1
|
Wang A, Qi W, Gao T, Tang X. Molecular Contrast Optical Coherence Tomography and Its Applications in Medicine. Int J Mol Sci 2022; 23:ijms23063038. [PMID: 35328454 PMCID: PMC8949853 DOI: 10.3390/ijms23063038] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 03/05/2022] [Accepted: 03/08/2022] [Indexed: 12/28/2022] Open
Abstract
The growing need to understand the molecular mechanisms of diseases has prompted the revolution in molecular imaging techniques along with nanomedicine development. Conventional optical coherence tomography (OCT) is a low-cost in vivo imaging modality that provides unique high spatial and temporal resolution anatomic images but little molecular information. However, given the widespread adoption of OCT in research and clinical practice, its robust molecular imaging extensions are strongly desired to combine with anatomical images. A range of relevant approaches has been reported already. In this article, we review the recent advances of molecular contrast OCT imaging techniques, the corresponding contrast agents, especially the nanoparticle-based ones, and their applications. We also summarize the properties, design criteria, merit, and demerit of those contrast agents. In the end, the prospects and challenges for further research and development in this field are outlined.
Collapse
|
2
|
Ma Z, Liu X, Yin B, Zhao Y, Liu J, Yu Y, Wang Y. Common-path-based device for magnetomotive OCT noise reduction. APPLIED OPTICS 2020; 59:1431-1437. [PMID: 32225400 DOI: 10.1364/ao.377118] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 12/25/2019] [Indexed: 06/10/2023]
Abstract
Magnetomotive optical coherence tomography (MMOCT) is a promising imaging method for noninvasive three-dimensional tracking of magnetic nanoparticle (MNP) motions in target tissues or organs. The external B-field is the driving force that provides MMOCT contrast. However, B-field modulation also introduces modulation noise, thereby decreasing the quality of the MMOCT image. In this paper, a common-path-based device is designed for modulation noise reduction. The device is capable of adjusting interference distance, reference light intensity, and imaging position (X-Y translation). The sensitivity of the MMOCT is increased by ∼20 times with the new device. Using the proposed device, the distribution of MNPs injected in zebrafish was imaged.
Collapse
|
3
|
Thapa D, Levy BE, Marks DL, Oldenburg AL. Inversion of displacement fields to quantify the magnetic particle distribution in homogeneous elastic media from magnetomotive ultrasound. Phys Med Biol 2019; 64:125019. [PMID: 31051477 DOI: 10.1088/1361-6560/ab1f2b] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Magnetomotive ultrasound (MMUS) contrasts superparamagnetic iron-oxide nanoparticles (SPIOs) that undergo submicrometer-scale displacements in response to a magnetic gradient force applied to an imaging sample. Typically, MMUS signals are defined in a way that is proportional to the medium displacement, rendering an indirect measure of the density distribution of SPIOs embedded within. Displacement-based MMUS, however, suffers from 'halo effects' that extend into regions without SPIOs due to their inherent mechanical coupling with the medium. To reduce such effects and to provide a more accurate representation of the SPIO density distribution, we propose a model-based inversion of MMUS displacement fields by reconstructing the body force distribution. Displacement fields are modelled using the static Navier-Cauchy equation for linear, homogeneous, and isotropic media, and the body force fields are, in turn, reconstructed by minimizing a regularized least-squares error functional between the modelled and the measured displacement fields. This reconstruction, when performed on displacement fields of two tissue-mimicking phantoms with cuboidal SPIO-laden inclusions, improved the range of errors in measured heights and widths of the inclusions from 54%-282% pre-inversion to-15%-20%. Likewise, the post-inversion contrast to noise ratios (CNRs) of the images were significantly larger than displacement-derived CNRs alone (p = 0.0078, Wilcoxon signed rank test). Qualitatively, it was found that inversion ameliorates halo effects and increases overall detectability of the inclusion. These findings highlight the utility of model-based inversion as a tool for both signal processing and accurate characterization of the number density distribution of SPIOs in magnetomotive imaging.
Collapse
Affiliation(s)
- Diwash Thapa
- Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
| | | | | | | |
Collapse
|
4
|
Marjanovic M, Nguyen FT, Ahmad A, Huang PC, Suslick KS, Boppart SA. Characterization of Magnetic Nanoparticle-Seeded Microspheres for Magnetomotive and Multimodal Imaging. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2019; 25:7101314. [PMID: 30880897 PMCID: PMC6413528 DOI: 10.1109/jstqe.2018.2856582] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Magnetic iron-oxide nanoparticles have been developed as contrast agents in magnetic resonance imaging (MRI) and as therapeutic agents in magnetic hyperthermia. They have also recently been demonstrated as contrast and elastography agents in magnetomotive optical coherence tomography and elastography (MM-OCT and MM-OCE, respectively). Protein-shell microspheres containing suspensions of these magnetic nanoparticles in lipid cores, and with functionalized outer shells for specific targeting, have also been demonstrated as efficient contrast agents for imaging modalities such as MM-OCT and MRI, and can be easily modified for other modalities such as ultrasound, fluorescence, and luminescence imaging. By leveraging the benefits of these various imaging modalities with the use of only a single agent, a magnetic microsphere, it becomes possible to use a widefield imaging method (such as MRI or small animal fluorescence imaging) to initially locate the agent, and then use MM-OCT to obtain dynamic contrast images with cellular level morphological resolution. In addition to multimodal contrast-enhanced imaging, these microspheres could serve as drug carriers for targeted delivery under image guidance. Although the preparation and surface modifications of protein microspheres containing iron oxide nanoparticles has been previously described and feasibility studies conducted, many questions regarding their production and properties remain. Since the use of multifunctional microspheres could have high clinical relevance, here we report a detailed characterization of their properties and behavior in different environments to highlight their versatility. The work presented here is an effort for the development and optimization of nanoparticle-based microspheres as multi-modal contrast agents that can bridge imaging modalities on different size scales, especially for their use in MM-OCT and MRI imaging.
Collapse
Affiliation(s)
- Marina Marjanovic
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA
| | - Freddy T Nguyen
- University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA. He is now with the Massachusetts Institute of Technology, Cambridge, MA, 02139 USA
| | - Adeel Ahmad
- University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA. He is now with Texas Instruments.
| | - Pin-Chieh Huang
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA
| | - Kenneth S Suslick
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA
| | - Stephen A Boppart
- Department of Electrical and Computer Engineering and Bioengineering, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA (phone: 217-244-7479; fax: 217-333-5833; )
| |
Collapse
|
5
|
Bouma BE, Villiger M, Otsuka K, Oh WY. Intravascular optical coherence tomography [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:2660-2686. [PMID: 28663897 PMCID: PMC5480504 DOI: 10.1364/boe.8.002660] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Revised: 04/10/2017] [Accepted: 04/11/2017] [Indexed: 05/03/2023]
Abstract
Shortly after the first demonstration of optical coherence tomography for imaging the microstructure of the human eye, work began on developing systems and catheters suitable for intravascular imaging in order to diagnose and investigate atherosclerosis and potentially to monitor therapy. This review covers the driving considerations of the clinical application and its constraints, the major engineering milestones that enabled the current, high-performance commercial imaging systems, the key studies that laid the groundwork for image interpretation, and the clinical research that traces intravascular optical coherence tomography (OCT) from early human pilot studies to current clinical trials.
Collapse
Affiliation(s)
- Brett E Bouma
- Harvard Medical School and Massachusetts General Hospital, Boston, MA 02171, USA
- Institute for Medical Engineering and Science, Cambridge, MA, 02139, USA
| | - Martin Villiger
- Harvard Medical School and Massachusetts General Hospital, Boston, MA 02171, USA
| | - Kenichiro Otsuka
- Harvard Medical School and Massachusetts General Hospital, Boston, MA 02171, USA
| | - Wang-Yuhl Oh
- Department of Mechanical Engineering, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon, South Korea
- KI for Health Science and Technology, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon, South Korea
| |
Collapse
|
6
|
Larin KV, Sampson DD. Optical coherence elastography - OCT at work in tissue biomechanics [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:1172-1202. [PMID: 28271011 PMCID: PMC5330567 DOI: 10.1364/boe.8.001172] [Citation(s) in RCA: 217] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Revised: 01/18/2017] [Accepted: 01/19/2017] [Indexed: 05/18/2023]
Abstract
Optical coherence elastography (OCE), as the use of OCT to perform elastography has come to be known, began in 1998, around ten years after the rest of the field of elastography - the use of imaging to deduce mechanical properties of tissues. After a slow start, the maturation of OCT technology in the early to mid 2000s has underpinned a recent acceleration in the field. With more than 20 papers published in 2015, and more than 25 in 2016, OCE is growing fast, but still small compared to the companion fields of cell mechanics research methods, and medical elastography. In this review, we describe the early developments in OCE, and the factors that led to the current acceleration. Much of our attention is on the key recent advances, with a strong emphasis on future prospects, which are exceptionally bright.
Collapse
Affiliation(s)
- Kirill V Larin
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Blvd., Houston, Texas 77204-5060, USA; Department of Molecular Physiology and Biophysics, Baylor College of Medicine, 1 Baylor Plaza, Houston, Texas 77030, USA;
| | - David D Sampson
- Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia; Centre for Microscopy, Characterisation & Analysis, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia;
| |
Collapse
|
7
|
Huang PC, Pande P, Ahmad A, Marjanovic M, Spillman DR, Odintsov B, Boppart SA. Magnetomotive Optical Coherence Elastography for Magnetic Hyperthermia Dosimetry Based on Dynamic Tissue Biomechanics. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2016; 22:6802816. [PMID: 28163565 PMCID: PMC5289667 DOI: 10.1109/jstqe.2015.2505147] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Magnetic nanoparticles (MNPs) have been used in many diagnostic and therapeutic biomedical applications over the past few decades to enhance imaging contrast, steer drugs to targets, and treat tumors via hyperthermia. Optical coherence tomography (OCT) is an optical biomedical imaging modality that relies on the detection of backscattered light to generate high-resolution cross-sectional images of biological tissue. MNPs have been utilized as imaging contrast and perturbative mechanical agents in OCT in techniques called magnetomotive OCT (MM-OCT) and magnetomotive elastography (MM-OCE), respectively. MNPs have also been independently used for magnetic hyperthermia treatments, enabling therapeutic functions such as killing tumor cells. It is well known that the localized tissue heating during hyperthermia treatments result in a change in the biomechanical properties of the tissue. Therefore, we propose a novel dosimetric technique for hyperthermia treatment based on the viscoelasticity change detected by MM-OCE, further enabling the theranostic function of MNPs. In this paper, we first review the basic principles and applications of MM-OCT, MM-OCE, and magnetic hyperthermia, and present new preliminary results supporting the concept of MM-OCE-based hyperthermia dosimetry.
Collapse
Affiliation(s)
- Pin-Chieh Huang
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, and the Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Paritosh Pande
- Biophotonics Imaging Laboratory and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Adeel Ahmad
- Biophotonics Imaging Laboratory and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Marina Marjanovic
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, and the Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Darold R Spillman
- Biophotonics Imaging Laboratory and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Boris Odintsov
- Biophotonics Imaging Laboratory and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Stephen A Boppart
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, and the Departments of Electrical and Computer Engineering, Bioengineering, and Medicine, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA (phone: 217-333-8598; fax: 217-333-5833; )
| |
Collapse
|