1
|
Hu S, Wang Y, Wang Y, Chen X, Tong R. Dielectrophoretic separation and purification: From colloid and biological particles to droplets. J Chromatogr A 2024; 1731:465155. [PMID: 39032216 DOI: 10.1016/j.chroma.2024.465155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 07/06/2024] [Accepted: 07/08/2024] [Indexed: 07/22/2024]
Abstract
It is indispensable to realize the high level of purification and separation, so that objective particles, such as malignant cells, harmful bacteria, and special proteins or biological molecules, could satisfy the high precise measurement in the pharmaceutical analysis, clinical diagnosis, targeted therapy, and food defense. In addition, this could reveal the intrinsic nature and evolution mechanisms of individual biological variations. Consequently, many techniques related to optical tweezers, microfluidics, acoustophoresis, and electrokinetics can be broadly used to achieve micro- and nano-scale particle separations. Dielectrophoresis (DEP) has been used for various manipulation, concentration, transport, and separation processes of biological particles owing to its early development, mature theory, low cost, and high throughput. Although numerous reviews have discussed the biological applications of DEP techniques, comprehensive descriptions of micro- and nano-scale particle separations feature less frequently in the literature. Therefore, this review summarizes the current state of particle separation attention to relevant technological developments and innovation, including theoretical simulation, microchannel structure, electrode material, pattern and its layout. Moreover, a brief overview of separation applications using DEP in combination with other technologies is also provided. Finally, conclusions, future guidelines, and suggestions for potential promotion are highlighted.
Collapse
Affiliation(s)
- Sheng Hu
- College of Information Science and Engineering, Northeastern University, Shenyang, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China.
| | - Yangcheng Wang
- College of Information Science and Engineering, Northeastern University, Shenyang, China
| | - Yanzhe Wang
- Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China
| | - Xiaoming Chen
- College of Information Science and Engineering, Northeastern University, Shenyang, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China
| | - Ruijie Tong
- College of Information Science and Engineering, Northeastern University, Shenyang, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China
| |
Collapse
|
2
|
Strayer J, Choe H, Wu X, Weigand M, Gómez-Pastora J, Zborowski M, Chalmers JJ. Measuring magnetic force field distributions in microfluidic devices: Experimental and numerical approaches. Electrophoresis 2024; 45:743-751. [PMID: 38041407 DOI: 10.1002/elps.202300093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 11/13/2023] [Accepted: 11/20/2023] [Indexed: 12/03/2023]
Abstract
Precisely and accurately determining the magnetic force and its spatial distribution in microfluidic devices is challenging. Typically, magnetic microfluidic devices are designed in a way to both maximize the force within the separation region and to minimize the necessity for knowing such details-such as designing magnetic geometries that create regions of nearly constant magnetic force or that dictate the behavior of the magnetic force to be highly predictable in a specified region. In this work, we present a method to determine the spatial distribution of the magnetic force field in a magnetic microfluidic device by particle tracking magnetophoresis. Polystyrene microparticles were suspended in a paramagnetic fluid, gadolinium, and this suspension was exposed to various magnetic field geometries. Polystyrene particle motion was tracked using a microscope and images processed using Fiji (ImageJ). From a sample with a large spatial distribution of particle tracks, the magnetic force field distribution was calculated. The force field distribution was fitted to nonlinear spatial distribution models. These experimental models are compared to and supported by 3D simulations of the magnetic force field in COMSOL.
Collapse
Affiliation(s)
- Jacob Strayer
- William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio, USA
| | - Hyeon Choe
- William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio, USA
| | - Xian Wu
- William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio, USA
| | - Mitchell Weigand
- William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio, USA
| | | | - Maciej Zborowski
- Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio, USA
| | - Jeffrey J Chalmers
- William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
3
|
Vaghef-Koodehi A, Lapizco-Encinas BH. Switching Separation Migration Order by Switching Electrokinetic Regime in Electrokinetic Microsystems. BIOSENSORS 2024; 14:119. [PMID: 38534226 DOI: 10.3390/bios14030119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Revised: 02/10/2024] [Accepted: 02/18/2024] [Indexed: 03/28/2024]
Abstract
Analyte migration order is a major aspect in all migration-based analytical separations methods. Presented here is the manipulation of the migration order of microparticles in an insulator-based electrokinetic separation. Three distinct particle mixtures were studied: a binary mixture of particles with similar electrical charge and different sizes, and two tertiary mixtures of particles of distinct sizes. Each one of the particle mixtures was separated twice, the first separation was performed under low voltage (linear electrokinetic regime) and the second separation was performed under high voltage (nonlinear electrokinetic regime). Linear electrophoresis, which discriminates particles by charge, is the dominant electrokinetic effect in the linear regime; while nonlinear electrophoresis, which discriminates particles by size and shape, is the dominant electrokinetic effect in the nonlinear regime. The separation results obtained with the three particle mixtures illustrated that particle elution order can be changed by switching from the linear electrokinetic regime to the nonlinear electrokinetic regime. Also, in all cases, better separation performances in terms of separation resolution (Rs) were obtained by employing the nonlinear electrokinetic regime allowing nonlinear electrophoresis to be the discriminatory electrokinetic mechanism. These findings could be applied to analyze complex samples containing bioparticles of interest within the micron size range. This is the first report where particle elution order is altered in an iEK system.
Collapse
Affiliation(s)
- Alaleh Vaghef-Koodehi
- Microscale Bioseparations Laboratory, Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, NY 14623, USA
| | - Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory, Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, NY 14623, USA
| |
Collapse
|
4
|
Novel Approaches Concerning the Numerical Modeling of Particle and Cell Separation in Microchannels: A Review. Processes (Basel) 2022. [DOI: 10.3390/pr10061226] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
The demand for precise separation of particles, cells, and other biological matter has significantly increased in recent years, leading to heightened scientific interest in this topic. More recently, due to advances in computational techniques and hardware, numerical simulations have been used to guide the design of separation devices. In this article, we establish the theoretical basis governing fluid flow and particle separation and then summarize the computational work performed in the field of particle and cell separation in the last five years with an emphasis on magnetic, dielectric, and acoustic methods. Nearly 70 articles are being reviewed and categorized depending on the type of material separated, fluid medium, software used, and experimental validation, with a brief description of some of the most notable results. Finally, further conclusions, future guidelines, and suggestions for potential improvement are highlighted.
Collapse
|
5
|
Panklang N, Techaumnat B, Wisitsoraat A, Putaporntip C, Chotivanich K, Suzuki Y. A discrete dielectrophoresis device for the separation of malaria‐infected cells. Electrophoresis 2022; 43:1347-1356. [DOI: 10.1002/elps.202100271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 03/07/2022] [Accepted: 03/11/2022] [Indexed: 11/06/2022]
Affiliation(s)
- Nitipong Panklang
- Department of Electrical Engineering Faculty of Engineering Chulalongkorn University Bangkok Thailand
| | - Boonchai Techaumnat
- Department of Electrical Engineering Faculty of Engineering Chulalongkorn University Bangkok Thailand
- Biomedical Engineering Research Center Faculty of Engineering Chulalongkorn University Bangkok Thailand
| | - Anurat Wisitsoraat
- Nanoelectronics and MEMS Laboratory National Electronics and Computer Technology Center Pathumthani Thailand
| | - Chaturong Putaporntip
- Molecular Biology of Malaria and Opportunistic Parasites Research Unit Department of Parasitology Faculty of Medicine Chulalongkorn University Bangkok Thailand
| | - Kesinee Chotivanich
- Department of Clinical Tropical Medicine Mahidol Oxford Tropical Medicine Research Unit Faculty of Tropical Medicine Mahidol University Bangkok Thailand
| | - Yuji Suzuki
- Department of Mechanical Engineering The University of Tokyo Tokyo Japan
| |
Collapse
|
6
|
Lapizco-Encinas BH. The latest advances on nonlinear insulator-based electrokinetic microsystems under direct current and low-frequency alternating current fields: a review. Anal Bioanal Chem 2021; 414:885-905. [PMID: 34664103 DOI: 10.1007/s00216-021-03687-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 09/17/2021] [Accepted: 09/21/2021] [Indexed: 12/11/2022]
Abstract
This review article presents an overview of the evolution of the field of insulator-based dielectrophoresis (iDEP); in particular, it focuses on insulator-based electrokinetic (iEK) systems stimulated with direct current and low-frequency(< 1 kHz) AC electric fields. The article covers the surge of iDEP as a research field where many different device designs were developed, from microchannels with arrays of insulating posts to devices with curved walls and nano- and micropipettes. All of these systems allowed for the manipulation and separation of a wide array of particles, ranging from macromolecules to microorganisms, including clinical and biomedical applications. Recent experimental reports, supported by important theoretical studies in the field of physics and colloids, brought attention to the effects of electrophoresis of the second kind in these systems. These recent findings suggest that DEP is not the main force behind particle trapping, as it was believed for the last two decades. This new research suggests that particle trapping, under DC and low-frequency AC potentials, mainly results from a balance between electroosmotic and electrophoretic effects (linear and nonlinear); although DEP is present in these systems, it is not a dominant force. Considering these recent studies, it is proposed to rename this field from DC-iDEP to DC-iEK (and low-frequency AC-iDEP to low-frequency AC-iEK). Whereas much research is still needed, this is an exciting time in the field of microscale EK systems, as these new findings seem to explain the challenges with modeling particle migration and trapping in iEK devices, and provide perhaps a better understanding of the mechanisms behind particle trapping.
Collapse
Affiliation(s)
- Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, Institute Hall (Bldg. 73), Room 3103, 160 Lomb Memorial Drive, Rochester, NY, 14623-5604, USA.
| |
Collapse
|
7
|
Duncan JL, Davalos RV. A review: Dielectrophoresis for characterizing and separating similar cell subpopulations based on bioelectric property changes due to disease progression and therapy assessment. Electrophoresis 2021; 42:2423-2444. [PMID: 34609740 DOI: 10.1002/elps.202100135] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 09/19/2021] [Accepted: 09/23/2021] [Indexed: 12/16/2022]
Abstract
This paper reviews the use of dielectrophoresis for high-fidelity separations and characterizations of subpopulations to highlight the recent advances in the electrokinetic field as well as provide insight into its progress toward commercialization. The role of cell subpopulations in heterogeneous clinical samples has been studied to deduce their role in disease progression and therapy resistance for instances such as cancer, tissue regeneration, and bacterial infection. Dielectrophoresis (DEP), a label-free electrokinetic technique, has been used to characterize and separate target subpopulations from mixed samples to determine disease severity, cell stemness, and drug efficacy. Despite its high sensitivity to characterize similar or related cells based on their differing bioelectric signatures, DEP has been slowly adopted both commercially and clinically. This review addresses the use of dielectrophoresis for the identification of target cell subtypes in stem cells, cancer cells, blood cells, and bacterial cells dependent on cell state and therapy exposure and addresses commercialization efforts in light of its sensitivity and future perspectives of the technology, both commercially and academically.
Collapse
Affiliation(s)
- Josie L Duncan
- Bioelectromechanical Systems Laboratory, Department of Mechanical Engineering, Virginia Tech, Blacksburg, Virginia, USA.,Bioelectromechanical Systems Laboratory, Wake Forest School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, Virginia, USA
| | - Rafael V Davalos
- Bioelectromechanical Systems Laboratory, Department of Mechanical Engineering, Virginia Tech, Blacksburg, Virginia, USA.,Bioelectromechanical Systems Laboratory, Wake Forest School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, Virginia, USA
| |
Collapse
|
8
|
Liu H, Zhao Y, Yao C, Schmelz EM, Davalos RV. Differential effects of nanosecond pulsed electric fields on cells representing progressive ovarian cancer. Bioelectrochemistry 2021; 142:107942. [PMID: 34509872 DOI: 10.1016/j.bioelechem.2021.107942] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 08/19/2021] [Accepted: 08/23/2021] [Indexed: 12/12/2022]
Abstract
Nanosecond pulsed electric fields (nsPEFs) may induce differential effects on tumor cells from different disease stages and could be suitable for treating tumors by preferentially targeting the late-stage/highly aggressive tumor cells. In this study, we investigated the nsPEF responses of mouse ovarian surface epithelial (MOSE) cells representing progressive ovarian cancer from benign to malignant stages and highly aggressive tumor-initiating-like cells. We established the cell-seeded 3D collagen scaffolds cultured with or without Nocodazole (eliminating the influence of cell proliferation on ablation outcome) to observe the ablation effects at 3 h and 24 h after treatment and compared the corresponding thresholds obtained by numerically calculated electric field distribution. The results showed that nsPEFs induced larger ablation areas with lower thresholds as the cell progress from benign, malignant to a highly aggressive phenotype. This differential effect was not affected by the different doubling times of the cells, as apparent by similar ablation induction after a synergistic treatment of nsPEFs and Nocodazole. The result suggests that nsPEFs could induce preferential ablation effects on highly aggressive and malignant ovarian cancer cells than their benign counterparts. This study provides an experimental basis for the research on killing malignant tumor cells via electrical treatments and may have clinical implications for treating tumors and preventing tumor recurrence after treatment.
Collapse
Affiliation(s)
- Hongmei Liu
- School of Electrical Engineering, Chongqing University, Chongqing 400033, China; Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, USA
| | - Yajun Zhao
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, USA; College of Electrical Engineering and Control Science, Nanjing Tech. University, Nanjing 211816, China
| | - Chenguo Yao
- School of Electrical Engineering, Chongqing University, Chongqing 400033, China.
| | - Eva M Schmelz
- Department of Human Nutrition, Foods and Exercise, Virginia Tech, Blacksburg, VA 24061, USA.
| | - Rafael V Davalos
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, USA.
| |
Collapse
|
9
|
Hyler AR, Hong D, Davalos RV, Swami NS, Schmelz EM. A novel ultralow conductivity electromanipulation buffer improves cell viability and enhances dielectrophoretic consistency. Electrophoresis 2021; 42:1366-1377. [PMID: 33687759 DOI: 10.1002/elps.202000324] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 01/23/2021] [Accepted: 02/27/2021] [Indexed: 12/21/2022]
Abstract
Cell separation has become a critical diagnostic, research, and treatment tool for personalized medicine. Despite significant advances in cell separation, most widely used applications require the use of multiple, expensive antibodies to known markers in order to identify subpopulations of cells for separation. Dielectrophoresis (DEP) provides a biophysical separation technique that can target cell subpopulations based on phenotype without labels and return native cells for downstream analysis. One challenge in employing any DEP device is the sample being separated must be transferred into an ultralow conductivity medium, which can be detrimental in retaining cells' native phenotypes for separation. Here, we measured properties of traditional DEP reagents and determined that after just 1-2 h of exposure and subsequent culture, cells' viability was significantly reduced below 50%. We developed and tested a novel buffer (Cyto Buffer) that achieved 6 weeks of stable shelf-life and demonstrated significantly improved viability and physiological properties. We then determined the impact of Cyto Buffer on cells' dielectric properties and morphology and found that cells retained properties more similar to that of their native media. Finally, we vetted Cyto Buffer's usability on a cell separation platform (Cyto R1) to determine combined efficacy for cell separations. Here, more than 80% of cells from different cell lines were recovered and were determined to be >70% viable following exposure to Cyto Buffer, flow stimulation, electromanipulation, and downstream collection and growth. The developed buffer demonstrated improved opportunities for electrical cell manipulation, enrichment, and recovery for next generation cell separations.
Collapse
Affiliation(s)
| | - Daly Hong
- CytoRecovery, Inc., Blacksburg, VA, USA
| | - Rafael V Davalos
- Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, USA
| | - Nathan S Swami
- Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, USA
| | - Eva M Schmelz
- Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, USA.,Human Nutrition, Foods and Exercise, Virginia Tech, Blacksburg, VA, USA
| |
Collapse
|
10
|
Gustafson KT, Huynh KT, Heineck D, Bueno J, Modestino A, Kim S, Gower A, Armstrong R, Schutt CE, Ibsen SD. Automated fluorescence quantification of extracellular vesicles collected from blood plasma using dielectrophoresis. LAB ON A CHIP 2021; 21:1318-1332. [PMID: 33877235 DOI: 10.1039/d0lc00940g] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Tumor-secreted exosomes and other extracellular vesicles (EVs) in circulation contain valuable biomarkers for early cancer detection and screening. We have previously demonstrated collection of cancer-derived nanoparticles (NPs) directly from whole blood and plasma with a chip-based technique that uses a microelectrode array to generate dielectrophoretic (DEP) forces. This technique enables direct recovery of NPs from whole blood and plasma. The biomarker payloads associated with collected particles can be detected and quantified with immunostaining. Accurately separating the fluorescence intensity of stained biomarkers from background (BG) levels becomes a challenge when analyzing the blood from early-stage cancer patients in which biomarker concentrations are low. To address this challenge, we developed two complementary techniques to standardize the quantification of fluorescently immunolabeled biomarkers collected and concentrated at predictable locations within microfluidic chips. The first technique was an automated algorithm for the quantitative analysis of fluorescence intensity at collection regions within the chip compared to levels at adjacent regions. The algorithm used predictable locations of particle collection within the chip geometry to differentiate regions of collection and BG. We successfully automated the identification and removal of optical artifacts from quantitative calculations. We demonstrated that the automated system performs nearly the same as a human user following a standard protocol for manual artifact removal with Pearson's r-values of 0.999 and 0.998 for two different biomarkers (n = 36 patients). We defined a usable dynamic range of fluorescence intensities corresponding to 1 to 2000 arbitrary units (a.u.). Fluorescence intensities within the dynamic range increased linearly with respect to exposure time and particle concentration. The second technique was the implementation of an internal standard to adjust levels of biomarker fluorescence based on the relative collection efficiency of the chip. Use of the internal standard reduced variability in measured biomarker levels due to differences in chip-to-chip collection efficiency, especially at low biomarker concentrations. The internal standard did not affect linear trends between fluorescence intensity and exposure time. Adjustments using the internal standard improved linear trends between fluorescence intensity and particle concentration. The optical quantification techniques described in this paper can be easily adapted for other lab-on-a-chip platforms that have predefined regions of biomarker or particle collection and that rely on fluorescence detection.
Collapse
Affiliation(s)
- Kyle T Gustafson
- Cancer Early Detection Advanced Research Center, Knight Cancer Institute, Oregon Health & Science University, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Lapizco-Encinas BH. Microscale nonlinear electrokinetics for the analysis of cellular materials in clinical applications: a review. Mikrochim Acta 2021; 188:104. [PMID: 33651196 DOI: 10.1007/s00604-021-04748-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 02/06/2021] [Indexed: 12/16/2022]
Abstract
This review article presents a discussion of some of the latest advancements in the field of microscale electrokinetics for the analysis of cells and subcellular materials in clinical applications. The introduction presents an overview on the use of electric fields, i.e., electrokinetics, in microfluidics devices and discusses the potential of electrokinetic-based methods for the analysis of liquid biopsies in clinical and point-of-care applications. This is followed by four comprehensive sections that present some of the newest findings on the analysis of circulating tumor cells, blood (red blood cells, white blood cells, and platelets), stem cells, and subcellular particles (extracellular vesicles and mitochondria). The valuable contributions discussed here (with 131 references) were mainly published during the last 3 to 4 years, providing the reader with an overview of the state-of-the-art in the use of microscale electrokinetic methods in clinical analysis. Finally, the conclusions summarize the main advancements and discuss the future prospects.
Collapse
Affiliation(s)
- Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, Institute Hall (Bldg. 73), Room 3103, 160 Lomb Memorial Drive, Rochester, NY, 14623-5604, USA.
| |
Collapse
|
12
|
Sarno B, Heineck D, Heller MJ, Ibsen SD. Dielectrophoresis: Developments and applications from 2010 to 2020. Electrophoresis 2021; 42:539-564. [PMID: 33191521 PMCID: PMC7986072 DOI: 10.1002/elps.202000156] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 09/22/2020] [Accepted: 10/21/2020] [Indexed: 12/19/2022]
Abstract
The 20th century has seen tremendous innovation of dielectrophoresis (DEP) technologies, with applications being developed in areas ranging from industrial processing to micro- and nanoscale biotechnology. From 2010 to present day, there have been 981 publications about DEP. Of over 2600 DEP patents held by the United States Patent and Trademark Office, 106 were filed in 2019 alone. This review focuses on DEP-based technologies and application developments between 2010 and 2020, with an aim to highlight the progress and to identify potential areas for future research. A major trend over the last 10 years has been the use of DEP techniques for biological and clinical applications. It has been used in various forms on a diverse array of biologically derived molecules and particles to manipulate and study them including proteins, exosomes, bacteria, yeast, stem cells, cancer cells, and blood cells. DEP has also been used to manipulate nano- and micron-sized particles in order to fabricate different structures. The next 10 years are likely to see the increase in DEP-related patent applications begin to result in a greater level of technology commercialization. Also during this time, innovations in DEP technology will likely be leveraged to continue the existing trend to further biological and medical-focused applications as well as applications in microfabrication. As a tool leveraged by engineering and imaginative scientific design, DEP offers unique capabilities to manipulate small particles in precise ways that can help solve problems and enable scientific inquiry that cannot be addressed using conventional methods.
Collapse
Affiliation(s)
- Benjamin Sarno
- Oregon Health and Science University–The Knight Cancer Institute's Cancer Early Detection Advanced Research CenterPortlandORUSA
- University of California San Diego–NanoengineeringLa JollaCAUSA
| | - Daniel Heineck
- Oregon Health and Science University–The Knight Cancer Institute's Cancer Early Detection Advanced Research CenterPortlandORUSA
| | - Michael J. Heller
- Oregon Health and Science University–The Knight Cancer Institute's Cancer Early Detection Advanced Research CenterPortlandORUSA
- University of California San Diego–NanoengineeringLa JollaCAUSA
| | - Stuart D. Ibsen
- Oregon Health and Science University–The Knight Cancer Institute's Cancer Early Detection Advanced Research CenterPortlandORUSA
- Oregon Health and Science University–Biomedical EngineeringPortlandORUSA
| |
Collapse
|
13
|
Ramirez-Murillo CJ, de Los Santos-Ramirez JM, Perez-Gonzalez VH. Toward low-voltage dielectrophoresis-based microfluidic systems: A review. Electrophoresis 2020; 42:565-587. [PMID: 33166414 DOI: 10.1002/elps.202000213] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 10/27/2020] [Accepted: 11/02/2020] [Indexed: 12/13/2022]
Abstract
Dielectrophoretically driven microfluidic devices have demonstrated great applicability in biomedical engineering, diagnostic medicine, and biological research. One of the potential fields of application for this technology is in point-of-care (POC) devices, ideally allowing for portable, fully integrated, easy to use, low-cost diagnostic platforms. Two main approaches exist to induce dielectrophoresis (DEP) on suspended particles, that is, electrode-based DEP and insulator-based DEP, each featuring different advantages and disadvantages. However, a shared concern lies in the input voltage used to generate the electric field necessary for DEP to take place. Therefore, input voltage can determine portability of a microfluidic device. This review outlines the recent advances in reducing stimulation voltage requirements in DEP-driven microfluidics.
Collapse
|
14
|
Creation of an electrokinetic characterization library for the detection and identification of biological cells. Anal Bioanal Chem 2020; 412:3935-3945. [DOI: 10.1007/s00216-020-02621-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 03/19/2020] [Accepted: 03/26/2020] [Indexed: 11/26/2022]
|
15
|
Trainito CI, Sweeney DC, Čemažar J, Schmelz EM, Français O, Le Pioufle B, Davalos RV. Characterization of sequentially-staged cancer cells using electrorotation. PLoS One 2019; 14:e0222289. [PMID: 31536516 PMCID: PMC6752768 DOI: 10.1371/journal.pone.0222289] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 08/26/2019] [Indexed: 12/21/2022] Open
Abstract
The identification and separation of cells from heterogeneous populations is critical to the diagnosis of diseases. Label-free methodologies in particular have been developed to manipulate individual cells using properties such as density and morphology. The electrical properties of malignant cells, including the membrane capacitance and cytoplasmic conductivity, have been demonstrated to be altered compared to non-malignant cells of similar origin. Here, we exploit these changes to characterize individual cells in a sequentially-staged in vitro cancer model using electrorotation (EROT)—the rotation of a cell induced by a rotating electric field. Using a microfabricated device, a dielectrophoretic force to suspend cells while measuring their angular velocity resulting from an EROT force applied at frequencies between 3 kHz to 10 MHz. We experimentally determine the EROT response for cells at three stages of malignancy and analyze the resultant spectra by considering models that include the effect of the cell membrane alone (single-shell model) and the combined effect of the cell membrane and nucleus (double-shell model). We find that the cell membrane is largely responsible for a given cell’s EROT response between 3 kHz and 10 MHz. Our results also indicate that membrane capacitance, membrane conductance, and cytoplasmic conductivity increase with an increasingly malignant phenotype. Our results demonstrate the potential of using electrorotation as a means making of non-invasive measurements to characterize the dielectric properties of cancer cells.
Collapse
Affiliation(s)
| | - Daniel C. Sweeney
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, Virginia, United States of America
| | - Jaka Čemažar
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, Virginia, United States of America
| | - Eva M. Schmelz
- Department of Human Nutrition, Food, and Exercise, Virginia Tech, Blacksburg, Virginia, United States of America
| | - Olivier Français
- CNRS SATIE Institut d’Alembert ENS Paris Saclay, France
- ESIEE-Paris, ESYCOM (FRE 2028), UPE, Noisy-Le-Grand, France
| | | | - Rafael V. Davalos
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, Virginia, United States of America
- * E-mail:
| |
Collapse
|
16
|
Effect of structural parameters of an electrostatic separator on the removal of catalyst particles from fluid catalytic cracking slurry. Sep Purif Technol 2019. [DOI: 10.1016/j.seppur.2019.04.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
17
|
Alinezhadbalalami N, Douglas TA, Balani N, Verbridge SS, Davalos RV. The feasibility of using dielectrophoresis for isolation of glioblastoma subpopulations with increased stemness. Electrophoresis 2019; 40:2592-2600. [PMID: 31127957 DOI: 10.1002/elps.201900026] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 05/17/2019] [Accepted: 05/20/2019] [Indexed: 01/17/2023]
Abstract
Cancer stem cells (CSCs) are aggressive subpopulations with increased stem-like properties. CSCs are usually resistant to most standard therapies and are responsible for tumor repropagation. Similar to normal stem cells, isolation of CSCs is challenging due to the lack of reliable markers. Antigen-based sorting of CSCs usually requires staining with multiple markers, making the experiments complicated, expensive, and sometimes unreliable. Here, we study the feasibility of using dielectrophoresis (DEP) for isolation of glioblastoma cells with increased stemness. We culture a glioblastoma cell line in the form of neurospheres as an in vitro model for glioblastoma stem cells. We demonstrate that spheroid forming cells have higher expression of stem cell marker, nestin. Next, we show that dielectric properties of neurospheres change as a result of changing culture conditions. Our results indicate that spheroid forming cells need higher voltages to experience the same DEP force magnitude compared to normal monolayer cultures of glioblastoma cell line. This study confirms the possibility of using DEP to isolate glioblastoma stem cells.
Collapse
Affiliation(s)
- Nastaran Alinezhadbalalami
- Bioelectromechanical Systems Lab, Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Blacksburg, VA, USA.,Laboratory of Integrative Tumor Ecology, Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Blacksburg, VA, USA
| | - Temple A Douglas
- Bioelectromechanical Systems Lab, Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Blacksburg, VA, USA
| | - Nikita Balani
- Bioelectromechanical Systems Lab, Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Blacksburg, VA, USA
| | - Scott S Verbridge
- Laboratory of Integrative Tumor Ecology, Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Blacksburg, VA, USA
| | - Rafael V Davalos
- Bioelectromechanical Systems Lab, Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Blacksburg, VA, USA
| |
Collapse
|
18
|
Xu J, Li B, Sun Z, Wang Z, Liu B, Zhang M. Effects of electrode geometry on emulsion dehydration efficiency. Colloids Surf A Physicochem Eng Asp 2019. [DOI: 10.1016/j.colsurfa.2019.01.069] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
19
|
Douglas TA, Alinezhadbalalami N, Balani N, Schmelz EM, Davalos RV. Separation of Macrophages and Fibroblasts Using Contactless Dielectrophoresis and a Novel ImageJ Macro. Bioelectricity 2019; 1:49-55. [PMID: 32292890 DOI: 10.1089/bioe.2018.0004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Background: This study presents a label-free method of separating macrophages and fibroblasts, cell types critically associated with tumors. Materials and Methods: Contactless dielectrophoresis (DEP) devices were used to separate fibroblasts from macrophages by selectively trapping one population. An ImageJ macro was developed to determine the percentage of each population moving or stationary at a given point in time in a video. Results: At 350Vrms, 20 kHz, and 1.25 μL/min, more than 90% of fibroblasts were trapped while less than 20% of macrophages were trapped. Conclusions: Contactless DEP was used to study macrophage and fibroblast separation as a proof-of-concept study for separating cells in the tumor microenvironment. The associated ImageJ macro could be used in other microfluidic cell separation studies.
Collapse
Affiliation(s)
- Temple Anne Douglas
- School of Biomedical Engineering and Sciences, Virginia Tech - Wake Forest University, Blacksburg, Virginia
| | - Nastaran Alinezhadbalalami
- School of Biomedical Engineering and Sciences, Virginia Tech - Wake Forest University, Blacksburg, Virginia
| | - Nikita Balani
- School of Biomedical Engineering and Sciences, Virginia Tech - Wake Forest University, Blacksburg, Virginia
| | - Eva M Schmelz
- Department of Human Nutrition, Foods and Exercise, Virginia Tech, Blacksburg, Virginia
| | - Rafael V Davalos
- School of Biomedical Engineering and Sciences, Virginia Tech - Wake Forest University, Blacksburg, Virginia
| |
Collapse
|
20
|
Yin D, Zhang X, Han X, Yang J, Hu N. Multi-Stage Particle Separation based on Microstructure Filtration and Dielectrophoresis. MICROMACHINES 2019; 10:mi10020103. [PMID: 30708953 PMCID: PMC6412275 DOI: 10.3390/mi10020103] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2018] [Revised: 01/27/2019] [Accepted: 01/29/2019] [Indexed: 11/16/2022]
Abstract
Particle separation is important in chemical and biomedical analysis. Among all particle separation approaches, microstructure filtration which based particles size difference has turned into one of the most commonly methods. By controlling the movement of particles, dielectrophoresis has also been widely adopted in particle separation. This work presents a microfluidic device which combines the advantages of microfilters and dielectrophoresis to separate micro-particles and cells. A three-dimensional (3D) model was developed to calculate the distributions of the electric field gradient at the two filter stages. Polystyrene particles with three different sizes were separated by micropillar array structure by applying a 35-Vpp AC voltage at 10 KHz. The blocked particles were pushed off the filters under the negative dielectrophoretic force and drag force. A mixture of Haematococcus pluvialis cells and Bracteacoccus engadinensis cells with different sizes were also successfully separated by this device, which proved that the device can separate both biological samples and polystyrene particles.
Collapse
Affiliation(s)
- Danfen Yin
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| | - Xiaoling Zhang
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| | - Xianwei Han
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| | - Jun Yang
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| | - Ning Hu
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| |
Collapse
|
21
|
Lapizco-Encinas BH. On the recent developments of insulator-based dielectrophoresis: A review. Electrophoresis 2018; 40:358-375. [PMID: 30112789 DOI: 10.1002/elps.201800285] [Citation(s) in RCA: 80] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 08/06/2018] [Accepted: 08/08/2018] [Indexed: 01/26/2023]
Abstract
Insulator-based dielectrophoresis (iDEP), also known as electrodeless DEP, has become a well-known dielectrophoretic technique, no longer viewed as a new methodology. Significant advances on iDEP have been reported during the last 15 years. This review article aims to summarize some of the most important findings on iDEP organized by the type of dielectrophoretic mode: streaming and trapping iDEP. The former is primarily used for particle sorting, while the latter has great capability for particle enrichment. The characteristics of a wide array of devices are discussed for each type of dielectrophoretic mode in order to present an overview of the distinct designs and applications developed with iDEP. A short section on Joule heating effects and electrothermal flow is also included to highlight some of the challenges in the utilization of iDEP systems. The significant progress on iDEP illustrates its potential for a large number of applications, ranging from bioanalysis to clinical and biomedical assessments. The present article discusses the work on iDEP by numerous research groups around the world, with the aim of proving the reader with an overview of the state-of-the-art in iDEP microfluidic systems.
Collapse
|
22
|
Polniak DV, Goodrich E, Hill N, Lapizco-Encinas BH. Separating large microscale particles by exploiting charge differences with dielectrophoresis. J Chromatogr A 2018; 1545:84-92. [DOI: 10.1016/j.chroma.2018.02.051] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2017] [Revised: 02/18/2018] [Accepted: 02/24/2018] [Indexed: 10/18/2022]
|