1
|
Ashrafi AM, Selcuk O, Mukherjee A, Unal DN, Kurbanoglu S, Uslu B, Jurica J, Pekarkova J, Richtera L, Adam V. Rapid determination of uracil in biological fluids at mercury thin film electrode for early detection of potential 5-fluorouracil toxicity due to dihydropyrimidine dehydrogenase deficiency. Biosens Bioelectron 2024; 262:116545. [PMID: 38971040 DOI: 10.1016/j.bios.2024.116545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 06/24/2024] [Accepted: 06/27/2024] [Indexed: 07/08/2024]
Abstract
Determination of plasma uracil was reported as a method for evaluation of Dihydropyrimidine dehydrogenase (DPD) activity that is highly demanded to ensure the safe administration of 5-fluorouracil (5-FU)-based therapies to cancer patients. This work reports the development of a simple electroanalytical method based on adsorptive stripping square wave voltammetry (AdSWV) at mercury film-coated glassy carbon electrode (MF/GCE) for the highly sensitive determination of uracil in biological fluids that can be used for diagnosis of decreased DPD activity. Due to the formation of the HgII-Uracil complex at the electrode surface, the accuracy of the measurement was not affected by the complicated matrices in biological fluids including human serum, plasma, and urine. The high sensitivity of the developed method results in a low limit of detection (≈1.3 nM) in human plasma samples, falling below the practical cut-off level of 15 ng mL-1 (≈0.14 μM). This threshold concentration is crucial for predicting 5-FU toxicity, as reported in buffer, and ≤1.15% in biological samples), and accuracy (recovery percentage close to 100%).
Collapse
Affiliation(s)
- Amir M Ashrafi
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Institute of Photonics and Electronics, Czech Academy of Sciences, Prague, Czech Republic.
| | - Ozge Selcuk
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey; Mersin University, Faculty of Pharmacy, Department of Analytical Chemistry, 33169, Mersin, Turkey.
| | - Atripan Mukherjee
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; ELI Beamlines Facility, The Extreme Light Infrastructure ERIC, Za Radnicí 835, 252 41, Dolní Břežany, Czech Republic.
| | - Didem Nur Unal
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey; Ankara University, The Graduate School of Health Sciences, 06110, Ankara, Turkey.
| | - Sevinc Kurbanoglu
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey.
| | - Bengi Uslu
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey.
| | - Jan Jurica
- Department of Pharmacology, Faculty of Medicine, Masaryk University, Brno, Czech Republic; Department of Pharmacology and Toxicology, Faculty of Pharmacy, Masaryk University, Brno, Czech Republic; Masaryk Memorial Cancer Institute, Brno, Czech Republic.
| | - Jana Pekarkova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic.
| | - Lukas Richtera
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic.
| | - Vojtech Adam
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic.
| |
Collapse
|
2
|
Souza KA, Nunes AM, Pimentel DM, Verly RM, Gil ES, Malagutti AR, dos Santos WT. Altered electrochemistry of amiloride drug on boron-doped diamond electrode: Rapid and selective detection in urine by square-wave cathodic stripping voltammetry for application in doping control. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.137891] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
5
|
Bukkitgar SD, Shetti NP. Electrochemical Sensor for the Determination of Anticancer Drug 5- Fluorouracil at Glucose Modified Electrode. ChemistrySelect 2016. [DOI: 10.1002/slct.201600197] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- Shikandar D. Bukkitgar
- Department of Chemistry; K.L.E. Institution of Technology; Opposite to airport, Gokul, Hubballi- 580030 Karnataka India
| | - Nagaraj P. Shetti
- Department of Chemistry; K.L.E. Institution of Technology; Opposite to airport, Gokul, Hubballi- 580030 Karnataka India
- Affiliated to Visvesvaraya Technological University, Belgavi; Karnataka India
| |
Collapse
|
8
|
Mirceski V, Laborda E, Guziejewski D, Compton RG. New approach to electrode kinetic measurements in square-wave voltammetry: amplitude-based quasireversible maximum. Anal Chem 2013; 85:5586-94. [PMID: 23642036 DOI: 10.1021/ac4008573] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The influence of the potential pulse height of square-wave voltammetry (SWV) (i.e., the SW amplitude) is studied for a variety of quasireversible electrode mechanisms, including a simple solution-phase electrode reaction at a planar or spherical electrode, a solution phase electrode reaction coupled with a reversible follow-up chemical reaction, and a diffusionless surface confined electrode reaction. The electrode kinetics of all the electrode mechanisms depends critically on the SW amplitude, and the quasireversible kinetic region is a function of both frequency-related electrode kinetic parameters and the SW amplitude. Thus, a novel methodology for electrode kinetics measurements is proposed by altering the SW amplitude only, at a fixed frequency of the SW potential modulation, that is, at a constant scan rate of the voltammetric experiment. Electrode kinetic measurements at a constant SW frequency are of exceptional importance especially when complex electrode mechanisms are studied, which depend on several frequency-related kinetic parameters. The electrode kinetic measurements are based on a novel feature termed the "amplitude-based quasireversible maximum", manifested as a parabolic dependence of the amplitude-normalized net SW peak current versus the SW amplitude. The position of the amplitude-based quasireversible maximum depends on the standard rate constant of the electrode reaction, enabling estimation of this important kinetic parameter in a simple and fast procedure. The novel quasireversible maximum is attributed to all studied electrode mechanisms, implying that it is a general feature of most electrode mechanisms under conditions of SWV.
Collapse
Affiliation(s)
- Valentin Mirceski
- Institute of Chemistry, Faculty of Natural Sciences and Mathematics, Ss Cyril and Methodius University, P.O. Box 162, 1000 Skopje, Republic of Macedonia.
| | | | | | | |
Collapse
|