1
|
Capillary Electrophoresis Mass Spectrometry: Developments and Applications for Enantioselective Analysis from 2011–2020. Molecules 2022; 27:molecules27134126. [PMID: 35807372 PMCID: PMC9268241 DOI: 10.3390/molecules27134126] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 06/15/2022] [Accepted: 06/21/2022] [Indexed: 12/01/2022] Open
Abstract
It is now more than 25 years since the first report of enantioselective analysis by capillary electrophoresis-mass spectrometry (CE-MS) appeared. This article reviews the power of chiral CE-MS in resolving issues on the use of chiral selector incompatibility with MS and poor detectability encountered for chiral compounds by UV detection. The review begins with the general principles, requirements, and critical aspects of chiral CE-MS instrumentation. Next, the review provides a survey of MS-compatible chiral selectors (CSs) reported during the past decade, and the key achievements encountered in the time period using these CSs. Within the context of the strategies used to combine CE and MS, special attention is paid to the approaches that feature partial filling technique, counter-migration techniques, and direct use of CS, such as molecular micelles. In particular, the development and application of moving and fixed CS for EKC-MS, MEKC-MS, and CEC-MS demonstrate how various chiral compounds analyses were solved in a simple and elegant way during the 2010–2020 review period. The most noteworthy applications in the determination of chiral compounds are critically examined. The operating analytical conditions are detailed in the Tables, and the authors provide commentary on future trends of chiral separations by CE-MS.
Collapse
|
2
|
de Koster N, Clark CP, Kohler I. Past, present, and future developments in enantioselective analysis using capillary electromigration techniques. Electrophoresis 2021; 42:38-57. [PMID: 32914880 PMCID: PMC7821218 DOI: 10.1002/elps.202000151] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 08/22/2020] [Accepted: 09/08/2020] [Indexed: 12/16/2022]
Abstract
Enantioseparation of chiral products has become increasingly important in a large diversity of academic and industrial applications. The separation of chiral compounds is inherently challenging and thus requires a suitable analytical technique that can achieve high resolution and sensitivity. In this context, CE has shown remarkable results so far. Chiral CE offers an orthogonal enantioselectivity and is typically considered less costly than chromatographic techniques, since only minute amounts of chiral selectors are needed. Several CE approaches have been developed for chiral analysis, including chiral EKC and chiral CEC. Enantioseparations by EKC benefit from the wide variety of possible pseudostationary phases that can be employed. Chiral CEC, on the other hand, combines chromatographic separation principles with the bulk fluid movement of CE, benefitting from reduced band broadening as compared to pressure-driven systems. Although UV detection is conventionally used for these approaches, MS can also be considered. CE-MS represents a promising alternative due to the increased sensitivity and selectivity, enabling the chiral analysis of complex samples. The potential contamination of the MS ion source in EKC-MS can be overcome using partial-filling and counter-migration techniques. However, chiral analysis using monolithic and open-tubular CEC-MS awaits additional method validation and a dedicated commercial interface. Further efforts in chiral CE are expected toward the improvement of existing techniques, the development of novel pseudostationary phases, and establishing the use of chiral ionic liquids, molecular imprinted polymers, and metal-organic frameworks. These developments will certainly foster the adoption of CE(-MS) as a well-established technique in routine chiral analysis.
Collapse
Affiliation(s)
- Nicky de Koster
- Leiden Academic Centre for Drug Research, Division of Systems Biomedicine and PharmacologyLeiden UniversityLeidenThe Netherlands
| | - Charles P. Clark
- Leiden Academic Centre for Drug Research, Division of Systems Biomedicine and PharmacologyLeiden UniversityLeidenThe Netherlands
| | - Isabelle Kohler
- Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute for Molecular and Life SciencesVrije Universiteit AmsterdamAmsterdamThe Netherlands
| |
Collapse
|
3
|
Chiral Micellar Electrokinetic Chromatography. J Chromatogr A 2020; 1626:461383. [PMID: 32797856 DOI: 10.1016/j.chroma.2020.461383] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 06/29/2020] [Accepted: 06/30/2020] [Indexed: 12/18/2022]
Abstract
The potential of Micellar Electrokinetic Chromatography to achieve enantiomeric separations is reviewed in this article. The separation principles and the most frequently employed separation strategies to achieve chiral separations by Micellar Electrokinetic Chromatography are described. The use of chiral micellar systems alone or combined with other micellar systems or chiral selectors, as well as of mixtures of achiral micellar systems with chiral selectors is discussed together with the effect of different additives present in the separation medium. Indirect methods based on the derivatization of analytes with chiral derivatizing reagents and the use of achiral micelles are also considered. Preconcentration techniques employed to improve sensitivity and the main approaches developed to facilitate the coupling with Mass Spectrometry are included. The most recent and relevant methodologies developed by chiral Micellar Electrokinetic Chromatography and their applications in different fields are presented.
Collapse
|
4
|
Establishing repeatability and ruggedness of chiral separations in micellar electrokinetic chromatography mass spectrometry: Combined use of covalently bonded capillary column and molecular micelles. J Chromatogr A 2019; 1617:460835. [PMID: 31928773 DOI: 10.1016/j.chroma.2019.460835] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2019] [Revised: 12/24/2019] [Accepted: 12/29/2019] [Indexed: 10/25/2022]
Abstract
Although micellar electrokinetic chromatography-mass spectrometry (MEKC-MS) using bare silica capillary filled with molecular micelles is an advantageous hyphenated technique for chiral analysis, it is still in the developmental stage. This is mainly because of the lower repeatability of retention time and peak area associated with the difficulty in controlling electroosmotic flow on bare silica capillaries. Besides the lower robustness and electrospray erosion of the fused-silica capillary tip, the lifetime is limited for 10-15 runs per capillary column. We have tested a new MEKC-MS method to eradicate this problem using a covalently bonded 2-acrylamido-2-methyl-1-propane-sulfonic acid (AMPS) column filled with free floating molecular micelles, polysodium N-undecenoxy carbonyl-L-leucinate (poly-L-SUCL). Simultaneous enantiomeric separations and MS/MS detection of three β-blockers [atenolol (ATEN), metoprolol (METO) and, pindolol (PINDO)] was achieved within 25 min with improved column lifetime of at least 45-50 runs. Excellent repeatability of retention time was observed for β-blockers, as evidenced by the relative standard deviation of less than 2% and 3% for intra-capillary and inter-capillary column, respectively. The linear calibration range of both β-blockers was simultaneously established using enantiomers of PINDO as an internal standard. The limit of detection and the lower limit of quantitation were 0.2 μg/mL and 0.5 μg/mL, respectively, for both ATEN and METO. Acceptable recovery of the enantiomeric content of the commercial METO tablet (98-99.5%) and ATEN tablet (89-92.5%) were obtained with adequate system suitability for the precision of peak area (≤10% RSD) under optimum conditions. The developed MEKC-MS approach was extended, which provided broader repeatibility of chiral separation to a panel of primary, secondary and tertiary amines as well as one anionic chiral compound.
Collapse
|
5
|
GAO F, WANG XF, ZHANG B. Research and Application Progress of Micellar Electrokinetic Chromatography in Separation of Proteins. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/s1872-2040(19)61163-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
6
|
Javed S, Ahsan W. Microemulsion based chromatographic techniques: Past lessons and future directions. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2019.1584746] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Shamama Javed
- Department of Pharmaceutics, College of Pharmacy, Jazan University, Jazan, Saudi Arabia
| | - Waquar Ahsan
- Department of Pharmaceutical Chemistry, College of Pharmacy, Jazan University, Jazan, Saudi Arabia
| |
Collapse
|
7
|
Liu Y, Shamsi SA. Chiral Capillary Electrophoresis-Mass Spectrometry: Developments and Applications in the Period 2010-2015: A Review. J Chromatogr Sci 2016; 54:1771-1786. [PMID: 27371855 DOI: 10.1093/chromsci/bmw100] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Indexed: 11/14/2022]
Abstract
The sensitive detection of chiral compounds by capillary electrophoresis (CE) in biological samples remains a significant challenge and is currently considered a bottleneck in many chiral analysis projects. Chiral CE-MS can significantly improve the limit of detection and provide high sensitivity compared with chiral CE-UV. Chiral selectors such as modified cyclodextrins (CDs) and polymeric surfactants (a.k.a. molecular micelles, MoMs) in electrokinetic chromatography (EKC), micellar electrokinetic chromatography (MEKC) and capillary electrochromatography (CEC) have been developed to address the need for high sensitivity by CE-MS. However, several problems remain to be investigated to fully understand the potential of these hyphenation modes. This review provides introduction to major chiral CE-MS modes for the novice and highlights the important working principles of each mode of chiral CE-MS. Next, recent practical developments and progress in chiral CE-MS dating from January 2010 to September 2015 are described. The achievements in clinical and biomedical sciences using a variety of chiral selectors such as CDs and MoMs in EKC-MS, MEKC-MS and CEC-MS are discussed. Finally, conclusions and future prospects of CE-MS in chiral analysis are drafted.
Collapse
Affiliation(s)
- Yijin Liu
- Department of Chemistry, Georgia State University, Atlanta, GA 30303, USA
| | - Shahab A Shamsi
- Department of Chemistry, Georgia State University, Atlanta, GA 30303, USA
| |
Collapse
|
8
|
Fei ZX, Zhang M, Xie SM, Yuan LM. Capillary electrochromatographic fast enantioseparation based on a chiral metal-organic framework. Electrophoresis 2014; 35:3541-8. [PMID: 25223618 DOI: 10.1002/elps.201400227] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2014] [Revised: 09/01/2014] [Accepted: 09/01/2014] [Indexed: 11/09/2022]
Abstract
Metal-organic frameworks (MOFs) have received great attention because of their unusual properties and fascinating structures in separation sciences. However, to the best of our knowledge, there has been no attempt to utilize chiral MOFs as stationary phases in packed-CEC. Here, a chiral MOF [In3 O(obb)3 (HCO2 )(H2 O)]·solvent (4,4'-oxybisbenzoic acid) was explored as the chiral stationary phase in packed-CEC for separation of chiral compounds and isomers. The fabricated [In3 O(obb)3 (HCO2 )(H2 O)]·solvent packed capillary columns gave fast enantioseparation of (±)-hydrobenzoin, (±)-1-phenyl-1,2-ethanediol, and clenbuterol within 3 min in CEC. Besides, the baseline separations of nitrophenol isomers within 6 min were also achieved. The RSDs for the retention time of run-to-run, day-to-day, and column-to-column reproducibility were 1.51-3.63, 1.83-3.98, and 3.42-5.66%, respectively. These results demonstrate that chiral MOFs are promising for enantioseparation in CEC.
Collapse
Affiliation(s)
- Zhi-Xin Fei
- Department of Chemistry, Yunnan Normal University, Kunming, P. R. China
| | | | | | | |
Collapse
|
9
|
Sánchez-Hernández L, Guijarro-Diez M, Marina ML, Crego AL. New approaches in sensitive chiral CE. Electrophoresis 2013; 35:12-27. [DOI: 10.1002/elps.201300355] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2013] [Revised: 09/27/2013] [Accepted: 09/27/2013] [Indexed: 11/10/2022]
Affiliation(s)
- Laura Sánchez-Hernández
- Department of Analytical Chemistry; Physical Chemistry and Chemical Engineering, Faculty of Biology, Environmental Sciences and Chemistry, University of Alcalá; Alcalá de Henares Madrid Spain
| | - Miguel Guijarro-Diez
- Department of Analytical Chemistry; Physical Chemistry and Chemical Engineering, Faculty of Biology, Environmental Sciences and Chemistry, University of Alcalá; Alcalá de Henares Madrid Spain
| | - María Luisa Marina
- Department of Analytical Chemistry; Physical Chemistry and Chemical Engineering, Faculty of Biology, Environmental Sciences and Chemistry, University of Alcalá; Alcalá de Henares Madrid Spain
| | - Antonio L. Crego
- Department of Analytical Chemistry; Physical Chemistry and Chemical Engineering, Faculty of Biology, Environmental Sciences and Chemistry, University of Alcalá; Alcalá de Henares Madrid Spain
| |
Collapse
|
10
|
Wuethrich A, Haddad PR, Quirino JP. Chiral capillary electromigration techniques-mass spectrometry-hope and promise. Electrophoresis 2013; 35:2-11. [PMID: 24265218 DOI: 10.1002/elps.201300377] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2013] [Revised: 10/06/2013] [Accepted: 10/07/2013] [Indexed: 11/09/2022]
Abstract
Analytical methods for chiral compounds require a separation step prior to mass spectrometric detection. CE can separate enantiomers by the use of a chiral selector and can be hyphenated with MS. The chiral selector can be either embedded inside the capillary (electrochromatography) or added into the background solution (EKC). This review describes the fundamentals and highlights the recent developments (September 2009-May 2013) of chiral CEC and EKC with detection using MS. There were 20 research and more than 30 review papers during this period. The research efforts were driven by fundamental studies, such as the development of novel chiral selectors in electrochromatography and of advanced partial filling techniques in EKC in order to optimise separation. Other developments were in application studies, such as in food analytics and metabolomics.
Collapse
Affiliation(s)
- Alain Wuethrich
- Australian Centre for Research on Separation Science (ACROSS), School of Chemistry, University of Tasmania, Hobart, Australia
| | | | | |
Collapse
|
11
|
Tsioupi DA, Stefan-Vanstaden RI, Kapnissi-Christodoulou CP. Chiral selectors in CE: recent developments and applications. Electrophoresis 2013; 34:178-204. [PMID: 23161372 DOI: 10.1002/elps.201200239] [Citation(s) in RCA: 88] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2012] [Revised: 08/14/2012] [Accepted: 08/14/2012] [Indexed: 01/01/2023]
Abstract
This review article provides an overview of the recent advances in enantioanalysis by use of electrophoretic techniques. Due to the big number of publications in the subject mentioned above, this article is focused on chiral method developments and applications published from 2008 until 2011, and it demonstrates chiral selectors used in CE. Numerous chiral selectors have been used over the years, and these include the cyclic and the linear oligo- and polysaccharides, the branched polysaccharides, the polymeric and monomeric surfactants, the macrocyclic and other antibiotics, and the crown ethers. Different dual-selector systems are also presented in this article, and the results are compared with those obtained by use of a single chiral selector. Finally, several pharmaceutical and biomedical applications based on chiral recognition are summarized.
Collapse
|
12
|
He J, Shamsi SA. Application of polymeric surfactants in chiral micellar electrokinetic chromatography (CMEKC) and CMEKC coupled to mass spectrometry. Methods Mol Biol 2013; 970:319-348. [PMID: 23283788 DOI: 10.1007/978-1-62703-263-6_21] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The use of amino acid-based polymeric surfactants (a.k.a. molecular micelles) in chiral micellar electrokinetic chromatography (CMEKC) has been shown to be a successful separation mode for capillary electrophoresis (CE). In this mode, chiral compounds can be enantioseparated with high efficiency, high chiral selectivity, and versatility. This chapter describes the state-of-the art studies published in the past 5 years in CMEKC using polymeric surfactants. Recent trends in the compatibility of chiral polymeric surfactants with mass spectrometric (MS) detection suggest that this type of chiral selector may be the most promising ones for chiral CE-MS applications. The synthesis of new anionic and cationic MS-compatible polymeric surfactants and their utility in CMEKC and CMEKC-MS are demonstrated. Examples of how to run a typical CMEKC-MS experiment using univariate and multivariate optimization of CMEKC and MS parameters are discussed.
Collapse
Affiliation(s)
- Jun He
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA, USA
| | | |
Collapse
|
13
|
Silva M. Micellar electrokinetic chromatography: A review of methodological and instrumental innovations focusing on practical aspects. Electrophoresis 2012; 34:141-58. [DOI: 10.1002/elps.201200349] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 07/25/2012] [Accepted: 07/25/2012] [Indexed: 12/20/2022]
Affiliation(s)
- Manuel Silva
- Department of Analytical Chemistry, Rabanales Campus; University of Cordoba; Cordoba; Spain
| |
Collapse
|
14
|
Development of a chiral micellar electrokinetic chromatography-tandem mass spectrometry assay for simultaneous analysis of warfarin and hydroxywarfarin metabolites: application to the analysis of patients serum samples. J Chromatogr A 2012; 1271:207-16. [PMID: 23246089 DOI: 10.1016/j.chroma.2012.11.046] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2012] [Revised: 11/14/2012] [Accepted: 11/19/2012] [Indexed: 11/22/2022]
Abstract
The enantioseparation of warfarin (WAR) along with the five positional and optical isomers is challenging because of the difficulty to simultaneously separate and quantitate these chiral compounds. Currently, no effective chiral CE-MS methods exist for the simultaneous enantioseparation of WAR and all its hydroxylated metabolites in a single run. Polymeric surfactants (aka. molecular micelles) are particularly compatible with micellar electrokinetic chromatography-mass spectrometry (MEKC-MS) because they have a wider elution window for enantioseparation and do not interfere with the MS detection of chiral drugs. Using polysodium N-undecenoyl-L,L-leucylvalinate (poly-L,L-SULV) as a chiral pseudophase in MEKC-MS baseline separation of WAR, its five metabolites along with the internal standard was obtained in 45 min. This is in comparison to 100 min required for separation of the same mixture with packed column CEC-MS using a vancomycin chiral stationary phase. Serum samples were extracted with mixed-mode anion-exchange (MAX) cartridge with recoveries of greater than 85.2% for all WAR and hydroxywarfarin (OH-WAR) metabolites. Utilizing the tandem MS and multiple reaction monitoring mode, the MEKC-MS/MS method was used to simultaneously generate calibration curves over a concentration range from 2 to 5000 ng/mL for R- and S-warfarin, 5 to 1000 ng/mL for R- and S-6-, 7-, 8- and 10-OH-WAR and 10 to 1000 ng/mL for R and S-4'-OH-WAR. For the first time, the limits of detection and quantitation for most WAR metabolites by MEKC-MS/MS were found to be at levels of 2 and 5 ng/mL, respectively. The method was successfully applied for the first time to analyze WAR and its metabolites in plasma samples of 55 patients undergoing WAR therapy, demonstrating the potential of chiral MEKC-MS/MS method to accurately quantitate with high sensitivity.
Collapse
|
15
|
Abstract
AbstractEnantiomers (stereoisomers) can exhibit substantially different properties if present in chiral environments. Since chirality is a basic property of nature, the different behaviors of the individual enantiomers must be carefully studied and properly treated. Therefore, enantioselective separations are a very important part of separation science. To achieve the separation of enantiomers, an enantioselective environment must be created by the addition of a chiral selector to the separation system. Many chiral selectors have been designed and used in various fields, such as the analyses of drugs, food constituents and agrochemicals. The most popular have become the chiral selectors and/or chiral stationary phases that are of general use, i.e., are applicable in various separation systems and allow for chiral separation of structurally different compounds. This review covers the most important chiral selectors / chiral stationary phases described and applied in high performance liquid chromatography and capillary electrophoresis during the period of the last three years (2008–2011).
Collapse
|
16
|
Affiliation(s)
- Matthew Geiger
- University of Minnesota, Department of Chemistry, 207
Pleasant Street South East, Minneapolis, Minnesota 55455, United States
| | - Amy L. Hogerton
- University of Minnesota, Department of Chemistry, 207
Pleasant Street South East, Minneapolis, Minnesota 55455, United States
| | - Michael T. Bowser
- University of Minnesota, Department of Chemistry, 207
Pleasant Street South East, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
17
|
Affiliation(s)
- Timothy J. Ward
- Millsaps College, 1701 N. State Street, Box 150306, Jackson, Mississippi 39210, United States
| | - Karen D. Ward
- Millsaps College, 1701 N. State Street, Box 150306, Jackson, Mississippi 39210, United States
| |
Collapse
|