1
|
Katz I, Tissier R, Kohlhauer M, Lemaire J, Hamlin A, Chalopin M, Farjot G, Milet A. Argon pharmacokinetics: measurements in pigs and analysis in humans using a physiologically based pharmacokinetics model. Med Gas Res 2024; 14:206-212. [PMID: 39073329 DOI: 10.4103/mgr.mgr_20_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Accepted: 01/22/2024] [Indexed: 07/30/2024] Open
Abstract
The primary objective of this study was to investigate the pharmacokinetics of inhaled argon in young pigs using mechanical ventilation. Also a physiologically based model of argon pharmacokinetics (PBPK) is validated with human data for xenon from the literature and the new data from juvenile pigs. The inherent difficulty in performing pharmacokinetics studies of argon makes the use of the PBPK model especially relevant. The model is used to investigate argon pharmacokinetics for adult and neonate applications. Juvenile pigs (n = 4) were anesthetized, submitted to endotracheal intubation, and mechanical ventilation using a conventional ventilator. Argon inhalation was achieved by switching the animal from the first mechanical ventilator (with air/oxygen) to a second one that was supplied with 75% argon and 25% oxygen from premixed gas cylinders. This administration yielded blood samples that were analyzed using a quadrupole based technique for determining argon concentration. The range of blood:gas partition coefficient corresponding to the average measured Cmax of 190-872 μM is 0.005-0.022. Based on the average curve, T1/2= 75 seconds. The PBPK is shown to be in general agreement with the experimental data in pigs. Inhaled argon administration exhibited an on-off nature such that AUC was proportional to administration time. Confidence in the PBPK model and the remarkably robust and stable on-off nature of argon pharmacokinetics, notwithstanding intersubject variability and comorbidity, suggests that inhaled argon could readily be applied to any treatment regime.
Collapse
Affiliation(s)
- Ira Katz
- Early Drug Development, Air Liquide Santé International, Les loges-en-Josas, France
| | - Renaud Tissier
- Univ Paris Est Créteil, Institut National de la Santé et de la Recherche Médicale, Mondor Institute for Biomedical Research, Créteil, France
- Ecole Nationale Vétérinaire d'Alfort, Mondor Institute for Biomedical Research, Maisons-Alfort, France
| | - Matthias Kohlhauer
- Univ Paris Est Créteil, Institut National de la Santé et de la Recherche Médicale, Mondor Institute for Biomedical Research, Créteil, France
- Ecole Nationale Vétérinaire d'Alfort, Mondor Institute for Biomedical Research, Maisons-Alfort, France
| | - Joël Lemaire
- Institut de Chimie Physique, Centre National de la Recherche Scientifique, Université Paris-Saclay, Orsay, France
| | - Arthur Hamlin
- Institut de Chimie Physique, Centre National de la Recherche Scientifique, Université Paris-Saclay, Orsay, France
| | - Matthieu Chalopin
- Early Drug Development, Air Liquide Santé International, Les loges-en-Josas, France
| | - Géraldine Farjot
- Early Drug Development, Air Liquide Santé International, Les loges-en-Josas, France
| | - Aude Milet
- Early Drug Development, Air Liquide Santé International, Les loges-en-Josas, France
| |
Collapse
|
2
|
Wen Y, Xie Y, Wang C, Hua L, Zhang L, Chen P, Li H. Determination of the two-compartment model parameters of exhaled HCN by fast negative photoionization mass spectrometry. Talanta 2024; 271:125710. [PMID: 38295448 DOI: 10.1016/j.talanta.2024.125710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Revised: 01/18/2024] [Accepted: 01/22/2024] [Indexed: 02/02/2024]
Abstract
Breath exhaled hydrogen cyanide (HCN) has been identified to be associated with several respiratory diseases. Accurately distinguishing the concentration and release rate of different HCN sources is of great value in clinical research. However, there are still significant challenges due to the high adsorption and low concentration characteristics of exhaled HCN. In this study, a two-compartment kinetic model method based on negative photoionization mass spectrometry was developed to simultaneously determine the kinetic parameters including concentrations and release rates in the airways and alveoli. The influences of the sampling line diameter, length, and temperature on the response time of the sampling system were studied and optimized, achieving a response time of 0.2 s. The negative influence of oral cavity-released HCN was reduced by employing a strategy based on anatomical lung volume calculation. The calibration for HCN in the dynamic range of 0.5-100 ppbv and limit of detection (LOD) at 0.3 ppbv were achieved. Subsequently, the experiments of smoking, short-term passive smoking, and intake of bitter almonds were performed to examine the influences of endogenous and exogenous factors on the dynamic parameters of the model method. The results indicate that compared with steady-state concentration measurements, the kinetic parameters obtained using this model method can accurately and significantly reflect the changes in different HCN sources, highlighting its potential for HCN-related disease research.
Collapse
Affiliation(s)
- Yuxuan Wen
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing, 100049, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China; Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian, 116023, People's Republic of China
| | - Yuanyuan Xie
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China; Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian, 116023, People's Republic of China
| | - Chen Wang
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing, 100049, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China; Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian, 116023, People's Republic of China
| | - Lei Hua
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China; Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian, 116023, People's Republic of China
| | - Lichuan Zhang
- Affiliated Zhongshan Hospital of Dalian University, Dalian, People's Republic of China
| | - Ping Chen
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China; Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian, 116023, People's Republic of China.
| | - Haiyang Li
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China; Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian, 116023, People's Republic of China.
| |
Collapse
|
3
|
Tolerance of Human Fibroblasts to Benfo-Oxythiamine In Vitro. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19074112. [PMID: 35409800 PMCID: PMC8998213 DOI: 10.3390/ijerph19074112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 03/17/2022] [Accepted: 03/25/2022] [Indexed: 11/17/2022]
Abstract
OBJECTIVES To explore the potential application of B-OT in the aspiration tract. MATERIALS AND METHODS We conceived and optimized an in vitro model simulating the mouth-washing process to assess tolerance to B-OT on primary human gingival fibroblasts. Cells derived from 4 unrelated donors were flushed with medium containing drugs of various concentration for one minute twice daily for 3 days. RESULTS No effect was seen on the cells up to 1000 µM B-OT. In addition, we treated the cells with B-OT permanently in medium, corresponding to a systemic treatment. No effect was seen by 10 µM B-OT and only a slight reduction (approximately 10%) was seen by 100 µM B-OT. CONCLUSIONS Our results suggest good tolerance of oral cells for B-OT, favoring the further development of this antiviral reagent as a mouth-washing solution and nasal spray.
Collapse
|
4
|
A Low-Cost Breath Analyzer Module in Domiciliary Non-Invasive Mechanical Ventilation for Remote COPD Patient Monitoring. SENSORS 2020; 20:s20030653. [PMID: 31991608 PMCID: PMC7038329 DOI: 10.3390/s20030653] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 01/14/2020] [Accepted: 01/17/2020] [Indexed: 02/07/2023]
Abstract
Smart Breath Analyzers were developed as sensing terminals of a telemedicine architecture devoted to remote monitoring of patients suffering from Chronic Obstructive Pulmonary Disease (COPD) and home-assisted by non-invasive mechanical ventilation via respiratory face mask. The devices based on different sensors (CO2/O2 and Volatile Organic Compounds (VOCs), relative humidity and temperature (R.H. & T) sensors) monitor the breath air exhaled into the expiratory line of the bi-tube patient breathing circuit during a noninvasive ventilo-therapy session; the sensor raw signals are transmitted pseudonymized to National Health Service units by TCP/IP communication through a cloud remote platform. The work is a proof-of-concept of a sensors-based IoT system with the perspective to check continuously the effectiveness of therapy and/or any state of exacerbation of the disease requiring healthcare. Lab tests in controlled experimental conditions by a gas-mixing bench towards CO2/O2 concentrations and exhaled breath collected in a sampling bag were carried out to test the realized prototypes. The Smart Breath Analyzers were also tested in real conditions both on a healthy volunteer subject and a COPD suffering patient.
Collapse
|
5
|
Ghorbani R, Schmidt FM. Fitting of single-exhalation profiles using a pulmonary gas exchange model—application to carbon monoxide. J Breath Res 2019; 13:026001. [DOI: 10.1088/1752-7163/aafc91] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
6
|
Ghorbani R, Blomberg A, Schmidt FM. Modeling Pulmonary Gas Exchange and Single-Exhalation Profiles of Carbon Monoxide. Front Physiol 2018; 9:927. [PMID: 30104980 PMCID: PMC6077244 DOI: 10.3389/fphys.2018.00927] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Accepted: 06/25/2018] [Indexed: 12/20/2022] Open
Abstract
Exhaled breath carbon monoxide (eCO) is a candidate biomarker for non-invasive assessment of oxidative stress and respiratory diseases. Standard end-tidal CO analysis, however, cannot distinguish, whether eCO reflects endogenous CO production, lung diffusion properties or exogenous sources, and is unable to resolve a potential airway contribution. Coupling real-time breath gas analysis to pulmonary gas exchange modeling holds promise to improve the diagnostic value of eCO. A trumpet model with axial diffusion (TMAD) is used to simulate the dynamics of CO gas exchange in the respiratory system and corresponding eCO concentrations for the first time. The mass balance equation is numerically solved employing a computationally inexpensive routine implementing the method of lines, which provides the distribution of CO in the respiratory tract during inhalation, breath-holding, and exhalation with 1 mm spatial and 0.01 s temporal resolution. Initial estimates of the main TMAD parameters, the maximum CO fluxes and diffusing capacities in alveoli and airways, are obtained using healthy population tissue, blood and anatomical data. To verify the model, mouth-exhaled expirograms from two healthy subjects, measured with a novel, home-built laser-based CO sensor, are compared to single-exhalation profiles simulated using actual breath sampling data, such as exhalation flow rate (EFR) and volume. A very good agreement is obtained in exhalation phases I and III for EFRs between 55 and 220 ml/s and after 10 and 20 s of breath-holding, yielding a unique set of TMAD parameters. The results confirm the recently observed EFR dependence of CO expirograms and suggest that measured end-tidal eCO is always lower than alveolar and capillary CO. Breath-holding allows the observation of close-to-alveolar CO concentrations and increases the sensitivity to the airway TMAD parameters in exhalation phase I. A parametric simulation study shows that a small increase in airway flux can be distinguished from an increase in alveolar flux, and that slight changes in alveolar flux and diffusing capacity have a significantly different effect on phase III of the eCO profiles.
Collapse
Affiliation(s)
- Ramin Ghorbani
- Department of Applied Physics and Electronics, Umeå University, Umeå, Sweden
| | - Anders Blomberg
- Division of Medicine, Department of Public Health and Clinical Medicine, Umeå University, Umeå, Sweden
| | - Florian M Schmidt
- Department of Applied Physics and Electronics, Umeå University, Umeå, Sweden
| |
Collapse
|
7
|
Wei W, Bonvallot N, Gustafsson Å, Raffy G, Glorennec P, Krais A, Ramalho O, Le Bot B, Mandin C. Bioaccessibility and bioavailability of environmental semi-volatile organic compounds via inhalation: A review of methods and models. ENVIRONMENT INTERNATIONAL 2018; 113:202-213. [PMID: 29448239 DOI: 10.1016/j.envint.2018.01.024] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 01/22/2018] [Accepted: 01/23/2018] [Indexed: 05/06/2023]
Abstract
Semi-volatile organic compounds (SVOCs) present in indoor environments are known to cause adverse health effects through multiple routes of exposure. To assess the aggregate exposure, the bioaccessibility and bioavailability of SVOCs need to be determined. In this review, we discussed measurements of the bioaccessibility and bioavailability of SVOCs after inhalation. Published literature related to this issue is available for 2,3,7,8-tetrachlorodibenzo-p-dioxin and a few polycyclic aromatic hydrocarbons, such as benzo[a]pyrene and phenanthrene. Then, we reviewed common modeling approaches for the characterization of the gas- and particle-phase partitioning of SVOCs during inhalation. The models are based on mass transfer mechanisms as well as the structure of the respiratory system, using common computational techniques, such as computational fluid dynamics. However, the existing models are restricted to special conditions and cannot predict SVOC bioaccessibility and bioavailability in the whole respiratory system. The present review notes two main challenges for the estimation of SVOC bioaccessibility and bioavailability via inhalation in humans. First, in vitro and in vivo methods need to be developed and validated for a wide range of SVOCs. The in vitro methods should be validated with in vivo tests to evaluate human exposures to SVOCs in airborne particles. Second, modeling approaches for SVOCs need to consider the whole respiratory system. Alterations of the respiratory cycle period and human biological variability may be considered in future studies.
Collapse
Affiliation(s)
- Wenjuan Wei
- University of Paris-Est, Scientific and Technical Center for Building (CSTB), Health and Comfort Department, French Indoor Air Quality Observatory (OQAI), 84 Avenue Jean Jaurès, Champs sur Marne, 77447 Marne la Vallée Cedex 2, France.
| | - Nathalie Bonvallot
- EHESP-School of Public Health, Sorbonne Paris Cité, Rennes, France; INSERM-UMR 1085, Irset-Research Institute for Environmental and Occupational Health, Rennes, France
| | - Åsa Gustafsson
- Swetox, Karolinska Institute, Unit of Toxicology Sciences, Forskargatan 20, SE-151 36 Södertälje, Sweden; Department of Chemistry, Umeå University, Linnaeus väg 6, SE-901 87 Umeå, Sweden
| | - Gaëlle Raffy
- EHESP-School of Public Health, Sorbonne Paris Cité, Rennes, France; INSERM-UMR 1085, Irset-Research Institute for Environmental and Occupational Health, Rennes, France; LERES-Environment and Health Research Laboratory (Irset and EHESP Technologic Platform), Rennes, France
| | - Philippe Glorennec
- EHESP-School of Public Health, Sorbonne Paris Cité, Rennes, France; INSERM-UMR 1085, Irset-Research Institute for Environmental and Occupational Health, Rennes, France
| | - Annette Krais
- Swetox, Karolinska Institute, Unit of Toxicology Sciences, Forskargatan 20, SE-151 36 Södertälje, Sweden; Department of Occupational and Environmental Medicine, Department of Laboratory Medicine, Lund University, SE-221 85, Lund, Sweden
| | - Olivier Ramalho
- University of Paris-Est, Scientific and Technical Center for Building (CSTB), Health and Comfort Department, French Indoor Air Quality Observatory (OQAI), 84 Avenue Jean Jaurès, Champs sur Marne, 77447 Marne la Vallée Cedex 2, France
| | - Barbara Le Bot
- EHESP-School of Public Health, Sorbonne Paris Cité, Rennes, France; INSERM-UMR 1085, Irset-Research Institute for Environmental and Occupational Health, Rennes, France; LERES-Environment and Health Research Laboratory (Irset and EHESP Technologic Platform), Rennes, France
| | - Corinne Mandin
- University of Paris-Est, Scientific and Technical Center for Building (CSTB), Health and Comfort Department, French Indoor Air Quality Observatory (OQAI), 84 Avenue Jean Jaurès, Champs sur Marne, 77447 Marne la Vallée Cedex 2, France
| |
Collapse
|