1
|
Zhang YJ, Xue T, Liu C, Hao YH, Yan XH, Liu LP. Radiomics Combined with ACR TI-RADS for Thyroid Nodules: Diagnostic Performance, Unnecessary Biopsy Rate, and Nomogram Construction. Acad Radiol 2024; 31:4856-4865. [PMID: 39366806 DOI: 10.1016/j.acra.2024.07.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Revised: 07/27/2024] [Accepted: 07/30/2024] [Indexed: 10/06/2024]
Abstract
RATIONALE AND OBJECTIVES To develop a radiomics model with enhanced diagnostic performance, reduced unnecessary fine needle aspiration biopsy (FNA) rate, and improved clinical net benefit for thyroid nodules. METHODS We conducted a retrospective study of 217 thyroid nodules. Lesions were divided into training (n = 152) and verification (n = 65) cohorts. Three radiomics scores were derived from B-mode ultrasound (B-US) and strain elastography (SE) images, alone and in combination. A radiomics nomogram was constructed by combining high-frequency ultrasonic features and the best-performing radiomics score. The area under the receiver operating characteristic curve (AUC), unnecessary FNA rate, and decision curve analysis (DCA) results for the nomogram were compared to those obtained with the American College of Radiology Thyroid Imaging, Reporting and Data System (ACR TI-RADS) score and the combined TI-RADS+SE+ contrast-enhanced ultrasound (CEUS) advanced clinical score. RESULTS The three radiomics scores (B-US, SE, B-US+SE) achieved training AUCs of 0.753 (0.668-0.825), 0.761 (0.674-0.838), and 0.795 (0.715-0.871), and validation AUCs of 0.732 (0.579-0.867), 0.753 (0.609-0.892), and 0.752 (0.592-0.899) respectively. The AUC of the nomogram for the entire patient cohort was 0.909 (0.864-0.954), which was higher than that of the ACR TI-RADS score (P < 0.001) and equivalent to the TI-RADS+SE+CEUS score (P = 0.753). Similarly, the unnecessary FNA rate of the radiomics nomogram was significantly lower than that of the ACR TI-RADS score (P = 0.007) and equivalent to the TI-RADS+SE+CEUS score (P = 0.457). DCA also showed that the radiomics nomogram brought more net clinical benefit than the ACR TI-RADS score but was similar to that of the TI-RADS+SE+CEUS score. CONCLUSION The radiomics nomogram developed in this study can be used as an objective, accurate, cost-effective, and noninvasive method for the characterization of thyroid nodules.
Collapse
Affiliation(s)
- Yan-Jing Zhang
- Department of Interventional Ultrasound, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, 030001, PR China
| | - Tian Xue
- Department of Interventional Ultrasound, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, 030001, PR China
| | - Chang Liu
- Department of Interventional Ultrasound, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, 030001, PR China
| | - Yan-Hong Hao
- Department of Interventional Ultrasound, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, 030001, PR China
| | - Xiao-Hui Yan
- Department of Interventional Ultrasound, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, 030001, PR China
| | - Li-Ping Liu
- Department of Interventional Ultrasound, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, 030001, PR China.
| |
Collapse
|
2
|
Brandenstein MK, Zhang L, Scharf G, Thurn S, Hornung M, Menhart K, Meiler S, Stroszczynski C, Jung EM. The impact of V-flow on preoperative diagnosis of thyroid tumors: individually and as part of multimodal sonographic imaging. ROFO-FORTSCHR RONTG 2024. [PMID: 39038458 DOI: 10.1055/a-2350-0107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/24/2024]
Abstract
V-flow is a dynamic ultrasound technique that visualizes perfusion patterns by displaying dynamic arrows that change in response to the flow of erythrocytes. Furthermore, it provides quantitative values for the maximum and mean velocity of blood flow as well as a percentage value for turbulence. The aim was to enhance the preoperative diagnostic accuracy of thyroid lesions by combining V-flow with established ultrasound modes.B-mode, CCDS, elastography, CEUS, and V-flow were performed on 101 patients. After the ultrasound examination, every nodule was confirmed as benign or malignant via histopathology. The Kruskal-Wallis test, ROC curve, and binary logistic regression were used for the statistical analysis.93 benign regressive thyroid nodules and 8 carcinomas were included in this study. The average mean velocity value for benign lesions was measured at 19.5 cm/s and at 10.7 cm/s for malignant lesions (p = 0.039). The average turbulence percentage was 26.1% for benign nodules and 46.7% for carcinomas (p = 0.016). Carcinomas exhibited a slower and more turbulent perfusion pattern compared to benign tumors. A V-flow-centered system achieves a sensitivity of 100.0% and a specificity of 84.9% in predicting malignancy. This system could have reduced the number of unnecessary thyroid surgeries for benign lesions in our patient group by 70%.The capillary perfusion of thyroid nodules represents a significant indicator of its status. By analyzing the velocity and turbulence level of microvascular blood flow, V-flow offers promising prospects for accurately distinguishing between benign and malignant thyroid lesions. When integrated into a comprehensive multimodal sonographic imaging approach, V-flow further enhances diagnostic accuracy. · V-flow allows for qualitative and quantitative analysis of microvascular perfusion. · Malignant tumors are associated with slower and more turbulent microvascular hemodynamics. · Combining V-flow with other ultrasound modes eases the diagnosis of thyroid carcinomas. · Brandenstein MK, Zhang L, Scharf G et al. The impact of V-flow on preoperative diagnosis of thyroid tumors: individually and as part of multimodal sonographic imaging. Fortschr Röntgenstr 2024; DOI 10.1055/a-2350-0107.
Collapse
Affiliation(s)
| | - Liang Zhang
- Radiology, University Hospital Regensburg, Regensburg, Germany
| | - Gregor Scharf
- Radiology, University Hospital Regensburg, Regensburg, Germany
| | - Sylvia Thurn
- Radiology, University Hospital Regensburg, Regensburg, Germany
| | | | - Karin Menhart
- Nuclear Medicine, University Hospital Regensburg, Regensburg, Germany
| | - Stefanie Meiler
- Radiology, University Hospital Regensburg, Regensburg, Germany
| | | | | |
Collapse
|
3
|
Borlea A, Moisa-Luca L, Popescu A, Bende F, Stoian D. Combining CEUS and ultrasound parameters in thyroid nodule and cancer diagnosis: a TIRADS-based evaluation. Front Endocrinol (Lausanne) 2024; 15:1417449. [PMID: 38952390 PMCID: PMC11215041 DOI: 10.3389/fendo.2024.1417449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2024] [Accepted: 05/20/2024] [Indexed: 07/03/2024] Open
Abstract
Contrast-enhanced ultrasonography (CEUS) has been established as a diagnostic tool for assessing microvascularization, essential for understanding angiogenesis in neoplastic development. AIM This study assesses the effectiveness of CEUS as a supplementary tool to TIRADS in enhancing the ultrasound-based diagnosis of thyroid cancer. METHODS AND MATERIALS Over one year, 157 nodules in 133 patients, with predominantly solid thyroid nodules, were examined using ultrasound and CEUS and underwent thyroidectomy, allowing for a comparison of ultrasound findings with pathological reports. RESULTS Thyroid cancer was identified in 31.21% (49/157) of cases. Significant CEUS high-risk features included inhomogeneous enhancement, enhancement defects, and complete hypoenhancement (AUC 0.818, 0.767, 0.864 respectively). Nodules exhibiting any of these features were classified as high-risk in CEUS. The diagnostic performance of TIRADS improved when combined with CEUS, with AUC increasing from 0.707 to 0.840 and improved sensitivity. CONCLUSION The integration of CEUS with TIRADS significantly enhances the diagnostic accuracy and specificity in identifying thyroid cancer. This combination proves to be a more effective method for risk stratification and diagnosis, highlighting the value of CEUS as an adjunctive tool in thyroid cancer evaluation.
Collapse
Affiliation(s)
- Andreea Borlea
- Division of Endocrinology, Department of Internal Medicine II, “Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania
- Centre for Molecular Research in Nephrology and Vascular Disease, “Victor Babeş” University of Medicine and Pharmacy, Timişoara, Romania
| | - Luciana Moisa-Luca
- Division of Endocrinology, Department of Internal Medicine II, “Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania
- Centre for Molecular Research in Nephrology and Vascular Disease, “Victor Babeş” University of Medicine and Pharmacy, Timişoara, Romania
| | - Alina Popescu
- Division of Gastroenterology and Hepatology, Department of Internal Medicine II, “Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania
| | - Felix Bende
- Division of Gastroenterology and Hepatology, Department of Internal Medicine II, “Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania
| | - Dana Stoian
- Division of Endocrinology, Department of Internal Medicine II, “Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania
- Centre for Molecular Research in Nephrology and Vascular Disease, “Victor Babeş” University of Medicine and Pharmacy, Timişoara, Romania
| |
Collapse
|
4
|
Żyłka A, Dobruch-Sobczak K, Piotrzkowska-Wróblewska H, Jędrzejczyk M, Bakuła-Zalewska E, Góralski P, Gałczyński J, Dedecjus M. The Utility of Contrast-Enhanced Ultrasound (CEUS) in Assessing the Risk of Malignancy in Thyroid Nodules. Cancers (Basel) 2024; 16:1911. [PMID: 38791990 PMCID: PMC11119249 DOI: 10.3390/cancers16101911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 05/01/2024] [Accepted: 05/11/2024] [Indexed: 05/26/2024] Open
Abstract
BACKGROUND Ultrasonography is a primary method used in the evaluation of thyroid nodules, but no single feature of this method predicts malignancy with high accuracy. Therefore, this paper aims to assess the utility of contrast-enhanced ultrasound (CEUS) in the differential diagnosis of thyroid nodules. METHODS The study group comprised 188 adult patients (155 women and 33 men) who preoperatively underwent CEUS of a thyroid nodule classified as Bethesda categories II-VI after fine-needle aspiration biopsy. During the CEUS examination, 1.5 mL of SonoVue contrast was injected intravenously, after which 15 qualitative CEUS enhancement patterns were analysed. RESULTS The histopathologic results comprised 65 benign thyroid nodules and 123 thyroid carcinomas. The dominant malignant CEUS features, such as hypo- and heterogeneous enhancement and slow wash-in phase, were evaluated, whereas high enhancement, ring enhancement, and a slow wash-out phase were assessed as predictors of benign lesions. Two significant combinations of B-mode and CEUS patterns were noted, namely, hypoechogenicity with heterogeneous enhancement and non-smooth margins with hypo- or iso-enhancement. CONCLUSIONS The preliminary results indicate that CEUS is a useful tool in assessing the risk of malignancy of thyroid lesions. The combination of the qualitative enhancement parameters and B-mode sonographic features significantly increases the method's usefulness.
Collapse
Affiliation(s)
- Agnieszka Żyłka
- Department of Endocrine Oncology and Nuclear Medicine, Maria Sklodowska-Curie National Research Institute of Oncology, 02-781 Warsaw, Poland; (P.G.); (J.G.); (M.D.)
| | - Katarzyna Dobruch-Sobczak
- Radiology Department II, Maria Sklodowska-Curie National Research Institute of Oncology, 02-034 Warsaw, Poland;
| | - Hanna Piotrzkowska-Wróblewska
- Department of Ultrasound, Institute of Fundamental Technological Research, Polish Academy of Sciences, 02-106 Warsaw, Poland;
| | - Maciej Jędrzejczyk
- Department of Ultrasound and Mammography Diagnostics, Mazovian Brodnowski Hospital, 03-242 Warsaw, Poland;
| | - Elwira Bakuła-Zalewska
- Department of Pathology, Maria Sklodowska-Curie National Research Institute of Oncology, 02-781 Warsaw, Poland;
| | - Piotr Góralski
- Department of Endocrine Oncology and Nuclear Medicine, Maria Sklodowska-Curie National Research Institute of Oncology, 02-781 Warsaw, Poland; (P.G.); (J.G.); (M.D.)
| | - Jacek Gałczyński
- Department of Endocrine Oncology and Nuclear Medicine, Maria Sklodowska-Curie National Research Institute of Oncology, 02-781 Warsaw, Poland; (P.G.); (J.G.); (M.D.)
| | - Marek Dedecjus
- Department of Endocrine Oncology and Nuclear Medicine, Maria Sklodowska-Curie National Research Institute of Oncology, 02-781 Warsaw, Poland; (P.G.); (J.G.); (M.D.)
| |
Collapse
|
5
|
Wang B, Ou X, Yang J, Zhang H, Cui XW, Dietrich CF, Yi AJ. Contrast-enhanced ultrasound and shear wave elastography in the diagnosis of ACR TI-RADS 4 and 5 category thyroid nodules coexisting with Hashimoto's thyroiditis. Front Oncol 2023; 12:1022305. [PMID: 36713579 PMCID: PMC9874292 DOI: 10.3389/fonc.2022.1022305] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 12/19/2022] [Indexed: 01/13/2023] Open
Abstract
Objective This study aims to evaluate the value of contrast-enhanced ultrasound (CEUS), shear wave elastography (SWE), and their combined use in the differentiation of American College of Radiology (ACR) thyroid imaging reporting and data system (TI-RADS) 4 and 5 category thyroid nodules coexisting with Hashimoto's thyroiditis (HT). Materials and methods A total of 133 pathologically confirmed ACR TI-RADS 4 and 5 category nodules coexisting with HT in 113 patients were included; CEUS and SWE were performed for all nodules. The sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), accuracy, and the area under the receiver operating characteristic curve (AUC) of the SWE, CEUS, and the combined use of both for the differentiation of benign and malignant nodules were compared, respectively. Results Using CEUS alone, the sensitivity, specificity, PPV, NPV, and accuracy were 89.2%, 66.0%, 81.3%, 78.6%, and 80.5%, respectively. Using SWE alone, Emax was superior to Emin, Emean, and Eratio for the differentiation of benign and malignant nodules with the best cutoff Emax >46.8 kPa, which had sensitivity of 65.1%, specificity of 90.0%, PPV of 91.5%, NPV of 60.8%, and accuracy of 74.4%, respectively. Compared with the diagnostic performance of qualitative CEUS or/and quantitative SWE, the combination of CEUS and SWE had the best sensitivity, accuracy, and AUC; the sensitivity, specificity, PPV, NPV, accuracy, and AUC were 94.0%, 66.0%, 82.1%, 86.8%, 83.5%, and 0.80 (95% confidence interval: 0.713, 0.886), respectively. Conclusion In conclusion, CEUS and SWE were useful for the differentiation of benign and malignant ACR TI-RADS 4 and 5 category thyroid nodules coexisting with HT. The combination of CEUS and SWE could improve the sensitivity and accuracy compared with using CEUS or SWE alone. It could be a non-invasive, reliable, and useful method to differentiate benign from malignant ACR TI-RADS 4 and 5 category thyroid nodules coexisting with HT.
Collapse
Affiliation(s)
- Bin Wang
- Department of Medical Ultrasound, Yueyang Central Hospital, Yueyang, China
| | - Xiaoyan Ou
- Department of Medical Ultrasound, Yueyang Central Hospital, Yueyang, China
| | - Juan Yang
- Department of Medical Ultrasound, Yueyang Central Hospital, Yueyang, China
| | - Haibo Zhang
- Department of Medical Ultrasound, Yueyang Central Hospital, Yueyang, China
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China,*Correspondence: Xin-Wu Cui, ; Ai-Jiao Yi,
| | - Christoph F. Dietrich
- Department Allgemeine Innere Medizin, Kliniken Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland
| | - Ai-Jiao Yi
- Department of Medical Ultrasound, Yueyang Central Hospital, Yueyang, China,*Correspondence: Xin-Wu Cui, ; Ai-Jiao Yi,
| |
Collapse
|
6
|
Brandenstein M, Wiesinger I, Künzel J, Hornung M, Stroszczynski C, Jung EM. Multiparametric Sonographic Imaging of Thyroid Lesions: Chances of B-Mode, Elastography and CEUS in Relation to Preoperative Histopathology. Cancers (Basel) 2022; 14:cancers14194745. [PMID: 36230668 PMCID: PMC9564296 DOI: 10.3390/cancers14194745] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 09/21/2022] [Accepted: 09/23/2022] [Indexed: 12/03/2022] Open
Abstract
Simple Summary As the incidence of thyroid lesions in Europe is rising, more and more people affected by thyroid pathologies seek treatment in a clinic. Every suspicious thyroid nodule needs to be confirmed as benign or malignant in order to be treated correctly. Unnecessary invasive diagnostics and thyroid surgery should be avoided. The aim of this retrospective study was to improve the distinction between benign and malignant nodules by using new high-performance multiparametric ultrasound examination techniques. By analyzing 122 thyroid nodules we created a score-based system combining B-mode, shear-wave elastography and contrast-enhanced ultrasound malignancy criteria. This system allows for a quite accurate detection of thyroid carcinomas with a sensitivity of 95% and specificity of 75.49%. Shear-wave elastography and contrast-enhanced ultrasound can detect unique malignancy features, which cannot be found in B-mode. Therefore, these criteria would present a relevant addition to the B-mode TI-RADS classification. Abstract Background: The aim was to improve preoperative diagnostics of solid non-cystic thyroid lesions by using new high-performance multiparametric ultrasound examination techniques. Methods: Multiparametric ultrasound consists of B-mode, shear-wave elastography and contrast enhanced ultrasound (CEUS) including Time-Intensity-Curve (TIC) analysis. A bolus of 1–2.4 mL Sulfur Hexafluorid microbubbles was injected for CEUS. Postoperative histopathology was the diagnostic gold standard. Results: 116 patients were included in this study. 102 benign thyroid nodules were diagnosed as well as 20 carcinomas. Suspicious B-mode findings like microcalcifications, a blurry edge and no homogeneous sonomorphological structure were detected in 60, 75 and 80% of all carcinomas but only in 13.7, 36.3 and 46.1% of all benign lesions. The average shear-wave elastography measurements of malignant lesions (4.6 m/s or 69.8 kPa centrally and 4.2 m/s or 60.1 kPa marginally) exceed the values of benign nodules. Suspicious CEUS findings like a not-homogeneous wash-in and a wash-out were detected almost twice as often in carcinomas. Conclusion: Multiparametric ultrasound offers new possibilities for the preoperative distinction between benign and malignant thyroid nodules. A score based system of B-mode, shear-wave and CEUS malignancy criteria shows promising results in the detection of thyroid carcinomas. It reaches a sensitivity of 95% and specificity of 75.49%.
Collapse
Affiliation(s)
- Moritz Brandenstein
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital, 93053 Regensburg, Germany
- Correspondence: ; Tel.: +49-17-647-793-303
| | - Isabel Wiesinger
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital, 93053 Regensburg, Germany
| | - Julian Künzel
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital of Regensburg, 93053 Regensburg, Germany
| | - Matthias Hornung
- Department of Surgery, University Hospital, 93053 Regensburg, Germany
| | - Christian Stroszczynski
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital, 93053 Regensburg, Germany
| | - Ernst-Michael Jung
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital, 93053 Regensburg, Germany
| |
Collapse
|
7
|
Yi D, Fan L, Zhu J, Yao J, Peng C, Xu D. The diagnostic value of a nomogram based on multimodal ultrasonography for thyroid-nodule differentiation: A multicenter study. Front Oncol 2022; 12:970758. [PMID: 36059607 PMCID: PMC9435436 DOI: 10.3389/fonc.2022.970758] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 08/01/2022] [Indexed: 11/17/2022] Open
Abstract
Objective To establish and verify a nomogram based on multimodal ultrasonography (US) for the assessment of the malignancy risk of thyroid nodules and to explore its value in distinguishing benign from malignant thyroid nodules. Methods From September 2020 to December 2021, the data of 447 individuals with thyroid nodules were retrieved from the multicenter database of medical images of the National Health Commission’s Capacity Building and Continuing Education Center, which includes data from more than 20 hospitals. All patients underwent contrast-enhanced US (CEUS) and elastography before surgery or fine needle aspiration. The training set consisted of three hundred datasets from the multicenter database (excluding Zhejiang Cancer Hospital), and the external validation set consisted of 147 datasets from Zhejiang Cancer Hospital. As per the pathological results, the training set was separated into benign and malignant groups. The characteristics of the lesions in the two groups were analyzed and compared using conventional US, CEUS, and elastography score. Using multivariate logistic regression to screen independent predictive risk indicators, then a nomogram for risk assessment of malignant thyroid nodules was created. The diagnostic performance of the nomogram was assessed utilizing calibration curves and receiver operating characteristic (ROC) from the training and validation cohorts. The nomogram and The American College of Radiology Thyroid Imaging, Reporting and Data System were assessed clinically using decision curve analysis (DCA). Results Multivariate regression showed that irregular shape, elastography score (≥ 3), lack of ring enhancement, and unclear margin after enhancement were independent predictors of malignancy. During the training (area under the ROC [AUC]: 0.936; 95% confidence interval [CI]: 0.902–0.961) and validation (AUC: 0.902; 95% CI: 0.842–0.945) sets, the multimodal US nomogram with these four variables demonstrated good calibration and discrimination. The DCA results confirmed the good clinical applicability of the multimodal US nomogram for predicting thyroid cancer. Conclusions As a preoperative prediction tool, our multimodal US-based nomogram showed good ability to distinguish benign from malignant thyroid nodules.
Collapse
Affiliation(s)
- Dan Yi
- 1Department of Ultrasound, Shaoxing People’s Hospital, Shaoxing, China
- Zhejiang Chinese Medical University, Hangzhou, China
| | - Libin Fan
- Department of Surgery, Affiliated Hospital of Shaoxing University, Shaoxing, China
| | - Jianbo Zhu
- 1Department of Ultrasound, Shaoxing People’s Hospital, Shaoxing, China
| | - Jincao Yao
- Department of Ultrasound in Medicine, Cancer Hospital of the University of Chinese Academy of Sciences (Zhejiang Cancer Hospital), Hangzhou, China
| | - Chanjuan Peng
- Department of Ultrasound in Medicine, Cancer Hospital of the University of Chinese Academy of Sciences (Zhejiang Cancer Hospital), Hangzhou, China
- *Correspondence: Dong Xu, ; Chanjuan Peng,
| | - Dong Xu
- Department of Ultrasound in Medicine, Cancer Hospital of the University of Chinese Academy of Sciences (Zhejiang Cancer Hospital), Hangzhou, China
- Key Laboratory of Head & Neck Cancer Translational Research of Zhejiang Province, Hangzhou, China
- Zhejiang Provincial Research Center for Cancer Intelligent Diagnosis and Molecular Technology, Hangzhou, China
- *Correspondence: Dong Xu, ; Chanjuan Peng,
| |
Collapse
|
8
|
Contrast-Enhanced Ultrasonography for Differential Diagnosis of Benign and Malignant Thyroid Lesions: Single-Institutional Prospective Study of Qualitative and Quantitative CEUS Characteristics. CONTRAST MEDIA & MOLECULAR IMAGING 2022; 2022:8229445. [PMID: 35542754 PMCID: PMC9056255 DOI: 10.1155/2022/8229445] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 03/02/2022] [Accepted: 03/17/2022] [Indexed: 11/17/2022]
Abstract
Objectives To extend and revise the diagnostic value of contrast-enhanced ultrasonography (CEUS) for differentiation between malignant and benign thyroid nodules. Methods This single-institution prospective study aims to compare CEUS qualitative and objective quantitative parameters in benign and malignant thyroid nodules. Consecutive cohort of 100 patients was examined by CEUS, 68 out of them were further analysed in detail. All included patients underwent cytological and/or histopathological verification of the diagnosis. Results Fifty-five (81%) thyroid nodules were benign, and 13 (19%) were malignant. Ring enhancement pattern was strongly associated with a benign aetiology (positive predictive value 100%) and heterogeneous enhancement pattern with malignant aetiology (positive predictive value 72.7%). The shape of the TIC (time-intensity curve) was more often identical in the benign lesion (98.2%) than in malignant lesions (69.2%), p=0.004. Conclusions This study indicates that CEUS enhancement patterns were significantly different in benign and malignant lesions. Ring enhancement was a very strong indicator of benign lesions, whereas heterogeneous enhancement was valuable to detect malignant lesions.
Collapse
|
9
|
Advanced Ultrasound Techniques for Differentiation of Benign Versus Malignant Thyroid Nodules: A Review. Ultrasound Q 2021; 37:315-323. [PMID: 34855707 DOI: 10.1097/ruq.0000000000000543] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
ABSTRACT Grayscale ultrasound (US) is decisive in stratifying which thyroid nodules benefit from fine-needle aspiration to evaluate for malignancy. Unfortunately, a significant percentage of nodules remain indeterminate.Herein, we review the clinical considerations and diagnostic accuracy of advanced US, Doppler US, contrast-enhanced US, and US elastography techniques in the evaluation of indeterminate nodules.We conclude that these techniques may be used in combination with grayscale US to improve the assessment of lesion vascularity and tissue property.
Collapse
|
10
|
Radzina M, Ratniece M, Putrins DS, Saule L, Cantisani V. Performance of Contrast-Enhanced Ultrasound in Thyroid Nodules: Review of Current State and Future Perspectives. Cancers (Basel) 2021; 13:5469. [PMID: 34771632 PMCID: PMC8582579 DOI: 10.3390/cancers13215469] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 10/20/2021] [Accepted: 10/27/2021] [Indexed: 12/12/2022] Open
Abstract
Ultrasound has been established as a baseline imaging technique for thyroid nodules. The main advantage of adding CEUS is the ability to assess the sequence and intensity of vascular perfusion and hemodynamics in the thyroid nodule, thus providing real-time characterization of nodule features, considered a valuable new approach in the determination of benign vs. malignant nodules. Original studies, reviews and six meta-analyses were included in this article. A total of 624 studies were retrieved, and 107 were included in the study. As recognized for thyroid nodule malignancy risk stratification by US, for acceptable accuracy in malignancy a combination of several CEUS parameters should be applied: hypo-enhancement, heterogeneous, peripheral irregular enhancement in combination with internal enhancement patterns, and slow wash-in and wash-out curve lower than in normal thyroid tissue. In contrast, homogeneous, intense enhancement with smooth rim enhancement and "fast-in and slow-out" are indicative of the benignity of the thyroid nodule. Even though overlapping features require standardization, with further research, CEUS may achieve reliable performance in detecting or excluding thyroid cancer. It can also play an operative role in guiding ablation procedures of benign and malignant thyroid nodules and metastatic lymph nodes, and providing accurate follow-up imaging to assess treatment efficacy.
Collapse
Affiliation(s)
- Maija Radzina
- Radiology Research Laboratory, Riga Stradins University, LV-1007 Riga, Latvia; (M.R.); (L.S.)
- Medical Faculty, University of Latvia, LV-1004 Riga, Latvia;
- Diagnostic Radiology Institute, Paula Stradina Clinical University Hospital, LV-1002 Riga, Latvia
| | - Madara Ratniece
- Radiology Research Laboratory, Riga Stradins University, LV-1007 Riga, Latvia; (M.R.); (L.S.)
| | - Davis Simanis Putrins
- Medical Faculty, University of Latvia, LV-1004 Riga, Latvia;
- Diagnostic Radiology Institute, Paula Stradina Clinical University Hospital, LV-1002 Riga, Latvia
| | - Laura Saule
- Radiology Research Laboratory, Riga Stradins University, LV-1007 Riga, Latvia; (M.R.); (L.S.)
- Diagnostic Radiology Institute, Paula Stradina Clinical University Hospital, LV-1002 Riga, Latvia
| | - Vito Cantisani
- Department of Radiological, Anatomopathological and Oncological Sciences, Sapienza University of Rome, 00100 Rome, Italy;
| |
Collapse
|
11
|
Xu J, Wang P, Yue W, Luo Y, Li Z. Application of ultrasonic shear wave elastography and contrast-enhanced ultrasound in the differential diagnosis of patients with benign and malignant thyroid lesions. Gland Surg 2020; 9:2136-2143. [PMID: 33447564 DOI: 10.21037/gs-20-819] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Background Thyroid nodules are a common thyroid disorder. The aim of the present study was to observe the application value of ultrasonic shear wave elastography (SWE) and contrast-enhanced ultrasound (CEUS) in the differential diagnosis of patients with benign and malignant thyroid lesions. Methods Eighty-two patients with thyroid nodules (96 thyroid nodules) at our hospital were enrolled. All patients underwent ultrasonic SWE and CEUS examination. With surgical pathology as the gold standard, the Young's modulus, CEUS imaging features, and quantitative parameters were compared between the benign and malignant groups. The diagnostic efficiency of SWE, CEUS, and their combination was analyzed by receiver-operating characteristic curve (ROC). Results The average of the Young's modulus in the malignant group was significantly higher than that of the benign group (P<0.05). There were significant differences in the CEUS images of nodules between the benign and malignant groups in terms of boundary conditions, morphology, perfusion intensity, homogeneous enhancement, and perfusion defects (P<0.05), while there were no significant difference in initial increase time, peak intensity, time to peak, and area under the curve (P>0.05). The curve sharpness in the benign group was significantly lower than that of the malignant group (P<0.05). ROC analysis found that the diagnostic sensitivity and specificity of SWE, CEUS, and their combination were 90.1% and 81.6%, 67.8% and 75.4%, and 97.3% and 71.5%, respectively. Conclusions Compared with CEUS, the sensitivity and specificity of SWE were relatively higher in the differential diagnosis of benign and malignant thyroid lesions, and a combination of both can improve the diagnostic sensitivity of SWE alone to a certain extent.
Collapse
Affiliation(s)
- Jing Xu
- Department of Radiology, East Branch Hospital of Sichuan Provincial People's Hospital, Chengdu, China
| | - Ping Wang
- Department of Ultrasound, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Wensheng Yue
- Department of Ultrasound, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Yuqun Luo
- Department of Ultrasound, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Zukun Li
- Department of Ultrasound, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| |
Collapse
|
12
|
Liu BJ, Zhang YF, Zhao CK, Wang HX, Li MX, Xu HX. Conventional ultrasound characteristics, TI-RADS category and shear wave speed measurement between follicular adenoma and follicular thyroid carcinoma. Clin Hemorheol Microcirc 2020; 75:291-301. [PMID: 32280082 DOI: 10.3233/ch-190750] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The purpose of the study was to explore the differences of conventional ultrasound characteristics, thyroid imaging reporting and data system (TI-RADS) category and shear wave speed (SWS) measurement between follicular adenoma (FA) and follicular thyroid carcinoma (FTC). Twenty-eight FTCs and 67 FAs proven by surgery were retrospectively included for analysis. Conventional ultrasound and point-shear wave elastography (p-SWE) were performed in all of the included patients. The ultrasound features, American Thyroid Association (ATA) TI-RADS category and American College of Radiology (ACR) TI-RADS category, SWS measurement were compared between the two groups. Receiver operating characteristic (ROC) curve was performed and area under ROC curve (AUC) was obtained for significant features. There were no statistical differences in mean age (46.9±15.7years vs. 48.6±13.6years, P = 0.639), gender (9 males, 32.1% vs. 18 males, 29.0%, P = 0.766) and mean diameter (28.3±16.2 mm vs. 33.8±11.9 mm, P = 0.077) between FTCs and FAs. Hypoechogenicity, lobulated or irregular margin, macrocalcification were more common in FTCs than FAs (all P < 0.05). Mean SWS of FTCs (2.29±0.64 m/s) was slightly higher than that of FAs (1.94±0.68 m/s) (P = 0.023). The AUCs were 0.655, 0.744, and 0.744 with the cut-off SWS≥1.89 m/s, ACR TI-RADS category 4 and intermediate suspicion of ATA TI-RADS category. The sensitivity and AUC were 82.1% and 0.812 with combined ultrasound features of hypoechogenicity, lobulated or irregular margin and macrocalcification. In Conclusion, SWS measurement and TI-RADS categories were useful for the identification of FTCs from FAs.
Collapse
Affiliation(s)
- Bo-Ji Liu
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China.,Thyroid Institute, Tongji University School of Medicine, Shanghai, China.,Shanghai Center for Thyroid Diseases, Shanghai, China
| | - Yi-Feng Zhang
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China.,Thyroid Institute, Tongji University School of Medicine, Shanghai, China.,Shanghai Center for Thyroid Diseases, Shanghai, China
| | - Chong-Ke Zhao
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China.,Thyroid Institute, Tongji University School of Medicine, Shanghai, China.,Shanghai Center for Thyroid Diseases, Shanghai, China
| | - Han-Xiang Wang
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China.,Thyroid Institute, Tongji University School of Medicine, Shanghai, China.,Shanghai Center for Thyroid Diseases, Shanghai, China
| | - Ming-Xu Li
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China.,Thyroid Institute, Tongji University School of Medicine, Shanghai, China.,Shanghai Center for Thyroid Diseases, Shanghai, China
| | - Hui-Xiong Xu
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China.,Thyroid Institute, Tongji University School of Medicine, Shanghai, China.,Shanghai Center for Thyroid Diseases, Shanghai, China
| |
Collapse
|
13
|
Lu C, Wang Y, Yu M. Is ultrasonographic evaluation sensitive enough to detect multicentric papillary thyroid carcinoma? Gland Surg 2020; 9:737-746. [PMID: 32775264 DOI: 10.21037/gs-20-487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background This study aimed to investigate the preoperative ultrasonographic (US) evaluation of multicentric papillary thyroid carcinoma (PTC) and to evaluate the association of US findings with lymph node metastasis and extracapsular extension in PTC. Methods Preoperative US evaluations of patients with PTC who underwent total thyroidectomy were retrospectively investigated. Pathological perspectives and US features of PTC were analyzed. The sensitivity of US in detecting multicentric PTC was evaluated. Results The present study included 89 PTC patients who underwent total thyroidectomy. In total, 164 nodules were detected by preoperative US. Significant differences in US pattern were found between benign and malignant nodules. Of the 89 patients with PTC, 33 (37.08%) cases were confirmed as multicentric PTC by operation and pathological examination, 22 (66.67%) of which were bilateral. Before surgery, only 23 patients were suspected as multicentric PTC based on US findings. Pathological examination revealed that malignant nodules in 17 (51.51%) patients with multicentric PTC had been missed by preoperative US. The malignant nodules that went undetected by US were micronodulars (1-4 mm). Furthermore, ultrasonography was less sensitive for the diagnosis of metastatic lymph nodes in the neck. US had more than 80% sensitivity for detection of extracapsular extension of cases. Conclusions US evaluation is not sensitive enough to detect multicentric PTC. The minute size of some nodules in multicentric PTC, may lead to them being missed by US evaluation. Ultrasonography is an optional tool for the detection of extracapsular extension, but it is less sensitive for diagnosing lymph node metastasis.
Collapse
Affiliation(s)
- Congqing Lu
- Ultrasound Section, First People's Hospital, Lianyungang 222000, China
| | - Yan Wang
- Ultrasound Section, First People's Hospital, Lianyungang 222000, China
| | - Ming Yu
- Ultrasound Section, First People's Hospital, Lianyungang 222000, China
| |
Collapse
|
14
|
Wang J, He X, Ma L, Li M, Sun L, Jiang J, Zhou Q. Multimode ultrasonic technique is recommended for the differential diagnosis of thyroid cancer. PeerJ 2020; 8:e9112. [PMID: 32411540 PMCID: PMC7204870 DOI: 10.7717/peerj.9112] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Accepted: 04/10/2020] [Indexed: 12/14/2022] Open
Abstract
Background B-mode ultrasound is one of the most commonly used imaging techniques for evaluating thyroid nodules due to its noninvasive property and excellent performance in terms of discriminating between benign and malignant nodules. However, the accuracy of differential diagnosis strongly depends on the experience of ultrasonographers. In addition to B-mode ultrasound, the elastic mode and contrast-enhanced mode have shown complimentary value in the diagnosis of thyroid nodules. The combination of multiple modes in ultrasonic techniques may effectively undermine diagnostic subjectiveness and improve accuracy. In this study, we evaluated the diagnostic value of combining the three ultrasonic modes for differentiating thyroid cancers. Methods In this retrospective study, we analyzed a total of 196 thyroid nodules with suspected malignancies from 185 patients who gave informed consent. Xi’an Jiaotong University granted ethical approval (No. 2018200) to carry out the study within its facilities. All the patients received ultrasonic examinations with the B mode, elastic mode and contrast-enhanced mode, followed by histopathological confirmation by fine-need aspiration or surgery. A predictive multivariate logistic regression model was selected to integrate the variety of data obtained from the three modes. Results The combination of three ultrasonic techniques for differentiating malignant from benign thyroid nodules showed the highest diagnostic accuracy of 0.985 compared to the B mode alone (0.841) and the two-mode combination. The accuracy of the B mode combined with the elastic technique was 0.954, and the accuracy of the B mode combined with the contrast-enhanced technique was 0.960. Discussion Multimode ultrasonic techniques should be recommended to patients with suspected malignant thyroid nodules in routine clinical practice.
Collapse
Affiliation(s)
- Juan Wang
- Department of Ultrasound, The Second Affiliated Hospital, Medical School of Xi'an Jiaotong University, Xi'an, China
| | - Xin He
- Department of Ultrasound, The Second Affiliated Hospital, Medical School of Xi'an Jiaotong University, Xi'an, China
| | - Li Ma
- Department of Pathology, The Second Affiliated Hospital, Medical School of Xi'an Jiaotong University, Xi'an, China
| | - Miao Li
- Department of Ultrasound, The Second Affiliated Hospital, Medical School of Xi'an Jiaotong University, Xi'an, China
| | - Lei Sun
- Department of Ultrasound, The Second Affiliated Hospital, Medical School of Xi'an Jiaotong University, Xi'an, China
| | - Jue Jiang
- Department of Ultrasound, The Second Affiliated Hospital, Medical School of Xi'an Jiaotong University, Xi'an, China
| | - Qi Zhou
- Department of Ultrasound, The Second Affiliated Hospital, Medical School of Xi'an Jiaotong University, Xi'an, China
| |
Collapse
|
15
|
Zhang J, Zhang X, Meng Y, Chen Y. Contrast-enhanced ultrasound for the differential diagnosis of thyroid nodules: An updated meta-analysis with comprehensive heterogeneity analysis. PLoS One 2020; 15:e0231775. [PMID: 32310968 PMCID: PMC7170259 DOI: 10.1371/journal.pone.0231775] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Accepted: 03/31/2020] [Indexed: 12/16/2022] Open
Abstract
The diagnostic accuracy of contrast-enhanced ultrasound (CEUS) for distinguishing malignant thyroid nodules from benign thyroid nodules remains controversial. This meta-analysis was performed to evaluate the overall diagnostic value of CEUS for the characterization of thyroid nodules. Relevant studies were identified by searching PubMed, Embase and the Cochrane Library until August 1th 2019 to assess the overall diagnostic accuracy of CEUS. 37 eligible studies were included in the present meta-analysis. The pooled sensitivity, specificity, positive likelihood rate, negative likelihood rate and diagnostic odds ratio of CEUS were 0.87, 0.83, 5.38, 0.17 and 38.94, respectively, with the AUC of 0.9263. Subgroup analysis showed the heterogeneity was greatly reduced in small nodules group (≤ 1 cm) (I2 = 0.0%), while heterogeneity was still observed in the group of variable sizes group (I2 = 69.5%). However, meta-regression analysis revealed that only diagnostic criterion was the major source of heterogeneity (p = 0.0259). The risk of publication bias was negligible (p = 0.35). CEUS exhibited high accuracy for the identification of thyroid nodules and might provide additional perfusion information for the current US imaging reporting systems.
Collapse
Affiliation(s)
- Juanjuan Zhang
- Department of Ultrasound, Huaihe Hospital of Henan University, Henan, China
| | - Xiuting Zhang
- Department of Ultrasound, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yanna Meng
- Department of Ultrasound, Huaihe Hospital of Henan University, Henan, China
| | - Yinghong Chen
- Department of Ultrasound, Huaihe Hospital of Henan University, Henan, China
| |
Collapse
|
16
|
Yongfeng Z, Ping Z, Hong P, Wengang L, Yan Z. Superb microvascular imaging compared with contrast-enhanced ultrasound to assess microvessels in thyroid nodules. J Med Ultrason (2001) 2020; 47:287-297. [DOI: 10.1007/s10396-020-01011-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Accepted: 12/10/2019] [Indexed: 12/24/2022]
|
17
|
Xi X, Gao L, Wu Q, Fang S, Xu J, Liu R, Yang X, Zhu S, Zhao R, Lai X, Zhang X, Zhang B, Jiang Y. Differentiation of Thyroid Nodules Difficult to Diagnose With Contrast-Enhanced Ultrasonography and Real-Time Elastography. Front Oncol 2020; 10:112. [PMID: 32175270 PMCID: PMC7056834 DOI: 10.3389/fonc.2020.00112] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2019] [Accepted: 01/21/2020] [Indexed: 02/06/2023] Open
Abstract
According to the 2015 American Thyroid Association (ATA), referred risk stratification and thyroid nodules with intermediate- and low-suspicion patterns are difficult to diagnose. The objective of this study is to evaluate the diagnostic performance of contrast-enhanced ultrasonography (CEUS) and elastosonography (ES) for the differentiation of these thyroid nodules. From November 2011 to June 2016, a total of 163 thyroid nodules with intermediate- and low-suspicion patterns in 150 consecutive patients at our hospital were studied before surgery. With surgical pathology as the standard, the diagnostic value of CEUS and ES was analyzed. There were 29 (17.8%) malignant lesions and 134 (82.2%) benign lesions. The enhancement patterns of CEUS, the echogenicity, and the elastography were significantly different between malignant and benign lesions (P < 0.05). Heterogenous enhancement was more common in malignant nodules, and the sensitivity, specificity, positive predictive value, negative predictive value, and odds ratio were 51.7, 88.1, 48.4, 89.4, and 10.1%, respectively. The diagnostic accuracy of CEUS was better than the conventional ultrasound [area under the curve (AUC), 0.729 vs. 0.616, P = 0.021]. The enhancement patterns of CEUS were helpful in the differential diagnosis of thyroid nodules with intermediate and low suspicion.
Collapse
Affiliation(s)
- Xuehua Xi
- Department of Ultrasound, China-Japan Friendship Hospital, Beijing, China
| | - Luying Gao
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Qiong Wu
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.,Department of Ultrasound, Affiliated Hospital of Qingdao University, Qingdao, China
| | - Shibao Fang
- Department of Ultrasound, Affiliated Hospital of Qingdao University, Qingdao, China
| | - Jingzhu Xu
- Department of General Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Ruyu Liu
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Xiao Yang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Shenling Zhu
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Ruina Zhao
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Xingjian Lai
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Xiaoyan Zhang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Bo Zhang
- Department of Ultrasound, China-Japan Friendship Hospital, Beijing, China.,Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Yuxin Jiang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| |
Collapse
|
18
|
Trimboli P, Castellana M, Virili C, Havre RF, Bini F, Marinozzi F, D’Ambrosio F, Giorgino F, Giovanella L, Prosch H, Grani G, Radzina M, Cantisani V. Performance of contrast-enhanced ultrasound (CEUS) in assessing thyroid nodules: a systematic review and meta-analysis using histological standard of reference. Radiol Med 2020; 125:406-415. [DOI: 10.1007/s11547-019-01129-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 12/27/2019] [Indexed: 12/21/2022]
|
19
|
Xu T, Wu Y, Wu RX, Zhang YZ, Gu JY, Ye XH, Tang W, Xu SH, Liu C, Wu XH. Validation and comparison of three newly-released Thyroid Imaging Reporting and Data Systems for cancer risk determination. Endocrine 2019; 64:299-307. [PMID: 30474824 DOI: 10.1007/s12020-018-1817-8] [Citation(s) in RCA: 79] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 11/12/2018] [Indexed: 01/10/2023]
Abstract
PURPOSE To validate and compare diagnostic value of three newly-released Thyroid Imaging Reporting and Data Systems (TIRADS) for cancer risk determination. METHODS Total 2031 patients with 2465 thyroid nodules were recruited for this study. Ultrasound (US) images were categorized based on three TIRADS editions established by Korean Society of Thyroid Radiology (KSThR), European Thyroid Association (ETA) and American College of Radiology (ACR). ROC curves were established to compare diagnostic value. RESULTS Total 1460 benign and 1005 malignant nodules were enrolled. The malignancy rates of each category in KSThR-TIRADS were 2.8%, 5.1%, 33.7% and 79.6%, respectively. For European-TIRADS, 0, 3.1, 22.8, and 73.5% of nodules categorized as 2 to 5 were malignant. Distribution of carcinomas among ACR-TIRADS categories was 0%, 2.3%, 7.5%, 40.1% and 81.4%, respectively. In terms of diagnostic value, KSThR-TIRADS had highest AUC (0.855) and specificity (87.4%), while lowest (71.4%) sensitivity. ACR-TIRADS showed best sensitivity (96.6%) with lowest specificity (52.9%) and the AUC (0.846) was slightly lower than KSThR-TIRADS. Total 56.1, 45.4, and 37.4% fine-needle aspiration biopsy (FNAB) were recommended by KSThR, ETA and ACR, revealing 42.8%, 44.5% and 53.6% malignant lesions, respectively. The rate of unnecessary FNAB was lowest with the ACR (17.3%), followed by ETA (25.2%) and KSThR (32.1%). CONCLUSION All these US models showed great value in predicting thyroid malignancy. Among them, KSThR-TIRADS showed the most effective diagnostic performance in specificity, while ACR-TIRADS yielded best sensitivity. As for FNAB criteria, ACR-TIRADS showed the lowest rate of unnecessary FNAB and highest rate of malignancy in FNAB.
Collapse
Affiliation(s)
- Ting Xu
- Department of Endocrinology, Jiangsu Province Official Hospital, Nanjing, China
| | - Ya Wu
- Department of Endocrinology, the First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Run-Xin Wu
- Nanjing Foreign Languages School, Nanjing, China
| | - Yu-Zhi Zhang
- Department of Ultrasound, Jiangsu Province Hospital on Integration of Chinese and Western Medicine, Nanjing, China
| | - Jing-Yu Gu
- Department of Endocrinology, the First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Xin-Hua Ye
- Department of Ultrasound, the First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Wei Tang
- Department of Endocrinology, Jiangsu Province Official Hospital, Nanjing, China
| | - Shu-Hang Xu
- Department of Endocrinology, Jiangsu Province Hospital on Integration of Chinese and Western Medicine, Nanjing, China
| | - Chao Liu
- Department of Endocrinology, Jiangsu Province Hospital on Integration of Chinese and Western Medicine, Nanjing, China
| | - Xiao-Hong Wu
- Department of Endocrinology, the First Affiliated Hospital with Nanjing Medical University, Nanjing, China.
| |
Collapse
|
20
|
Xu Y, Qi X, Zhao X, Ren W, Ding W. Clinical diagnostic value of contrast-enhanced ultrasound and TI-RADS classification for benign and malignant thyroid tumors: One comparative cohort study. Medicine (Baltimore) 2019; 98:e14051. [PMID: 30681562 PMCID: PMC6358332 DOI: 10.1097/md.0000000000014051] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 11/21/2018] [Accepted: 12/14/2018] [Indexed: 02/06/2023] Open
Abstract
To evaluate the diagnostic efficacy and clinical value of contrast-enhanced ultrasonography (CEUS) plus TI-RADS classification in benign and malignant thyroid tumors compared with either method alone.The informed consent was signed all patients. A total of 370 patients with thyroid tumors of TI-RADS category 3 and 4 were recruited, with 432 thyroid nodules. They respectively received routine ultrasonography and CEUS. The nodules were reclassified according to CEUS scoring, and a combined diagnosis was made. The pathological results were taken as the gold standard. The sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and area under the ROC curve were calculated for the 3 diagnostic methods. The diagnostic efficacy was compared by using Student t test, Pearson chi-square (χ) test, McNemar chi-square (χ) test or Z test. Student t test and logistic regression were employed for comparing different imaging features of benign and malignant thyroid tumors on CEUS and risk analysis.Of 432 thyroid nodules, there were 258 malignant nodules (59.72%) and 174 benign ones (40.28%). By logistic regression, 6 suspicious features on CEUS were considered significant for differentiating malignant from benign tumors: slow entry of contrast agents during enhancement stage (OR = 15.610, P = .001), slow time to peak (OR = 7.416, P = .002), non-uniform enhancement (OR = 10.076, P = .023), enhancement pattern (irregular) (OR = 36.233, P = .002), enhancement boundary (unclear) (OR = 25.300, P = .012), and no ring-like enhancement (OR = 25.297, P = .004). CEUS plus TI-RADS classification showed a higher diagnostic efficacy for differentiating between benign and malignant thyroid tumors. The Se was 85.66% (0.806-0.896), Sp 83.33% (0.768-0.884), PPV 88.40% (0.836-0.919), NPV 79.67% (0.729-0.851), and AUC 0.867 ± 0.019 (0.815-0.889). The above indicators were of statistical significance as compared with TI-RADS classification or CEUS alone (P <.05).CEUS can more clearly visualize microvascular distribution of the nodules and offers a new approach to diagnose benign and malignant thyroid tumors. TI-RADS classification plus CEUS is more accurate than TI-RADS classification alone. This combined approach is worthy of clinical popularization.
Collapse
|
21
|
Liu Q, Cheng J, Li J, Gao X, Li H. The diagnostic accuracy of contrast-enhanced ultrasound for the differentiation of benign and malignant thyroid nodules: A PRISMA compliant meta-analysis. Medicine (Baltimore) 2018; 97:e13325. [PMID: 30544392 PMCID: PMC6310493 DOI: 10.1097/md.0000000000013325] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Contrast-enhanced ultrasound (CEUS) is a non-invasive method that has been used in the diagnosis of several diseases. Recently, CEUS has been used in the differentiation of benign and malignant thyroid nodules. However, the performance of CEUS in thyroid nodules has not been studied clearly. METHODS The databases of Pubmed, Embase, Cochrane library and the unpublished studies were systematically searched for candidate inclusions, with the use of CEUS in differentiating the benign and malignant thyroid nodules. The quality of included studies was assessed using Quality Assessment of Diagnostic Accuracy Studies (QUADAS) questionnaire. The pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), positive and negative likelihood ratio (NLR) were calculated using STATA software version 14.0. RESULTS Totally 33 diagnostic studies were included for further analysis. The quality of included studies was relatively high using QUADAS method. The pooled estimates of sensitivity and specificity were 0.88 (95% CI 0.85, 0.91) and 0.88 (95% CI 0.83, 0.91), respectively. In addition, the DOR, the positive and NLRs were pooled positive LR and the negative LR were 54 (95% CI 33, 89), 7.1% (5.2%, 9.8%), and 0.13% (0.10%, 0.18%). No significant publication bias was observed. CONCLUSIONS Our meta-analysis further indicated that CEUS is a useful tool in differentiating benign and malignant thyroid nodules, with high sensitivity and specificity.
Collapse
Affiliation(s)
| | | | | | | | - Hongbo Li
- Department of General Surgery, People's Hospital of Rizhao, Rizhao, China
| |
Collapse
|
22
|
Cheng Y, Wang M, Ma B, Ma X. Potential role of contrast-enhanced ultrasound for the differentiation of malignant and benign gallbladder lesions in East Asia: A meta-analysis and systematic review. Medicine (Baltimore) 2018; 97:e11808. [PMID: 30113470 PMCID: PMC6112946 DOI: 10.1097/md.0000000000011808] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND The purpose of this study was to systematically review and evaluate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in differentiating malignant and benign gallbladder lesions. METHODS We conducted a comprehensive search on PubMed, Embase, and Cochrane Library for all potential relevant articles published before December 2017. The pooled sensitivity, specificity, diagnostic odds ratio (DOR) and area under the curve (AUC) of summary receiver operating characteristic (SROC) were calculated by Meta-Disc Version 1.4 and STATA 12.0. RESULTS Twelve eligible studies were included in our study. A total of 1044 patients were assessed. The pooled sensitivity and specificity were 0.81 (95% confidence interval [CI], 0.77-0.84; inconsistency index [I] = 84.5%) and 0.87 (95% CI, 0.85-0.89; I = 94.4%), respectively. The pooled DOR was 58.84 (95% CI, 32.39-106.88; I = 51.9%). The AUC was 0.9371. According to Deek funnel plot asymmetry test, there was no significant publication bias (P = .31). CONCLUSIONS The results yielded from the available evidence suggest that CEUS is a promising and adjuvant imaging technique to conventional ultrasound for the differential diagnosis of benign and malignant gallbladder lesions.
Collapse
Affiliation(s)
- Yuan Cheng
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University and Collaborative Innovation Center
| | - Manni Wang
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University and Collaborative Innovation Center
| | - Buyun Ma
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Xuelei Ma
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University and Collaborative Innovation Center
| |
Collapse
|
23
|
|
24
|
Lei Z, Lou J, Bao L, Lv Z. Contrast-enhanced ultrasound for needle biopsy of central lung cancer with atelectasis. J Med Ultrason (2001) 2017; 45:461-467. [PMID: 29243129 DOI: 10.1007/s10396-017-0851-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2017] [Accepted: 11/10/2017] [Indexed: 12/28/2022]
Abstract
PURPOSE Contrast-enhanced ultrasound (CEUS) can distinguish between central lung cancer and atelectatic lung tissue. The aim of this study was to explore the clinical value of CEUS for biopsy in patients with central lung cancer with obstructive atelectasis. METHODS One hundred and twelve patients were selected and CEUS was performed to display central lung cancer and atelectatic lung tissue. The front edge of central lung cancer was punctured with a needle, avoiding the necrotic area, under the guidance of CEUS. RESULTS All of the 112 lesions were diagnosed with a clear central lung cancer mass and atelectatic lung tissue. In 104 cases, the central lung cancer mass presented with a "slow-in and fast-out" pattern compared to atelectatic lung tissue. In eight cases, the central lung cancer mass presented with a "fast-in and fast-out" pattern compared to atelectatic lung tissue. The mean number of punctures was 2.6, and the success rate of puncture biopsy was 98%. Of the 112 patients, six cases had hemoptysis during the procedure and 10 patients had bloody sputum in the postoperative period. No complications were found in the other cases. CONCLUSION CEUS has important clinical value for needle biopsy of central lung cancer with atelectasis.
Collapse
Affiliation(s)
- Zhikai Lei
- Department of Ultrasound, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, Zhejiang, China.
| | - Jun Lou
- Department of Ultrasound, Hangzhou Tumor Hospital, Hangzhou, China
| | - Lingyun Bao
- Department of Ultrasound, Hangzhou First People's Hospital, Hangzhou, China
| | - Zhuying Lv
- Department of Ultrasound, Hangzhou Tumor Hospital, Hangzhou, China
| |
Collapse
|
25
|
Sonographic Features of Cervical Lymph Nodes in Patients With Hashimoto Thyroiditis and the Impacts From the Levothyroxine With Prednisone Therapy. Ultrasound Q 2017; 34:67-70. [PMID: 29112639 DOI: 10.1097/ruq.0000000000000324] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE This study aimed to evaluate the ultrasonographic pattern of cervical lymph nodes (CLNs) and whether levothyroxine with prednisone therapy is effective for lymphadenopathy in patients with Hashimoto thyroiditis (HT). METHODS This retrospective study was looking at patients with confirmed diagnosis of HT who underwent comprehensive neck ultrasound examination. We reviewed sonographic findings in 127 patients with HT, 234 euthyroid patients with goiter, and 122 healthy subjects. In addition, 30 untreated HT patients with cervical lymphadenopathy were recruited for the levothyroxine with prednisone therapy. We rescanned the patients 9 months after treatment with levothyroxine and prednisone. RESULTS Patients with HT had a higher rate of CLN detection on ultrasound than euthyroid patients with goiter and healthy subjects at cervical levels III, IV, and VI (P < 0.01). In addition, patients with HT had a higher rate of detection of CLNs with abnormal sonographic features than the other 2 groups, most notably at cervical levels III, IV, and VI (P < 0.01). After the treatment, the mean thyroid volume, thyroid nodule volume, CLN volume, symptom score, and cosmetic grade of 30 HT patients were remarkably decreased (P < 0.01 or P < 0.001). CONCLUSIONS Hashimoto thyroiditis seems to be associated with an increased rate of detection of CLNs with abnormal sonographic features, particularly at cervical levels III, IV, and VI. Therapy with levothyroxine with prednisone is effective for cervical lymphadenopathy in patients with HT.
Collapse
|
26
|
Wang Y, Lei KR, He YP, Li XL, Ren WW, Zhao CK, Bo XW, Wang D, Sun CY, Xu HX. Malignancy risk stratification of thyroid nodules: comparisons of four ultrasound Thyroid Imaging Reporting and Data Systems in surgically resected nodules. Sci Rep 2017; 7:11560. [PMID: 28912438 PMCID: PMC5599531 DOI: 10.1038/s41598-017-11863-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Accepted: 08/30/2017] [Indexed: 01/23/2023] Open
Abstract
To compare the efficiency of four different ultrasound (US) Thyroid Imaging Reporting and Data Systems (TI-RADS) in malignancy risk stratification in surgically resected thyroid nodules (TNs). The study included 547 benign TNs and 464 malignant TNs. US images of the TNs were retrospectively reviewed and categorized according to the TI-RADSs published by Horvath E et al. (TI-RADS H), Park et al. (TI-RADS P), Kwak et al. (TI-RADS K) and Russ et al. (TI-RADS R). The diagnostic performances for the four TI-RADSs were then compared. At multivariate analysis, among the suspicious US features, marked hypoechogenicity was the most significant independent predictor for malignancy (OR: 15.344, 95% CI: 5.313-44.313) (P < 0.05). Higher sensitivity was seen in TI-RADS H, TI-RADS K, TI-RADS R comparing with TI-RADS P (P < 0.05 for all), whereas the specificity, accuracy and area under the ROC curve (Az) of TI-RADS P were the highest (all P < 0.05). Higher specificity, accuracy and Az were seen in TI-RADS K compared with TI-RADS R (P = 0.003). With its higher sensitivity, TI-RADS K, a simple predictive model, is practical and convenient for the management of TNs in clinical practice. The study indicates that there is a good concordance between TI-RADS categories and histopathology.
Collapse
Affiliation(s)
- Ying Wang
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Department of Medical Ultrasound, Yangpu Hospital, Tongji University School of Medicine, Shanghai, 200090, China
- Thyroid Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Shanghai Center for Thyroid Diseases, Shanghai, 200072, China
| | - Kai-Rong Lei
- Department of Medical Ultrasound, Yangpu Hospital, Tongji University School of Medicine, Shanghai, 200090, China
| | - Ya-Ping He
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Shanghai Center for Thyroid Diseases, Shanghai, 200072, China
| | - Xiao-Long Li
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Thyroid Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Shanghai Center for Thyroid Diseases, Shanghai, 200072, China
| | - Wei-Wei Ren
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Thyroid Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Shanghai Center for Thyroid Diseases, Shanghai, 200072, China
| | - Chong-Ke Zhao
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Thyroid Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Shanghai Center for Thyroid Diseases, Shanghai, 200072, China
| | - Xiao-Wan Bo
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Thyroid Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Shanghai Center for Thyroid Diseases, Shanghai, 200072, China
| | - Dan Wang
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Thyroid Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Shanghai Center for Thyroid Diseases, Shanghai, 200072, China
| | - Cheng-Yu Sun
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Department of Medical Ultrasound, Yangpu Hospital, Tongji University School of Medicine, Shanghai, 200090, China
- Thyroid Institute, Tongji University School of Medicine, Shanghai, 200072, China
- Shanghai Center for Thyroid Diseases, Shanghai, 200072, China
| | - Hui-Xiong Xu
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, 200072, China.
- Thyroid Institute, Tongji University School of Medicine, Shanghai, 200072, China.
- Shanghai Center for Thyroid Diseases, Shanghai, 200072, China.
| |
Collapse
|
27
|
Prospective validation of the ultrasound based TIRADS (Thyroid Imaging Reporting And Data System) classification: results in surgically resected thyroid nodules. Eur Radiol 2016; 27:2619-2628. [DOI: 10.1007/s00330-016-4605-y] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 08/28/2016] [Accepted: 09/07/2016] [Indexed: 02/07/2023]
|