork-Presbyterian-Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, New York, USA.
| | - David M Kalfa
- Section of Pediatric and Congenital Cardiac Surgery, Division of Cardiac, Thoracic and Vascular Surgery, NewYork-Presbyterian-Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, New York, USA.
| |
Collapse
|
33
|
Leshen MA, Devanagondi R, Saul D, Chaturvedi A. Physiological fetal vascular shunts and failure to regress: what the radiologist needs to know. Pediatr Radiol 2022; 52:1207-1223. [PMID: 35166890 DOI: 10.1007/s00247-022-05302-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 09/13/2021] [Accepted: 01/27/2022] [Indexed: 10/19/2022]
Abstract
The fetal circulation is characterized by the presence of three physiological vascular shunts - the ductus arteriosus, the foramen ovale and the ductus venosus. Acting in concert, these shunts preferentially stream blood flow in a pattern that maximizes efficiency of blood oxygenation by the maternofetal unit. Shortly following the transition to extrauterine life, a quick and predetermined succession of events results in closure of these embryological structures with consequent establishment of postnatal vascular flow patterns. While this transition is often seamless, the physiological shunts of the fetus occasionally fail to regress. Such failure to regress can occur in isolation or in association with other congenital malformations. This failed regression challenges the circulatory physiology of the neonate and might have implications for the optimum functioning of several organ systems. When symptomatic, these shunts are treated. Interventions, when undertaken, might be medical, endovascular or surgical. The radiologist's role continues to expand in the assessment of these shunts, in providing a roadmap for treatment and in prompt identification of treatment-related complications. This review is to familiarize radiologists with the embryology, pre- and post-treatment imaging appearances, and associated complications of persistent fetal vascular shunts.
Collapse
Affiliation(s)
- Michael A Leshen
- Department of Imaging Sciences, University of Rochester Medical Center, 601 Elmwood Ave., Rochester, NY, 14642, USA.
| | - Rajiv Devanagondi
- Division of Pediatric Cardiology, Department of Pediatrics, University of Rochester Medical Center, Rochester, NY, USA
| | - David Saul
- Department of Medical Imaging, A. I. DuPont Hospital for Children, Wilmington, DE, USA
| | - Apeksha Chaturvedi
- Pediatric Imaging Section, Department of Imaging Sciences, Golisano Children's Hospital, University of Rochester Medical Center, Rochester, NY, USA
| |
Collapse
|
34
|
Is early patent ductus arteriosus ligation helpful in premature neonates? A 10-year retrospective study. World J Pediatr 2022; 18:350-357. [PMID: 35254623 DOI: 10.1007/s12519-022-00527-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Accepted: 02/13/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND To compare short and long outcomes between early (≤ 28 days) (EL) and late ligation (LL) groups. To explore factors predicting early extubation (≤ 7 days) after patent ductus arteriosus (PDA) ligation. METHODS We conducted a single center, retrospective cohort study of preterm infants < 32 weeks who underwent surgical ligation over a 10-year period (2009-2019). RESULTS A total of 133 infants underwent PDA ligation, in the study period. Both groups had similar short-term outcome such as bronchopulmonary dysplasia (BPD) or death (96% vs. 98%, P = 0.64) and long-term clinical outcomes including Bayley's assessment at 2 years corrected age. Fewer infants in the EL group developed severe BPD (63% vs. 81%, P = 0.02). Age at ligation had adjusted odds ratio of 1.04 with over lapping confidence interval (95% CI 1.0-1.1, P = 0.02) for severe BPD/death. There was no difference in day of extubation between the EL and LL group (8 days vs. 7 days, P = 0.85). Left atrium/aortic root ratio of ≥ 1.75 would give sensitivity of 41% and 80% specificity for early extubation (area under the curve of 0.61). There was marginal reduction of hospital stay in the EL group [113 (105-121) days vs. 115 (107-123) days; log rank P = 0.026]. CONCLUSION EL can be delivered safely with a clinically important lower incidence of severe BPD and shorter duration of hospital stay compared to LL.
Collapse
|
35
|
Phenotyping respiratory decompensation following definitive closure of the patent ductus arteriosus in preterm infants. J Perinatol 2022; 42:649-654. [PMID: 34650199 DOI: 10.1038/s41372-021-01226-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 07/27/2021] [Accepted: 08/20/2021] [Indexed: 11/09/2022]
Abstract
OBJECTIVE To identify risk factors associated with high-frequency ventilation (HFV) following definitive closure of the patent ductus arteriosus (PDA). METHODS We performed a retrospective study of premature infants (<37 weeks) who were mechanically ventilated before and after surgical or transcatheter PDA closure. Primary outcome was HFV requirement within 24 h of procedure. Logistic regression was used to estimate clinical associations with post procedure HFV requirement. RESULTS We identified 110 infants who were mechanically ventilated before PDA closure, of which 48 (44%) escalated to HFV within 24 h after closure. In the multivariable model, surgical ligation (OR 21.5, 95% CI 1.6-284), elevated Respiratory Severity Score (RSS) 1 h post-procedure (OR 1.78, 95% CI 1.07-2.99) and 12 h post-procedure (OR 2.12, 95% CI 1.37-3.26) were independent predictors of HFV. CONCLUSION Surgical ligation and elevated RSS values over the first 12 h after PDA closure are risk factors for HFV.
Collapse
|
36
|
Salam A, Bautista-Rodriguez C, Karsenty C, Bouvaist H, Piccinelli E, Fraisse A. Transcatheter closure of tubular patent ductus arteriosus using muscular ventricular septal defect devices in infants and small children with congestive heart failure. Arch Cardiovasc Dis 2022; 115:134-141. [DOI: 10.1016/j.acvd.2022.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 01/12/2022] [Accepted: 01/13/2022] [Indexed: 11/29/2022]
|
37
|
Nasef MA, Sullivan DO, Ng LY, Walsh KP, Oslizlok P, McCrossan B, Kenny D, Sathanandam S. Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg. Catheter Cardiovasc Interv 2022; 99:1545-1550. [PMID: 35094486 PMCID: PMC9543682 DOI: 10.1002/ccd.30105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 01/05/2022] [Accepted: 01/13/2022] [Indexed: 12/03/2022]
Abstract
Background The sole Food and Drug Administration‐approved device for transcatheter closure of the patent arterial duct in premature infants is indicated for patent ductus arteriosus (PDAs) ≤ 4 mm in diameter. We report a two‐center experience with transcatheter closure of large PDAs (>4 mm) in infants weighing <2.5 kg using the Microvascular Plug 7Q (MVP‐7Q) device. Methods This is a retrospective review of departmental databases and medical charts to define patient cohort and report demographic, procedural, and follow‐up data. Results Twenty‐two patients (12 male) with a median gestational age and birthweight of 25.5 weeks (interquartile range [IQR] = 24–28) and 800 g (572–1075), respectively, underwent attempted PDA occlusion with the MVP‐7Q using a transvenous approach. The median age and weight at the time of PDA occlusion was 32 days (IQR = 24–28) and 1100 g (IQR = 960–1700), respectively. The median PDA length was 12 mm (IQR = 11–12.65). The median PDA diameters at the aortic and pulmonary ends were 5.1 (IQR = 4.9–5.5) and 4.8 mm (IQR = 4.6–5.3), respectively. Successful device occlusion was achieved in 20 patients (91%). There were two failed attempts: One due to inappropriate sizing, and the other secondary to left pulmonary artery stenosis. There were no procedural complications and no residual shunting on follow‐up. Conclusions The MVP‐7Q is safe and effective for transcatheter closure of large (>4 mm) PDAs in infants <2.5 kg. The lack of retention disks may help with avoiding impingement on surrounding vessels.
Collapse
Affiliation(s)
- Mohamed Al Nasef
- Department of Paediatric Cardiology Children's Health Ireland at Crumlin Dublin Ireland
| | - Donnchadh O. Sullivan
- Department of Paediatric Cardiology Children's Health Ireland at Crumlin Dublin Ireland
| | - Li Yen Ng
- Department of Paediatric Cardiology Children's Health Ireland at Crumlin Dublin Ireland
| | - Kevin P. Walsh
- Department of Paediatric Cardiology Children's Health Ireland at Crumlin Dublin Ireland
| | - Paul Oslizlok
- Department of Paediatric Cardiology Children's Health Ireland at Crumlin Dublin Ireland
| | - Brian McCrossan
- Department of Paediatric Cardiology Children's Health Ireland at Crumlin Dublin Ireland
| | - Damien Kenny
- Department of Paediatric Cardiology Children's Health Ireland at Crumlin Dublin Ireland
| | - Shyam Sathanandam
- Department of Pediatric Cardiology Le Bonheur Children's Hospital, Memphis Tennessee USA
| |
Collapse
|
38
|
Wu W, Chen H, Chen T. Evaluation of Cardiac Function Characteristics after Patent Ductus Arteriosus Closure in Children and Adults by Echocardiographic Data. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:1310841. [PMID: 35126616 PMCID: PMC8816572 DOI: 10.1155/2022/1310841] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/19/2021] [Accepted: 12/31/2021] [Indexed: 11/17/2022]
Abstract
This study was to investigate the value of echocardiographic data in assessing changes in cardiac function before and after transcatheter closure in children and adult patients with patent ductus arteriosus (PDA). In this study, 150 patients with isolated PDA treated by cardiac catheterization and transcatheter closure were selected as the study sample. Real-time color Doppler echocardiography was used both after and after operation. The results showed that the left ventricle returned to normal in 75 patients one day after operation, with an average age of 10.95 ± 3.27 years; the left ventricle did not return to normal in 10 patients 360 days after operation, with an average age of 64.31 ± 7.05 years. Left ventricular end diastolic volume index (LVEDVI) and left ventricular end systolic volume index (LVESVI) of patients decreased significantly one day after operation and remained at 51.95 ± 9.55 mL/m2 and 20.36 ± 8.11 mL/m-2, respectively. In summary, echocardiographic data have a high reference value in assessing cardiac function characteristics in children and adult patients with PDA and are worthy of further promotion.
Collapse
Affiliation(s)
- Wenhai Wu
- Cardiac Color Doppler Ultrasound Room, Quanzhou First Hospital Affiliated to Fujian Medical University, Quanzhou, 362000 Fujian, China
| | - Hongwei Chen
- Cardiac Surgery, Quanzhou First Hospital Affiliated to Fujian Medical University, Quanzhou, 362000 Fujian, China
| | - Tianbao Chen
- Department of Internal Medicine-Cardiovascular, Quanzhou First Hospital Affiliated to Fujian Medical University, Quanzhou, 362000 Fujian, China
| |
Collapse
|
39
|
Ishida S, Yamaguchi A, Ooka M, Kenmochi M, Nakanishi H. Evaluation of postoperative complications for patent ductus arteriosus in extremely-low-birthweight infants. Pediatr Int 2022; 64:e14759. [PMID: 33930217 DOI: 10.1111/ped.14759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 04/06/2021] [Accepted: 04/16/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND Patent ductus arteriosus (PDA), which disrupts the hemodynamics early after birth, causes intraventricular hemorrhage and neonatal necrotizing. Unlike medical treatment for hemodynamically significant PDA, there are institutional disparities in the criteria for surgical treatment METHODS: We aimed to clarify the postoperative indications of surgery for hemodynamically significant PDA and the postoperative complications associated with surgery. RESULTS Thirty-six extremely-low-birthweight infants (median gestational age 25.2 weeks, median birthweight 699 g) required video-assisted thoracoscopic surgery for PDA (VATS-PDA). The treatment indication of VATS-PDA was resistance to medical treatment in 17 cases, relapsed PDA in 15 cases, and no additional administration of indomethacin because of severe side effects in four cases. Complications with VATS-PDA occurred in eight of 36 cases. There were three cases of pneumothorax, two of thoracotomy transition, two of pulmonary hemorrhage, and four of post-ligation cardiac syndrome (PLCS). VATS-PDA-related death occurred in two cases due to PLCS. The frequency of four or more administrations of indomethacin, with or without postoperative complications, was 88% vs. 39%, respectively (P = 0.04). CONCLUSIONS All postoperative deaths were caused by PLCS, which had the highest risk of poor prognosis. VATS-PDA should be considered for unclosed PDA after one course of indomethacin administration.
Collapse
Affiliation(s)
- Shuji Ishida
- Department of Pediatrics, Kitasato University Hospital, Kanagawa, Japan
| | - Ayano Yamaguchi
- Department of Pediatrics, Kitasato University Hospital, Kanagawa, Japan
| | - Mari Ooka
- Department of Pediatrics, Kitasato University Hospital, Kanagawa, Japan
| | - Manabu Kenmochi
- Department of Pediatrics, Kitasato University Hospital, Kanagawa, Japan
| | - Hidehiko Nakanishi
- Department of Pediatrics, Kitasato University Hospital, Kanagawa, Japan.,Division of Neonatal Intensive Care Medicine, Research and Development Center for New Medical Frontiers, Kitasato University School of Medicine, Kanagawa, Japan
| |
Collapse
|
40
|
Kuntz MT, Staffa SJ, Graham D, Faraoni D, Levy P, DiNardo J, Maschietto N, Nasr VG. Trend and Outcomes for Surgical Versus Transcatheter Patent Ductus Arteriosus Closure in Neonates and Infants at US Children's Hospitals. J Am Heart Assoc 2021; 11:e022776. [PMID: 34970919 PMCID: PMC9075185 DOI: 10.1161/jaha.121.022776] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Pharmacologic therapy for patent ductus arteriosus closure is not consistently successful. Surgical ligation (SL) or transcatheter closure (TC) may be needed. Large multicenter analyses comparing outcomes and resource use between SL and TC are lacking. We hypothesized that patients undergoing TC have improved outcomes compared with SL, including mortality, hospital and intensive care unit length of stay, and mechanical ventilation. Methods and Results Using the 2016 to 2020 Pediatric Health Information System database, characteristics, outcomes, and charges of patients aged <1 year who underwent TC or SL were analyzed. A total of 678 inpatients undergoing TC (n=503) or SL (n=175) were identified. Surgical patients were younger (0.1 versus 0.53 years; P<0.001) and more premature (60% versus 20.3%; P<0.001). Surgical patients had higher mortality (1.7% versus 0%; P=0.02). Using inverse probability of treatment weighting by the propensity score, multivariable-adjusted analyses demonstrated favorable outcomes in TC: intensive care unit admission rates (adjusted odds ratio [OR], 0.2; 95% CI, 0.11-0.32; P<0.001); mechanical ventilation rates (adjusted OR, 0.3; 95% CI, 0.19-0.56; P<0.001); and shorter hospital (adjusted coefficient, 2 days shorter; 95% CI, 1.3-2.7; P<0.001) and postoperative (adjusted coefficient, 1.2 days shorter; 95% CI, 0.1-2.3; P=0.039) stays. Overall charges and readmission rates were similar. Among premature neonates and infants, hospital (adjusted difference in medians, 4 days; 95% CI, 1.7-6.3 days; P<0.001) and postoperative stays (adjusted difference in medians, 3 days; 95% CI, 1.1-4.9 days; P=0.002) were longer for SL. Conclusions TC is associated with lower mortality and reduced length of stay compared with SL. Rates of TC continue to increase compared with SL.
Collapse
Affiliation(s)
- Michael T Kuntz
- Department of Anesthesiology Critical Care and Pain Medicine Boston Children's HospitalHarvard Medical School Boston MA.,Division of Pediatric Cardiac Anesthesiology Department of Anesthesiology Monroe Carell Jr. Children's Hospital at Vanderbilt Nashville TN
| | - Steven J Staffa
- Department of Anesthesiology Critical Care and Pain Medicine Boston Children's HospitalHarvard Medical School Boston MA
| | - Dionne Graham
- Department of Pediatrics Boston Children's HospitalHarvard Medical School Boston MA
| | - David Faraoni
- Arthur S. Keats Division of Pediatric Cardiovascular Anesthesia Department of Anesthesiology, Perioperative and Pain Medicine Texas Children's HospitalBaylor College of Medicine Houston TX
| | - Philip Levy
- Division of Newborn Medicine Department of Pediatrics Boston Children's HospitalHarvard Medical School Boston MA
| | - James DiNardo
- Department of Anesthesiology Critical Care and Pain Medicine Boston Children's HospitalHarvard Medical School Boston MA
| | - Nicola Maschietto
- Department of Cardiology Boston Children's HospitalHarvard Medical School Boston MA
| | - Viviane G Nasr
- Department of Anesthesiology Critical Care and Pain Medicine Boston Children's HospitalHarvard Medical School Boston MA
| |
Collapse
|
41
|
Méot M, Haddad RN, Patkai J, Abu Zahira I, Di Marzio A, Szezepanski I, Bajolle F, Kermorvant E, Lapillonne A, Bonnet D, Malekzadeh-Milani S. Spontaneous Closure of the Arterial Duct after Transcatheter Closure Attempt in Preterm Infants. CHILDREN (BASEL, SWITZERLAND) 2021; 8:children8121138. [PMID: 34943334 PMCID: PMC8700662 DOI: 10.3390/children8121138] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 11/13/2021] [Accepted: 11/24/2021] [Indexed: 11/16/2022]
Abstract
(1) Background: Transcatheter closure of the patent arterial duct (TCPDA) in preterm infants is an emerging procedure. Patent arterial duct (PDA) spontaneous closure after failed TCPDA attempts is seen but reasons and outcomes are not reported; (2) Methods: We retrospectively included all premature infants <2 kg with abandoned TCPDA procedures from our institutional database between September 2017 and August 2021. Patients’ data and outcomes were reviewed; (3) Results: The procedure was aborted in 14/130 patients referred for TCPDA. Two patients had spasmed PDA upon arrival in the catheterization laboratory and had no intervention. One patient had ductal spasm after guidewire cross. Four patients had unsuitable PDA size/shape for closure. In seven patients, device closure was not possible without causing obstruction on adjacent vessels. Among the 12 patients with attempted TCPDA, five had surgery on a median of 3 days after TCPDA and seven had a spontaneous PDA closure within a median of 3 days after the procedure. Only the shape of the PDA differed between the surgical ligation group (short and conical) and spontaneous closure group (F-type); (4) Conclusions: In the case of TCPDA failure, mechanically induced spontaneous closure may occur early after the procedure. Surgical ligation should be postponed when clinically tolerated.
Collapse
Affiliation(s)
- Mathilde Méot
- Centre de Référence Malformations Cardiaques Congénitales Complexes—M3C, Hôpital Necker-Enfants Malades, 75015 Paris, France; (R.N.H.); (I.A.Z.); (I.S.); (F.B.); (D.B.); (S.M.-M.)
- Correspondence: ; Tel.: +33-144494357
| | - Raymond N. Haddad
- Centre de Référence Malformations Cardiaques Congénitales Complexes—M3C, Hôpital Necker-Enfants Malades, 75015 Paris, France; (R.N.H.); (I.A.Z.); (I.S.); (F.B.); (D.B.); (S.M.-M.)
| | - Juliana Patkai
- Neonatology Department, Port-Royal Hospital, 75014 Paris, France;
| | - Ibrahim Abu Zahira
- Centre de Référence Malformations Cardiaques Congénitales Complexes—M3C, Hôpital Necker-Enfants Malades, 75015 Paris, France; (R.N.H.); (I.A.Z.); (I.S.); (F.B.); (D.B.); (S.M.-M.)
| | - Anna Di Marzio
- Anesthesiology, Hôpital Necker-Enfants Malades, 75015 Paris, France;
| | - Isabelle Szezepanski
- Centre de Référence Malformations Cardiaques Congénitales Complexes—M3C, Hôpital Necker-Enfants Malades, 75015 Paris, France; (R.N.H.); (I.A.Z.); (I.S.); (F.B.); (D.B.); (S.M.-M.)
| | - Fanny Bajolle
- Centre de Référence Malformations Cardiaques Congénitales Complexes—M3C, Hôpital Necker-Enfants Malades, 75015 Paris, France; (R.N.H.); (I.A.Z.); (I.S.); (F.B.); (D.B.); (S.M.-M.)
| | - Elsa Kermorvant
- Neonatology Department, Hôpital Necker-Enfants Malades, 75015 Paris, France; (E.K.); (A.L.)
- UFR de Médecine, Université de Paris, Site Cordeliers, 75006 Paris, France
| | - Alexandre Lapillonne
- Neonatology Department, Hôpital Necker-Enfants Malades, 75015 Paris, France; (E.K.); (A.L.)
- UFR de Médecine, Université de Paris, Site Cordeliers, 75006 Paris, France
| | - Damien Bonnet
- Centre de Référence Malformations Cardiaques Congénitales Complexes—M3C, Hôpital Necker-Enfants Malades, 75015 Paris, France; (R.N.H.); (I.A.Z.); (I.S.); (F.B.); (D.B.); (S.M.-M.)
- UFR de Médecine, Université de Paris, Site Cordeliers, 75006 Paris, France
| | - Sophie Malekzadeh-Milani
- Centre de Référence Malformations Cardiaques Congénitales Complexes—M3C, Hôpital Necker-Enfants Malades, 75015 Paris, France; (R.N.H.); (I.A.Z.); (I.S.); (F.B.); (D.B.); (S.M.-M.)
| |
Collapse
|
42
|
Meot M, Gaudin R, Szezepanski I, Bajolle F, Bonnet D, Malekzadeh-Milani S. Transcatheter patent arterial duct closure in premature infants: A new technique to ease access to the patent arterial duct, with particular benefit for the tricuspid valve. Arch Cardiovasc Dis 2021; 114:482-489. [PMID: 34312100 DOI: 10.1016/j.acvd.2021.06.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 02/08/2021] [Accepted: 06/01/2021] [Indexed: 01/31/2023]
Abstract
BACKGROUND Transcatheter patent arterial duct (PAD) closure in premature infants has been shown to be feasible. Since our early transcatheter PAD closure procedures in premature infants at Hôpital Necker Enfants Malades, we have changed our technique several times to advance the guidewire through the right heart to avoid tricuspid valve damage. AIM To describe the technique we have been using since May 2019, to report our results with a particular focus on tricuspid leaks and to analyse the potential mechanisms of tricuspid lesion development with previous methods. METHODS All premature infants weighing<2kg who underwent transcatheter PAD closure with this new technique were included. Demographic data, procedural data, outcome and procedural complications were reviewed, with particular attention to the occurrence of tricuspid regurgitation. RESULTS Between May 2019 and May 2020, 33 patients were included. Median gestational age was 25 weeks. Median birth weight and procedural weight were 690g (range 490-1065g; interquartile range [IQR] 620-785g) and 1160g (range 900-1900g; IQR 1030-1300g), respectively. Median age at procedure was 35 (IQR 30-46) days. PAD anatomy was evaluated on transthoracic echocardiography only. The median duct diameter was 3 (IQR 2.5-3.2) mm at the pulmonary end. Success rate was 100% (defined as successful closure without residual shunt). One patient had a renal vein thrombosis, which fully resolved with low-molecular-weight heparin anticoagulation. No tricuspid regurgitation or stenosis of the left pulmonary artery or the aorta was seen. One patient died of a superior caval vein obstruction with bilateral chylothorax related to a central catheter thrombosis 56 days after the procedure, unrelated to the catheter procedure. CONCLUSION In this prospective study, we describe a new technique to avoid tricuspid valve damage and facilitate delivery of the PAD device.
Collapse
Affiliation(s)
- Mathilde Meot
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, Hôpital Necker Enfants Malades, 75015 Paris, France.
| | - Régis Gaudin
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, Hôpital Necker Enfants Malades, 75015 Paris, France
| | - Isabelle Szezepanski
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, Hôpital Necker Enfants Malades, 75015 Paris, France
| | - Fanny Bajolle
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, Hôpital Necker Enfants Malades, 75015 Paris, France
| | - Damien Bonnet
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, Hôpital Necker Enfants Malades, 75015 Paris, France; Université de Paris, 75006 Paris, France
| | - Sophie Malekzadeh-Milani
- Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, Hôpital Necker Enfants Malades, 75015 Paris, France
| |
Collapse
|
43
|
Chen YJ, Chu WY, Yu WH, Chen CJ, Chia ST, Wang JN, Lin YC, Wei YJ. Massive Gastric Hemorrhage after Indomethacin Therapy: A Rare Presentation and Critical Management in an Extremely Preterm Infant. CHILDREN-BASEL 2021; 8:children8070545. [PMID: 34202886 PMCID: PMC8304301 DOI: 10.3390/children8070545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 06/03/2021] [Accepted: 06/21/2021] [Indexed: 11/16/2022]
Abstract
Indomethacin has been widely used in preterm infants with hemodynamically significant patent ductus arteriosus (PDA). Gastrointestinal complications of indomethacin have been reported in 5% of treated neonates. However, massive gastric mucosa hemorrhage is a rarely reported complication. To the best of our knowledge, the infant in this report is the smallest reported in the literature to have undergone successful surgery for such a complication. A male preterm infant weighing 566 g was born at 252/7 weeks of gestational age without a complicated maternal history. Soon after birth, he received nasal noninvasive respiratory support and minimal feeding. PDA was observed since the first day of life (DOL), treatments were initiated on the second DOL for the hemodynamical significance, and PDA was closed after two courses of indomethacin therapy (0.2 mg/kg). At midnight on the seventh DOL, generalized pallor, bloody gastric drainage, and a distended stomach were observed. Massive gastric bleeding was suspected. He suffered from intermittent hypotension, which was corrected with blood products and fluid resuscitation under monitoring with a radial arterial line. Gastric lavage with cooling saline was performed twice but in vain. Prior to surgical consultation, intravascular volume transfusion was given twice. An exploratory laparotomy was arranged after obtaining the parents' consent. Blood oozing from the gastric mucosa was observed through gastrostomy and was successfully stopped via epinephrine-soaked gauze compression. After the operation, his clinical course remained uneventful, and he was discharged without neurological anomaly at two-year follow-up. Physicians need to be cautious of indomethacin's effect on platelet dysfunction in preterm infants with multiple predisposing factors. The tendency for mucosal bleeding should be continuously monitored after indomethacin therapy.
Collapse
Affiliation(s)
- Yen-Ju Chen
- Department of Pediatrics, National Cheng Kung University Hospital, College of Medicine, National Cheng-Kung University, Tainan 704302, Taiwan; (Y.-J.C.); (W.-H.Y.); (J.-N.W.)
| | - Wei-Ying Chu
- Department of Pediatrics, Tainan Hospital, Ministry of Health and Welfare, Tainan 700007, Taiwan;
| | - Wen-Hao Yu
- Department of Pediatrics, National Cheng Kung University Hospital, College of Medicine, National Cheng-Kung University, Tainan 704302, Taiwan; (Y.-J.C.); (W.-H.Y.); (J.-N.W.)
| | - Chau-Jing Chen
- Department of Surgery, Tainan Sinlau Hospital, Tainan 701002, Taiwan;
- Department of Surgery, College of Medicine, National Cheng-Kung University, Tainan 701401, Taiwan;
| | - Shu-Ti Chia
- Department of Surgery, College of Medicine, National Cheng-Kung University, Tainan 701401, Taiwan;
| | - Jieh-Neng Wang
- Department of Pediatrics, National Cheng Kung University Hospital, College of Medicine, National Cheng-Kung University, Tainan 704302, Taiwan; (Y.-J.C.); (W.-H.Y.); (J.-N.W.)
| | - Yung-Chieh Lin
- Department of Pediatrics and Neonatology, Nagoya City University Graduate School of Medical Sciences, Nagoya 467-8601, Japan
- Correspondence: (Y.-C.L.); (Y.-J.W.); Tel.: +81-052-853-8244 (Y.-C.L.); +886-62-353-535 (ext. 4189) (Y.-J.W.)
| | - Yu-Jen Wei
- Department of Pediatrics, National Cheng Kung University Hospital, College of Medicine, National Cheng-Kung University, Tainan 704302, Taiwan; (Y.-J.C.); (W.-H.Y.); (J.-N.W.)
- Correspondence: (Y.-C.L.); (Y.-J.W.); Tel.: +81-052-853-8244 (Y.-C.L.); +886-62-353-535 (ext. 4189) (Y.-J.W.)
| |
Collapse
|
44
|
Paudel G, Johnson JN, Philip R, Tailor N, Fahnhorst S, Briceno-Medina M, Stecchi N, Waller BR, Sathanandam S. Echocardiographic versus Angiographic Measurement of the Patent Ductus Arteriosus in Extremely Low Birth Weight Infants and the Utility of Echo Guidance for Transcatheter Closure. J Am Soc Echocardiogr 2021; 34:1086-1094. [PMID: 34139301 DOI: 10.1016/j.echo.2021.06.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 06/08/2021] [Accepted: 06/08/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND Transthoracic echocardiography (TTE) is increasingly utilized for guiding transcatheter closure of patent ductus arteriosus (PDA) in extremely low birth weight (ELBW) infants. The objectives of this study were to compare PDA size measurements by TTE with angiographic measurements and to describe TTE techniques used in guiding transcatheter PDA closure (TCPC) in ELBW infants. METHODS One hundred twenty-five consecutive ELBW infants (gestational age < 27 weeks, birth weight < 1 kg) who underwent TCPC before 8 weeks of age under TTE guidance were included. Patent ductus arteriosus sizes were measured from the procedural TTE and angiograms retrospectively by blinded observers. The TTE PDA diameters at the aortic (ED1) and pulmonary end (ED2) were compared with the corresponding angiographic diameters (CD1 and CD2). The TTE PDA lengths, obtained by two techniques (EL1, a straight line between ED1 and ED2; and EL2, a curvilinear line along the PDA), were compared with the PDA length by angiography (CL). Transthoracic echocardiography was used to guide accurate device positioning within the PDA. RESULTS The procedure weight was 600-1,460 g. The TTE and angiographic PDA diameters were comparable (mean ED1 vs CD1 = 4.5 ± 0.68 vs 4.4 ± 0.85 mm, P = .26; and mean ED2 vs CD2 = 3.1 ± 0.72 vs 3.2 ± 0.94 mm, P = .14). The angiographic length was underestimated by EL1 by 2.6 ± 1.6 mm (P < .0001), while EL2 estimated it better (mean EL2 vs CL = 11.0 ± 1.83 vs 10.8 ± 2.15 mm; P = .40). Transcatheter PDA closure was successful in 100% of the cases using TTE guidance. There were no intraprocedural complications. CONCLUSIONS Transthoracic echocardiography guidance during TCPC in ELBW infants eliminates the need for aortograms via femoral arterial access, preventing the complications associated with it. Transthoracic echocardiography PDA measurements are comparable to angiographic measurements, thereby assisting in appropriate device size selection.
Collapse
Affiliation(s)
- Govinda Paudel
- Division of Pediatric Cardiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee.
| | - Jason N Johnson
- Division of Pediatric Cardiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee; Division of Pediatric Radiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Ranjit Philip
- Division of Pediatric Cardiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Neil Tailor
- Division of Pediatric Cardiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Sarah Fahnhorst
- Division of Pediatric Cardiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Mario Briceno-Medina
- Division of Pediatric Cardiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Nathan Stecchi
- Division of Pediatric Cardiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee
| | - B Rush Waller
- Division of Pediatric Cardiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Shyam Sathanandam
- Division of Pediatric Cardiology, Le Bonheur Children's Hospital, University of Tennessee Health Science Center, Memphis, Tennessee
| |
Collapse
|
45
|
Warnock A, Szatkowski L, Lakshmanan A, Lee L, Kelsall W. Surgical management of patent ductus arteriosus in pre-term infants - a british paediatric surveillance study. BMC Pediatr 2021; 21:270. [PMID: 34107888 PMCID: PMC8187455 DOI: 10.1186/s12887-021-02734-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 05/21/2021] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND This study aimed to provide UK data describing the incidence of patent ductus arteriosus (PDA) surgery in the neonatal population, including: pre-ligation management, and outcomes until discharge. We used British Paediatric Surveillance Unit (BPSU) methodology; collecting data via questionnaires for preterm neonates undergoing PDA ligation (PDAL) between 1st Sept 2012 - 30th Sept 2013. Infants born less than 37 weeks gestation, who underwent PDAL prior to discharge home, with no other structural cardiac abnormality, were included. Information collected included: patient demographics, pre and post-operative clinical characteristics, pre-operative medical management, post-operative complications and outcome. RESULTS Over the study, 263 infants underwent PDAL an incidence of 3.07 per 10,000 live births. 88% were born extremely preterm (< 28 weeks) and 60% were male. The commonest reasons for ligation were inability to wean respiratory support (83.7%) and haemodynamically significant PDA (87.8%). Pre-operatively 65.7% received medical therapy. Surgery was performed at a median age of 33 days (range 9-260, IQR 24-48); the corrected age was less than 31 + 6 week in 50.6% babies at PDAL. Most, (90%), of procedures were open ligation; only 9 (3.4%) were catheter occlusions (PDACO). 20.5% of patients had post-operative complications. The 30-day mortality was 3%, with 93.5% surviving to hospital discharge. CONCLUSION This study showed there was little consensus over medical and surgical management of the PDA or timing of surgery.
Collapse
Affiliation(s)
- A Warnock
- Neonatal Unit, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - L Szatkowski
- Division of Epidemiology and Public Health, School of Medicine, University of Nottingham, Nottingham, UK
| | - A Lakshmanan
- Neonatal Unit, University Hospitals of Coventry and Warwickshire, Coventry, UK
| | - L Lee
- Neonatal Unit, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - W Kelsall
- Neonatal Unit, Cambridge University Foundation Trust, Cambridge, CB2 2QQ, UK.
| |
Collapse
|
46
|
Philip R, Tailor N, Johnson JN, Apalodimas L, Cunningham J, Hoy J, Waller Iii BR, Sathanandam S. Single-Center Experience of 100 Consecutive Percutaneous Patent Ductus Arteriosus Closures in Infants ≤1000 Grams. Circ Cardiovasc Interv 2021; 14:e010600. [PMID: 34092088 DOI: 10.1161/circinterventions.121.010600] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Ranjit Philip
- University of Tennessee Health Science Centre, LeBonheur Children's Hospital, Memphis
| | - Neil Tailor
- University of Tennessee Health Science Centre, LeBonheur Children's Hospital, Memphis
| | - Jason N Johnson
- University of Tennessee Health Science Centre, LeBonheur Children's Hospital, Memphis
| | - Leah Apalodimas
- University of Tennessee Health Science Centre, LeBonheur Children's Hospital, Memphis
| | - Jorden Cunningham
- University of Tennessee Health Science Centre, LeBonheur Children's Hospital, Memphis
| | - Judy Hoy
- University of Tennessee Health Science Centre, LeBonheur Children's Hospital, Memphis
| | - B Rush Waller Iii
- University of Tennessee Health Science Centre, LeBonheur Children's Hospital, Memphis
| | - Shyam Sathanandam
- University of Tennessee Health Science Centre, LeBonheur Children's Hospital, Memphis
| |
Collapse
|
47
|
Transcatheter patent ductus arteriosus closure in extremely premature infants. PROGRESS IN PEDIATRIC CARDIOLOGY 2021. [DOI: 10.1016/j.ppedcard.2021.101366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
48
|
Respiratory Trajectory after Invasive Interventions for Patent Ductus Arteriosus of Preterm Infants. CHILDREN-BASEL 2021; 8:children8050398. [PMID: 34063345 PMCID: PMC8156843 DOI: 10.3390/children8050398] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/06/2021] [Accepted: 05/13/2021] [Indexed: 12/14/2022]
Abstract
Invasive interventions have been conducted in preterm infants with significant patent ductus arteriosus (PDA) when medical treatment has failed, and methods of invasive intervention have been reported. Surgical ligation via lateral thoracotomy has been a well-established procedure for decades. Recently, transcatheter occlusion has been safely and feasibly applied to the premature population. However, little research has been conducted on the benefits of transcatheter occlusion in very-low-birth-weight (VLBW) infants compared to surgical ligation. This study compared transcatheter and surgical techniques in VLBW infants in terms of short-term respiratory outcomes. The medical records of 401 VLBW infants admitted to a tertiary hospital between September 2014 and January 2019 were retrospectively reviewed. Patients who were diagnosed with a congenital anomaly, a chromosomal anomaly, or congenital heart disease, except for an inter-atrial shunt, were excluded. The perinatal conditions, neonatal morbidities, periprocedural vital signs, and respiratory support trajectories were compared between the transcatheter-treated and surgically ligated group. A total of 31 eligible VLBW infants received invasive intervention: 14 were treated with transcatheter occlusion (Group A), and 17 infants were treated with surgical ligation (Group B). Respiratory outcomes were not statistically significant between the two groups, despite Group A showing a trend toward early improvement in post-intervention respiratory trajectory. In this small case study, a different trend in post-intervention respiratory trajectories was observed. Future research with larger case numbers should be conducted to address our preliminary observations in more detail.
Collapse
|
49
|
Percutaneous Closure of Patent Ductus Arteriosus in Infants 1.5 kg or Less: A Meta-Analysis. J Pediatr 2021; 230:84-92.e14. [PMID: 33098843 DOI: 10.1016/j.jpeds.2020.10.035] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To investigate technical success and safety of percutaneous patent ductus arteriosus closure in infants ≤1.5 kg. STUDY DESIGN A systematic review and meta-analysis was performed. Data sources included Scopus, Web of Science, Embase, CINAHL, Cochrane, and PubMed from inception to April 2020. Publications were included if they had a clear definition of the intervention as percutaneous patent ductus arteriosus closure in infants ≤1.5 kg. Data extraction was independently performed by multiple observers. Primary outcome was technical success and secondary outcomes were adverse events (AEs). Subgroup analysis was performed in infants ≤6.0 kg. Data were pooled by using a random-effects model. RESULTS We included 28 studies, including 373 infants ≤1.5 kg and 69 studies enrolling 1794 infants ≤6.0 kg. In patients ≤1.5 kg, technical success was 96% (95% CI, 93%-98%; P = .16; I2 = 23%). The overall incidence of AE was 27% (95% CI, 17%-38%; P < .001; I2 = 70%) and major AEs was 8% (95% CI, 5%-10%; P = .63; I2 = 0%). There were 5 deaths related to the procedure (2%; 95% CI, 1%-4%; P = .99; I2 = 0%); 4 of these deaths occurred in infants <0.8 kg. The probability of technical failure was inversely related to age at the time of the procedure (OR, 0.9; 95% CI, 0.830-0.974; P = .009). Weight at intervention has decreased over time and procedural success has increased. CONCLUSIONS Percutaneous patent ductus arteriosus closure is feasible in infants ≤1.5 kg with few major AEs. The procedural success rate is high, despite performing the intervention in smaller patients. PROSPERO REGISTRATION CRD42020145230.
Collapse
|
50
|
Markush D, Tsing JC, Gupta S, Berndsen NC, Radville G, Garg R, Zahn EM, Almeida-Jones M. Fate of the Left Pulmonary Artery and Thoracic Aorta After Transcatheter Patent Ductus Arteriosus Closure in Low Birth Weight Premature Infants. Pediatr Cardiol 2021; 42:628-636. [PMID: 33394112 PMCID: PMC7990822 DOI: 10.1007/s00246-020-02523-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Accepted: 12/04/2020] [Indexed: 01/07/2023]
Abstract
Transcatheter patent ductus arteriosus closure (TCPC) is an emerging treatment for low birth weight extremely premature neonates (EPNs). Left pulmonary artery (LPA) and descending aorta (DAO) obstruction are described device-related complications, however, data on mid- and long-term vascular outcomes are lacking. A retrospective analysis of EPNs who underwent successful TCPC at our institution from 03/2013 to 12/2018 was performed. Two-dimensional echocardiography and spectral Doppler velocities from various time points before and after TCPC were used to identify LPA and DAO flow disturbances. A total of 44 EPNs underwent successful TCPC at a median (range) procedural weight of 1150 g (755-2500 g). Thirty-two (73%) patients were closed with the AVP II and 12 (27%) with the Amplatzer Piccolo device. LPA and DAO velocities on average remained within normal limits and improved spontaneously in long-term follow up (26.1 months, range 1-75 months). One patient, who had concerning LPA flow characteristics immediately after device implant (peak velocity 2.6 m/s) developed progressive LPA stenosis requiring stent placement 3 months post-procedure. In the remaining infants, including 7 (16%) who developed LPA and 3 (7%) who developed DAO flow disturbances (range 2-2.4 m/s), all had progressive normalization of flow velocities over time. TCPC can be performed safely in EPNs with a low incidence of LPA and DAO obstruction. In the absence of significant progressive vascular obstruction in the early post-procedure period, mild increases in LPA and DAO flow velocities tend to improve spontaneously and normalize in long-term follow-up.
Collapse
Affiliation(s)
- Dor Markush
- Guerin Family Congenital Heart Program, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
- Department of Pediatrics, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
- Guerin Family Congenital Heart Program, Cedars-Sinai Smidt Heart Institute, 127 S. San Vicente Blvd, Suite A3600, Los Angeles, CA, 90048, USA.
| | - Jennifer C Tsing
- Guerin Family Congenital Heart Program, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Surbhi Gupta
- Department of Pediatrics, University of California Los Angeles, Los Angeles, CA, USA
| | - Nicole C Berndsen
- Guerin Family Congenital Heart Program, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | | | - Ruchira Garg
- Guerin Family Congenital Heart Program, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
- Department of Pediatrics, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Evan M Zahn
- Guerin Family Congenital Heart Program, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
- Department of Pediatrics, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Myriam Almeida-Jones
- Guerin Family Congenital Heart Program, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
- Department of Pediatrics, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| |
Collapse
|