1
|
Bandyopadhyay A, Mitra I, Goodman SB, Kumar M, Bose S. Improving Biocompatibility for Next Generation of Metallic Implants. PROGRESS IN MATERIALS SCIENCE 2023; 133:101053. [PMID: 36686623 PMCID: PMC9851385 DOI: 10.1016/j.pmatsci.2022.101053] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The increasing need for joint replacement surgeries, musculoskeletal repairs, and orthodontics worldwide prompts emerging technologies to evolve with healthcare's changing landscape. Metallic orthopaedic materials have a shared application history with the aerospace industry, making them only partly efficient in the biomedical domain. However, suitability of metallic materials in bone tissue replacements and regenerative therapies remains unchallenged due to their superior mechanical properties, eventhough they are not perfectly biocompatible. Therefore, exploring ways to improve biocompatibility is the most critical step toward designing the next generation of metallic biomaterials. This review discusses methods of improving biocompatibility of metals used in biomedical devices using surface modification, bulk modification, and incorporation of biologics. Our investigation spans multiple length scales, from bulk metals to the effect of microporosities, surface nanoarchitecture, and biomolecules such as DNA incorporation for enhanced biological response in metallic materials. We examine recent technologies such as 3D printing in alloy design and storing surface charge on nanoarchitecture surfaces, metal-on-metal, and ceramic-on-metal coatings to present a coherent and comprehensive understanding of the subject. Finally, we consider the advantages and challenges of metallic biomaterials and identify future directions.
Collapse
Affiliation(s)
- Amit Bandyopadhyay
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920
| | - Indranath Mitra
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920
| | - Stuart B. Goodman
- Department of Orthopedic Surgery, Stanford University Medical Center, Redwood City, CA 94063
| | | | - Susmita Bose
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920
| |
Collapse
|
2
|
Yasenchuk Y, Marchenko E, Gunther V, Radkevich A, Kokorev O, Gunther S, Baigonakova G, Hodorenko V, Chekalkin T, Kang JH, Weiss S, Obrosov A. Biocompatibility and Clinical Application of Porous TiNi Alloys Made by Self-Propagating High-Temperature Synthesis (SHS). MATERIALS (BASEL, SWITZERLAND) 2019; 12:E2405. [PMID: 31357702 PMCID: PMC6696327 DOI: 10.3390/ma12152405] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 07/23/2019] [Accepted: 07/26/2019] [Indexed: 11/16/2022]
Abstract
Porous TiNi alloys fabricated by self-propagating high-temperature synthesis (SHS) are biomaterials designed for medical application in substituting tissue lesions and they were clinically deployed more than 30 years ago. The SHS process, as a very fast and economically justified route of powder metallurgy, has distinctive features which impart special attributes to the resultant implant, facilitating its integration in terms of bio-mechanical/chemical compatibility. On the phenomenological level, the fact of high biocompatibility of porous SHS TiNi (PTN) material in vivo has been recognized and is not in dispute presently, but the rationale is somewhat disputable. The features of the SHS TiNi process led to a multifarious intermetallic Ti4Ni2(O,N,C)-based constituents in the amorphous-nanocrystalline superficial layer which entirely conceals the matrix and enhances the corrosion resistance of the unwrought alloy. In the current article, we briefly explore issues of the high biocompatibility level on which additional studies could be carried out, as well as recent progress and key fields of clinical application, yet allowing innovative solutions.
Collapse
Affiliation(s)
- Yuri Yasenchuk
- Research Institute of Medical Materials, Tomsk State University, Tomsk 634045, Russia
| | - Ekaterina Marchenko
- Research Institute of Medical Materials, Tomsk State University, Tomsk 634045, Russia
| | - Victor Gunther
- Research Institute of Medical Materials, Tomsk State University, Tomsk 634045, Russia
| | - Andrey Radkevich
- Research Institute of Medical Problems of the North, Siberian Branch of the Russian Academy of Sciences, Krasnoyarsk 660017, Russia
| | - Oleg Kokorev
- Research Institute of Medical Materials, Tomsk State University, Tomsk 634045, Russia
| | - Sergey Gunther
- Research Institute of Medical Materials, Tomsk State University, Tomsk 634045, Russia
| | - Gulsharat Baigonakova
- Research Institute of Medical Materials, Tomsk State University, Tomsk 634045, Russia
| | - Valentina Hodorenko
- Research Institute of Medical Materials, Tomsk State University, Tomsk 634045, Russia
| | - Timofey Chekalkin
- Research Institute of Medical Materials, Tomsk State University, Tomsk 634045, Russia.
- Kang and Park Medical Co., R&D Center, Ochang 28119, Korea.
| | - Ji-Hoon Kang
- Kang and Park Medical Co., R&D Center, Ochang 28119, Korea
| | - Sabine Weiss
- Department of Physical Metallurgy and Materials Technology, Brandenburg University of Technology, 03044 Cottbus, Germany
| | - Aleksei Obrosov
- Department of Physical Metallurgy and Materials Technology, Brandenburg University of Technology, 03044 Cottbus, Germany
| |
Collapse
|
3
|
A randomized double-blinded clinical trial to evaluate the safety and efficacy of a novel superelastic nickel-titanium spinal rod in adolescent idiopathic scoliosis: 5-year follow-up. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2017; 27:327-339. [PMID: 28776134 DOI: 10.1007/s00586-017-5245-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2016] [Revised: 07/12/2017] [Accepted: 07/27/2017] [Indexed: 10/19/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of a superelastic shape-memory alloy (SNT) rod used in the treatment of adolescent idiopathic scoliosis (AIS). METHODS AIS Patients with Lenke 1 curves undergoing fusion surgery were randomized (1:1) at the time of surgery to receive either the SNT or a conventional titanium alloy (CTA) rod. Radiographs were obtained preoperatively and postoperatively up to 5 years of follow-up. Parameters assessed included coronal and sagittal Cobb angles, and overall truncal and shoulder balance. Sagittal profiles were subcategorized into Types A (<20°), B (20-40°), and C (>40°). RESULTS Twenty-four patients with mean age of 15 years were recruited. A total of 87.0% of subjects were followed up till postoperative 5 years, but all patients had minimum 2 years of follow-up. The fulcrum-bending correction index for the SNT group was 113% at postoperative day 4 and 127% at half-year, while the CTA group was 112% at postoperative day 4 and only 106% at half-year. In terms of sagittal profile, the SNT group moved toward type B profile at half-year follow-up with a mean correction of 7.6°, while no significant change was observed in the CTA group (-0.7°). Nickel levels remained normal, and there were no complications. CONCLUSIONS This is the first randomized clinical trial of a novel SNT rod for treating patients with AIS, noting it to be safe and has potential to gradually correct scoliosis over time. This study serves as a pilot and platform to properly power future large-scale studies to demonstrate efficacy and superiority.
Collapse
|
4
|
Prasad K, Bazaka O, Chua M, Rochford M, Fedrick L, Spoor J, Symes R, Tieppo M, Collins C, Cao A, Markwell D, Ostrikov KK, Bazaka K. Metallic Biomaterials: Current Challenges and Opportunities. MATERIALS (BASEL, SWITZERLAND) 2017; 10:E884. [PMID: 28773240 PMCID: PMC5578250 DOI: 10.3390/ma10080884] [Citation(s) in RCA: 199] [Impact Index Per Article: 28.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Revised: 07/14/2017] [Accepted: 07/25/2017] [Indexed: 11/16/2022]
Abstract
Metallic biomaterials are engineered systems designed to provide internal support to biological tissues and they are being used largely in joint replacements, dental implants, orthopaedic fixations and stents. Higher biomaterial usage is associated with an increased incidence of implant-related complications due to poor implant integration, inflammation, mechanical instability, necrosis and infections, and associated prolonged patient care, pain and loss of function. In this review, we will briefly explore major representatives of metallic biomaterials along with the key existing and emerging strategies for surface and bulk modification used to improve biointegration, mechanical strength and flexibility of biometals, and discuss their compatibility with the concept of 3D printing.
Collapse
Affiliation(s)
- Karthika Prasad
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
- CSIRO-QUT Joint Sustainable Processes and Devices Laboratory, Commonwealth Scientific and Industrial Research Organization, P.O. Box 218, Lindfield, NSW 2070, Australia.
- Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Olha Bazaka
- College of Science and Engineering, Technology and Engineering, James Cook University, Townsville, QLD 4810, Australia.
| | - Ming Chua
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Madison Rochford
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Liam Fedrick
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Jordan Spoor
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Richard Symes
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Marcus Tieppo
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Cameron Collins
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Alex Cao
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - David Markwell
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Kostya Ken Ostrikov
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
- CSIRO-QUT Joint Sustainable Processes and Devices Laboratory, Commonwealth Scientific and Industrial Research Organization, P.O. Box 218, Lindfield, NSW 2070, Australia.
- Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| | - Kateryna Bazaka
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia.
- CSIRO-QUT Joint Sustainable Processes and Devices Laboratory, Commonwealth Scientific and Industrial Research Organization, P.O. Box 218, Lindfield, NSW 2070, Australia.
- Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, QLD 4000, Australia.
- College of Science and Engineering, Technology and Engineering, James Cook University, Townsville, QLD 4810, Australia.
| |
Collapse
|
5
|
Rupérez E, Manero JM, Bravo-González LA, Espinar E, Gil FJ. Development of Biomimetic NiTi Alloy: Influence of Thermo-Chemical Treatment on the Physical, Mechanical and Biological Behavior. MATERIALS 2016; 9:ma9060402. [PMID: 28773526 PMCID: PMC5456747 DOI: 10.3390/ma9060402] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Revised: 05/11/2016] [Accepted: 05/17/2016] [Indexed: 11/30/2022]
Abstract
A bioactive layer, free of nickel, has been performed for its greater acceptability and reliability in clinical applications for NiTi shape memory alloys. In the first step, a safe barrier against Ni release has been produced on the surface by means of a thicker rutile/anastase protective layer free of nickel. In the second step, a sodium alkaline titanate hydrogel, which has the ability to induce apatite formation, has been performed from oxidized surface. An improvement of host tissue–implant integration has been achieved in terms of Ni ions release and the bioactivity of the treated NiTi alloys has been corroborated with both in vitro and in vivo studies. The transformation temperatures (As, Af, Ms, and Mf), as well as the critical stresses (σβ⇔M), have been slightly changed due to this surface modification. Consequently, this fact must be taken into account in order to design new surface modification on NiTi implants.
Collapse
Affiliation(s)
- Elisa Rupérez
- Centre de Recerca Nanoenginyeria (CrnE), Departamento Ciencia de los Materiales e Ingeniería Metalúrgica, Escola Tècnica Superior d'Enginyeria Industrial de Barcelona (ETSEIB), Universidad Politécnica de Catalunya, Barcelona 08028, Spain.
| | - José María Manero
- Centre de Recerca Nanoenginyeria (CrnE), Departamento Ciencia de los Materiales e Ingeniería Metalúrgica, Escola Tècnica Superior d'Enginyeria Industrial de Barcelona (ETSEIB), Universidad Politécnica de Catalunya, Barcelona 08028, Spain.
| | | | - Eduardo Espinar
- Department of Ortodoncia, Facultad de Odontología, Universidad de Sevilla, Sevilla 41009, Spain.
| | - F J Gil
- Universidad Internacional de Cataluña, C/Immaculada 22, Barcelona 08195, Spain.
| |
Collapse
|
6
|
Li J, Wang G, Geng H, Zhu H, Zhang M, Di Z, Liu X, Chu PK, Wang X. CVD Growth of Graphene on NiTi Alloy for Enhanced Biological Activity. ACS APPLIED MATERIALS & INTERFACES 2015; 7:19876-19881. [PMID: 26323051 DOI: 10.1021/acsami.5b06639] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
From the perspective of surface modification of biomaterials, graphene is very promising because of its unique physical and chemical properties. Herein, we report direct in situ fabrication of graphene on nitinol (NiTi) shape memory alloy by chemical vapor deposition (CVD) and investigate both the growth mechanism as well as surface bioactivity of the modified alloy. Growth of the graphene layer is independent of Ni but is rather correlated with the formation of the TiC phase on the surface. Graphene nucleates and grows on this carbide layer during exposure to CH4. The graphene layer is observed to promote the osteogenesis differentiation of mesenchymal stem cells and surface bioactivity. The use of graphene as a bioactive layer is a viable approach to improving the surface properties of NiTi-based dental and orthopedic implants and components.
Collapse
Affiliation(s)
- Jinhua Li
- University of Chinese Academy of Sciences , Beijing 100049, China
| | - Gang Wang
- School of Physical Science and Technology, Lanzhou University , Lanzhou 730000, China
| | - Hao Geng
- University of Chinese Academy of Sciences , Beijing 100049, China
| | | | | | | | | | - Paul K Chu
- Department of Physics and Materials Science, City University of Hong Kong , Tat Chee Avenue, Kowloon, Hong Kong China
| | | |
Collapse
|
7
|
Surface characteristics, corrosion and bioactivity of chemically treated biomedical grade NiTi alloy. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 56:417-25. [PMID: 26249609 DOI: 10.1016/j.msec.2015.06.051] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Revised: 05/26/2015] [Accepted: 06/25/2015] [Indexed: 11/22/2022]
Abstract
The surface of NiTi alloy was chemically modified using acidified ferric chloride solution and the characteristics of the alloy surface were studied from the view point of application as a bioimplant. Chemically treated NiTi was also subjected to post treatments by annealing at 400°C and passivation in nitric acid. The surface of NiTi alloy after chemical treatment developed a nanogrid structure with a combination of one dimensional channel and two dimensional network-like patterns. From SEM studies, it was found that the undulations formed after chemical treatment remained unaffected after annealing, while after passivation process the undulated surface was filled with oxides of titanium. XPS analysis revealed that the surface of passivated sample was enriched with oxides of titanium, predominantly TiO2. The influence of post treatment on the corrosion resistance of chemically treated NiTi alloy was monitored using Potentiodynamic Polarization and Electrochemical Impedance Spectroscopy (EIS) in Phosphate Buffered Saline (PBS) solution. In the chemically treated condition, NiTi alloy exhibited poor corrosion resistance due to the instability of the surface. On the other hand, the breakdown potential (0.8V) obtained was highest for the passivated samples compared to other surface treated samples. During anodic polarization, chemically treated samples displayed dissolution phenomenon which was predominantly activation controlled. But after annealing and passivation processes, the behavior of anodic polarization was typical of a diffusion controlled process which confirmed the enhanced passivity of the post treated surfaces. The total resistance, including the porous and barrier layer, was in the range of mega ohms for passivated surfaces, which could be attributed to the decrease in surface nickel content and formation of compact titanium oxide. The passivated sample displayed good bioactivity in terms of hydroxyapatite growth, noticed after 14days immersion in Hanks' solution.
Collapse
|
8
|
Effect of high-pressure torsion deformation on surface properties and biocompatibility of Ti-50.9 mol. %Ni alloys. Biointerphases 2015; 9:029007. [PMID: 24985211 DOI: 10.1116/1.4867402] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Ti-50.9 mol. %Ni was subjected to high-pressure torsion (HPT) deformation for different number of rotations (N) of 0.25, 0.5, 1, 5, and 10. The structural changes induced by HPT were analyzed using x-ray diffractometer (XRD). The surfaces of the samples before and after cell culture were characterized using x-ray photoelectron spectroscopy (XPS). The biocompatibility of the samples was evaluated based on a colony formation assay, nickel ion release, and protein adsorption behavior. XRD analysis revealed the occurrence of grain refinement, phase transformation, and amorphization in the TiNi samples by HPT deformation due to high dislocation density. The changes in chemical composition and thickness of the passive film formed on the surface observed in XPS analysis reveals improvement in the stability of the passive film by HPT deformation. The microstructural change due to the deformation was found to influence the biocompatibility behaviors of TiNi. Plating efficiency and protein adsorption were found to be higher when the samples are in stress-induced martensitic or amorphous state. HPT deformation was found to alter the surface behavior of the TiNi, which effectively reduced the Ni ion release and improved its biocompatibility.
Collapse
|
9
|
Maleki-Ghaleh H, Khalil-Allafi J, Sadeghpour-Motlagh M, Shakeri MS, Masoudfar S, Farrokhi A, Beygi Khosrowshahi Y, Nadernezhad A, Siadati MH, Javidi M, Shakiba M, Aghaie E. Effect of surface modification by nitrogen ion implantation on the electrochemical and cellular behaviors of super-elastic NiTi shape memory alloy. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2014; 25:2605-2617. [PMID: 25064465 DOI: 10.1007/s10856-014-5283-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Accepted: 07/17/2014] [Indexed: 06/03/2023]
Abstract
The aim of this investigation was to enhance the biological behavior of NiTi shape memory alloy while preserving its super-elastic behavior in order to facilitate its compatibility for application in human body. The surfaces of NiTi samples were bombarded by three different nitrogen doses. Small-angle X-ray diffraction was employed for evaluating the generated phases on the bombarded surfaces. The electrochemical behaviors of the bare and surface-modified NiTi samples were studied in simulated body fluid (SBF) using electrochemical impedance and potentio-dynamic polarization tests. Ni ion release during a 2-month period of service in the SBF environment was evaluated using atomic absorption spectrometry. The cellular behavior of nitrogen-modified samples was studied using fibroblast cells. Furthermore, the effect of surface modification on super-elasticity was investigated by tensile test. The results showed the improvement of both corrosion and biological behaviors of the modified NiTi samples. However, no significant change in the super-elasticity was observed. Samples modified at 1.4E18 ion cm(-2) showed the highest corrosion resistance and the lowest Ni ion release.
Collapse
Affiliation(s)
- H Maleki-Ghaleh
- Research Center for Advanced Materials and Mineral Processing, Faculty of Materials Engineering, Sahand University of Technology, P.O. Box: 51335-11996, Tabriz, Iran,
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Maleki-Ghaleh H, Khalil-Allafi J, Aghaie E, Siadati MH. Effect of TiO2-Ti and TiO2-TiN composite coatings on corrosion behavior of NiTi alloy. SURF INTERFACE ANAL 2014. [DOI: 10.1002/sia.5679] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- H. Maleki-Ghaleh
- Research Center for Advanced Materials and Mineral Processing, Faculty of Materials Engineering; Sahand University of Technology; Tabriz Iran
| | - J. Khalil-Allafi
- Research Center for Advanced Materials and Mineral Processing, Faculty of Materials Engineering; Sahand University of Technology; Tabriz Iran
| | - E. Aghaie
- Department of Materials Science and Engineering, Saveh Branch; Islamic Azad University; Saveh Iran
| | - M. H. Siadati
- Faculty of Materials Science and Engineering, K. N.; Toosi University of Technology; Tehran Iran
| |
Collapse
|
11
|
Fang J, Zhao J, Sun Y, Ma H, Yu X, Ma Y, Ni Y, Zheng L, Zhou Y. Biocompatibility and Antibacterial Properties of Zinc-ion Implantation on Titanium. J HARD TISSUE BIOL 2014. [DOI: 10.2485/jhtb.23.35] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
12
|
Pogrebnjak AD, Bratushka SN, Beresnev VM, Levintant-Zayonts N. Shape memory effect and superelasticity of titanium nickelide alloys implanted with high ion doses. RUSSIAN CHEMICAL REVIEWS 2013. [DOI: 10.1070/rc2013v082n12abeh004344] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
13
|
Mazilu D, Li M, Kocaturk O, Horvath KA. Self-Expanding Stent and Delivery System for Aortic Valve Replacement. J Med Device 2012; 6:410061-410069. [PMID: 23917953 DOI: 10.1115/1.4007750] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2012] [Revised: 09/14/2012] [Indexed: 11/08/2022] Open
Abstract
Currently, aortic valve replacement procedures require a sternotomy and use of cardiopulmonary bypass (CPB) to arrest the heart and provide a bloodless field in which to operate. A less invasive alternative to open heart surgery is transapical or transcatheter aortic valve replacement (TAVR), already emerging as a feasible treatment for patients with high surgical risk. The bioprosthetic valves are delivered via catheters using transarterial or transapical approaches and are implanted within diseased aortic valves. This paper reports the development of a new self-expanding stent for minimally invasive aortic valve replacement and its delivery device for the transapical approach under real-time magnetic resonance imaging (MRI) guidance. Made of nitinol, the new stent is designed to implant and embed a commercially available bioprosthetic aortic valve in aortic root. An MRI passive marker was affixed onto the stent and an MRI active marker to the delivery device. These capabilities were tested in ex vivo and in vivo experiments. Radial resistive force, chronic outward force, and the integrity of bioprosthesis on stent were measured through custom design dedicated test equipment. In vivo experimental evaluation was done using a porcine large animal model. Both ex vivo and in vivo experiment results indicate that the self-expanding stent provides adequate reinforcement of the bioprosthetic aortic valve and it is easier to implant the valve in the correct position. The orientation and positioning of the implanted valve is more precise and predictable with the help of the passive marker on stent and the active marker on delivery device. The new self-expanding nitinol stent was designed to exert a constant radial force and, therefore, a better fixation of the prosthesis in the aorta, which would result in better preservation of long-term heart function. The passive marker affixed on the stent and active marker embedded in the delivery devices helps to achieve precise orientation and positioning of the stent under MRI guidance. The design allows the stent to be retracted in the delivery device with a snaring catheter if necessary. Histopathology reports reveal that the stent is biocompatible and fully functional. All the stented bioprosthesis appeared to be properly seated in the aortic root.
Collapse
|
14
|
Zhao T, Li Y, Liu Y, Zhao X. Nano-hardness, wear resistance and pseudoelasticity of hafnium implanted NiTi shape memory alloy. J Mech Behav Biomed Mater 2012; 13:174-84. [PMID: 22902997 DOI: 10.1016/j.jmbbm.2012.04.004] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2011] [Revised: 03/31/2012] [Accepted: 04/09/2012] [Indexed: 01/25/2023]
Abstract
NiTi shape memory alloy was modified by Hf ion implantation to improve its wear resistance and surface integrity against deformation. The Auger electron spectroscopy and x-ray photoelectron spectroscopy results indicated that the oxide thickness of NiTi alloy was increased by the formation of TiO₂/HfO₂ nanofilm on the surface. The nano-hardness measured by nano-indentation was decreased even at the depth larger than the maximum reach of the implanted Hf ion. The lower coefficient of friction with much longer fretting time indicated the remarkable improvement of wear resistance of Hf implanted NiTi, especially for the sample with a moderate incident dose. The formation of TiO₂/HfO₂ nanofilm with larger thickness and decrease of the nano-hardness played important roles in the improvement of wear resistance. Moreover, Hf implanted NiTi exhibited larger pseudoelastic recovery strain and retained better surface integrity even after being strained to 10% as demonstrated by in situ scanning electron microscope observation.
Collapse
Affiliation(s)
- Tingting Zhao
- School of Materials Science and Engineering, Beihang University, Beijing 100191, China
| | | | | | | |
Collapse
|
15
|
Copper and silver ion implantation of aluminium oxide-blasted titanium surfaces: proliferative response of osteoblasts and antibacterial effects. Int J Artif Organs 2012; 34:882-8. [PMID: 22094570 DOI: 10.5301/ijao.5000022] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/28/2011] [Indexed: 01/26/2023]
Abstract
Implant infection still represents a major clinical problem in orthopedic surgery. We therefore tested the in vitro biocompatibility and antibacterial effects of copper (Cu)- and silver (Ag)-ion implantation. Discs of a commonly used titanium alloy (Ti6AlV4) with an aluminium oxide-blasted surface were treated by Cu- or Ag-ion implantation with different dosage regimen (ranging from 1e15-17 ions cm(-2) at energies of 2-20 keV). The samples were seeded with primary human osteoblasts and cell attachment and proliferation was analyzed by an MTT-assay. In comparison to the reference titanium alloy there was no difference in the number of attached viable cells after two days. After seven days the number of viable cells was increased for Cu with 1e17 ions cm(-2) at 2 and 5 keV, and for Ag with 1e16 ions cm(-2) at 5 keV while it was reduced for the highest amount of Ag deposition (1e17 ions cm(-2) at 20 keV). Antibacterial effects on S.aureus and E.coli were marginal for the studied dosages of Cu but clearly present for Ag with 1e16 ions cm(-2) at 2 and 5 keV and 1e17 ions cm(-2) at 20 keV. These results indicate that Ag-ion implantation may be a promising methodological approach for antibacterial functionalization of titanium implants.
Collapse
|
16
|
Mikulewicz M, Chojnacka K. Cytocompatibility of medical biomaterials containing nickel by osteoblasts: a systematic literature review. Biol Trace Elem Res 2011; 142:865-89. [PMID: 20703824 PMCID: PMC3152710 DOI: 10.1007/s12011-010-8798-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2010] [Accepted: 07/29/2010] [Indexed: 12/12/2022]
Abstract
The present review is based on a survey of 21 studies on the cytocompatibility of medical biomaterials containing nickel, as assessed by cell culture of human and animal osteoblasts or osteoblast-like cells. Among the biomaterials evaluated were stainless steel, NiTi alloys, pure Ni, Ti, and other pure metals. The materials were either commercially available, prepared by the authors, or implanted by various techniques to generate a protective layer of oxides, nitrides, acetylides. The observation that the layers significantly reduced the initial release of metal ions and increased cytocompatibility was confirmed in cell culture experiments. Physical and chemical characterization of the materials was performed. This included, e.g., surface characterization (roughness, wettability, corrosion behavior, quantity of released ions, microhardness, and characterization of passivation layer). Cytocompatibility tests of the materials were conducted in the cultures of human or animal osteoblasts and osteoblast-like cells. The following assays were carried out: cell proliferation and viability test, adhesion test, morphology (by fluorescent microscopy or SEM). Also phenotypic and genotypic markers were investigated. In the majority of works, it was found that the most cytocompatible materials were stainless steel and NiTi alloy. Pure Ni was rendered and less cytocompatible. All the papers confirmed that the consequence of the formation of protective layers was in significant increase of cytocompatibility of the materials. This indicates the possible further modifications of the manufacturing process (formation of the passivation layer).
Collapse
Affiliation(s)
- Marcin Mikulewicz
- Department of Dentofacial Orthopedics and Orthodontics, Medical University of Wrocław, Wrocław, Poland.
| | | |
Collapse
|
17
|
Yang CH, Wang YT, Tsai WF, Ai CF, Lin MC, Huang HH. Effect of oxygen plasma immersion ion implantation treatment on corrosion resistance and cell adhesion of titanium surface. Clin Oral Implants Res 2011; 22:1426-32. [PMID: 21457349 DOI: 10.1111/j.1600-0501.2010.02132.x] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVE The study was to investigate the corrosion resistance and cell adhesion of titanium (Ti) surface for dental implant application by oxygen plasma immersion ion implantation (O-PIII) treatments. MATERIALS AND METHODS Commercially pure Ti discs (grade 2) were used as the substrate. O-PIII surface treatments, with different oxygen doses (1 × 10(16) and 4 × 10(16) ions/cm(2)), were performed in a high-vacuum chamber with a radio frequency plasma source. Atomic force microscope, X-ray photoelectron spectrometer and nanoindenter were used to analyze surface topography, chemical composition (three samples per group) and mechanical property (twenty-five samples per group) of Ti specimens, respectively. Corrosion resistance of Ti specimens (five samples per group) was evaluated by potentiodynamic polarization curve measurement in simulated blood plasma solution. The adhesion and spreading of human bone marrow mesenchymal stem cells (hMSCs) on Ti surfaces were studied. RESULTS The results showed that O-PIII treatment had no significant influence on the surface topography of Ti specimens. The thickness of oxide layer (mainly as TiO(2)) on the O-PIII-treated Ti specimens increased with an increase in oxygen dose implanted. The O-PIII-treated Ti specimens possessed higher surface hardness and Young's modulus than the untreated Ti specimen. Potentiodynamic polarization tests revealed that the O-PIII-treated Ti surfaces had lower corrosion rate (I(corr)) and passive current (I(pass)) than the untreated Ti surface. The adhesion and spreading of hMSCs on Ti surfaces were improved by O-PIII treatment. CONCLUSIONS O-PIII treatment could enhance the corrosion resistance and cell adhesion of Ti surface for dental implant application due to the increase in surface thickness of Ti-oxides (mainly as TiO(2)) on Ti.
Collapse
Affiliation(s)
- Chih-Hsiung Yang
- Institute of Oral Biology, National Yang-Ming University, Taipei, Taiwan
| | | | | | | | | | | |
Collapse
|
18
|
Muguruma T, Iijima M, Brantley WA, Mizoguchi I. Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires. Angle Orthod 2011; 81:141-48. [PMID: 20936967 DOI: 10.2319/052110-276.1] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE To test the hypothesis that a diamond-like carbon coating does not affect the frictional properties of orthodontic wires. MATERIALS AND METHODS Two types of wires (nickel-titanium and stainless steel) were used, and diamond-like carbon (DLC) films were deposited on the wires. Three types of brackets, a conventional stainless steel bracket and two self-ligating brackets, were used for measuring static friction. DLC layers were observed by three-dimensional scanning electron microscopy (3D-SEM), and the surface roughness was measured. Hardness and elastic modulus were obtained by nanoindentation testing. Frictional forces and surface roughness were compared by the Kruskal-Wallis and Mann-Whitney U-tests. The hardness and elastic modulus of the wires were compared using Student's t-test. RESULTS When angulation was increased, the DLC-coated wires showed significantly less frictional force than the as-received wires, except for some wire/bracket combinations. Thin DLC layers were observed on the wire surfaces by SEM. As-received and DLC-coated wires had similar surface morphologies, and the DLC-coating process did not affect the surface roughness. The hardness of the surface layer of the DLC-coated wires was much higher than for the as-received wires. The elastic modulus of the surface layer of the DLC-coated stainless steel wire was less than that of the as-received stainless steel wire, whereas similar values were found for the nickel-titanium wires. CONCLUSIONS The hypothesis is rejected. A DLC-coating process does reduce the frictional force.
Collapse
Affiliation(s)
- Takeshi Muguruma
- Department of Oral Growth and Development, University of Hokkaido, Japan
| | | | | | | |
Collapse
|
19
|
Tian H, Schryvers D, Liu D, Jiang Q, Van Humbeeck J. Stability of Ni in nitinol oxide surfaces. Acta Biomater 2011; 7:892-9. [PMID: 20849983 DOI: 10.1016/j.actbio.2010.09.009] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2010] [Revised: 09/04/2010] [Accepted: 09/08/2010] [Indexed: 11/18/2022]
Abstract
The stability of Ni in titanium oxide surface layers on nitinol wires known to release certain amounts of Ni was investigated by first principles density functional theory and transmission electron microscopy. The oxides were identified as a combination of TiO and TiO(2) depending on the thickness of the layer. The calculations indicate that free Ni atoms can exist in TiO at ambient temperature while Ni particles form in TiO(2), which was confirmed by the transmission electron microscopy observations. The results are discussed with respect to surface stability and Ni release due to free Ni atoms and Ni particles.
Collapse
Affiliation(s)
- He Tian
- EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
| | | | | | | | | |
Collapse
|
20
|
Effect of Ta2O5/TiO2 thin film on mechanical properties, corrosion and cell behavior of the NiTi alloy implanted with tantalum. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2010. [DOI: 10.1016/j.msec.2010.07.001] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
21
|
IIJIMA M, YUASA T, ENDO K, MUGURUMA T, OHNO H, MIZOGUCHI I. Corrosion behavior of ion implanted nickel-titanium orthodontic wire in fluoride mouth rinse solutions. Dent Mater J 2010; 29:53-8. [DOI: 10.4012/dmj.2009-069] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
22
|
Shabalovskaya S, Anderegg J, Van Humbeeck J. Critical overview of Nitinol surfaces and their modifications for medical applications. Acta Biomater 2008; 4:447-67. [PMID: 18328796 DOI: 10.1016/j.actbio.2008.01.013] [Citation(s) in RCA: 174] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2007] [Revised: 11/16/2007] [Accepted: 01/10/2008] [Indexed: 10/22/2022]
Abstract
Nitinol, a group of nearly equiatomic shape memory and superelastic NiTi alloys, is being extensively explored for medical applications. Release of Ni in the human body, a potential problem with Nitinol implant devices, has stimulated a great deal of research on its surface modifications and coatings. In order to use any of the developed surfaces in implant designs, it is important to understand whether they really have advantages over bare Nitinol. This paper overviews the current situation, discusses the advantages and disadvantages of new surfaces as well as the limitations of the studies performed. It presents a comprehensive analysis of surface topography, chemistry, corrosion behavior, nickel release and biological responses to Nitinol surfaces modified mechanically or using such methods as etching in acids and alkaline solutions, electropolishing, heat and ion beam treatments, boiling in water and autoclaving, conventional and ion plasma implantations, laser melting and bioactive coating deposition. The analysis demonstrates that the presently developed surfaces vary in thickness from a few nanometers to micrometers, and that they can effectively prevent Ni release if the surface integrity is maintained under strain and if no Ni-enriched sub-layers are present. Whether it is appropriate to use various low temperature pre-treatment protocols (< or = 160 degrees C) developed originally for pure titanium for Nitinol surface modifications and coatings is also discussed. The importance of selection of original Nitinol surfaces with regard to the performance of coatings and comparative performance of controls in the studies is emphasized. Considering the obvious advantages of bare Nitinol surfaces for superelastic implants, details of their preparation are also outlined.
Collapse
|
23
|
Liu XM, Wu SL, Chan YL, Chu PK, Chung CY, Chu CL, Yeung KWK, Lu WW, Cheung KMC, Luk KDK. Surface characteristics, biocompatibility, and mechanical properties of nickel-titanium plasma-implanted with nitrogen at different implantation voltages. J Biomed Mater Res A 2007; 82:469-78. [PMID: 17295249 DOI: 10.1002/jbm.a.31157] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
NiTi shape memory alloy is one of the promising orthopedic materials due to the unique shape memory effect and superelasticity. However, the large amount of Ni in the alloy may cause allergic reactions and toxic effects thereby limiting its applications. In this work, the surface of NiTi alloy was modified by nitrogen plasma immersion ion implantation (N-PIII) at various voltages. The materials were characterized by X-ray photoelectron spectroscopy (XPS). The topography and roughness before and after N-PIII were measured by atomic force microscope. The effects of the modified surfaces on nickel release and cytotoxicity were assessed by immersion tests and cell cultures. The XPS results reveal that near-surface Ni concentration is significantly reduced by PIII and the surface TiN layer suppresses nickel release and favors osteoblast proliferation, especially for samples implanted at higher voltages. The surfaces produced at higher voltages of 30 and 40 kV show better adhesion ability to osteoblasts compared to the unimplanted and 20 kV PIII samples. The effects of heating during PIII on the phase transformation behavior and cyclic deformation response of the materials were investigated by differential scanning calorimetry and three-point bending tests. Our results show that N-PIII conducted using the proper conditions improves the biocompatibility and mechanical properties of the NiTi alloy significantly.
Collapse
Affiliation(s)
- X M Liu
- Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Li UM, Iijima M, Endo K, Brantley WA, Alapati SB, Lin CP. Application of Plasma Immersion Ion Implantation for Surface Modification of Nickel-titanium Rotary Instruments. Dent Mater J 2007; 26:467-73. [PMID: 17886448 DOI: 10.4012/dmj.26.467] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
By means of X-ray photoelectron spectroscopy (XPS) and differential scanning calorimetry (DSC), this study set out to investigate the application of plasma immersion ion implantation (PIII) for the surface modification of ProTaper NiTi rotary instruments. This study was undertaken because the PIII method was perceived to have the potential of developing into a standard surface modification technique that improves clinical quality and outcome. Specimens received nitrogen ion or nitrogen plus argon ion implantation. XPS analyses with and without argon ion etching were obtained for all specimens. In addition, DSC analysis was performed to investigate the phase transformation behavior of the bulk material. Results indicated that the surfaces of NiTi instruments were successfully modified by nitrogen PIII, whereby a light golden TiN layer was yielded. Moreover, the PIII technique did not alter the superelastic character of NiTi instruments because it was carried out at near-room temperature. We thus concluded that nitrogen PIII is a promising surface modification technique to improve the surface characteristics of NiTi rotary instruments.
Collapse
Affiliation(s)
- Uei-Ming Li
- School of Dentistry and Graduate Institute of Clinical Dentistry, College of Medicine, National Taiwan University and National Taiwan University Hospital, Taipei 10016, Taiwan, ROC
| | | | | | | | | | | |
Collapse
|
25
|
Yeung KWK, Lu WW, Luk KDK, Cheung KMC. Mechanical testing of a smart spinal implant locking mechanism based on nickel-titanium alloy. Spine (Phila Pa 1976) 2006; 31:2296-303. [PMID: 16985456 DOI: 10.1097/01.brs.0000238967.82799.3d] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Development and testing of a new spinal implant-locking mechanism based on the special properties of nickel-titanium alloy. OBJECTIVE To develop a new self-tightening locking mechanism to reduce fretting corrosion at implant junctions. SUMMARY OF BACKGROUND DATA All current implant locking involves tightening of a nut against the rod and screw head to form a coupling. Particulate debris is generated, and the coupling becomes loose because of wear between the rod and locking mechanism (fretting). To avoid this fretting, a new locking mechanism with an automatic retightening effect based on the superelastic and shape-memory properties of nickel-titanium alloy has been developed. METHOD The new coupling made of nickel-titanium alloy will tightly lock the rod when temperature increases to 50 degrees C (shape-memory effect). If fretting occurs, the coupling will further tighten itself around the rod (superelastic effect). This new coupling is mechanically tested against 4 current implant couplings. RESULTS In axial compression, conventional couplings failed between 570 and 740 N, while the new coupling reached 800 N without loosening. In axial rotation, conventional devices failed between 1.8 and 5.3 Nm, while the new coupling reached 6.5 Nm without failure. During testing, the retightening effect could be seen on the force versus displacement plot. CONCLUSIONS To our knowledge, the self-tightening coupling is a new concept not previously described and is attributable to the superior superelastic effect of the new coupling. This implant coupling has the potential to be used as a very low profile system and also in nonfusion technologies in which demands on the coupling would not higher without the protection of spinal fusion.
Collapse
Affiliation(s)
- Kelvin W K Yeung
- Division of Spine Surgery, Department of Orthopaedics and Traumatology, Queen Mary Hospital, The University of Hong Kong, Pokfulam, Hong Kong
| | | | | | | |
Collapse
|