Shah DD, Carter P, Shivdasani MN, Fong N, Duan W, Esrafilzadeh D, Poole-Warren LA, Aregueta Robles UA. Deciphering platinum dissolution in neural stimulation electrodes: Electrochemistry or biology? Biomaterials 2024; 309:122575. [PMID: 38677220 DOI: 10.1016/j.biomaterials.2024.122575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/28/2024] [Accepted: 04/13/2024] [Indexed: 04/29/2024]
Abstract
Platinum (Pt) is the metal of choice for electrodes in implantable neural prostheses like the cochlear implants, deep brain stimulating devices, and brain-computer interfacing technologies. However, it is well known since the 1970s that Pt dissolution occurs with electrical stimulation. More recent clinical and in vivo studies have shown signs of corrosion in explanted electrode arrays and the presence of Pt-containing particulates in tissue samples. The process of degradation and release of metallic ions and particles can significantly impact on device performance. Moreover, the effects of Pt dissolution products on tissue health and function are still largely unknown. This is due to the highly complex chemistry underlying the dissolution process and the difficulty in decoupling electrical and chemical effects on biological responses. Understanding the mechanisms and effects of Pt dissolution proves challenging as the dissolution process can be influenced by electrical, chemical, physical, and biological factors, all of them highly variable between experimental settings. By evaluating comprehensive findings on Pt dissolution mechanisms reported in the fuel cell field, this review presents a critical analysis of the possible mechanisms that drive Pt dissolution in neural stimulation in vitro and in vivo. Stimulation parameters, such as aggregate charge, charge density, and electrochemical potential can all impact the levels of dissolved Pt. However, chemical factors such as electrolyte types, dissolved gases, and pH can all influence dissolution, confounding the findings of in vitro studies with multiple variables. Biological factors, such as proteins, have been documented to exhibit a mitigating effect on the dissolution process. Other biological factors like cells and fibro-proliferative responses, such as fibrosis and gliosis, impact on electrode properties and are suspected to impact on Pt dissolution. However, the relationship between electrical properties of stimulating electrodes and Pt dissolution remains contentious. Host responses to Pt degradation products are also controversial due to the unknown chemistry of Pt compounds formed and the lack of understanding of Pt distribution in clinical scenarios. The cytotoxicity of Pt produced via electrical stimulation appears similar to Pt-based compounds, including hexachloroplatinates and chemotherapeutic agents like cisplatin. While the levels of Pt produced under clinical and acute stimulation regimes were typically an order of magnitude lower than toxic concentrations observed in vitro, further research is needed to accurately assess the mass balance and type of Pt produced during long-term stimulation and its impact on tissue response. Finally, approaches to mitigating the dissolution process are reviewed. A wide variety of approaches, including stimulation strategies, coating electrode materials, and surface modification techniques to avoid excess charge during stimulation and minimise tissue response, may ultimately support long-term and safe operation of neural stimulating devices.
Collapse
Affiliation(s)
- Dhyey Devashish Shah
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | - Paul Carter
- Cochlear Ltd, Macquarie University, NSW, Australia
| | | | - Nicole Fong
- Cochlear Ltd, Macquarie University, NSW, Australia
| | - Wenlu Duan
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | - Dorna Esrafilzadeh
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | - Laura Anne Poole-Warren
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia; The Tyree Foundation Institute of Health Engineering, University of New South Wales, Sydney, Australia.
| | | |
Collapse
|
2
|
Lee KK, Celt N, Ardoña HAM. Looking both ways: Electroactive biomaterials with bidirectional implications for dynamic cell-material crosstalk. BIOPHYSICS REVIEWS 2024; 5:021303. [PMID: 38736681 PMCID: PMC11087870 DOI: 10.1063/5.0181222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Accepted: 04/15/2024] [Indexed: 05/14/2024]
Abstract
Cells exist in natural, dynamic microenvironmental niches that facilitate biological responses to external physicochemical cues such as mechanical and electrical stimuli. For excitable cells, exogenous electrical cues are of interest due to their ability to stimulate or regulate cellular behavior via cascade signaling involving ion channels, gap junctions, and integrin receptors across the membrane. In recent years, conductive biomaterials have been demonstrated to influence or record these electrosensitive biological processes whereby the primary design criterion is to achieve seamless cell-material integration. As such, currently available bioelectronic materials are predominantly engineered toward achieving high-performing devices while maintaining the ability to recapitulate the local excitable cell/tissue microenvironment. However, such reports rarely address the dynamic signal coupling or exchange that occurs at the biotic-abiotic interface, as well as the distinction between the ionic transport involved in natural biological process and the electronic (or mixed ionic/electronic) conduction commonly responsible for bioelectronic systems. In this review, we highlight current literature reports that offer platforms capable of bidirectional signal exchange at the biotic-abiotic interface with excitable cell types, along with the design criteria for such biomaterials. Furthermore, insights on current materials not yet explored for biointerfacing or bioelectronics that have potential for bidirectional applications are also provided. Finally, we offer perspectives aimed at bringing attention to the coupling of the signals delivered by synthetic material to natural biological conduction mechanisms, areas of improvement regarding characterizing biotic-abiotic crosstalk, as well as the dynamic nature of this exchange, to be taken into consideration for material/device design consideration for next-generation bioelectronic systems.
Collapse
Affiliation(s)
- Kathryn Kwangja Lee
- Department of Chemical and Biomolecular Engineering, University of California, Irvine, California 92697, USA
| | - Natalie Celt
- Department of Biomedical Engineering, University of California, Irvine, California 92697, USA
| | | |
Collapse
|
3
|
Jamali SS, Somerville SV, Dief EM, Gooding JJ. Stochastic Electrochemical Measurement of a Biofouling Layer on Gold. Anal Chem 2024; 96:7401-7410. [PMID: 38702865 DOI: 10.1021/acs.analchem.3c04868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2024]
Abstract
Adsorption of a biofouling layer on the surface of biosensors decreases the electrochemical activity and hence shortens the service life of biosensors, particularly implantable and wearable biosensors. Real-time quantification of the loss of activity is important for in situ assessment of performance while presenting an opportunity to compensate for the loss of activity and recalibrate the sensor to extend the service life. Here, we introduce an electrochemical noise measurement technique as a tool for the quantification of the formation of a biofouling layer on the surface of gold. The technique uniquely affords thermodynamic and kinetic information without applying an external bias (potential and/or current), hence allowing the system to be appraised in its innate state. The technique relies on the analysis of non-faradaic current and potential fluctuations that are intrinsically generated by the interaction of charged species at the electrode surface, i.e., gold. An analytical model is extended to explain the significance of parameters drawn from statistical analysis of the noise signal. This concept is then examined in buffered media in the presence of albumin, a common protein in the blood and a known source of a fouling layer in biological systems. Results indicate that the statistical analysis of the noise signal can quantify the loss of electrochemical activity, which is also corroborated by impedance spectroscopy as a complementary technique.
Collapse
Affiliation(s)
- Sina S Jamali
- Queensland Micro- and Nanotechnology Centre, School of Environment and Science, Griffith University, Nathan, QLD 4111 Australia
| | - Samuel V Somerville
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney 2052, Australia
| | - Essam M Dief
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney 2052, Australia
| | - J Justin Gooding
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney 2052, Australia
| |
Collapse
|
4
|
Harris AR. Limitations in the electrochemical analysis of voltage transients. J Neural Eng 2024; 21:013003. [PMID: 38215494 DOI: 10.1088/1741-2552/ad1e23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 01/12/2024] [Indexed: 01/14/2024]
Abstract
Objective. Chronopotentiometric voltage transients (VTs) are used to assess the performance of bionic electrodes. The data obtained from VTs are used to define the safe operating conditions of clinical devices. Various approaches to analysing VTs have been reported, and a number of limitations in the accuracy of the measurements in relation to electrode size have been noted previously.Approach. The impact of electronic hardware and electrode configuration on VTs is discussed.Main results. The slew rate, rise time, sample time, minimum pulse length and waveform averaging characteristics of the electronic hardware, and electrode configuration will impact on VT measurement accuracy. Subsequently, activation and polarisation voltage measurements, and the definition of safe stimulation levels can be affected by the electronic hardware and electrode configuration.Significance. This article has identified some limitations in the previous literature related to the measurement and reporting of VTs and subsequent analysis of access and polarisation voltages. Furthermore, the commonly used Shannon plot used to define safe stimulation protocols does not correct for uncompensated resistance, account for electrode roughness or changes in electrode configuration. The creation of a safe stimulation plot which has been corrected for uncompensated resistance would generate more widely applicable stimulation guidelines for clinical devices used in different anatomical locations such as endovascular neural interfaces.
Collapse
Affiliation(s)
- Alexander R Harris
- Department of Biomedical Engineering, University of Melbourne, Melbourne 3010, Australia
| |
Collapse
|
5
|
Cremin K, Meloni GN, Valavanis D, Soyer OS, Unwin PR. Can Single Cell Respiration be Measured by Scanning Electrochemical Microscopy (SECM)? ACS MEASUREMENT SCIENCE AU 2023; 3:361-370. [PMID: 37868362 PMCID: PMC10588932 DOI: 10.1021/acsmeasuresciau.3c00019] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 06/13/2023] [Accepted: 06/13/2023] [Indexed: 10/24/2023]
Abstract
Ultramicroelectrode (UME), or, equivalently, microelectrode, probes are increasingly used for single-cell measurements of cellular properties and processes, including physiological activity, such as metabolic fluxes and respiration rates. Major challenges for the sensitivity of such measurements include: (i) the relative magnitude of cellular and UME fluxes (manifested in the current); and (ii) issues around the stability of the UME response over time. To explore the extent to which these factors impact the precision of electrochemical cellular measurements, we undertake a systematic analysis of measurement conditions and experimental parameters for determining single cell respiration rates via the oxygen consumption rate (OCR) in single HeLa cells. Using scanning electrochemical microscopy (SECM), with a platinum UME as the probe, we employ a self-referencing measurement protocol, rarely employed in SECM, whereby the UME is repeatedly approached from bulk solution to a cell, and a short pulse to oxygen reduction reaction (ORR) potential is performed near the cell and in bulk solution. This approach enables the periodic tracking of the bulk UME response to which the near-cell response is repeatedly compared (referenced) and also ensures that the ORR near the cell is performed only briefly, minimizing the effect of the electrochemical process on the cell. SECM experiments are combined with a finite element method (FEM) modeling framework to simulate oxygen diffusion and the UME response. Taking a realistic range of single cell OCR to be 1 × 10-18 to 1 × 10-16 mol s-1, results from the combination of FEM simulations and self-referencing SECM measurements show that these OCR values are at, or below, the present detection sensitivity of the technique. We provide a set of model-based suggestions for improving these measurements in the future but highlight that extraordinary improvements in the stability and precision of SECM measurements will be required if single cell OCR measurements are to be realized.
Collapse
Affiliation(s)
- Kelsey Cremin
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Gabriel N. Meloni
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Dimitrios Valavanis
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Orkun S. Soyer
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
6
|
Wellens J, Deschaume O, Putzeys T, Eyley S, Thielemans W, Verhaert N, Bartic C. Sulfobetaine-based ultrathin coatings as effective antifouling layers for implantable neuroprosthetic devices. Biosens Bioelectron 2023; 226:115121. [PMID: 36774733 DOI: 10.1016/j.bios.2023.115121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 01/30/2023] [Accepted: 02/02/2023] [Indexed: 02/05/2023]
Abstract
Foreign body response (FBR), inflammation, and fibrotic encapsulation of neural implants remain major problems affecting the impedance of the electrode-tissue interface and altering the device performance. Adhesion of proteins and cells (e.g., pro-inflammatory macrophages, and fibroblasts) triggers the FBR cascade and can be diminished by applying antifouling coatings onto the implanted devices. In this paper, we report the deposition and characterization of a thin (±6 nm) sulfobetaine-based coating onto microfabricated platinum electrodes and cochlear implant (CI) electrode arrays. We found that this coating has stable cell and protein-repellent properties, for at least 31 days in vitro, not affected by electrical stimulation protocols. Additionally, its effect on the electrochemical properties relevant to stimulation (i.e., impedance, charge injection capacity) was negligible. When applied to clinical CI electrode arrays, the film was successful at inhibiting fibroblast adhesion on both the silicone packaging and the platinum/iridium electrodes. In vitro, in fibroblast cultures, coated CI electrode arrays maintained impedance values up to five times lower compared to non-coated devices. Our studies demonstrate that such thin sulfobetaine containing layers are stable and prevent protein and cell adhesion in vitro and are compatible for use on CI electrode arrays. Future in vivo studies should be conducted to investigate its ability to mitigate biofouling, fibrosis, and the resulting impedance changes upon long-term implantation in vivo.
Collapse
Affiliation(s)
- Jolan Wellens
- Laboratory for Soft Matter and Biophysics, Dept. Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, 3001, Leuven, Belgium
| | - Olivier Deschaume
- Laboratory for Soft Matter and Biophysics, Dept. Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, 3001, Leuven, Belgium
| | - Tristan Putzeys
- Laboratory for Soft Matter and Biophysics, Dept. Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, 3001, Leuven, Belgium; Experimental Oto-rhino-laryngology Research Group, Dept. Neuroscience, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Samuel Eyley
- Sustainable Materials Lab, Department of Chemical Engineering, KU Leuven, Campus Kulak Kortrijk, Etienne Sabbelaan 53, 8500, Kortrijk, Belgium
| | - Wim Thielemans
- Sustainable Materials Lab, Department of Chemical Engineering, KU Leuven, Campus Kulak Kortrijk, Etienne Sabbelaan 53, 8500, Kortrijk, Belgium
| | - Nicolas Verhaert
- Experimental Oto-rhino-laryngology Research Group, Dept. Neuroscience, KU Leuven, Herestraat 49, 3000, Leuven, Belgium; Department of Otorhinolaryngology, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Carmen Bartic
- Laboratory for Soft Matter and Biophysics, Dept. Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, 3001, Leuven, Belgium.
| |
Collapse
|
7
|
Wu W, Deng Y, Chen G. A self-repairing polymer-inorganic composite coating to enable high-performance Zn anodes for zinc-ion batteries. CHINESE CHEM LETT 2023. [DOI: 10.1016/j.cclet.2023.108424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
|
8
|
Harris AR, Grayden DB, John SE. Electrochemistry in a Two- or Three-Electrode Configuration to Understand Monopolar or Bipolar Configurations of Platinum Bionic Implants. MICROMACHINES 2023; 14:722. [PMID: 37420955 DOI: 10.3390/mi14040722] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 03/21/2023] [Accepted: 03/22/2023] [Indexed: 07/09/2023]
Abstract
Electrodes are used in vivo for chemical sensing, electrophysiological recording, and stimulation of tissue. The electrode configuration used in vivo is often optimised for a specific anatomy and biological or clinical outcomes, not electrochemical performance. Electrode materials and geometries are constrained by biostability and biocompatibility issues and may be required to function clinically for decades. We performed benchtop electrochemistry, with changes in reference electrode, smaller counter-electrode sizes, and three- or two-electrode configurations. We detail the effects different electrode configurations have on typical electroanalytical techniques used on implanted electrodes. Changes in reference electrode required correction by application of an offset potential. In a two-electrode configuration with similar working and reference/counter-electrode sizes, the electrochemical response was dictated by the rate-limiting charge transfer step at either electrode. This could invalidate calibration curves, standard analytical methods, and equations, and prevent use of commercial simulation software. We provide methods for determining if an electrode configuration is affecting the in vivo electrochemical response. We recommend sufficient details be provided in experimental sections on electronics, electrode configuration, and their calibration to justify results and discussion. In conclusion, the experimental limitations of performing in vivo electrochemistry may dictate what types of measurements and analyses are possible, such as obtaining relative rather than absolute measurements.
Collapse
Affiliation(s)
- Alexander R Harris
- Department of Biomedical Engineering, University of Melbourne, Melbourne 3010, Australia
| | - David B Grayden
- Department of Biomedical Engineering, University of Melbourne, Melbourne 3010, Australia
- Graeme Clark Institute, University of Melbourne, Melbourne 3010, Australia
| | - Sam E John
- Department of Biomedical Engineering, University of Melbourne, Melbourne 3010, Australia
| |
Collapse
|
9
|
Butler D, Kammarchedu V, Zhou K, Peeke L, Lyle L, Snyder DW, Ebrahimi A. Cellulose-Based Laser-Induced Graphene Devices for Electrochemical Monitoring of Bacterial Phenazine Production and Viability. SENSORS AND ACTUATORS. B, CHEMICAL 2023; 378:133090. [PMID: 36644326 PMCID: PMC9835725 DOI: 10.1016/j.snb.2022.133090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
As an easily disposable substrate with a microporous texture, paper is a well-suited, generic substrate to build analytical devices for studying bacteria. Using a multi-pass lasing process, cellulose-based laser-induced graphene (cLIG) with a sheet resistance of 43.7 ± 2.3 Ωsq-1 is developed and utilized in the fabrication of low-cost and environmentally-friendly paper sensor arrays. Two case studies with Pseudomonas aeruginosa and Escherichia coli demonstrate the practicality of the cLIG sensors for the electrochemical analysis of bacteria. The first study measures the time-dependent profile of phenazines released from both planktonic (up to 60 h) and on-chip-grown (up to 22 h) Pseudomonas aeruginosa cultures. While similarities do exist, marked differences in phenazine production are seen with cells grown directly on cLIG compared to the planktonic culture. Moreover, in planktonic cultures, pyocyanin levels increase early on and plateau around 20 h, while optical density measurements increase monotonically over the duration of testing. The second study monitors the viability and metabolic activity of Escherichia coli using a resazurin-based electrochemical assay. These results demonstrate the utility of cLIG paper sensors as an inexpensive and versatile platform for monitoring bacteria and could enable new opportunities in high-throughput antibiotic susceptibility testing, ecological studies, and biofilm studies.
Collapse
Affiliation(s)
- Derrick Butler
- Department of Electrical Engineering, The Pennsylvania State University, University Park, PA 16802
- Center for Atomically Thin Multifunctional Coatings, The Pennsylvania State University, University Park, PA 16802
| | - Vinay Kammarchedu
- Department of Electrical Engineering, The Pennsylvania State University, University Park, PA 16802
- Center for Atomically Thin Multifunctional Coatings, The Pennsylvania State University, University Park, PA 16802
- Center for Biodevices, The Pennsylvania State University, University Park, PA 16802
| | - Keren Zhou
- Department of Electrical Engineering, The Pennsylvania State University, University Park, PA 16802
| | - Lachlan Peeke
- Applied Research Laboratory - Electronic Materials and Devices Department, The Pennsylvania State University, University Park, PA 16802
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA 16802
| | - Luke Lyle
- Applied Research Laboratory - Electronic Materials and Devices Department, The Pennsylvania State University, University Park, PA 16802
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA 16802
| | - David W Snyder
- Applied Research Laboratory - Electronic Materials and Devices Department, The Pennsylvania State University, University Park, PA 16802
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA 16802
- Department of Chemical Engineering, The Pennsylvania State University, University Park, PA 16802
| | - Aida Ebrahimi
- Department of Electrical Engineering, The Pennsylvania State University, University Park, PA 16802
- Center for Atomically Thin Multifunctional Coatings, The Pennsylvania State University, University Park, PA 16802
- Center for Biodevices, The Pennsylvania State University, University Park, PA 16802
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802
| |
Collapse
|
10
|
Evers J, Sridhar K, Liegey J, Brady J, Jahns H, Lowery M. Stimulation-induced changes at the electrode-tissue interface and their influence on deep brain stimulation. J Neural Eng 2022; 19. [PMID: 35728575 DOI: 10.1088/1741-2552/ac7ad6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 06/21/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE During deep brain stimulation (DBS) the electrode-tissue interface forms a critical path between device and brain tissue. Although changes in the electrical double layer and glial scar can impact stimulation efficacy, the effects of chronic DBS on the electrode-tissue interface have not yet been established. APPROACH In this study, we characterised the electrode-tissue interface surrounding chronically implanted DBS electrodes in rats and compared the impedance and histological properties at the electrode interface in animals that received daily stimulation and in those where no stimulation was applied, up to eight weeks post-surgery. A computational model was developed based on the experimental data, which allowed the dispersive electrical properties of the surrounding encapsulation tissue to be estimated. The model was then used to study the effect of stimulation-induced changes in the electrode-tissue interface on the electric field and neural activation during voltage- and current-controlled stimulation. MAIN RESULTS Incorporating the observed changes in simulations in silico, we estimated the frequency-dependent dielectric properties of the electrical double layer and surrounding encapsulation tissue. Through simulations we show how stimulation-induced changes in the properties of the electrode-tissue interface influence the electric field and alter neural activation during voltage-controlled stimulation. A substantial increase in the number of stimulated collaterals, and their distance from the electrode, was observed during voltage-controlled stimulation with stimulated ETI properties. In vitro examination of stimulated electrodes confirmed that high frequency stimulation leads to desorption of proteins at the electrode interface, with a concomitant reduction in impedance. SIGNIFICANCE The demonstration of stimulation-induced changes in the electrode-tissue interface has important implications for future DBS systems including closed-loop systems where the applied stimulation may change over time. Understanding these changes is particularly important for systems incorporating simultaneous stimulation and sensing, which interact dynamically with brain networks.
Collapse
Affiliation(s)
- J Evers
- School of Electrical and Electronic Engineering, University College Dublin, Engineering Building, UCD Belfield, Dublin, Dublin, 4, IRELAND
| | - K Sridhar
- School of Electrical and Electronic Engineering, University College Dublin, Engineering Building, UCD Belfield, Dublin, Dublin, 4, IRELAND
| | - J Liegey
- School of Electrical and Electronic Engineering, University College Dublin, Engineering Building, UCD Belfield, Dublin, Dublin, 4, IRELAND
| | - J Brady
- School of Veterinary Medicine, University College Dublin, Veterinary Science Center, Dublin, 4, IRELAND
| | - H Jahns
- School of Veterinary Medicine, University College Dublin, Veterinary Science Center, Dublin, 4, IRELAND
| | - M Lowery
- School of Electrical, Electronic & Mechancial Engineering, University College Dublin, Engineering & Materials Science Centre, Belfield, Dublin 4, Dublin, 4, IRELAND
| |
Collapse
|
11
|
Lee S, Park J, Kim S, Ok J, Yoo JI, Kim YS, Ahn Y, Kim TI, Ko HC, Lee JY. High-Performance Implantable Bioelectrodes with Immunocompatible Topography for Modulation of Macrophage Responses. ACS NANO 2022; 16:7471-7485. [PMID: 35438981 DOI: 10.1021/acsnano.1c10506] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Implantable bioelectrodes enable precise recording or stimulation of electrical signals with living tissues in close contact. However, their performance is frequently compromised owing to inflammatory tissue reactions, which macrophages either induce or resolve by polarizing to an inflammatory (M1) or noninflammatory (M2) phenotype, respectively. Thus, we aimed to fabricate biocompatible and functional implantable conductive polymer bioelectrodes with optimal topography for the modulation of macrophage responses. To this end, we produced heparin-doped polypyrrole (PPy/Hep) electrodes of different surface roughness, with Ra values from 5.5 to 17.6 nm, by varying the charge densities during electrochemical synthesis. In vitro culture revealed that macrophages on rough PPy/Hep electrodes preferentially polarized to noninflammatory phenotypes. In particular, PPy/Hep-900 (Ra = 14 nm) was optimal with respect to electrochemical properties and the suppression of inflammatory M1 polarization. In vivo implantation indicated that PPy/Hep-900 significantly reduced macrophage recruitment, suppressed inflammatory polarization, and mitigated fibrotic tissue formation. In addition, the implanted PPy/Hep-900 electrodes could successfully record electrocardiographic signals for up to 10 days without substantial decreases in sensitivity, while other electrodes substantially lost their signal sensitivity during implantation. Altogether, we demonstrate that modulating the surface features of PPy/Hep can benefit the design and applications of high-performance and high-biocompatibility bioelectrodes.
Collapse
Affiliation(s)
- Sanghun Lee
- School of Materials Science and Engineering, Gwangju Institute of Science and Technology, Gwangju, 61005, Republic of Korea
| | - Junggeon Park
- School of Materials Science and Engineering, Gwangju Institute of Science and Technology, Gwangju, 61005, Republic of Korea
| | - Semin Kim
- School of Materials Science and Engineering, Gwangju Institute of Science and Technology, Gwangju, 61005, Republic of Korea
| | - Jehyung Ok
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Jung Il Yoo
- School of Materials Science and Engineering, Gwangju Institute of Science and Technology, Gwangju, 61005, Republic of Korea
| | - Yong Sook Kim
- Biomedical Research Institute, Chonnam National University Hospital, Gwangju, 61469, Republic of Korea
- Cell Regeneration Research Center, Chonnam National University Hospital, Gwangju, 61469, Republic of Korea
| | - Youngkeun Ahn
- Biomedical Research Institute, Chonnam National University Hospital, Gwangju, 61469, Republic of Korea
- Cell Regeneration Research Center, Chonnam National University Hospital, Gwangju, 61469, Republic of Korea
| | - Tae-Il Kim
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Heung Cho Ko
- School of Materials Science and Engineering, Gwangju Institute of Science and Technology, Gwangju, 61005, Republic of Korea
| | - Jae Young Lee
- School of Materials Science and Engineering, Gwangju Institute of Science and Technology, Gwangju, 61005, Republic of Korea
| |
Collapse
|
12
|
Comparison of the In Vitro and In Vivo Electrochemical Performance of Bionic Electrodes. MICROMACHINES 2022; 13:mi13010103. [PMID: 35056268 PMCID: PMC8779563 DOI: 10.3390/mi13010103] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 12/14/2021] [Accepted: 01/04/2022] [Indexed: 12/13/2022]
Abstract
The electrochemical performance of platinum electrodes was assessed in vitro and in vivo to determine the impact of electrode implantation and the relevance of in vitro testing in predicting in vivo behaviour. A significant change in electrochemical response was seen after electrode polarisation. As a result, initial in vitro measurements were poor predictors of subsequent measurements performed in vitro or in vivo. Charge storage capacity and charge density measurements from initial voltammetric measurements were not correlated with subsequent measurements. Electrode implantation also affected the electrochemical impedance. The typically reported impedance at 1 kHz was a very poor predictor of electrode performance. Lower frequencies were significantly more dependent on electrode properties, while higher frequencies were dependent on solution properties. Stronger correlations in impedance at low frequencies were seen between in vitro and in vivo measurements after electrode activation had occurred. Implanting the electrode increased the resistance of the electrochemical circuit, with bone having a higher resistivity than soft tissue. In contrast, protein fouling and fibrous tissue formation had a minimal impact on electrochemical response. In vivo electrochemical measurements also typically use a quasi-reference electrode, may operate in a 2-electrode system, and suffer from uncompensated resistance. The impact of these experimental conditions on electrochemical performance and the relevance of in vitro electrode assessment is discussed. Recommended in vitro testing protocols for assessing bionic electrodes are presented.
Collapse
|
13
|
Sadok I, Staniszewska M. Electrochemical Determination of Kynurenine Pathway Metabolites-Challenges and Perspectives. SENSORS (BASEL, SWITZERLAND) 2021; 21:7152. [PMID: 34770460 PMCID: PMC8588338 DOI: 10.3390/s21217152] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 10/22/2021] [Accepted: 10/24/2021] [Indexed: 12/23/2022]
Abstract
In recent years, tryptophan metabolism via the kynurenine pathway has become one of the most active research areas thanks to its involvement in a variety of physiological processes, especially in conditions associated with immune dysfunction, central nervous system disorders, autoimmunity, infection, diabetes, and cancer. The kynurenine pathway generates several metabolites with immunosuppressive functions or neuroprotective, antioxidant, or toxic properties. An increasing body of work on this topic uncovers a need for reliable analytical methods to help identify and quantify tryptophan metabolites at physiological concentrations in biological samples of different origins. Recent methodological advances in the fabrication and application of electrochemical sensors promise a rise in the future generation of novel analytical systems. This work summarizes current knowledge and provides important suggestions with respect to direct electrochemical determinations of kynurenine pathway metabolites (kynurenines) in complex biological matrices. Measurement challenges, limitations, and future opportunities of electroanalytical methods to advance study of the implementation of kynurenines in disease conditions are discussed.
Collapse
Affiliation(s)
- Ilona Sadok
- Laboratory of Separation and Spectroscopic Method Applications, Centre for Interdisciplinary Research, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland;
| | | |
Collapse
|
14
|
Fibrinogen, collagen, and transferrin adsorption to poly(3,4-ethylenedioxythiophene)-xylorhamno-uronic glycan composite conducting polymer biomaterials for wound healing applications. Biointerphases 2021; 16:021003. [PMID: 33752337 DOI: 10.1116/6.0000708] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
We present the conducting polymer poly (3,4-ethylenedioxythiophene) (PEDOT) doped with an algal-derived glycan extract, Phycotrix™ [xylorhamno-uronic glycan (XRU84)], as an innovative electrically conductive material capable of providing beneficial biological and electrical cues for the promotion of favorable wound healing processes. Increased loading of the algal XRU84 into PEDOT resulted in a reduced surface nanoroughness and interfacial surface area and an increased static water contact angle. PEDOT-XRU84 films demonstrated good electrical stability and charge storage capacity and a reduced impedance relative to the control gold electrode. A quartz crystal microbalance with dissipation monitoring study of protein adsorption (transferrin, fibrinogen, and collagen) showed that collagen adsorption increased significantly with increased XRU84 loading, while transferrin adsorption was significantly reduced. The viscoelastic properties of adsorbed protein, characterized using the ΔD/Δf ratio, showed that for transferrin and fibrinogen, a rigid, dehydrated layer was formed at low XRU84 loadings. Cell studies using human dermal fibroblasts demonstrated excellent cell viability, with fluorescent staining of the cell cytoskeleton illustrating all polymers to present excellent cell adhesion and spreading after 24 h.
Collapse
|