1
|
Dos S Siqueira JRC, Rodriguez RMM, de C Ramos N, Bottino MA, Tribst JPM. Immediate and Long-Term Pull-Out Bond Strength of 3D-Printed Provisional Crowns. BIOMED RESEARCH INTERNATIONAL 2024; 2024:7205011. [PMID: 39263421 PMCID: PMC11390228 DOI: 10.1155/2024/7205011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 08/09/2024] [Accepted: 08/13/2024] [Indexed: 09/13/2024]
Abstract
Background: Over the past decade, 3D printing technology has revolutionized various fields, including dentistry. Provisional restorations play a crucial role in prosthetic rehabilitation, necessitating the evaluation of their bond strength with different provisional cement agents. Aims: This study is aimed at assessing the immediate and long-term bond strength of 3D-printed dental crowns using three provisional cement agents. Materials and Methods: Provisional crowns (N = 36) were manufactured using 3D modeling software and cemented in dentin analogues (G10 Nema resin). After the crowns' fabrication, they were randomly divided into three groups (n = 12) for cementation with Relyx Temp 3M ESPE, Provicol-VOCO, and Meron-VOCO. Tensile strength tests were conducted using a universal testing machine, with half of the specimens subjected to 2000 thermal cycles before testing. Finite element analysis was employed to assess tensile stress distribution. Results: Statistical analysis (two-way ANOVA and Tukey's test at a 95% confidence level) revealed significant effects of cement type (p = 0.006) and thermal aging (p = 0.001) on bond strength. Glass ionomer cement exhibited the highest immediate resistance, while all types of cement were adversely affected by thermal aging, resulting in decreased bond strength. Conclusion: Thermal aging significantly alters the properties of 3D printing resin and affects the bond strength of provisional cement with 3D-printed crowns. Despite the adverse effects of thermal aging, glass ionomer cement demonstrated the highest immediate resistance. Clinicians should carefully consider these findings when selecting provisional cements for 3D-printed crowns.
Collapse
Affiliation(s)
- Joyce R C Dos S Siqueira
- Department of Dental Materials and Prosthodontics São Paulo State University (UNESP) Institute of Science and Technology, São José dos Campos 12245-000, Brazil
| | - Rita M M Rodriguez
- Department of Dental Materials and Prosthodontics São Paulo State University (UNESP) Institute of Science and Technology, São José dos Campos 12245-000, Brazil
| | - Nathalia de C Ramos
- Department of Dental Materials and Prosthodontics São Paulo State University (UNESP) Institute of Science and Technology, São José dos Campos 12245-000, Brazil
| | - Marco A Bottino
- Department of Dental Materials and Prosthodontics São Paulo State University (UNESP) Institute of Science and Technology, São José dos Campos 12245-000, Brazil
| | - João P M Tribst
- Department of Reconstructive Oral Care Academic Centre for Dentistry Amsterdam (ACTA) 1081 LA, Amsterdam, Netherlands
| |
Collapse
|
2
|
Pilecco RO, Machry RV, Baldi A, Tribst JPM, Sarkis-Onofre R, Valandro LF, Kleverlaan CJ, Scotti N, Pereira GKR. Influence of CAD-CAM milling strategies on the outcome of indirect restorations: A scoping review. J Prosthet Dent 2024; 131:811.e1-811.e10. [PMID: 38480018 DOI: 10.1016/j.prosdent.2024.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 02/19/2024] [Accepted: 02/20/2024] [Indexed: 05/13/2024]
Abstract
STATEMENT OF PROBLEM The influence of computer-aided manufacturing (CAM) parameters and settings on the outcomes of milled indirect restorations is poorly understood. PURPOSE The purpose of this scoping review was to summarize the current CAM systems, parameters, and setting changes, and their effects on different outcomes of milled indirect restorations and aspects related to their manufacture. MATERIAL AND METHODS The protocol of this review is available online (https://osf.io/x28ps/). Studies that used at least 2 different parameters (CAM units, number of axes, digital spacers, or protocols with different rotatory instruments, grit-sizes, milling speed, or others) for milling indirect restorations were included. A structured search up to July 2023 was performed by 2 independent reviewers for articles written in English in LILACS, MEDLINE via PubMed, EMBASE, Web of Science, and Scopus. RESULTS Of 1546 studies identified, 22 were included in the review. Discrepancies were found between the planned and actual measured cement space, with a decreasing linear relationship impacting restoration adaptation at different points. The CEREC MC XL milling machine was the most used system in the included studies, with variations in bur types, milling modes, and number of burs uses affecting internal fit and surface trueness. The results demonstrated the better adaptation of restorations made with 5-axis over 3-axis milling machines. Lithium disilicate and zirconia were the most commonly used materials, and crowns and inlays were popular designs. Marginal and internal adaptation were the primary outcomes assessed using the various techniques. CONCLUSIONS The study presented a comprehensive exploration of CAM systems and parameters, and their influence on indirect restorations. The planned cement space was not properly reproduced by the milling. Bur characteristics can affect restoration fit and trueness. The 5-axis units seem to result in better-adapted restorations compared with 3- and 4-axis units.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- Postgraduate student, Postgraduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Renan Vaz Machry
- Postdoctoral student, Postgraduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Andrea Baldi
- Postdoctoral student, Department of Surgical Sciences, Dental School, Turin, Italy
| | - João Paulo Mendes Tribst
- Assistant Professor, Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, The Netherlands.
| | - Rafael Sarkis-Onofre
- Associate Professor, Graduate Program in Dentistry, Meridional Faculty, IMED, Passo Fundo, Brazil
| | - Luiz Felipe Valandro
- Full Professor, Postgraduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Cornelis Johannes Kleverlaan
- Full Professor, Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, The Netherlands
| | - Nicola Scotti
- Associate Professor, Department of Surgical Sciences, Dental School, Turin, Italy
| | - Gabriel Kalil Rocha Pereira
- Adjunct Professor, Postgraduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| |
Collapse
|
3
|
Capobianco V, Baroudi K, Santos MJMC, Rubo JH, Rizkalla AS, Dal Piva AMDO, Vitti RP, Tribst JPM, Santos GC. Post-fatigue fracture load, stress concentration and mechanical properties of feldspathic, leucite- and lithium disilicate-reinforced glass ceramics. Heliyon 2023; 9:e17787. [PMID: 37449193 PMCID: PMC10336509 DOI: 10.1016/j.heliyon.2023.e17787] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 06/09/2023] [Accepted: 06/28/2023] [Indexed: 07/18/2023] Open
Abstract
Objective To evaluate the mechanical properties of different CAD/CAM ceramic systems and the post-fatigue fracture and stress distribution when used as cemented crowns. Materials and methods Sixty (60) CAD/CAM monolithic crowns were milled using three different ceramic materials (FD - Feldspathic [Vita Mark II]), LE - Leucite-based ceramic [IPS Empress CAD] and LD - Lithium Disilicate [IPS e.max CAD]) and adhesively cemented on resin composite dyes. Specimens were stored in distillated water (37 °C) for 7 days. After, half of the crowns were submitted to immediate fracture load test while the other half was submitted to fatigue cycling. The average cement layer of approximately 80 μm was assessed using scanning electron microscopy (SEM). The average thickness was used in the three-dimensional (3D) Finite Element Analysis (FEA). For each ceramic material, the density, Poisson ratio, shear modulus, Young modulus, fracture toughness, and true hardness were assessed (n = 3). The data was used to assess the Maximum Principal Stress throughout 3D-FEA according to each material during load to fail and post-fatigue. Data were submitted to two-way ANOVA and Tukey test (α = 0.05). Results LD showed the highest compression load, density, shear modulus, Young modulus, fracture toughness and true hardness values. While LE presented the lowest mechanical properties values. There is no difference in the Poisson ratio between the evaluated ceramics. Conclusion LD was susceptible to aging process but presented stronger physicomechanical properties, showing the highest post-fatigue fracture load and highest stress magnitude.
Collapse
Affiliation(s)
| | - Kusai Baroudi
- RAK College of Dental Sciences, RAK Medical & Health Sciences University, RAS Al Khaimah, United Arab Emirates
- School of Dentistry, University of Taubaté, Taubaté, SP, Brazil
| | | | | | - Amin S. Rizkalla
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON, Canada
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials, Academic Centre for Dentistry Amsterdam (ACTA),Universiteit van Amsterdam en Vrije Universiteit, Amsterdam, the Netherlands
| | - Rafael Pino Vitti
- School of Dentistry, Herminio Ometto University Center, Araras, SP, Brazil
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA),Universiteit van Amsterdam en Vrije Universiteit, Amsterdam, the Netherlands
| | - Gildo Coelho Santos
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON, Canada
| |
Collapse
|
4
|
da Rosa LS, Velho HC, Tribst JPM, Valandro LF, Kleverlaan CJ, Pereira GKR. Weak adhesion between ceramic and resin cement impairs the load-bearing capacity under fatigue of lithium disilicate glass-ceramic crowns. J Mech Behav Biomed Mater 2023; 138:105604. [PMID: 36509013 DOI: 10.1016/j.jmbbm.2022.105604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/28/2022] [Accepted: 12/01/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To evaluate the fatigue behavior of lithium disilicate crowns with a simplified anatomy against progressive cement/ceramic debonding scenarios. MATERIALS AND METHODS Lithium disilicate crowns were fabricated via CAD/CAM and luted onto a dentin analogue material using resin cement following the manufacturer's instructions. Then, the different crown regions were isolated with paraffin oil for the absence of chemical adhesion according to four experimental groups (n = 15): Shoulder; Shoulder + Axial; Fully isolated; and Control (no insulation/fully bonded). Load to failure tests (n = 3) were run to determine cyclic fatigue parameters, and the specimens were subsequently submitted to a cyclic fatigue test (n = 12) (initial load 200 N for 5000 cycles, step 100 N, 15,000 cycles/step, frequency 20 Hz) until cracks were observed, and later fracture. The data were analyzed by Kaplan-Meier + Mantel-Cox post-hoc tests for both outcomes (cracks and fracture). Fractographic, cross-sectional surface, and finite element (FEA) analyzes were performed. RESULTS When it comes to crack occurrence when the chemical adhesion to the occlusal surface is compromised, there is worsening (p < 0.05) in fatigue behavior compared to groups where the occlusal portion of the crown is still bonded. Considering fracture occurrence, there was no difference (p > 0.05) among the tested groups. All cracks occurred in the occlusal portion, first as a radial crack at the ceramic intaglio surface, and posteriorly unleashing a Hertzian cone crack at the top surface, resulting in fractures on the frontal walls. The interface analysis showed no interference of the insulating agent. FEA showed that as the isolated areas increased, there was also an increase in both tensile and shear stresses concentration in the crown and in the cement layer. CONCLUSION The chemical adhesion between cement and ceramic is essential for better fatigue behavior of lithium disilicate crowns with a simplified anatomy, especially in the occlusal portion, but the restoration performance is impaired when such adhesion is compromised. There is an increase in crown and cement stress concentration with the progressive loss of chemical bonding of the crown's walls.
Collapse
Affiliation(s)
- Lucas Saldanha da Rosa
- MSciD and PhD Post-Graduate Program in Oral Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | - Helder Callegaro Velho
- MSciD and PhD Post-Graduate Program in Oral Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | - João Paulo Mendes Tribst
- Academic Centre for Dentistry Amsterdam (ACTA), Department of Oral Regenerative Medicine, University of Amsterdam and Vrije Universiteit Amsterdam, 1081 LA, Amsterdam, the Netherlands.
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Oral Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | - Cornelis Johannes Kleverlaan
- Academic Centre for Dentistry Amsterdam (ACTA), Department of Dental Material Sciences, University of Amsterdam and Vrije Universiteit Amsterdam, 1081 LA, Amsterdam, the Netherlands.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Post-Graduate Program in Oral Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| |
Collapse
|
5
|
Wang B, Fan J, Wang L, Xu B, Wang L, Chai L. Onlays/partial crowns versus full crowns in restoring posterior teeth: a systematic review and meta-analysis. Head Face Med 2022; 18:36. [PMID: 36411462 PMCID: PMC9677648 DOI: 10.1186/s13005-022-00337-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 10/20/2022] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Tooth-colored onlays and partial crowns for posterior teeth have been used increasingly in clinics. However, whether onlays/partial crowns could perform as well as full crowns in the posterior region was still not evaluated thoroughly. METHODS A literature search was conducted without language restrictions in Pubmed, Embase, Cochrane Central Register of Controlled Trial and Web of science until September 2021. RCTs, prospective and retrospective observational studies with a mean follow-up of 1 year were selected. Cochrane Collaboration's tool was adopted for quality assessment of the RCT. The quality of observational studies was evaluated following Newcastle-Ottawa scale. The random-effects and fixed-effects model were employed for meta-analysis. RESULTS Four thousand two hundred fifty-seven articles were initially searched. Finally, one RCT was identified for quality assessment and five observational studies for qualitative synthesis and meta-analysis. The RCT was of unclear risk of bias while five observational studies were evaluated as low risk. The meta-analysis indicated no statistically significant difference in the survival between onlays/partial crowns and full crowns after 1 year (OR = 0.55, 95% CI: 0.02-18.08; I2 = 57.0%; P = 0.127) and 3 years (OR = 0.65, 95% CI: 0.20-2.17; I2 = 0.0%; P = 0.747). For the success, onlays/partial crowns performed as well as crowns (OR = 0.58, 95% CI: 0.20-1.72; I2 = 0.0%; P = 0.881) at 3 years. No significant difference of crown fracture existed between the two methods (RD = 0.00, 95% CI: - 0.03-0.03; I2 = 0.0%; P = 0.972). CONCLUSIONS Tooth-colored onlays/partial crowns performed as excellently as full crowns in posterior region in a short-term period. The conclusions should be further consolidated by RCTs with long-term follow-up.
Collapse
Affiliation(s)
- Bingjie Wang
- grid.203507.30000 0000 8950 5267Department of Stomatology, The Affiliated People’s Hospital of Ningbo University (Ningbo Yinzhou People’s Hospital), No.251, Baizhang Road(E), Ningbo, 315000 China
| | - Jiayan Fan
- grid.459833.00000 0004 1799 3336Department of Stomatology, Ningbo No.2 Hospital, Ningbo, 315000 China
| | - Lutao Wang
- grid.459833.00000 0004 1799 3336Department of Stomatology, Ningbo No.2 Hospital, Ningbo, 315000 China
| | - Bin Xu
- grid.459833.00000 0004 1799 3336Department of Stomatology, Ningbo No.2 Hospital, Ningbo, 315000 China
| | - Liang Wang
- grid.459833.00000 0004 1799 3336Department of Stomatology, Ningbo No.2 Hospital, Ningbo, 315000 China
| | - Luyi Chai
- grid.203507.30000 0000 8950 5267Department of Stomatology, The Affiliated People’s Hospital of Ningbo University (Ningbo Yinzhou People’s Hospital), No.251, Baizhang Road(E), Ningbo, 315000 China
| |
Collapse
|
6
|
Chen Y, Lee JKY, Kwong G, Pow EHN, Tsoi JKH. Morphology and fracture behavior of lithium disilicate dental crowns designed by human and knowledge-based AI. J Mech Behav Biomed Mater 2022; 131:105256. [DOI: 10.1016/j.jmbbm.2022.105256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 04/20/2022] [Accepted: 04/25/2022] [Indexed: 11/25/2022]
|
7
|
Comparative Stress Analysis of Polyetherketoneketone (PEKK) Telescopic Crowns Supported by Different Primary Crown Materials. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12073446] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The present study aimed to investigate the stress distribution of secondary telescopic crowns made of polyetherketoneketone (PEKK) combined with different primary crown (PC) materials (Zirconia, CoCr, Titanium, and PEKK) using finite element analysis. The geometric model was composed of bone tissue, periodontal ligament, root dentin, cement layer, primary crown, and secondary telescopic crown (SC). A total of four models were evaluated in which the secondary crowns were simulated in PEKK. The models were designed in CAD software and exported to the computer aided engineering software for the statistic structural analysis simulation. The materials were considered isotropic, with linear behavior and elastic properties. The model was fixed in the bone base and the load was applied at the occlusal surface of the crowns with 600 N. The results were required in von-Mises stress for the primary crown, secondary crown, cement layer, and Equivalent Strain to the periodontal ligament and bone tissue. Results show that the material influenced the stress distribution. The higher the PC elastic modulus, the higher the stress magnitude on the SC and cement layer. In the present study, the use of milled high-density polymer for primary crown presented a promising biomechanical behavior as an alternative material for double-crown design.
Collapse
|