1
|
Cancho-Gonzalez S, Ferguson P, Herniman JM, Langley GJ. Dispersity determination of poly(ethylene glycol)s using supercritical fluid chromatography-mass spectrometry and different mass analysers. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2024; 38:e9765. [PMID: 38742369 DOI: 10.1002/rcm.9765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 04/15/2024] [Accepted: 04/18/2024] [Indexed: 05/16/2024]
Abstract
RATIONALE Dispersity values are considered critical quality attributes for the quality control of poly(ethylene glycol) formulations due to the direct impact on drug performance. However, when these polymers are analysed using mass spectrometry, the design of the mass analyser can impact the oligomer response and affect the obtained dispersity values, so further understanding is needed. METHODS The deconvoluted electrospray ionisation mass spectra of poly(ethylene glycol)s obtained using supercritical fluid chromatography (SFC) hyphenated to different mass analysers were compared, and visualisation diagrams were used to understand the differences in the dispersity value calculations. Five calibration approaches based on a surrogate single oligomer that represents the whole distribution, or the whole distribution itself, for response selection, were used to evaluate ionisation efficiency prior to quantitation. The impact of using an internal standard (ISTD) on the expanded uncertainty was also assessed. RESULTS Although there were challenges related to the resolution of multiply charged species when low-resolution instruments were used, similar quantitation capabilities were obtained to those when high-resolution mass analysers were used. Evaluation of approaches using a surrogate oligomer or the whole distribution suggested the independence of both approaches and a constant ionisation efficiency across the oligomer chain length. The higher degree of chromatographic resolution of SFC allowed incorporating a monodispersed ISTD to improve the accuracy and precision of the method. CONCLUSIONS The use of low resolution mass analysers was sufficient to provide accurate and precise dispersity values; however, higher resolution instruments were recommended for characterisation due to the improved mass resolution of ions. The introduction of a monodispersed ISTD improved precision without compromising the calculated dispersity value due to the lack of analyte suppression.
Collapse
Affiliation(s)
- Sergio Cancho-Gonzalez
- Faculty of Engineering and Physical Sciences, School of Chemistry, University of Southampton, Southampton, UK
| | - Paul Ferguson
- New Modalities and Parenteral Development, Pharmaceutical Technology and Development, Operations, AstraZeneca, Macclesfield, UK
| | - Julie M Herniman
- Faculty of Engineering and Physical Sciences, School of Chemistry, University of Southampton, Southampton, UK
| | - G John Langley
- Faculty of Engineering and Physical Sciences, School of Chemistry, University of Southampton, Southampton, UK
| |
Collapse
|
2
|
Studzińska S, Szymarek J, Mazurkiewicz-Bełdzińska M. Improvement of serum sample preparation and chromatographic analysis of nusinersen used for the treatment of spinal muscular atrophy. Talanta 2024; 267:125173. [PMID: 37690419 DOI: 10.1016/j.talanta.2023.125173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 08/29/2023] [Accepted: 09/05/2023] [Indexed: 09/12/2023]
Abstract
The present investigation showed that each of the three different liquid chromatography modes may be successfully used for the qualitative analysis of nusinersen metabolites in a patient's serum sample extract. However, the smallest number was detected by the hydrophilic interaction liquid chromatography. Furthermore, the response of the mass spectrometry is several times greater for ion pair chromatography compared to reversed-phase one. Various extraction methods were applied for the extraction of nusinersen metabolites from serum. Silica with bonded capture strand for hybridization was applied, as well as silica modified with amino and carboxyl groups for dispersive solid phase extraction. The hybridization allows selective extraction of nusinersen analogs, however, it fails in extraction of short metabolites. On the contrary, the efficiency of weak ion exchange-based extraction was high, even in the case of the direct extraction of nusinersen metabolites from diluted serum samples without a protein removal step. The new material is a great alternative to liquid-liquid extraction and hybridization for the isolation of nusinersen metabolites from the serum of patients with spinal muscular atrophy (SMA). It is a very simple method that uses a low concentration of organic salt and desorption occurs after changing its pH. Such complex studies were performed for the first time for nusinersen metabolites extracted from the serum of SMA patients treated with Spinraza.
Collapse
Affiliation(s)
- Sylwia Studzińska
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin Str., PL-87-100 Toruń, Poland; Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University in Toruń, 4 Wilenska St., 87-100, Toruń, Poland.
| | - Jakub Szymarek
- Department of Developmental Neurology, Medical University of Gdansk, 7 Dębinki Str., PL-80-952, Gdańsk, Poland
| | | |
Collapse
|
3
|
Kenderdine T, Fabris D. The multifaceted roles of mass spectrometric analysis in nucleic acids drug discovery and development. MASS SPECTROMETRY REVIEWS 2023; 42:1332-1357. [PMID: 34939674 PMCID: PMC9218015 DOI: 10.1002/mas.21766] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 09/23/2021] [Accepted: 11/22/2021] [Indexed: 06/07/2023]
Abstract
The deceptively simple concepts of mass determination and fragment analysis are the basis for the application of mass spectrometry (MS) to a boundless range of analytes, including fundamental components and polymeric forms of nucleic acids (NAs). This platform affords the intrinsic ability to observe first-hand the effects of NA-active drugs on the chemical structure, composition, and conformation of their targets, which might affect their ability to interact with cognate NAs, proteins, and other biomolecules present in a natural environment. The possibility of interfacing with high-performance separation techniques represents a multiplying factor that extends these capabilities to cover complex sample mixtures obtained from organisms that were exposed to NA-active drugs. This report provides a brief overview of these capabilities in the context of the analysis of the products of NA-drug activity and NA therapeutics. The selected examples offer proof-of-principle of the applicability of this platform to all phases of the journey undertaken by any successful NA drug from laboratory to bedside, and provide the rationale for its rapid expansion outside traditional laboratory settings in support to ever growing manufacturing operations.
Collapse
Affiliation(s)
| | - Dan Fabris
- Department of Chemistry, University of Connecticut
| |
Collapse
|
4
|
Vanhinsbergh C, Hook EC, Oxby N, Dickman MJ. Optimization of orthogonal separations for the analysis of oligonucleotides using 2D-LC. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1227:123812. [PMID: 37454408 DOI: 10.1016/j.jchromb.2023.123812] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/28/2023] [Accepted: 06/30/2023] [Indexed: 07/18/2023]
Abstract
Oligonucleotides are commonly analysed using one dimensional chromatography (1D-LC) to resolve and characterise manufacturing impurities, structural isomers and (in respect to emerging oligonucleotide therapeutics) drug substance and drug product. Due to low selectivity and co-elution of closely related oligonucleotides using 1D-LC, analyte resolution is challenged. This leads to the requirement for improved analytical methods. Multidimensional chromatography has demonstrated utility in a range of applications as it increases peak capacity using orthogonal separations, however there are limited studies demonstrating the 2D-LC analysis of closely related oligonucleotides. In this study we optimised OGN size and sequence based separations using a variety of 1D-LC methods and coupled these orthogonal modes of chromatography within a 2D-LC workflow. Theoretical 2D-LC workflows were evaluated for optimal orthogonality using the minimum convex hull metric. The most orthogonal workflow identified in this study was ion-pair reversed phase using tributylammonium acetate (IP-RP-TBuAA) coupled with strong anion exchange in conjunction with sodium perchlorate (SAX-NaClO4) at high mobile phase pH. We developed a heart-cut (IP-RP-TBuAA)-(SAX-NaClO4) 2D-LC method for analysis of closely related size and sequence variant OGNs and OGN manufacturing impurities. The 2D-LC method resulted in an increased orthogonality and a reduction in co-elution (or close elution). Application of a UV based reference mapping strategy in conjunction with the 2D-LC method demonstrated a reduction in analytical complexity by reducing the reliance on mass based detection methods.
Collapse
Affiliation(s)
- Christina Vanhinsbergh
- Department of Chemical and Biological Engineering, Mappin Street, University of Sheffield, S1 3JD, UK
| | - Elliot C Hook
- GlaxoSmithKline, GSK Medicines Research Centre, Gunnels Wood Road, Stevenage, Herts SG1 2NY, UK
| | - Nicola Oxby
- GlaxoSmithKline, GSK Medicines Research Centre, Gunnels Wood Road, Stevenage, Herts SG1 2NY, UK
| | - Mark J Dickman
- Department of Chemical and Biological Engineering, Mappin Street, University of Sheffield, S1 3JD, UK.
| |
Collapse
|
5
|
Lardeux H, Goyon A, Zhang K, Nguyen JM, Lauber MA, Guillarme D, D'Atri V. The impact of low adsorption surfaces for the analysis of DNA and RNA oligonucleotides. J Chromatogr A 2022; 1677:463324. [PMID: 35858489 DOI: 10.1016/j.chroma.2022.463324] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 07/07/2022] [Accepted: 07/08/2022] [Indexed: 12/20/2022]
Abstract
As interest in oligonucleotide (ON) therapeutics is increasing, there is a need to develop suitable analytical methods able to properly analyze those molecules. However, an issue exists in the adsorption of ONs on different parts of the instrumentation during their analysis. The goal of the present paper was to comprehensively evaluate various types of bioinert materials used in ion-pairing reversed-phase (IP-RPLC) and hydrophilic interaction chromatography (HILIC) to mitigate this issue for 15- to 100-mer DNA and RNA oligonucleotides. The whole sample flow path was considered under both conditions, including chromatographic columns, ultra-high-performance liquid chromatography (UHPLC) system, and ultraviolet (UV) flow cell. It was found that a negligible amount of non-specific adsorption might be attributable to the chromatographic instrumentation. However, the flow cell of a detector should be carefully subjected to sample-based conditioning, as the material used in the UV flow cell was found to significantly impact the peak shapes of the largest ONs (60- to 100-mer). Most importantly, we found that the choice of column hardware had the most significant impact on the extent of non-specific adsorption. Depending on the material used for the column walls and frits, adsorption can be more or less pronounced. It was proved that any type of bioinert RPLC/HILIC column hardware offered some clear benefits in terms of adsorption in comparison to their stainless-steel counterparts. Finally, the evaluation of a large set of ONs was performed, including a DNA duplex and DNA or RNA ONs having different base composition, furanose sugar, and modifications occurring at the phosphate linkage or at the sugar moiety. This work represents an important advance in understanding the overall ON adsorption, and it helps to define the best combination of materials when analyzing a wide range of unmodified and modified 20-mer DNA and RNA ONs.
Collapse
Affiliation(s)
- Honorine Lardeux
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland
| | - Alexandre Goyon
- Small Molecule Pharmaceutical Sciences, Genentech Inc., DNA Way, South San Francisco, CA 94080, USA
| | - Kelly Zhang
- Small Molecule Pharmaceutical Sciences, Genentech Inc., DNA Way, South San Francisco, CA 94080, USA
| | | | | | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland
| | - Valentina D'Atri
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland.
| |
Collapse
|
6
|
Donegan M, Nguyen JM, Gilar M. Effect of ion-pairing reagent hydrophobicity on liquid chromatography and mass spectrometry analysis of oligonucleotides. J Chromatogr A 2022; 1666:462860. [PMID: 35123169 DOI: 10.1016/j.chroma.2022.462860] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/19/2022] [Accepted: 01/25/2022] [Indexed: 10/19/2022]
Abstract
We performed a systematic study of thirteen alkylamines used as ion-pairing reagents for ion-pair reversed-phase liquid chromatography (IP RP LC) separations of oligonucleotides on a C18 column. We proposed a method to classify the hydrophobicity of alkylamines by their retention in RP LC. The IP reagent hydrophobicity correlated with the retention and resolution of oligonucleotides in the corresponding IP mobile phases. The baseline resolution was achieved up to 30 mer for hydrophilic, or up to 50 mer for hydrophobic IP reagents. Hydrophobic alkylamines permitted useful oligonucleotide separations at relatively low buffer concentrations, such as 5-10 mM alkylamine-acetate IP systems. These buffers were compatible with mass spectrometry detection, however, replacement of acetic acid with hexafluoroisopropanol in the mobile phase improved the MS signal by 2-3 orders of magnitude. Experiments with native and chemically modified oligonucleotides highlighted the mixed-mode nature of IP RP LC. When using hydrophobic IP reagents, the ionic retention mechanism of oligonucleotides is enhanced while hydrophobic retention is diminished.
Collapse
Affiliation(s)
| | | | - Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA.
| |
Collapse
|
7
|
Guimaraes GJ, Bartlett MG. The critical role of mobile phase pH in the performance of oligonucleotide ion-pair liquid chromatography-mass spectrometry methods. Future Sci OA 2021; 7:FSO753. [PMID: 34840810 PMCID: PMC8610006 DOI: 10.2144/fsoa-2021-0084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 09/29/2021] [Indexed: 11/24/2022] Open
Affiliation(s)
- Guilherme J Guimaraes
- Department of Pharmaceutical & Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, GA, USA
| | - Michael G Bartlett
- Department of Pharmaceutical & Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, GA, USA
| |
Collapse
|
8
|
Largy E, König A, Ghosh A, Ghosh D, Benabou S, Rosu F, Gabelica V. Mass Spectrometry of Nucleic Acid Noncovalent Complexes. Chem Rev 2021; 122:7720-7839. [PMID: 34587741 DOI: 10.1021/acs.chemrev.1c00386] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Nucleic acids have been among the first targets for antitumor drugs and antibiotics. With the unveiling of new biological roles in regulation of gene expression, specific DNA and RNA structures have become very attractive targets, especially when the corresponding proteins are undruggable. Biophysical assays to assess target structure as well as ligand binding stoichiometry, affinity, specificity, and binding modes are part of the drug development process. Mass spectrometry offers unique advantages as a biophysical method owing to its ability to distinguish each stoichiometry present in a mixture. In addition, advanced mass spectrometry approaches (reactive probing, fragmentation techniques, ion mobility spectrometry, ion spectroscopy) provide more detailed information on the complexes. Here, we review the fundamentals of mass spectrometry and all its particularities when studying noncovalent nucleic acid structures, and then review what has been learned thanks to mass spectrometry on nucleic acid structures, self-assemblies (e.g., duplexes or G-quadruplexes), and their complexes with ligands.
Collapse
Affiliation(s)
- Eric Largy
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Alexander König
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Anirban Ghosh
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Debasmita Ghosh
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Sanae Benabou
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Frédéric Rosu
- Univ. Bordeaux, CNRS, INSERM, IECB, UMS 3033, F-33600 Pessac, France
| | - Valérie Gabelica
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| |
Collapse
|
9
|
Sutton JM, Kim J, El Zahar NM, Bartlett MG. BIOANALYSIS AND BIOTRANSFORMATION OF OLIGONUCLEOTIDE THERAPEUTICS BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY. MASS SPECTROMETRY REVIEWS 2021; 40:334-358. [PMID: 32588492 DOI: 10.1002/mas.21641] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 05/05/2020] [Accepted: 05/28/2020] [Indexed: 06/11/2023]
Abstract
Since 2016, eight new oligonucleotide therapies have been approved which has led to increased interest in oligonucleotide analysis. There is a particular need for powerful bioanalytical tools to study the metabolism and biotransformation of these molecules. This review provides the background on the biological basis of these molecules as currently used in therapies. The article also reviews the current state of analytical methodology including state of the art sample preparation techniques, liquid chromatography-mass spectrometry methods, and the current limits of detection/quantitation. Finally, the article summarizes the challenges in oligonucleotide bioanalysis and provides future perspectives for this emerging field. © 2020 John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- James Michael Sutton
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
| | - Jaeah Kim
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
| | - Noha M El Zahar
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Organization of African Unity Street, Cairo, 11566, Egypt
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
| |
Collapse
|
10
|
Evaluating the interplay among stationary phases/ion-pairing reagents/sequences for liquid chromatography mass spectrometry analysis of oligonucleotides. Anal Biochem 2021; 625:114194. [PMID: 33910045 DOI: 10.1016/j.ab.2021.114194] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 03/05/2021] [Accepted: 03/27/2021] [Indexed: 11/22/2022]
Abstract
The correlation among stationary phases, ion-pairing reagents (IPR) and sequences for ion-pair reversed-phase liquid chromatography mass spectrometry (IP-RP LC-MS) analysis of oligonucleotide (ODN) remains unclear. The present study aimed to evaluate such correlation using particle-packed C18 columns in order to search for the optimal combination among them. Five C18 columns packed with core-shell silica, polymer, porous silica and hybrid particles, respectively, were evaluated for the analysis of synthetic and chemically modified ODNs with six different IPRs. Our results showed that silica-based porous particles, compared to other particles, retained ODN the strongest no matter which IPR was used. Meanwhile, among the six IPRs hexylamine (HA) produced the longest retention for all ODNs, regardless of the types of C18 particles. For the separation of ODNs, C18 columns performed similarly under identical LC conditions. However, the separation ability of C18 columns is highly dependent on the type of IPR and ODN sequences. Moreover, the type of particles has little impact on the signals of ODNs for the majority of synthetic sequences, but such impact could be dramatic for chemically modified sequences. On the other hand, both the type of IPR and ODN sequence have a significant effect on MS signals for synthetic and chemically modified ODNs.
Collapse
|
11
|
Pourshahian S. THERAPEUTIC OLIGONUCLEOTIDES, IMPURITIES, DEGRADANTS, AND THEIR CHARACTERIZATION BY MASS SPECTROMETRY. MASS SPECTROMETRY REVIEWS 2021; 40:75-109. [PMID: 31840864 DOI: 10.1002/mas.21615] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Oligonucleotides are an emerging class of drugs that are manufactured by solid-phase synthesis. As a chemical class, they have unique product-related impurities and degradants, characterization of which is an essential step in drug development. The synthesis cycle, impurities produced during the synthesis and degradation products are presented and discussed. The use of liquid chromatography combined with mass spectrometry for characterization and quantification of product-related impurities and degradants is reviewed. In addition, sequence determination of oligonucleotides by gas-phase fragmentation and indirect mass spectrometric methods is discussed. © 2019 John Wiley & Sons Ltd. Mass Spec Rev.
Collapse
Affiliation(s)
- Soheil Pourshahian
- Janssen Pharmaceutical Companies of Johnson & Johnson, South San Francisco, CA, 94080
| |
Collapse
|
12
|
Roussis SG, Rodriguez AA, Rentel C. Determination of individual oligonucleotide impurities by small amine ion pair-RP HPLC MS and MS/MS: n - 1 impurities. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1169:122611. [PMID: 33706187 DOI: 10.1016/j.jchromb.2021.122611] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 02/09/2021] [Accepted: 02/18/2021] [Indexed: 12/01/2022]
Abstract
Ion pair-reversed phase (IP-RP) HPLC is one of the most widely used methods for the analysis of oligonucleotide impurities. The method is compatible with mass spectrometry and has been used to guide the development of improved synthesis and purification approaches. The ability to detect and characterize impurities depends on the reagents and the IP buffer system employed, as each can directly affect the degree of chromatographic separation and the sensitivity of detection by MS. Previous work in our laboratory has shown that small alkyl amines are suitable IP reagents for the analysis of impurities in phosphate diester oligonucleotides and can be used to differentiate among individual members of composite impurity families. The addition of an alkyl acid often further enhances peak separation, but at the detriment of ion signal. An improved method with increased chromatographic performance and sensitivity of detection is presented here. Improvements were mainly realized through the use of lower concentrations of small alkyl amine (i.e., 5 mM) and acid (0.5 mM) IP reagents, and ammonium bicarbonate (20 mM) as a buffer. The improved capabilities of the new method are demonstrated by separation of the individual components of the composite n - 1 impurity in a set of four production-scale batches of a single oligonucleotide. Addition of the alkyl acid resulted in resolution of most individual n - 1 impurities. The observed enhanced sensitivity of detection allowed multiple reaction monitoring (MRM) experiments, which were used to differentiate among unresolved impurities.
Collapse
Affiliation(s)
| | | | - Claus Rentel
- Ionis Pharmaceuticals, Carlsbad, CA 92010, United States
| |
Collapse
|
13
|
Sutton JM, El Zahar NM, Bartlett MG. Oligonucleotide Anion Adduct Formation Using Negative Ion Electrospray Ion-Mobility Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:497-508. [PMID: 33476148 DOI: 10.1021/jasms.0c00380] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Improving the mobile phase of electrospray oligonucleotides has been a major focus in the field of oligonucleotides. These improved mobile phases should reduce the charge state envelope of oligonucleotides coupled with electrospray ionization, which is key to reducing spectral complexity and increasing sensitivity. Traditional mobile phase compositions with fluorinated alcohol and alkylamine, like hexafluoroisopropanol (HFIP) and triethylamine (TEA), have a large amount of cationic adduction and many charge states. Utilizing different fluorinated alcohol and alkylamine combinations, like nonafluoro-tert-butyl alcohol (NFTB) and octylamine (OA), can selectively reduce the charge states analyzed. Other classes of biomolecules have been analyzed with anionic salts to stabilize complexes, increase the molecular peak detection, and even provide unique structural information about these molecules; however, there have been no studies using anionic salts with oligonucleotides. Our experiments systematically study the stability and binding of ammonium anionic salt. We show that anions selectively bind low charge states of these oligonucleotides. Ion-mobility measurements are made to determine the collision cross section (CCS) of these oligonucleotides with anion adduction. We utilize both a nucleic acid exact hard sphere simulation (EHSS) calibration and a protein calibration. We are able to show that NFTB/OA is a good choice for the study of oligonucleotides with reduced charge states for the binding of anionic salts and the determination of CCS using ion mobility.
Collapse
Affiliation(s)
- J Michael Sutton
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 West Green Street, Athens, Georgia 30602-2352, United States
| | - Noha M El Zahar
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 West Green Street, Athens, Georgia 30602-2352, United States
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Ain Shams University, Organization of African Unity Street, Abassia, Cairo 11566, Egypt
- Medicinal Chemistry Department, Faculty of Pharmacy, King Salman International University, Ras-Sedr, South Sinai Governorate 46612, Egypt
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 West Green Street, Athens, Georgia 30602-2352, United States
| |
Collapse
|
14
|
Santos IC, Brodbelt JS. Recent developments in the characterization of nucleic acids by liquid chromatography, capillary electrophoresis, ion mobility, and mass spectrometry (2010-2020). J Sep Sci 2021; 44:340-372. [PMID: 32974962 PMCID: PMC8378248 DOI: 10.1002/jssc.202000833] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 09/18/2020] [Accepted: 09/21/2020] [Indexed: 12/25/2022]
Abstract
The development of new strategies for the analysis of nucleic acids has gained momentum due to the increased interest in using these biomolecules as drugs or drug targets. The application of new mass spectrometry ion activation techniques and the optimization of separation methods including liquid chromatography, capillary electrophoresis, and ion mobility have allowed more detailed characterization of nucleic acids and oligonucleotide therapeutics including confirmation of sequence, localization of modifications and interaction sites, and structural analysis as well as identification of failed sequences and degradation products. This review will cover tandem mass spectrometry methods as well as the recent developments in liquid chromatography, capillary electrophoresis, and ion mobility coupled to mass spectrometry for the analysis of nucleic acids and oligonucleotides.
Collapse
Affiliation(s)
- Inês C Santos
- Department of Chemistry, University of Texas at Austin, Austin, Texas, USA
| | | |
Collapse
|
15
|
Sutton JM, Bartlett MG. Modeling cationic adduction of oligonucleotides using electrospray desorption ionization. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8696. [PMID: 31834644 DOI: 10.1002/rcm.8696] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 12/06/2019] [Accepted: 12/07/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE Cationic adduction causes poor sensitivity and increases spectral complexity during mass spectral analysis of oligonucleotides and alkylamines are used to reduce this adduction. It is unclear the effect of the physiochemical properties of the alkylamines on the reduction of the cationic adduction. METHODS All samples were directly infused into a Synapt G2 HDMS quadrupole time-of-flight (TOF) hybrid mass spectrometer in negative ion electrospray ionization mode through the native built-in fluidics system. The infusion flow rate was set to 50 μL/min. The TOFMS tuning parameters were as follows: capillary voltage -2.0 kV, cone voltage 25 V, extraction cone voltage 2 V, source temperature 125°C, desolvation temperature 450°C, cone gas flow rate 0 L/h, and desolvation gas (nitrogen) flow rate 1000 L/h. RESULTS A quantitative model was created to predict the optimized alkylamine for MS analysis, while a qualitative model was generated to explain the most important physiochemical properties: proton affinity (13.83%), gas-phase basicity (11.79%), pKa (11.47%), boiling point (10.73%), MW (10.3%), Henry's Law Constant (9.56%), and partition coefficient (logP) (9.44%). The quantitative model was applied to RNA (microRNA) and a phosphorothioate and predicts the trend of cationic adduction. CONCLUSIONS Two models are described to understand the physiochemical properties that contribute to the adduction and to provide users a quick mathematical tool to predict the best choice of alkylamine to lower cationic adduction and decrease spectral complexity while enhancing sensitivity.
Collapse
Affiliation(s)
- J Michael Sutton
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352, USA
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352, USA
| |
Collapse
|
16
|
Li C, Attanayake K, Valentine SJ, Li P. Facile Improvement of Negative Ion Mode Electrospray Ionization Using Capillary Vibrating Sharp-Edge Spray Ionization. Anal Chem 2020; 92:2492-2502. [PMID: 31940176 PMCID: PMC7318871 DOI: 10.1021/acs.analchem.9b03983] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Electrospray ionization (ESI) is often affected by corona discharge when spraying 100% aqueous solutions as the voltage that induces discharge can be well below the onset voltage of ESI. As a result, it is especially challenging to perform native mass spectrometry in negative ion mode where 100% aqueous solution is preferred. Here we report a simple instrumentation method to improve the performance of ESI in negative ion mode based on capillary vibrating sharp-edge spray ionization. By attaching a fused silica capillary emitter to a vibrating glass slide, improved signal quality is achieved for various analytes in aqueous solutions over applying ESI alone. Compared to commercial ESI sources using nebulization gas to reduce discharge, 10-100-fold enhancement in signal intensity and 3-10-fold improvement in S/N are achieved for various kinds of molecules including DNA, peptides, proteins, and oligosaccharides. Finally, the new method demonstrates utility for native mass spectrometry analysis of proteins and G-quadruplex DNA. The present method is expected to have great potential to be adopted by the scientific community because of its improved analytical performance, simplicity, and low cost.
Collapse
Affiliation(s)
- Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Kushani Attanayake
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Stephen J. Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| |
Collapse
|
17
|
Elzahar NM, Magdy N, El-Kosasy AM, Bartlett MG. Degradation product characterization of therapeutic oligonucleotides using liquid chromatography mass spectrometry. Anal Bioanal Chem 2018; 410:3375-3384. [PMID: 29654340 DOI: 10.1007/s00216-018-1032-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 03/05/2018] [Accepted: 03/19/2018] [Indexed: 12/23/2022]
Abstract
Synthetic antisense phosphorothioate oligonucleotides (PS) have undergone rapid development as novel therapeutic agents. The increasing significance of this class of drugs requires significant investment in the development of quality control methods. The determination of the many degradation pathways of such complex molecules presents a significant challenge. However, an understanding of the potential impurities that may arise is necessary to continue to advance these powerful new therapeutics. In this study, four different antisense oligonucleotides representing several generations of oligonucleotide therapeutic agents were evaluated under various stress conditions (pH, thermal, and oxidative stress) using ion-pairing reversed-phase liquid chromatography tandem mass spectrometry (IP-RPLC-MS/MS) to provide in-depth characterization and identification of the degradation products. The oligonucleotide samples were stressed under different pH values at 45 and 90 °C. The main degradation products were observed to be losses of nucleotide moieties from the 3'- and 5'-terminus, depurination, formation of terminal phosphorothioates, and production of ribose, ribophosphorothioates (Rp), and phosphoribophosphorothioates (pRp). Moreover, the effects of different concentrations of hydrogen peroxide were studied resulting in primarily extensive desulfurization and subsequent oxidation of the phosphorothioate linkage to produce the corresponding phosphodiester. The reaction kinetics for the degradation of the oligonucleotides under the different stress conditions were studied and were found to follow pseudo-first-order kinetics. Differences in rates exist even for oligonucleotides of similar length but consisting of different sequences. Graphical abstract Identification of degradation products across several generations of oligonucleotide therapeutics using LC-MS.
Collapse
Affiliation(s)
- N M Elzahar
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Organization of African Unity Street, Abassia, Cairo, 11566, Egypt.,Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352, USA
| | - N Magdy
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Organization of African Unity Street, Abassia, Cairo, 11566, Egypt
| | - Amira M El-Kosasy
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Organization of African Unity Street, Abassia, Cairo, 11566, Egypt
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352, USA.
| |
Collapse
|
18
|
McClory PJ, Håkansson K. Corona Discharge Suppression in Negative Ion Mode Nanoelectrospray Ionization via Trifluoroethanol Addition. Anal Chem 2017; 89:10188-10193. [PMID: 28841300 PMCID: PMC5642034 DOI: 10.1021/acs.analchem.7b01225] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Negative ion mode nanoelectrospray ionization (nESI) is often utilized to analyze acidic compounds, from small molecules to proteins, with mass spectrometry (MS). Under high aqueous solvent conditions, corona discharge is commonly observed at emitter tips, resulting in low ion abundances and reduced nESI needle lifetimes. We have successfully reduced corona discharge in negative ion mode by trace addition of trifluoroethanol (TFE) to aqueous samples. The addition of as little as 0.2% TFE increases aqueous spray stability not only in nESI direct infusion, but also in nanoflow liquid chromatography (nLC)/MS experiments. Negative ion mode spray stability with 0.2% TFE is approximately 6× higher than for strictly aqueous samples. Upon addition of 0.2% TFE to the mobile phase of nLC/MS experiments, tryptic peptide identifications increased from 93 to 111 peptides, resulting in an average protein sequence coverage increase of 18%.
Collapse
Affiliation(s)
- Phillip J. McClory
- Department of Chemistry, University of Michigan, 930 North University Ave., Ann Arbor, MI 48109-1055
| | - Kristina Håkansson
- Department of Chemistry, University of Michigan, 930 North University Ave., Ann Arbor, MI 48109-1055
| |
Collapse
|
19
|
Basiri B, Murph MM, Bartlett MG. Assessing the Interplay between the Physicochemical Parameters of Ion-Pairing Reagents and the Analyte Sequence on the Electrospray Desorption Process for Oligonucleotides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1647-1656. [PMID: 28405940 PMCID: PMC5569388 DOI: 10.1007/s13361-017-1671-6] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Revised: 03/10/2017] [Accepted: 03/20/2017] [Indexed: 05/25/2023]
Abstract
Alkylamines are widely used as ion-pairing agents during LC-MS of oligonucleotides. In addition to a better chromatographic separation, they also assist with the desorption of oligonucleotide ions into the gas phase, cause charge state reduction, and decrease cation adduction. However, the choice of such ion-pairing agents has considerable influence on the MS signal intensity of oligonucleotides as they can also cause significant ion suppression. Interestingly, optimal ion-pairing agents should be selected on a case by case basis as their choice is strongly influenced by the sequence of the oligonucleotide under investigation. Despite imposing major practical difficulties to analytical method development, such a highly variable system that responds very strongly to the nuances of the electrospray composition provides an excellent opportunity for a fundamental study of the electrospray ionization process. Our investigations using this system quantitatively revealed the major factors that influenced the ESI ionization efficiency of oligonucleotides. Parameters such as boiling point, proton affinity, partition coefficient, water solubility, and Henry's law constants for the ion-pairing reagents and the hydrophobic thymine content of the oligonucleotides were found to be the most significant contributors. Identification of these parameters also allowed for the development of a statistical predictive algorithm that can assist with the choice of an optimum IP agent for each particular oligonucleotide sequence. We believe that research in the field of oligonucleotide bioanalysis will significantly benefit from this algorithm (included in Supplementary Material) as it advocates for the use of lesser-known but more suitable ion-pair alternatives to TEA for many oligonucleotide sequences. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Babak Basiri
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA
| | - Mandi M Murph
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA.
| |
Collapse
|
20
|
Basiri B, van Hattum H, van Dongen WD, Murph MM, Bartlett MG. The Role of Fluorinated Alcohols as Mobile Phase Modifiers for LC-MS Analysis of Oligonucleotides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:190-199. [PMID: 27644940 PMCID: PMC5500909 DOI: 10.1007/s13361-016-1500-3] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 08/30/2016] [Accepted: 08/31/2016] [Indexed: 06/06/2023]
Abstract
Hexafluoroisopropanol (HFIP) has been widely used as an acidic modifier for mobile phases for liquid chromatography-mass spectrometry (LC-MS) analysis of oligonucleotides ever since the first report of its use for this purpose. This is not surprising, considering the exceptional performance of HFIP compared with carboxylic acids, which cause significant MS signal suppression in electrospray ionization. However, we have found that other fluorinated alcohols can also be utilized for mobile phase preparation and the choice of optimal fluorinated alcohol is determined by the ion-pairing (IP) agent. Although HFIP is a very good choice to be used alongside less hydrophobic IP agents, other fluorinated alcohols such as 1,1,1,3,3,3-hexafluoro-2-methyl-2-propanol (HFMIP) can significantly outperform HFIP when used with more hydrophobic IP agents. We also found that more acidic fluorinated alcohols assist with the transfer of oligonucleotides with secondary structure (e.g., folded strands and hairpins) into the gas phase. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Babak Basiri
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA
| | - Hilde van Hattum
- ProQR Therapeutics NV, Zernikedreef 9, 2333 CK, Leiden, The Netherlands
| | | | - Mandi M Murph
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA.
| |
Collapse
|
21
|
Miyaguchi H. Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry. J Vis Exp 2016:54402. [PMID: 27684516 PMCID: PMC5092034 DOI: 10.3791/54402] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
An improved version of a polymerase chain reaction (PCR)-restriction fragment length polymorphism (RFLP) method for genotyping toxic pufferfish species by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) is described. DNA extraction is carried out using a silica membrane-based DNA extraction kit. After the PCR amplification using a detergent-free PCR buffer, restriction enzymes are added to the solution without purifying the reaction solution. A reverse-phase silica monolith column and a Fourier transform high resolution mass spectrometer having a modified Kingdon trap analyzer are employed for separation and detection, respectively. The mobile phase, consisting of 400 mM 1,1,1,3,3,3-hexafluoro-2-propanol, 15 mM triethylamine (pH 7.9) and methanol, is delivered at a flow rate of 0.4 ml/min. The cycle time for LC/ESI-MS analysis is 8 min including equilibration of the column. Deconvolution software having an isotope distribution model of the oligonucleotide is used to calculate the corresponding monoisotopic mass from the mass spectrum. For analysis of oligonucleotides (range 26-79 nucleotides), mass accuracy was 0.62 ± 0.74 ppm (n = 280) and excellent accuracy and precision were sustained for 180 hr without use of a lock mass standard.
Collapse
|
22
|
Birdsall RE, Gilar M, Shion H, Yu YQ, Chen W. Reduction of metal adducts in oligonucleotide mass spectra in ion-pair reversed-phase chromatography/mass spectrometry analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:1667-1679. [PMID: 28328039 PMCID: PMC5094505 DOI: 10.1002/rcm.7596] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Revised: 04/28/2016] [Accepted: 05/01/2016] [Indexed: 05/09/2023]
Abstract
RATIONALE Electrospray ionization mass spectrometry (ESI-MS)-based techniques commonly used in oligonucleotide analyses are known to be sensitive to alkali metal adduct formation. Adducts directly impact the sensitivity of MS-based analyses as the available charge is distributed across the parent peak and adduct(s). The current study systematically evaluated common liquid chromatography (LC) components in LC/ESI-MS configurations used in oligonucleotide analysis to identify metal adduct contributions from LC instrumentation. METHODS A UPLC liquid chromatography system was configured with a single quadrupole MS detector (ACQUITY QDa, Waters Corp.) to monitor adduct formation in oligonucleotide separations. An ion-pairing mobile phase comprised of 15 mM triethylamine and 400 mM hexafluoro-2-propanol was used in conjunction with an oligonucleotide separation column (Waters OST BEH C18, 2.1 mm × 50 mm) for all separations. A 10-min method was used to provide statistical figures of merit and evaluate adduct formation over time. RESULTS Trace alkali metal salts in the mobile phase and reagents were determined to be the main source of metal salt adducts in LC/ESI-MS-based configurations. Non-specific adsorption sites located throughout the fluidic path contribute to adduct formation in oligonucleotide analyses. Ion-pairing mobile phases prepared at neutral or slightly basic pH result in up to a 57% loss of spectral abundance to adduct formation in the current study. CONCLUSIONS Implementation of a short low pH reconditioning step was observed to effectively displace trace metal salts non-specifically adsorbed to surfaces in the fluidic path and was able to maintain an average MS spectral abundance ≥94% with a high degree of repeatability (relative standard deviation (R.S.D.) 0.8%) over an extended time study. The proposed method offers the ability to rapidly regenerate adsorption sites with minimal impact on productivity while retaining assay sensitivity afforded by MS detection with reduced adduct formation. © 2016 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
| | - Martin Gilar
- Waters Corp., 34 Maple St, Milford, MA, 01757-3604, USA
| | - Henry Shion
- Waters Corp., 34 Maple St, Milford, MA, 01757-3604, USA
| | - Ying Qing Yu
- Waters Corp., 34 Maple St, Milford, MA, 01757-3604, USA
| | - Weibin Chen
- Waters Corp., 34 Maple St, Milford, MA, 01757-3604, USA
| |
Collapse
|
23
|
Steger J, Arnhard K, Haslacher S, Geiger K, Singer K, Schlapp M, Pitterl F, Oberacher H. Successful adaption of a forensic toxicological screening workflow employing nontargeted liquid chromatography-tandem mass spectrometry to water analysis. Electrophoresis 2016; 37:1085-94. [PMID: 26791338 DOI: 10.1002/elps.201500511] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2015] [Revised: 01/14/2016] [Accepted: 01/14/2016] [Indexed: 01/15/2023]
Abstract
Forensic toxicology and environmental water analysis share the common interest and responsibility in ensuring comprehensive and reliable confirmation of drugs and pharmaceutical compounds in samples analyzed. Dealing with similar analytes, detection and identification techniques should be exchangeable between scientific disciplines. Herein, we demonstrate the successful adaption of a forensic toxicological screening workflow employing nontargeted LC/MS/MS under data-dependent acquisition control and subsequent database search to water analysis. The main modification involved processing of an increased sample volume with SPE (500 mL vs. 1-10 mL) to reach LODs in the low ng/L range. Tandem mass spectra acquired with a qTOF instrument were submitted to database search. The targeted data mining strategy was found to be sensitive and specific; automated search produced hardly any false results. To demonstrate the applicability of the adapted workflow to complex samples, 14 wastewater effluent samples collected on seven consecutive days at the local wastewater-treatment plant were analyzed. Of the 88,970 fragment ion mass spectra produced, 8.8% of spectra were successfully assigned to one of the 1040 reference compounds included in the database, and this enabled the identification of 51 compounds representing important illegal drugs, members of various pharmaceutical compound classes, and metabolites thereof.
Collapse
Affiliation(s)
- Julia Steger
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Innsbruck, Austria
| | - Kathrin Arnhard
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Innsbruck, Austria
| | - Sandra Haslacher
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Innsbruck, Austria
| | | | - Klaus Singer
- Innsbrucker Kommunalbetriebe AG, Innsbruck, Austria
| | | | - Florian Pitterl
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Innsbruck, Austria
| | - Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Innsbruck, Austria
| |
Collapse
|
24
|
Abstract
A common feature of ribonucleic acids (RNAs) is that they can undergo a variety of chemical modifications. As nearly all of these chemical modifications result in an increase in the mass of the canonical nucleoside, mass spectrometry has long been a powerful approach for identifying and characterizing modified RNAs. Over the past several years, significant advances have been made in method development and software for interpreting tandem mass spectra resulting in approaches that can yield qualitative and quantitative information on RNA modifications, often at the level of sequence specificity. We discuss these advances along with instrumentation developments that have increased our ability to extract such information from relatively complex biological samples. With the increasing interest in how these modifications impact the epitranscriptome, mass spectrometry will continue to play an important role in bioanalytical investigations revolving around RNA.
Collapse
Affiliation(s)
- Collin Wetzel
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, PO Box 210172. and University of Cincinnati, Cincinnati, OH 45221-0172, USA.
| | | |
Collapse
|
25
|
Smith M, Beck T. Quantitation of a low level coeluting impurity present in a modified oligonucleotide by both LC-MS and NMR. J Pharm Biomed Anal 2015; 118:34-40. [PMID: 26512997 DOI: 10.1016/j.jpba.2015.10.019] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Revised: 10/07/2015] [Accepted: 10/13/2015] [Indexed: 01/13/2023]
Abstract
This paper describes the use of two complementary techniques, LC-MS and NMR, to quantify a low level mono phosphate substituted impurity in an oligonucleotide drug substance. This impurity is the result of a sulphurisation failure, leading to the production of a sequence where a phosphorothioate linkage is replaced by a phosphate. Few quantitative methods are possible to analyse these challenging molecules especially if reversed phase ion pair chromatography, one of the most commonly used techniques for the separation of oligonucleotides, is unable to resolve the impurity in question. With the use of a standard addition method it could be demonstrated that both analytical techniques show equivalency and furthermore, the LC-MS method alone with additional validation has the potential to perform this quantitative assay with a high degree of accuracy.
Collapse
Affiliation(s)
- Marco Smith
- GlaxoSmithKline, Medicines Research Centre, Gunnels Wood Road, Stevenage, Hertfordshire, UK.
| | - Tony Beck
- GlaxoSmithKline, Medicines Research Centre, Gunnels Wood Road, Stevenage, Hertfordshire, UK
| |
Collapse
|