1
|
Walia A, Shew MA, Varghese J, Lefler SM, Bhat A, Ortmann AJ, Herzog JA, Buchman CA. Electrocochleography-Based Tonotopic Map: II. Frequency-to-Place Mismatch Impacts Speech-Perception Outcomes in Cochlear Implant Recipients. Ear Hear 2024:00003446-990000000-00298. [PMID: 38880958 DOI: 10.1097/aud.0000000000001528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/18/2024]
Abstract
OBJECTIVES Modern cochlear implants (CIs) use varying-length electrode arrays inserted at varying insertion angles within variably sized cochleae. Thus, there exists an opportunity to enhance CI performance, particularly in postlinguistic adults, by optimizing the frequency-to-place allocation for electrical stimulation, thereby minimizing the need for central adaptation and plasticity. There has been interest in applying Greenwood or Stakhovskaya et al. function (describing the tonotopic map) to postoperative imaging of electrodes to improve frequency allocation and place coding. Acoustically-evoked electrocochleography (ECochG) allows for electrophysiologic best-frequency (BF) determination of CI electrodes and the potential for creating a personalized frequency allocation function. The objective of this study was to investigate the correlation between early speech-perception performance and frequency-to-place mismatch. DESIGN This retrospective study included 50 patients who received a slim perimodiolar electrode array. Following electrode insertion, five acoustic pure-tone stimuli ranging from 0.25 to 2 kHz were presented, and electrophysiological measurements were collected across all 22 electrode contacts. Cochlear microphonic tuning curves were subsequently generated for each stimulus frequency to ascertain the BF electrode or the location corresponding to the maximum response amplitude. Subsequently, we calculated the difference between the stimulus frequency and the patient's CI map's actual frequency allocation at each BF electrode, reflecting the frequency-to-place mismatch. BF electrocochleography-total response (BF-ECochG-TR), a measure of cochlear health, was also evaluated for each subject to control for the known impact of this measure on performance. RESULTS Our findings showed a moderate correlation (r = 0.51; 95% confidence interval: 0.23 to 0.76) between the cumulative frequency-to-place mismatch, as determined using the ECochG-derived BF map (utilizing 500, 1000, and 2000 Hz), and 3-month performance on consonant-nucleus-consonant words (N = 38). Larger positive mismatches, shifted basal from the BF map, led to enhanced speech perception. Incorporating BF-ECochG-TR, total mismatch, and their interaction in a multivariate model explained 62% of the variance in consonant-nucleus-consonant word scores at 3 months. BF-ECochG-TR as a standalone predictor tended to overestimate performance for subjects with larger negative total mismatches and underestimated the performance for those with larger positive total mismatches. Neither cochlear diameter, number of cochlear turns, nor apical insertion angle accounted for the variability in total mismatch. CONCLUSIONS Comparison of ECochG-BF derived tonotopic electrode maps to the frequency allocation tables reveals substantial mismatch, explaining 26.0% of the variability in CI performance in quiet. Closer examination of the mismatch shows that basally shifted maps at high frequencies demonstrate superior performance at 3 months compared with those with apically shifted maps (toward Greenwood and Stakhovskaya et al.). The implications of these results suggest that electrophysiological-based frequency reallocation might lead to enhanced speech-perception performance, especially when compared with conventional manufacturer maps or anatomic-based mapping strategies. Future research, exploring the prospective use of ECochG-based mapping techniques for frequency allocation is underway.
Collapse
Affiliation(s)
- Amit Walia
- Department of Otolaryngology-Head and Neck Surgery, Washington University School of Medicine in St. Louis, St Louis, Missouri, USA
| | | | | | | | | | | | | | | |
Collapse
|
2
|
Gerlitz M, Yildiz E, Gadenstaetter AJ, Niisuke K, Kandathil SA, Nieratschker M, Landegger LD, Honeder C, Arnoldner C. Insertion trauma of a novel inner ear catheter for intracochlear drug delivery. Front Vet Sci 2024; 11:1397554. [PMID: 38903692 PMCID: PMC11188737 DOI: 10.3389/fvets.2024.1397554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Accepted: 05/15/2024] [Indexed: 06/22/2024] Open
Abstract
Introduction Even with recent research advances, effective delivery of a compound to its target cells inside the inner ear remains a challenging endeavor due to anatomical and physiological barriers. Direct intracochlear drug administration with an inner ear catheter (IEC) aims to overcome this obstacle and strives to provide a safe and efficient way for inner ear pharmacotherapy. The goal of this study was to histologically and audiologically evaluate the traumatic properties of a novel IEC for intracochlear drug delivery in a large animal model. Methods Seven inner ears of piglets that had undergone intracochlear fluorescein isothiocyanate dextran application via an IEC (n = 4) or round window membrane (RWM) puncture with a needle (n = 3) followed by sequential apical perilymph sampling were histologically analyzed. Additionally, obtained objective auditory compound action potential and cochlear microphonic measurements were compared. Cochlear cryosections were stained using hematoxylin and eosin, and preservation of inner ear structures was investigated. Moreover, one cochlea was methylmethacrylate-embedded and analyzed with the IEC in situ. Results Histological evaluation revealed an atraumatic insertion and subsequent compound application in a majority of IEC-inserted inner ears. Click cochlear compound action potential (CAP) shifts in the IEC groups reached a maximum of 5 dB (1.25 ± 2.5 dB) post administration and prior to perilymph sampling. In comparison, application by RWM puncture generated a maximum click CAP hearing threshold shift of 50 dB (23.3 ± 23.1 dB) coinciding with coagulated blood in the basal cochlear turn in one specimen of the latter group. Furthermore, in situ histology showed an atraumatic insertion of the IEC demonstrating preserved intracochlear structures. Conclusion The IEC appears to be a promising and efficient way for inner ear drug delivery. The similarities between the porcine and human inner ear enhance the clinical translation of our findings and increase confidence regarding the safe applicability of the IEC in human subjects.
Collapse
Affiliation(s)
- Matthias Gerlitz
- Department of Otorhinolaryngology, Head and Neck Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Inner Ear Research, Department of Otorhinolaryngology, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Erdem Yildiz
- Department of Otorhinolaryngology, Head and Neck Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Inner Ear Research, Department of Otorhinolaryngology, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Anselm J. Gadenstaetter
- Department of Otorhinolaryngology, Head and Neck Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Inner Ear Research, Department of Otorhinolaryngology, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Katrin Niisuke
- Christian Doppler Laboratory for Inner Ear Research, Department of Otorhinolaryngology, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Sam A. Kandathil
- Department of Otorhinolaryngology, Head and Neck Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
- Division of Anatomy, Center for Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria
| | - Michael Nieratschker
- Department of Otorhinolaryngology, Head and Neck Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Inner Ear Research, Department of Otorhinolaryngology, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Lukas D. Landegger
- Department of Otorhinolaryngology, Head and Neck Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Inner Ear Research, Department of Otorhinolaryngology, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Clemens Honeder
- Department of Otorhinolaryngology, Head and Neck Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Inner Ear Research, Department of Otorhinolaryngology, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Christoph Arnoldner
- Department of Otorhinolaryngology, Head and Neck Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Inner Ear Research, Department of Otorhinolaryngology, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
3
|
Micuda A, Li H, Rask-Andersen H, Ladak HM, Agrawal SK. Morphologic Analysis of the Scala Tympani Using Synchrotron: Implications for Cochlear Implantation. Laryngoscope 2024; 134:2889-2897. [PMID: 38189807 DOI: 10.1002/lary.31263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 12/04/2023] [Accepted: 12/20/2023] [Indexed: 01/09/2024]
Abstract
OBJECTIVES To use synchrotron radiation phase-contrast imaging (SR-PCI) to visualize and measure the morphology of the entire cochlear scala tympani (ST) and assess cochlear implant (CI) electrode trajectories. METHODS SR-PCI images were used to obtain geometric measurements of the cochlear scalar diameter and area at 5-degree increments in 35 unimplanted and three implanted fixed human cadaveric cochleae. RESULTS The cross-sectional diameter and area of the cochlea were found to decrease from the base to the apex. This study represents a wide variability in cochlear morphology and suggests that even in the smallest cochlea, the ST can accommodate a 0.4 mm diameter electrode up to 720°. Additionally, all lateral wall array trajectories were within the anatomically accommodating insertion zone. CONCLUSION This is the first study to use SR-PCI to visualize and quantify the entire ST morphology, from the round window to the apical tip, and assess the post-operative trajectory of electrodes. These high-resolution anatomical measurements can be used to inform the angular insertion depth that can be accommodated in CI patients, accounting for anatomical variability. LEVEL OF EVIDENCE N/A. Laryngoscope, 134:2889-2897, 2024.
Collapse
Affiliation(s)
- Ashley Micuda
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Hao Li
- Department of Surgical Sciences, Otorhinolaryngology and Head and Neck Surgery, Uppsala University, Uppsala, Sweden
| | - Helge Rask-Andersen
- Department of Surgical Sciences, Otorhinolaryngology and Head and Neck Surgery, Uppsala University, Uppsala, Sweden
| | - Hanif M Ladak
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- School of Biomedical Engineering, Western University, London, Ontario, Canada
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Ontario, Canada
- Department of Electrical and Computer Engineering, Western University, London, Ontario, Canada
| | - Sumit K Agrawal
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- School of Biomedical Engineering, Western University, London, Ontario, Canada
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Ontario, Canada
- Department of Electrical and Computer Engineering, Western University, London, Ontario, Canada
| |
Collapse
|
4
|
Adenis V, Partouche E, Stahl P, Gnansia D, Huetz C, Edeline JM. Asymmetric pulses delivered by a cochlear implant allow a reduction in evoked firing rate and in spatial activation in the guinea pig auditory cortex. Hear Res 2024; 447:109027. [PMID: 38723386 DOI: 10.1016/j.heares.2024.109027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 04/30/2024] [Accepted: 05/02/2024] [Indexed: 05/25/2024]
Abstract
Despite that fact that the cochlear implant (CI) is one of the most successful neuro-prosthetic devices which allows hearing restoration, several aspects still need to be improved. Interactions between stimulating electrodes through current spread occurring within the cochlea drastically limit the number of discriminable frequency channels and thus can ultimately result in poor speech perception. One potential solution relies on the use of new pulse shapes, such as asymmetric pulses, which can potentially reduce the current spread within the cochlea. The present study characterized the impact of changing electrical pulse shapes from the standard biphasic symmetric to the asymmetrical shape by quantifying the evoked firing rate and the spatial activation in the guinea pig primary auditory cortex (A1). At a fixed charge, the firing rate and the spatial activation in A1 decreased by 15 to 25 % when asymmetric pulses were used to activate the auditory nerve fibers, suggesting a potential reduction of the spread of excitation inside the cochlea. A strong "polarity-order" effect was found as the reduction was more pronounced when the first phase of the pulse was cathodic with high amplitude. These results suggest that the use of asymmetrical pulse shapes in clinical settings can potentially reduce the channel interactions in CI users.
Collapse
Affiliation(s)
- V Adenis
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - E Partouche
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - P Stahl
- Oticon Medical, Vallauris, France
| | | | - C Huetz
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - J-M Edeline
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France.
| |
Collapse
|
5
|
Athanasopoulos M, Samara P, Athanasopoulos I. Advances in 3D Inner Ear Reconstruction Software for Cochlear Implants: A Comprehensive Review. Methods Protoc 2024; 7:46. [PMID: 38921825 PMCID: PMC11207030 DOI: 10.3390/mps7030046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 05/15/2024] [Accepted: 05/21/2024] [Indexed: 06/27/2024] Open
Abstract
Auditory impairment stands as a pervasive global issue, exerting significant effects on individuals' daily functioning and interpersonal engagements. Cochlear implants (CIs) have risen as a cutting-edge solution for severe to profound hearing loss, directly stimulating the auditory nerve with electrical signals. The success of CI procedures hinges on precise pre-operative planning and post-operative evaluation, highlighting the significance of advanced three-dimensional (3D) inner ear reconstruction software. Accurate pre-operative imaging is vital for identifying anatomical landmarks and assessing cochlear deformities. Tools like 3D Slicer, Amira and OTOPLAN provide detailed depictions of cochlear anatomy, aiding surgeons in simulating implantation scenarios and refining surgical approaches. Post-operative scans play a crucial role in detecting complications and ensuring CI longevity. Despite technological advancements, challenges such as standardization and optimization persist. This review explores the role of 3D inner ear reconstruction software in patient selection, surgical planning, and post-operative assessment, tracing its evolution and emphasizing features like image segmentation and virtual simulation. It addresses software limitations and proposes solutions, advocating for their integration into clinical practice. Ultimately, this review underscores the impact of 3D inner ear reconstruction software on cochlear implantation, connecting innovation with precision medicine.
Collapse
Affiliation(s)
- Michail Athanasopoulos
- Otolaryngology-Head & Neck Surgery, Athens Pediatric Center, 15125 Athens, Greece; (M.A.); (I.A.)
| | - Pinelopi Samara
- Children’s Oncology Unit “Marianna V. Vardinoyannis-ELPIDA”, Aghia Sophia Children’s Hospital, 11527 Athens, Greece
| | - Ioannis Athanasopoulos
- Otolaryngology-Head & Neck Surgery, Athens Pediatric Center, 15125 Athens, Greece; (M.A.); (I.A.)
| |
Collapse
|
6
|
Sriperumbudur KK, Appali R, Gummer AW, van Rienen U. Understanding the impact of modiolus porosity on stimulation of spiral ganglion neurons by cochlear implants. Sci Rep 2024; 14:9593. [PMID: 38671022 PMCID: PMC11053021 DOI: 10.1038/s41598-024-59347-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 04/09/2024] [Indexed: 04/28/2024] Open
Abstract
Moderate-to-profound sensorineural hearing loss in humans is treatable by electrically stimulating the auditory nerve (AN) with a cochlear implant (CI). In the cochlea, the modiolus presents a porous bony interface between the CI electrode and the AN. New bone growth caused by the presence of the CI electrode or neural degeneration inflicted by ageing or otological diseases might change the effective porosity of the modiolus and, thereby, alter its electrical material properties. Using a volume conductor description of the cochlea, with the aid of a 'mapped conductivity' method and an ad-hoc 'regionally kinetic' equation system, we show that even a slight variation in modiolus porosity or pore distribution can disproportionately affect AN stimulation. Hence, because of porosity changes, an inconsistent CI performance might occur if neural degeneration or new bone growth progress after implantation. Appropriate electrical material properties in accordance with modiolar morphology and pathology should be considered in patient-specific studies. The present first-of-its-kind in-silico study advocates for contextual experimental studies to further explore the utility of modiolus porous morphology in optimising the CI outcome.
Collapse
Affiliation(s)
- Kiran K Sriperumbudur
- Institute of General Electrical Engineering, University of Rostock, Rostock, Germany.
- Research and Development, MED-EL Medical Electronics GmbH, Innsbruck, Austria.
| | - Revathi Appali
- Institute of General Electrical Engineering, University of Rostock, Rostock, Germany
- Ageing of Individuals and Society, Interdisciplinary Faculty, University of Rostock, Rostock, Germany
| | - Anthony W Gummer
- Department of Otolaryngology, University of Tübingen, Tübingen, Germany.
- Department of Otolaryngology, University of Melbourne, Melbourne, Australia.
| | - Ursula van Rienen
- Institute of General Electrical Engineering, University of Rostock, Rostock, Germany
- Ageing of Individuals and Society, Interdisciplinary Faculty, University of Rostock, Rostock, Germany
- Life, Light and Matter, Interdisciplinary Faculty, University of Rostock, Rostock, Germany
| |
Collapse
|
7
|
Schoovaerts M, Ourak M, Borghesan G, Putzeys T, Poorten EV, Verhaert N. OCT-based intra-cochlear imaging and 3D reconstruction: ex vivo validation of a robotic platform. Int J Comput Assist Radiol Surg 2024:10.1007/s11548-024-03081-7. [PMID: 38436923 DOI: 10.1007/s11548-024-03081-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 02/15/2024] [Indexed: 03/05/2024]
Abstract
PURPOSE The small size of the cochlea, and its location deeply embedded in thick temporal bone, poses a challenge for intra-cochlear guidance and diagnostics. Current radiological imaging techniques are not able to visualize the cochlear microstructures in detail. Rotational optical coherence tomography (OCT) fibers show great potential for intra-cochlear guidance. The generated images could be used to map, and study, the tiny cochlear microstructures relevant for hearing. METHODS This work describes the design of a rotational OCT probe with an outer diameter of 0.9 mm. It further discusses a robotic system, which features a remote center of motion mechanism, dedicated to the probe's positioning, fine manipulation and stable insertion into the cochlear micro-spaces. Furthermore, the necessary calibration steps for 3D reconstruction are described, followed by a detailed quantitative analysis, comparing the 3D reconstructions using a synthetic, 2:1 scaled scala tympani model with a reconstruction from micro-CT, serving as the ground truth. Finally, the potential of the system is demonstrated by scanning a single ex vivo cadaveric human cochlea. RESULTS The study investigates five insertions in the same 2:1 scaled tympani model, along with their corresponding 3D reconstruction. The comparison with micro-CT results in an average root-mean-square error of 74.2 µm, a signed distance error of 38.1 µm and a standard deviation of 63.6 µm. The average F-score of the reconstructions, using a distance threshold of 100 and 74.2 µm, resulted in 83.0% and 71.8%, respectively. Insertion in the cadaveric human cochlea showed the challenges for straight insertion, i.e., navigating the hook region. CONCLUSION Overall, the system shows great potential for intra-cochlear guidance and diagnostics, due to the system's capability for precise and stable insertion into the basal turn in the scala tympani. The system, combined with the calibration procedure, results in detailed and precise 3D reconstructions.
Collapse
Affiliation(s)
- Maarten Schoovaerts
- Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300, 3001, Leuven, Belgium.
- Department of Neurosciences, KU Leuven, Herestraat 49, 3001, Leuven, Belgium.
| | - Mouloud Ourak
- Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300, 3001, Leuven, Belgium
| | - Gianni Borghesan
- Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300, 3001, Leuven, Belgium
- Flanders Make, KU Leuven, Celestijnenlaan 300, 3001, Leuven, Belgium
| | - Tristan Putzeys
- Department of Neurosciences, KU Leuven, Herestraat 49, 3001, Leuven, Belgium
- Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200, 3001, Leuven, Belgium
| | | | - Nicolas Verhaert
- Department of Neurosciences, KU Leuven, Herestraat 49, 3001, Leuven, Belgium
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital of Leuven, Herestraat 49, 3001, Leuven, Belgium
| |
Collapse
|
8
|
Thiselton J, Hanekom T. Parameterisation and Prediction of Intra-canal Cochlear Structures. Ann Biomed Eng 2024; 52:695-706. [PMID: 38165632 PMCID: PMC10859348 DOI: 10.1007/s10439-023-03417-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 12/03/2023] [Indexed: 01/04/2024]
Abstract
Accurate 3D models of the cochlea are useful tools for research in the relationship between the electrode array and nerve fibres. The internal geometry of the cochlear canal plays an important role in understanding and quantifying that relationship. Predicting the location and shapes of the geometry is done by measuring histologic sections and fitting equations that can be used to predict parameters that fully define the geometry. A parameter sensitivity analysis is employed to prove that the size and location of the spiral lamina are the characteristics that most influence current distribution along target nerve fibres. The proposed landmark prediction method more accurately predicts the location of the points defining the spiral lamina in the apical region of the cochlea than methods used in previous modelling attempts. Thus, this technique can be used to generate 2D geometries that can be expanded to 3D models when high-resolution imaging is not available.
Collapse
Affiliation(s)
- Joshua Thiselton
- Bioengineering, Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Lynnwood Road, Pretoria, 0002, Gauteng, South Africa
| | - Tania Hanekom
- Bioengineering, Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Lynnwood Road, Pretoria, 0002, Gauteng, South Africa.
| |
Collapse
|
9
|
Räth M, Schurzig D, Timm ME, Lenarz T, Warnecke A. Correlation of Scalar Cochlear Volume and Hearing Preservation in Cochlear Implant Recipients with Residual Hearing. Otol Neurotol 2024; 45:256-265. [PMID: 38361293 DOI: 10.1097/mao.0000000000004122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
OBJECTIVE Preservation of residual hearing is one of the main goals in cochlear implantation. There are many factors that can influence hearing preservation after cochlear implantation. The purpose of the present study was to develop an algorithm for validated preoperative cochlear volume analysis and to elucidate the role of cochlear volume in preservation of residual hearing preservation after atraumatic cochlear implantation. STUDY DESIGN Retrospective analysis. SETTING Tertiary referral center. PATIENTS A total of 166 cochlear implant recipients were analyzed. All patients were implanted with either a MED-EL (Innsbruck, Austria) FLEXSOFT (n = 3), FLEX28 (n = 72), FLEX26 (n = 1), FLEX24 (n = 41), FLEX20 (n = 38), or FLEX16 (n = 11, custom made device) electrode array through a round window approach. Main outcome measures: Cochlear volume as assessed after manual segmentation of cochlear cross-sections in cone beam computed tomography, and preservation of residual hearing 6 months after implantation were analyzed. The association between residual hearing preservation and cochlear volume was then assessed statistically. RESULTS Rapid and valid cochlear volume analysis was possible using the individual cross-sections and a newly developed and validated algorithm. Cochlear volume had the tendency to be larger in patients with hearing preservation than in those with hearing loss. Significant correlations with hearing preservation could be observed for the basal width and length of the basal turn. CONCLUSIONS Preservation of residual hearing after cochlear implantation may depend on cochlear volume but appears to be influenced more strongly by other cochlear dimensions.
Collapse
|
10
|
Quass GL, Kral A. Tripolar configuration and pulse shape in cochlear implants reduce channel interactions in the temporal domain. Hear Res 2024; 443:108953. [PMID: 38277881 DOI: 10.1016/j.heares.2024.108953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 01/08/2024] [Accepted: 01/11/2024] [Indexed: 01/28/2024]
Abstract
The present study investigates effects of current focusing and pulse shape on threshold, dynamic range, spread of excitation and channel interaction in the time domain using cochlear implant stimulation. The study was performed on 20 adult guinea pigs using a 6-channel animal cochlear implant, recording was performed in the auditory midbrain using a multielectrode array. After determining the best frequencies for individual recording contacts with acoustic stimulation, the ear was deafened and a cochlear implant was inserted into the cochlea. The position of the implant was controlled by x-ray. Stimulation with biphasic, pseudomonophasic and monophasic stimuli was performed with monopolar, monopolar with common ground, bipolar and tripolar configuration in two sets of experiments, allowing comparison of the effects of the different stimulation strategies on threshold, dynamic range, spread of excitation and channel interaction. Channel interaction was studied in the temporal domain, where two electrodes were activated with pulse trains and phase locking to these pulse trains in the midbrain was quantified. The results documented multifactorial influences on the response properties, with significant interaction between factors. Thresholds increased with increasing current focusing, but decreased with pseudomonophasic and monophasic pulse shapes. The results documented that current focusing, particularly tripolar configuration, effectively reduces channel interaction, but that also pseudomonophasic and monophasic stimulation and phase duration intensity coding reduce channel interactions.
Collapse
Affiliation(s)
- Gunnar L Quass
- Institute for AudioNeuroTechnology (VIANNA) & Department of Experimental Otology, Otolaryngology Clinics, Hannover Medical School, Hannover, Germany; Cluster of Excellence "Hearing4All" (EXC 2177), Germany.
| | - Andrej Kral
- Institute for AudioNeuroTechnology (VIANNA) & Department of Experimental Otology, Otolaryngology Clinics, Hannover Medical School, Hannover, Germany; Cluster of Excellence "Hearing4All" (EXC 2177), Germany; Australian Hearing Hub, School of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| |
Collapse
|
11
|
Malhotra V, Kumar S, Menon GS, Hejjaji Krishnamurthy A, Medikeri S, Dutt SN. Morphometric Analysis of Temporal Bone Radiology for Cochlear Implant Candidacy. Indian J Otolaryngol Head Neck Surg 2024; 76:702-711. [PMID: 38440533 PMCID: PMC10908920 DOI: 10.1007/s12070-023-04257-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 09/28/2023] [Indexed: 03/06/2024] Open
Abstract
Cochlear Implantation (CI) is a well-accepted treatment for severe-to-profound sensorineural hearing loss, refractory to conventional hearing amplification. Pre-operative Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) play pivotal roles in patient selection to rule out findings that preclude surgery or identify conditions that may impact the surgical procedure. A prospective study was carried out in a tertiary care center over three years, from January 2020 to January 2023. One hundred and ninety (380 ears) patients' High-Resolution Computed Tomography (HRCT) studies of the temporal bone and MRI scans of the auditory pathways were analyzed. A reporting format was followed which was devised by a team of senior implant surgeons and senior neuro-radiologists. Our study aims to provide a comprehensive radiologic protocol for CI candidacy including normative data for the essential morphometrics in the Indian setting.
Collapse
|
12
|
Stritzel J, Ebrahimzadeh AH, Büchner A, Lanfermann H, Marschollek M, Wolff D. Landmark-based registration of a cochlear model to a human cochlea using conventional CT scans. Sci Rep 2024; 14:1115. [PMID: 38212412 PMCID: PMC10784596 DOI: 10.1038/s41598-023-50632-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 12/22/2023] [Indexed: 01/13/2024] Open
Abstract
Cochlear implants can provide an advanced treatment option to restore hearing. In standard pre-implant procedures, many factors are already considered, but it seems that not all underlying factors have been identified yet. One reason is the low quality of the conventional computed tomography images taken before implantation, making it difficult to assess these parameters. A novel method is presented that uses the Pietsch Model, a well-established model of the human cochlea, as well as landmark-based registration to address these challenges. Different landmark numbers and placements are investigated by visually comparing the mean error per landmark and the registrations' results. The landmarks on the first cochlear turn and the apex are difficult to discern on a low-resolution CT scan. It was possible to achieve a mean error markedly smaller than the image resolution while achieving a good visual fit on a cochlear segment and directly in the conventional computed tomography image. The employed cochlear model adjusts image resolution problems, while the effort of setting landmarks is markedly less than the segmentation of the whole cochlea. As a next step, the specific parameters of the patient could be extracted from the adapted model, which enables a more personalized implantation with a presumably better outcome.
Collapse
Affiliation(s)
- Jenny Stritzel
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, Hannover, Germany.
| | - Amir Hossein Ebrahimzadeh
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, Hannover, Germany
| | - Andreas Büchner
- German Hearing Center, Hannover Medical School, Hannover, Germany
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
| | - Heinrich Lanfermann
- Institute of Diagnostic and Interventional Neuroradiology, Hannover Medical School, Hannover, Germany
| | - Michael Marschollek
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, Hannover, Germany
| | - Dominik Wolff
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, Hannover, Germany
| |
Collapse
|
13
|
Gerbert M, Ernst A, Seidl R, Decker L, Scholz S, Lauer G, Mittmann P. Preservation of Residual Hearing: Long-Term Results With a Mid-Scala Electrode. J Otolaryngol Head Neck Surg 2024; 53:19160216241250351. [PMID: 38888946 PMCID: PMC11155315 DOI: 10.1177/19160216241250351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 03/30/2024] [Indexed: 06/20/2024] Open
Abstract
OBJECTIVE The long-term preservation of residual hearing after cochlear implantation has become a major goal over the past few years. The aim of the present study was to evaluate residual hearing in the long-term follow-up using mid-scala electrodes. METHODS In this retrospective, single-center study, we collected data from 27 patients who were implanted between 2014 and 2015 with residual hearing in the low-frequency range using a mid-scala electrode. Measurements of the hearing thresholds were carried out directly postoperatively (day 1 after surgery) and in the long-term follow-up 43.7 ± 6.9 months. The calculation of the extent of audiological hearing preservation was determined using the HEARRING group formula by Skarsynski. RESULTS Postoperative preservation of residual hearing was achieved in 69.2% of the cases in the low-frequency range between 250 Hz and 1 kHz, of which 89.5% of the patients had frequencies that suggested using electroacoustic stimulation (EAS). In the long-term follow-up, 30.8% of the patients showed residual hearing; however, 57.1% had apparently benefited from EAS. CONCLUSION Preservation of residual hearing is feasible in the long term using mid-scala electrodes. Postoperatively, there is over the half of patients who benefit from an EAS strategy. The long-term follow-up shows a certain decrease in residual hearing. However, these results are comparable to studies relating to other types of electrodes. Further research should be conducted in future to better evaluate hearing loss in long-term follow-up, compared to direct postoperative audiological results.
Collapse
Affiliation(s)
- Martin Gerbert
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Arne Ernst
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Rainer Seidl
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Lars Decker
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Sandra Scholz
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Gina Lauer
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Philipp Mittmann
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| |
Collapse
|
14
|
Micaletti F, Escoffre JM, Kerneis S, Bouakaz A, Galvin JJ, Boullaud L, Bakhos D. Microbubble-assisted ultrasound for inner ear drug delivery. Adv Drug Deliv Rev 2024; 204:115145. [PMID: 38042259 DOI: 10.1016/j.addr.2023.115145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 11/20/2023] [Accepted: 11/22/2023] [Indexed: 12/04/2023]
Abstract
Treating pathologies of the inner ear is a major challenge. To date, a wide range of procedures exists for administering therapeutic agents to the inner ear, with varying degrees of success. The key is to deliver therapeutics in a way that is minimally invasive, effective, long-lasting, and without adverse effects on vestibular and cochlear function. Microbubble-assisted ultrasound ("sonoporation") is a promising new modality that can be adapted to the inner ear. Combining ultrasound technology with microbubbles in the middle ear can increase the permeability of the round window, enabling therapeutic agents to be delivered safely and effectively to the inner ear in a targeted manner. As such, sonoporation is a promising new approach to treat hearing loss and vertigo. This review summarizes all studies on the delivery of therapeutic molecules to the inner ear using sonoporation.
Collapse
Affiliation(s)
- Fabrice Micaletti
- ENT and Cervico-Facial Surgery Department, University Hospital Center of Tours, 2 Boulevard Tonnellé, 37044 Tours, France.
| | | | - Sandrine Kerneis
- ENT and Cervico-Facial Surgery Department, University Hospital Center of Tours, 2 Boulevard Tonnellé, 37044 Tours, France
| | - Ayache Bouakaz
- UMR 1253, iBrain, Université de Tours, Inserm, Tours, France
| | - John J Galvin
- Faculty of medicine, Université de Tours, 10 boulevard Tonnellé, 37044 Tours, France; House Institute Foundation, 2100 W 3rd Street, Suite 111, Los Angeles, CA 90057, USA
| | - Luc Boullaud
- ENT and Cervico-Facial Surgery Department, University Hospital Center of Tours, 2 Boulevard Tonnellé, 37044 Tours, France
| | - David Bakhos
- ENT and Cervico-Facial Surgery Department, University Hospital Center of Tours, 2 Boulevard Tonnellé, 37044 Tours, France; UMR 1253, iBrain, Université de Tours, Inserm, Tours, France; Faculty of medicine, Université de Tours, 10 boulevard Tonnellé, 37044 Tours, France; House Institute Foundation, 2100 W 3rd Street, Suite 111, Los Angeles, CA 90057, USA
| |
Collapse
|
15
|
Grzybowski M, Malfeld K, Lenarz T, Scheper V, Schurzig D. Optimization of pharmacological interventions in the guinea pig animal model-a new approach to calculate the perilymph volume of the scala tympani. Front Neurosci 2023; 17:1297046. [PMID: 38161797 PMCID: PMC10754993 DOI: 10.3389/fnins.2023.1297046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 11/29/2023] [Indexed: 01/03/2024] Open
Abstract
Objective The guinea pig serves as a well-established animal model for inner ear research, offering valuable insights into the anatomy, physiology, and therapeutic interventions of the auditory system. However, the heterogeneity of results observed in both in-vivo experiments and clinical studies poses challenges in understanding and optimizing pharmacotherapy outcomes. This heterogeneity may be due to individual differences in the size of the guinea pig cochlea and thus in the volume of the scala tympani (ST), which can lead to different drug concentrations in the ST, a fact that has been largely overlooked thus far. To address this issue, we aimed to develop an approach for calculating the individual volume of perilymph within the ST before and after cochlear implant insertion. Method In this study, high-resolution μCT images of a total of n = 42 guinea pig temporal bones were used to determine the volume of the ST. We compared fresh, frozen, and fixed tissues from both colored and albino strains to evaluate the potential influence of tissue condition and strain on the results. Results Our findings demonstrate a variability in mean ST volume with a relative standard deviation (RSD) of 14.7%, comparable to studies conducted with humans (range RSD: 5 to 20%). This indicates that the guinea pig cochlea exhibits similar variability to that of the human cochlea. Consequently, it is crucial to consider this variability when designing and conducting studies utilizing the guinea pig as an animal model. Furthermore, we successfully developed a tool capable of estimating ST volume without the need for manual segmentation, employing two geometric parameters, basal diameter (A) and width (B) of the cochlea, corresponding to the cochlear footprint. The tool is available for free download and use on our website. Conclusion This novel approach provides researchers with a valuable tool to calculate individual ST volume in guinea pigs, enabling more precise dosing strategies and optimization of drug concentrations for pharmacotherapy studies. Moreover, our study underscores the importance of acknowledging and accounting for inter-individual variability in animal models to enhance the translational relevance and applicability of research outcomes in the field of inner ear investigations.
Collapse
Affiliation(s)
- Marleen Grzybowski
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hannover, Germany
- German Hearing Center Hannover, Hannover Medical School, Hannover, Germany
| | - Kathrin Malfeld
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hannover, Germany
- Center for Biomedical Engineering, Implant Research and Development (NIFE), Hannover Medical School, Hannover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hannover, Germany
- German Hearing Center Hannover, Hannover Medical School, Hannover, Germany
- Center for Biomedical Engineering, Implant Research and Development (NIFE), Hannover Medical School, Hannover, Germany
| | - Verena Scheper
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hannover, Germany
- Center for Biomedical Engineering, Implant Research and Development (NIFE), Hannover Medical School, Hannover, Germany
| | - Daniel Schurzig
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hannover, Germany
- MED-EL Research Center, Hannover, Germany
| |
Collapse
|
16
|
Tropitzsch A, Schade-Mann T, Gamerdinger P, Dofek S, Schulte B, Schulze M, Fehr S, Biskup S, Haack TB, Stöbe P, Heyd A, Harre J, Lesinski-Schiedat A, Büchner A, Lenarz T, Warnecke A, Müller M, Vona B, Dahlhoff E, Löwenheim H, Holderried M. Variability in Cochlear Implantation Outcomes in a Large German Cohort With a Genetic Etiology of Hearing Loss. Ear Hear 2023; 44:1464-1484. [PMID: 37438890 PMCID: PMC10583923 DOI: 10.1097/aud.0000000000001386] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 04/04/2023] [Indexed: 07/14/2023]
Abstract
OBJECTIVES The variability in outcomes of cochlear implantation is largely unexplained, and clinical factors are not sufficient for predicting performance. Genetic factors have been suggested to impact outcomes, but the clinical and genetic heterogeneity of hereditary hearing loss makes it difficult to determine and interpret postoperative performance. It is hypothesized that genetic mutations that affect the neuronal components of the cochlea and auditory pathway, targeted by the cochlear implant (CI), may lead to poor performance. A large cohort of CI recipients was studied to verify this hypothesis. DESIGN This study included a large German cohort of CI recipients (n = 123 implanted ears; n = 76 probands) with a definitive genetic etiology of hearing loss according to the American College of Medical Genetics (ACMG)/Association for Molecular Pathology (AMP) guidelines and documented postoperative audiological outcomes. All patients underwent preoperative clinical and audiological examinations. Postoperative CI outcome measures were based on at least 1 year of postoperative audiological follow-up for patients with postlingual hearing loss onset (>6 years) and 5 years for children with congenital or pre/perilingual hearing loss onset (≤6 years). Genetic analysis was performed based on three different methods that included single-gene screening, custom-designed hearing loss gene panel sequencing, targeting known syndromic and nonsyndromic hearing loss genes, and whole-genome sequencing. RESULTS The genetic diagnosis of the 76 probands in the genetic cohort involved 35 genes and 61 different clinically relevant (pathogenic, likely pathogenic) variants. With regard to implanted ears (n = 123), the six most frequently affected genes affecting nearly one-half of implanted ears were GJB2 (21%; n = 26), TMPRSS3 (7%; n = 9), MYO15A (7%; n = 8), SLC26A4 (5%; n = 6), and LOXHD1 and USH2A (each 4%; n = 5). CI recipients with pathogenic variants that influence the sensory nonneural structures performed at or above the median level of speech performance of all ears at 70% [monosyllable word recognition score in quiet at 65 decibels sound pressure level (SPL)]. When gene expression categories were compared to demographic and clinical categories (total number of compared categories: n = 30), mutations in genes expressed in the spiral ganglion emerged as a significant factor more negatively affecting cochlear implantation outcomes than all clinical parameters. An ANOVA of a reduced set of genetic and clinical categories (n = 10) identified five detrimental factors leading to poorer performance with highly significant effects ( p < 0.001), accounting for a total of 11.8% of the observed variance. The single strongest category was neural gene expression accounting for 3.1% of the variance. CONCLUSIONS The analysis of the relationship between the molecular genetic diagnoses of a hereditary etiology of hearing loss and cochlear implantation outcomes in a large German cohort of CI recipients revealed significant variabilities. Poor performance was observed with genetic mutations that affected the neural components of the cochlea, supporting the "spiral ganglion hypothesis."
Collapse
Affiliation(s)
- Anke Tropitzsch
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
- Hearing Center, Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
- Center for Rare Hearing Disorders, Centre for Rare Diseases, University of Tübingen, Tübingen, Germany
- Neurosensory Center, Departments of Otolaryngology—Head & Neck Surgery and Ophthalmology, University of Tübingen Medical Center, Tübingen, Germany
| | - Thore Schade-Mann
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
- Hearing Center, Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
| | - Philipp Gamerdinger
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
- Hearing Center, Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
| | - Saskia Dofek
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
| | - Björn Schulte
- CeGaT GmbH und Praxis für Humangenetik Tübingen, Tübingen, Germany
| | - Martin Schulze
- CeGaT GmbH und Praxis für Humangenetik Tübingen, Tübingen, Germany
| | - Sarah Fehr
- CeGaT GmbH und Praxis für Humangenetik Tübingen, Tübingen, Germany
| | - Saskia Biskup
- CeGaT GmbH und Praxis für Humangenetik Tübingen, Tübingen, Germany
| | - Tobias B. Haack
- Institute of Medical Genetics and Applied Genomics, University of Tübingen, Tübingen, Germany
| | - Petra Stöbe
- Institute of Medical Genetics and Applied Genomics, University of Tübingen, Tübingen, Germany
| | - Andreas Heyd
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
| | - Jennifer Harre
- Department of Otorhinolaryngology—Head & Neck Surgery, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4all” of the German Research Foundation, Hannover, Germany
| | - Anke Lesinski-Schiedat
- Department of Otorhinolaryngology—Head & Neck Surgery, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4all” of the German Research Foundation, Hannover, Germany
| | - Andreas Büchner
- Department of Otorhinolaryngology—Head & Neck Surgery, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4all” of the German Research Foundation, Hannover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology—Head & Neck Surgery, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4all” of the German Research Foundation, Hannover, Germany
| | - Athanasia Warnecke
- Department of Otorhinolaryngology—Head & Neck Surgery, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4all” of the German Research Foundation, Hannover, Germany
| | - Marcus Müller
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
- Neurosensory Center, Departments of Otolaryngology—Head & Neck Surgery and Ophthalmology, University of Tübingen Medical Center, Tübingen, Germany
| | - Barbara Vona
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
- Neurosensory Center, Departments of Otolaryngology—Head & Neck Surgery and Ophthalmology, University of Tübingen Medical Center, Tübingen, Germany
| | - Ernst Dahlhoff
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
- Neurosensory Center, Departments of Otolaryngology—Head & Neck Surgery and Ophthalmology, University of Tübingen Medical Center, Tübingen, Germany
| | - Hubert Löwenheim
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
- Neurosensory Center, Departments of Otolaryngology—Head & Neck Surgery and Ophthalmology, University of Tübingen Medical Center, Tübingen, Germany
| | - Martin Holderried
- Department of Otolaryngology—Head & Neck Surgery, University of Tübingen Medical Center, Tübingen, Germany
- Department of Medical Development and Quality Management, University Hospital Tübingen, Tübingen, Germany
| |
Collapse
|
17
|
Engert J, Bauer D, Spahn B, Müller-Graff FT, Voelker J, Neun T, Althoff D, Hagen R, Hackenberg S, Rak K. Computed tomographic 3D analysis of the cochlear aqueduct-potential and limitations of clinical imaging. Acta Otolaryngol 2023; 143:931-935. [PMID: 38127466 DOI: 10.1080/00016489.2023.2294921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 12/07/2023] [Indexed: 12/23/2023]
Abstract
Background: The cochlear aqueduct (CA), which connects the scala tympani and the subarachnoid space, and its accompanying structures appear to have a significant relevance during cochlear implantation and an accurate visualization in clinical imaging is of great interest. Aims and Objective: This study aims to determine which potential and limitations clinically available imaging modalities have in the visualization of the CA. Methods: Micro-CT, flat-panel volume computed tomography with and without secondary reconstruction (fpVCT, fpVCTseco) and multislice computed tomography (MSCT) of 10 temporal bone specimen were used for 3D analysis of the CA. Results: FpVCTseco proved superior in visualizing the associated structures and lateral portions of the CA, which merge into the basal turn of the cochlea. All clinical imaging modalities proved equal in analyzing the length, total volume of the CA and its area of the medial orifice. Conclusion: The choice of the most accurate clinical imaging modality to evaluate the CA and its associated structures depends on the clinical or scientific question. Furthermore, this study should provide a basis for further investigations analyzing the CA.
Collapse
Affiliation(s)
- Jonas Engert
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Daniel Bauer
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Bjoern Spahn
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Franz-Tassilo Müller-Graff
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Johannes Voelker
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Tilmann Neun
- Institute for Diagnostic and Interventional Neuroradiology, University of Wuerzburg, Wuerzburg, Germany
| | - Daniel Althoff
- Fraunhofer Development Center for X-ray Technology, Wuerzburg, Germany
| | - Rudolf Hagen
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Stephan Hackenberg
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Kristen Rak
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Wuerzburg, Wuerzburg, Germany
| |
Collapse
|
18
|
Gatto A, Tofanelli M, Costariol L, Rizzo S, Borsetto D, Gardenal N, Uderzo F, Boscolo-Rizzo P, Tirelli G. Otological Planning Software-OTOPLAN: A Narrative Literature Review. Audiol Res 2023; 13:791-801. [PMID: 37887851 PMCID: PMC10603892 DOI: 10.3390/audiolres13050070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/10/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023] Open
Abstract
The cochlear implant (CI) is a widely accepted option in patients with severe to profound hearing loss receiving limited benefit from traditional hearing aids. CI surgery uses a default setting for frequency allocation aiming to reproduce tonotopicity, thus mimicking the normal cochlea. One emerging instrument that may substantially help the surgeon before, during, and after the surgery is a surgical planning software product developed in collaboration by CASCINATION AG (Bern, Switzerland) and MED-EL (Innsbruck Austria). The aim of this narrative review is to present an overview of the main features of this otological planning software, called OTOPLAN®. The literature was searched on the PubMed and Web of Science databases. The search terms used were "OTOPLAN", "cochlear planning software" "three-dimensional imaging", "3D segmentation", and "cochlear implant" combined into different queries. This strategy yielded 52 publications, and a total of 31 studies were included. The review of the literature revealed that OTOPLAN is a useful tool for otologists and audiologists as it improves preoperative surgical planning both in adults and in children, guides the intraoperative procedure and allows postoperative evaluation of the CI.
Collapse
Affiliation(s)
- Annalisa Gatto
- Department of Medical, Surgical and Health Sciences, Section of Otolaryngology, University of Trieste, 34149 Trieste, Italy; (A.G.); (N.G.); (G.T.)
| | - Margherita Tofanelli
- Department of Medical, Surgical and Health Sciences, Section of Otolaryngology, University of Trieste, 34149 Trieste, Italy; (A.G.); (N.G.); (G.T.)
| | - Ludovica Costariol
- Department of Medical, Surgical and Health Sciences, Section of Otolaryngology, University of Trieste, 34149 Trieste, Italy; (A.G.); (N.G.); (G.T.)
| | - Serena Rizzo
- Department of Medical, Surgical and Health Sciences, Section of Otolaryngology, University of Trieste, 34149 Trieste, Italy; (A.G.); (N.G.); (G.T.)
| | - Daniele Borsetto
- Department of ENT, Addenbrookes Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge CB2 0QQ, UK
| | - Nicoletta Gardenal
- Department of Medical, Surgical and Health Sciences, Section of Otolaryngology, University of Trieste, 34149 Trieste, Italy; (A.G.); (N.G.); (G.T.)
| | - Francesco Uderzo
- Department of Medical, Surgical and Health Sciences, Section of Otolaryngology, University of Trieste, 34149 Trieste, Italy; (A.G.); (N.G.); (G.T.)
| | - Paolo Boscolo-Rizzo
- Department of Medical, Surgical and Health Sciences, Section of Otolaryngology, University of Trieste, 34149 Trieste, Italy; (A.G.); (N.G.); (G.T.)
| | - Giancarlo Tirelli
- Department of Medical, Surgical and Health Sciences, Section of Otolaryngology, University of Trieste, 34149 Trieste, Italy; (A.G.); (N.G.); (G.T.)
| |
Collapse
|
19
|
Sieber D, Timm ME, Weller T, Suhling M, Lenarz T, Schurzig D. The Dependency of Cochlear Lateral Wall Measurements on Observer and Imaging Type. Otol Neurotol 2023; 44:873-880. [PMID: 37641206 DOI: 10.1097/mao.0000000000003991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
HYPOTHESIS Assessment techniques for the cochlear spatial lateral wall are associated with inter-rater variability, but derived clinical recommendations nonetheless offer value for individualized electrode selection. BACKGROUND Anatomical variations influence the location of cochlear implant electrodes inside the cochlea. Preoperative planning allows individualization of the electrode based on characterization of the bony lateral wall. METHODS The study used publicly available digitized temporal bones based on microslicing and computed tomography. Four experienced observers assessed the lateral wall applying manual tracing, linear regression scaling and elliptic-circular approximation methods in all modalities. Radial and height differences were computed in 90-degree steps from the round window center to the apex. Total length, total angular length, and tonotopic frequencies were computed for each reconstruction. RESULTS Differences were found most pronounced between assessment methods in vertical direction across observers and imaging modalities. One of the five anatomies was consistently found to be of shorter cochlear duct length with estimation techniques yielding more conservative results compared with manual tracings. CONCLUSIONS Assessment techniques for the bony lateral wall yield method, observer, and image modality related deviations. Automation of the anatomical characterization may offer potential in minimizing inaccuracies. Nonetheless, observers were consistently able to detect a smaller inner ear demonstrating the ability of current methods to contribute to an optimized choice of electrodes based on individual patient anatomy.
Collapse
Affiliation(s)
- Daniel Sieber
- Department of Medical and Health Technologies, MCI The Entrepreneurial School, Innsbruck, Austria
| | - Max E Timm
- Department of Otolaryngology, Hannover Medical School
| | - Tobias Weller
- Department of Otolaryngology, Hannover Medical School
| | - Marie Suhling
- Department of Otolaryngology, Hannover Medical School
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School
| | | |
Collapse
|
20
|
Aksoy DO, Meltem E, Karagoz Y, Ulusan MB, Mahmutoglu O, Mahmutoglu AS. The Cochlear Size Variations in Incomplete Partitions with Multiplanar Images on Pediatric Temporal Bone CT. SISLI ETFAL HASTANESI TIP BULTENI 2023; 57:426-433. [PMID: 37900333 PMCID: PMC10600602 DOI: 10.14744/semb.2023.65725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 06/06/2023] [Accepted: 08/04/2023] [Indexed: 10/31/2023]
Abstract
Objectives The purpose of the study was to evaluate cochlea dimensions by the multiplanar reconstruction of high-resolution computed tomography that could be useful in diagnosing incomplete partition (IP) malformations. Methods This study included 32 patients with 64 side cochleae diagnosed with IP defect and 38 cochleae as the control without any defect. Basal turn length (BL), cochlear height (CH), Mid-apical length (MAL), Mid-apical height, Cochlear length (A), and Cochlear width (B) were measured on reformat images. Results Twenty cochleae of these patients have been diagnosed with IP type I, 34 with IP type II, and 10 with IP type III. The MAL values are shorter than the control group in IP types I and III (p<0.001, p<0.001). BL values are shorter in IP type III cases (p<0.001). In IP II cases, BL and MAL values overlapped with the control group. CH did not differ significantly from the control group in any IP type. A and B values were significantly lower than the control group for IP I and III (p<0.01). There is a positive correlation between A and B values for all IP types (p<0.01). Conclusion Quantitative data about differences in the size and shape of the cochlea in IP cases would help differentiate them from the normal cochlea. Since A and B values showed a positive correlation, it is suggested that A and B values can be used to estimate CDL for IP types.
Collapse
Affiliation(s)
- Direnc Ozlem Aksoy
- Department of Radiology, University of Health Sciences Türkiye, Istanbul Training and Research Hospital, Istanbul, Türkiye
| | - Emine Meltem
- Department of Radiology, University of Health Sciences Türkiye, Istanbul Training and Research Hospital, Istanbul, Türkiye
| | - Yesim Karagoz
- Department of Radiology, University of Health Sciences Türkiye, Istanbul Training and Research Hospital, Istanbul, Türkiye
| | - Melis Baykara Ulusan
- Department of Radiology, University of Health Sciences Türkiye, Istanbul Training and Research Hospital, Istanbul, Türkiye
| | - Ozdes Mahmutoglu
- Department of Radiology, University of Health Sciences Türkiye, Sisli Hamidiye Etfal Training and Research Hospital, Istanbul, Türkiye
| | - Abdullah Soydan Mahmutoglu
- Department of Radiology, University of Health Sciences Türkiye, Istanbul Training and Research Hospital, Istanbul, Türkiye
| |
Collapse
|
21
|
Távora-Vieira D, Voola M, Kuthubutheen J, Friedland P, Gibson D, Acharya A. Evaluation of the Performance of OTOPLAN-Based Cochlear Implant Electrode Array Selection: A Retrospective Study. J Pers Med 2023; 13:1276. [PMID: 37623526 PMCID: PMC10455663 DOI: 10.3390/jpm13081276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 08/18/2023] [Accepted: 08/17/2023] [Indexed: 08/26/2023] Open
Abstract
Otoplan is a surgical planning software designed to assist with cochlear implant surgery. One of its outputs is a recommendation of electrode array type based on imaging parameters. In this retrospective study, we evaluated the differences in auditory outcomes between patients who were implanted with arrays corresponding to those recommended by the Otoplan software versus those in which the array selection differed from the Otoplan recommendation. Pre-operative CT images from 114 patients were imported into the software, and array recommendations were generated. These were compared to the arrays which had actually been implanted during surgery, both in terms of array type and length. As recommended, 47% of patients received the same array, 34% received a shorter array, and 18% received a longer array. For reasons relating to structure and hearing preservation, 83% received the more flexible arrays. Those who received stiffer arrays had cochlear malformations or ossification. A negative, although non-statistically significant correlation was observed between the CNC scores at 12 months and the absolute value of the difference between recommended array and implanted array. In conclusion, clinicians may be slightly biased toward shorter electrode arrays due to their perceived greater ability to achieve full insertion. Using 3D imaging during the pre-operative planning may improve clinicians' confidence to implant longer electrode arrays, where appropriate, to achieve optimum hearing outcomes.
Collapse
Affiliation(s)
- Dayse Távora-Vieira
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
- Medical School, Division of Surgery, The University of Western Australia, Perth, WA 6010, Australia
- Faculty of Health Sciences, School of Allied Health, Curtin University, Perth, WA 6102, Australia
| | - Marcus Voola
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
- Medical School, Division of Surgery, The University of Western Australia, Perth, WA 6010, Australia
| | - Jafri Kuthubutheen
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
- Medical School, Division of Surgery, The University of Western Australia, Perth, WA 6010, Australia
- Sir Charles Gairdner Hospital, Perth, WA 6009, Australia
| | - Peter Friedland
- Medical School, Division of Surgery, The University of Western Australia, Perth, WA 6010, Australia
- Sir Charles Gairdner Hospital, Perth, WA 6009, Australia
| | - Daren Gibson
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
| | - Aanand Acharya
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
| |
Collapse
|
22
|
Curtis DP, Baumann AN, Jeyakumar A. Variation in cochlear size: A systematic review. Int J Pediatr Otorhinolaryngol 2023; 171:111659. [PMID: 37459768 DOI: 10.1016/j.ijporl.2023.111659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 06/22/2023] [Accepted: 07/09/2023] [Indexed: 07/26/2023]
Abstract
BACKGROUND Advancements in imaging and implantation technology have invited reexamination of the classic teaching that the human cochlea maintains uniform size across demographics. Yet, studies yield conflicting results and relatively few broad systematic reviews have examined cochlear size variation. PURPOSE The purpose of this study is to quantify cochlear variability across eight different measurement categories and suggest normative values and ranges for each with consideration of disease state and gender where possible. METHODS A systematic search was conducted up to October 1, 2022, using the search terms "Cochlea/anatomy and histology"[Mesh]) AND 'size'" with filters "Humans" and "English" across three databases (PubMed, CINAHL, Medline). Further inclusion criteria involved reporting of numerical measurements in any of the eight included categories. RESULTS Of the 625 articles manually reviewed for relevance by title and abstract, 91 were selected for full-text review and 33 met all eligibility criteria. 5,791 cochleae were included and weighted means and ranges were calculated: "A" value (defined as the distance from the round window, through the modiolus, to the oppsite lateral wall) = 9.23 mm (8.43-10.4 mm, n = 2559); cochlear duct length (CDL) = 33.04 mm (range 28.2-36.4 mm, n = 2252); cochlear height = 5.14 mm (2.8-6.9 mm, n = 2098); the basal turn lumen diameter = 2.09 mm (1.7-2.2 mm, n = 617); "B" value (defined as perpendicular to "A" value and in the same plane) = 6.52 mm (5.73-6.9 mm, n = 908); width of the basal turn = 6.4 mm (6.22-6.86 mm, n = 356); height of the basal turn = 1.96 mm (1.77-2.56 mm, n = 204); length of the basal turn 21.87 mm (21.03-22.5 mm, n = 384). CONCLUSION A notable size range exists across the eight different cochlear parameters considered and we provide normative values for each measurement. Females tend to have smaller CDL and "A" value than males and the sensorineural hearing loss patients had smaller CDL and "A" value but larger cochlear height than the general population.
Collapse
Affiliation(s)
| | | | - Anita Jeyakumar
- Department of Otolaryngology, Mercy Bon Secours, Youngstown, OH, 44512, USA
| |
Collapse
|
23
|
Geiger S, Iso-Mustajärvi M, Nauwelaers T, Avci E, Julkunen P, Linder P, Silvast T, Dietz A. Automatic electrode scalar location assessment after cochlear implantation using a novel imaging software. Sci Rep 2023; 13:12416. [PMID: 37524776 PMCID: PMC10390550 DOI: 10.1038/s41598-023-39275-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 07/22/2023] [Indexed: 08/02/2023] Open
Abstract
As of today, image-based assessment of cochlear implant electrode array location is not part of the clinical routine. Low resolution and contrast of computer tomography (CT) imaging, as well as electrode array artefacts, prevent visibility of intracochlear structures and result in low accuracy in determining location of the electrode array. Further, trauma assessment based on clinical-CT images requires a uniform image-based trauma scaling. Goal of this study was to evaluate the accuracy of a novel imaging software to detect electrode scalar location. Six cadaveric temporal bones were implanted with Advanced Bionics SlimJ and Mid-Scala electrode arrays. Clinical-CT scans were taken pre- and postoperatively. In addition, micro-CTs were taken post-operatively for validation. The electrode scalar location rating done by the software was compared to the rating of two experienced otosurgeons and the micro-CT images. A 3-step electrode scalar location grading scale (0 = electrode in scala tympani, 1 = interaction of electrode with basilar membrane/osseous spiral lamina, 2 = translocation of electrode into scala vestibuli) was introduced for the assessment. The software showed a high sensitivity of 100% and a specificity of 98.7% for rating the electrode location. The correlation between rating methods was strong (kappa > 0.890). The software gives a fast and reliable method of evaluating electrode scalar location for cone beam CT scans. The introduced electrode location grading scale was adapted for assessing clinical CT images.
Collapse
Affiliation(s)
- S Geiger
- Advanced Bionics, European Research Center, Hannover, Germany.
| | - M Iso-Mustajärvi
- Department of Otorhinolaryngology, Kuopio University Hospital, Kuopio, Finland
| | - T Nauwelaers
- Advanced Bionics, European Research Center, Hannover, Germany
| | - E Avci
- Advanced Bionics, European Research Center, Hannover, Germany
| | - P Julkunen
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Department of Clinical Neurophysiology, Kuopio University Hospital, Kuopio, Finland
| | - P Linder
- Department of Otorhinolaryngology, Kuopio University Hospital, Kuopio, Finland
| | - T Silvast
- SIB Labs, Dempartment of Technical Physics, University of Eastern Finland, Kuopio, Finland
| | - A Dietz
- Department of Otorhinolaryngology, Kuopio University Hospital, Kuopio, Finland
| |
Collapse
|
24
|
Hrncirik F, Roberts I, Sevgili I, Swords C, Bance M. Models of Cochlea Used in Cochlear Implant Research: A Review. Ann Biomed Eng 2023; 51:1390-1407. [PMID: 37087541 PMCID: PMC10264527 DOI: 10.1007/s10439-023-03192-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 03/20/2023] [Indexed: 04/24/2023]
Abstract
As the first clinically translated machine-neural interface, cochlear implants (CI) have demonstrated much success in providing hearing to those with severe to profound hearing loss. Despite their clinical effectiveness, key drawbacks such as hearing damage, partly from insertion forces that arise during implantation, and current spread, which limits focussing ability, prevent wider CI eligibility. In this review, we provide an overview of the anatomical and physical properties of the cochlea as a resource to aid the development of accurate models to improve future CI treatments. We highlight the advancements in the development of various physical, animal, tissue engineering, and computational models of the cochlea and the need for such models, challenges in their use, and a perspective on their future directions.
Collapse
Affiliation(s)
- Filip Hrncirik
- Cambridge Hearing Group, Cambridge, UK.
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK.
| | - Iwan Roberts
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Ilkem Sevgili
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Chloe Swords
- Cambridge Hearing Group, Cambridge, UK
- Department of Physiology, Development and Neurosciences, University of Cambridge, Cambridge, CB2 3DY, UK
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| |
Collapse
|
25
|
Fujiwara RJ, Ishiyama G, Lopez IA, Ishiyama A. Morphometric Analysis and Linear Measurements of the Scala Tympani and Implications in Cochlear Implant Electrodes. Otol Neurotol 2023; 44:e343-e349. [PMID: 36893208 PMCID: PMC10175138 DOI: 10.1097/mao.0000000000003848] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/10/2023]
Abstract
HYPOTHESIS The objective of this study was to perform detailed height and cross-sectional area measurements of the scala tympani in histologic sections of nondiseased human temporal bones and correlate them with cochlear implant electrode dimensions. BACKGROUND Previous investigations in scala tympani dimensions have used microcomputed tomography or casting modalities, which cannot be correlated directly with microanatomy visible on histologic specimens. METHODS Three-dimensional reconstructions of 10 archival human temporal bone specimens with no history of middle or inner ear disease were generated using hematoxylin and eosin histopathologic slides. At 90-degree intervals, the heights of the scala tympani at lateral wall, midscala, and perimodiolar locations were measured, along with cross-sectional area. RESULTS The vertical height of the scala tympani at its lateral wall significantly decreased from 1.28 to 0.88 mm from 0 to 180 degrees, and the perimodiolar height decreased from 1.20 to 0.85 mm. The cross-sectional area decreased from 2.29 (standard deviation, 0.60) mm 2 to 1.38 (standard deviation, 0.13) mm 2 from 0 to 180 degrees ( p = 0.001). After 360 degrees, the scala tympani shape transitioned from an ovoid to triangular shape, corresponding with a significantly decreased lateral height relative to perimodiolar height. Wide variability was observed among the cochlear implant electrode sizes relative to scala tympani measurements. CONCLUSION The present study is the first to conduct detailed measurements of heights and cross-sectional area of the scala tympani and the first to statistically characterize the change in its shape after the basal turn. These measurements have important implications in understanding locations of intracochlear trauma during insertion and electrode design.
Collapse
Affiliation(s)
- Rance J.T. Fujiwara
- David Geffen School of Medicine at UCLA, Department of Head and Neck Surgery, Los Angeles 90095
| | - Gail Ishiyama
- David Geffen School of Medicine at UCLA, Department of Neurology, Los Angeles 90095
| | - Ivan A. Lopez
- David Geffen School of Medicine at UCLA, Department of Head and Neck Surgery, Los Angeles 90095
| | - Akira Ishiyama
- David Geffen School of Medicine at UCLA, Department of Head and Neck Surgery, Los Angeles 90095
| |
Collapse
|
26
|
Söderqvist S, Sivonen V, Koivisto J, Aarnisalo A, Sinkkonen ST. Spread of the intracochlear electrical field: Implications for assessing electrode array location in cochlear implantation. Hear Res 2023; 434:108790. [PMID: 37196460 DOI: 10.1016/j.heares.2023.108790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 05/03/2023] [Accepted: 05/10/2023] [Indexed: 05/19/2023]
Abstract
The electrode-generated intracochlear electrical field (EF) spreads widely along the scala tympani surrounded by poorly-conducting tissue and it can be measured with monopolar transimpedance matrix (TIMmp). Bipolar TIM (TIMbp) allows estimations of local potential differences. With TIMmp, the correct alignment of the electrode array can be assessed, and TIMbp may be useful in more subtle evaluations of the electrode array's intracochlear location. In this temporal bone study, we investigated the effect of the cross-sectional scala area (SA) and the electrode-medial-wall distance (EMWD) on both TIMmp and TIMbp using three types of electrode arrays. Also, multiple linear regressions based on the TIMmp and TIMbp measurements were used to estimate the SA and EMWD. Six cadaver temporal bones were consecutively implanted with a lateral-wall electrode array (Slim Straight) and with two different precurved perimodiolar electrode arrays (Contour Advance and Slim Modiolar) for variation in EMWD. The bones were imaged with cone-beam computed tomography with simultaneous TIMmp and TIMbp measurements. The results from imaging and EF measurements were compared. SA increased from apical to basal direction (r = 0.96, p < 0.001). Intracochlear EF peak negatively correlated with SA (r = -0.55, p < 0.001) irrespective of the EMWD. The rate of the EF decay did not correlate with SA but it was faster in the proximity of the medial wall than in more lateral positions (r = 0.35, p < 0.001). For a linear comparison between the EF decaying proportionally to squared distance and anatomic dimensions, a square root of inverse TIMbp was applied and found to be affected by both SA and EMWD (r = 0.44 and r = 0.49, p < 0.001 for both). A regression model confirmed that together TIMmp and TIMbp can be used to estimate both SA and EMWD (R2 = 0.47 and R2 = 0.44, respectively, p < 0.001 for both). In TIMmp, EF peaks grow from basal to apical direction and EF decay is steeper in the proximity of the medial wall than in more lateral positions. Local potentials measured via TIMbp correlate with both SA and EMWD. Altogether, TIMmp and TIMbp can be used to assess the intracochlear and intrascalar position of the electrode array, and they may reduce the need for intra- and postoperative imaging in the future.
Collapse
Affiliation(s)
- Samuel Söderqvist
- Department of Otorhinolaryngology - Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, Helsinki 00130, Finland.
| | - Ville Sivonen
- Department of Otorhinolaryngology - Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, Helsinki 00130, Finland
| | - Juha Koivisto
- Department of Physics, University of Helsinki, Helsinki, Finland
| | - Antti Aarnisalo
- Department of Otorhinolaryngology - Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, Helsinki 00130, Finland
| | - Saku T Sinkkonen
- Department of Otorhinolaryngology - Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, Helsinki 00130, Finland
| |
Collapse
|
27
|
Müller-Graff FT, Voelker J, Kurz A, Hagen R, Neun T, Rak K. Accuracy of radiological prediction of electrode position with otological planning software and implications of high-resolution imaging. Cochlear Implants Int 2023; 24:144-154. [PMID: 36617441 DOI: 10.1080/14670100.2022.2159128] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
OBJECTIVES In cochlear implantation, preoperative prediction of electrode position has recently gained increasing attention. Currently, planning is usually done by multislice CT (MSCT). However, flat-panel volume CT (fpVCT) and its secondary reconstructions (fpVCTSECO) allow for more precise visualization of the cochlea. Combined with a newly developed otological planning software, the position of every single contact can be effectively predicted. In this study it was investigated how accurately radiological prediction forecasts the postoperative electrode localization and whether higher image resolution is advantageous. METHODS Utilizing otological planning software (OTOPLAN®) and different clinical imaging modalities (MSCT, fpVCT and fpVCTSECO) the electrode localization [angular insertion depth (AID)] and respective contact frequencies were predicted preoperatively and examined postoperatively. Furthermore, inter-electrode-distance (IED) and inter-electrode-frequency difference (IEFD) were evaluated postoperatively. RESULTS Measurements revealed a preoperative overestimation of AID. Corresponding frequencies were also miscalculated. Determination of IED and IEFD revealed discrepancies at the transition from the basal to the middle turn and round window to the basal turn. All predictions and discrepancies were lowest when using fpVCTSECO. CONCLUSION The postoperative electrode position can be predicted quite accurately using otological planning software. However, because of several potential misjudgments, high-resolution imaging, such as offered by fpVCTSECO, should be used pre- and postoperatively.
Collapse
Affiliation(s)
- Franz-Tassilo Müller-Graff
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| | - Johannes Voelker
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| | - Anja Kurz
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| | - Rudolf Hagen
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| | - Tilmann Neun
- Institute for Diagnostic and Interventional Neuroradiology, University of Wuerzburg, Wuerzburg, Germany
| | - Kristen Rak
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| |
Collapse
|
28
|
Kirk JR, Smyth D, Dueck WF. A new paradigm of hearing loss and preservation with cochlear implants: Learnings from fundamental studies and clinical research. Hear Res 2023; 433:108769. [PMID: 37120894 DOI: 10.1016/j.heares.2023.108769] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 02/18/2023] [Accepted: 04/15/2023] [Indexed: 05/02/2023]
Abstract
In 2010 Cochlear initiated a coordinated preclinical research program to identify the factors and underlying mechanisms of acoustic hearing loss following cochlear implantation and device use. At its inception the program was structured around several major hypotheses implicated in the loss of acoustic hearing. The understanding of causes evolved over the course of the program, leading to an increased appreciation of the role of the biological response in post-implant hearing loss. A systematic approach was developed which mapped the cochlear implant journey along a timeline that considers all events in an individual's hearing history. By evaluating the available data in this context, rather than by discrete hypothesis testing, causative and associated factors may be more readily detected. This approach presents opportunities for more effective research management and may aid in identifying new prospects for intervention. Many of the outcomes of the research program apply beyond preservation of acoustic hearing to factors important to overall cochlear health and considerations for future therapies.
Collapse
Affiliation(s)
- Jonathon R Kirk
- Cochlear Limited, 1 University Avenue, Macquarie University, NSW 2109, Australia.
| | - Daniel Smyth
- Cochlear Limited, 1 University Avenue, Macquarie University, NSW 2109, Australia
| | - Wolfram F Dueck
- Cochlear Limited, 1 University Avenue, Macquarie University, NSW 2109, Australia
| |
Collapse
|
29
|
Iso-Mustajärvi M, Silvast T, Heikka T, Tervaniemi J, Calixto R, Linder PH, Dietz A. Trauma After Cochlear Implantation: The Accuracy of Micro-Computed Tomography and Cone-Beam Fusion Computed Tomography Compared With Histology in Human Temporal Bones. Otol Neurotol 2023; 44:339-345. [PMID: 36843083 PMCID: PMC10022666 DOI: 10.1097/mao.0000000000003835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2023]
Abstract
HYPOTHESIS Micro-computed tomography (micro-CT) and cone-beam computed tomography (CBCT), in conjunction with the image fusion technique, may provide similar results for trauma assessment after cochlear implantation, with respect to the trauma evaluation in preclinical cochlear implant (CI) studies, as the histology. BACKGROUND Before clinical use, novel cochlear implant (CI) designs are tested in temporal bone (TB) studies for usability and risk evaluation. The criterion standard for evaluating intracochlear insertion trauma and electrode location has historically been with histological samples. Progress of modern imaging technology has created alternatives to classic histology. This study compares the micro-CT and CBCT fusion images between histological samples in a preclinical CI study. METHODS Fourteen freshly frozen TBs were inserted with a lateral wall research CI electrode. All TBs were scanned with CBCT preoperatively and postoperatively. After insertion, the TBs were prepared for micro-CT and histology. Twelve TBs underwent first a micro-CT and then the histological process. The CBCTs were used for image fusion, and all three different methods were used for intracochlear trauma evaluation. The results were compared between methods. RESULTS There were 4 of 14 translocations detected with the fusion image method and 3 of 12 with the micro-CT and histology. When compared, the trauma grades converged and were not statistically significant. CONCLUSION The trauma grading based on micro-CT is comparable to the histology. The image fusion technique based on CBCT is less accurate because it relies on an empirical assumption of the basal membrane localization, but it is clinically applicable.
Collapse
Affiliation(s)
| | - Tuomo Silvast
- SIB Labs Infrastructure Unit, Faculty of Science and Forestry, University of Eastern Finland
| | - Tuomas Heikka
- Department of Otorhinolaryngology, Kuopio University Hospital
| | - Jyrki Tervaniemi
- Department of Radiology, Kuopio University Hospital, Kuopio, Finland
| | | | - Pia H. Linder
- Department of Otorhinolaryngology, Kuopio University Hospital
| | - Aarno Dietz
- Department of Otorhinolaryngology, Kuopio University Hospital
| |
Collapse
|
30
|
Starovoyt A, Shaheen E, Putzeys T, Kerckhofs G, Politis C, Wouters J, Verhaert N. Anatomically and mechanically accurate scala tympani model for electrode insertion studies. Hear Res 2023; 430:108707. [PMID: 36773540 DOI: 10.1016/j.heares.2023.108707] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 11/25/2022] [Accepted: 01/24/2023] [Indexed: 01/26/2023]
Abstract
The risk of insertion trauma in cochlear implantation is determined by the interplay between individual cochlear anatomy and electrode insertion mechanics. Whereas patient anatomy cannot be changed, new surgical techniques, devices for cochlear monitoring, drugs, and electrode array designs are continuously being developed and tested, to optimize the insertion mechanics and prevent trauma. Preclinical testing of these developments is a crucial step in feasibility testing and optimization for clinical application. Human cadaveric specimens allow for the best simulation of an intraoperative setting. However, their availability is limited and it is not possible to conduct repeated, controlled experiments on the same sample. A variety of artificial cochlear models have been developed for electrode insertion studies, but none of them were both anatomically and mechanically representative for surgical insertion into an individual cochlea. In this study, we developed anatomically representative models of the scala tympani for surgical insertion through the round window, based on microCT images of individual human cochleae. The models were produced in transparent material using commonly-available 3D printing technology at a desired scale. The anatomical and mechanical accuracy of the produced models was validated by comparison with human cadaveric cochleae. Mechanical evaluation was performed by recording insertion forces, counting the number of inserted electrodes and grading tactile feedback during manual insertion of a straight electrode by experienced cochlear implant surgeons. Our results demonstrated that the developed models were highly representative for the anatomy of the original cochleae and for the insertion mechanics in human cadaveric cochleae. The individual anatomy of the produced models had a significant impact on the insertion mechanics. The described models have a promising potential to accelerate preclinical development and testing of atraumatic insertion techniques, reducing the need for human cadaveric material. In addition, realistic models of the cochlea can be used for surgical training and preoperative planning of patient-tailored cochlear implantation surgery.
Collapse
Affiliation(s)
- Anastasiya Starovoyt
- Research Group Experimental Oto-Rhino-Laryngology, Department of Neurosciences, KU Leuven, University of Leuven, Leuven, Belgium; Leuven Brain Institute, Department of Neurosciences, KU Leuven, 3000 Leuven, Belgium
| | - Eman Shaheen
- OMFS IMPATH Research Group, Department of Imaging and Pathology, KU Leuven, University of Leuven, Leuven, Belgium; Department of Oral and Maxillofacial Surgery, UZ Leuven, University Hospitals Leuven, Leuven, Belgium
| | - Tristan Putzeys
- Research Group Experimental Oto-Rhino-Laryngology, Department of Neurosciences, KU Leuven, University of Leuven, Leuven, Belgium; Leuven Brain Institute, Department of Neurosciences, KU Leuven, 3000 Leuven, Belgium; Laboratory for Soft Matter and Biophysics, Department of Physics and Astronomy, KU Leuven, University of Leuven, Leuven, Belgium
| | - Greet Kerckhofs
- Biomechanics lab, Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium; Department of Materials Engineering, KU Leuven, University of Leuven, Leuven, Belgium; IREC, Institute of Experimental and Clinical Research, UCLouvain, Woluwé-Saint-Lambert, Belgium; Prometheus, Division of Skeletal Tissue Engineering, KU Leuven, University of Leuven, Leuven, Belgium
| | - Constantinus Politis
- OMFS IMPATH Research Group, Department of Imaging and Pathology, KU Leuven, University of Leuven, Leuven, Belgium; Department of Oral and Maxillofacial Surgery, UZ Leuven, University Hospitals Leuven, Leuven, Belgium
| | - Jan Wouters
- Research Group Experimental Oto-Rhino-Laryngology, Department of Neurosciences, KU Leuven, University of Leuven, Leuven, Belgium; Leuven Brain Institute, Department of Neurosciences, KU Leuven, 3000 Leuven, Belgium
| | - Nicolas Verhaert
- Research Group Experimental Oto-Rhino-Laryngology, Department of Neurosciences, KU Leuven, University of Leuven, Leuven, Belgium; Leuven Brain Institute, Department of Neurosciences, KU Leuven, 3000 Leuven, Belgium; Department of Otorhinolaryngology, Head and Neck Surgery, UZ Leuven, University Hospitals of Leuven, Leuven, Belgium.
| |
Collapse
|
31
|
Schurzig D, Repp F, Timm ME, Batsoulis C, Lenarz T, Kral A. Virtual cochlear implantation for personalized rehabilitation of profound hearing loss. Hear Res 2023; 429:108687. [PMID: 36638762 DOI: 10.1016/j.heares.2022.108687] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 12/09/2022] [Accepted: 12/26/2022] [Indexed: 12/28/2022]
Abstract
In cochlear implantation, current preoperative planning procedures allow for estimating how far a specific implant will reach into the inner ear of the patient, which is important to optimize hearing preservation and speech perception outcomes. Here we report on the development of a methodology that goes beyond current planning approaches: the proposed model does not only estimate specific outcome parameters but allows for entire, three-dimensional virtual implantations of patient-specific cochlear anatomies with different types of electrode arrays. The model was trained based on imaging datasets of 186 human cochleae, which contained 171 clinical computer tomographies (CTs) of actual cochlear implant patients as well as 15 high-resolution micro-CTs of cadaver cochleae to also reconstruct the refined intracochlear structures not visible in clinical imaging. The model was validated on an independent dataset of 141 preoperative and postoperative clinical CTs of cochlear implant recipients and outperformed all currently available planning approaches, not only in terms of accuracy but also regarding the amount of information that is available prior to the actual implantation.
Collapse
Affiliation(s)
- Daniel Schurzig
- Institute of AudioNeuroTechnology & Department of Experimental Otology, ENT Department, Hannover Medical School, Hannover, Germany; MED-EL Research Center, Hannover, Germany.
| | | | - Max E Timm
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | | | - Thomas Lenarz
- Institute of AudioNeuroTechnology & Department of Experimental Otology, ENT Department, Hannover Medical School, Hannover, Germany; Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Andrej Kral
- Institute of AudioNeuroTechnology & Department of Experimental Otology, ENT Department, Hannover Medical School, Hannover, Germany; Department of Otolaryngology, Hannover Medical School, Hannover, Germany; Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| |
Collapse
|
32
|
Ishiyama P, Ishiyama G, Lopez IA, Ishiyama A. Archival Human Temporal Bone: Anatomical and Histopathological Studies of Cochlear Implantation. J Pers Med 2023; 13:352. [PMID: 36836587 PMCID: PMC9959196 DOI: 10.3390/jpm13020352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/12/2023] [Accepted: 02/14/2023] [Indexed: 02/22/2023] Open
Abstract
Since being FDA approved in 1984, cochlear implantation has been used successfully to restore hearing in those with severe to profound hearing loss with broader applications including single-sided deafness, the use of hybrid electroacoustic stimulation, and implantation at all extremes of age. Cochlear implants have undergone multiple changes in the design aimed at improving the processing technology, while simultaneously minimizing the surgical trauma and foreign body reaction. The following review examines the human temporal bone studies regarding the anatomy of the human cochlea and how the anatomy relates to cochlear implant design, the factors related to complications after implantation, and the predictors of new tissue formation and osteoneogenesis. Histopathological studies are reviewed which aim to understand the potential implications of the effects of new tissue formation and inflammation following implantation.
Collapse
Affiliation(s)
- Paul Ishiyama
- Department of Head and Neck Surgery, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA
| | - Gail Ishiyama
- Department of Neurology, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA
| | - Ivan A. Lopez
- Department of Head and Neck Surgery, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA
| | - Akira Ishiyama
- Department of Head and Neck Surgery, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA
| |
Collapse
|
33
|
Human cochlear microstructures at risk of electrode insertion trauma, elucidated in 3D with contrast-enhanced microCT. Sci Rep 2023; 13:2191. [PMID: 36750646 PMCID: PMC9905077 DOI: 10.1038/s41598-023-29401-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 02/03/2023] [Indexed: 02/09/2023] Open
Abstract
Cochlear implant restores hearing loss through electrical stimulation of the hearing nerve from within the cochlea. Unfortunately, surgical implantation of this neuroprosthesis often traumatizes delicate intracochlear structures, resulting in loss of residual hearing and compromising hearing in noisy environments and appreciation of music. To avoid cochlear trauma, insertion techniques and devices have to be adjusted to the cochlear microanatomy. However, existing techniques were unable to achieve a representative visualization of the human cochlea: classical histology damages the tissues and lacks 3D perspective; standard microCT fails to resolve the cochlear soft tissues; and previously used X-ray contrast-enhancing staining agents are destructive. In this study, we overcame these limitations by performing contrast-enhanced microCT imaging (CECT) with a novel polyoxometalate staining agent Hf-WD POM. With Hf-WD POM-based CECT, we achieved nondestructive, high-resolution, simultaneous, 3D visualization of the mineralized and soft microstructures in fresh-frozen human cochleae. This enabled quantitative analysis of the true intracochlear dimensions and led to anatomical discoveries, concerning surgically-relevant microstructures: the round window membrane, the Rosenthal's canal and the secondary spiral lamina. Furthermore, we demonstrated that Hf-WD POM-based CECT enables quantitative assessment of these structures as well as their trauma.
Collapse
|
34
|
Hussain R, Frater A, Calixto R, Karoui C, Margeta J, Wang Z, Hoen M, Delingette H, Patou F, Raffaelli C, Vandersteen C, Guevara N. Anatomical Variations of the Human Cochlea Using an Image Analysis Tool. J Clin Med 2023; 12:jcm12020509. [PMID: 36675438 PMCID: PMC9867191 DOI: 10.3390/jcm12020509] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 12/30/2022] [Accepted: 01/04/2023] [Indexed: 01/11/2023] Open
Abstract
Understanding cochlear anatomy is crucial for developing less traumatic electrode arrays and insertion guidance for cochlear implantation. The human cochlea shows considerable variability in size and morphology. This study analyses 1000+ clinical temporal bone CT images using a web-based image analysis tool. Cochlear size and shape parameters were obtained to determine population statistics and perform regression and correlation analysis. The analysis revealed that cochlear morphology follows Gaussian distribution, while cochlear dimensions A and B are not well-correlated to each other. Additionally, dimension B is more correlated to duct lengths, the wrapping factor and volume than dimension A. The scala tympani size varies considerably among the population, with the size generally decreasing along insertion depth with dimensional jumps through the trajectory. The mean scala tympani radius was 0.32 mm near the 720° insertion angle. Inter-individual variability was four times that of intra-individual variation. On average, the dimensions of both ears are similar. However, statistically significant differences in clinical dimensions were observed between ears of the same patient, suggesting that size and shape are not the same. Harnessing deep learning-based, automated image analysis tools, our results yielded important insights into cochlear morphology and implant development, helping to reduce insertion trauma and preserving residual hearing.
Collapse
Affiliation(s)
- Raabid Hussain
- Research & Technology, Oticon Medical, 06220 Vallauris, France
- Correspondence:
| | - Attila Frater
- Research & Technology, Oticon Medical, 06220 Vallauris, France
| | - Roger Calixto
- Research & Technology, Oticon Medical, 06220 Vallauris, France
| | - Chadlia Karoui
- Clinical Evidence Department, Oticon Medical, 06220 Vallauris, France
| | - Jan Margeta
- Research and Development, KardioMe, 01851 Nova Dubnica, Slovakia
| | - Zihao Wang
- Epione Team, Inria, Université Côte d’Azur, 06902 Sophia Antipolis, France
| | - Michel Hoen
- Clinical Evidence Department, Oticon Medical, 06220 Vallauris, France
| | - Herve Delingette
- Epione Team, Inria, Université Côte d’Azur, 06902 Sophia Antipolis, France
| | - François Patou
- Research & Technology, Oticon Medical, 06220 Vallauris, France
| | - Charles Raffaelli
- Institut Universitaire de la Face et du Cou, Nice, Centre Hospitalier Universitaire de Nice, Université Côte d’Azur, 06100 Nice, France
| | - Clair Vandersteen
- Institut Universitaire de la Face et du Cou, Nice, Centre Hospitalier Universitaire de Nice, Université Côte d’Azur, 06100 Nice, France
| | - Nicolas Guevara
- Institut Universitaire de la Face et du Cou, Nice, Centre Hospitalier Universitaire de Nice, Université Côte d’Azur, 06100 Nice, France
| |
Collapse
|
35
|
Bester C, Collins A, Razmovski T, Weder S, Briggs RJ, Wei B, Zakaria AF, Gerard JM, Mitchell-Innes A, Tykocinski M, Kennedy R, Iseli C, Dahm M, Ellul S, O'Leary S. Electrocochleography triggered intervention successfully preserves residual hearing during cochlear implantation: Results of a randomised clinical trial. Hear Res 2022; 426:108353. [PMID: 34600798 DOI: 10.1016/j.heares.2021.108353] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 08/19/2021] [Accepted: 09/15/2021] [Indexed: 12/16/2022]
Abstract
BACKGROUND Preservation of natural hearing during cochlear implantation is associated with improved speech outcomes, however more than half of implant recipients lose this hearing. Real-time electrophysiological monitoring of cochlear output during implantation, made possible by recording electrocochleography using the electrodes on the cochlear implant, has shown promise in predicting hearing preservation. Sudden drops in the amplitude of the cochlear microphonic (CM) have been shown to predict more severe hearing losses. Here, we report on a randomized clinical trial investigating whether immediate surgical intervention triggered by these drops can save residual hearing. METHODS A single-blinded placebo-controlled trial of surgical intervention triggered when CM amplitude dropped by at least 30% of a prior maximum amplitude during cochlear implantation. Intraoperative electrocochleography was recorded in 60 adults implanted with Cochlear Ltd's Thin Straight Electrode, half randomly assigned to a control group and half to an interventional group. The surgical intervention was to withdraw the electrode in ½-mm steps to recover CM amplitude. The primary outcome was hearing preservation 3 months following implantation, with secondary outcomes of speech-in-noise reception thresholds by group or CM outcome, and depth of implantation. RESULTS Sixty patients were recruited; neither pre-operative audiometry nor speech reception thresholds were significantly different between groups. Post-operatively, hearing preservation was significantly better in the interventional group. This was the case in absolute difference (median of 30 dB for control, 20 dB for interventional, χ² = 6.2, p = .013), as well as for relative difference (medians of 66% for the control, 31% for the interventional, χ² = 5.9, p = .015). Speech-in-noise reception thresholds were significantly better in patients with no CM drop at any point during insertion compared with patients with a CM drop; however, those with successfully recovered CMs after an initial drop were not significantly different (median gain required for speech reception score of 50% above noise of 6.9 dB for no drop, 8.6 for recovered CM, and 9.8 for CM drop, χ² = 6.8, p = .032). Angular insertion depth was not significantly different between control and interventional groups. CONCLUSIONS This is the first demonstration that surgical intervention in response to intraoperative hearing monitoring can save residual hearing during cochlear implantation.
Collapse
Affiliation(s)
- Christofer Bester
- The University of Melbourne, Department of Surgery and The Royal Victorian Eye and Ear Hospital.
| | - Aaron Collins
- The University of Melbourne, Department of Surgery and The Royal Victorian Eye and Ear Hospital
| | - Tayla Razmovski
- The University of Melbourne, Department of Surgery and The Royal Victorian Eye and Ear Hospital
| | - Stefan Weder
- The University of Melbourne, Department of Surgery and The Royal Victorian Eye and Ear Hospital; Department of ENT, Head and Neck Surgery, University Hospital, Bern, Switzerland
| | | | | | - Atiqah Farah Zakaria
- The University of Melbourne, Department of Surgery and The Royal Victorian Eye and Ear Hospital; Department of Otorhinolaryngology, University Putra Malaysia, Malaysia
| | - Jean-Marc Gerard
- The University of Melbourne, Department of Surgery and The Royal Victorian Eye and Ear Hospital; Department of ENT, RVEEH
| | - Alistair Mitchell-Innes
- The University of Melbourne, Department of Surgery and The Royal Victorian Eye and Ear Hospital; Department of ENT, RVEEH
| | | | | | | | | | | | - Stephen O'Leary
- The University of Melbourne, Department of Surgery and The Royal Victorian Eye and Ear Hospital; Department of ENT, RVEEH.
| |
Collapse
|
36
|
Hrncirik F, Roberts IV, Swords C, Christopher PJ, Chhabu A, Gee AH, Bance ML. Impact of Scala Tympani Geometry on Insertion Forces during Implantation. BIOSENSORS 2022; 12:999. [PMID: 36354508 PMCID: PMC9688204 DOI: 10.3390/bios12110999] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 10/25/2022] [Accepted: 11/05/2022] [Indexed: 05/07/2023]
Abstract
(1) Background: During a cochlear implant insertion, the mechanical trauma can cause residual hearing loss in up to half of implantations. The forces on the cochlea during the insertion can lead to this mechanical trauma but can be highly variable between subjects which is thought to be due to differing anatomy, namely of the scala tympani. This study presents a systematic investigation of the influence of different geometrical parameters of the scala tympani on the cochlear implant insertion force. The influence of these parameters on the insertion forces were determined by testing the forces within 3D-printed, optically transparent models of the scala tympani with geometric alterations. (2) Methods: Three-dimensional segmentations of the cochlea were characterised using a custom MATLAB script which parametrised the scala tympani model, procedurally altered the key shape parameters (e.g., the volume, vertical trajectory, curvature, and cross-sectional area), and generated 3D printable models that were printed using a digital light processing 3D printer. The printed models were then attached to a custom insertion setup that measured the insertion forces on the cochlear implant and the scala tympani model during a controlled robotic insertion. (3) Results: It was determined that the insertion force is largely unaffected by the overall size, curvature, vertical trajectory, and cross-sectional area once the forces were normalised to an angular insertion depth. A Capstan-based model of the CI insertion forces was developed and matched well to the data acquired. (4) Conclusion: By using accurate 3D-printed models of the scala tympani with geometrical alterations, it was possible to demonstrate the insensitivity of the insertion forces to the size and shape of the scala tympani, after controlling for the angular insertion depth. This supports the Capstan model of the cochlear implant insertion force which predicts an exponential growth of the frictional force with an angular insertion depth. This concludes that the angular insertion depth, rather than the length of the CI inserted, should be the major consideration when evaluating the insertion force and associated mechanical trauma caused by cochlear implant insertion.
Collapse
Affiliation(s)
- Filip Hrncirik
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK
| | - Iwan V. Roberts
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK
| | - Chloe Swords
- Cambridge Hearing Group, Cambridge, UK
- Department of Physiology, Development and Neurosciences, University of Cambridge, Cambridge CB2 3DY, UK
| | | | - Akil Chhabu
- Clinical School, University of Cambridge, Cambridge CB2 0SP, UK
| | - Andrew H. Gee
- Department of Physiology, Development and Neurosciences, University of Cambridge, Cambridge CB2 3DY, UK
| | - Manohar L. Bance
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK
| |
Collapse
|
37
|
Alshalan A, Abdelsamad Y, Assiri M, Alsanosi A. Cochlear Implantation: The Variation in Cochlear Height. EAR, NOSE & THROAT JOURNAL 2022:1455613221134860. [PMID: 36251258 DOI: 10.1177/01455613221134860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
This study aimed to identify the association between different cochlear metrics, including the basal turn diameter (A-value), the basal turn width (B-value), and the height of the cochlea (H-value). We also reported an association between H-value and hearing outcomes with cochlear implants (CI). This is a retrospective study that included all patients who underwent CI procedures between 2012 and 2018 at a tertiary center and have; preoperative high-resolution computed tomography (CT), normal cochlea, postoperative follow-up duration of at least 2 years, scores of the category auditory performance II (CAP-II), and speech intelligibility rating (SIR) scales. A total of 65 ears implanted with CI in 46 patients (24 boys and 20 girls; mean age of 7 (±10) years) fulfilled the inclusion criteria. We found significant positive correlations between A vs B, A vs H, and B vs H (P-value = 0.008, 0.018, and 0.0039, respectively). We also found a significant positive relationship between A, B, and H values and cochlear duct length (CDL) (P-value < 0.0001, 0.008, and 0.018, respectively). Finally, the H-value was significantly correlated with the SIR (P-value = 0.027). However, its correlation with the CAP score was not statistically significant (P-value = 0.62). Cochlear height significantly correlated with CDL and the other cochlear parameters. The variation in cochlear height can also affect speech outcomes in patients undergoing CI. Therefore, the H-value together with the other cochlear metrics should be adequately assessed preoperatively in CI patients.
Collapse
Affiliation(s)
- Afrah Alshalan
- Department of Otolaryngology, Neurotology & Lateral Skull Base Surgery, King Abdullah Ear Specialist Center (KAESC), King Saud University, Riyadh, Saudi Arabia
| | | | - Majed Assiri
- Department of Otolaryngology, Neurotology & Lateral Skull Base Surgery, King Abdullah Ear Specialist Center (KAESC), King Saud University, Riyadh, Saudi Arabia
| | - Abdulrahman Alsanosi
- King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
38
|
Salkim E, Zamani M, Jiang D, Saeed SR, Demosthenous A. Insertion Guidance Based on Impedance Measurements of a Cochlear Electrode Array. Front Comput Neurosci 2022; 16:862126. [PMID: 35814346 PMCID: PMC9260075 DOI: 10.3389/fncom.2022.862126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 05/18/2022] [Indexed: 11/30/2022] Open
Abstract
The cochlear implantable neuromodulator provides substantial auditory perception to those with severe or profound impaired hearing. Correct electrode array positioning in the cochlea is one of the important factors for quality hearing, and misplacement may lead to additional injury to the cochlea. Visual inspection of the progress of electrode insertion is limited and mainly relies on the surgeon's tactile skills, and there is a need to detect in real-time the electrode array position in the cochlea during insertion. The available clinical measurement presently provides very limited information. Impedance measurement may be used to assist with the insertion of the electrode array. Using computational modeling of the cochlea, and its local tissue layers merging with the associated neuromodulator electrode array parameters, the impedance variations at different insertion depths and the proximities to the cochlea walls have been analyzed. In this study, an anatomical computational model of the temporal region of a patient is used to derive the relationship between impedance variations and the electrode proximity to the cochlea wall and electrode insertion depth. The aim was to examine whether the use of electrode impedance variations can be an effective marker of electrode proximity and electrode insertion depth. The proposed anatomical model simulates the quasi-static electrode impedance variations at different selected points but at considerable computation cost. A much less computationally intensive geometric model (~1/30) provided comparative impedance measurements with differences of <2%. Both use finite element analysis over the entire cross-section area of the scala tympani. It is shown that the magnitude of the impedance varies with both electrode insertion depth and electrode proximity to the adjacent anatomical layers (e.g., cochlea wall). In particular, there is a 1,400% increase when the electrode array is moved very close to the cochlea wall. This may help the surgeon to find the optimal electrode position within the scala tympani by observation of such impedance characteristics. The misplacement of the electrode array within the scala tympani may be eliminated by using the impedance variation metric during electrode array insertion if the results are validated with an experimental study.
Collapse
Affiliation(s)
- Enver Salkim
- Department of Electronic and Electrical Engineering, University College London (UCL), London, United Kingdom
- Department of Electronic and Electrical Engineering, Biomedical Device Technology Group, Muş Alparslan University, Muş, Turkey
- *Correspondence: Enver Salkim
| | - Majid Zamani
- Department of Electronic and Electrical Engineering, University College London (UCL), London, United Kingdom
| | - Dai Jiang
- Department of Electronic and Electrical Engineering, University College London (UCL), London, United Kingdom
| | | | - Andreas Demosthenous
- Department of Electronic and Electrical Engineering, University College London (UCL), London, United Kingdom
| |
Collapse
|
39
|
Greisiger R, Heldahl MG, Myhrum M, Sørensen TM, Dammerud JJ, Rasmussen K, Korslund H, Bunne M, Jablonski GE. Effect of Proximity to the Modiolus for the Cochlear CI532 Slim Modiolar Electrode Array on Evoked Compound Action Potentials and Programming Levels. Audiol Neurootol 2022; 27:397-405. [PMID: 35504247 DOI: 10.1159/000524256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Accepted: 03/09/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND The first surgeries with CI532 showed an effect of the proximity of the electrode to the modiolus on the Evoked Compound Action Potentials (ECAPs). OBJECTIVES Objectives of the study were to investigate the effect of the "pullback" procedure on intraoperative ECAP responses in three different electrode array positions and additionally to compare behavioral thresholds with the thresholds obtained in a group of patients using the standard insertion. The hypothesis of this study is that pullback will cause lower ECAPs and behavioral thresholds. PATIENTS The study included 40 patients, 20 in the pullback insertion group and 20 in the standard insertion group (without pullback). METHOD During insertion of the CI532 electrode array, ECAP was performed in three different positions for the pullback group: at initial insertion, at over-insertion, and after pullback. Insertion was monitored by fluoroscopy. In the standard group, ECAP was performed at the initial position, which is also the final position. ECAP thresholds (T-ECAPs) were compared within subjects at the initial and the final position in the pullback group and between groups in the final positions of the pullback and standard groups. Programming levels (C- and T-levels) were compared between the two groups 1 year after switch-on. RESULTS Intraoperative measurements pullback shows lower average T-ECAPs after pullback compared to thresholds in initial position. Comparison of intraoperative T-ECAPs at the final positions showed no statistically significant difference between the pullback group and the standard insertion group. Furthermore, 1 year after switch-on there was no statistically significant difference in C- and T-levels between the two groups. CONCLUSION The pullback maneuver of the CI532 electrode array after an over-insertion gave significantly lower T-ECAPs compared to the thresholds at the initial position. However, the between-groups analysis of pullback and standard insertion showed neither significantly different T-ECAPs nor different programming levels. Because T-ECAPs and programming levels vary considerably between subjects, large groups are required to detect differences between groups. Additionally, the effect pullback technique to preserving the residual hearing is not known yet.
Collapse
Affiliation(s)
- Ralf Greisiger
- Department of Otorhinolaryngology, Oslo University Hospital, Oslo, Norway
| | | | - Marte Myhrum
- University of Oslo, Institute of Clinical Medicine, Oslo, Norway
| | | | | | - Kjell Rasmussen
- Department of Otorhinolaryngology, Oslo University Hospital, Oslo, Norway
| | - Hilde Korslund
- Intervention Centre, Oslo University Hospital, Oslo, Norway
| | - Marie Bunne
- Department of Otorhinolaryngology, Oslo University Hospital, Oslo, Norway
| | - Greg Eigner Jablonski
- Department of Otorhinolaryngology, Oslo University Hospital, Oslo, Norway.,University of Oslo, Institute of Clinical Medicine, Oslo, Norway
| |
Collapse
|
40
|
Sismono F, Leblans M, Mancini L, Veneziano A, Zanini F, Dirckx J, Bernaerts A, de Foer B, Offeciers E, Zarowski A. 3D-localisation of cochlear implant electrode contacts in relation to anatomical structures from in vivo cone-beam computed tomography. Hear Res 2022; 426:108537. [DOI: 10.1016/j.heares.2022.108537] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 03/18/2022] [Accepted: 05/23/2022] [Indexed: 12/11/2022]
|
41
|
Buechner A, Bardt M, Haumann S, Geissler G, Salcher R, Lenarz T. Clinical experiences with intraoperative electrocochleography in cochlear implant recipients and its potential to reduce insertion trauma and improve postoperative hearing preservation. PLoS One 2022; 17:e0266077. [PMID: 35452461 PMCID: PMC9032378 DOI: 10.1371/journal.pone.0266077] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 03/14/2022] [Indexed: 11/18/2022] Open
Abstract
Access to low-frequency acoustic information in cochlear implant patients leads to better speech understanding in noise. Electrocochleography (ECochG) can provide real-time feedback about the health of the cochlea during the insertion process with the potential to reduce insertion trauma. We describe our experiences of using this technique. Data from 47 adult subjects with measurable residual hearing and an Advanced Bionics (Valencia, CA) SlimJ (46) or MidScala (1) electrode array were analyzed. ECochGs were recorded intraoperatively via the implant. The surgeon adjusted the course of the electrode insertion based on drops in the ECochG. The final array position was assessed using postoperative imaging and pure tone thresholds were measured before and after surgery. Three different patterns of ECochG response amplitude were observed: Growth, Fluctuating and Total Loss. Subjects in the growth group showed the smallest postoperative hearing loss. However, the group with fluctuating amplitudes showed no meaningful correlation between the ECochG responses and the postoperative hearing loss, indicating that amplitude alone is insufficient for detecting damage. Considering the phase of the signal additionally to the amplitude and reclassifying the data by both the phase and amplitude of the response into three groups Type I–Type III produced statistically significant correlations between postoperative hearing loss and the grouping based on amplitude and phase respectively. We showed significantly better hearing preservation for Type I (no drop in amplitude) and Type II (drop with a concurrent phase shift), while Type III (drop without concurrent phase shift) had more surgery induced hearing loss. ECochG potentials measured through the implant could provide valuable feedback during the electrode insertion. Both the amplitude and phase of the ECochG response are important to consider. More data needs to be evaluated to better understand the impact of the different signal components to design an automated system to alert the surgeon ahead of damaging the cochlea.
Collapse
Affiliation(s)
- Andreas Buechner
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- * E-mail:
| | - Michael Bardt
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Sabine Haumann
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Gunnar Geissler
- European Research Center, Advanced Bionics GmbH, Hannover, Germany
| | - Rolf Salcher
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| |
Collapse
|
42
|
Variations in microanatomy of the human modiolus require individualized cochlear implantation. Sci Rep 2022; 12:5047. [PMID: 35322066 PMCID: PMC8943032 DOI: 10.1038/s41598-022-08731-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 03/10/2022] [Indexed: 11/09/2022] Open
Abstract
Cochlear variability is of key importance for the clinical use of cochlear implants, the most successful neuroprosthetic device that is surgically placed into the cochlear scala tympani. Despite extensive literature on human cochlear variability, few information is available on the variability of the modiolar wall. In the present study, we analyzed 108 corrosion casts, 95 clinical cone beam computer tomographies (CTs) and 15 µCTs of human cochleae and observed modiolar variability of similar and larger extent than the lateral wall variability. Lateral wall measures correlated with modiolar wall measures significantly. ~ 49% of the variability had a common cause. Based on these data we developed a model of the modiolar wall variations and related the model to the design of cochlear implants aimed for perimodiolar locations. The data demonstrate that both the insertion limits relevant for lateral wall damage (approximate range of 4–9 mm) as well as the dimensions required for optimal perimodiolar placement of the electrode (the point of release from the straightener; approximate range of 2–5mm) are highly interindividually variable. The data demonstrate that tip fold-overs of preformed implants likely result from the morphology of the modiolus (with radius changing from base to apex), and that optimal cochlear implantation of perimodiolar arrays cannot be guaranteed without an individualized surgical technique.
Collapse
|
43
|
Proteome profile of patients with excellent and poor speech intelligibility after cochlear implantation: Can perilymph proteins predict performance? PLoS One 2022; 17:e0263765. [PMID: 35239655 PMCID: PMC8893673 DOI: 10.1371/journal.pone.0263765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 01/26/2022] [Indexed: 11/20/2022] Open
Abstract
Modern proteomic analysis and reliable surgical access to gain liquid inner ear biopsies have enabled in depth molecular characterization of the cochlea microenvironment. In order to clarify whether the protein composition of the perilymph can provide new insights into individual hearing performance after cochlear implantation (CI), computational analysis in correlation to clinical performance after CI were performed based on the proteome profile derived from perilymph samples (liquid biopsies). Perilymph samples from cochlear implant recipients have been analyzed by mass spectrometry (MS). The proteins were identified using the shot-gun proteomics method and quantified and analyzed using Max Quant, Perseus and IPA software. A total of 75 perilymph samples from 68 (adults and children) patients were included in the analysis. Speech perception data one year after implantation were available for 45 patients and these were used for subsequent analysis. According to their hearing performance, patients with excellent (n = 22) and poor (n = 14) performance one year after CI were identified and used for further analysis. The protein composition and statistically significant differences in the two groups were detected by relative quantification of the perilymph proteins. With this procedure, a selection of 287 proteins were identified in at least eight samples in both groups. In the perilymph of the patients with excellent and poor performance, five and six significantly elevated proteins were identified respectively. These proteins seem to be involved in different immunological processes in excellent and poor performer. Further analysis on the role of specific proteins as predictors for poor or excellent performance among CI recipients are mandatory. Combinatory analysis of molecular inner ear profiles and clinical performance data using bioinformatics analysis may open up new possibilities for patient stratification. The impact of such prediction algorithms on diagnosis and treatment needs to be established in further studies.
Collapse
|
44
|
Intracochlear New Fibro-Ossification and Neuronal Degeneration Following Cochlear Implant Electrode Translocation: Long-Term Histopathological Findings in Humans. Otol Neurotol 2022; 43:e153-e164. [PMID: 35015749 DOI: 10.1097/mao.0000000000003402] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
OBJECTIVE We aim to assess the histopathology of human temporal bones (TBs) with evidence of cochlear implantation (CI) electrode scalar translocation. STUDY DESIGN Otopathology study. SETTING Otopathology laboratory. PATIENTS TBs from patients who had a history of CI and histopathological evidence of interscalar translocation. Specimens with electrode placed entirely within the ST served as controls. INTERVENTION Histopathological assessment of human TBs. MAIN OUTCOME MEASURES TBs from each patient were harvested postmortem and histologically analyzed for intracochlear changes in the context of CI electrode translocation and compared to controls. Intracochlear new fibro-ossification, and spiral ganglion neuron (SGN) counts were assessed. Postoperative word recognition scores (WRS) were also compared. RESULTS Nineteen human TBs with electrode translocation and eight controls were identified. The most common site of translocation was the ascending limb of the basal turn (n = 14 TBs). The average angle of insertion at the point of translocation was 159° ± 79°. Eighteen translocated cases presented moderate fibroosseous changes in the basal region of the cochlea, extending to the translocation point and/or throughout the electrode track in 42%. Lower SGN counts were more pronounced in translocated cases compared to controls, with a significant difference for segment II (p = 0.019). Although final postoperative hearing outcomes were similar between groups, translocated cases had slower rate of improvement in WRS (p = 0.021). CONCLUSIONS Cochlear implant electrode translocation was associated with greater fibroosseous formation and lower SGN population. Our findings suggest that scalar translocations may slow the rate of improvement in WRS overtime as compared to atraumatic electrode insertions.Level of evidence: IV.
Collapse
|
45
|
Dutrieux N, Quatre R, Péan V, Schmerber S. Correlation Between Cochlear Length, Insertion Angle, and Tonotopic Mismatch for MED-EL FLEX28 Electrode Arrays. Otol Neurotol 2022; 43:48-55. [PMID: 34538852 DOI: 10.1097/mao.0000000000003337] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To investigate the relationship between cochlear length, insertion angle, and tonotopic mismatch and to compare the tonotopic mismatches with respect to the spiral ganglion and the organ of Corti. STUDY DESIGN Retrospective. SETTING Tertiary referral center with cochlear implant program. PATIENTS Analyses of patients' computed tomography images after cochlear implant surgery. INTERVENTION Cochlear implantation with 28-mm-long straight lateral wall electrode arrays. MAIN OUTCOME MEASURE Cochlear length, insertion angle, and insertion depth were assessed using the OTOPLAN software. Tonotopic mismatch for each electrode contact was estimated using the Greenwood (organ of Corti) and the Stakhovskaya (spiral ganglion) maps and compared. RESULTS 106 cochleae were analyzed. 99% of the electrode arrays were located in the tympanic ramp. The insertion was complete in 96% of cases. The mean cochlear length was 34.5 mm and the mean insertion angle of the apical electrode was 545°. Cochlear length was negatively correlated with the insertion angle of the contacts E1 to E9 (all p < 0.004). The tonotopic mismatch was greater at the organ of Corti than at the spiral ganglion. It was also greater at the organ of Corti in larger cochleae (correlation with mismatch for E1 r = 0.421, p < 0.0001) and in the apical than in the middle and basal regions of the cochlea. CONCLUSION Small cochlea size corresponded to higher insertion angle and reduction of tonotopic mismatch on a 28-mm-long straight lateral wall electrode array. Tonotopic mismatch could be minimized preoperatively by choosing electrode arrays according to the individual cochlear morphology and postoperatively by appropriate frequency fitting.
Collapse
Affiliation(s)
- Noémie Dutrieux
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Grenoble Alpes University Hospital, France
- Medical Faculty, University of Grenoble Alpes, Grenoble, France
| | - Raphaële Quatre
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Grenoble Alpes University Hospital, France
- Medical Faculty, University of Grenoble Alpes, Grenoble, France
| | | | - Sébastien Schmerber
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Grenoble Alpes University Hospital, France
- Medical Faculty, University of Grenoble Alpes, Grenoble, France
- Brain Tech Inserm Laboratory, UMR 1205, University of Grenoble Alpes, Grenoble, France
| |
Collapse
|
46
|
Walia A, Shew MA, Lefler SM, Kallogjeri D, Wick CC, Holden TA, Durakovic N, Ortmann AJ, Herzog JA, Buchman CA. Is Characteristic Frequency Limiting Real-Time Electrocochleography During Cochlear Implantation? Front Neurosci 2022; 16:915302. [PMID: 35937872 PMCID: PMC9354607 DOI: 10.3389/fnins.2022.915302] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 06/15/2022] [Indexed: 12/05/2022] Open
Abstract
Objectives Electrocochleography (ECochG) recordings during cochlear implantation have shown promise in estimating the impact on residual hearing. The purpose of the study was (1) to determine whether a 250-Hz stimulus is superior to 500-Hz in detecting residual hearing decrement and if so; (2) to evaluate whether crossing the 500-Hz tonotopic, characteristic frequency (CF) place partly explains the problems experienced using 500-Hz. Design Multifrequency ECochG comprising an alternating, interleaved acoustic complex of 250- and 500-Hz stimuli was used to elicit cochlear microphonics (CMs) during insertion. The largest ECochG drops (≥30% reduction in CM) were identified. After insertion, ECochG responses were measured using the individual electrodes along the array for both 250- and 500-Hz stimuli. Univariate regression was used to predict whether 250- or 500-Hz CM drops explained low-frequency pure tone average (LFPTA; 125-, 250-, and 500-Hz) shift at 1-month post-activation. Postoperative CT scans were performed to evaluate cochlear size and angular insertion depth. Results For perimodiolar insertions (N = 34), there was a stronger linear correlation between the largest ECochG drop using 250-Hz stimulus and LFPTA shift (r = 0.58), compared to 500-Hz (r = 0.31). The 250- and 500-Hz CM insertion tracings showed an amplitude peak at two different locations, with the 500-Hz peak occurring earlier in most cases than the 250-Hz peak, consistent with tonotopicity. When using the entire array for recordings after insertion, a maximum 500-Hz response was observed 2-6 electrodes basal to the most-apical electrode in 20 cases (58.9%). For insertions where the apical insertion angle is >350 degrees and the cochlear diameter is <9.5 mm, the maximum 500-Hz ECochG response may occur at the non-apical most electrode. For lateral wall insertions (N = 14), the maximum 250- and 500-Hz CM response occurred at the most-apical electrode in all but one case. Conclusion Using 250-Hz stimulus for ECochG feedback during implantation is more predictive of hearing preservation than 500-Hz. This is due to the electrode passing the 500-Hz CF during insertion which may be misidentified as intracochlear trauma; this is particularly important in subjects with smaller cochlear diameters and deeper insertions. Multifrequency ECochG can be used to differentiate between trauma and advancement of the apical electrode beyond the CF.
Collapse
|
47
|
Lenarz T, Buechner A, Gantz B, Hansen M, Tejani VD, Labadie R, O'Connell B, Buchman CA, Valenzuela CV, Adunka OF, Harris MS, Riggs WJ, Fitzpatrick D, Koka K. Relationship Between Intraoperative Electrocochleography and Hearing Preservation. Otol Neurotol 2022; 43:e72-e78. [PMID: 34739427 PMCID: PMC8671360 DOI: 10.1097/mao.0000000000003403] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
OBJECTIVES To compare intraoperative intracochlear electrocochleography (ECochG) with hearing preservation outcomes in cochlear implant (CI) subjects. DESIGN Intraoperative electrocochleography was performed in adult CI subjects who were recipients of Advanced Bionics' Bionics LLC precurved HiFocus MidScala or straight HiFocus SlimJ electrode arrays. ECochG responses were recorded from the most apical electrode contact during insertion. No changes to the insertions were made due to ECochG monitoring. No information about insertion resistance was collected. ECochG drops were estimated as the change in amplitude from peak (defined as maximum amplitude response) to drop (largest drop) point after the peak during insertion was measured following the peak response. Audiometric thresholds from each subject were obtained before and approximately 1 month after CI surgery. The change in pure tone average for frequencies between 125 Hz and 500 Hz was measured after surgery. No postoperative CT scans were collected as part of this study. RESULTS A total of 68 subjects from five surgical centers participated in the study. The study sample included 30 MidScala and 38 SlimJ electrodes implanted by approximately 20 surgeons who contributed to the study. Although a wide range of results were observed, there was a moderate positive correlation (Pearson Correlation coefficient, r = 0.56, p < 0.01) between the size of the ECochG drop and the magnitude of pure tone average change. This trend was present for both the MidScala and SlimJ arrays. The SlimJ and MidScala arrays produced significantly different hearing loss after surgery. CONCLUSION Large ECochG amplitude drops observed during electrode insertion indicated poorer hearing preservation. Although the outcomes were variable, this information may be helpful to guide surgical decision-making when contemplating full electrode insertion and the likelihood of hearing preservation.
Collapse
Affiliation(s)
- Thomas Lenarz
- Hannover Medical School, Department of Otolaryngology, Hannover, Germany
| | - Andreas Buechner
- Hannover Medical School, Department of Otolaryngology, Hannover, Germany
| | - Bruce Gantz
- University of Iowa, Department of Otolaryngology, Iowa City, Iowa
| | - Marlan Hansen
- University of Iowa, Department of Otolaryngology, Iowa City, Iowa
| | - Viral D Tejani
- University of Iowa, Department of Otolaryngology, Iowa City, Iowa
| | - Robert Labadie
- Vanderbilt University and Medical Center, Department of Otolaryngology, Nashville, Tennessee
| | - Brendan O'Connell
- Charlotte Eye Ear Nose and Throat Associates, P.A., Charlotte, North Carolina
| | - Craig Alan Buchman
- Washington University School of Medicine, Department of Otolaryngology - Head and Neck Surgery, St. Louis, Missouri
| | - Carla V Valenzuela
- Washington University School of Medicine, Department of Otolaryngology - Head and Neck Surgery, St. Louis, Missouri
| | - Oliver F Adunka
- The Ohio State University, Department of Otolaryngology, Columbus, Ohio
| | | | - William J Riggs
- The Ohio State University, Department of Otolaryngology, Columbus, Ohio
| | - Douglas Fitzpatrick
- University of North Carolina at Chapel Hill, Department of Otolaryngology, Chapel Hill, North Carolina
| | - Kanthaiah Koka
- Advanced Bionics LLC, Research and Technology, Valencia, California, USA
| |
Collapse
|
48
|
Mueller F, Hermann J, Weber S, O'Toole Bom Braga G, Topsakal V. Image-Based Planning of Minimally Traumatic Inner Ear Access for Robotic Cochlear Implantation. Front Surg 2021; 8:761217. [PMID: 34901143 PMCID: PMC8655094 DOI: 10.3389/fsurg.2021.761217] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 11/02/2021] [Indexed: 12/12/2022] Open
Abstract
Objective: During robotic cochlear implantation, an image-guided robotic system provides keyhole access to the scala tympani of the cochlea to allow insertion of the cochlear implant array. To standardize minimally traumatic robotic access to the cochlea, additional hard and soft constraints for inner ear access were proposed during trajectory planning. This extension of the planning strategy aims to provide a trajectory that preserves the anatomical and functional integrity of critical intra-cochlear structures during robotic execution and allows implantation with minimal insertion angles and risk of scala deviation. Methods: The OpenEar dataset consists of a library with eight three-dimensional models of the human temporal bone based on computed tomography and micro-slicing. Soft constraints for inner ear access planning were introduced that aim to minimize the angle of cochlear approach, minimize the risk of scala deviation and maximize the distance to critical intra-cochlear structures such as the osseous spiral lamina. For all cases, a solution space of Pareto-optimal trajectories to the round window was generated. The trajectories satisfy the hard constraints, specifically the anatomical safety margins, and optimize the aforementioned soft constraints. With user-defined priorities, a trajectory was parameterized and analyzed in a virtual surgical procedure. Results: In seven out of eight cases, a solution space was found with the trajectories safely passing through the facial recess. The solution space was Pareto-optimal with respect to the soft constraints of the inner ear access. In one case, the facial recess was too narrow to plan a trajectory that would pass the nerves at a sufficient distance with the intended drill diameter. With the soft constraints introduced, the optimal target region was determined to be in the antero-inferior region of the round window membrane. Conclusion: A trend could be identified that a position between the antero-inferior border and the center of the round window membrane appears to be a favorable target position for cochlear tunnel-based access through the facial recess. The planning concept presented and the results obtained therewith have implications for planning strategies for robotic surgical procedures to the inner ear that aim for minimally traumatic cochlear access and electrode array implantation.
Collapse
Affiliation(s)
- Fabian Mueller
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Jan Hermann
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Stefan Weber
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | | | - Vedat Topsakal
- Department of Otorhinolaryngology, Head and Neck Surgery, Vrije Universiteit Brussel, Brussels, Belgium.,Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| |
Collapse
|
49
|
Fan Y, Zhang D, Banalagay R, Wang J, Noble JH, Dawant BM. Hybrid active shape and deep learning method for the accurate and robust segmentation of the intracochlear anatomy in clinical head CT and CBCT images. J Med Imaging (Bellingham) 2021; 8:064002. [PMID: 34853805 DOI: 10.1117/1.jmi.8.6.064002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 11/08/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: Robust and accurate segmentation methods for the intracochlear anatomy (ICA) are a critical step in the image-guided cochlear implant programming process. We have proposed an active shape model (ASM)-based method and a deep learning (DL)-based method for this task, and we have observed that the DL method tends to be more accurate than the ASM method while the ASM method tends to be more robust. Approach: We propose a DL-based U-Net-like architecture that incorporates ASM segmentation into the network. A quantitative analysis is performed on a dataset that consists of 11 cochlea specimens for which a segmentation ground truth is available. To qualitatively evaluate the robustness of the method, an experienced expert is asked to visually inspect and grade the segmentation results on a clinical dataset made of 138 image volumes acquired with conventional CT scanners and of 39 image volumes acquired with cone beam CT (CBCT) scanners. Finally, we compare training the network (1) first with the ASM results, and then fine-tuning it with the ground truth segmentation and (2) directly with the specimens with ground truth segmentation. Results: Quantitative and qualitative results show that the proposed method increases substantially the robustness of the DL method while having only a minor detrimental effect (though not significant) on its accuracy. Expert evaluation of the clinical dataset shows that by incorporating the ASM segmentation into the DL network, the proportion of good segmentation cases increases from 60/177 to 119/177 when training only with the specimens and increases from 129/177 to 151/177 when pretraining with the ASM results. Conclusions: A hybrid ASM and DL-based segmentation method is proposed to segment the ICA in CT and CBCT images. Our results show that combining DL and ASM methods leads to a solution that is both robust and accurate.
Collapse
Affiliation(s)
- Yubo Fan
- Vanderbilt University, Department of Computer Science, Nashville, Tennessee, United States
| | | | - Rueben Banalagay
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Jianing Wang
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Jack H Noble
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Benoit M Dawant
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| |
Collapse
|
50
|
Dong Y, Briaire JJ, Siebrecht M, Stronks HC, Frijns JHM. Detection of Translocation of Cochlear Implant Electrode Arrays by Intracochlear Impedance Measurements. Ear Hear 2021; 42:1397-1404. [PMID: 33974777 PMCID: PMC8378542 DOI: 10.1097/aud.0000000000001033] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Misplacement of the electrode array is associated with impaired speech perception in patients with cochlear implants (CIs). Translocation of the electrode array is the most common misplacement. When a CI is translocated, it crosses the basilar membrane from the scala tympani into the scala vestibuli. The position of the implant can be determined on a postoperative CT scan. However, such a scan is not obtained routinely after CI insertion in many hospitals, due to radiation exposure and processing time. Previous studies have shown that impedance measures might provide information on the placement of the electrode arrays. The electrode impedance was measured by dividing the plateau voltage at the end of the first phase of the pulse by the injected current. The access resistance was calculated using the so-called access voltage at the first sampled time point after the start of the pulse divided by the injected current. In our study, we obtained the electrode impedance and the access resistance to detect electrode translocations using electrical field imaging. We have investigated how reliably these two measurements can detect electrode translocation, and which method performed best. DESIGN We calculated the electrode impedances and access resistances using electrical field imaging recordings from 100 HiFocus Mid-Scala CI (Advanced Bionics, Sylmar, CA) recipients. We estimated the normal values of these two measurements as the baselines of the implant placed in the cochlea without translocation. Next, we calculated the maximal electrode impedance deviation and the maximal access-resistance deviation from the respective baselines as predictors of translocation. We classified these two predictors as translocations or nontranslocations based on the bootstrap sampling method and receiver operating characteristics curves analysis. The accuracy could be calculated by comparing those predictive results to a gold standard, namely the clinical CT scans. To determine which measurement more accurately detected translocation, the difference between the accuracies of the two measurements was calculated. RESULTS Using the bootstrap sampling method and receiver operating characteristics-based optimized threshold criteria, the 95% confidence intervals of the accuracies of translocation detections ranged from 77.8% to 82.1% and from 89.5% to 91.2% for the electrode impedance and access resistance, respectively. The accuracies of the maximal access-resistance deviations were significantly larger than that of the maximal electrode impedance deviations. The location of the translocation as predicted by the access resistance was significantly correlated with the result derived from the CT scans. In contrast, no significant correlation was observed for the electrode impedance. CONCLUSIONS Both the electrode impedance and access resistance proved reliable metrics to detect translocations for HiFocus Mid-Scala electrode arrays. The access resistance had, however, significantly better accuracy and it also reliably detected the electrode-location of translocations. The electrode impedance did not correlate significantly with the location of translocation. Measuring the access resistance is, therefore, the recommended method to detect electrode-array translocations. These measures can provide prompt feedback for surgeons after insertion, improving their surgical skills, and ultimately reducing the number of translocations. In the future, such measurements may allow near-real-time monitoring of the electrode array during insertion, helping to avoid translocations.
Collapse
Affiliation(s)
- Yu Dong
- ENT-Department, Leiden University Medical Centre, RC Leiden, the Netherlands
| | - Jeroen J. Briaire
- ENT-Department, Leiden University Medical Centre, RC Leiden, the Netherlands
| | - Michael Siebrecht
- ENT-Department, Leiden University Medical Centre, RC Leiden, the Netherlands
| | | | - Johan H. M. Frijns
- ENT-Department, Leiden University Medical Centre, RC Leiden, the Netherlands
- Leiden Institute for Brain and Cognition, RC Leiden, the Netherlands
| |
Collapse
|