1
|
Gutiérrez A, Ramírez-Ledesma MG, Rivas GA, Luna-Bárcenas G, Escalona-Villalpando RA, Ledesma-García J. Development of an electrochemical sensor for the quantification of ascorbic acid and acetaminophen in pharmaceutical samples. J Pharm Biomed Anal 2024; 249:116334. [PMID: 38976964 DOI: 10.1016/j.jpba.2024.116334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 07/01/2024] [Accepted: 07/02/2024] [Indexed: 07/10/2024]
Abstract
This work presents the modification of glassy carbon electrodes (GCE) by using a dispersion resulting from the non-covalent functionalization of multi-walled carbon nanotubes (MWCNT) with polyarginine (polyArg). MWCNT-polyArg is used for the quantification of ascorbic acid (AA) in the presence of acetaminophen (APAP) and viceversa. Since ascorbic acid and acetaminophen are strongly absorbed on GCE/MWCNT-polyArg, they can be detected in the presence of 4.0×10-5 M acetaminophen (and 3.0×10-5 M ascorbic acid) by using adsorptive stripping with media exchange and differential pulse voltammetry. Using water as the solvent for the MWCNT dispersion, the result was Z-potential of 0.053 ± 0.006 V. The developed sensor showed excellent specificity, sensitivity, stability and reproducibility compared to previously published sensors. The GCE/MWCNT-polyArg sensor shows a fast response time of ∼5 minutes, low limits of detection and quantification for AA (0.95 and 2.9 μM respectively) and APAP (0.27 and 0.82μM, respectively), high sensitivity of 0.0616 μA/M for AA or APAP 0.240μA/M. It was used to test its practicability by determining the concentration of AA or APAP (AA and APAP) in pharmaceutical samples. Finally, the simultaneous measurement of ascorbic acid and acetaminophen in pharmaceuticals showed a good correlation, with a maximum error and RSD of 4.5 and 5.1 %, respectively.
Collapse
Affiliation(s)
- Alejandro Gutiérrez
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico; CONAHCYT, Consejo Nacional de Humanidades, Ciencias y Tecnologías, Av. Insurgentes Sur 1582, Col. Crédito Constructor, Benito Juárez, Ciudad de México 03940, Mexico.
| | - María Guadalupe Ramírez-Ledesma
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico
| | - Gustavo A Rivas
- INFIQC, Departamento de Físico Química, Facultad de Ciencias Químicas, Universidad Nacional de Córdoba, Córdoba 5000, Argentina
| | - Gabriel Luna-Bárcenas
- Tecnológico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Santiago de Querétaro 76130, Mexico
| | - Ricardo A Escalona-Villalpando
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico
| | - Janet Ledesma-García
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico.
| |
Collapse
|
2
|
Chen GY, Luo ML, Chen L, Wang JL, Chai TQ, Wang D, Yang FQ. Selective fluorescence detection of acetylsalicylic acid, succinic acid and ascorbic acid based on a responsive lanthanide metal fluorescent coordination polymer. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:4981-4994. [PMID: 38973656 DOI: 10.1039/d4ay00696h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/09/2024]
Abstract
A fluorescent sensor for highly selective and ultrasensitive detection of acetylsalicylic acid (ASA), succinic acid (SA), and ascorbic acid (AA) was reported. The water-soluble fluorescent ligand salicylic acid (Sal) was generated through catalyzing ASA by the hydrolase activity of zeolitic-imidazolate framework-8 (ZIF-8) or natural esterase (Est). The Sal can coordinate with 2-methylimidazole (2-MIm) and Ln(III) to form a fluorescent lanthanide coordination polymer (LCP), which has a fluorescence emission peak with the maximum wavelength at 412 nm (the excitation wavelength at 300 nm). Therefore, the detection of ASA can be achieved through the fluorescence intensity changes of LCPs in the system, which has comparable sensitivity and good selectivity (linear range of 0.031-1.00 mM and LODs of 11.72 and 3.22 μM) as compared to a direct reaction between Est/ZIF-8 and ASA for detecting ASA (linear range of 0.05-1.20 mM and limits of detection (LODs) of 4.43 and 4.58 μM). Furthermore, upon the addition of SA and AA, the fluorescence intensity of the reaction system can be enhanced and weakened through changing the energy resonance transfer pathways and affecting the enzymatic reaction process, respectively, realizing their sensitive and selective fluorescence detection. The established fluorescent sensors can work well in a wide linear range of SA concentrations from 0 to 2.50 mM (Est-based reaction system) and 0 to 1.50 mM (ZIF-8-based reaction system) with the LODs of 0.032 and 0.028 mM, respectively. The linear ranges of AA concentrations are from 0.0078 to 0.25 mM (Est-based reaction system) and 0.0078 to 0.13 mM (ZIF-8-based reaction system) with the LODs of 2.54 and 3.80 μM, respectively. The established sensors were successfully used in the detection of SA in rabbit plasma, with a recovery of 84.0%-98.7%. Additionally, the contents of ASA in Aspirin Enteric-Coated tablets and AA in vitamin C tablets were also determined by the developed methods.
Collapse
Affiliation(s)
- Guo-Ying Chen
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
| | - Mao-Ling Luo
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
| | - Li Chen
- College of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Key Disciplines Lab of Novel Micro-Nano Devices and System Technology, Chongqing University, Chongqing 400044, China
| | - Jia-Li Wang
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
| | - Tong-Qing Chai
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
| | - Dan Wang
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
| | - Feng-Qing Yang
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
| |
Collapse
|
3
|
Veerapandi G, Sekar C. Binder-free and efficient voltammetric sensor based on Zn-Ca 2CuO 3 nanoparticles for simultaneous determination of amlodipine, acetaminophen, and ascorbic acid in hypertension patients. Mikrochim Acta 2024; 191:409. [PMID: 38898141 DOI: 10.1007/s00604-024-06473-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 05/30/2024] [Indexed: 06/21/2024]
Abstract
Amlodipine (AM) is a long active calcium channel blocker used to relax blood vessels by preventing calcium ion transport into the vascular walls and its supporting molecules acetaminophen (AP) and ascorbic acid (AA) are recommended for hypertension control and prevention. Considering their therapeutic importance and potential side effects due to over dosage, we have fabricated a sensor for individual and simultaneous determination of AA, AP, and AM in pharmaceuticals and human urine using novel Zn-doped Ca2CuO3 nanoparticles modified glassy carbon electrode (GCE). Optimally doped Ca2CuO3 (2.5 wt% Zn at Cu site) enhanced the detection of target molecules over much wider concentration ranges of 50 to 3130 µM for AA, 0.25 to 417 µM for AP, and 0.8 to 354 µM for AM with the corresponding lowest detection limits of 14 µM, 0.05 µM, and 0.07 µM, respectively. Furthermore, the Zn-Ca2CuO3/GCE exhibited excellent selectivity and high sensitivity even in the presence of several potential interfering agents. The usefulness of the developed electrode was tested using an amlodipine besylate tablet and urine samples of seven hypertension patients under medication. The results confirmed the presence of a significant amount of AP and AM in six patients' urine samples indicating that the personalized medication is essential and the quantum of medication need to be fixed by knowing the excess medicines excreted through urine. Thus, the Zn-Ca2CuO3/GCE with a high recovery percentage and good sensitivity shall be useful in the pharmaceutical and biomedical sectors.
Collapse
Affiliation(s)
- G Veerapandi
- Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi, 630003, Tamil Nadu, India
| | - C Sekar
- Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi, 630003, Tamil Nadu, India.
| |
Collapse
|
4
|
Gharous M, Bounab L, Pereira FJ, Choukairi M, López R, Aller AJ. Electrochemical Kinetics and Detection of Paracetamol by Stevensite-Modified Carbon Paste Electrode in Biological Fluids and Pharmaceutical Formulations. Int J Mol Sci 2023; 24:11269. [PMID: 37511028 PMCID: PMC10378910 DOI: 10.3390/ijms241411269] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 06/30/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023] Open
Abstract
Paracetamol (PCT), or acetaminophen, is an important drug used worldwide for various clinical purposes. However, the excessive or indiscriminate use of PCT can provoke liver and kidney dysfunction; hence, it is essential to determine the amount of this target in biological samples. In this work, we develop a quick, simple, and sensitive voltammetric method using chemically modified electrodes to determine PCT in complex matrices, including human serum and commercial solid formulations. We modify the carbon paste electrode with stevensite monoclinic clay mineral (Stv-CPE), using cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy to characterise and detect PCT. The kinetics study provides a better electrochemical characterisation of the electrode behaviour, finding the detection and quantitation limits of 0.2 μM and 0.5 μM under favourable conditions. Further, the best linear working concentration range is 0.6-100 μM for PCT, applying the proposed method to the quantitative determination of PCT content in reference tablet formulations and biological samples for validation.
Collapse
Affiliation(s)
- Moaad Gharous
- Laboratory of Materials and Interfacial Systems, Faculty of Science, Abdelmalek Essaadi University, BP 2121, Tetouan 93002, Morocco
- Research Group of Advanced Materials, Structures and Civil Engineering, National School of Applied Sciences of Tetouan, Abdelmalek Essaadi University, BP 2121, Tetouan 93002, Morocco
| | - Loubna Bounab
- Research Group of Advanced Materials, Structures and Civil Engineering, National School of Applied Sciences of Tetouan, Abdelmalek Essaadi University, BP 2121, Tetouan 93002, Morocco
| | - Fernando J Pereira
- Department of Applied Chemistry and Physics, Faculty of Biological and Environmental Sciences, Campus de Vegazana, s/n, University of León, E-24071 León, Spain
| | - Mohamed Choukairi
- Laboratory of Materials and Interfacial Systems, Faculty of Science, Abdelmalek Essaadi University, BP 2121, Tetouan 93002, Morocco
| | - Roberto López
- Department of Applied Chemistry and Physics, Faculty of Biological and Environmental Sciences, Campus de Vegazana, s/n, University of León, E-24071 León, Spain
| | - A Javier Aller
- Department of Applied Chemistry and Physics, Faculty of Biological and Environmental Sciences, Campus de Vegazana, s/n, University of León, E-24071 León, Spain
| |
Collapse
|
5
|
Haghighian F, Ghoreishi SM, Attaran A, Kashani FZ, Khoobi A. Electrochemical study for simultaneous detection of procaine hydrochloride and its metabolite in biological samples using a nanostructured strong sensor. KOREAN J CHEM ENG 2023. [DOI: 10.1007/s11814-022-1290-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
|
6
|
Preparation of Multiwalled Carbon Nanotubes: Electrochemically Treated Pencil Graphite Electrodes for Nanomolar Detection of L‐Tryptophan in Complex Samples. ChemistrySelect 2022. [DOI: 10.1002/slct.202201697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
7
|
Urçuk A, Yıldız C, Eskiköy Bayraktepe D, Yazan Z. Highly sensitive and disposable electrochemical nano sensor for simultaneous analysis of caffeic acid and uric acid based on halloysite nanotubes and magnetite nanoparticles. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
8
|
Kinetic and thermodynamic studies on the interaction between calf thymus DNA and food additive vanillin - electrochemical methods. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.119434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
9
|
Bismuth nanoparticles decorated on Na-montmorillonite-multiwall carbon nanotube for simultaneous determination of heavy metal ions- electrochemical methods. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116205] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
10
|
Recent Developments in Voltammetric Analysis of Pharmaceuticals Using Disposable Pencil Graphite Electrodes. Processes (Basel) 2022. [DOI: 10.3390/pr10030472] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
The even growing production of both well-known and new derivatives with pharmaceutical action involves the need for developing facile and reliable methods for the analysis of these compounds. Among the widely used instrumental techniques, the electrochemical ones are probably the simplest and the most rapid, also having good performance characteristics. However, the key tool in electroanalysis is the working electrode. Due to the inherent electrochemical and economic advantages of the pencil graphite electrode (PGE), the interest in its applicability in the analysis of different analytes has continuously increased in recent years. Thus, this paper aims to review the scientific reports published in the last 10 years on the use of the disposable eco- and user-friendly PGEs in the electroanalysis of compounds of pharmaceutical importance in different matrices. The PGE characteristics and designs (bare or modified with various types of materials), along with their applications and performance parameters (e.g., linear range, limit of detection, and reproducibility), will be discussed, and their advantages and limitations will be critically emphasized.
Collapse
|
11
|
Dinç E, Ertekin ZC, Büker E. A novel strategy on the spectrochromatographic analysis of a quaternary mixture by parallel factor analysis model. Biomed Chromatogr 2021; 36:e5295. [PMID: 34877675 DOI: 10.1002/bmc.5295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 11/19/2021] [Accepted: 11/22/2021] [Indexed: 11/05/2022]
Abstract
Poor chromatographic resolution is one of the main challenges in chromatographic analysis. Partially separated chromatographic peaks frequently occur, due to the nature of analytes and the demand for fast analysis using high flow rates and shorter columns. Modeling of chromatographic three-way data using suitable chemometric tools enables determining co-eluted peaks without using additional experimental efforts. In this paper, parallel factor analysis (PARAFAC) was applied to chromatographic data for the quantitative resolution of a quaternary mixture at the co-elution condition of acetaminophen, aspirin, ascorbic acid, and guaifenesin in a spectrochromatogram. The spectrochromatograms of the calibration set, validation set, and real samples were arranged as a three-way array. In the next step, the PARAFAC model was implemented to decompose the spectrochromatographic array into trilinear components, corresponding to spectral, chromatographic, and relative concentration profiles of the analytes. The chromatographic and spectral modes were used for the qualitative analysis of components, whereas the analytes in commercial tablets were quantified from their individual profiles in their concentration mode. This study indicated that the application of the PARAFAC model provided a novel strategy for determining overlapping peaks in a chromatogram to perform the analysis of multicomponent mixtures with reduced runtime and without additional efforts.
Collapse
Affiliation(s)
- Erdal Dinç
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Zehra Ceren Ertekin
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Eda Büker
- Department of Basic Pharmaceutical Sciences, Faculty of Pharmacy, Gazi University, Ankara, Turkey
| |
Collapse
|
12
|
Eskiköy Bayraktepe D, İnal EK, Yazan Z. Preparation and characterization of a pencil graphite electrode modified with gold nanoparticles decorated poly (l-methionine) and its use in the simultaneous sensitive electrochemical analysis of ascorbic acid, acetaminophen, chlorpheniramine maleate, and caffeine. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106812] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
13
|
Bayraktepe DE, Yazan Z. Two‐layered Au@Ag Bimetallic Nanocomposites‐poly (L‐Met) Platform for Highly Sensitive Chlorpheniramine Maleate Detection. ELECTROANAL 2021. [DOI: 10.1002/elan.202100422] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
| | - Zehra Yazan
- Ankara University Faculty of Science Department of Chemistry 06560 Ankara/ TURKEY
| |
Collapse
|
14
|
A novel nanostructured poly(thionine)-deep eutectic solvent/CuO nanoparticle film-modified disposable pencil graphite electrode for determination of acetaminophen in the presence of ascorbic acid. Anal Bioanal Chem 2021; 413:1149-1157. [PMID: 33410977 DOI: 10.1007/s00216-020-03078-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 11/12/2020] [Accepted: 11/16/2020] [Indexed: 01/08/2023]
Abstract
A new electrochemical sensor based on thionine (TH), an electroactive polymer, and CuO nanoparticle (CuONP)-modified pencil graphite electrode (PGE) has been developed. Poly(thionine) (PTH) was formed on the CuO/PGE surface by electropolymerisation in ethaline deep eutectic solvent (DES) containing acetic acid dopant to form PTHEthaline/CuO/PGE. Cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulse voltammetry were utilized to evaluate the fabrication process, electrochemical properties, and performance parameters of the modified electrodes. The analytical performance of the PTHEthaline/CuO/PGE was evaluated with respect to linear range, limit of detection, repeatability, and reproducibility for the detection of acetaminophen (APAP) by electrooxidation in the presence of ascorbic acid (AA). Analytical parameters such as pH were optimized. The combined use of PTH and CuONP led to enhanced performance towards APAP due to the large electroactive surface area and synergistic catalytic effect, with a wide linear working range and low detection limit. The reliability of the proposed sensor for the detection of APAP was successfully tested in pharmaceutical samples containing APAP and AA, with very good recoveries. Graphical abstract.
Collapse
|
15
|
Laser scribed graphene: A novel platform for highly sensitive detection of electroactive biomolecules. Biosens Bioelectron 2020; 168:112509. [DOI: 10.1016/j.bios.2020.112509] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 08/03/2020] [Accepted: 08/09/2020] [Indexed: 01/05/2023]
|
16
|
Tkachenko OS, Souza LV, Deon M, Becker EM, Menezes EW, Arenas LT, Benvenutti EV. AgNP‐decorated SBA‐15 for MWCNT Paste Modified Electrode: A Sensor for Simultaneous Voltammetric Determination of Paracetamol and Sulfamethoxazole. ELECTROANAL 2020. [DOI: 10.1002/elan.202060090] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Oleg S. Tkachenko
- Materials Chemistry Department V. N. Karazin Kharkiv National University 4 Svoboda Square Kharkiv 61022 Ukraine
- Institute of Chemistry UFRGS PO Box 15003 CEP 91501-970 Porto Alegre RS Brazil
| | - Luana V. Souza
- Institute of Chemistry UFRGS PO Box 15003 CEP 91501-970 Porto Alegre RS Brazil
| | - Monique Deon
- Institute of Chemistry UFRGS PO Box 15003 CEP 91501-970 Porto Alegre RS Brazil
| | - Emilene M. Becker
- Institute of Chemistry UFRGS PO Box 15003 CEP 91501-970 Porto Alegre RS Brazil
| | - Eliana W. Menezes
- Institute of Chemistry UFRGS PO Box 15003 CEP 91501-970 Porto Alegre RS Brazil
| | - Leliz T. Arenas
- Institute of Chemistry UFRGS PO Box 15003 CEP 91501-970 Porto Alegre RS Brazil
| | | |
Collapse
|