1
|
Hu S, Ji J, Chen X, Tong R. Dielectrophoresis: Measurement technologies and auxiliary sensing applications. Electrophoresis 2024; 45:1574-1596. [PMID: 38738705 DOI: 10.1002/elps.202300299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 04/17/2024] [Accepted: 04/24/2024] [Indexed: 05/14/2024]
Abstract
Dielectrophoresis (DEP), which arises from the interaction between dielectric particles and an aqueous solution in a nonuniform electric field, contributes to the manipulation of nano and microparticles in many fields, including colloid physics, analytical chemistry, molecular biology, clinical medicine, and pharmaceutics. The measurement of the DEP force could provide a more complete solution for verifying current classical DEP theories. This review reports various imaging, fluidic, optical, and mechanical approaches for measuring the DEP forces at different amplitudes and frequencies. The integration of DEP technology into sensors enables fast response, high sensitivity, precise discrimination, and label-free detection of proteins, bacteria, colloidal particles, and cells. Therefore, this review provides an in-depth overview of DEP-based fabrication and measurements. Depending on the measurement requirements, DEP manipulation can be classified into assistance and integration approaches to improve sensor performance. To this end, an overview is dedicated to developing the concept of trapping-on-sensing, improving its structure and performance, and realizing fully DEP-assisted lab-on-a-chip systems.
Collapse
Affiliation(s)
- Sheng Hu
- College of Information Science and Engineering, Northeastern University, Shenyang, P. R. China
- Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, P. R. China
| | - Junyou Ji
- College of Information Science and Engineering, Northeastern University, Shenyang, P. R. China
| | - Xiaoming Chen
- College of Information Science and Engineering, Northeastern University, Shenyang, P. R. China
- Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, P. R. China
| | - Ruijie Tong
- College of Information Science and Engineering, Northeastern University, Shenyang, P. R. China
- Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, P. R. China
| |
Collapse
|
2
|
Zhang W, Jiang J, Liu T, Wang X, Zhang W, Wang Y, Chu Z, Jin W. A rapid and ultrasensitive cardiac troponin I aptasensor based on an ion-sensitive field-effect transistor with extended gate. Talanta 2024; 277:126364. [PMID: 38861763 DOI: 10.1016/j.talanta.2024.126364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 05/27/2024] [Accepted: 06/04/2024] [Indexed: 06/13/2024]
Abstract
Acute myocardial infarction (AMI) is a life-threatening disease with a short course and a high mortality rate. However, it is still a great challenge to achieve the on-site diagnosis of this disease within minutes, meaning there is an urgent need to develop an efficient technology for realizing the rapid diagnosis and early warning of AMI in clinical emergencies. In this study, an ultrasensitive electrochemical aptasensor based on an extended-gate ion-sensitive field-effect transistor (EGISFET) was designed to achieve the quantitative assay of cardiac troponin I (cTnI), which is a highly sensitive and specific biomarker of AMI, within only 5 min. The EGISFET exhibits extremely high detection sensitivity due to its separated structure with a large sensing area and the surface-modified Prussian blue-gold nanoparticles (PB-AuNPs) composite, which serves as a signal magnifier and DNA loading platform for good electrocatalytic ability with a large specific area. Additionally, a target-induced strand-release strategy is proposed to shorten the recognition time of cTnI using a particular DNA strand. Under optimal conditions, the as-prepared aptasensor exhibits a wide linear range of 1-1000 pg/mL, an ultralow detection limit of 0.3 pg/mL, and reliable detection results in real serum samples. It is highly anticipated that this EGISFET-based aptasensor will have broad applications in the early warning and rapid diagnosis of AMI and other acute diseases in emergency treatment.
Collapse
Affiliation(s)
- Wei Zhang
- College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing, 211816, PR China
| | - Jidong Jiang
- College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing, 211816, PR China
| | - Tao Liu
- State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing, 211816, PR China; College of Chemical Engineering, Nanjing Tech University, Nanjing, 211816, PR China
| | - Xun Wang
- College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing, 211816, PR China
| | - Wei Zhang
- State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing, 211816, PR China; Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, PR China
| | - Yiqing Wang
- College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing, 211816, PR China; State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing, 211816, PR China.
| | - Zhenyu Chu
- State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing, 211816, PR China; College of Chemical Engineering, Nanjing Tech University, Nanjing, 211816, PR China
| | - Wanqin Jin
- State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing, 211816, PR China; College of Chemical Engineering, Nanjing Tech University, Nanjing, 211816, PR China.
| |
Collapse
|
3
|
Xie S, Liang S, Tian L, Ding G, He M, Li H, Yang H. Electrochemical aptasensor based on DNA-templated copper nanoparticles and RecJf exonuclease-assisted target recycling for lipopolysaccharide detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:396-402. [PMID: 38131415 DOI: 10.1039/d3ay01638b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
An electrochemical aptasensor for detecting lipopolysaccharides (LPS) was fabricated based on DNA-templated copper nanoparticles (DNA-CuNPs) and RecJf exonuclease-assisted target recycling. The DNA-CuNPs were synthesized on a double-stranded DNA template generated through the hybridization of the LPS aptamer and its complementary chain (cDNA). In the absence of LPS, the CuNPs were synthesized on DNA double-strands, and a strong readout corresponding to the CuNPs was achieved at 0.10 V (vs. SCE). In the presence of LPS, the fabricated aptamer could detach from the DNA double-strand to form a complex with LPS, disrupting the template for the synthesis of CuNPs on the electrode. Meanwhile, RecJf exonuclease could hydrolyze the cDNA together with this single-stranded aptamer, releasing the LPS for the next round of aptamer binding, thereby enabling target recycling amplification. As a result, the electrochemical signal decreased and could be used to indicate the LPS content. The fabricated electrochemical aptasensor exhibited an extensive dynamic working range of 0.01 pg mL-1 to 100 ng mL-1, and its detection limit was 6.8 fg mL-1. The aptasensor also exhibited high selectivity and excellent reproducibility. Moreover, the proposed aptasensor could be used in practical applications for the detection of LPS in human serum samples.
Collapse
Affiliation(s)
- Shunbi Xie
- Chongqing Key Laboratory of Environmental Materials and Remediation Technologies, College of Chemistry & Environmental Engineering (Chongqing University of Arts and Sciences), Chongqing 402160, P. R. China.
| | - Shuting Liang
- Chongqing Key Laboratory of Environmental Materials and Remediation Technologies, College of Chemistry & Environmental Engineering (Chongqing University of Arts and Sciences), Chongqing 402160, P. R. China.
| | - Liangliang Tian
- School of Electronic Information and Electrical Engineering (Chongqing University of Arts and Sciences), Chongqing 402160, P. R. China
| | - Ge Ding
- Chongqing Key Laboratory of Environmental Materials and Remediation Technologies, College of Chemistry & Environmental Engineering (Chongqing University of Arts and Sciences), Chongqing 402160, P. R. China.
| | - Meiting He
- Chongqing Key Laboratory of Environmental Materials and Remediation Technologies, College of Chemistry & Environmental Engineering (Chongqing University of Arts and Sciences), Chongqing 402160, P. R. China.
| | - Haojie Li
- Chongqing Key Laboratory of Environmental Materials and Remediation Technologies, College of Chemistry & Environmental Engineering (Chongqing University of Arts and Sciences), Chongqing 402160, P. R. China.
| | - Heshan Yang
- Chongqing Key Laboratory of Environmental Materials and Remediation Technologies, College of Chemistry & Environmental Engineering (Chongqing University of Arts and Sciences), Chongqing 402160, P. R. China.
| |
Collapse
|
4
|
Aptamer-functionalized capacitive biosensors. Biosens Bioelectron 2023; 224:115014. [PMID: 36628826 DOI: 10.1016/j.bios.2022.115014] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 11/17/2022] [Accepted: 12/13/2022] [Indexed: 12/25/2022]
Abstract
The growing use of aptamers as target recognition elements in label-free biosensing necessitates corresponding transducers that can be used in relevant environments. While popular in many fields, capacitive sensors have seen relatively little, but growing use in conjunction with aptamers for sensing diverse targets. Few reports have shown physiologically relevant sensitivity in laboratory conditions and a cohesive picture on how target capture modifies the measured capacitance has been lacking. In this review, we assess the current state of the field in three areas: small molecule, protein, and cell sensing. We critically analyze the proposed hypotheses on how aptamer-target capture modifies the capacitance, as many mechanistic postulations appear to conflict between published works. As the field matures, we encourage future works to investigate individual aptamer-target interactions and to interrogate the physical mechanisms leading to measured changes in capacitance. To this point, we provide recommendations on best practices for developing aptasensors with a particular focus on considerations for biosensing in clinical settings.
Collapse
|
5
|
Lin X, Jiang Y, Wu JJ, Eda S, Wan N. An alternating current electrokinetics biosensor for rapid on-site serological screening of Taenia solium cysticercosis infection. Mikrochim Acta 2022; 189:476. [DOI: 10.1007/s00604-022-05575-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Accepted: 11/09/2022] [Indexed: 11/27/2022]
|
6
|
A novel labeled and label-free dual electrochemical detection of endotoxin based on aptamer-conjugated magnetic reduced graphene oxide-gold nanocomposite. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116116] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
7
|
Qi H, Huang X, Wu J, Zhang J, Wang F, Qu H, Zheng L. A disposable aptasensor based on a gold-plated coplanar electrode array for on-site and real-time determination of Cu 2. Anal Chim Acta 2021; 1183:338991. [PMID: 34627507 DOI: 10.1016/j.aca.2021.338991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 08/05/2021] [Accepted: 08/07/2021] [Indexed: 11/25/2022]
Abstract
Copper ion (Cu2+) is an important cofactor for many enzymes in human body. Either excessive or deficient Cu2+ in the body may cause serious dysfunctions and diseases. So sensitive determination of Cu2+ in environmental samples is of more significance for evaluation and control of Cu2+ intake. Based on a low-cost gold-plated coplanar electrode array, a disposable aptasensor is developed with an ultra-sensitive indicator of interfacial capacitance. Modified with a specially isolated DNA aptamer for Cu2+, this sensor achieves a high selectivity of 1207: 1 against non-target ions. To realize real-time response, alternating-current electrothermal effect is integrated into the capacitance measuring process to efficiently enrich the trace Cu2+. This sensor reaches a limit of detection of 2.97 fM, with a linear range from 5.0 fM to 50 pM. The response time is only 15 s, which can meet the real-time detection requirement. On-site test of practical samples is also realized using the disposable sensor combined with a handheld inductance/capacitance/resistance meter. This sensor with its portable test system provides a cost-efficient solution for on-site, real-time and sensitive detection of Cu2+, showing great application value in environment monitoring.
Collapse
Affiliation(s)
- Haochen Qi
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, 325035, China; School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei, 230009, China
| | - Xiaofan Huang
- School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei, 230009, China
| | - Jayne Wu
- Department of Electrical Engineering and Computer Science, The University of Tennessee, Knoxville, TN, 37996, USA.
| | - Jian Zhang
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, 325035, China; School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei, 230009, China.
| | - Fei Wang
- Beijing Smartchip Microelectronics Technology Company Limited, Beijing, 102200, China
| | - Hao Qu
- School of Food and Biological Engineering, Hefei University of Technology, Hefei, 230009, China
| | - Lei Zheng
- School of Food and Biological Engineering, Hefei University of Technology, Hefei, 230009, China.
| |
Collapse
|
8
|
Cheng C, Wu JJ, Chen J. A Sensitive and Specific Genomic RNA Sensor for Point-of-Care Screening of Zika Virus from Serum. Anal Chem 2021; 93:11379-11387. [PMID: 34378378 DOI: 10.1021/acs.analchem.0c05415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
This work presents a sensitive and specific single-step RNA sensor for Zika virus (ZIKV) in serum. Using AC electrokinetics (ACEK)-enhanced capacitive sensing technology, ZIKV genomic RNA (gRNA) can be directly detected from serum. The sensors are interdigitated electrodes modified with oligonucleotide probes complementary to the conserved regions of ZIKV gRNA. The ACEK capacitive sensing applies an optimized AC excitation signal over the sensor, which induces ACEK microfluidic enrichment of analytes and also simultaneously performs real-time monitoring of hybridization of ZIKV gRNA on the sensor surface. Hence, the sensing procedures are simple with rapid turn-around time and good specificity and sensitivity. A series of experiments are conducted to optimize the sensor performance. The performance of the sensor is investigated for three different probes, two functionalization buffers, and different hybridization buffers. With the optimized sensing protocol, this method can detect spiked ZIKV gRNA from human serum within 30 s and reach a limit of detection of 78.8 copies/μL in analytical samples and as low as 287.5 copies/μL in neat serum. The sensors can successfully differentiate between the RNAs of the ZIKV and dengue virus, two viruses with similar transmission paths and symptoms. The sensor is simple to use and requires no labeling or sophisticated process typically involved in a polymerase chain reaction, hybridization chain reaction, or nucleic acid sequence-based amplification.
Collapse
Affiliation(s)
- Cheng Cheng
- School of Engineering and Computer Science, Morehead State University, 150 University Blvd., Morehead, Kentucky 40351, United States.,Department of Electrical Engineering and Computer Science, The University of Tennessee, 1520 Middle Drive, Knoxville, Tennessee 37996, United States
| | - Jie Jayne Wu
- Department of Electrical Engineering and Computer Science, The University of Tennessee, 1520 Middle Drive, Knoxville, Tennessee 37996, United States
| | - Jiangang Chen
- Department of Public Health, The University of Tennessee, 1914 Andy Holt Avenue, Knoxville, Tennessee 37996, United States
| |
Collapse
|
9
|
Qaanei M, Taheri RA, Eskandari K. Electrochemical aptasensor for Escherichia coli O157:H7 bacteria detection using a nanocomposite of reduced graphene oxide, gold nanoparticles and polyvinyl alcohol. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:3101-3109. [PMID: 34156042 DOI: 10.1039/d1ay00563d] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In recent years, public attention has drawn to food safety due to the constant outbreaks of foodborne diseases; subsequently, to control and prevent this group of diseases, early screening of foodborne pathogens has become significant. In this study, a new aptamer-based electrochemical sensor was proposed to detect Escherichia coli O157:H7 (E. coli), one of the most threatening bacterial pathogens, using nanoparticles-modified glassy carbon electrode. Firstly, the electrode was coated with a reduced graphene oxide-poly(vinyl alcohol) and gold nanoparticles nanocomposite (AuNPs/rGO-PVA/GCE) to increase the electrode surface area and consequently raise the sensor sensitivity. Afterwards, to enhance the selectivity of the modified electrode, aptamers were attached to the surface of the prepared electrode. The prepared electrode was characterized using energy-dispersive spectroscopy, field-emission scanning electron microscopy, atomic force microscopy, Fourier-transform infrared spectroscopy, and electrochemical impedance spectroscopy. The relationship of the E. coli concentration and the peak current in the range from 9.2 CFU mL-1 to 9.2 × 108 CFU mL-1 was linear, and the limit of detection was calculated as 9.34 CFU mL-1. The suitability of the proposed sensor for real sample measurements was investigated by recovery studies in tap water, milk, and meat samples. The results showed that the biosensor and traditional culture counting methods are equally sensitive for detecting E. coli.
Collapse
Affiliation(s)
- Masood Qaanei
- Nanobiotechnology Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| | | | | |
Collapse
|
10
|
Rapid and Sensitive Detection of miRNA Based on AC Electrokinetic Capacitive Sensing for Point-of-Care Applications. SENSORS 2021; 21:s21123985. [PMID: 34207808 PMCID: PMC8226656 DOI: 10.3390/s21123985] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 05/25/2021] [Accepted: 06/03/2021] [Indexed: 12/13/2022]
Abstract
A sensitive and efficient method for microRNAs (miRNAs) detection is strongly desired by clinicians and, in recent years, the search for such a method has drawn much attention. There has been significant interest in using miRNA as biomarkers for multiple diseases and conditions in clinical diagnostics. Presently, most miRNA detection methods suffer from drawbacks, e.g., low sensitivity, long assay time, expensive equipment, trained personnel, or unsuitability for point-of-care. New methodologies are needed to overcome these limitations to allow rapid, sensitive, low-cost, easy-to-use, and portable methods for miRNA detection at the point of care. In this work, to overcome these shortcomings, we integrated capacitive sensing and alternating current electrokinetic effects to detect specific miRNA-16b molecules, as a model, with the limit of detection reaching 1.0 femto molar (fM) levels. The specificity of the sensor was verified by testing miRNA-25, which has the same length as miRNA-16b. The sensor we developed demonstrated significant improvements in sensitivity, response time and cost over other miRNA detection methods, and has application potential at point-of-care.
Collapse
|
11
|
Zhang J, Fang X, Mao Y, Qi H, Wu J, Liu X, You F, Zhao W, Chen Y, Zheng L. Real-time, selective, and low-cost detection of trace level SARS-CoV-2 spike-protein for cold-chain food quarantine. NPJ Sci Food 2021; 5:12. [PMID: 34075052 PMCID: PMC8357935 DOI: 10.1038/s41538-021-00094-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 04/06/2021] [Indexed: 02/08/2023] Open
Abstract
Due to the friendly temperature for virus survival, SARS-CoV-2 is frequently found in cold-chain foods, posing a serious threat to public health. Utilizing an interdigitated microelectrode chip modified with an antibody probe and integrating dielectrophoresis enrichment with interfacial capacitance sensing, a strategy is presented for the detection of trace level spike-protein from SARS-CoV-2. It achieves a limit of detection as low as 2.29 × 10-6 ng/mL in 20 s, with a wide linear range of 10-5-10-1 ng/mL and a selectivity of 234:1. The cost for a single test can be controlled to ~1 dollar. This strategy provides a competitive solution for real-time, sensitive, selective, and large-scale application in cold-chain food quarantine.
Collapse
Affiliation(s)
- Jian Zhang
- School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei, China.,School of Food and Biological Engineering, Hefei University of Technology, Hefei, China
| | - Xin Fang
- School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei, China
| | - Yu Mao
- School of Food and Biological Engineering, Hefei University of Technology, Hefei, China
| | - Haochen Qi
- School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei, China.
| | - Jayne Wu
- Department of Electrical Engineering and Computer Science, The University of Tennessee, Knoxville, TN, USA.
| | - Xiaoru Liu
- School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei, China
| | - Fangshuo You
- School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei, China
| | - Wenci Zhao
- School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei, China
| | - Ying Chen
- Agro-product Safety Research Centre, Chinese Academy of Inspection and Quarantine, Beijing, China
| | - Lei Zheng
- School of Food and Biological Engineering, Hefei University of Technology, Hefei, China.
| |
Collapse
|
12
|
An on-site, highly specific immunosensor for Escherichia coli detection in field milk samples from mastitis-affected dairy cattle. Biosens Bioelectron 2020; 165:112366. [DOI: 10.1016/j.bios.2020.112366] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 05/16/2020] [Accepted: 06/04/2020] [Indexed: 12/16/2022]
|
13
|
An interdigitated microelectrode based aptasensor for real-time and ultratrace detection of four organophosphorus pesticides. Biosens Bioelectron 2019; 150:111879. [PMID: 31767346 DOI: 10.1016/j.bios.2019.111879] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/11/2019] [Accepted: 11/12/2019] [Indexed: 11/20/2022]
Abstract
With increasing industrialization of food production, residues of organophosphorus pesticides (OPs) are more frequently found in the environment including rivers, lakes and soils. Extended exposure to OPs, even at a level below 1 nM, may lead to liver and central nervous system damages in humans and animals, while existing detection methods are not sensitive enough to detect OPs at trace levels. We presented a simple-to-use aptasensor to rapidly detect broad-spectrum OPs with high sensitivity. DNA aptamer was modified on the surface of a micro interdigitated electrode chip, and AC electrokinetics was employed to accelerate the binding of OP molecules to the aptamer probe. The sensing strategy directly measured the interfacial capacitance whose change rate was adopted as a quantitative indicator of recognition events, with a sample to result detection time of 30 s. This aptasensor had a wide linear range of (fM ~ nM), and the detection limit reached (0.24-1.67) fM for four highly-toxic OPs, with good specificity. It still showed good activity after being stored in non-refrigerated environment for at least 14 days. This aptasensor as well as the detection method offer a promising solution for on-site and real-time sensitive OP detection.
Collapse
|
14
|
Wen LX, Lv JJ, Chen L, Li SB, Mou XJ, Xu Y. A fluorescent probe composed of quantum dot labeled aptamer and graphene oxide for the determination of the lipopolysaccharide endotoxin. Mikrochim Acta 2019; 186:122. [PMID: 30666423 DOI: 10.1007/s00604-018-3218-3] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Accepted: 12/28/2018] [Indexed: 01/28/2023]
Abstract
Endotoxins are complex lipopolysaccharides (LPS) and key components of the outer cell membrane of Gram-negative bacteria. The authors report on a fluorescent aptamer-based probe for the determination of LPS of Gram-negative bacteria. An aptamer against LPS was fluorescently labeled with CdSe/ZnS quantum dots. Its emission is quenched on addition of graphene oxide (GO). On addition of LPS, the aptamer binds LPS and GO is released. This results in the recovery of fluorescence, typically measured at excitation/emission wavelengths of 495/543 nm. The probe responds to LPS in the 10-500 ng·mL-1 concentration range, and the detection limit is 8.7 ng·mL-1. It can be used for selective detection of LPS from different Gram-negative bacteria, in the presence of biological interferents. Graphical abstract Schematic presentation of a green fluorescent probe comprised of an aptamer labelled with CdSe/ZnS quantum dots and of graphene oxide. Lipopolysaccharides bind to the aptamer and release graphene oxide to result in fluorescence recovery, which is measured at an emission wavelength 543 nm.
Collapse
Affiliation(s)
- Lu-Xin Wen
- Key Disciplines Lab of Novel Micro-nano Devices and System Technology, Chongqing University, Chongqing, 400030, China
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing, 400030, China
- National Center for International Research of Micro/Nano-System and New Material Technology, Chongqing University, Chongqing, 400030, China
| | - Jun-Jiang Lv
- Key Disciplines Lab of Novel Micro-nano Devices and System Technology, Chongqing University, Chongqing, 400030, China.
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing, 400030, China.
- Collaborative Innovation Center for Brain Science, Chongqing University, Chongqing, 400030, People's Republic of China.
| | - Li Chen
- Key Disciplines Lab of Novel Micro-nano Devices and System Technology, Chongqing University, Chongqing, 400030, China
- National Center for International Research of Micro/Nano-System and New Material Technology, Chongqing University, Chongqing, 400030, China
| | - Shun-Bo Li
- Key Disciplines Lab of Novel Micro-nano Devices and System Technology, Chongqing University, Chongqing, 400030, China
- National Center for International Research of Micro/Nano-System and New Material Technology, Chongqing University, Chongqing, 400030, China
| | - Xiao-Jing Mou
- Key Disciplines Lab of Novel Micro-nano Devices and System Technology, Chongqing University, Chongqing, 400030, China
- National Center for International Research of Micro/Nano-System and New Material Technology, Chongqing University, Chongqing, 400030, China
| | - Yi Xu
- Key Disciplines Lab of Novel Micro-nano Devices and System Technology, Chongqing University, Chongqing, 400030, China.
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing, 400030, China.
- National Center for International Research of Micro/Nano-System and New Material Technology, Chongqing University, Chongqing, 400030, China.
- Collaborative Innovation Center for Brain Science, Chongqing University, Chongqing, 400030, People's Republic of China.
| |
Collapse
|