1
|
Chen X, Dai Q, Qiu X, Luo X, Li Y. New nanosensor fabricated on single nanopore electrode filled with prussian blue and graphene quantum dots coated by polypyrrole for hydrogen peroxide sensing. Talanta 2024; 274:126043. [PMID: 38581852 DOI: 10.1016/j.talanta.2024.126043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 03/06/2024] [Accepted: 04/02/2024] [Indexed: 04/08/2024]
Abstract
Hydrogen peroxide (H2O2) is a common oxidant that plays an important role in many biological processes and is also an important medium analysis in various fields. In this work, a new electrochemical nanosensor capable of detecting and quantifying hydrogen peroxide was introduced. This nanosensor was fabricated by electrodepositing prussian blue (PB)/graphene quantum dots (GQDs)/polypyrrole (PPy) on single nanopore electrode etched from single gold nanoelectrode. This prepapred nanosensor exhibits good electrochemical response to hydrogen peroxide with high sensitivity and stability, with a linear response in the 2.0 and 80 μM by using amperometric method and differential pulse voltammetry (DPV) method. The limit of detections are 0.33 μM (S/N = 3) for amperometric method and 0.67 μM (S/N = 3) for differential pulse voltammetry (DPV) method, respectively. This nanosensor can be used for the determination of hydrogen peroxide in human urine, and can serve as a new electrochemical platform to monitor H2O2 release from single living cells due to its small overal dimension and high sensitivity.
Collapse
Affiliation(s)
- Xiaohu Chen
- Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, Key Laboratory of Functional Molecular Solids, Ministry of Education, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Qingshan Dai
- Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, Key Laboratory of Functional Molecular Solids, Ministry of Education, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Xia Qiu
- Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, Key Laboratory of Functional Molecular Solids, Ministry of Education, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Xianzhun Luo
- Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, Key Laboratory of Functional Molecular Solids, Ministry of Education, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Yongxin Li
- Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, Key Laboratory of Functional Molecular Solids, Ministry of Education, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China.
| |
Collapse
|
2
|
Zhu W, Wang J, Luo H, Luo B, Li X, Liu S, Li C. Electrical Characterization and Analysis of Single Cells and Related Applications. BIOSENSORS 2023; 13:907. [PMID: 37887100 PMCID: PMC10605054 DOI: 10.3390/bios13100907] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 08/26/2023] [Accepted: 09/01/2023] [Indexed: 10/28/2023]
Abstract
Biological parameters extracted from electrical signals from various body parts have been used for many years to analyze the human body and its behavior. In addition, electrical signals from cancer cell lines, normal cells, and viruses, among others, have been widely used for the detection of various diseases. Single-cell parameters such as cell and cytoplasmic conductivity, relaxation frequency, and membrane capacitance are important. There are many techniques available to characterize biomaterials, such as nanotechnology, microstrip cavity resonance measurement, etc. This article reviews single-cell isolation and sorting techniques, such as the micropipette separation method, separation and sorting system (dual electrophoretic array system), DEPArray sorting system (dielectrophoretic array system), cell selector sorting system, and microfluidic and valve devices, and discusses their respective advantages and disadvantages. Furthermore, it summarizes common single-cell electrical manipulations, such as single-cell amperometry (SCA), electrical impedance sensing (EIS), impedance flow cytometry (IFC), cell-based electrical impedance (CEI), microelectromechanical systems (MEMS), and integrated microelectrode array (IMA). The article also enumerates the application and significance of single-cell electrochemical analysis from the perspectives of CTC liquid biopsy, recombinant adenovirus, tumor cells like lung cancer DTCs (LC-DTCs), and single-cell metabolomics analysis. The paper concludes with a discussion of the current limitations faced by single-cell analysis techniques along with future directions and potential application scenarios.
Collapse
Affiliation(s)
- Weitao Zhu
- Clinical Medicine (Eight-Year Program), West China School of Medicine, Sichuan University, Chengdu 610044, China; (W.Z.); (J.W.)
| | - Jiaao Wang
- Clinical Medicine (Eight-Year Program), West China School of Medicine, Sichuan University, Chengdu 610044, China; (W.Z.); (J.W.)
| | - Hongzhi Luo
- Department of Laboratory Medicine, The Third Affiliated Hospital of Zunyi Medical University (The First People’s Hospital of Zunyi), Zunyi 563002, China;
| | - Binwen Luo
- School of Medicine, University of Electronic Science and Technology of China, Chengdu 610054, China;
| | - Xue Li
- Sichuan Hanyuan County People’s Hospital, Hanyuan 625300, China;
| | - Shan Liu
- Sichuan Provincial Key Laboratory for Human Disease Gene Study, Department of Medical Genetics, Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital, University of Electronic Science and Technology of China, Chengdu 610072, China
| | - Chenzhong Li
- Biomedical Engineering, School of Medicine, The Chinese University of Hong Kong, Shenzhen 518172, China;
| |
Collapse
|
3
|
Cardoso MA, Gonçalves HMR, Davis F. Reactive oxygen species in biological media are they friend or foe? Major In vivo and In vitro sensing challenges. Talanta 2023; 260:124648. [PMID: 37167678 DOI: 10.1016/j.talanta.2023.124648] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 04/07/2023] [Accepted: 05/04/2023] [Indexed: 05/13/2023]
Abstract
The role of Reactive Oxygen Species (ROS) on biological media has been shifting over the years, as the knowledge on the complex mechanism that lies in underneath their production and overall results has been growing. It has been known for some time that these species are associated with a number of health conditions. However, they also participate in the immunoactivation cascade process, and can have an active role in theranostics. Macrophages, for example, react to the presence of pathogens through ROS production, potentially allowing the development of new therapeutic strategies. However, their short lifetime and limited spatial distribution of ROS have been limiting factors to the development and understanding of this phenomenon. Even though, ROS have shown successful theranostic applications, e.g., photodynamic therapy, their wide applicability has been hampered by the lack of effective tools for monitoring these processes in real time. Thus the development of innovative sensing strategies for in vivo monitoring of the balance between ROS concentration and the resultant immune response is of the utmost relevance. Such knowledge could lead to major breakthroughs towards the development of more effective treatments for neurodegenerative diseases. Within this review we will present the current understanding on the interaction mechanisms of ROS with biological systems and their overall effect. Additionally, the most promising sensing tools developed so far, for both in vivo and in vitro tracking will be presented along with their main limitations and advantages. This review focuses on the four main ROS that have been studied these are: singlet oxygen species, hydrogen peroxide, hydroxyl radical and superoxide anion.
Collapse
Affiliation(s)
- Marita A Cardoso
- REQUIMTE, Instituto Superior de Engenharia Do Porto, 4200-072, Porto, Portugal
| | - Helena M R Gonçalves
- REQUIMTE, Instituto Superior de Engenharia Do Porto, 4200-072, Porto, Portugal; Biosensor NTech - Nanotechnology Services, Lda, Avenida da Liberdade, 249, 1° Andar, 1250-143, Lisboa, Portugal.
| | - Frank Davis
- Department of Engineering and Applied Design University of Chichester, Bognor Regis, West Sussex, PO21 1HR, UK
| |
Collapse
|
4
|
Electrochemical sensors based on antimony tin oxide-Prussian blue screen-printed electrode and PEDOT-Prussian blue for potassium ion detection. J Solid State Electrochem 2023. [DOI: 10.1007/s10008-023-05392-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
5
|
Micro- and nano-devices for electrochemical sensing. Mikrochim Acta 2022; 189:459. [DOI: 10.1007/s00604-022-05548-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 11/02/2022] [Indexed: 11/24/2022]
Abstract
AbstractElectrode miniaturization has profoundly revolutionized the field of electrochemical sensing, opening up unprecedented opportunities for probing biological events with a high spatial and temporal resolution, integrating electrochemical systems with microfluidics, and designing arrays for multiplexed sensing. Several technological issues posed by the desire for downsizing have been addressed so far, leading to micrometric and nanometric sensing systems with different degrees of maturity. However, there is still an endless margin for researchers to improve current strategies and cope with demanding sensing fields, such as lab-on-a-chip devices and multi-array sensors, brain chemistry, and cell monitoring. In this review, we present current trends in the design of micro-/nano-electrochemical sensors and cutting-edge applications reported in the last 10 years. Micro- and nanosensors are divided into four categories depending on the transduction mechanism, e.g., amperometric, impedimetric, potentiometric, and transistor-based, to best guide the reader through the different detection strategies and highlight major advancements as well as still unaddressed demands in electrochemical sensing.
Graphical Abstract
Collapse
|
6
|
Tibbits G, Mohamed A, Gelston S, Flurin L, Raval YS, Greenwood‐Quaintance K, Patel R, Beyenal H. Efficacy and toxicity of hydrogen peroxide producing electrochemical bandages in a porcine explant biofilm model. J Appl Microbiol 2022; 133:3755-3767. [PMID: 36073322 PMCID: PMC9671841 DOI: 10.1111/jam.15812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 06/30/2022] [Accepted: 08/30/2022] [Indexed: 01/11/2023]
Abstract
AIMS Effects of H2 O2 producing electrochemical-bandages (e-bandages) on methicillin-resistant Staphylococcus aureus colonization and biofilm removal were assessed using a porcine explant biofilm model. Transport of H2 O2 produced from the e-bandage into explant tissue and associated potential toxicity were evaluated. METHODS AND RESULTS Viable prokaryotic cells from infected explants were quantified after 48 h treatment with e-bandages in three ex vivo S. aureus infection models: (1) reducing colonization, (2) removing young biofilms and (3) removing mature biofilms. H2 O2 concentration-depth profiles in explants/biofilms were measured using microelectrodes. Reductions in eukaryotic cell viability of polarized and nonpolarized noninfected explants were compared. e-Bandages effectively reduced S. aureus colonization (p = 0.029) and reduced the viable prokaryotic cell concentrations of young biofilms (p = 0.029) with limited effects on mature biofilms (p > 0.1). H2 O2 penetrated biofilms and explants and reduced eukaryotic cell viability by 32-44% compared to nonpolarized explants. CONCLUSIONS H2 O2 producing e-bandages were most active when used to reduce colonization and remove young biofilms rather than to remove mature biofilms. SIGNIFICANCE AND IMPACT OF STUDY The described e-bandages reduced S. aureus colonization and young S. aureus biofilms in a porcine explant wound model, supporting their further development as an antibiotic-free alternative for managing biofilm infections.
Collapse
Affiliation(s)
- Gretchen Tibbits
- The Gene and Linda Voiland School of Chemical Engineering and BioengineeringWashington State UniversityPullmanWashingtonUSA
| | - Abdelrhman Mohamed
- The Gene and Linda Voiland School of Chemical Engineering and BioengineeringWashington State UniversityPullmanWashingtonUSA
| | - Suzanne Gelston
- The Gene and Linda Voiland School of Chemical Engineering and BioengineeringWashington State UniversityPullmanWashingtonUSA
| | - Laure Flurin
- Division of Clinical MicrobiologyMayo ClinicRochesterMinnesotaUSA
| | - Yash S. Raval
- Division of Clinical MicrobiologyMayo ClinicRochesterMinnesotaUSA
| | | | - Robin Patel
- Division of Clinical MicrobiologyMayo ClinicRochesterMinnesotaUSA,Division of Public Health, Infectious Diseases and Occupational MedicineMayo ClinicRochesterMinnesotaUSA
| | - Haluk Beyenal
- The Gene and Linda Voiland School of Chemical Engineering and BioengineeringWashington State UniversityPullmanWashingtonUSA
| |
Collapse
|
7
|
Sciurti E, Biscaglia F, Prontera C, Giampetruzzi L, Blasi L, Francioso L. Nanoelectrodes for Intracellular and Intercellular electrochemical detection: working principles, fabrication techniques and applications. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.117125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
8
|
Patella B, Vincenzo SD, Zanca C, Bollaci L, Ferraro M, Giuffrè MR, Cipollina C, Bruno MG, Aiello G, Russo M, Inguanta R, Pace E. Electrochemical Quantification of H 2O 2 Released by Airway Cells Growing in Different Culture Media. MICROMACHINES 2022; 13:mi13101762. [PMID: 36296115 PMCID: PMC9611932 DOI: 10.3390/mi13101762] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 10/11/2022] [Accepted: 10/12/2022] [Indexed: 05/30/2023]
Abstract
Quantification of oxidative stress is a challenging task that can help in monitoring chronic inflammatory respiratory airway diseases. Different studies can be found in the literature regarding the development of electrochemical sensors for H2O2 in cell culture medium to quantify oxidative stress. However, there are very limited data regarding the impact of the cell culture medium on the electrochemical quantification of H2O2. In this work, we studied the effect of different media (RPMI, MEM, DMEM, Ham's F12 and BEGM/DMEM) on the electrochemical quantification of H2O2. The used electrode is based on reduced graphene oxide (rGO) and gold nanoparticles (AuNPs) and was obtained by co-electrodeposition. To reduce the electrode fouling by the medium, the effect of dilution was investigated using diluted (50% v/v in PBS) and undiluted media. With the same aim, two electrochemical techniques were employed, chronoamperometry (CH) and linear scan voltammetry (LSV). The influence of different interfering species and the effect of the operating temperature of 37 °C were also studied in order to simulate the operation of the sensor in the culture plate. The LSV technique made the sensor adaptable to undiluted media because the test time is short, compared with the CH technique, reducing the electrode fouling. The long-term stability of the sensors was also evaluated by testing different storage conditions. By storing the electrode at 4 °C, the sensor performance was not reduced for up to 21 days. The sensors were validated measuring H2O2 released by two different human bronchial epithelial cell lines (A549, 16HBE) and human primary bronchial epithelial cells (PBEC) grown in RPMI, MEM and BEGM/DMEM media. To confirm the results obtained with the sensor, the release of reactive oxygen species was also evaluated with a standard flow cytometry technique. The results obtained with the two techniques were very similar. Thus, the LSV technique permits using the proposed sensor for an effective oxidative stress quantification in different culture media and without dilution.
Collapse
Affiliation(s)
- Bernardo Patella
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | - Serena Di Vincenzo
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
| | - Claudio Zanca
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | - Luciano Bollaci
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | - Maria Ferraro
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
| | | | - Chiara Cipollina
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
- Ri.MED Foundation, 90146 Palermo, Italy
| | | | - Giuseppe Aiello
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | | | | | - Elisabetta Pace
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
| |
Collapse
|
9
|
Abstract
Over the years, the engineering aspect of nanotechnology has been significantly exploited. Medical intervention strategies have been developed by leveraging existing molecular biology knowledge and combining it with nanotechnology tools to improve outcomes. However, little attention has been paid to harnessing the strengths of nanotechnology as a biological discovery tool. Fundamental understanding of controlling dynamic biological processes at the subcellular level is key to developing personalized therapeutic and diagnostic interventions. Single-cell analyses using intravital microscopy, expansion microscopy, and microfluidic-based platforms have been helping to better understand cell heterogeneity in healthy and diseased cells, a major challenge in oncology. Also, single-cell analysis has revealed critical signaling pathways and biological intracellular components with key biological functions. The physical manipulation enabled by nanotools can allow real-time monitoring of biological changes at a single-cell level by sampling intracellular fluid from the same cell. The formation of intercellular highways by nanotube-like structures has important clinical implications such as metastasis development. The integration of nanomaterials into optical and molecular imaging techniques has rendered valuable morphological, structural, and biological information. Nanoscale imaging unravels mechanisms of temporality by enabling the visualization of nanoscale dynamics never observed or measured between individual cells with standard biological techniques. The exceptional sensitivity of nanozymes, artificial enzymes, make them perfect components of the next-generation mobile diagnostics devices. Here, we highlight these impactful cancer-related biological discoveries enabled by nanotechnology and producing a paradigm shift in cancer research and oncology.
Collapse
Affiliation(s)
- Carolina Salvador-Morales
- Nanodelivery Systems and Devices Branch, Cancer Imaging Program, Division of Cancer Treatment and Diagnosis, National Cancer Institute, National Institutes of Health, Rockville, Maryland 20850, United States
| | - Piotr Grodzinski
- Nanodelivery Systems and Devices Branch, Cancer Imaging Program, Division of Cancer Treatment and Diagnosis, National Cancer Institute, National Institutes of Health, Rockville, Maryland 20850, United States
| |
Collapse
|
10
|
Wu WT, Chen X, Jiao YT, Fan WT, Liu YL, Huang WH. Versatile Construction of Biomimetic Nanosensors for Electrochemical Monitoring of Intracellular Glutathione. Angew Chem Int Ed Engl 2022; 61:e202115820. [PMID: 35134265 DOI: 10.1002/anie.202115820] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Indexed: 11/08/2022]
Abstract
The current strategies for nanoelectrode functionalization usually involve sophisticated modification procedures, uncontrollable and unstable modifier assembly, as well as a limited variety of modifiers. To address this issue, we propose a versatile strategy for large-scale synthesis of biomimetic molecular catalysts (BMCs) modified nanowires (NWs) to construct functionalized electrochemical nanosensors. This design protocol employs an easy, controllable and stable assembly of diverse BMCs-poly(3,4-ethylenedioxythiophene) (PEDOT) composites on conductive NWs. The intrinsic catalytic activity of BMCs combined with outstanding electron transfer ability of conductive polymer enables the nanosensors to sensitively and selectively detect various biomolecules. Further application of sulfonated cobalt phthalocyanine functionalized nanosensors achieves real-time electrochemical monitoring of intracellular glutathione levels and its redox homeostasis in single living cells for the first time.
Collapse
Affiliation(s)
- Wen-Tao Wu
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Xi Chen
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Yu-Ting Jiao
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Wen-Ting Fan
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Yan-Ling Liu
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Wei-Hua Huang
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| |
Collapse
|
11
|
Wu W, Chen X, Jiao Y, Fan W, Liu Y, Huang W. Versatile Construction of Biomimetic Nanosensors for Electrochemical Monitoring of Intracellular Glutathione. Angew Chem Int Ed Engl 2022. [DOI: 10.1002/ange.202115820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Wen‐Tao Wu
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences Wuhan University Wuhan 430072 China
| | - Xi Chen
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences Wuhan University Wuhan 430072 China
| | - Yu‐Ting Jiao
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences Wuhan University Wuhan 430072 China
| | - Wen‐Ting Fan
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences Wuhan University Wuhan 430072 China
| | - Yan‐Ling Liu
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences Wuhan University Wuhan 430072 China
| | - Wei‐Hua Huang
- Sauvage Center for Molecular Sciences, College of Chemistry and Molecular Sciences Wuhan University Wuhan 430072 China
| |
Collapse
|
12
|
Wang N, Wang D, Pan R, Wang D, Jiang D, Chen HY. Self-Referenced Nanopipette for Electrochemical Analysis of Hydrogen Peroxide in the Nucleus of a Single Living Cell. Anal Chem 2021; 93:10744-10749. [PMID: 34314583 DOI: 10.1021/acs.analchem.0c05025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
In a typical intracellular electroanalytical measurement, a nanoelectrode is located inside a living cell and a reference electrode outside the cell. This setup faces a problem to drop a certain potential across the cellular plasma membrane that might interrupt the cellular activity. To solve this problem, a self-referenced nanopipette is assembled by incorporating a reference electrode inside the nanocapillary, with a Pt ring at the tip as the electrochemical surface. The potential applied between the Pt ring and the reference electrode is restricted inside the capillary and thus has a negligible effect on the surrounding cellular environment. Using this new setup, the nanopipette pierces into the nucleus of a single living cell for the measurement of hydrogen peroxide under oxidative stress. It is found that a lesser amount of hydrogen peroxide is measured in the nucleus compared with the cytoplasm, revealing uneven oxidative stress inside the cell. The result will not only greatly improve the current setup for intracellular electrochemical analysis but also provide biological information of the compartment inside the living cell.
Collapse
Affiliation(s)
- Nina Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210092, China
| | - Dongni Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210092, China
| | - Rongrong Pan
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210092, China
| | - Dengchao Wang
- School of Chemical Sciences, University of Chinese Academy of Science, Beijing 100190, China
| | - Dechen Jiang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210092, China
| | - Hong-Yuan Chen
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210092, China
| |
Collapse
|
13
|
Wang H, Hua H, Tang H, Li Y. Dual-signaling amplification strategy for glutathione sensing by using single gold nanoelectrodes. Anal Chim Acta 2021; 1166:338579. [PMID: 34022990 DOI: 10.1016/j.aca.2021.338579] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 04/05/2021] [Accepted: 04/23/2021] [Indexed: 01/18/2023]
Abstract
A new nanosensor for glutathione (GSH) detection by use of single nanoelectrodes has been developed through a dual-signaling ratiometric amplification strategy. Ag nanoparticles (Ag NPs) metalized DNA1 was modified on an Au nanoelectrode surface. Due to the strong affinity between Ag NP and GSH, Ag NPs could be removed by the addition of GSH. The remaining metalized DNA1 could hardly form a double strand, while the de-metalized DNA1 could hybrid with DNA2 and DNA3 to form a complex structure to adsorb methylene blue (MB), and then the electrochemical signal of differential pulse voltammetry (DPV) from MB oxidation could be observed. With the addition of GSH, the peak current of MB oxidation at about -0.27 V (IMB) increases, while the signal of Ag oxidation at about 0.1 V (IAg) decreases. It was found that there had a linear relationship between the ratio of dual-signal (IMB/IAg) and the GSH concentrations, which could be used to detect GSH. The ratiometric nanosensor is label-free, easy to operate, and can eliminate inherent system errors. Considering the advantages of nanoelectrodes, such as low IR drop, fast response, and small overall dimension, this developed nanosensor can be used for GSH detection living systems (e.g., cell lysate).
Collapse
Affiliation(s)
- Hao Wang
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Hongmei Hua
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Haoran Tang
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Yongxin Li
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China.
| |
Collapse
|
14
|
Sero JE, Stevens MM. Nanoneedle-Based Materials for Intracellular Studies. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1295:191-219. [PMID: 33543461 DOI: 10.1007/978-3-030-58174-9_9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Nanoneedles, defined as high aspect ratio structures with tip diameters of 5 to approximately 500 nm, are uniquely able to interface with the interior of living cells. Their nanoscale dimensions mean that they are able to penetrate the plasma membrane with minimal disruption of normal cellular functions, allowing researchers to probe the intracellular space and deliver or extract material from individual cells. In the last decade, a variety of strategies have been developed using nanoneedles, either singly or as arrays, to investigate the biology of cancer cells in vitro and in vivo. These include hollow nanoneedles for soluble probe delivery, nanocapillaries for single-cell biopsy, nano-AFM for direct physical measurements of cytosolic proteins, and a wide range of fluorescent and electrochemical nanosensors for analyte detection. Nanofabrication has improved to the point that nanobiosensors can detect individual vesicles inside the cytoplasm, delineate tumor margins based on intracellular enzyme activity, and measure changes in cell metabolism almost in real time. While most of these applications are currently in the proof-of-concept stage, nanoneedle technology is poised to offer cancer biologists a powerful new set of tools for probing cells with unprecedented spatial and temporal resolution.
Collapse
Affiliation(s)
- Julia E Sero
- Biology and Biochemistry Department, University of Bath, Claverton Down, Bath, UK
| | - Molly M Stevens
- Institute for Biomedical Engineering, Imperial College London, London, UK.
| |
Collapse
|
15
|
McCormick HK, Dick JE. Nanoelectrochemical quantification of single-cell metabolism. Anal Bioanal Chem 2020; 413:17-24. [PMID: 32915282 DOI: 10.1007/s00216-020-02899-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 08/10/2020] [Accepted: 08/18/2020] [Indexed: 12/12/2022]
Abstract
At the most fundamental level, the behavior of tissue is governed by the activity of its single cells. A detailed examination of single-cell biology is necessary in order to gain a deeper understanding of disease progression. While single-cell genomics and transcriptomics are mature due to robust amplification strategies, the metabolome is difficult to quantify. Nanoelectrochemical techniques stand poised to quantify single-cell metabolism as a result of the fabrication of nanoelectrodes, which allow one to make intracellular electrochemical measurements. This article is concerned with intracellular nanoelectrochemistry, focusing on the sensitive and selective quantification of various metabolites within a single, living cell. We will review the strong literature behind this field, discuss the potential deleterious effects of passing charge inside cells, and provide future outlooks for this promising avenue of inquiry. We also present a mathematical relationship based on Faraday's Law and bulk electrolysis theory to examine the consumption of analyte within a cell due to passing charge at the nanotip.Graphical abstract.
Collapse
Affiliation(s)
- Hadley K McCormick
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA
| | - Jeffrey E Dick
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA. .,Lineberger Comprehensive Cancer Center, School of Medicine, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA.
| |
Collapse
|
16
|
Hellmann A, Daboss S, Zink F, Hartmann C, Radermacher P, Kranz C. Electrocatalytically modified microelectrodes for the detection of hydrogen peroxide at blood cells from swine with induced trauma. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136458] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
17
|
Chen R, Alanis K, Welle TM, Shen M. Nanoelectrochemistry in the study of single-cell signaling. Anal Bioanal Chem 2020; 412:6121-6132. [PMID: 32424795 DOI: 10.1007/s00216-020-02655-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Revised: 04/02/2020] [Accepted: 04/08/2020] [Indexed: 12/28/2022]
Abstract
Label-free biosensing has been the dream of scientists and biotechnologists as reported by Vollmer and Arnold (Nat Methods 5:591-596, 2008). The ability of examining living cells is crucial to cell biology as noted by Fang (Int J Electrochem 2011:460850, 2011). Chemical measurement with electrodes is label-free and has demonstrated capability of studying living cells. In recent years, nanoelectrodes of different functionality have been developed. These nanometer-sized electrodes, coupled with scanning electrochemical microscopy (SECM), have further enabled nanometer spatial resolution study in aqueous environments. Developments in the field of nanoelectrochemistry have allowed measurement of signaling species at single cells, contributing to better understanding of cell biology. Leading studies using nanoelectrochemistry of a variety of cellular signaling molecules, including redox-active neurotransmitter (e.g., dopamine), non-redox-active neurotransmitter (e.g., acetylcholine), reactive oxygen species (ROS), and reactive nitrogen species (RNS), are reviewed here.
Collapse
Affiliation(s)
- Ran Chen
- Department of Chemistry, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, IL, 61801, USA
| | - Kristen Alanis
- Department of Chemistry, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, IL, 61801, USA
| | - Theresa M Welle
- Department of Chemistry, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, IL, 61801, USA
| | - Mei Shen
- Department of Chemistry, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, IL, 61801, USA.
| |
Collapse
|
18
|
Polymer/enzyme-modified HF-etched carbon nanoelectrodes for single-cell analysis. Bioelectrochemistry 2020; 133:107487. [PMID: 32120322 DOI: 10.1016/j.bioelechem.2020.107487] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 02/01/2020] [Accepted: 02/14/2020] [Indexed: 11/20/2022]
Abstract
Carbon-based nanoelectrodes fabricated by means of pyrolysis of an alkane precursor gas purged through a glass capillary and subsequently etched with HF were modified with redox polymer/enzyme films for the detection of glucose at the single-cell level. Glucose oxidase (GOx) was immobilized and electrically wired by means of an Os-complex-modified redox polymer in a sequential dip coating process. For the synthesis of the redox polymer matrix, a poly(1-vinylimidazole-co-acrylamide)-based backbone was used that was first modified with the electron transfer mediator [Os(bpy)2Cl]+ (bpy = 2,2'-bipyridine) followed by the conversion of the amide groups within the acrylamide monomer into hydrazide groups in a polymer-analogue reaction. The hydrazide groups react readily with bifunctional epoxide-based crosslinkers ensuring high film stability. Insertion of the nanometre-sized polymer/enzyme modified electrodes into adherently growing single NG108-15 cells resulted in a positive current response correlating with the intracellular glucose concentration. Moreover, the nanosensors showed a stable current output without significant loss in performance after intracellular measurements.
Collapse
|
19
|
Marquitan M, Mark MD, Ernst A, Muhs A, Herlitze S, Ruff A, Schuhmann W. Glutamate detection at the cellular level by means of polymer/enzyme multilayer modified carbon nanoelectrodes. J Mater Chem B 2020; 8:3631-3639. [DOI: 10.1039/c9tb02461a] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Carbon nanoelectrodes in the sub-micron range were modified with an enzyme cascade immobilized in a spatially separated polymer double layer system for the detection of glutamate at the cellular level.
Collapse
Affiliation(s)
- Miriam Marquitan
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Melanie D. Mark
- Department of General Zoology and Neurobiology Ruhr University Bochum Universitätsstr. 150
- D-44780 Bochum
- Germany
| | - Andrzej Ernst
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Anna Muhs
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Stefan Herlitze
- Department of General Zoology and Neurobiology Ruhr University Bochum Universitätsstr. 150
- D-44780 Bochum
- Germany
| | - Adrian Ruff
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Wolfgang Schuhmann
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| |
Collapse
|
20
|
Jiang H, Zhang XW, Liao QL, Wu WT, Liu YL, Huang WH. Electrochemical Monitoring of Paclitaxel-Induced ROS Release from Mitochondria inside Single Cells. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1901787. [PMID: 31183973 DOI: 10.1002/smll.201901787] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 05/22/2019] [Indexed: 05/27/2023]
Abstract
Mitochondria are believed to be the major source of intracellular reactive oxygen species (ROS). However, in situ, real-time and quantitative monitoring of ROS release from mitochondria that are present in their cytosolic environment remains a great challenge. In this work, a platinized SiC@C nanowire electrode is placed into a single cell for in situ detection of ROS signals from intracellular mitochondria, and antineoplastic agent (paclitaxel) induced ROS production is successfully recorded. Further investigations indicate that complex IV (cytochrome c oxidase, COX) is the principal site for ROS generation, and significantly more ROS are generated from mitochondria in cancer cells than that from normal cells. This work provides an effective approach to directly monitor intracellular mitochondria by nanowire electrodes, and consequently obtains important physiological evidence on antineoplastic agent-induced ROS generation, which will be of great benefit for better understanding of chemotherapy at subcellular levels.
Collapse
Affiliation(s)
- Hong Jiang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Xin-Wei Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Quan-Lan Liao
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Wen-Tao Wu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Yan-Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Wei-Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| |
Collapse
|
21
|
Bettazzi F, Palchetti I. Nanotoxicity assessment: A challenging application for cutting edge electroanalytical tools. Anal Chim Acta 2019; 1072:61-74. [DOI: 10.1016/j.aca.2019.04.035] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 04/07/2019] [Accepted: 04/16/2019] [Indexed: 12/18/2022]
|
22
|
Zhang X, Oleinick A, Jiang H, Liao Q, Qiu Q, Svir I, Liu Y, Amatore C, Huang W. Electrochemical Monitoring of ROS/RNS Homeostasis Within Individual Phagolysosomes Inside Single Macrophages. Angew Chem Int Ed Engl 2019; 58:7753-7756. [DOI: 10.1002/anie.201902734] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 03/24/2019] [Indexed: 12/29/2022]
Affiliation(s)
- Xin‐Wei Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Alexander Oleinick
- PASTEUR, Départment de ChimieÉcole Normale SupérieurePSL, Research UniversitySorbonne UniversitésUPMC Univ. Paris 06 France
- CNRS 24 rue Lhomond 75005 Paris France
| | - Hong Jiang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Quan‐Lan Liao
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Quan‐Fa Qiu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Irina Svir
- PASTEUR, Départment de ChimieÉcole Normale SupérieurePSL, Research UniversitySorbonne UniversitésUPMC Univ. Paris 06 France
- CNRS 24 rue Lhomond 75005 Paris France
| | - Yan‐Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Christian Amatore
- PASTEUR, Départment de ChimieÉcole Normale SupérieurePSL, Research UniversitySorbonne UniversitésUPMC Univ. Paris 06 France
- CNRS 24 rue Lhomond 75005 Paris France
- State Key Laboratory of Physical Chemistry of Solid SurfacesCollege of Chemistry and Chemical EngineeringXiamen University Xiamen 361005 China
| | - Wei‐Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| |
Collapse
|
23
|
Amperometric sensing of hydrazine by using single gold nanopore electrodes filled with Prussian Blue and coated with polypyrrole and carbon dots. Mikrochim Acta 2019; 186:350. [PMID: 31093761 DOI: 10.1007/s00604-019-3486-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 05/05/2019] [Indexed: 01/26/2023]
Abstract
A nanoprobe for hydrazine sensing is described that is making use of a single gold nanopore electrode (SAuNPEs) that was modified by electro-deposition of Prussian Blue (PB) and then coated with a thin membrane of polypyrrole and carbon dots in order to enhance stability and catalytic activity. Best operated at a low potential of 0.3 V vs. Ag/AgCl, the nanosensor display good electrocatalytic activity towards the oxidation of hydrazine, with a linear response in the 0.5-80 μM hydrazine concentration range and a 0.18 μM detection limit (at S/N = 3). The method was applied to the determination of hydrazine in human urine. Graphical abstract Schematic presentation of the electrocatalytic oxidation of hydrazine using a single gold nanopore electrode that was modified by electro-deposition of Prussian Blue and then coated with a thin membrane of polypyrrole and carbon dots.
Collapse
|
24
|
Zhang X, Oleinick A, Jiang H, Liao Q, Qiu Q, Svir I, Liu Y, Amatore C, Huang W. Electrochemical Monitoring of ROS/RNS Homeostasis Within Individual Phagolysosomes Inside Single Macrophages. Angew Chem Int Ed Engl 2019. [DOI: 10.1002/ange.201902734] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Xin‐Wei Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Alexander Oleinick
- PASTEUR, Départment de ChimieÉcole Normale SupérieurePSL, Research UniversitySorbonne UniversitésUPMC Univ. Paris 06 France
- CNRS 24 rue Lhomond 75005 Paris France
| | - Hong Jiang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Quan‐Lan Liao
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Quan‐Fa Qiu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Irina Svir
- PASTEUR, Départment de ChimieÉcole Normale SupérieurePSL, Research UniversitySorbonne UniversitésUPMC Univ. Paris 06 France
- CNRS 24 rue Lhomond 75005 Paris France
| | - Yan‐Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| | - Christian Amatore
- PASTEUR, Départment de ChimieÉcole Normale SupérieurePSL, Research UniversitySorbonne UniversitésUPMC Univ. Paris 06 France
- CNRS 24 rue Lhomond 75005 Paris France
- State Key Laboratory of Physical Chemistry of Solid SurfacesCollege of Chemistry and Chemical EngineeringXiamen University Xiamen 361005 China
| | - Wei‐Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education)College of Chemistry and Molecular SciencesWuhan University Wuhan 430072 China
| |
Collapse
|
25
|
Electrochemical monitoring of reactive oxygen/nitrogen species and redox balance in living cells. Anal Bioanal Chem 2019; 411:4365-4374. [PMID: 31011787 DOI: 10.1007/s00216-019-01734-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 02/19/2019] [Accepted: 02/27/2019] [Indexed: 10/27/2022]
Abstract
Levels of reactive oxygen species (ROS) and reactive nitrogen species (RNS) in cells and cell redox balance are of great interest in live cells as they are correlated to several pathological and physiological conditions of living cells. ROS and RNS detection is limited due to their spatially restricted abundance: they are usually located in sub-cellular areas (e.g., in specific organelles) at low concentration. In this work, we will review and highlight the electrochemical approach to this bio-analytical issue. Combining electrochemical methods and miniaturization strategies, specific, highly sensitive, time, and spatially resolved measurements of cellular oxidative stress and redox balance analysis are possible. Graphical abstract In this work, we highlight and review the use of electrochemistry for the highly spatial and temporal resolved detection of ROS/RNS levels and of redox balance in living cells. These levels are central in several pathological and physiological conditions and the electrochemical approach is a vibrant bio-analytical trend in this field.
Collapse
|
26
|
Tang H, Zhu J, Wang D, Li Y. Dual-signal amplification strategy for miRNA sensing with high sensitivity and selectivity by use of single Au nanowire electrodes. Biosens Bioelectron 2019; 131:88-94. [DOI: 10.1016/j.bios.2019.02.023] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 01/15/2019] [Accepted: 02/01/2019] [Indexed: 12/15/2022]
|
27
|
Amarnath CA, Sawant SN. Tailoring synthesis strategies for polyaniline-prussian blue composite in view of energy storage and H2O2 sensing application. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2018.10.132] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
28
|
Hua H, Liu Y, Wang D, Li Y. Size-Dependent Voltammetry at Single Silver Nanoelectrodes. Anal Chem 2018; 90:9677-9681. [DOI: 10.1021/acs.analchem.8b02644] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Hongmei Hua
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, Anhui 241000, P.R. China
| | - Yong Liu
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, Anhui 241000, P.R. China
| | - Dongmei Wang
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, Anhui 241000, P.R. China
| | - Yongxin Li
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, Anhui 241000, P.R. China
| |
Collapse
|
29
|
Wilde P, Quast T, Aiyappa HB, Chen Y, Botz A, Tarnev T, Marquitan M, Feldhege S, Lindner A, Andronescu C, Schuhmann W. Towards Reproducible Fabrication of Nanometre‐Sized Carbon Electrodes: Optimisation of Automated Nanoelectrode Fabrication by Means of Transmission Electron Microscopy. ChemElectroChem 2018. [DOI: 10.1002/celc.201800600] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Patrick Wilde
- Analytical Chemistry – Center for Electrochemical Sciences (CES)Ruhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Thomas Quast
- Analytical Chemistry – Center for Electrochemical Sciences (CES)Ruhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Harshitha B. Aiyappa
- Analytical Chemistry – Center for Electrochemical Sciences (CES)Ruhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Yen‐Ting Chen
- Analytical Chemistry – Center for Electrochemical Sciences (CES)Ruhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Alexander Botz
- Analytical Chemistry – Center for Electrochemical Sciences (CES)Ruhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Tsvetan Tarnev
- Analytical Chemistry – Center for Electrochemical Sciences (CES)Ruhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Miriam Marquitan
- Analytical Chemistry – Center for Electrochemical Sciences (CES)Ruhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Stephan Feldhege
- Mechanical Workshop of the Faculty of Chemistry and BiochemistryRuhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Armin Lindner
- Mechanical Workshop of the Faculty of Chemistry and BiochemistryRuhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Corina Andronescu
- Analytical Chemistry – Center for Electrochemical Sciences (CES)Ruhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| | - Wolfgang Schuhmann
- Analytical Chemistry – Center for Electrochemical Sciences (CES)Ruhr-Universität Bochum Universitätsstraße 150 D-44780 Bochum Germany
| |
Collapse
|
30
|
Hosseini P, Wittstock G, Brand I. Infrared spectroelectrochemical analysis of potential dependent changes in cobalt hexacyanoferrate and copper hexacyanoferrate films on gold electrodes. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2017.12.029] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
31
|
Hua H, Liu Y, Guan X, Li Y. DNA nanosensors based on the use of single gold nanowire electrodes and Methylene Blue as an intercalator. Mikrochim Acta 2018; 185:152. [DOI: 10.1007/s00604-018-2703-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Accepted: 01/22/2018] [Indexed: 10/18/2022]
|
32
|
Bimetallic nanowire sensors for extracellular electrochemical hydrogen peroxide detection in HL-1 cell culture. J Solid State Electrochem 2017. [DOI: 10.1007/s10008-017-3829-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
33
|
Wang D, Xiao X, Xu S, Liu Y, Li Y. Electrochemical aptamer-based nanosensor fabricated on single Au nanowire electrodes for adenosine triphosphate assay. Biosens Bioelectron 2017; 99:431-437. [PMID: 28810234 DOI: 10.1016/j.bios.2017.08.020] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Revised: 07/30/2017] [Accepted: 08/08/2017] [Indexed: 02/06/2023]
Abstract
In this work, single Au nanowire electrodes (AuNWEs) were fabricated by laser-assisted pulling/hydrofluoric acid (HF) etching process, which then were characterized by transmission electron microscopy (TEM), electrochemical method and finite-element simulation. The as-prepared single AuNWEs were used to construct electrochemical aptamer-based nanosensors (E-AB nanosensors) based on the formation of Au-S bond that duplex DNA tagged with methylene blue (MB) was modified on the surface of electrode. In the presence of adenosine triphosphate (ATP), the MB-labeled aptamer dissociated from the duplex DNA due to the strong specific affinity between aptamer and target, which lead to the reduction of MB electrochemical signals. Moreover, BSA was employed to further passivate electrode surface bonding sites for the stable of the sensor. The as-prepared E-AB nanosensor has been used for ATP assay with excellent sensitivity and selectivity, even in a complex system like cerebrospinal fluid of rat brain. Considering the unique properties of good stability, larger surface area and smaller overall dimensions, this E-AB nanosensor should be an ideal platform for widely sensing applications in living bio-system.
Collapse
Affiliation(s)
- Dongmei Wang
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, PR China; College of Chemistry and Material Engineering, Chaohu University, Chaohu, Anhui 238000, PR China
| | - Xiaoqing Xiao
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, PR China
| | - Shen Xu
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, PR China
| | - Yong Liu
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, PR China
| | - Yongxin Li
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, PR China.
| |
Collapse
|
34
|
Liu Y, Zhang Y, Hua H, Li Y. Fabrication of single Pt@Au nanowire electrodes for monitoring hydrogen peroxide released from living cells. RSC Adv 2017. [DOI: 10.1039/c7ra08085a] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Single Pt@AuNWEs were fabricated by a Cu UPD/Pt redox replacement technique, and were applied to monitoring H2O2 released from living cells.
Collapse
Affiliation(s)
- Yong Liu
- Anhui Key Laboratory of Chemo/Biosensing
- College of Chemistry and Materials Science
- Anhui Normal University
- Wuhu
- P. R. China
| | - Yaoyao Zhang
- Anhui Key Laboratory of Chemo/Biosensing
- College of Chemistry and Materials Science
- Anhui Normal University
- Wuhu
- P. R. China
| | - Hongmei Hua
- Anhui Key Laboratory of Chemo/Biosensing
- College of Chemistry and Materials Science
- Anhui Normal University
- Wuhu
- P. R. China
| | - Yongxin Li
- Anhui Key Laboratory of Chemo/Biosensing
- College of Chemistry and Materials Science
- Anhui Normal University
- Wuhu
- P. R. China
| |
Collapse
|
35
|
|