1
|
Li SF, Zhang W, Zhang W, Huang A, Zhu JQ, Wang YJ, Zheng YG. Recent Advances in the Synthesis and Analysis of Atorvastatin and its Intermediates. Curr Med Chem 2024; 31:6063-6083. [PMID: 37828675 DOI: 10.2174/0109298673263728231004053704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 08/22/2023] [Accepted: 09/11/2023] [Indexed: 10/14/2023]
Abstract
Atorvastatin, a lipid-lowering drug that is widely used in the treatment of cardiovascular diseases, has significant clinical significance. This article focuses on the synthetic procedures of atorvastatin, including Paal-Knorr synthesis and several new synthetic strategies. It also outlines chemical and chemo-enzymatic methods for synthesizing optically active side chain of atorvastatin. In addition, a comprehensive overview of the analytical monitoring techniques for atorvastatin and its metabolites and impurities is reported, alongside a discussion of their strengths and limitations.
Collapse
Affiliation(s)
- Shu-Fang Li
- Key Laboratory of Bioorganic Synthesis of Zhejiang Province, College of Biotechnology and Bioengineering, Zhejiang University of Technology, Hangzhou 310014, P.R. China
- Engineering Research Center of Bioconversion and Biopurification of the Ministry of Education, Zhejiang University of Technology, Hangzhou, Zhejiang 310014, P.R. China
- The National and Local Joint Engineering Research Center for Biomanufacturing of Chiral Chemicals, Zhejiang University of Technology, Hangzhou 310014, P.R. China
| | - Wei Zhang
- Key Laboratory of Bioorganic Synthesis of Zhejiang Province, College of Biotechnology and Bioengineering, Zhejiang University of Technology, Hangzhou 310014, P.R. China
- Engineering Research Center of Bioconversion and Biopurification of the Ministry of Education, Zhejiang University of Technology, Hangzhou, Zhejiang 310014, P.R. China
- The National and Local Joint Engineering Research Center for Biomanufacturing of Chiral Chemicals, Zhejiang University of Technology, Hangzhou 310014, P.R. China
| | - Wen Zhang
- Key Laboratory of Bioorganic Synthesis of Zhejiang Province, College of Biotechnology and Bioengineering, Zhejiang University of Technology, Hangzhou 310014, P.R. China
- Engineering Research Center of Bioconversion and Biopurification of the Ministry of Education, Zhejiang University of Technology, Hangzhou, Zhejiang 310014, P.R. China
- The National and Local Joint Engineering Research Center for Biomanufacturing of Chiral Chemicals, Zhejiang University of Technology, Hangzhou 310014, P.R. China
| | - An Huang
- Key Laboratory of Bioorganic Synthesis of Zhejiang Province, College of Biotechnology and Bioengineering, Zhejiang University of Technology, Hangzhou 310014, P.R. China
- Engineering Research Center of Bioconversion and Biopurification of the Ministry of Education, Zhejiang University of Technology, Hangzhou, Zhejiang 310014, P.R. China
- The National and Local Joint Engineering Research Center for Biomanufacturing of Chiral Chemicals, Zhejiang University of Technology, Hangzhou 310014, P.R. China
| | - Jia-Qi Zhu
- Key Laboratory of Bioorganic Synthesis of Zhejiang Province, College of Biotechnology and Bioengineering, Zhejiang University of Technology, Hangzhou 310014, P.R. China
- Engineering Research Center of Bioconversion and Biopurification of the Ministry of Education, Zhejiang University of Technology, Hangzhou, Zhejiang 310014, P.R. China
- The National and Local Joint Engineering Research Center for Biomanufacturing of Chiral Chemicals, Zhejiang University of Technology, Hangzhou 310014, P.R. China
| | - Ya-Jun Wang
- Key Laboratory of Bioorganic Synthesis of Zhejiang Province, College of Biotechnology and Bioengineering, Zhejiang University of Technology, Hangzhou 310014, P.R. China
- Engineering Research Center of Bioconversion and Biopurification of the Ministry of Education, Zhejiang University of Technology, Hangzhou, Zhejiang 310014, P.R. China
- The National and Local Joint Engineering Research Center for Biomanufacturing of Chiral Chemicals, Zhejiang University of Technology, Hangzhou 310014, P.R. China
| | - Yu-Guo Zheng
- Key Laboratory of Bioorganic Synthesis of Zhejiang Province, College of Biotechnology and Bioengineering, Zhejiang University of Technology, Hangzhou 310014, P.R. China
- Engineering Research Center of Bioconversion and Biopurification of the Ministry of Education, Zhejiang University of Technology, Hangzhou, Zhejiang 310014, P.R. China
- The National and Local Joint Engineering Research Center for Biomanufacturing of Chiral Chemicals, Zhejiang University of Technology, Hangzhou 310014, P.R. China
| |
Collapse
|
2
|
Oprica M, Iota M, Daescu M, Fejer SN, Negrila C, Baibarac M. Spectroscopic studies on photodegradation of atorvastatin calcium. Sci Rep 2021; 11:15338. [PMID: 34321518 PMCID: PMC8319406 DOI: 10.1038/s41598-021-94693-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 07/14/2021] [Indexed: 11/09/2022] Open
Abstract
In this work, the photodegradation process of atorvastatin calcium (ATC) is reported as depending on: (1) the presence and the absence of excipients in the solid state; (2) the chemical interaction of ATC with phosphate buffer (PB) having pH equal to 7 and 8; and (3) hydrolysis reaction of ATC in the presence of aqueous solution of NaOH. The novelty of this work consists in the monitoring of the ATC photodegradation by photoluminescence (PL). The exposure of ATC in solid state to UV light induces the photo-oxygenation reactions in the presence of water vapors and oxygen from air. According to the X-ray photoelectron spectroscopic studies, we demonstrate that the photo-oxygenation reaction leads to photodegradation compounds having a high share of C=O bonds compared to ATC before exposure to UV light. Both in the presence of PB and NaOH, the photodegradation process of ATC is highlighted by a significant decrease in the intensity of the PL and photoluminescence excitation (PLE) spectra. According to PLE spectra, the exposure of ATC in the presence of NaOH to UV light leads to the appearance of a new band in the spectral range 340-370 nm, this belonging to the photodegradation products. Arguments concerning the chemical compounds, that resulted in this last case, are shown by Raman scattering and FTIR spectroscopy.
Collapse
Affiliation(s)
- Madalina Oprica
- Laboratory of Optical Processes in Nanostructured Materials, National Institute of Materials Physics, Atomistilor Street 405A, P.O. Box MG-7, 77125, Magurele, Romania
| | - Miruna Iota
- Laboratory of Optical Processes in Nanostructured Materials, National Institute of Materials Physics, Atomistilor Street 405A, P.O. Box MG-7, 77125, Magurele, Romania
| | - Monica Daescu
- Laboratory of Optical Processes in Nanostructured Materials, National Institute of Materials Physics, Atomistilor Street 405A, P.O. Box MG-7, 77125, Magurele, Romania
| | - Szilard N Fejer
- Pro-Vitam Ltd., Muncitorilor Street 16, Sfantu Gheorghe, Romania
| | - Catalin Negrila
- Nanoscale Condensed Matter Laboratory, National Institute of Materials Physics, Atomistilor Street 405A, P.O. Box MG-7, 77125, Magurele, Romania
| | - Mihaela Baibarac
- Laboratory of Optical Processes in Nanostructured Materials, National Institute of Materials Physics, Atomistilor Street 405A, P.O. Box MG-7, 77125, Magurele, Romania.
| |
Collapse
|
3
|
Dispas A, Emonts P, Fillet M. Microchip electrophoresis: A suitable analytical technique for pharmaceuticals quality control? A critical review. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116266] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
4
|
Bahrani S, Ghaedi M, Asfaram A, Mansoorkhani MJK, Javadian H. Rapid ultrasound-assisted microextraction of atorvastatin in the sample of blood plasma by nickel metal organic modified with alumina nanoparticles. J Sep Sci 2020; 43:4469-4479. [PMID: 33048447 DOI: 10.1002/jssc.202000660] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 10/04/2020] [Accepted: 10/05/2020] [Indexed: 12/20/2022]
Abstract
In the present work, nickel-1,4-benzenedioxyacetic acid was synthesized as a rod-like metal organic material and then modified with alumina nanoparticles to synthesize nickel metal organic modified-Al2 O3 nanoparticles. The material was found as an efficient sorbent for the enrichment of atorvastatin in human blood plasma. After the extraction of the sample of plasma by ultrasound-assisted dispersive solid phase extraction, high performance liquid chromatography-ultraviolet was used to determine the quantitatively pre-concentrated interest analyte. The conditions for optimum extraction were achieved by the optimization of the volume of eluent, dosage of the sorbent, and time of sonication. Solution pH of 7.0, 250 μL of ethanol, 45 mg of the sorbent, and 10 min of sonication time were the conditions for extracting the atorvastatin maximum recovery of higher than 97.0%. By using desirability function for the optimization of the process, the present method showed a response that was linear ranging from 0.2 to 800 ng/mL with regression coefficient of 0.999 in the plasma of human blood with a satisfactory detection limit of 0.05 ng/mL, while the precision of interday for the current method was found to be <5%. It can be concluded that dispersive solid phase extraction method is effective for the extraction of atorvastatin from human plasma samples (97.4-102%) due to its easy operation, simplicity, repeatability, and reliability.
Collapse
Affiliation(s)
- Sonia Bahrani
- Department of Chemistry, Yasouj University, Yasuj, Iran
| | | | - Arash Asfaram
- Medicinal Plants Research Center, Yasuj University of Medical Sciences, Yasuj, Iran
| | | | - Hamedreza Javadian
- Universitat Politècnica de Catalunya, Department of Chemical Engineering, ETSEIB, Diagonal 647, Barcelona, Spain
| |
Collapse
|
5
|
Sowińska D, Pogorzelska A, Rakicka M, Sznura J, Janowska J, Gorzycka P, Malak M, Karażniewicz-Łada M. Development and Validation of an RP-HPLC Method for Determination of Atorvastatin and its Hydroxyl Metabolites in Human Plasma. CURR PHARM ANAL 2020. [DOI: 10.2174/1573412914666180912110154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Atorvastatin (AT) belongs to cholesterol-lowering agents, commonly used in
patients with an increased risk of cardiovascular disease. The drug, as well as its hydroxyl metabolites,
exhibit pharmacological activity, and their plasma levels may be helpful in the assessment of the therapeutic
effectiveness.
Objective:
Development and validation of a fast and reproducible RP-HPLC method with UV detection
for the simultaneous determination of atorvastatin and its active metabolites, para-hydroxy-atorvastatin
(p-OH-AT) and ortho-hydroxy-atorvastatin (o-OH-AT) in human plasma.
Methods:
Optimal conditions of chromatographic separation of the analytes, as well as rosuvastatin,
chosen as an internal standard, were studied. The absorbance of the compounds was measured at λ=248
nm. Validation of the method was performed. The usefulness of the method was confirmed for determination
of the analytes in plasma of patients treated with the drug.
Results:
Total peak separation was achieved at LiChrospher 100 RP-18 column with a mobile phase
composed of methanol and water (1:1,v:v) and a flow rate of 1.2 ml/min. The method was linear in the
ranges of 0.025 - 1.0 μg/ml for AT, o-OH-AT and p-OH-AT. Intra- and inter-assay precision expressed
as relative standard deviation was ≤13% for AT, ≤12% for p-OH-AT and ≤11% for o-OH-AT. Intraand
inter-day accuracy of the method, expressed as a relative error, was ≤15%.
Conclusion:
The elaborated HPLC method is specific, repeatable, reproducible, adequately accurate
and precise and fulfills the validation requirements for the bioanalytical method. The method was
successfully applied for analysis of atorvastatin and its o-hydroxy metabolite in plasma of patients
treated with the drug.
Collapse
Affiliation(s)
- Dagmara Sowińska
- Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 6 Swiecickiego Street, 60-781 Poznan, Poland
| | - Alicja Pogorzelska
- Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 6 Swiecickiego Street, 60-781 Poznan, Poland
| | - Marlena Rakicka
- Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 6 Swiecickiego Street, 60-781 Poznan, Poland
| | - Justyna Sznura
- Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 6 Swiecickiego Street, 60-781 Poznan, Poland
| | - Justyna Janowska
- Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 6 Swiecickiego Street, 60-781 Poznan, Poland
| | - Patrycja Gorzycka
- Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 6 Swiecickiego Street, 60-781 Poznan, Poland
| | - Mateusz Malak
- Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 6 Swiecickiego Street, 60-781 Poznan, Poland
| | - Marta Karażniewicz-Łada
- Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 6 Swiecickiego Street, 60-781 Poznan, Poland
| |
Collapse
|
6
|
Attaa Bakr N, Saad S, Elshabrawy Y, Eid M. First-derivative synchronous spectrofluorimetric method for estimation of losartan potassium and atorvastatin in their pure forms and in tablets. LUMINESCENCE 2020; 35:561-571. [PMID: 31957224 DOI: 10.1002/bio.3755] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2019] [Revised: 11/16/2019] [Accepted: 11/26/2019] [Indexed: 11/11/2022]
Abstract
Losartan potassium (LOS) and atorvastatin (ATR) are used in combination for long-term treatment of stroke and for treatment of hypertension with high-level cholesterol. Both drugs were simultaneously determined and validated using a novel, easy, fast, and economical first-derivative synchronous fluorescence spectroscopic method. Methanol was used as the solvent for both drugs at a Δλ 80 nm and with a scanning rate of 600 nm/min. Peaks were determined as at 288.1 nm and 263.6 nm for LOS and ATR, respectively. The proposed method was validated according to International Conference on Harmonization guidelines and, subsequently, the developed method was applicable to the analysis of the two compounds in their different formulations without interference from each other. Amplitude-concentration plots were rectilinear over the concentration ranges 1.0-10.0 μg/ml and 0.5-5.0 μg/ml for LOS and ATR, respectively. Detection limits were found to be 0.096 μg/ml and 0.030 μg/ml and quantitation limits were 0.291 μg/ml and 0.093 μg/ml for LOS and ATR, respectively. The proposed method was successfully applied to the analysis of both compounds in synthetic mixtures and in laboratory-prepared tablets. These results were in accordance with the results acquired using the comparison method, high-performance liquid chromatography.
Collapse
Affiliation(s)
- Norhane Attaa Bakr
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt
| | - Samar Saad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt
| | - Yasser Elshabrawy
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt
| | - Manal Eid
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt
| |
Collapse
|
7
|
Atia NN, Tawfeek HM, Rageh AH, El-Zahry MR, Abdelfattah A, Younis MA. Novel sublingual tablets of Atorvastatin calcium/Trimetazidine hydrochloride combination; HPTLC quantification, in vitro formulation and characterization. Saudi Pharm J 2019; 27:540-549. [PMID: 31061623 PMCID: PMC6488851 DOI: 10.1016/j.jsps.2019.02.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Accepted: 02/04/2019] [Indexed: 01/04/2023] Open
Abstract
Background Ischemic heart disorders and accumulation of lipids in blood vessels could contribute to angina pectoris. Therefore, the aim of this study was to formulate sublingual tablets containing a novel combination of Atorvastatin calcium (ATOR) and Trimetazidine HCl (TMZ) for efficient treatment of coronary heart disorders. Methods The dissolution rate of water-insoluble ATOR was enhanced via complexation with sulfobutyl ether-β-cyclodextrin (SBE-β-CD) and addition of soluplus as a polymeric solubilizer excipient. The solubilized ATOR and TMZ were compressed into a sublingual tablets by direct compression technique and evaluated for their tableting characteristics. In addition, a new validated method based on High Performance Thin Layer Chromatography (HPTLC) was developed for simultaneous determination of both drugs in pure forms and sublingual tablets. Results The developed HPTLC method showed LODs of 0.056 and 0.013 μg/band and LOQs of 0.17, 0.040 μg/band for TMZ and ATOR, respectively and proved to be linear, accurate, precise and robust. The optimum formulation containing mixture of superdisintegrants; Ac-Di-Sol and crospovidone (4.8% w/w, each) showed the shortest disintegration time (65 s) and enhanced release profiles of both drugs. Conclusions The prepared sublingual tablets combining ATOR and TMZ will be a promising dosage form for coronary heart disease patients with an instant action and improved patient compliance.
Collapse
Affiliation(s)
- Noha N Atia
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt
| | - Hesham M Tawfeek
- Department of Industrial Pharmacy, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt.,Department of Pharmaceutics and Pharmaceutical Technology, Faculty of Pharmacy, Mutah University, Karak 61710, Jordan
| | - Azza H Rageh
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt
| | - Marwa R El-Zahry
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt
| | - Ahmed Abdelfattah
- Department of Industrial Pharmacy, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt
| | - Mahmoud A Younis
- Department of Industrial Pharmacy, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt
| |
Collapse
|
8
|
A Low-Cost Palmtop High-Speed Capillary Electrophoresis Bioanalyzer with Laser Induced Fluorescence Detection. Sci Rep 2018; 8:1791. [PMID: 29379053 PMCID: PMC5789010 DOI: 10.1038/s41598-018-20058-0] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2016] [Accepted: 01/12/2018] [Indexed: 12/28/2022] Open
Abstract
In this work, we developed a miniaturized palmtop high-speed capillary electrophoresis (CE) system integrating whole modules, including picoliter-scale sample injection, short capillary-based fast CE, high-voltage power supply, orthogonal laser induced fluorescence (LIF) detection, battery, system control, on-line data acquisition, processing, storage, and display modules. A strategy of minimalist miniaturization combining minimal system design and low-cost system construction was adopted to achieve the instrument miniaturization with extremely low cost, which is differing from the current microfabrication strategy used in most reported miniaturized CE systems. With such a strategy, the total size of the bioanalyzer was minimized to 90 × 75 × 77 mm (length × width × height) and the instrument cost was reduced to ca. $500, which demonstrated the smallest and lowest-cost CE instrument with LIF detection in so far reported systems. The present bioanalyzer also exhibited comparable analytical performances to previously-reported high-speed CE systems. A limit of detection of 1.02 nM sodium fluorescein was obtained. Fast separations were achieved for multiple types of samples as amino acids, amino acid enantiomers, DNA fragments, and proteins with high efficiency. We applied this instrument in colorectal cancer diagnosis for detecting KRAS mutation status by polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method.
Collapse
|
9
|
Kokilambigai KS, Seetharaman R, Lakshmi KS. Critical Review on the Analytical Techniques for the Determination of the Oldest Statin—Atorvastatin—in Bulk, Pharmaceutical Formulations and Biological Fluids. Crit Rev Anal Chem 2017. [DOI: 10.1080/10408347.2017.1342529] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- K. S. Kokilambigai
- Department of Pharmaceutical Analysis, SRM College of Pharmacy, SRM University, Kattankulathur, Kanchipuram, Tamil Nadu, India
| | - R. Seetharaman
- Department of Pharmaceutical Analysis, SRM College of Pharmacy, SRM University, Kattankulathur, Kanchipuram, Tamil Nadu, India
| | - K. S. Lakshmi
- Department of Pharmaceutical Analysis, SRM College of Pharmacy, SRM University, Kattankulathur, Kanchipuram, Tamil Nadu, India
| |
Collapse
|
10
|
Song H, Wang H, Ju S, Jin Q, Jia C, Cong H. Simplified microchip electrophoresis for rapid separation of urine proteins. J Clin Lab Anal 2014; 28:104-9. [PMID: 24395581 DOI: 10.1002/jcla.21651] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2012] [Accepted: 06/03/2013] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND Urine protein test has been widely used in clinics, but to determine the type of proteinuria is usually difficult due to technical limitations. METHODS In the current study, a rapid and simple method to separate and determine urine proteins by a microchip electrophoresis (ME) system has been developed in which only 4 min are required. RESULTS Optimal separation conditions have been established by using 15 s injection time at 500 and 1,500 V separation voltage in 75 mmol/l borate buffer containing 0.8 mmol/l calcium lactate and 1% ϕ ethylamine (pH 10.55). Relative standard deviation (RSD) of migration time with purified human albumin and human transferring was 2.68% and 2.24%, and RSD of the peak area was 5.85% and 4.96%, respectively. The linear detection range was 1.0-15.0 g/l for purified human albumin and 1.0-10.0 g/l for human transferrin, with the same detection limit (S/N = 3) of 0.4 g/l. Finally, comparing to conventional agarose gel electrophoresis, the same results were obtained by using ME by testing clinical samples including 60 selective proteinuria, 105 nonselective proteinuria, and 6 overflow proteinuria. CONCLUSION This newly established ME could have broad applications to determine the type of proteinuria in clinics.
Collapse
Affiliation(s)
- Hongwei Song
- Medical Laboratory Center, Affiliated Hospital of Nantong University, Jiangsu Province, P.R China
| | | | | | | | | | | |
Collapse
|
11
|
Silva TA, Zanin H, Vicentini FC, Corat EJ, Fatibello-Filho O. Differential pulse adsorptive stripping voltammetric determination of nanomolar levels of atorvastatin calcium in pharmaceutical and biological samples using a vertically aligned carbon nanotube/graphene oxide electrode. Analyst 2014; 139:2832-41. [DOI: 10.1039/c4an00111g] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
12
|
Wei SY, Wang LF, Yang YH, Yeh HH, Chen YC, Chen SH. Sample stacking by field-amplified sample injection and sweeping for simultaneous analysis of acidic and basic components in clinic application. Electrophoresis 2012; 33:1571-81. [DOI: 10.1002/elps.201100716] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Shao-Yun Wei
- School of Pharmacy; College of Pharmacy; Kaohsiung Medical University; Kaohsiung; Taiwan
| | - Li-Fang Wang
- Department of Medicinal and Applied Chemistry; Kaohsiung Medical University; Kaohsiung; Taiwan
| | - Yuan-Han Yang
- Department of Neurology; Kaohsiung Medical University Hospital; Kaohsiung; Taiwan
| | - Hsin-Hua Yeh
- School of Pharmacy; College of Pharmacy; Kaohsiung Medical University; Kaohsiung; Taiwan
| | - Yi-Chin Chen
- School of Nursing; College of Nursing; Kaohsiung Medical University; Kaohsiung; Taiwan
| | - Su-Hwei Chen
- School of Pharmacy; College of Pharmacy; Kaohsiung Medical University; Kaohsiung; Taiwan
| |
Collapse
|
13
|
Validated spectrofluorimetric method for the determination of atorvastatin in pharmaceutical preparations. J Pharm Anal 2012; 2:200-205. [PMID: 29403743 PMCID: PMC5760905 DOI: 10.1016/j.jpha.2012.01.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2011] [Accepted: 01/09/2012] [Indexed: 11/22/2022] Open
Abstract
A rapid, sensitive and simple spectrofluorimetric method was developed for the estimation of atorvastatin. In this method, the native fluorescence characteristics of atorvastatin have been studied in both acidic and basic media. High sensitivity was obtained with 5% acetic acid at 389 nm using 276 nm for excitation. Regression analysis showed a good correlation coefficient (r=0.9995) between fluorescence intensity and concentration over the range of 1.5–4 μg/mL with detection limit of 0.012 μg/mL. The proposed method was successfully applied to the analysis of atorvastatin in pure and pharmaceutical dosage forms with average recovery of 100.29±0.47%. The results were compared favorably with those of the reported method.
Collapse
|
14
|
Guihen E, O'Connor WT. Capillary and microchip electrophoresis in microdialysis: recent applications. Electrophoresis 2010; 31:55-64. [PMID: 20039293 DOI: 10.1002/elps.200900467] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The theme of this review is to highlight the importance of microscale electrophoretic-based separation systems in microdialysis (microD). The ability of CE and MCE to yield very rapid and highly efficient separations using just nanolitre volumes of microdialysate samples will also be discussed. Recent advances in this area will be highlighted, by illustration of some exciting new applications while the need for further innovation will be covered. The first section briefly introduces the concept of microD sampling coupled with electrophoresis-based separation and the inherent advantages of this approach. The following section highlights some specific applications of CE separations in the detection of important biomarkers such as low-molecular-weight neurotransmitters, amino acids, and other molecules that are frequently encountered in microD. Various detection modes in CE are outlined and some of the advantages and drawbacks thereof are discussed. The last section introduces the concepts of micro-total analysis systems and the coupling of MCE and microD. Some of the latest innovations will be illustrated. The concluding section reflects on the future of this important chemical alliance between microD and CE/MCE.
Collapse
Affiliation(s)
- Elizabeth Guihen
- Graduate Entry Medical School and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland.
| | | |
Collapse
|
15
|
Strategies for the on-line preconcentration and separation of hypolipidaemic drugs using micellar electrokinetic chromatography. J Chromatogr A 2010; 1217:386-93. [DOI: 10.1016/j.chroma.2009.11.043] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2009] [Revised: 11/13/2009] [Accepted: 11/16/2009] [Indexed: 11/22/2022]
|
16
|
|
17
|
Sisk GD, Herzog G, Glennon JD, Arrigan DWM. Assessment of ion transfer amperometry at liquid-liquid interfaces for detection in CE. Electrophoresis 2009; 30:3366-71. [DOI: 10.1002/elps.200900285] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
18
|
Guihen E, O'Connor WT. Current separation and detection methods in microdialysis the drive towards sensitivity and speed. Electrophoresis 2009; 30:2062-75. [PMID: 19582708 DOI: 10.1002/elps.200900039] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
This review outlines some of the analytical challenges associated with the analysis of microdialysis (MD) samples, in particular, the minute complex sample volumes that are often encountered. In MD sampling many different low-molecular-weight molecules can be collected, but the research findings are often limited by the sensitivity, specificity, and reliability of the analytical technique that is coupled to the dialysis probe. Therefore it is critical that a lot of consideration is given in selecting the most suitable analytical method including the most appropriate detector. This review aims to highlight the strengths and weaknesses of a range of commonly used analytical methods employed in MD. In Section 1, a brief overview of the MD technique is described, followed by a discussion on some of the advantages and drawbacks of this sampling technique. Sections 2 and 3 examine analytical and other technical considerations regarding analysis, with special emphasis on the factors that specifically influence analytical detection. Section 4 outlines the most commonly employed analytical techniques used in MD, including HPLC coupled with various detectors. Detail is given regarding the LOD and LOQ for many applications using each detector. As MS is of such high importance in MD, a special sub-section has been devoted to it. The importance of CE is also highlighted, with specific applications described. In addition, analytical techniques that do not appear to have found routine use in MD are discussed. Section 5 is concerned with recent innovations in chemical separation techniques, in particular MCE and ultra-performance liquid chromatography. Specific applications of the coupling of these techniques with MD are highlighted, along with technical challenges associated with miniaturization. In the Section 6, the future outlook of MD is discussed. Techniques other than electrophoretic- and chromatographic based separation methods are outside the scope of this review.
Collapse
Affiliation(s)
- Elizabeth Guihen
- Graduate Entry Medical School and Material Surface Science Institute, University of Limerick, Limerick, Ireland.
| | | |
Collapse
|
19
|
Nigović B, Damić M, Injac R, Kočevar Glavač N, Štrukelj B. Analysis of Atorvastatin and Related Substances by MEKC. Chromatographia 2009. [DOI: 10.1365/s10337-009-1049-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
20
|
KITAGAWA F, AIZAWA S, OTSUKA K. High-speed Analysis of Proteins by Microchip Isoelectric Focusing with Linear-imaging UV Detection. ANAL SCI 2009; 25:979-84. [DOI: 10.2116/analsci.25.979] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
21
|
Quantification of atorvastatin calcium in tablets by FT-Raman spectroscopy. J Pharm Biomed Anal 2008; 49:168-72. [PMID: 19062220 DOI: 10.1016/j.jpba.2008.10.015] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2008] [Revised: 10/08/2008] [Accepted: 10/10/2008] [Indexed: 11/23/2022]
Abstract
The FT-Raman quantification of atorvastatin calcium in tablets was performed using the partial least squares (PLS), principal component regression (PCR) and counter-propagation artificial neural networks (CP-ANN) methods. To compare the predictive abilities of the elaborated models, the relative standard errors of prediction (RSEP) were calculated. The application of PLS, PCR and 6x6 CP-ANN provided models of comparable quality. RSEP error values in the range of 1.9-2.8% for calibration and validation data sets were obtained for the three procedures applied. Four commercial products containing 10, 20 or 40 mg of atorvastatin calcium per tablet were successfully quantified. Concentrations found from the Raman data analysis correlate strongly with the declared values, with a recovery of 98.5-101.3%, and with the results of reference analysis, with the recovery of 98.9-102.1%, for the different models. The proposed procedure can be a fast, precise and convenient method of atorvastatin calcium quantification in commercial tablets.
Collapse
|
22
|
Pharmaceutical applications of isoelectric focusing on microchip with imaged UV detection. J Chromatogr A 2008; 1181:145-52. [DOI: 10.1016/j.chroma.2007.12.046] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2007] [Revised: 11/20/2007] [Accepted: 12/18/2007] [Indexed: 11/24/2022]
|
23
|
Revermann T, Götz S, Künnemeyer J, Karst U. Quantitative analysis by microchip capillary electrophoresis: current limitations and problem-solving strategies. Analyst 2007; 133:167-74. [PMID: 18227937 DOI: 10.1039/b711165g] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Obstacles and possible solutions for the application of microchip capillary electrophoresis in quantitative analysis are described and critically discussed. Differences between the phenomena occurring during conventional capillary electrophoresis and microchip-based capillary electrophoresis are pointed out, with particular focus on electrolysis, bubble formation, clogging, surface interactions, injection and aspects related to the power supply. Current drawbacks are specified and improvements for successful quantitative microchip capillary electrophoresis are suggested.
Collapse
Affiliation(s)
- Tobias Revermann
- Chemical Analysis Group and MESA+ Institute for Nanotechnology, University of Twente, Enschede, The Netherlands
| | | | | | | |
Collapse
|
24
|
Affiliation(s)
- R K Gilpin
- Brehm Research Laboratory, University Park, Wright State University, Fairborn, Ohio 45324-2031, USA
| | | |
Collapse
|