1
|
Cheong YH, Lisak G. Physically Tailoring Ion Fluxes by Introducing Foamlike Structures into Polymeric Membranes of Solid Contact Ion-Selective Electrodes. ACS Sens 2021; 6:3667-3676. [PMID: 34585917 DOI: 10.1021/acssensors.1c01413] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Transmembrane ion fluxes have earlier been identified as a source of potential instability in solid contact ion-selective electrodes (SC-ISEs). In this work, foamlike structures were intentionally introduced into a potassium-sensitive plasticized poly(vinyl chloride) ion-selective membrane (ISM) near the membrane|solid contact interface by controlling the temperature during membrane deposition. Foamlike structures in the ISM were shown to be effective at physically tailoring the transport of ions in the ion-selective membrane, greatly reducing the flux of interfering ions from the sample to the membrane|solid contact interface. The drifts during a conventional water layer test were hence able to be greatly mitigated, even with SC-ISEs incorporating a relatively hydrophilic poly(3,4-ethylenedioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS) solid contact. In solutions with a high background concentration of interfering ions, equilibrated ion-selective electrodes with foamlike membranes were able to reproduce their initial potentials within 0.6 mV uncertainty (n = 3) from 0 to 18 h. This was achieved despite sensor exposure to solutions exceeding the selectivity limit of the ISEs in 3 h intervals, allowing improvement of the potential reproducibility of the sensors. Since the introduction of foamlike structures into ISM is linked to temperature-controlled membrane deposition, it is envisaged that the method is generally applicable to all solid contact ion-selective electrodes that are based on polymeric membranes and require membrane deposition from the cocktail solution.
Collapse
Affiliation(s)
- Yi Heng Cheong
- College of Engineering, School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
- Nanyang Environment and Water Research Institute, Residues and Resource Reclamation Center, 1 Cleantech Loop, Cleantech, Singapore 637141, Singapore
- Robert Bosch (South East Asia) Pte Ltd., 11 Bishan Street 21, Singapore 573943, Singapore
| | - Grzegorz Lisak
- College of Engineering, School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
- Nanyang Environment and Water Research Institute, Residues and Resource Reclamation Center, 1 Cleantech Loop, Cleantech, Singapore 637141, Singapore
| |
Collapse
|
2
|
|
3
|
Egorov VV, Novakovskii AD, Zdrachek EA. An Interface Equilibria-Triggered Time-Dependent Diffusion Model of the Boundary Potential and Its Application for the Numerical Simulation of the Ion-Selective Electrode Response in Real Systems. Anal Chem 2017; 90:1309-1316. [DOI: 10.1021/acs.analchem.7b04134] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Vladimir V. Egorov
- Department
of Analytical Chemistry, Belarusian State University, Leningradskaya
Str., 14, 220030 Minsk, Belarus
| | - Andrei D. Novakovskii
- Department
of Analytical Chemistry, Belarusian State University, Leningradskaya
Str., 14, 220030 Minsk, Belarus
- Research Institute for Physical Chemical Problems of the Belarusian State University, Leningradskaya Str., 14, 220030 Minsk, Belarus
| | - Elena A. Zdrachek
- Research Institute for Physical Chemical Problems of the Belarusian State University, Leningradskaya Str., 14, 220030 Minsk, Belarus
- Department
of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet
30, CH-1211 Geneva, Switzerland
| |
Collapse
|
4
|
Mikhelson KN, Peshkova MA. Advances and trends in ionophore-based chemical sensors. RUSSIAN CHEMICAL REVIEWS 2015. [DOI: 10.1070/rcr4506] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
5
|
Zdrachek EA, Nazarov VA, Egorov VV. Generalized Diffusion Parameter: Main Factors of Influence and Application for Estimation of Selectivity Coefficients for Highly Selective Electrodes. ELECTROANAL 2015. [DOI: 10.1002/elan.201400584] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
6
|
Kabagambe B, Garada MB, Ishimatsu R, Amemiya S. Subnanomolar detection limit of stripping voltammetric Ca²⁺-selective electrode: effects of analyte charge and sample contamination. Anal Chem 2014; 86:7939-46. [PMID: 24992261 DOI: 10.1021/ac501951m] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Ultrasensitive ion-selective electrode measurements based on stripping voltammetry are an emerging sensor technology with low- and subnanomolar detection limits. Here, we report on stripping voltammetry of down to 0.1 nM Ca(2+) by using a thin-polymer-coated electrode and demonstrate the advantageous effects of the divalent charge on sensitivity. A simple theory predicts that the maximum concentration of an analyte ion preconcentrated in the thin membrane depends exponentially on the charge and that the current response based on exhaustive ion stripping from the thin membrane is proportional to the square of the charge. The theoretical predictions are quantitatively confirmed by using a thin ionophore-doped polymer membrane spin-coated on a conducting-polymer-modified electrode. The potentiostatic transfer of hydrophilic Ca(2+) from an aqueous sample into the hydrophobic double-polymer membrane is facilitated by an ionophore with high Ca(2+) affinity and selectivity. The resultant concentration of the Ca(2+)-ionophore complex in the ~1 μm-thick membrane can be at least 5 × 10(6) times higher than the aqueous Ca(2+) concentration. The stripping voltammetric current response to the divalent ion is enhanced to achieve a subnanomolar detection limit under the condition where a low-nanomolar detection limit is expected for a monovalent ion. Significantly, charge-dependent sensitivity is attractive for the ultrasensitive detection of multivalent ions with environmental and biomedical importance such as heavy metal ions and polyionic drugs. Importantly, this stripping voltammetric approach enables the absolute determination of subnanomolar Ca(2+) contamination in ultrapure water containing 10 mM supporting electrolytes, i.e., an 8 orders of magnitude higher background concentration.
Collapse
Affiliation(s)
- Benjamin Kabagambe
- Department of Chemistry, University of Pittsburgh , 219 Parkman Avenue, Pittsburgh, Pennsylvania 15260, United States
| | | | | | | |
Collapse
|
7
|
Gold nanoparticles solid contact for ion-selective electrodes of highly stable potential readings. Talanta 2011; 85:1986-9. [DOI: 10.1016/j.talanta.2011.07.049] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2011] [Revised: 07/07/2011] [Accepted: 07/09/2011] [Indexed: 11/17/2022]
|
8
|
Lindfors T, Höfler L, Jágerszki G, Gyurcsányi RE. Hyphenated FT-IR-Attenuated Total Reflection and Electrochemical Impedance Spectroscopy Technique to Study the Water Uptake and Potential Stability of Polymeric Solid-Contact Ion-Selective Electrodes. Anal Chem 2011; 83:4902-8. [DOI: 10.1021/ac200597b] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Tom Lindfors
- Laboratory of Analytical Chemistry, Process Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo, Finland
- Academy of Finland, Helsinki, Finland
| | - Lajos Höfler
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary
- Department of Chemistry, The University of Michigan, 930 N. University, Ann Arbor, Michigan 48109-1055, United States
| | - Gyula Jágerszki
- Research Group of Technical Analytical Chemistry of the Hungarian Academy of Sciences, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| | - Róbert E. Gyurcsányi
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary
- Research Group of Technical Analytical Chemistry of the Hungarian Academy of Sciences, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| |
Collapse
|
9
|
Peper S, Gonczy C. Potentiometric Response Characteristics of Membrane-BasedCs+-Selective Electrodes Containing Ionophore-Functionalized Polymeric Microspheres. INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY 2011. [DOI: 10.4061/2011/276896] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Cs+-selective solvent polymeric membrane-based ion-selective electrodes (ISEs) were developed by doping ethylene glycol-functionalized cross-linked polystyrene microspheres (P-EG) into a plasticized poly(vinyl chloride) (PVC) matrix containing sodium tetrakis-(3,5-bis(trifluoromethyl)phenyl) borate (TFPB) as the ion exchanger. A systematic study examining the effects of the membrane plasticizers bis(2-ethylhexyl) sebacate (DOS), 2-nitrophenyl octyl ether (NPOE), and 2-fluorophenyl nitrophenyl ether (FPNPE) on the potentiometric response and selectivity of the corresponding electrodes was performed. Under certain conditions, P-EG-based ion-selective electrodes (ISEs) containing TFPB and plasticized with NPOE exhibited a super-Nernstian response between1×10−3and1×10−4 M Cs+, a response characteristic not observed in analogous membranes plasticized with either DOS or FPNPE. Additionally, the performance of P-EG-based ISEs was compared to electrodes based on two mobile ionophores, a neutral lipophilic ethylene glycol derivative (ethylene glycol monooctadecyl ether (U-EG)) and a charged metallacarborane ionophore, sodium bis(dicarbollyl)cobaltate(III) (CC). In general, P-EG-based electrodes plasticized with FPNPE yielded the best performance, with a linear range from 10-1–10-5 M Cs+, a conventional lower detection limit of8.1×10−6 M Cs+, and a response slope of 57.7 mV/decade. The pH response of P-EG ISEs containing TFPB was evaluated for membranes plasticized with either NPOE or FPNPE. In both cases, the electrodes remained stable throughout the pH range 3–12, with only slight proton interference observed below pH 3.
Collapse
Affiliation(s)
- Shane Peper
- Chemistry Division, Los Alamos National Laboratory, Los Alamos, NM 87545, USA
- Radiochemical Analysis Group, Chemical & Physical Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99354, USA
| | - Chad Gonczy
- Chemistry Division, Los Alamos National Laboratory, Los Alamos, NM 87545, USA
| |
Collapse
|
10
|
Lindfors T, Szücs J, Sundfors F, Gyurcsányi RE. Polyaniline Nanoparticle-Based Solid-Contact Silicone Rubber Ion-Selective Electrodes for Ultratrace Measurements. Anal Chem 2010; 82:9425-32. [DOI: 10.1021/ac102099p] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Tom Lindfors
- Laboratory of Analytical Chemistry, Process Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo, Finland, Academy of Finland, Helsinki, Finland, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary, Research Group of Technical Analytical Chemistry of the Hungarian Academy of Sciences, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| | - Júlia Szücs
- Laboratory of Analytical Chemistry, Process Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo, Finland, Academy of Finland, Helsinki, Finland, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary, Research Group of Technical Analytical Chemistry of the Hungarian Academy of Sciences, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| | - Fredrik Sundfors
- Laboratory of Analytical Chemistry, Process Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo, Finland, Academy of Finland, Helsinki, Finland, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary, Research Group of Technical Analytical Chemistry of the Hungarian Academy of Sciences, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| | - Róbert E. Gyurcsányi
- Laboratory of Analytical Chemistry, Process Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo, Finland, Academy of Finland, Helsinki, Finland, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary, Research Group of Technical Analytical Chemistry of the Hungarian Academy of Sciences, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| |
Collapse
|
11
|
Vlasov YG, Ermolenko YE, Legin AV, Rudnitskaya AM, Kolodnikov VV. Chemical sensors and their systems. JOURNAL OF ANALYTICAL CHEMISTRY 2010. [DOI: 10.1134/s1061934810090029] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
12
|
Puri RK, Kumar V, Mahajan MP, Mahajan RK. Mercury(II) ion recognition by newly synthesized oxadiazaphosphepine based receptors: coated graphite and polymeric membrane electrodes. J INCL PHENOM MACRO 2010. [DOI: 10.1007/s10847-010-9837-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
13
|
Mikhelson KN. Ion-selective electrodes with sensitivity in strongly diluted solutions. JOURNAL OF ANALYTICAL CHEMISTRY 2010. [DOI: 10.1134/s1061934810020024] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
14
|
Zook JM, Bodor S, Gyurcsányi RE, Lindner E. Interpretation of chronopotentiometric transients of ion-selective membranes with two transition times. J Electroanal Chem (Lausanne) 2010; 638:254-261. [PMID: 20161602 DOI: 10.1016/j.jelechem.2009.11.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Passing currents through ion-selective membranes has contributed to the development of a variety of novel methods. In this work, chronopotentiometric (CP) transients with two transition times (breakpoints) are presented for the first time, with the theoretical interpretation of such voltage transients. The validity of our theory has been confirmed in experiments utilizing ETH 5294 chromoionophore-based pH sensitive membranes with and without lipophilic background electrolyte and ETH 5234 ionophore-based calcium selective membranes in which the ionophore forms 3:1 complexes with Ca(2+) ions. The conditions under which two breakpoints can be identified in the chronopotentiometric voltage transients are discussed.Spectroelectrochemical microscopy (SpECM) is used to show that the two breakpoints in the CP curves emerge approximately when the free ionophore and ion-ionophore complex concentrations approach zero at the opposite membrane-solution interfaces. The two breakpoint times can be utilized to follow simultaneously the concentration changes of the free ionophore, the ion-ionophore complex, and the mobile anionic sites in cation-selective membranes. In membranes with known composition, the time instances where breakpoints occur can be used to estimate the free ionophore and the ion-ionophore complex diffusion coefficients.
Collapse
Affiliation(s)
- Justin M Zook
- Department of Biomedical Engineering, The University of Memphis, Memphis, TN 38152, USA
| | | | | | | |
Collapse
|
15
|
Jágerszki G, Grün A, Bitter I, Tóth K, Gyurcsányi RE. Ionophore-gold nanoparticle conjugates for Ag(+)-selective sensors with nanomolar detection limit. Chem Commun (Camb) 2009; 46:607-9. [PMID: 20062877 DOI: 10.1039/b914430g] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We report on the synthesis and trace analytical application of ionophore-gold nanoparticle conjugates as a basis of a new concept in confining ionophores to ion-selective membranes using inert nanoparticle carriers.
Collapse
Affiliation(s)
- Gyula Jágerszki
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, H-1111 Budapest, Hungary
| | | | | | | | | |
Collapse
|
16
|
Sundfors F, Lindfors T, Höfler L, Bereczki R, Gyurcsányi RE. FTIR-ATR Study of Water Uptake and Diffusion through Ion-Selective Membranes Based on Poly(acrylates) and Silicone Rubber. Anal Chem 2009; 81:5925-34. [DOI: 10.1021/ac900727w] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Fredrik Sundfors
- Process Chemistry Centre, Laboratory of Analytical Chemistry, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo/Turku, Finland, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary, and Research Group of Technical Analytical Chemistry, Hungarian Academy of Sciences, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| | - Tom Lindfors
- Process Chemistry Centre, Laboratory of Analytical Chemistry, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo/Turku, Finland, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary, and Research Group of Technical Analytical Chemistry, Hungarian Academy of Sciences, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| | - Lajos Höfler
- Process Chemistry Centre, Laboratory of Analytical Chemistry, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo/Turku, Finland, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary, and Research Group of Technical Analytical Chemistry, Hungarian Academy of Sciences, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| | - Róbert Bereczki
- Process Chemistry Centre, Laboratory of Analytical Chemistry, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo/Turku, Finland, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary, and Research Group of Technical Analytical Chemistry, Hungarian Academy of Sciences, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| | - Róbert E. Gyurcsányi
- Process Chemistry Centre, Laboratory of Analytical Chemistry, Åbo Akademi University, Biskopsgatan 8, FI-20500 Åbo/Turku, Finland, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary, and Research Group of Technical Analytical Chemistry, Hungarian Academy of Sciences, Budapest University of Technology and Economics, H-1111 Budapest, Szt. Gellért tér 4, Hungary
| |
Collapse
|
17
|
Peshkova MA, Sokalski T, Mikhelson KN, Lewenstam A. Obtaining Nernstian Response of a Ca2+-Selective Electrode in a Broad Concentration Range by Tuned Galvanostatic Polarization. Anal Chem 2008; 80:9181-7. [DOI: 10.1021/ac8013143] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Maria A. Peshkova
- Chemical Faculty, c/o St. Petersburg State University, Universitetskij Pr. 26, 198504 St. Petersburg, Russia, and Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology “ProSens” and Laboratory of Analytical Chemistry, Åbo Akademi University, Biskopsgatan 8, FIN-20500 Åbo/Turku, Finland
| | - Tomasz Sokalski
- Chemical Faculty, c/o St. Petersburg State University, Universitetskij Pr. 26, 198504 St. Petersburg, Russia, and Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology “ProSens” and Laboratory of Analytical Chemistry, Åbo Akademi University, Biskopsgatan 8, FIN-20500 Åbo/Turku, Finland
| | - Konstantin N. Mikhelson
- Chemical Faculty, c/o St. Petersburg State University, Universitetskij Pr. 26, 198504 St. Petersburg, Russia, and Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology “ProSens” and Laboratory of Analytical Chemistry, Åbo Akademi University, Biskopsgatan 8, FIN-20500 Åbo/Turku, Finland
| | - Andrzej Lewenstam
- Chemical Faculty, c/o St. Petersburg State University, Universitetskij Pr. 26, 198504 St. Petersburg, Russia, and Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology “ProSens” and Laboratory of Analytical Chemistry, Åbo Akademi University, Biskopsgatan 8, FIN-20500 Åbo/Turku, Finland
| |
Collapse
|
18
|
Lindner E, Gyurcsányi RE. Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes. J Solid State Electrochem 2008. [DOI: 10.1007/s10008-008-0608-1] [Citation(s) in RCA: 243] [Impact Index Per Article: 15.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
19
|
Affiliation(s)
- Johan Bobacka
- Åbo Akademi University, Process Chemistry Centre, c/o Laboratory of Analytical Chemistry, Biskopsgatan 8, FI-20500 Turku-Åbo, Finland; Faculty of Material Science and Ceramics, AGH-University of Science and Technology, Al. Mickiewicza 30, PL-30059 Cracow, Poland; and Åbo Akademi University, Process Chemistry Centre, c/o Center for Process Analytical Chemistry and Sensor Technology (ProSens), Biskopsgatan 8, FI-20500 Turku-Åbo, Finland
| | - Ari Ivaska
- Åbo Akademi University, Process Chemistry Centre, c/o Laboratory of Analytical Chemistry, Biskopsgatan 8, FI-20500 Turku-Åbo, Finland; Faculty of Material Science and Ceramics, AGH-University of Science and Technology, Al. Mickiewicza 30, PL-30059 Cracow, Poland; and Åbo Akademi University, Process Chemistry Centre, c/o Center for Process Analytical Chemistry and Sensor Technology (ProSens), Biskopsgatan 8, FI-20500 Turku-Åbo, Finland
| | - Andrzej Lewenstam
- Åbo Akademi University, Process Chemistry Centre, c/o Laboratory of Analytical Chemistry, Biskopsgatan 8, FI-20500 Turku-Åbo, Finland; Faculty of Material Science and Ceramics, AGH-University of Science and Technology, Al. Mickiewicza 30, PL-30059 Cracow, Poland; and Åbo Akademi University, Process Chemistry Centre, c/o Center for Process Analytical Chemistry and Sensor Technology (ProSens), Biskopsgatan 8, FI-20500 Turku-Åbo, Finland
| |
Collapse
|
20
|
Bodor S, Zook JM, Lindner E, Tóth K, Gyurcsányi RE. Electrochemical methods for the determination of the diffusion coefficient of ionophores and ionophore–ion complexes in plasticized PVC membranes. Analyst 2008; 133:635-42. [DOI: 10.1039/b718110h] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
21
|
Konopka A, Sokalski T, Lewenstam A, Maj-Żurawska M. The Influence of the Conditioning Procedure on Potentiometric Characteristics of Solid Contact Calcium-Selective Electrodes in Nanomolar Concentration Solutions. ELECTROANAL 2006. [DOI: 10.1002/elan.200603652] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
22
|
Sundfors F, Bereczki R, Bobacka J, Tóth K, Ivaska A, Gyurcsányi R. Microcavity Based Solid-Contact Ion-Selective Microelectrodes. ELECTROANAL 2006. [DOI: 10.1002/elan.200603541] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
23
|
Móczár I, Gyurcsányi R, Huszthy P, Jágerszki G, Tóth K, Lindner E. Synthesis and Characterization of a Novel, Colored Lipophilic Additive for Spectral Imaging the Transport in Ionophore Based Ion-Selective Membranes. ELECTROANAL 2006. [DOI: 10.1002/elan.200603551] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
24
|
Szigeti Z, Vigassy T, Bakker E, Pretsch E. Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion-Selective Electrodes. ELECTROANAL 2006; 18:1254-1265. [PMID: 20336172 PMCID: PMC2844646 DOI: 10.1002/elan.200603539] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2006] [Accepted: 04/03/2006] [Indexed: 11/10/2022]
Abstract
More than ten different approaches for improving the lower detection limit of polymeric membrane ion-selective electrodes have been suggested during the recent years. In this contribution, their principles are briefly summarized with a focus to their general practical applicability. The methods that are the most rugged and the easiest to implement in a routine laboratory will be highlighted.
Collapse
Affiliation(s)
- Zsófia Szigeti
- Laboratorium für Organische Chemie, ETH-Hönggerberg, HCI E313, CH-8093 Zürich, Switzerland
| | - Tamás Vigassy
- Laboratorium für Organische Chemie, ETH-Hönggerberg, HCI E313, CH-8093 Zürich, Switzerland
| | - Eric Bakker
- Department of Chemistry, 560 Oval Drive, Purdue University, West Lafayette, IN 47907, USA
| | - Ernö Pretsch
- Laboratorium für Organische Chemie, ETH-Hönggerberg, HCI E313, CH-8093 Zürich, Switzerland
| |
Collapse
|
25
|
Sutter J, Pretsch E. Response Behavior of Poly(vinyl chloride)- and Polyurethane-Based Ca2+-Selective Membrane Electrodes with Polypyrrole- and Poly(3-octylthiophene)-Mediated Internal Solid Contact. ELECTROANAL 2006. [DOI: 10.1002/elan.200503373] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
26
|
Gyurcsányi RE, Lindner E. Multispectral imaging of ion transport in neutral carrier-based cation-selective membranes. Cytometry A 2006; 69:792-804. [PMID: 16969802 DOI: 10.1002/cyto.a.20276] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND High-resolution spectroscopic imaging of the cross section of ion-selective membranes during real-time electrochemical measurements is termed spectroelectrochemical microscopy (SpECM). SpECM is aimed for optimizing the experimental conditions in mass transport controlled ion-selective electrode (ISE) membranes for improved detection limit. METHODS The SpECM measurements are performed in a thin layer electrochemical cell. The key element of the cell is a membrane strip spacer ring assembly which forms a two compartment electrochemical cell. The cell is placed onto the stage of a microscope and the membrane strip is positioned in the center of the field of view. A slice of the image is focused onto the entrance slit of the imaging spectrometer. RESULTS SpECM has been used for the determination of the diffusion coefficients of different membrane ingredients and for the quantitative assessment of the charged site concentrations in ISE membranes and membrane plasticizers. In addition, changes in the concentration profiles of the ionophore (free and complexed) and charged mobile sites inside the ISE membranes are documented upon the application of large external voltages. CONCLUSIONS This account demonstrates the power and advantages of SpECM, a multispectral imaging method for investigations of mass transport processes in ISE membranes during electrochemical measurements.
Collapse
Affiliation(s)
- Robert E Gyurcsányi
- Department of General and Analytical Chemistry, Budapest University of Technology and Economics, Szent Gellért tér 4, 1111 Budapest, Hungary
| | | |
Collapse
|
27
|
Abstract
This review summarizes recent progress in the development and application of potentiometric sensors with limits of detection (LODs) in the range 10(-8)-10(-11) M. These LODs relate to total sample concentrations and are defined according to a definition unique to potentiometric sensors. LODs calculated according to traditional protocols (three times the standard deviation of the noise) yield values that are two orders of magnitude lower. We are targeting this article at analytical chemists who are non-specialists in the development of such sensors so that this technology may be adopted by a growing number of research groups to solve real-world analytical problems.We discuss the unique response features of potentiometric sensors and compare them to other analytical techniques, emphasizing that the choice of the method must depend on the problem of interest. We discuss recent directions in sensor design and development and present a list of 23 sensors with low LODs, with references. We give recent examples where potentiometric sensors have been used to solve trace-level analytical problems, including the speciation of lead and copper ions in drinking water, the measurement of free copper in sea water, and the uptake of cadmium ions by plant roots as a function of their speciation.
Collapse
Affiliation(s)
- Eric Bakker
- Department of Chemistry, Auburn University, AL 36849, USA
| | - Ernö Pretsch
- Laboratorium für Organische Chemie, ETH Hönggerberg, CH-8093 Zürich, Switzerland
| |
Collapse
|
28
|
Sutter J, Radu A, Peper S, Bakker E, Pretsch E. Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2004.07.016] [Citation(s) in RCA: 179] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
29
|
Affiliation(s)
- Eric Bakker
- Department of Chemistry, Auburn University, Auburn, Alabama 36849, USA
| |
Collapse
|
30
|
Püntener M, Vigassy T, Baier E, Ceresa A, Pretsch E. Improving the lower detection limit of potentiometric sensors by covalently binding the ionophore to a polymer backbone. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2003.10.030] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|