1
|
Rhodes D, Carcelain G, Keeney M, Parizot C, Benjamins D, Genesta L, Zhang J, Rohrbach J, Lawrie D, Glencross DK. Assessment of the AQUIOS flow cytometer - An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration. Afr J Lab Med 2019; 8:804. [PMID: 31850159 PMCID: PMC6909423 DOI: 10.4102/ajlm.v8i1.804] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Accepted: 03/18/2019] [Indexed: 11/16/2022] Open
Abstract
Background Flow cytometry has been the approach of choice for enumerating and documenting CD4-cell decline in HIV monitoring. Beckman Coulter has developed a single platform test for CD4+ T-cell lymphocyte count and percentage using PanLeucogating (PLG) technology on the automated AQUIOS flow cytometer (AQUIOS PLG). Objectives This study compared the performance of AQUIOS PLG with the Flowcare PLG method and performed a reference interval for comparison with those previously published. Methods The study was conducted between November 2014 and March 2015 at 5 different centres located in Canada; Paris, France; Lyon, France; the United States; and South Africa. Two-hundred and forty samples from HIV-positive adult and paediatric patients were used to compare the performances of AQUIOS PLG and Flowcare PLG on a FC500 flow cytometer (Flowcare PLG) in determining CD4+ absolute count and percentage. A reference interval was determined using 155 samples from healthy, non-HIV adults. Workflow was investigated testing 440 samples over 5 days. Results Mean absolute and relative count bias between AQUIOS PLG and Flowcare PLG was −41 cells/µL and −7.8%. Upward and downward misclassification at various CD4 thresholds was ≤ 2.4% and ≤ 11.1%. The 95% reference interval (2.5th – 97.5th) for the CD4+ count was 453–1534 cells/µL and the percentage was 30.5% – 63.4%. The workflow showed an average number of HIV samples tested as 17.5 per hour or 122.5 per 8-hour shift for one technician, including passing quality controls. Conclusion The AQUIOS PLG merges desirable aspects from conventional flow cytometer systems (high throughput, precision and accuracy, external quality assessment compatibility) with low technical operating skill requirements for automated, single platform systems.
Collapse
Affiliation(s)
- Daniel Rhodes
- Clinical Affairs, Beckman Coulter Immunotech, Marseille, France
| | | | - Mike Keeney
- Lawson Health Research Institute, London Health Sciences Centre and St. Joseph's Health Care, Victoria Hospital, London, Ontario, Canada
| | | | | | | | - Jin Zhang
- Life Science Flow Cytometry, Beckman Coulter Incorporated, Miami, Florida, United States
| | - Justin Rohrbach
- Clinical affairs, Beckman Coulter Incorporated, Miami, Florida, United States
| | - Denise Lawrie
- National Health Laboratory Service, Charlotte Maxeke Johannesburg Academic Hospital, Johannesburg, South Africa
| | - Deborah K Glencross
- Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa.,National Health Laboratory Services, Johannesburg, South Africa
| |
Collapse
|
2
|
Silva ED, Oliveira BC, Oliveira AP, Santos WJT, Diniz GT, de Melo Neto OP, Costa CHN, Silva MRB, Andrade LD, Medeiros ZM, Pereira VRA. Performance evaluation of anti-fixed Leishmania infantum promastigotes immunoglobulin G (IgG) detected by flow cytometry as a diagnostic tool for visceral Leishmaniasis. J Immunol Methods 2019; 469:18-25. [PMID: 30817916 DOI: 10.1016/j.jim.2019.02.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 02/08/2019] [Accepted: 02/22/2019] [Indexed: 12/30/2022]
Abstract
Visceral Leishmaniasis (VL) is a severe disease, caused by the protozoans Leishmania infantum and L. donovani that is widely diagnosed using serological tools. These, however, have limitations in performance that limit their use for the correct identification of the cases. This study aimed to evaluate the performance of flow cytometry with fixed parasites for VL diagnosis, comparing it with four other serological tests. Samples from two endemic VL regions in Brazil, diagnosed by direct examination (DG1) and by at least two or one standard serological test (DG2 and DG3, respectively), as well as patients with chronic Chagas' disease (CG1) and healthy controls (CG2) were used in this study. The flow cytometry results were expressed as levels of IgG reactivity, based on the percentage of positive fluorescent parasites (PPFP). Using a 1:4096 serum dilution, a ROC curve analysis of the serum titration on flow cytometry has indicated a PPFP of 2% as the cutoff point to segregate positive and negative results. In the present study, flow cytometry had the best performance for DG1 (sensitivity of 96%) while rK39 (imunocromagraphic rapid test) and DAT (Direct agglutination test) were also associated with high sensitivity and specificity. The substantial agreement and kappa indexes observed suggested similar performances between these two tests and flow cytometry. IFAT (Immunofluorescent antibody test) and ELISA (Enzyme-linked immunosorbent assay) had lower performances and the lower values of agreement with flow cytometry. Together, these findings suggest that although adjustments are needed in order to reduce cross reactivity with other trypanosomatids, flow cytometry has the potential to be a safe serological alternative for the diagnosis of VL.
Collapse
Affiliation(s)
- Elis D Silva
- Fundação Oswaldo Cruz (Fiocruz-Pernambuco), Instituto Aggeu Magalhães, Recife, Pernambuco, Brazil.
| | - Beatriz C Oliveira
- Fundação Oswaldo Cruz (Fiocruz-Pernambuco), Instituto Aggeu Magalhães, Recife, Pernambuco, Brazil
| | - Andresa P Oliveira
- Fundação Oswaldo Cruz (Fiocruz-Pernambuco), Instituto Aggeu Magalhães, Recife, Pernambuco, Brazil
| | - Wagner J T Santos
- Fundação Oswaldo Cruz (Fiocruz-Pernambuco), Instituto Aggeu Magalhães, Recife, Pernambuco, Brazil
| | - George T Diniz
- Fundação Oswaldo Cruz (Fiocruz-Pernambuco), Instituto Aggeu Magalhães, Recife, Pernambuco, Brazil
| | - Osvaldo P de Melo Neto
- Fundação Oswaldo Cruz (Fiocruz-Pernambuco), Instituto Aggeu Magalhães, Recife, Pernambuco, Brazil
| | - Carlos H N Costa
- Instituto de Doenças Tropicais Natan Portella (IDTNP), Teresina, Piaui, Brazil
| | | | - Luiz D Andrade
- Fundação Oswaldo Cruz (Fiocruz-Pernambuco), Instituto Aggeu Magalhães, Recife, Pernambuco, Brazil
| | - Zulma M Medeiros
- Fundação Oswaldo Cruz (Fiocruz-Pernambuco), Instituto Aggeu Magalhães, Recife, Pernambuco, Brazil; Faculdade de Ciências Médicas, Universidade de Pernambuco, Recife, Brazil
| | - Valéria R A Pereira
- Fundação Oswaldo Cruz (Fiocruz-Pernambuco), Instituto Aggeu Magalhães, Recife, Pernambuco, Brazil
| |
Collapse
|
3
|
Kestens L, Mandy F. Issue Highlights - November 2017 (92:B6). CYTOMETRY PART B-CLINICAL CYTOMETRY 2018; 92:433-436. [PMID: 29077268 DOI: 10.1002/cyto.b.21599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
4
|
Shapiro HM, Apte SH, Chojnowski GM, Hänscheid T, Rebelo M, Grimberg BT. Cytometry in malaria--a practical replacement for microscopy? ACTA ACUST UNITED AC 2014; Chapter 11:11.20.1-11.20.23. [PMID: 23835802 DOI: 10.1002/0471142956.cy1120s65] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Malaria, caused by protozoan Plasmodium parasites, kills ~800,000 people each year. Exact figures are uncertain because presumptive diagnoses are often made without identifying parasites in patients' blood either by microscopy, using Giemsa's century-old stain, or by simpler tests that are ultimately dependent on microscopy for quality control. Microscopy itself relies on trained observers' ability to detect subtle morphological features of parasitized red blood cells, only a few of which may be present on a slide. Quantitative and objective flow cytometric measurements of cellular constituents such as DNA, RNA, and the malaria pigment hemozoin are now useful in research in malaria biology and pharmacology, and can provide more reliable identification of parasite species and developmental stages and better detection of low-density parasitemia than could microscopy. The same measurements can now be implemented in much smaller, simpler, cheaper imaging cytometers, potentially providing a more accurate and precise diagnostic modality.
Collapse
|
5
|
Lawrie D, Coetzee LM, Glencross DK. A model for continuous quality control incorporating sample-to-sample assessment of optical alignment, fluorescence sensitivity, and volumetric operation of flow cytometers. CYTOMETRY PART B-CLINICAL CYTOMETRY 2010; 78:201-10. [PMID: 20419764 DOI: 10.1002/cyto.b.20520] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Bead count rate (BCR) monitoring successfully identifies pipetting error during single platform CD4 enumeration. Despite rigorous prescribed quality control performed, preliminary data suggested that BCR outliers could also be attributed to occasional failure of flow cytometric volumetric operation. The aim of this report was to use counting beads in a model of continuous quality control (CQC) to monitor overall flow cytometric performance (laser alignment, fluorescence stability and volumetric operation). METHODS The proposed CQC model used FlowCheck and IMMUNOTROL blood controls daily. Extended monitoring of fluidics (FPV; beads and sheath only) and sample preparation (SPV; blood, IMMUNOPREP and beads) was done daily on five flow cytometers over five consecutive days prior to testing patient samples. Sample-to-sample CQC included monitoring BCR, selected time/fluorescence histograms (Time vs. Count; Time vs. Fluorescence and Forward Scatter vs. Fluorescence) and full peak coefficient of variation (FPCV) for 2000 samples tested. RESULTS Prescribed quality controls showed Half Peak CV values of <2% (FlowCheck) with Immunotrol within 0.5SD of the target means. Laser stability was confirmed (FPCV values <2%). However, fluidics (volumetric operation) fluctuated as indicated by a 3.2% BCR outlier rate of 2,000 samples tested (minus pipetting error) despite optimal fluidics performance verified at start-up (FPV CV < 3%). CONCLUSIONS Sustained laser stability was confirmed with Time vs. Fluorescence histograms, but Time vs. Count histograms were insufficient to detect intermittent volumetric failure. The proposed CQC model, incorporating BCR monitoring with time/fluorescence histograms and FPCV monitoring can identify all volumetric inconsistencies in real-time.
Collapse
Affiliation(s)
- Denise Lawrie
- National Health Laboratory Services and Department of Molecular Medicine and Haematology, Faculty of Health Sciences, University of the Witwatersrand, Parktown, Johannesburg, South Africa
| | | | | |
Collapse
|
6
|
Oakey J, Applegate RW, Arellano E, Di Carlo D, Graves SW, Toner M. Particle focusing in staged inertial microfluidic devices for flow cytometry. Anal Chem 2010; 82:3862-7. [PMID: 20373755 DOI: 10.1021/ac100387b] [Citation(s) in RCA: 129] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Microfluidic inertial focusing has been demonstrated to be an effective method for passively positioning microparticles and cells without the assistance of sheath fluid. Because inertial focusing produces well-defined lateral equilibrium particle positions in addition to highly regulated interparticle spacing, its value in flow cytometry has been suggested. Particle focusing occurs in straight channels and can be manipulated through cross sectional channel geometry by the introduction of curvature. Here, we present a staged channel design consisting of both curved and straight sections that combine to order particles into a single streamline with longitudinal spacing. We have evaluated the performance of these staged inertial focusing channels using standard flow cytometry methods that make use of calibration microspheres. Our analysis has determined the measurement precision and resolution, as a function of flow velocity and particle concentration that is provided by these channels. These devices were found to operate with increasing effectiveness at higher flow rates and particle concentrations, within the examined ranges, which is ideal for high throughput analysis. Further, the prototype flow cytometer equipped with an inertial focusing microchannel matched the resolution provided by a commercial hydrodynamic focusing flow cytometer. Most notably, our analysis indicates that the inertial focusing channels virtually eliminated particle coincidence at the analysis point. These properties suggest a potentially significant role for inertial focusing in the development of inexpensive flow cytometry-based diagnostics and in applications requiring the analysis of high particle concentrations.
Collapse
Affiliation(s)
- John Oakey
- BioMEMS Resource Center, Center for Engineering in Medicine and Surgical Services, Massachusetts General Hospital, Shriners Hospital for Children and Harvard Medical School, Boston, Massachusetts 02114, USA
| | | | | | | | | | | |
Collapse
|
7
|
Alamooti AA, Ardalan FA, Abdolahi A, Zeidi M, Firouzjaie F. Determination of lymphocyte subsets reference values in healthy Iranian men by a single platform flow cytometric method. Cytometry A 2010; 77:890-4. [DOI: 10.1002/cyto.a.20912] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
8
|
Janossy G, Mandy F. Translational medicine as implementation science in the field of monitoring HIV and TB. New concepts emanating from resource-poor countries. CYTOMETRY PART B-CLINICAL CYTOMETRY 2010; 78:183-7. [DOI: 10.1002/cyto.b.20527] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
9
|
Lizard G. Diagnosing HIV infection using flow cytometry: From antigenic analyses to a specifically dedicated bead-based assay to measure viral load. Cytometry A 2009; 75:172-4. [DOI: 10.1002/cyto.a.20694] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
10
|
Stevens W, Gelman R, Glencross DK, Scott LE, Crowe SM, Spira T. Evaluating new CD4 enumeration technologies for resource-constrained countries. Nat Rev Microbiol 2008; 6:S29-38. [PMID: 22745957 DOI: 10.1038/nrmicro2000] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
11
|
Walker C, Barnett D. Flow rate calibration for absolute cell counting rationale and design. ACTA ACUST UNITED AC 2008; Chapter 6:Unit6.24. [PMID: 18770842 DOI: 10.1002/0471142956.cy0624s36] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
There is a need for absolute leukocyte enumeration in the clinical setting, and accurate, reliable (and affordable) technology to determine absolute leukocyte counts has been developed. Such technology includes single platform and dual platform approaches. Derivations of these counts commonly incorporate the addition of a known number of latex microsphere beads to a blood sample, although it has been suggested that the addition of beads to a sample may only be required to act as an internal quality control procedure for assessing the pipetting error. This unit provides the technical details for undertaking flow rate calibration that obviates the need to add reference beads to each sample. It is envisaged that this report will provide the basis for subsequent clinical evaluations of this novel approach.
Collapse
Affiliation(s)
- Clare Walker
- Royal Hallamshire Hospital, Sheffield, United Kingdom
| | | |
Collapse
|
12
|
Janossy G, Shapiro H. Simplified cytometry for routine monitoring of infectious diseases. CYTOMETRY PART B-CLINICAL CYTOMETRY 2008; 74 Suppl 1:S6-10. [PMID: 18228555 DOI: 10.1002/cyto.b.20405] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The interacting epidemics of HIV/AIDS, tuberculosis (TB) and malaria in resource-poor areas of the world have created a critical need for rapid, simple, affordable apparatus and tests that will permit patients with these diseases to be promptly diagnosed and properly managed. As documented in the current issue of Clinical Cytometry, complex flow cytometric analyses used in affluent countries for CD4+ T cell counting in HIV/AIDS have been simplified, introduced, and quality assessed in resource-restricted countries of Africa and the Caribbean, where simple gating protocols such as panleucogating now provide accurate and precise CD4+ T cell counts on a large scale. CD4/CD8 ratios in infants may replace more expensive molecular tests for HIV infection; simplified flow cytometry is also compatible with HIV viral load-associated lymphocyte activation tests and with antigen-specific cellular immune response assays that rapidly diagnose active TB in both HIV-negative and HIV-TB co-infected individuals. In addition, it is becoming evident that smaller, much less expensive fluorescence imaging cytometers can be used for CD4 counting, immunophenotyping, and hematology and for other applications such as diagnosis and drug-susceptibility testing of TB and diagnosis of malaria. With the gradual, organized expansion of the much-needed diagnostic networks in the underprivileged countries, the most cost-effective apparatus may be one capable of performing tests for all the three diseases mentioned. The most sustainable systems will be those that can be assembled and maintained, to the greatest extent possible, in the countries where they will be used.
Collapse
Affiliation(s)
- George Janossy
- Royal Free and University College Medical School, University College London, NW3, United Kingdom.
| | | |
Collapse
|
13
|
Janossy G. The changing pattern of "smart" flow cytometry (S-FC) to assist the cost-effective diagnosis of HIV, tuberculosis, and leukemias in resource-restricted conditions. Biotechnol J 2008; 3:32-42. [PMID: 18064612 DOI: 10.1002/biot.200700200] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
There is a need to introduce cytometry into areas of the globe that have remained virtually untouched by modern laboratory medicine. With the demand to carry out tests on 100,000 s of individuals requiring antiretroviral therapy (ART), flow cytometry must remain simple and cost-effective - while being sustainable and industry supported as well as proven by quality assessment (QA). This outlook is referred to as "smart flow cytometry" (S-FC). There are five main areas where the power of S-FC is demonstrated. These are: (i) the use of CD45 to assist precise cell counting in blood and tissue samples; (ii) the primary CD4 gating to count CD4+ T cells in patients waiting for ART, including the combination (i) and (ii) in the panleucogating (PLG) protocol; (iii) monitoring of human immunodeficiency virus (HIV+) patients during ART by the decreasing levels of lymphocyte activation in a CD8/CD38 test - leading to economies of viral-load assays; (iv) in tuberculosis and HIV-TB coinfections the use of TB-antigen-stimulated cytokine-synthetic CD4+ T cells to identify active disease; and (v) the utilization of "minimal residual disease (MRD)-Lite" technology in patients 19 days after the start of antileukemic therapy to detect MRD. These methods of S-FC have been successfully introduced in "resource-restricted" countries with international and local QA.
Collapse
Affiliation(s)
- George Janossy
- Royal Free and University College Medical School, University College London, London, UK.
| |
Collapse
|
14
|
Mandy F, Janossy G, Bergeron M, Pilon R, Faucher S. Affordable CD4 T-cell enumeration for resource-limited regions: A status report for 2008. CYTOMETRY PART B-CLINICAL CYTOMETRY 2008; 74 Suppl 1:S27-39. [DOI: 10.1002/cyto.b.20414] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
15
|
Shapiro HM, Perlmutter NG. Killer applications: Toward affordable rapid cell-based diagnostics for malaria and tuberculosis. CYTOMETRY PART B-CLINICAL CYTOMETRY 2008; 74 Suppl 1:S152-64. [DOI: 10.1002/cyto.b.20401] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
16
|
Habbersett RC, Naivar MA, Woods TA, Goddard GR, Graves SW. Evaluation of a green laser pointer for flow cytometry. Cytometry A 2007; 71:809-17. [PMID: 17712796 DOI: 10.1002/cyto.a.20454] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Flow cytometers typically incorporate expensive lasers with high-quality (TEM00) output beam structure and very stable output power, significantly increasing system cost and power requirements. Red diode lasers minimize power consumption and cost, but limit fluorophore selection. Low-cost DPSS laser pointer modules could possibly offer increased wavelength selection but presumed emission instability has limited their use. A $160 DPSS 532 nm laser pointer module was first evaluated for noise characteristics and then used as the excitation light source in a custom-built flow cytometer for the analysis of fluorescent calibration and alignment microspheres. Eight of ten modules tested were very quiet (RMS noise < or = 0.6% between 0 and 5 MHz). With a quiet laser pointer module as the light source in a slow-flow system, fluorescence measurements from alignment microspheres produced CVs of about 3.3%. Furthermore, the use of extended transit times and < or =1 mW of laser power produced both baseline resolution of all 8 peaks in a set of Rainbow microspheres, and a detection limit of <20 phycoerythrin molecules per particle. Data collected with the transit time reduced to 25 micros (in the same instrument but at 2.4 mW laser output) demonstrated a detection limit of approximately 75 phycoerythrin molecules and CVs of about 2.7%. The performance, cost, size, and power consumption of the tested laser pointer module suggests that it may be suitable for use in conventional flow cytometry, particularly if it were coupled with cytometers that support extended transit times.
Collapse
Affiliation(s)
- Robert C Habbersett
- The National Flow Cytometry Resource, Bioscience Division, Los Alamos National Laboratory, Los Alamos, NM 87545, USA
| | | | | | | | | |
Collapse
|
17
|
Abayomi A. The human immunodeficiency virus epidemic: a race against time for millions and the role of flow cytometry. A Caribbean and resource-constrained country perspective. CYTOMETRY PART B-CLINICAL CYTOMETRY 2007; 72:478-81. [PMID: 17421027 DOI: 10.1002/cyto.b.20110] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
There is a race against time for millions in the world today. Both the technology and the manpower are currently available to deliver the services that are required to meet the needs of the 40 million people currently living with HIV/AIDS, but at what price? The reality is therefore that we are a long shot away from this realization. What are the facts and why have we not achieved even the simplest deadlines set by the World Health Organization (WHO)? Are these objectives realistic? What role does hard science have to play in the search for cost-effective solutions and futuristic effective options? To stem this unrelenting epidemic and convert the natural history of the disorder in those already living with the virus into one of chronicity, rather than one characterized by a dehumanizing and stigmatized death, requires a global commitment at all levels. This discussion examines the reality and offers a snapshot of capacity and experiences in the developing world. Crucially, it looks at the immediate and long term role of flow cytometry in the expanded care and treatment programs for developing nations.
Collapse
Affiliation(s)
- Akin Abayomi
- Department of Internal Medicine, Tygerberg Academic Hospital, Faculty of Medical Sciences, Stellenbosch University, Cape Town, South Africa.
| |
Collapse
|
18
|
Fryland M, Chaillet P, Zachariah R, Barnaba A, Bonte L, Andereassen R, Charrondière S, Teck R, Didakus O. The Partec CyFlow Counter® could provide an option for CD4+ T-cell monitoring in the context of scaling-up antiretroviral treatment at the district level in Malawi. Trans R Soc Trop Med Hyg 2006; 100:980-5. [PMID: 16542690 DOI: 10.1016/j.trstmh.2005.11.014] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2005] [Revised: 11/29/2005] [Accepted: 11/29/2005] [Indexed: 11/23/2022] Open
Abstract
A study was conducted in rural Malawi to verify (a) whether the Partec CyFlow Counter((R)) for CD4+ T-cell lymphocyte counting in HIV-positive individuals could be introduced into a district hospital laboratory and (b) whether it would produce CD4 counts of acceptable quality. CD4+ cell counting was performed using the Partec CyFlow Counter and the results were compared with a reference method (FACsCount). A total of 311 blood samples were analysed and the correlation coefficient for the CyFlow Counter was 0.92 (95% CI 0.89-0.95). Mean CD4 counts using the Partec and the reference methods were 308.2 cells/microl and 316.9 cells/microl, respectively. The mean difference in CD4 count values was -8.68 cells/microl (95% CI -18.8 to 1.4). Mean intra-run variation was -6.84 cells/microl (95% CI -12.9 to 0.79). In the district laboratory setting, the instrument could accommodate up to 75 blood samples per technician per day. After being trained, local laboratory staff found the CyFlow Counter procedures simple to run and the instrument easy to manipulate. The Partec CyFlow Counter produces sufficiently reliable results and the instrument appears robust under field conditions. It could provide a new option for introducing routine CD4+ cell monitoring at the district level in the context of scaling-up antiretroviral therapy in Malawi.
Collapse
Affiliation(s)
- M Fryland
- Médecins sans Frontières-Luxembourg, Thyolo District, Malawi
| | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Walker CL, Whitby L, Granger V, Storie I, Reilly JT, Barnett D. Flow rate calibration. III. The use of stabilized biostandards to calibrate the flow rate and calculate absolute CD4+ T-cell counts. CYTOMETRY PART B-CLINICAL CYTOMETRY 2006; 70:154-62. [PMID: 16572418 DOI: 10.1002/cyto.b.20103] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND We have previously reported a flow rate calibration method for the determination of absolute CD4(+) T-lymphocyte counts that removes the need for the addition of latex beads to each sample. However, a limitation with this approach is that a calibration factor (CF) needs to be applied to adjust for differences in viscosity between latex bead suspensions and biological specimens. We have also demonstrated the value of using stabilized whole blood samples in external quality assessment (EQA) studies; such samples have a stable absolute lymphocyte count for over 1 year, at 4 degrees C. It was successfully demonstrated that this material can be used as a flow rate biocalibration (FRB) material for use as a flow cytometric control to provide a sample with a known CD4(+) T-lymphocyte count. Such material has advantages over latex bead technology as it can act as a full process control as well as having the same matrix and viscosity characteristics as the test material, thus removing the need for a CF. METHODS In this study, we have analyzed 268 consecutive normal, abnormal, and HIV(+) samples using FRB, incorporating the PanLeucoGating approach and compared this to the MultiSet method, defined as the predicate. RESULTS Percentage similarity statistics revealed the following: 0-3,000 CD4(+) cells/mul mean percentage difference (MPD; bias) 1.2%, 95% CI of 5.6-8%; 0-200 CD4(+) cells/microl MPD of 1.25%, 95% CI of 11.63-14.13%; 201-500 CD4(+) cells/microl MPD of 1%, 95% CI of 4.6-6.6%. DISCUSSION This study demonstrates that stabilized whole blood can be used for FRB. It has the advantage of being a full process control, in addition to costing less than latex beads with highly comparable results. As bench top flow cytometers are extremely stable, this is a low cost and robust alternative to bead based methods for generating absolute CD4 counts.
Collapse
Affiliation(s)
- Clare L Walker
- UK NEQAS for Leucocyte Immunophenotyping, Department of Haematology, Royal Hallamshire Hospital, Sheffield
| | | | | | | | | | | |
Collapse
|
20
|
Schmidt B, Fujimura SH, Martin JN, Levy JA. Variations in plasmacytoid dendritic cell (PDC) and myeloid dendritic cell (MDC) levels in HIV-infected subjects on and off antiretroviral therapy. J Clin Immunol 2006; 26:55-64. [PMID: 16418803 DOI: 10.1007/s10875-006-8401-3] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2005] [Accepted: 09/08/2005] [Indexed: 11/26/2022]
Abstract
Plasmacytoid and myeloid dendritic cells are reduced in AIDS patients. The number of these circulating cells was assessed cross-sectionally and longitudinally in 27 uninfected and 72 HIV-infected subjects on and off antiretroviral therapy. The plasmacytoid dendritic cell numbers were significantly reduced in the HIV-infected subjects compared to controls (p < 0.001). This reduction correlated directly with CD4+ cell counts (p < 0.001) and inversely with viral load (p < 0.001). These associations were found to a lesser degree for the myeloid dendritic cells. Intra-assay variability of these dendritic cell counts was < 10%. Antiretroviral therapy significantly increased plasmacytoid dendritic cell (p < 0.001) and CD4+ cell (p = 0.05) counts at 8 months by 76.9% and 19%, respectively. The plasmacytoid dendritic cell levels responded more readily to viral load increases and decreases than CD4+ cells. Circulating plasmacytoid dendritic cells may provide important additional information about immune function in HIV-infected subjects receiving or not receiving antiretroviral therapy.
Collapse
Affiliation(s)
- Barbara Schmidt
- Division Hematology/Oncology, Department of Medicine, University of California, San Francisco, California 94143-1270, USA
| | | | | | | |
Collapse
|
21
|
|
22
|
Goddard G, Martin JC, Graves SW, Kaduchak G. Ultrasonic particle-concentration for sheathless focusing of particles for analysis in a flow cytometer. Cytometry A 2006; 69:66-74. [PMID: 16419065 DOI: 10.1002/cyto.a.20205] [Citation(s) in RCA: 80] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND The development of inexpensive small flow cytometers is recognized as an important goal for many applications ranging from medical uses in developing countries for disease diagnosis to use as an analytical platform in support of homeland defense. Although hydrodynamic focusing is highly effective at particle positioning, the use of sheath fluid increases assay cost and reduces instrument utility for field and autonomous remote operations. METHODS This work presents the creation of a novel flow cell that uses ultrasonic acoustic energy to focus small particles to the center of a flowing stream for analysis by flow cytometry. Experiments using this flow cell are described wherein its efficacy is evaluated under flow cytometric conditions with fluorescent microspheres. RESULTS Preliminary laboratory experiments demonstrate acoustic focusing of flowing 10-microm latex particles into a tight sample stream that is approximately 40 microm in diameter. Prototype flow cytometer measurements using an acoustic-focusing flow chamber demonstrated focusing of a microsphere sample to a central stream approximately 40 microm in diameter, yielding a definite fluorescence peak for the microspheres as compared with a broad distribution for unfocused microspheres. CONCLUSIONS The flow cell developed here uses acoustic focusing, which inherently concentrates the sample particles to the center of the sample stream. This method could eliminate the need for sheath fluid, and will enable increased interrogation times for enhanced sensitivity, while maintaining high particle-analysis rates. The concentration effect will also enable the analysis of extremely dilute samples on the order of several particles per liter, at analysis rates of a few particles per second. Such features offer the possibility of a truly versatile low-cost portable flow cytometer for field applications.
Collapse
Affiliation(s)
- Gregory Goddard
- National Flow Cytometry Resource, Los Alamos National Laboratory, PO Box 1663, Los Alamos, NM 87545, USA.
| | | | | | | |
Collapse
|
23
|
Bussmann H, Wester CW, Masupu KV, Peter T, Gaolekwe SM, Kim S, Reich AM, Ahn S, Wu Y, Thior I, Essex M, Marlink R. Low CD4+ T-lymphocyte values in human immunodeficiency virus-negative adults in Botswana. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2005; 11:930-5. [PMID: 15358655 PMCID: PMC515279 DOI: 10.1128/cdli.11.5.930-935.2004] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
CD4+-lymphocyte counts (LCs) play a crucial role in the management and monitoring of HIV infection. Variability in CD4+ LCs has been reported to occur as a result of measurement techniques and/or biological variations. We report on the CD4+ LCs of healthy human immunodeficiency virus (HIV)-seronegative adults in Botswana. Samples were obtained from HIV-seronegative blood donors. The median CD4+ LC was 726 cells/mm3 (for females, 782 cells/mm3; for males, 698 cells/mm3). The median CD8+ LC was 488 cells/mm3 (for females, 494 cells/mm3; for males, 485 cells/mm3). The median CD4+-to-CD8+ ratio was 1.57 (for females, 1.66; for males, 1.51). Our findings of low CD4+ LCs among HIV-negative adults in Botswana are significant and have important implications for the management of HIV disease in the population of this sub-Saharan African country.
Collapse
|
24
|
Storie I, Sawle A, Goodfellow K, Whitby L, Granger V, Ward RY, Peel J, Smart T, Reilly JT, Barnett D. Perfect count: a novel approach for the single platform enumeration of absolute CD4+ T-lymphocytes. CYTOMETRY PART B-CLINICAL CYTOMETRY 2004; 57:47-52. [PMID: 14696063 DOI: 10.1002/cyto.b.10065] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND The derivation of reliable CD4(+) T lymphocyte counts is vital for the monitoring of disease progression and therapeutic effectiveness in HIV(+) individuals. Flow cytometry has emerged as the method of choice for CD4(+) T lymphocyte enumeration, with single-platform technology, coupled with reference counting beads, fast becoming the "gold standard." However, although single-platform, bead-based, sample acquisition requires the ratio of beads to cells to remain unchanged, there is no available method, until recently, to monitor this. METHODS Perfect Count beads have been developed to address this issue and to incorporate two bead populations, with different densities, to allow the detection of inadequate mixing. Comparison of the relative proportions of both beads with the manufacture's defined limits enables an internal QC check during sample acquisition. In this study, we have compared CD4(+) T lymphocyte counts, obtained from 104 HIV(+) patients, using TruCount beads with MultiSet software (defined as the predicated method) and the new Perfect Count beads, incorporating an in house sequential gating strategy. RESULTS We have demonstrated an excellent degree of correlation between the predicate method and the Perfect Count system (r(2) = 0.9955; Bland Altman bias +27 CD4(+) T lymphocytes/microl). CONCLUSIONS The Perfect Count system is a robust method for performing single platform absolute counts and has the added advantage of having internal QC checks. Such an approach enables the operator to identify potential problems during sample preparation, acquisition and analysis.
Collapse
Affiliation(s)
- Ian Storie
- UK NEQAS for Leucocyte Immunophenotyping, Royal Hallamshire Hospital, Sheffield, United Kingdom
| | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Cassens U, Göhde W, Kuling G, Gröning A, Schlenke P, Lehman LG, Traoré Y, Servais J, Henin Y, Reichelt D, Greve B. Simplified Volumetric Flow Cytometry Allows Feasible and Accurate Determination of Cd4 T Lymphocytes in Immunodeficient Patients Worldwide. Antivir Ther 2004. [DOI: 10.1177/135965350400900309] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The determination of CD4 cells is of crucial clinical importance for patients with AIDS. However, the high costs involved represent limitations for CD4 cell counting in developing countries. In order to provide an affordable technique, we introduced a simplified volumetric counting (SVC) technique without sample manipulations and investigated it in a multicentre study. Blood samples from 434 healthy donors and immunodeficient patients were tested in eight hospital laboratories in Europe, Africa and Asia. CD4 cell counts were compared using inhouse flow cytometric methods and the SVC technique. The SVC method was performed on a low-cost flow cytometer (CyFlow SL, Partec, Münster, Germany) after 15 min antibody incubation without pre-analytic manipulations, such as washing or erythrocyte lysing procedures. Linear regression analysis demonstrated a correlation of r=0.942 (Europe), r=0.952 (Africa) and r=0.989 (Asia) between the SVC technique and the in-house methods. Bland Altman plot analysis of all patient data showed a mean bias between the two methods of +26 CD4 cells in favour of the SVC technique (measured range: 6–1905 cells/μl; median CD4 cell count: 388/μl). Three centres used the FACS-count technique (Becton-Dickinson, San José, Calif., USA) as an in-house method dispensing with pre-analytic manipulations. The comparison of SVC and FACS-count method revealed a mean bias of +32 CD4 cells/μl (median CD4 cell count: 349/μl). The accuracy of the SVC was tested on standards with known CD4 cell counts ( n=6) and was shown to be 95.2%. The low-cost device and the simplified no-lyse, no-wash test procedure reduces the costs per determination and facilitates the use of flow cytometry in developing countries.
Collapse
Affiliation(s)
- Uwe Cassens
- Institute of Transfusion Medicine, University Hospital Münster, Germany
| | - Wolfgang Göhde
- Institute of Radiation Biology, University Hospital Münster, Germany
| | - Gudrun Kuling
- Department of Internal Medicine/Haematology, Helios-Kliniken Berlin, Robert-Rössle Klinik Berlin, Germany
| | - Arndt Gröning
- Institute of Laboratory and Transfusion Medicine, University Hospital Bad Oeynhausen, Germany
| | - Peter Schlenke
- Institute of Immunology and Transfusion Medicine, University Hospital Lübeck, Germany
| | | | - Yves Traoré
- University of Ougadougou, UFR/SVT, Burkina Faso
| | - Jean Servais
- Lux Development, Treatment and Research AIDS Center Kigali, Rwanda
| | - Yvette Henin
- Institut Pasteur du Cambodge, Phnom Penh, Cambodia
| | - Doris Reichelt
- Department of Internal Medicine, University Hospital Münster, Germany
| | - Burkhard Greve
- Institute of Radiation Biology, University Hospital Münster, Germany
| |
Collapse
|
26
|
Janossy G. Clinical flow cytometry, a hypothesis-driven discipline of modern cytomics. ACTA ACUST UNITED AC 2004; 58:87-97. [PMID: 14994227 DOI: 10.1002/cyto.a.20011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- George Janossy
- HIV Immunology, Department of Immunology and Molecular Pathology, Royal Free and University College Medical School, London, United Kingdom.
| |
Collapse
|
27
|
|
28
|
Storie I, Sawle A, Goodfellow K, Whitby L, Granger V, Reilly JT, Barnett D. Flow rate calibration I: a novel approach for performing absolute cell counts. CYTOMETRY. PART B, CLINICAL CYTOMETRY 2003; 55:1-7. [PMID: 12949953 DOI: 10.1002/cyto.b.10051] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Reports suggest that flow rate (FR) is constant on bench top flow cytometers. Therefore, if FR is constant, the volume acquired in a fixed time period will also be constant, enabling absolute leucocyte counting using flow rate calibration (FRC). METHODS FR stability was ascertained on a standard FACSCalibur by counting TruCount beads suspended in phosphate buffered saline over 120 s. Studies using two lysing solutions (FACS lysing solution and PharM Lyse) and corresponding sample lysates established a lysing solution calibration factor (CF). Absolute CD4(+) T-lymphocyte counts on 10 peripheral blood samples determined using FRC were compared with the predicate method TruCount/MultiTEST, incorporating MultiSET software. Linearity studies were also performed at three different flow rates. RESULTS A high degree of linearity over a wide range of counts (50 to >1,600 CD4(+) T lymphocytes/microl) at all three pressures was observed. Importantly, there was no significant difference from the predicate method when appropriate lysing solution CF was used. CONCLUSIONS Using a simple calibration procedure and incorporation of an appropriate lysing solution CF, we show that FRC can easily be performed. The technical details that underpin this novel approach for absolute leucocyte enumeration are provided.
Collapse
Affiliation(s)
- Ian Storie
- UK NEQAS for Leucocyte Immunophenotyping, Royal Hallamshire Hospital, Sheffield, United Kingdom
| | | | | | | | | | | | | |
Collapse
|
29
|
Storie I, Sawle A, Whitby L, Goodfellow K, Granger V, Reilly JT, Barnett D. Flow rate calibration II: a clinical evaluation study using PanLeucoGating as a single-platform protocol. CYTOMETRY. PART B, CLINICAL CYTOMETRY 2003; 55:8-13. [PMID: 12949954 DOI: 10.1002/cyto.b.10050] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND CD4(+) T-lymphocyte enumeration is vital for monitoring disease progression in individuals positive for the human immunodeficiency virus (HIV), and as a result, there is a need to develop cost-effective protocols that provide accuracy, precision, and affordability. Recently, PanLeucoGating has been shown to fulfill these requirements; however, although comparable to state-of-the-art single-platform protocols (SP), there is still a requirement for an accurate total white cell count. To overcome this limitation, we recently developed a flow-rate based calibration method that enables the PanLeucoGating protocol to be used as a SP approach, and in this study show that this approach can be used for CD4(+) T-lymphocyte enumeration. METHODS A total of 113 HIV samples were analyzed using three protocols: (a) state-of-the art SP bead-based method (MultiSet; predicate protocol), (b) PanLeucoGating protocol used as a dual-platform (DP) approach, and (c) the newly developed flow rate-based SP approach. We demonstrate that flow rate calibration can be achieved easily and that the method is highly comparable to the state-of-the-art SP method. RESULTS A high correlation was observed between the predicate protocol and the SP PanLeucoGating approach over the whole range of CD4 counts tested (r(2) = 0.9928; bias 8 cells/microl), including the clinically relevant range (e.g., 0-200 CD4 cells/microl; bias 0 cells/microl). For batched samples, the cost of providing a CD4(+) T-lymphocyte count was reduced to approximately US $1. CONCLUSIONS The SP PanLeucoGating is a cost-effective approach to CD4(+) T-lymphocyte enumeration that maintains accuracy and precision.
Collapse
Affiliation(s)
- Ian Storie
- UK NEQAS for Leucocyte Immunophenotyping, Royal Hallamshire Hospital, Sheffield, United Kingdom
| | | | | | | | | | | | | |
Collapse
|
30
|
Janossy G, Jani IV, Bradley NJ, Bikoue A, Pitfield T, Glencross DK. Affordable CD4(+)-T-cell counting by flow cytometry: CD45 gating for volumetric analysis. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2002; 9:1085-94. [PMID: 12204964 PMCID: PMC120051 DOI: 10.1128/cdli.9.5.1085-1094.2002] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2002] [Accepted: 04/22/2002] [Indexed: 11/20/2022]
Abstract
The flow cytometers that are currently supported by industry provide accurate CD4(+)-T-cell counts for monitoring human immunodeficiency virus disease but remain unaffordable for routine service work under resource-poor conditions. We therefore combined volumetric flow cytometry (measuring absolute lymphocyte counts in unit volumes of blood) and simpler protocols with generic monoclonal antibodies (MAbs) to increase cost efficiency. Volumetric absolute counts were generated using CD45/CD4 and CD45/CD8 MAb combinations in two parallel tubes. The percentage values for the various subsets were also determined within the leukocyte and lymphocyte populations utilizing a fully automated protocol. The levels of agreement between the newly developed method and the present industry standards, including both volumetric and bead-based systems using a full MAb panel for subset analysis, were tested by Bland-Altman analyses. The limits of agreement for CD4 counts generated by the volumetric methods using either CD45/CD4 (in a single tube) or the full Trio MAb panel (in three tubes) on the CytoronAbsolute flow cytometer were between -29 and +46 cells/mm(3) with very little bias for CD4 counts (in favor of the Trio method: +8 CD4(+) lymphocytes/mm(3); 0.38% of lymphocytes). The limits of agreement for absolute CD4 counts yielded by the volumetric CD45/CD4 method and the bead-based method were between -118 and +98 cells/mm(3), again with a negligible bias (-10 CD4(+) lymphocytes/mm(3)). In the volumetric method using CD45/CD8, the strongly CD8(+) cells were gated and the levels of agreement with the full Trio showed a minor bias (in favor of the Trio; +40 CD8(+) cells/mm(3); 5.2% of lymphocytes) without a significant influence on CD4/CD8 ratios. One trained flow cytometrist was able to process 300 to 400 stained tubes per day. This workload extrapolates to a throughput of >30,000 samples per year if both CD45/CD4 and CD45/CD8 stainings are performed for each patient or a throughput of >60,000 samples if only CD45/CD4 counts are tested in a single tube. Thus, on the basis of the high efficiency and excellent agreement with the present industry standards, volumetric flow cytometers with automated gating protocols and autobiosamplers, complemented by generic CD45, CD4, and CD8 MAbs used in two-color immunofluorescence, represent the most suitable arrangements for large regional laboratories in resource-poor settings.
Collapse
Affiliation(s)
- George Janossy
- HIV Immunology, Department of Immunology and Molecular Pathology, Royal Free and University College Medical School, London, United Kingdom.
| | | | | | | | | | | |
Collapse
|