1
|
Pearce DP, Witzenburg CM. Evaluation of an Inverse Method for Quantifying Spatially Variable Mechanics. J Biomech Eng 2024; 146:121006. [PMID: 39240274 DOI: 10.1115/1.4066434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Accepted: 08/14/2024] [Indexed: 09/07/2024]
Abstract
Soft biological tissues often function as highly deformable membranes in vivo and exhibit impressive mechanical behavior effectively characterized by planar biaxial testing. The Generalized Anisotropic Inverse Mechanics (GAIM) method links full-field deformations and boundary forces from mechanical testing to quantify material properties of soft, anisotropic, heterogeneous tissues. In this study, we introduced an orthotropic constraint to GAIM to improve the quality and physical significance of its mechanical characterizations. We evaluated the updated GAIM method using simulated and experimental biaxial testing datasets obtained from soft tissue analogs (PDMS and TissueMend) with well-defined mechanical properties. GAIM produced stiffnesses (first Kelvin moduli, K1) that agreed well with previously published Young's moduli of PDMS samples. It also matched the stiffness moduli determined via uniaxial testing for TissueMend, a collagen-rich patch intended for tendon repair. We then conducted the first biaxial testing of TissueMend and confirmed that the sample was mechanically anisotropic via a relative anisotropy metric produced by GAIM. Next, we demonstrated the benefits of full-field laser micrometry in distinguishing between spatial variations in thickness and stiffness. Finally, we conducted an analysis to verify that results were independent of partitioning scheme. The success of the newly implemented constraints on GAIM suggests notable potential for applying this tool to soft tissues, particularly following the onset of pathologies that induce mechanical and structural heterogeneities.
Collapse
Affiliation(s)
- Daniel P Pearce
- Department of Biomedical Engineering, University of Wisconsin-Madison, 1550 Engineering Drive, ECB 2139, Madison, WI 53706
| | - Colleen M Witzenburg
- Department of Biomedical Engineering, University of Wisconsin-Madison, 1550 Engineering Drive, ECB 2139, Madison, WI 53706
| |
Collapse
|
2
|
Yun J, Cho M, Culver M, Pearce DP, Kim C, Witzenburg CM, Murphy WL, Gopalan P. Characterization of Decellularized Plant Leaf as an Emerging Biomaterial Platform. ACS Biomater Sci Eng 2024; 10:6144-6154. [PMID: 39214606 DOI: 10.1021/acsbiomaterials.4c01254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
Decellularized plants have emerged as promising biomaterials for cell culture and tissue engineering applications due to their distinct material characteristics. This study explores the biochemical, mechanical, and structural properties of decellularized leaves that make them useful as biomaterials for cell culture. Five monocot leaf species were decellularized via alkali treatment, resulting in the effective removal of DNA and proteins. The Van Soest method was used to quantitatively evaluate the changes in cellulose, hemicellulose, and lignin content during decellularization. Tensile tests revealed considerable variations in mechanical strength depending on the plant species, the decellularization state, and the direction of applied mechanical force. Decellularized monocot leaves exhibited a notable reduction in mechanical strength and anisotropic properties depending on the leaf orientation. Imaging revealed inherent microgrooves on the epidermis of the monocot leaves. Permeability studies, including water uptake and biomolecule transport through decellularized leaves, confirmed excellent water uptake capability but limited biomolecule transport. Lastly, the plants were enzymatically degradable using typical plant enzymes, which were minimally cytotoxic to mammalian cells. Taken together, the features of decellularized plant leaves characterized in this study suggest ways in which they can be useful in cell culture and tissue engineering applications.
Collapse
Affiliation(s)
- Junsu Yun
- Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
| | - Mina Cho
- Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
| | - Matthew Culver
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53075, United States
| | - Daniel P Pearce
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53075, United States
| | - Chanul Kim
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53075, United States
| | - Colleen M Witzenburg
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53075, United States
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53075, United States
| | - William L Murphy
- Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53075, United States
- Department of Orthopedics and Rehabilitation, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705, United States
| | - Padma Gopalan
- Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53075, United States
| |
Collapse
|
3
|
Nelson TM, Mariano CA, Ramirez GO, Badrou A, Quiros KAM, Shankel M, Eskandari M. Lung Mechanics: Material Characterization of Pulmonary Constituents for an Experimentally Informed Computational Pipeline. Curr Protoc 2024; 4:e70001. [PMID: 39240156 DOI: 10.1002/cpz1.70001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2024]
Abstract
The lung comprises multiple components including the parenchyma, airways, and visceral pleura, where each constituent displays specific material properties that together govern the whole organ's properties. The structural and mechanical complexity of the lung has historically undermined its comprehensive characterization, especially compared to other biological organs, such as the heart or bones. This knowledge void is particularly remarkable when considering that pulmonary disease is one of the leading causes of morbidity and mortality across the globe. Establishing the mechanical properties of the lung is central to formulating a baseline understanding of its operation, which can facilitate investigations of diseased states and how the lung will potentially respond to clinical interventions. Here, we present established and widely accepted experimental protocols for pulmonary material quantification, specifying how to extract, prepare, and test each type of lung constituent under planar biaxial tensile loading to investigate the mechanical properties, such as physiological stress-strain profiles, anisotropy, and viscoelasticity. These methods are presented across an array of commonly studied species (murine, rat, and porcine). Additionally, we highlight how such material properties may inform the construction of an inverse finite element model, which is central to implementing predictive computational tools for accurate disease diagnostics and optimized medical treatments. These presented methodologies are aimed at supporting research advancements in the field of pulmonary biomechanics and to help inaugurate future novel studies. © 2024 The Author(s). Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: General procedures in lung biaxial testing Alternate Protocol 1: Parenchymal-specific preparation and loading procedures Alternate Protocol 2: Airway-specific preparation and loading procedures Alternate Protocol 3: Visceral pleura-specific preparation and loading procedures Basic Protocol 2: Computational analysis.
Collapse
Affiliation(s)
- Talyah M Nelson
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Crystal A Mariano
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Gustavo O Ramirez
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Arif Badrou
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Kathrine A M Quiros
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Matthew Shankel
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Mona Eskandari
- Department of Mechanical Engineering, University of California, Riverside, California
- BREATHE Center, School of Medicine University of California, Riverside, California
- Department of Bioengineering, University of California, Riverside, California
| |
Collapse
|
4
|
Lin CY, Mathur M, Malinowski M, Timek TA, Rausch MK. The impact of thickness heterogeneity on soft tissue biomechanics: a novel measurement technique and a demonstration on heart valve tissue. Biomech Model Mechanobiol 2023; 22:1487-1498. [PMID: 36284075 PMCID: PMC10231866 DOI: 10.1007/s10237-022-01640-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 09/19/2022] [Indexed: 11/27/2022]
Abstract
The mechanical properties of soft tissues are driven by their complex, heterogeneous composition and structure. Interestingly, studies of soft tissue biomechanics often ignore spatial heterogeneity. In our work, we are therefore interested in exploring the impact of tissue heterogeneity on the mechanical properties of soft tissues. Therein, we specifically focus on soft tissue heterogeneity arising from spatially varying thickness. To this end, our first goal is to develop a non-destructive measurement technique that has a high spatial resolution, provides continuous thickness maps, and is fast. Our secondary goal is to demonstrate that including spatial variation in thickness is important to the accuracy of biomechanical analyses. To this end, we use mitral valve leaflet tissue as our model system. To attain our first goal, we identify a soft tissue-specific contrast protocol that enables thickness measurements using a Keyence profilometer. We also show that this protocol does not affect our tissues' mechanical properties. To attain our second goal, we conduct virtual biaxial, bending, and buckling tests on our model tissue both ignoring and considering spatial variation in thickness. Thereby, we show that the assumption of average, homogeneous thickness distributions significantly alters the results of biomechanical analyses when compared to including true, spatially varying thickness distributions. In conclusion, our work provides a novel measurement technique that can capture continuous thickness maps non-invasively, at high resolution, and in a short time. Our work also demonstrates the importance of including heterogeneous thickness in biomechanical analyses of soft tissues.
Collapse
Affiliation(s)
- Chien-Yu Lin
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, 78712, USA
| | - Mrudang Mathur
- Department of Mechanical Engineering, University of Texas at Austin, Austin, TX, 78712, USA
| | - Marcin Malinowski
- Division of Cardiothoracic Surgery, Spectrum Health, Grand Rapids, MI, 49503, USA
- Department of Cardiac Surgery, School of Medicine in Katowice, Medical University of Silesia, Katowice, Poland
| | - Tomasz A Timek
- Division of Cardiothoracic Surgery, Spectrum Health, Grand Rapids, MI, 49503, USA
| | - Manuel K Rausch
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, 78712, USA.
- Department of Aerospace Engineering and Engineering Mechanics, University of Texas at Austin, Austin, TX, 78712, USA.
- Oden Institute for Computational Engineering and Sciences, University of Texas at Austin, Austin, TX, 78712, USA.
| |
Collapse
|
5
|
Pearce DP, Nemcek MT, Witzenburg CM. Don't go breakin' my heart: cardioprotective alterations to the mechanical and structural properties of reperfused myocardium during post-infarction inflammation. Biophys Rev 2023; 15:329-353. [PMID: 37396449 PMCID: PMC10310682 DOI: 10.1007/s12551-023-01068-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Accepted: 05/21/2023] [Indexed: 07/04/2023] Open
Abstract
Myocardial infarctions (MIs) kickstart an intense inflammatory response resulting in extracellular matrix (ECM) degradation, wall thinning, and chamber dilation that leaves the heart susceptible to rupture. Reperfusion therapy is one of the most effective strategies for limiting adverse effects of MIs, but is a challenge to administer in a timely manner. Late reperfusion therapy (LRT; 3 + hours post-MI) does not limit infarct size, but does reduce incidences of post-MI rupture and improves long-term patient outcomes. Foundational studies employing LRT in the mid-twentieth century revealed beneficial reductions in infarct expansion, aneurysm formation, and left ventricle dysfunction. The mechanism by which LRT acts, however, is undefined. Structural analyses, relying largely on one-dimensional estimates of ECM composition, have found few differences in collagen content between LRT and permanently occluded animal models when using homogeneous samples from infarct cores. Uniaxial testing, on the other hand, revealed slight reductions in stiffness early in inflammation, followed soon after by an enhanced resistance to failure for cases of LRT. The use of one-dimensional estimates of ECM organization and gross mechanical function have resulted in a poor understanding of the infarct's spatially variable mechanical and structural anisotropy. To resolve these gaps in literature, future work employing full-field mechanical, structural, and cellular analyses is needed to better define the spatiotemporal post-MI alterations occurring during the inflammatory phase of healing and how they are impacted following reperfusion therapy. In turn, these studies may reveal how LRT affects the likelihood of rupture and inspire novel approaches to guide scar formation.
Collapse
Affiliation(s)
- Daniel P. Pearce
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53706 USA
| | - Mark T. Nemcek
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53706 USA
| | - Colleen M. Witzenburg
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53706 USA
| |
Collapse
|