1
|
Gunasekara DB, Wijesinghe MB, Pichetsurnthorn P, Lunte SM. Evaluation of dual electrode configurations for microchip electrophoresis used for voltammetric characterization of electroactive species. Analyst 2020; 145:865-872. [PMID: 31820743 DOI: 10.1039/c9an02112d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Microchip electrophoresis coupled with amperometric detection is more popular than voltammetric detection due to the lower limits of detection that can be achieved. However, voltammetry provides additional information about the redox properties of the analyte that can be used for peak identification. In this paper, two dual electrode configurations for microchip electrophoresis are described and evaluated for obtaining voltammetric information using amperometry. The dual-series electrode configuration was first evaluated to generate current ratios in a single run by applying two different potentials to the working electrodes placed perpendicular to the separation channel. However, it was found that it is difficult to obtain realistic current ratios with this configuration, primarily due to the relative placement of electrodes with respect to the channel end of the simple-t microchip. Correction factors were needed to obtain current ratios similar to those that would be obtained for sequential injections at two different potentials using a single electrode. A second approach using a dual-channel chip with two parallel electrodes was then developed and evaluated for obtaining voltammetric identification. The newly developed microchip permitted the injection of same amount of sample into two unique separation channels, each with an electrode at a different detection potential. Migration times and current ratios for several biologically important molecules and potential interferences including nitrite, tyrosine, hydrogen peroxide, and azide were obtained and compared to the responses obtained for analytes found in macrophage cell lysates.
Collapse
Affiliation(s)
- Dulan B Gunasekara
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA.
| | | | | | | |
Collapse
|
2
|
Schilly KM, Gunawardhana SM, Wijesinghe MB, Lunte SM. Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis. Anal Bioanal Chem 2020; 412:6101-6119. [PMID: 32347360 PMCID: PMC8130646 DOI: 10.1007/s00216-020-02647-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2020] [Revised: 03/29/2020] [Accepted: 04/06/2020] [Indexed: 01/01/2023]
Abstract
Microchip electrophoresis with amperometric detection (ME-EC) is a useful tool for the determination of redox active compounds in complex biological samples. In this review, a brief background on the principles of ME-EC is provided, including substrate types, electrode materials, and electrode configurations. Several different detection approaches are described, including dual-channel systems for dual-electrode detection and electrochemistry coupled with fluorescence and chemiluminescence. The application of ME-EC to the determination of catecholamines, adenosine and its metabolites, and reactive nitrogen and oxygen species in microdialysis samples and cell lysates is also detailed. Lastly, approaches for coupling of ME-EC with microdialysis sampling to create separation-based sensors that can be used for near real-time monitoring of drug metabolism and neurotransmitters in freely roaming animals are provided. Graphical abstract.
Collapse
Affiliation(s)
- Kelci M Schilly
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, KS, 66045, USA
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, 2030 Becker Drive, Lawrence, KS, 66047, USA
| | - Shamal M Gunawardhana
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, KS, 66045, USA
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, 2030 Becker Drive, Lawrence, KS, 66047, USA
| | - Manjula B Wijesinghe
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, KS, 66045, USA
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, 2030 Becker Drive, Lawrence, KS, 66047, USA
| | - Susan M Lunte
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, KS, 66045, USA.
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, 2030 Becker Drive, Lawrence, KS, 66047, USA.
- Department of Pharmaceutical Chemistry, University of Kansas, 2010 Becker Drive, Lawrence, KS, 66045, USA.
| |
Collapse
|
3
|
Mehl BT, Martin RS. Integrating 3D Cell Culture of PC12 Cells with Microchip-Based Electrochemical Detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2019; 11:1064-1072. [PMID: 31244918 PMCID: PMC6594695 DOI: 10.1039/c8ay02672f] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Developing in vitro cell culture models that accurately mimic in vivo processes in a manner that also enables near real-time analysis of neurotransmitters is an important research area. New technologies being developed such as 3D scaffolds for cell culture and 3D printed microfluidics provide an opportunity for such advancements. In this work, PC12 cells were used as a model system and they were immobilized onto a 3D scaffold of polystyrene (PS) fibers. These fibers were created by electrospinning onto PS sheets, which were laser cut and, after cell seeding, inserted into a 3D printed microfluidic device. The 3D printed device was designed with threads for connecting commercial fittings (to integrate automated pumps and a 4-port injection system) and a steel pin for simple coupling with PDMS/polystyrene analytical devices. A straight PDMS channel was used for simple (and continuous) flow-based detection by sealing onto a PS base containing an embedded gold array working electrode and a platinum pseudo-reference. Electrochemical detection of stimulated catecholamine release was demonstrated. The insert-based system was then integrated with a bilayer valving PDMS device (for microchip electrophoresis) sealed onto a PS base (with electrodes for electrochemical detection). This base was embedded with a Pd decoupler (for grounding the separation voltage and adsorbing hydrogen) and a 33 µm carbon fiber working electrode for in-channel detection. PC12 cells were stimulated in the 3D cell culture device, and the valving/electrophoresis microchip was able to separate and detect dopamine and norepinephrine release. This work demonstrates the ability to integrate 3D cell scaffolds with microchip-based analysis for detection of multiple analytes released from cells.
Collapse
|
4
|
Thompson S, Pappas D. A fluorescence toolbox: A review of investigation of electrophoretic separations, process, and interfaces. Electrophoresis 2018; 40:606-615. [DOI: 10.1002/elps.201800310] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Revised: 09/06/2018] [Accepted: 09/06/2018] [Indexed: 01/23/2023]
Affiliation(s)
- S. Thompson
- Department of Chemistry and Biochemistry; Texas Tech University; Lubbock TX USA
| | - Dimitri Pappas
- Department of Chemistry and Biochemistry; Texas Tech University; Lubbock TX USA
| |
Collapse
|
5
|
Petroni JM, Lucca BG, Ferreira VS. Simple approach for the fabrication of screen-printed carbon-based electrode for amperometric detection on microchip electrophoresis. Anal Chim Acta 2017; 954:88-96. [DOI: 10.1016/j.aca.2016.12.027] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 12/07/2016] [Accepted: 12/19/2016] [Indexed: 10/20/2022]
|
6
|
Mecker LC, Martin RS. Coupling Microdialysis Sampling to Microchip Electrophoresis in a Reversibly Sealed Device. ACTA ACUST UNITED AC 2016; 12:296-302. [PMID: 18836517 DOI: 10.1016/j.jala.2007.04.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
In this paper, we describe the fabrication and characterization of a reversibly sealed microchip device that is used to couple microdialysis sampling to microchip electrophoresis. The ability to interface microdialysis sampling and microchip electrophoresis in a device that is amenable to reversible sealing is advantageous from a repeated use standpoint. Commercially available tubing coming from the microdialysis probe is directly inserted into the chip and flow from the probe is interfaced to the electrophoresis portion of the device through integrated pneumatic valves. Fluorescence detection was used to characterize the poly(dimethylsiloxane)-based device in terms of injection reproducibility. It was found that the entire system (microdialysis probe and microchip device) has a concentration response lag time of 170 sec. Microdialysis sampling followed by an electrophoretic separation of amino acids derivatized with naphthalene-2,3-dicarboxaldehyde/cyanide was also demonstrated.
Collapse
Affiliation(s)
- Laura C Mecker
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | | |
Collapse
|
7
|
Filla LA, Sanders KL, Filla RT, Edwards JL. Automated sample preparation in a microfluidic culture device for cellular metabolomics. Analyst 2016; 141:3858-65. [PMID: 27118418 PMCID: PMC4902300 DOI: 10.1039/c6an00237d] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Sample pretreatment in conventional cellular metabolomics entails rigorous lysis and extraction steps which increase the duration as well as limit the consistency of these experiments. We report a biomimetic cell culture microfluidic device (MFD) which is coupled with an automated system for rapid, reproducible cell lysis using a combination of electrical and chemical mechanisms. In-channel microelectrodes were created using facile fabrication methods, enabling the application of electric fields up to 1000 V cm(-1). Using this platform, average lysing times were 7.12 s and 3.03 s for chips with no electric fields and electric fields above 200 V cm(-1), respectively. Overall, the electroporation MFDs yielded a ∼10-fold improvement in lysing time over standard chemical approaches. Detection of multiple intracellular nucleotides and energy metabolites in MFD lysates was demonstrated using two different MS platforms. This work will allow for the integrated culture, automated lysis, and metabolic analysis of cells in an MFD which doubles as a biomimetic model of the vasculature.
Collapse
Affiliation(s)
- Laura A Filla
- Department of Chemistry, Saint Louis University, St Louis, MO 63130, USA.
| | | | | | | |
Collapse
|
8
|
Zaino LP, Wichert WRA, Crouch GM, Bohn PW. Microchannel Voltammetry in the Presence of Large External Voltages and Electric Fields. Anal Chem 2016; 88:4200-4. [DOI: 10.1021/acs.analchem.6b00399] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Affiliation(s)
- Lawrence P. Zaino
- Department
of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, United States
| | - William R. A. Wichert
- Department
of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, United States
| | - Garrison M. Crouch
- Department
of Chemical and Biomolecular Engineering, University of Notre Dame, Notre
Dame, Indiana 46556, United States
| | - Paul W. Bohn
- Department
of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, United States
- Department
of Chemical and Biomolecular Engineering, University of Notre Dame, Notre
Dame, Indiana 46556, United States
| |
Collapse
|
9
|
Saylor RA, Reid EA, Lunte SM. Microchip electrophoresis with electrochemical detection for the determination of analytes in the dopamine metabolic pathway. Electrophoresis 2015; 36:1912-9. [PMID: 25958983 DOI: 10.1002/elps.201500150] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2015] [Revised: 04/10/2015] [Accepted: 04/14/2015] [Indexed: 12/23/2022]
Abstract
A method for the separation and detection of analytes in the dopamine metabolic pathway was developed using microchip electrophoresis with electrochemical detection. The microchip consisted of a 5 cm PDMS separation channel in a simple-t configuration. Analytes in the dopamine metabolic pathway were separated using a background electrolyte composed of 15 mM phosphate at pH 7.4, 15 mM SDS, and 2.5 mM boric acid. Two different microchip substrates using different electrode materials were compared for the analysis: a PDMS/PDMS device with a carbon fiber electrode and a PDMS/glass hybrid device with a pyrolyzed photoresist film carbon electrode. While the PDMS/PDMS device generated high separation efficiencies and good resolution, more reproducible migration times were obtained with the PDMS/glass hybrid device, making it a better choice for biological applications. Lastly, the optimized method was used to monitor l-DOPA metabolism in a rat brain slice.
Collapse
Affiliation(s)
- Rachel A Saylor
- Department of Chemistry, University of Kansas, Lawrence, KS, USA.,Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
| | - Erin A Reid
- Department of Chemistry, University of Kansas, Lawrence, KS, USA.,Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
| | - Susan M Lunte
- Department of Chemistry, University of Kansas, Lawrence, KS, USA.,Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA.,Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, KS, USA
| |
Collapse
|
10
|
Becirovic V, Doonan SR, Martin RS. Encapsulation of Fluidic Tubing and Microelectrodes in Microfluidic Devices: Integrating Off-Chip Process and Coupling Conventional Capillary Electrophoresis with Electrochemical Detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2013; 5:4220-4229. [PMID: 24159363 PMCID: PMC3804350 DOI: 10.1039/c3ay40809d] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
In this paper, an approach to fabricate epoxy or polystyrene microdevices with encapsulated tubing and electrodes is described. Key features of this approach include a fixed alignment between the fluidic tubing and electrodes, the ability to polish the device when desired, and the low dead volume nature of the fluidic interconnects. It is shown that a variety of tubing can be encapsulated with this approach, including fused silica capillary, polyetheretherketone (PEEK), and perfluoroalkoxy (PFA), with the resulting tubing/microchip interface not leading to significant band broadening or plug dilution. The applicability of the devices with embedded tubing is demonstrated by integrating several off-chip analytical methods to the microchip. This includes droplet transfer, droplet desegmentation, and microchip-based flow injection analysis. Off-chip generated droplets can be transferred to the microchip with minimal coalescence, while flow injection studies showed improved peak shape and sensitivity when compared to the use of fluidic interconnects with an appreciable dead volume. Importantly, it is shown that this low dead volume approach can be extended to also enable the integration of conventional capillary electrophoresis (CE) with electrochemical detection. This is accomplished by embedding fused silica capillary along with palladium (for grounding the electrophoresis voltage) and platinum (for detection) electrodes. With this approach, up to 128,000 theoretical plates for dopamine was possible. In all cases, the tubing and electrodes are housed in a rigid base; this results in extremely robust devices that will be of interest to researchers wanting to develop microchips for use by non-experts.
Collapse
Affiliation(s)
| | | | - R. Scott Martin
- Corresponding author: phone: 314-977-2836, fax: 314-977-2521,
| |
Collapse
|
11
|
Selimovic A, Martin RS. Encapsulated electrodes for microchip devices: microarrays and platinized electrodes for signal enhancement. Electrophoresis 2013; 34:2092-100. [PMID: 23670668 PMCID: PMC3760495 DOI: 10.1002/elps.201300163] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2013] [Revised: 04/10/2013] [Accepted: 04/10/2013] [Indexed: 12/20/2022]
Abstract
In this paper, we present two new methodologies of improving the performance of microchip-based electrochemical detection in microfluidic devices. The first part describes the fabrication and characterization of epoxy-embedded gold microelectrode arrays that are evenly spaced and easily modified. Electrodepositions using a gold plating solution can be performed on the electrodes to result in a 3D pillar array that, when used with microchip-based flow injection analysis, leads to an eightfold increase in signal (when compared to a single electrode), with the LOD for catechol being 4 nM. For detecting analytically challenging molecules such as nitric oxide (NO), platinization of electrodes is commonly used to increase the sensitivity. It is shown here that microchip devices containing either the pillar arrays or more traditional glassy carbon electrodes can be modified with platinum black (Pt-black) for NO detection. In the case of using glassy carbon electrodes for NO detection, integration of the resulting platinized electrode with microchip-based flow analysis resulted in a ten times signal increase relative to use of a bare glassy carbon electrode. In addition, it is demonstrated that these electrodes can be coated with Nafion to impart selectivity toward NO over interfering species such as nitrite. The LOD for NO when using the Pt-black /Nafion-coated glassy carbon electrode was 9 nM. These electrodes can also be embedded in a polystyrene substrate, with the applicability of these sensitive and selective electrodes being demonstrated by monitoring the adenosine triphosphate-mediated release of NO from endothelial cells immobilized in a microfluidic network without any adhesion factor.
Collapse
Affiliation(s)
- Asmira Selimovic
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|
12
|
Dorris MK, Crick EW, Lunte CE. A parallel dual-electrode detector for capillary electrophoresis. Electrophoresis 2012; 33:2725-32. [PMID: 22965718 DOI: 10.1002/elps.201200113] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
An approach to on-capillary dual-electrode detection for CE using a parallel electrode configuration has been developed. The parallel configuration provides two operating modes. In the first mode, one working electrode is held at an oxidizing potential and the second working electrode is held at a reducing potential. This results in redox cycling of analytes between the oxidized and reduced forms, enhancing sensitivity compared to single-electrode detection. In the second mode, both working electrodes are held at different oxidizing potentials. This mode provides electrochemical characterization of electrophoretic peaks. In the redox cyclying mode, signal enhancement of up to twofold was observed for the dual-electrode detection of phenolic acid standards compared to single-electrode detection. Variation in response of less than 10% from electrode to electrode was determined (at a concentration of 60 nM) indicating reproducible fabrication. LODs were determined to be as low as 5.0 nM for dual-electrode configuration. Using the dual-potential mode peak identification of targeted phenolic acids in whiskey samples were confirmed based on both migration time and current ratios.
Collapse
Affiliation(s)
- Megan K Dorris
- Department of Chemistry, Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS 66047, USA
| | | | | |
Collapse
|
13
|
Johnson AS, Anderson KB, Halpin ST, Kirkpatrick DC, Spence DM, Martin RS. Integration of multiple components in polystyrene-based microfluidic devices part I: fabrication and characterization. Analyst 2012; 138:129-36. [PMID: 23120747 DOI: 10.1039/c2an36168j] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
In Part I of a two-part series, we describe a simple and inexpensive approach to fabricate polystyrene devices that is based upon melting polystyrene (from either a Petri dish or powder form) against PDMS molds or around electrode materials. The ability to incorporate microchannels in polystyrene and integrate the resulting device with standard laboratory equipment such as an optical plate reader for analyte readout and pipets for fluid propulsion is first described. A simple approach for sample and reagent delivery to the device channels using a standard, multi-channel micropipette and a PDMS-based injection block is detailed. Integration of the microfluidic device with these off-chip functions (sample delivery and readout) enables high-throughput screens and analyses. An approach to fabricate polystyrene-based devices with embedded electrodes is also demonstrated, thereby enabling the integration of microchip electrophoresis with electrochemical detection through the use of a palladium electrode (for a decoupler) and carbon-fiber bundle (for detection). The device was sealed against a PDMS-based microchannel and used for the electrophoretic separation and amperometric detection of dopamine, epinephrine, catechol, and 3,4-dihydroxyphenylacetic acid. Finally, these devices were compared against PDMS-based microchips in terms of their optical transparency and absorption of an anti-platelet drug, clopidogrel. Part I of this series lays the foundation for Part II, where these devices were utilized for various on-chip cellular analysis.
Collapse
Affiliation(s)
- Alicia S Johnson
- Department of Chemistry, Saint Louis University, St. Louis, Missouri 63103, USA
| | | | | | | | | | | |
Collapse
|
14
|
Johnson AS, Selimovic A, Martin RS. Integration of microchip electrophoresis with electrochemical detection using an epoxy-based molding method to embed multiple electrode materials. Electrophoresis 2011; 32:3121-8. [PMID: 22038707 PMCID: PMC3314886 DOI: 10.1002/elps.201100433] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2011] [Revised: 09/01/2011] [Accepted: 09/02/2011] [Indexed: 11/08/2022]
Abstract
This paper describes the use of epoxy-encapsulated electrodes to integrate microchip-based electrophoresis with electrochemical detection. Devices with various electrode combinations can easily be developed. This includes a palladium decoupler with a downstream working electrode material of either gold, mercury/gold, platinum, glassy carbon, or a carbon fiber bundle. Additional device components such as the platinum wires for the electrophoresis separation and the counter electrode for detection can also be integrated into the epoxy base. The effect of the decoupler configuration was studied in terms of the separation performance, detector noise, and the ability to analyze samples of a high ionic strength. The ability of both glassy carbon and carbon fiber bundle electrodes to analyze a complex mixture was demonstrated. It was also shown that a PDMS-based valving microchip can be used along with the epoxy-embedded electrodes to integrate microdialysis sampling with microchip electrophoresis and electrochemical detection, with the microdialysis tubing also being embedded in the epoxy substrate. This approach enables one to vary the detection electrode material as desired in a manner where the electrodes can be polished and modified as is done with electrochemical flow cells used in liquid chromatography.
Collapse
Affiliation(s)
- Alicia S. Johnson
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - Asmira Selimovic
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|
15
|
Cioffi AG, Martin RS, Kiss IZ. Electrochemical Oscillations of Nickel Electrodissolution in an Epoxy-Based Microchip Flow Cell. J Electroanal Chem (Lausanne) 2011; 659:92-100. [PMID: 21822407 PMCID: PMC3150514 DOI: 10.1016/j.jelechem.2011.05.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
We investigate the nonlinear dynamics of transpassive electrodissolution of nickel in sulfuric acid in an epoxy-based microchip flow cell. We observed bistability, smooth, relaxation, and period-2 waveform current oscillations with external resistance attached to the electrode in the microfabricated electrochemical cell with 0.05 mm diameter Ni wire under potentiostatic control. Experiments with 1mm × 0.1 mm Ni electrode show spontaneous oscillations without attached external resistance; similar surface area electrode in macrocell does not exhibit spontaneous oscillations. Combined experimental and numerical studies show that spontaneous oscillation with the on-chip fabricated electrochemical cell occurs because of the unusually large ohmic potential drop due to the constrained current in the narrow flow channel. This large IR potential drop is expected to have an important role in destabilizing negative differential resistance electrochemical (e.g., metal dissolution and electrocatalytic) systems in on-chip integrated microfludic flow cells. The proposed experimental setup can be extendend to multi-electrode configurations; the epoxy-based substrate procedure thus holds promise in electroanalytical applications that require collector-generator multi-electrodes wires with various electrode sizes, compositions, and spacings as well as controlled flow conditions.
Collapse
Affiliation(s)
- Alexander G. Cioffi
- Saint Louis University, Department of Chemistry, 3501 Laclede Ave., St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Ave., St. Louis, MO 63103
| | - István Z. Kiss
- Saint Louis University, Department of Chemistry, 3501 Laclede Ave., St. Louis, MO 63103
| |
Collapse
|
16
|
Filla LA, Kirkpatrick DC, Martin RS. Use of a corona discharge to selectively pattern a hydrophilic/hydrophobic interface for integrating segmented flow with microchip electrophoresis and electrochemical detection. Anal Chem 2011; 83:5996-6003. [PMID: 21718004 DOI: 10.1021/ac201007s] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Segmented flow in microfluidic devices involves the use of droplets that are generated either on- or off-chip. When used with off-chip sampling methods, segmented flow has been shown to prevent analyte dispersion and improve temporal resolution by periodically surrounding an aqueous flow stream with an immiscible carrier phase as it is transferred to the microchip. To analyze the droplets by methods such as electrochemistry or electrophoresis, a method to "desegment" the flow into separate aqueous and immiscible carrier phase streams is needed. In this paper, a simple and straightforward approach for this desegmentation process was developed by first creating an air/water junction in natively hydrophobic and perpendicular PDMS channels. The air-filled channel was treated with a corona discharge electrode to create a hydrophilic/hydrophobic interface. When a segmented flow stream encounters this interface, only the aqueous sample phase enters the hydrophilic channel, where it can be subsequently analyzed by electrochemistry or microchip-based electrophoresis with electrochemical detection. It is shown that the desegmentation process does not significantly degrade the temporal resolution of the system, with rise times as low as 12 s reported after droplets are recombined into a continuous flow stream. This approach demonstrates significant advantages over previous studies in that the treatment process takes only a few minutes, fabrication is relatively simple, and reversible sealing of the microchip is possible. This work should enable future studies in which off-chip processes such as microdialysis can be integrated with segmented flow and electrochemical-based detection.
Collapse
Affiliation(s)
- Laura A Filla
- Department of Chemistry, Saint Louis University, St. Louis, Missouri 63103, United States
| | | | | |
Collapse
|
17
|
Selimovic A, Johnson AS, Kiss IZ, Martin RS. Use of epoxy-embedded electrodes to integrate electrochemical detection with microchip-based analysis systems. Electrophoresis 2011; 32:822-31. [PMID: 21413031 PMCID: PMC3085833 DOI: 10.1002/elps.201000665] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2010] [Revised: 01/11/2011] [Accepted: 01/11/2011] [Indexed: 11/09/2022]
Abstract
A new method of fabricating electrodes for microchip devices that involves the use of Teflon molds and a commercially available epoxy to embed electrodes of various sizes and compositions is described. The resulting epoxy base can be polished to generate a fresh electrode and sealed against poly(dimethylsiloxane) (PDMS)-based fluidic structures. Microchip-based flow injection analysis was used to characterize the epoxy-embedded electrodes. It was shown that gold electrodes can be amalgamated with liquid mercury and the resulting mercury/gold electrode is used to selectively detect glutathione from lysed red blood cells. The ability to encapsulate multiple electrode materials of differing compositions enabled the integration of microchip electrophoresis with electrochemical detection. Finally, a unique feature of this approach is that the electrode connection is made from the bottom of the epoxy base. This enables the creation of three-dimensional gold pillar electrodes (65 μm in diameter and 27 μm in height) that can be integrated within a fluidic network. As compared with the use of a flat electrode of a similar diameter, the use of the pillar electrode led to improvements in both the sensitivity (72.1 pA/μM for the pillar versus 4.2 pA/μM for the flat electrode) and limit of detection (20 nM for the pillar versus 600 nM for the flat electrode), with catechol being the test analyte. These epoxy-embedded electrodes hold promise for the creation of inexpensive microfluidic devices that can be used to electrochemically detect biologically important analytes in a manner where the electrodes can be polished and a fresh electrode surface is generated as desired.
Collapse
Affiliation(s)
- Asmira Selimovic
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - Alicia S. Johnson
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - István Z. Kiss
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|
18
|
Gunasekara DB, Hulvey MK, Lunte SM. In-channel amperometric detection for microchip electrophoresis using a wireless isolated potentiostat. Electrophoresis 2011; 32:832-7. [PMID: 21437918 DOI: 10.1002/elps.201000681] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2010] [Revised: 01/15/2011] [Accepted: 01/16/2011] [Indexed: 11/07/2022]
Abstract
The combination of microchip electrophoresis with amperometric detection leads to a number of analytical challenges that are associated with isolating the detector from the high voltages used for the separation. While methods such as end-channel alignment and the use of decouplers have been employed, they have limitations. A less common method has been to utilize an electrically isolated potentiostat. This approach allows placement of the working electrode directly in the separation channel without using a decoupler. This paper explores the use of microchip electrophoresis and electrochemical detection with an electrically isolated potentiostat for the separation and in-channel detection of several biologically important anions. The separation employed negative polarity voltages and tetradecyltrimethylammonium bromide (as a buffer modifier) for the separation of nitrite (NO₂⁻), glutathione, ascorbic acid, and tyrosine. A half-wave potential shift of approximately negative 500 mV was observed for NO₂⁻ and H₂O₂ standards in the in-channel configuration compared to end-channel. Higher separation efficiencies were observed for both NO₂⁻ and H₂O₂ with the in-channel detection configuration. The limits of detection were approximately two-fold lower and the sensitivity was approximately two-fold higher for in-channel detection of nitrite when compared to end-channel. The application of this microfluidic device for the separation and detection of biomarkers related to oxidative stress is described.
Collapse
Affiliation(s)
- Dulan B Gunasekara
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, Kansas, USA
| | | | | |
Collapse
|
19
|
Opekar F, Štulík K. Some important combinations of detection techniques for electrophoresis in capillaries and on chips with emphasis on electrochemical principles. Electrophoresis 2011; 32:795-810. [DOI: 10.1002/elps.201000455] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2010] [Revised: 10/01/2010] [Accepted: 10/07/2010] [Indexed: 11/08/2022]
|
20
|
Bowen AL, Martin RS. Integration of on-chip peristaltic pumps and injection valves with microchip electrophoresis and electrochemical detection. Electrophoresis 2010; 31:2534-40. [PMID: 20665914 DOI: 10.1002/elps.201000029] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
A microfluidic approach that integrates peristaltic pumping from an on-chip reservoir with injection valves, microchip electrophoresis and electrochemical detection is described. Fabrication and operation of both the peristaltic pumps and injection valves were optimized to ensure efficient pumping and discrete injections. The final device uses the peristaltic pumps to continuously direct sample from a reservoir containing a mixture of analytes to injection valves that are coupled with microchip electrophoresis and amperometric detection. The separation and direct detection of dopamine and norepinephrine were possible with this approach and the utility of the device was demonstrated by monitoring the stimulated release of these neurotransmitters from a layer of cells introduced into the microchip. It is also shown that this pumping/reservoir approach can be expanded to multiple reservoirs and pumps, where one reservoir can be addressed individually or multiple reservoirs sampled simultaneously.
Collapse
Affiliation(s)
- Amanda L Bowen
- Department of Chemistry, Saint Louis University, St. Louis, MO 63103, USA
| | | |
Collapse
|
21
|
Mecker LC, Filla LA, Martin RS. Use of a Carbon-ink Microelectrode Array for Signal Enhancement in Microchip Electrophoresis with Electrochemical Detection. ELECTROANAL 2010; 22:2141-2146. [PMID: 21572540 PMCID: PMC3092702 DOI: 10.1002/elan.201000118] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2010] [Accepted: 03/11/2010] [Indexed: 11/09/2022]
Abstract
In this communication, we demonstrate that a carbon ink microelectrode array, where the electrodes are held at the same potential, affords significant signal enhancement in microchip electrophoresis with amperometric detection. The ability to fabricate an array of carbon ink microelectrodes with a palladium decoupler was demonstrated and the resulting electrodes were integrated with a valving microchip design. The use of an 8 electrode array led to a significant improvement in the limits of detection at the expense of separation resolution due to the increased detection zone size. It is also shown that microdialysis sampling can be integrated with the microchip device and a multi-analyte separation achieved.
Collapse
Affiliation(s)
- Laura C. Mecker
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - Laura A. Filla
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|
22
|
Kirkpatrick DC, Antwi C, Martin RS. Use of Recordable Compact Discs to Fabricate Electrodes for Microchip-based Analysis Systems. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2010; 2:811-816. [PMID: 21031142 PMCID: PMC2963460 DOI: 10.1039/c0ay00294a] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
This work demonstrates that recordable compact discs (CDs) that contain gold as a reflective layer can be used as an electrode substrate for microchip-based analysis systems. A fabrication procedure that enables the reproducible patterning of multiple electrodes has been developed. It is shown that the microelectrodes can be integrated within a PDMS-based fluidic network and used for amperometric detection of electroactive analytes at both single and dual microelectrodes. A detailed comparison is made between the CD-based patterned electrodes and electrodes made by the traditional method of sputtering gold and titanium adhesion layers onto a glass substrate. It is also shown that mercury can be electrodeposited onto a CD-based microelectrode and the amalgam electrode used to selectively detect thiols. Finally, it is demonstrated that a decoupler for microchip-based electrophoresis can be made by electrodepositing palladium onto a gold electrode and a separate downstream gold working electrode can be used for amperometric detection. These CD-based patterned electrodes are attractive alternatives for situations where device cost is of a concern or sputtering facilities are unavailable.
Collapse
Affiliation(s)
- Douglas C. Kirkpatrick
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - Christiana Antwi
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|
23
|
Du F, Fung YS. Development of CE-dual opposite carbon-fiber micro-disk electrode detection for peak purity assessment of polyphenols in red wine. Electrophoresis 2010; 31:2192-9. [DOI: 10.1002/elps.200900713] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
24
|
Bowen AL, Martin RS. Integration of serpentine channels for microchip electrophoresis with a palladium decoupler and electrochemical detection. Electrophoresis 2010; 30:3347-54. [PMID: 19739137 DOI: 10.1002/elps.200900234] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Although it has been shown that microchip electrophoresis (MCE) with electrochemical detection can be used to separate and detect electroactive species, there is a need to increase the separation performance of these devices so that complex mixtures can be routinely analyzed. Previous work in the MCE has demonstrated that increasing the separation channel length leads to an increase in resolution between closely eluting analytes. This paper details the use of lengthened serpentine microchannels for MCE and electrochemical detection where a palladium decoupler is used to ground the separation voltage so that the working electrodes remain in the fluidic network. In this work, palladium electrodepositions were used to increase the decoupler surface area and more efficiently dissipate hydrogen produced at the decoupler. Dopamine and norepinephrine, which only differ in structure by a hydroxyl group, were used as model analytes. It was found that increasing the separation channel length led to improvements in both the resolution and the number of theoretical plates for these analytes. The use of a bilayer valving device, where PDMS-based valves are utilized for the injection process, along with serpentine microchannels and amperometric detection resulted in a multianalyte separation and an average of 28 700 theoretical plates. It was also shown that the increased channel length is beneficial when separating and detecting analytes from a high ionic strength matrix. This was demonstrated by monitoring the stimulated release of neurotransmitters from a confluent layer of PC 12 cells.
Collapse
Affiliation(s)
- Amanda L Bowen
- Department of Chemistry, Saint Louis University, St. Louis, MO 63103, USA
| | | |
Collapse
|
25
|
Fischer DJ, Hulvey MK, Regel AR, Lunte SM. Amperometric detection in microchip electrophoresis devices: effect of electrode material and alignment on analytical performance. Electrophoresis 2010; 30:3324-33. [PMID: 19802847 DOI: 10.1002/elps.200900317] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The fabrication and evaluation of different electrode materials and electrode alignments for microchip electrophoresis with electrochemical detection is described. The influences of electrode material, both metal and carbon-based, on sensitivity and LOD were examined. In addition, the effects of working electrode alignment on analytical performance (in terms of peak shape, resolution, sensitivity, and LOD) were directly compared. Using dopamine (DA), norepinephrine, and catechol (CAT) as test analytes, it was found that pyrolyzed photoresist electrodes with end-channel alignment yielded the lowest LOD (35 nM for DA). In addition to being easier to implement, end-channel alignment also offered better analytical performance than off-channel alignment for the detection of all three analytes. In-channel electrode alignment resulted in a 3.6-fold reduction in peak skew and reduced peak tailing by a factor of 2.1 for CAT in comparison to end-channel alignment.
Collapse
Affiliation(s)
- David J Fischer
- Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, KS, USA
| | | | | | | |
Collapse
|
26
|
Kiss IZ, Munjal N, Martin RS. Synchronized Current Oscillations of Formic Acid Electro-oxidation in a Microchip-based Dual-Electrode Flow Cell. Electrochim Acta 2009; 55:395-403. [PMID: 20160883 PMCID: PMC2772206 DOI: 10.1016/j.electacta.2009.02.094] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
We investigate the oscillatory electro-oxidation of formic acid on platinum in a microchip-based dual-electrode cell with microfluidic flow control. The main dynamical features of current oscillations on single Pt electrode that had been observed in macro-cells are reproduced in the microfabricated electrochemical cell. In dual-electrode configuration nearly in-phase synchronized current oscillations occur when the reference/counter electrodes are placed far away from the microelectrodes. The synchronization disappears with close reference/counter electrode placements. We show that the cause for synchronization is weak albeit important, bidirectional electrical coupling between the electrodes; therefore the unidirectional mass transfer interactions are negligible. The experimental design enables the investigation of the dynamical behavior in micro-electrode arrays with well-defined control of flow of the electrolyte in a manner where the size and spacing of the electrodes can be easily varied.
Collapse
Affiliation(s)
- István Z. Kiss
- Saint Louis University, Department of Chemistry, 3501 Laclede Ave., St. Louis, MO 63103
| | - Neil Munjal
- Saint Louis University, Department of Chemistry, 3501 Laclede Ave., St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Ave., St. Louis, MO 63103
| |
Collapse
|
27
|
Holcomb RE, Kraly JR, Henry CS. Electrode array detector for microchip capillary electrophoresis. Analyst 2008; 134:486-92. [PMID: 19238284 DOI: 10.1039/b816289a] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Selectivity and resolution for analyses conducted using microfluidic devices can be improved by increasing the total number of individual detection elements in the device. Here, a poly(dimethylsiloxane) capillary electrophoresis microchip was fabricated with an integrated electrode array for selective detection of small molecules. Eight individually addressable gold electrodes were incorporated in series after a palladium current decoupler in the separation channel of an electrophoresis microchip. The electrode array device was characterized using a mixture of biologically relevant analytes and xenobiotics: norepinephrine, 4-aminophenol, acetaminophen, uric acid, and 3,4-dihydroxyphenylacetic acid. Separation efficiencies as high as 9000 +/- 1000 plates (n = 3) for 3,4-dihydroxyphenylacetic acid and limits of detection as low as 2.6 +/- 1.2 microM (n = 3) for norepinephrine were obtained using this device. After characterizing the performance of the device, potential step detection was conducted at the array electrodes and selective detection achieved based upon differences in redox potentials for individual analytes. Utilization of potential step detection was particularly advantageous for resolving co-migrating species; resolution of 3,4-dihydroxy-l-phenylalanine from acetaminophen using potential control was demonstrated. Finally, a human urine sample was analyzed using potential step detection to demonstrate the applicability of this device for complex sample analysis.
Collapse
Affiliation(s)
- Ryan E Holcomb
- Department of Chemistry, Colorado State University, Fort Collins, CO 80523-1872, USA
| | | | | |
Collapse
|
28
|
Mecker LC, Martin RS. Integration of microdialysis sampling and microchip electrophoresis with electrochemical detection. Anal Chem 2008; 80:9257-64. [PMID: 19551945 PMCID: PMC2771943 DOI: 10.1021/ac801614r] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Here we describe the fabrication, optimization, and application of a microfluidic device that integrates microdialysis (MD) sampling, microchip electrophoresis (ME), and electrochemical detection (EC). The manner in which the chip is produced is reproducible and enables the fixed alignment of the MD/ME and ME/EC interfaces. Poly(dimethylsiloxane) (PDMS)-based valves were used for the discrete injection of sample from the hydrodynamic MD dialysate stream into a separation channel for analysis with ME. To enable the integration of ME with EC detection, a palladium decoupler was used to isolate the high voltages associated with electrophoresis from micrometer-sized carbon ink detection electrodes. Optimization of the ME/EC interface was needed to allow the use of biologically appropriate perfusate buffers containing high salt content. This optimization included changes in the fabrication procedure, increases in the decoupler surface area, and a programmed voltage shutoff. The ability of the MD/ME/EC system to sample a biological system was demonstrated by using a linear probe to monitor the stimulated release of dopamine from a confluent layer of PC 12 cells. To our knowledge, this is the first report of a microchip-based system that couples microdialysis sampling with microchip electrophoresis and electrochemical detection.
Collapse
Affiliation(s)
- Laura C. Mecker
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|
29
|
Li MW, Martin RS. Microchip-based integration of cell immobilization, electrophoresis, post-column derivatization, and fluorescence detection for monitoring the release of dopamine from PC 12 cells. Analyst 2008; 133:1358-66. [PMID: 18810283 DOI: 10.1039/b807093h] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
In this paper, we describe the fabrication and evaluation of a multilayer microchip device that can be used to quantitatively measure the amount of catecholamines released from PC 12 cells immobilized within the same device. This approach allows immobilized cells to be stimulated on-chip and, through rapid actuation of integrated microvalves, the products released from the cells are repeatedly injected into the electrophoresis portion of the microchip, where the analytes are separated based upon mass and charge and detected through post-column derivatization and fluorescence detection. Following optimization of the post-column derivatization detection scheme (using naphthalene-2,3-dicarboxaldehyde and 2-beta-mercaptoethanol), off-chip cell stimulation experiments were performed to demonstrate the ability of this device to detect dopamine from a population of PC 12 cells. The final 3-dimensional device that integrates an immobilized PC 12 cell reactor with the bilayer continuous flow sampling/electrophoresis microchip was used to continuously monitor the on-chip stimulated release of dopamine from PC 12 cells. Similar dopamine release was seen when stimulating on-chip versus off-chip yet the on-chip immobilization studies could be carried out with 500 times fewer cells in a much reduced volume. While this paper is focused on PC 12 cells and neurotransmitter analysis, the final device is a general analytical tool that is amenable to the immobilization of a variety of cell lines and analysis of various released analytes by electrophoretic means.
Collapse
Affiliation(s)
- Michelle W Li
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103, USA
| | | |
Collapse
|
30
|
Liu C, Mo YY, Chen ZG, Li X, Li OL, Zhou X. Dual fluorescence/contactless conductivity detection for microfluidic chip. Anal Chim Acta 2008; 621:171-7. [DOI: 10.1016/j.aca.2008.05.040] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2008] [Revised: 05/09/2008] [Accepted: 05/13/2008] [Indexed: 10/22/2022]
|
31
|
Hulvey MK, Genes LI, Spence DM, Martin RS. Fabrication and evaluation of a 3-dimensional microchip device where carbon microelectrodes individually address channels in the separate fluidic layers. Analyst 2008; 132:1246-53. [PMID: 18318286 DOI: 10.1039/b711148g] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A fabrication method that results in a 3-dimensional fluidic device containing poly(dimethylsiloxane) (PDMS) -embedded microelectrodes that individually address each layer is described. The two electrode-containing layers and the polycarbonate membrane are reversibly sealed together, eliminating the need for plasma oxidation during device assembly, while enabling simultaneous amperometric detection in membrane-separated fluidic channels. The electrodes were characterized using microchip-based flow analysis. It was found that PDMS-embedded electrodes have a limit of detection (400 nM for catechol) that is 5-fold lower than that reported for microchip-based flow analysis with similar electrodes in a hybrid PDMS-glass device. The selectivity of the carbon ink microelectrodes can be tuned by a simplified modification procedure; this was demonstrated by the selective detection of nitric oxide over possible interferents. Finally, the ability to monitor processes occurring in separate layers of a 3-dimensional device was shown by the simultaneous detection of catechol on either side of the polycarbonate membrane. The electrode response in each fluidic channel was found to be linear as a function of concentration and the transport between layers could be controlled by varying the linear velocities of each fluidic channel. The ability to fabricate and operate this type of 3-dimensional device will be useful for the development of cell-based in vivo mimics that involve the transport of molecular messengers and/or pharmaceuticals across layers of immobilized cells.
Collapse
Affiliation(s)
- Matthew K Hulvey
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103, USA
| | | | | | | |
Collapse
|
32
|
Ordeig O, Godino N, del Campo J, Muñoz FX, Nikolajeff F, Nyholm L. On-Chip Electric Field Driven Electrochemical Detection Using a Poly(dimethylsiloxane) Microchannel with Gold Microband Electrodes. Anal Chem 2008; 80:3622-32. [DOI: 10.1021/ac702570p] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Olga Ordeig
- Centro Nacional de Microelectrónica, IMB-CNM, CSIC, Campus de la Universidad, Autónoma de Barcelona, Esfera UAB, Bellaterra-08193, Spain, Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden, and Department of Materials Chemistry, The Ångström Laboratory, Uppsala University, Box 538, SE-751 21 Uppsala, Sweden
| | - Neus Godino
- Centro Nacional de Microelectrónica, IMB-CNM, CSIC, Campus de la Universidad, Autónoma de Barcelona, Esfera UAB, Bellaterra-08193, Spain, Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden, and Department of Materials Chemistry, The Ångström Laboratory, Uppsala University, Box 538, SE-751 21 Uppsala, Sweden
| | - Javier del Campo
- Centro Nacional de Microelectrónica, IMB-CNM, CSIC, Campus de la Universidad, Autónoma de Barcelona, Esfera UAB, Bellaterra-08193, Spain, Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden, and Department of Materials Chemistry, The Ångström Laboratory, Uppsala University, Box 538, SE-751 21 Uppsala, Sweden
| | - Francesc Xavier Muñoz
- Centro Nacional de Microelectrónica, IMB-CNM, CSIC, Campus de la Universidad, Autónoma de Barcelona, Esfera UAB, Bellaterra-08193, Spain, Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden, and Department of Materials Chemistry, The Ångström Laboratory, Uppsala University, Box 538, SE-751 21 Uppsala, Sweden
| | - Fredrik Nikolajeff
- Centro Nacional de Microelectrónica, IMB-CNM, CSIC, Campus de la Universidad, Autónoma de Barcelona, Esfera UAB, Bellaterra-08193, Spain, Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden, and Department of Materials Chemistry, The Ångström Laboratory, Uppsala University, Box 538, SE-751 21 Uppsala, Sweden
| | - Leif Nyholm
- Centro Nacional de Microelectrónica, IMB-CNM, CSIC, Campus de la Universidad, Autónoma de Barcelona, Esfera UAB, Bellaterra-08193, Spain, Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden, and Department of Materials Chemistry, The Ångström Laboratory, Uppsala University, Box 538, SE-751 21 Uppsala, Sweden
| |
Collapse
|
33
|
Moehlenbrock MJ, Martin RS. Development of an on-chip injector for microchip-based flow analyses using laminar flow. LAB ON A CHIP 2007; 7:1589-1596. [PMID: 17960290 DOI: 10.1039/b707410g] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A new on-chip injector for microchip-based flow analyses has been designed and characterized. The microchip design utilizes separate laminar flow streams of buffer and sample that are brought into parallel contact for a distance of 300 microm. The buffer flow stream is first routed through a conventional 6-port injection valve fitted with a 5 microm i.d. sample loop. When the 6-port valve is actuated from load to inject for a given time, the on-chip buffer flow stream is constricted and the sample flow stream is pressurized into the buffer flow channel. Once the valve returns to the load state the separate laminar flow streams resume. Fluorescence detection was used to characterize the injector and it was found that 50 injections of a 100 microM fluorescein sample led to an average peak height of 174.32 +/- 2.05 AFU (RSD 1.18%) and average peak skew of 1.37 +/- 0.06. The injector was also interfaced with amperometric detection. Injections of catechol solutions ranging in concentration from 500 nM to 100 microM resulted in a linear response (sensitivity = 2.49 pA microM(-1), r(2) = 0.998) and a limit of detection of 155 nM (S/N = 3). Compared to an off-chip injection scheme, plug dilution, band broadening, and peak asymmetry are much reduced. Finally, the injection and subsequent lysis of an erythrocyte sample was demonstrated, with an injected plug of erythrocytes being lysed 5.72 +/- 0.15 s after injection into a flow stream containing sodium dodecyl sulfate (n = 10). The new injection scheme does not require complex valving mechanisms or high pressures and enables reproducible injections from a continuous sample flow stream in a manner where changes in analyte concentration can be monitored with high temporal resolution.
Collapse
Affiliation(s)
- Michael J Moehlenbrock
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103, USA
| | | |
Collapse
|