1
|
Abstract
Interpretation of impedance spectroscopy data requires both a description of the chemistry and physics that govern the system and an assessment of the error structure of the measurement. The approach presented here includes use of graphical methods to guide model development, use of a measurement model analysis to assess the presence of stochastic and bias errors, and a systematic development of interpretation models in terms of the proposed reaction mechanism and physical description. Application to corrosion, batteries, and biological systems is discussed, and emerging trends in interpretation and implementation of impedance spectroscopy are presented.
Collapse
Affiliation(s)
- Vincent Vivier
- Sorbonne Université, CNRS, Laboratoire de Réactivité de Surface, 4 place Jussieu, Paris 75005 Cedex 05, France
| | - Mark E Orazem
- Department of Chemical Engineering, University of Florida, Gainesville, Florida 32611, United States
| |
Collapse
|
2
|
Revolution in Flexible Wearable Electronics for Temperature and Pressure Monitoring—A Review. ELECTRONICS 2022. [DOI: 10.3390/electronics11050716] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
In the last few decades, technology innovation has had a huge influence on our lives and well-being. Various factors of observing our physiological characteristics are taken into account. Wearable sensing tools are one of the most imperative sectors that are now trending and are expected to grow significantly in the coming days. Externally utilized tools connected to any human to assess physiological characteristics of interest are known as wearable sensors. Wearable sensors range in size from tiny to large tools that are physically affixed to the user and operate on wired or wireless terms. With increasing technological capabilities and a greater grasp of current research procedures, the usage of wearable sensors has a brighter future. In this review paper, the recent developments of two important types of wearable electronics apparatuses have been discussed for temperature and pressure sensing (Psensing) applications. Temperature sensing (Tsensing) is one of the most important physiological factors for determining human body temperature, with a focus on patients with long-term chronic conditions, normally healthy, unconscious, and injured patients receiving surgical treatment, as well as the health of medical personnel. Flexile Psensing devices are classified into three categories established on their transduction mechanisms: piezoresistive, capacitive, and piezoelectric. Many efforts have been made to enhance the characteristics of the flexible Psensing devices established on these mechanisms.
Collapse
|
3
|
Zafar H, Channa A, Jeoti V, Stojanović GM. Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring. SENSORS (BASEL, SWITZERLAND) 2022; 22:638. [PMID: 35062598 PMCID: PMC8781973 DOI: 10.3390/s22020638] [Citation(s) in RCA: 61] [Impact Index Per Article: 30.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/16/2021] [Accepted: 12/31/2021] [Indexed: 02/07/2023]
Abstract
The incidence of diabetes is increasing at an alarming rate, and regular glucose monitoring is critical in order to manage diabetes. Currently, glucose in the body is measured by an invasive method of blood sugar testing. Blood glucose (BG) monitoring devices measure the amount of sugar in a small sample of blood, usually drawn from pricking the fingertip, and placed on a disposable test strip. Therefore, there is a need for non-invasive continuous glucose monitoring, which is possible using a sweat sensor-based approach. As sweat sensors have garnered much interest in recent years, this study attempts to summarize recent developments in non-invasive continuous glucose monitoring using sweat sensors based on different approaches with an emphasis on the devices that can potentially be integrated into a wearable platform. Numerous research entities have been developing wearable sensors for continuous blood glucose monitoring, however, there are no commercially viable, non-invasive glucose monitors on the market at the moment. This review article provides the state-of-the-art in sweat glucose monitoring, particularly keeping in sight the prospect of its commercialization. The challenges relating to sweat collection, sweat sample degradation, person to person sweat amount variation, various detection methods, and their glucose detection sensitivity, and also the commercial viability are thoroughly covered.
Collapse
Affiliation(s)
- Hima Zafar
- Faculty of Technical Sciences, University of Novi Sad, T. Dositeja Obradovića 6, 21000 Novi Sad, Serbia; (V.J.); (G.M.S.)
| | - Asma Channa
- Computer Science Department, University Politehnica of Bucharest, 060042 Bucharest, Romania;
- DIIES Department, Mediterranea University of Reggio Calabria, 89100 Reggio Calabria, Italy
| | - Varun Jeoti
- Faculty of Technical Sciences, University of Novi Sad, T. Dositeja Obradovića 6, 21000 Novi Sad, Serbia; (V.J.); (G.M.S.)
| | - Goran M. Stojanović
- Faculty of Technical Sciences, University of Novi Sad, T. Dositeja Obradovića 6, 21000 Novi Sad, Serbia; (V.J.); (G.M.S.)
| |
Collapse
|
4
|
Abe Y, Nishizawa M. Electrical aspects of skin as a pathway to engineering skin devices. APL Bioeng 2021; 5:041509. [PMID: 34849444 PMCID: PMC8604566 DOI: 10.1063/5.0064529] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 09/27/2021] [Indexed: 02/07/2023] Open
Abstract
Skin is one of the indispensable organs for life. The epidermis at the outermost surface provides a permeability barrier to infectious agents, chemicals, and excessive loss of water, while the dermis and subcutaneous tissue mechanically support the structure of the skin and appendages, including hairs and secretory glands. The integrity of the integumentary system is a key for general health, and many techniques have been developed to measure and control this protective function. In contrast, the effective skin barrier is the major obstacle for transdermal delivery and detection. Changes in the electrical properties of skin, such as impedance and ionic activity, is a practical indicator that reflects the structures and functions of the skin. For example, the impedance that reflects the hydration of the skin is measured for quantitative assessment in skincare, and the current generated across a wound is used for the evaluation and control of wound healing. Furthermore, the electrically charged structure of the skin enables transdermal drug delivery and chemical extraction. This paper provides an overview of the electrical aspects of the skin and summarizes current advances in the development of devices based on these features.
Collapse
Affiliation(s)
- Yuina Abe
- Department of Finemechanics, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
| | - Matsuhiko Nishizawa
- Department of Finemechanics, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
| |
Collapse
|
5
|
Van Hoovels K, Xuan X, Cuartero M, Gijssel M, Swarén M, Crespo GA. Can Wearable Sweat Lactate Sensors Contribute to Sports Physiology? ACS Sens 2021; 6:3496-3508. [PMID: 34549938 PMCID: PMC8546758 DOI: 10.1021/acssensors.1c01403] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
![]()
The rise of wearable
sensors to measure lactate content in human
sweat during sports activities has attracted the attention of physiologists
given the potential of these “analytical tools” to provide
real-time information. Beyond the assessment of the sensing technology per se, which, in fact, has not rigorously been validated
yet in controlled conditions, there are many open questions about
the true usefulness of such wearable sensors in real scenarios. On
the one hand, the evidence for the origin of sweat lactate (e.g.,
via the sweat gland, derivation from blood, or other alternative mechanisms),
its high concentration (1–25 mM or even higher) compared to
levels in the blood, and the possible correlation between different
biofluids (particularly blood) is rather contradictory and generates
vivid debate in the field. On the other hand, it is important to point
out that accurate detection of sweat lactate is highly dependent on
the procedure used to collect and/or reach the fluid, and this can
likely explain the large discrepancies reported in the literature.
In brief, this paper provides our vision of the current state of the
field and a thoughtful evaluation of the possible reasons for present
controversies, together with an analysis of the impact of wearable
sweat lactate sensors in the physiological context. Finally, although
there is not yet overwhelming scientific evidence to provide an unequivocal
answer to whether wearable sweat lactate sensors can contribute to
sports physiology, we still understand the importance to bring this
challenging question up-front to create awareness and guidance in
the development, validation, and implementation of wearable sensors.
Collapse
Affiliation(s)
- Kevin Van Hoovels
- Kinetic Analysis, Sint Janssingel 92, 5211 DA ’s-Hertogenbosch, The Netherlands
- Jheronimus Academy of Data Science, Sint Janssingel 92, 5211 DA ’s-Hertogenbosch, The Netherlands
| | - Xing Xuan
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| | - Maria Cuartero
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| | - Maarten Gijssel
- Kinetic Analysis, Sint Janssingel 92, 5211 DA ’s-Hertogenbosch, The Netherlands
- Jheronimus Academy of Data Science, Sint Janssingel 92, 5211 DA ’s-Hertogenbosch, The Netherlands
| | - Mikael Swarén
- Swedish Unit of Metrology in Sports, Institution of Health and Welfare, Dalarna University, SE-791 88 Falun, Sweden
| | - Gaston A. Crespo
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| |
Collapse
|
6
|
Jankovskaja S, Labrousse A, Prévaud L, Holmqvist B, Brinte A, Engblom J, Rezeli M, Marko-Varga G, Ruzgas T. Visualisation of H 2O 2 penetration through skin indicates importance to develop pathway-specific epidermal sensing. Mikrochim Acta 2020; 187:656. [PMID: 33188446 PMCID: PMC7666278 DOI: 10.1007/s00604-020-04633-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Accepted: 11/01/2020] [Indexed: 01/07/2023]
Abstract
Elevated amounts of reactive oxygen species (ROS) including hydrogen peroxide (H2O2) are observed in the epidermis in different skin disorders. Thus, epidermal sensing of H2O2 should be useful to monitor the progression of skin pathologies. We have evaluated epidermal sensing of H2O2 in vitro, by visualising H2O2 permeation through the skin. Skin membranes were mounted in Franz cells, and a suspension of Prussian white microparticles was deposited on the stratum corneum face of the skin. Upon H2O2 permeation, Prussian white was oxidised to Prussian blue, resulting in a pattern of blue dots. Comparison of skin surface images with the dot patterns revealed that about 74% of the blue dots were associated with hair shafts. The degree of the Prussian white to Prussian blue conversion strongly correlated with the reciprocal resistance of the skin membranes. Together, the results demonstrate that hair follicles are the major pathways of H2O2 transdermal penetration. The study recommends that the development of H2O2 monitoring on skin should aim for pathway-specific epidermal sensing, allowing micrometre resolution to detect and quantify this ROS biomarker at hair follicles.Graphical abstract.
Collapse
Affiliation(s)
- Skaidre Jankovskaja
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 205 06, Malmö, Sweden
- Biofilms - Research Center for Biointerfaces, Malmö University, 205 06, Malmö, Sweden
| | - Anaïs Labrousse
- Department of Biological Engineering, Clermont Auvergne University, 63100, Aubiere, France
| | - Léa Prévaud
- Faculty of Sciences, University of Montpellier, 34085, Montpellier, France
| | - Bo Holmqvist
- ImaGene-iT, Medicon Village, 223 81, Lund, Sweden
| | | | - Johan Engblom
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 205 06, Malmö, Sweden
- Biofilms - Research Center for Biointerfaces, Malmö University, 205 06, Malmö, Sweden
| | - Melinda Rezeli
- Clinical Protein Science & Imaging, Biomedical Centre, Department of Biomedical Engineering, Lund University, BMC D13, 221 84, Lund, Sweden
| | - György Marko-Varga
- Clinical Protein Science & Imaging, Biomedical Centre, Department of Biomedical Engineering, Lund University, BMC D13, 221 84, Lund, Sweden
| | - Tautgirdas Ruzgas
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 205 06, Malmö, Sweden.
- Biofilms - Research Center for Biointerfaces, Malmö University, 205 06, Malmö, Sweden.
| |
Collapse
|
7
|
Matsukawa R, Miyamoto A, Yokota T, Someya T. Skin Impedance Measurements with Nanomesh Electrodes for Monitoring Skin Hydration. Adv Healthc Mater 2020; 9:e2001322. [PMID: 33084247 DOI: 10.1002/adhm.202001322] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 09/19/2020] [Indexed: 12/22/2022]
Abstract
The importance of continuous monitoring of skin hydration in daily life, to aid in the diagnosis of skin diseases, is rising. Electrodes that can be worn directly on the skin are attracting attention as an effective means. However, they should not inhibit natural water evaporation from the skin and should not cause inflammation or irritation even if they are attached to the body for long periods of time. In this study, nanomesh electrodes that have previously been reported to exhibit high biocompatibility are also found to exhibit high water vapor permeability, resulting in properties that prevent skin dampness. Furthermore, the skin impedance measured using nanomesh electrodes is found to correlate with the hydration level of skin measured using existing medical equipment. This study provides a new approach to measure skin hydration in conditions close to bare skin.
Collapse
Affiliation(s)
- Ryotaro Matsukawa
- Department of Electrical Engineering and Information Systems School of Engineering The University of Tokyo 7‐3‐1 Hongo, Bunkyo‐ku Tokyo 113–8656 Japan
| | - Akihito Miyamoto
- Department of Electrical Engineering and Information Systems School of Engineering The University of Tokyo 7‐3‐1 Hongo, Bunkyo‐ku Tokyo 113–8656 Japan
| | - Tomoyuki Yokota
- Department of Electrical Engineering and Information Systems School of Engineering The University of Tokyo 7‐3‐1 Hongo, Bunkyo‐ku Tokyo 113–8656 Japan
| | - Takao Someya
- Department of Electrical Engineering and Information Systems School of Engineering The University of Tokyo 7‐3‐1 Hongo, Bunkyo‐ku Tokyo 113–8656 Japan
| |
Collapse
|
8
|
Yang X, Cheng H. Recent Developments of Flexible and Stretchable Electrochemical Biosensors. MICROMACHINES 2020; 11:E243. [PMID: 32111023 PMCID: PMC7143805 DOI: 10.3390/mi11030243] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 02/20/2020] [Accepted: 02/24/2020] [Indexed: 12/14/2022]
Abstract
The skyrocketing popularity of health monitoring has spurred increasing interest in wearable electrochemical biosensors. Compared with the traditionally rigid and bulky electrochemical biosensors, flexible and stretchable devices render a unique capability to conform to the complex, hierarchically textured surfaces of the human body. With a recognition element (e.g., enzymes, antibodies, nucleic acids, ions) to selectively react with the target analyte, wearable electrochemical biosensors can convert the types and concentrations of chemical changes in the body into electrical signals for easy readout. Initial exploration of wearable electrochemical biosensors integrates electrodes on textile and flexible thin-film substrate materials. A stretchable property is needed for the thin-film device to form an intimate contact with the textured skin surface and to deform with various natural skin motions. Thus, stretchable materials and structures have been exploited to ensure the effective function of a wearable electrochemical biosensor. In this mini-review, we summarize the recent development of flexible and stretchable electrochemical biosensors, including their principles, representative application scenarios (e.g., saliva, tear, sweat, and interstitial fluid), and materials and structures. While great strides have been made in the wearable electrochemical biosensors, challenges still exist, which represents a small fraction of opportunities for the future development of this burgeoning field.
Collapse
Affiliation(s)
- Xudong Yang
- Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing 400044, China;
- Department of Automotive Engineering, Beihang University, Beijing 100191, China
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
| | - Huanyu Cheng
- Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing 400044, China;
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
9
|
Piro B, Mattana G, Noël V. Recent Advances in Skin Chemical Sensors. SENSORS 2019; 19:s19204376. [PMID: 31658706 PMCID: PMC6832670 DOI: 10.3390/s19204376] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 09/26/2019] [Accepted: 10/08/2019] [Indexed: 01/06/2023]
Abstract
This review summarizes the latest developments in the field of skin chemical sensors, in particular wearable ones. Five major applications are covered in the present work: (i) sweat analysis, (ii) skin hydration, (iii) skin wounds, (iv) perspiration of volatile organic compounds, and (v) general skin conditions. For each application, the detection of the most relevant analytes is described in terms of transduction principles and sensor performances. Special attention is paid to the biological fluid collection and storage and devices are also analyzed in terms of reusability and lifetime. This review highlights the existing gaps between current performances and those needed to promote effective commercialization of sensors; future developments are also proposed.
Collapse
Affiliation(s)
- Benoît Piro
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 rue J-A de Baïf, F-75013 Paris, France.
| | - Giorgio Mattana
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 rue J-A de Baïf, F-75013 Paris, France.
| | - Vincent Noël
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 rue J-A de Baïf, F-75013 Paris, France.
| |
Collapse
|
10
|
Eldamak AR, Fear EC. Conformal and Disposable Antenna-Based Sensor for Non-Invasive Sweat Monitoring. SENSORS 2018; 18:s18124088. [PMID: 30469510 PMCID: PMC6308724 DOI: 10.3390/s18124088] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Revised: 11/17/2018] [Accepted: 11/20/2018] [Indexed: 11/16/2022]
Abstract
This paper presents a feasibility study for a non-wearable, conformal, low cost, and disposable antenna-based sensor for non-invasive hydration monitoring using sweat. It is composed of a patch antenna implemented on a cellulose filter paper substrate and operating in the range 2–4 GHz. The paper substrate can absorb liquids, such as sweat on the skin, through two slots incorporated within the antenna structure. Thus, the substrate dielectric properties are altered according to the properties of the absorbed liquid. Changes in reflection-based measurements are used to analyze salt solutions and artificial sweat, specifically the amount of sampled solution and the sodium chloride (NaCl) concentration. Using the shift in resonant frequency and magnitude of the reflection coefficient, NaCl concentrations in the range of 8.5–200 mmol/L, representing different hydration states, are detected. The measurements demonstrate the feasibility of using microwave based measurements for hydration monitoring using sweat.
Collapse
Affiliation(s)
- Angie R Eldamak
- Department of Electronics and Electrical Communication Engineering, Faculty of Engineering, Ain Shams University, Cairo 11517, Egypt.
- Schulich School of Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
| | - Elise C Fear
- Schulich School of Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
| |
Collapse
|
11
|
Booth MA, Gowers SAN, Leong CL, Rogers ML, Samper IC, Wickham AP, Boutelle MG. Chemical Monitoring in Clinical Settings: Recent Developments toward Real-Time Chemical Monitoring of Patients. Anal Chem 2017; 90:2-18. [PMID: 29083872 DOI: 10.1021/acs.analchem.7b04224] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Marsilea A Booth
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Sally A N Gowers
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Chi Leng Leong
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Michelle L Rogers
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Isabelle C Samper
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Aidan P Wickham
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Martyn G Boutelle
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| |
Collapse
|
12
|
Garrett DC, Rae N, Fletcher JR, Zarnke S, Thorson S, Hogan DB, Fear EC. Engineering Approaches to Assessing Hydration Status. IEEE Rev Biomed Eng 2017; 11:233-248. [PMID: 29990109 DOI: 10.1109/rbme.2017.2776041] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Dehydration is a common condition characterized by a decrease in total body water. Acute dehydration can cause physical and cognitive impairment, heat stroke and exhaustion, and, if severe and uncorrected, even death. The health effects of chronic mild dehydration are less well studied with urolithiasis (kidney stones) the only condition consistently associated with it. Aside from infants and those with particular medical conditions, athletes, military personnel, manual workers, and older adults are at particular risk of dehydration due to their physical activity, environmental exposure, and/or challenges in maintaining fluid homeostasis. This review describes the different approaches that have been explored for hydration assessment in adults. These include clinical indicators perceived by the patient or detected by a practitioner and routine laboratory analyses of blood and urine. These techniques have variable accuracy and practicality outside of controlled environments, creating a need for simple, portable, and rapid hydration monitoring devices. We review the wide array of devices proposed for hydration assessment based on optical, electromagnetic, chemical, and acoustical properties of tissue and bodily fluids. However, none of these approaches has yet emerged as a reliable indicator in diverse populations across various settings, motivating efforts to develop new methods of hydration assessment.
Collapse
|
13
|
Sempionatto JR, Mishra RK, Martín A, Tang G, Nakagawa T, Lu X, Campbell AS, Lyu KM, Wang J. Wearable Ring-Based Sensing Platform for Detecting Chemical Threats. ACS Sens 2017; 2:1531-1538. [PMID: 29019246 DOI: 10.1021/acssensors.7b00603] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
This work describes a wireless wearable ring-based multiplexed chemical sensor platform for rapid electrochemical monitoring of explosive and nerve-agent threats in vapor and liquid phases. The ring-based sensor system consists of two parts: a set of printed electrochemical sensors and a miniaturized electronic interface, based on a battery-powered stamp-size potentiostat, for signal processing and wireless transmission of data. A wide range of electrochemical capabilities have thus been fully integrated into a 3D printed compact ring structure, toward performing fast square-wave voltammetry and chronoamperometric analyses, along with interchangeable screen-printed sensing electrodes for the rapid detection of different chemical threats. High analytical performance is demonstrated despite the remarkable miniaturization and integration of the ring system. The attractive capabilities of the wearable sensor ring system have been demonstrated for sensitive and rapid voltammetric and amperometric monitoring of nitroaromatic and peroxide explosives, respectively, along with amperometric biosensing of organophosphate (OP) nerve agents. Such ability of the miniaturized wearable sensor ring platform to simultaneously detect multiple chemical threats in both liquid and vapor phases and alert the wearer of such hazards offers considerable promise for meeting the demands of diverse defense and security scenarios.
Collapse
Affiliation(s)
- Juliane R. Sempionatto
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Rupesh K. Mishra
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Aida Martín
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Guangda Tang
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Tatsuo Nakagawa
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Xiaolong Lu
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Alan S. Campbell
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Kay Mengjia Lyu
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Joseph Wang
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| |
Collapse
|
14
|
Non-Invasive Assessment of Skin Barrier Properties: Investigating Emerging Tools for In Vitro and In Vivo Applications. COSMETICS 2017. [DOI: 10.3390/cosmetics4040044] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|