1
|
Boutté Y, Grebe M. Immunocytochemical fluorescent in situ visualization of proteins in Arabidopsis. Methods Mol Biol 2014; 1062:453-72. [PMID: 24057381 DOI: 10.1007/978-1-62703-580-4_24] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The understanding of cellular and subcellular functions often relies on the ability to visualize proteins as close as possible to their endogenous locations. A number of immunocytochemical techniques have been developed to detect proteins in situ using specific antibodies raised against proteins of interest. Here, we describe in detail two protocols commonly, successfully employed in Arabidopsis research. The first allows for immunolocalization of proteins in whole-mount Arabidopsis roots without the need for physical sectioning. The second allows for immunolocalization of proteins on semi-thin microtome sections of wax-embedded swamples. This approach is particularly useful when sectioning of Arabidopsis roots or other thicker plant organs is required for immunolocalization. We provide step-by-step protocols with extensive troubleshooting for both the whole-mount and sectioning protocols. Furthermore, critical steps, advantages, and limitations of the two protocols described here are discussed.
Collapse
Affiliation(s)
- Yohann Boutté
- Department of Forest Genetics and Plant Physiology, UPSC, Swedish University of Agricultural Sciences, Umeå, Sweden
| | | |
Collapse
|
2
|
Abstract
This chapter briefly describes conventional and microwave-assisted chemical fixation methods, as well as cryo-specimen preparation techniques for studying the cellular and organelle ultrastructure of plant tissues under transmission electron microscopy. The general methods and procedures for the plant specimen preparation (including fixation, dehydration, resin infiltration, and embedding) are similar to those for animal tissues. However, certain special characteristic features of plant tissues such as thick cellulosic cell wall, waxy substance in the cuticle, large amount of gases in the intercellular spaces, and the presence of vacuoles have created fixation and resin filtration difficulties. Specific modifications of the protocols used for animal tissues are therefore required, such as the application of vacuum during the initial fixation and resin infiltration stage to remove gases from the tissues and resin. Microwave-assisted procedure can reduce specimen preparation time, but both conventional and microwave-assisted chemical fixation procedures produce artifacts. Cryo-specimen preparation involves with high-pressure freezing and freeze-substitution can minimize artifact formation, but their application to highly vacuolated, thick-walled plant cells is limited.
Collapse
Affiliation(s)
- John Kuo
- Centre for Microscopy, Characterization and Analysis, The University of Western Australia, Crawley, WA, Australia
| |
Collapse
|
3
|
Nic-Can G, Hernández-Castellano S, Kú-González A, Loyola-Vargas VM, De-la-Peña C. An efficient immunodetection method for histone modifications in plants. PLANT METHODS 2013; 9:47. [PMID: 24341414 PMCID: PMC3868413 DOI: 10.1186/1746-4811-9-47] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Accepted: 12/02/2013] [Indexed: 05/08/2023]
Abstract
BACKGROUND Epigenetic mechanisms can be highly dynamic, but the cross-talk among them and with the genome is still poorly understood. Many of these mechanisms work at different places in the cell and at different times of organism development. Covalent histone modifications are one of the most complex and studied epigenetic mechanisms involved in cellular reprogramming and development in plants. Therefore, the knowledge of the spatial distribution of histone methylation in different tissues is important to understand their behavior on specific cells. RESULTS Based on the importance of epigenetic marks for biology, we present a simplified, inexpensive and efficient protocol for in situ immunolocalization on different tissues such as flowers, buds, callus, somatic embryo and meristematic tissue from several plants of agronomical and biological importance. Here, we fully describe all the steps to perform the localization of histone modifications. Using this method, we were able to visualize the distribution of H3K4me3 and H3K9me2 without loss of histological integrity of tissues from several plants, including Agave tequilana, Capsicum chinense, Coffea canephora and Cedrela odorata, as well as Arabidopsis thaliana. CONCLUSIONS There are many protocols to study chromatin modifications; however, most of them are expensive, difficult and require sophisticated equipment. Here, we provide an efficient protocol for in situ localization of histone methylation that dispenses with the use of expensive and sensitive enzymes. The present method can be used to investigate the cellular distribution and localization of a wide array of proteins, which could help to clarify the biological role that they play at specific times and places in different tissues of various plant species.
Collapse
Affiliation(s)
- Geovanny Nic-Can
- Unidad de Bioquímica y Biología Molecular de Plantas, Centro de Investigación Científica de Yucatán, Calle 43 No. 130, Col. Chuburná de Hidalgo, Mérida CP 97200, Yucatán, México
| | - Sara Hernández-Castellano
- Unidad de Biotecnología, Centro de Investigación Científica de Yucatán, Calle 43 No. 130, Col. Chuburná de Hidalgo, Mérida CP 97200, Yucatán, México
| | - Angela Kú-González
- Unidad de Bioquímica y Biología Molecular de Plantas, Centro de Investigación Científica de Yucatán, Calle 43 No. 130, Col. Chuburná de Hidalgo, Mérida CP 97200, Yucatán, México
| | - Víctor M Loyola-Vargas
- Unidad de Bioquímica y Biología Molecular de Plantas, Centro de Investigación Científica de Yucatán, Calle 43 No. 130, Col. Chuburná de Hidalgo, Mérida CP 97200, Yucatán, México
| | - Clelia De-la-Peña
- Unidad de Biotecnología, Centro de Investigación Científica de Yucatán, Calle 43 No. 130, Col. Chuburná de Hidalgo, Mérida CP 97200, Yucatán, México
| |
Collapse
|
4
|
Zellnig G, Möstl S, Zechmann B. Rapid immunohistochemical diagnosis of tobacco mosaic virus disease by microwave-assisted plant sample preparation. Microscopy (Oxf) 2013; 62:547-53. [PMID: 23580761 PMCID: PMC4030761 DOI: 10.1093/jmicro/dft022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Accepted: 03/20/2013] [Indexed: 11/12/2022] Open
Abstract
Immunoelectron microscopy is a powerful method to diagnose viral diseases and to study the distribution of the viral agent within plant cells and tissues. Nevertheless, current protocols for the immunological detection of viral diseases with transmission electron microscopy (TEM) in plants take between 3 and 6 days and are therefore not suited for rapid diagnosis of virus diseases in plants. In this study, we describe a method that allows rapid cytohistochemical detection of tobacco mosaic virus (TMV) in leaves of tobacco plants. With the help of microwave irradiation, sample preparation of the leaves was reduced to 90 min. After sample sectioning, virus particles were stained on the sections by immunogold labelling of the viral coat protein, which took 100 min. After investigation with the TEM, a clear visualization of TMV in tobacco cells was achieved altogether in about half a day. Comparison of gold particle density by image analysis revealed that samples prepared with the help of microwave irradiation yielded significantly higher gold particle density as samples prepared conventionally at room temperature. This study clearly demonstrates that microwave-assisted plant sample preparation in combination with cytohistochemical localization of viral coat protein is well suited for rapid diagnosis of plant virus diseases in altogether about half a day by TEM.
Collapse
Affiliation(s)
| | | | - Bernd Zechmann
- Institute of Plant Sciences, University of Graz, Schubertstrasse 51, 8010 Graz, Austria
| |
Collapse
|
5
|
Carpentier A, Abreu S, Trichet M, Satiat-Jeunemaitre B. Microwaves and tea: new tools to process plant tissue for transmission electron microscopy. J Microsc 2012; 247:94-105. [PMID: 22681535 DOI: 10.1111/j.1365-2818.2012.03626.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Optimizing sample processing, reducing the duration of the preparation of specimen, and adjusting procedures to adhere to new health and safety regulations, are the current challenges of plant electron microscopists. To address these issues, plant processing protocols for TEM, combining the use of polyphenolic compounds as substitute for uranyl acetate with microwave technology are being developed. In the present work, we optimized microwave-assisted processing of different types of plant tissue for ultrastuctural and immunocytochemical studies. We also explored Oolong tea extract as alternative for uranyl acetate for the staining of plant samples. We obtained excellent preservation of cell ultrastructure when samples were embedded in epoxy resin, and of cell antigenicity, when embedded in LR-White resin. Furthermore, Oolong tea extract successfully replaced uranyl acetate as a counterstain on ultrathin sections, and for in block staining. These novel protocols reduce the time spent at the bench, and improve safety conditions for the investigator. The preservation of the cell components when following these approaches is of high quality. Altogether, they offer significant simplification of the procedures required for electron microscopy of plant ultrastructure.
Collapse
Affiliation(s)
- Anaïs Carpentier
- Laboratoire Dynamique de la Compartimentation Cellulaire, CNRS UPR2355/IFR87, Institut des Sciences du Végétal, Centre de Recherche de Gif (FRC3115), 91198, Gif-sur-Yvette Cedex, France
| | | | | | | |
Collapse
|
6
|
Zechmann B, Graggaber G, Zellnig G. Microwave assisted rapid diagnosis of plant virus diseases by transmission electron microscopy. J Vis Exp 2011:e2950. [PMID: 22025001 PMCID: PMC3227200 DOI: 10.3791/2950] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Investigations of ultrastructural changes induced by viruses are often necessary to clearly identify viral diseases in plants. With conventional sample preparation for transmission electron microscopy (TEM) such investigations can take several days and are therefore not suited for a rapid diagnosis of plant virus diseases. Microwave fixation can be used to drastically reduce sample preparation time for TEM investigations with similar ultrastructural results as observed after conventionally sample preparation. Many different custom made microwave devices are currently available which can be used for the successful fixation and embedding of biological samples for TEM investigations. In this study we demonstrate on Tobacco Mosaic Virus (TMV) infected Nicotiana tabacum plants that it is possible to diagnose ultrastructural alterations in leaves in about half a day by using microwave assisted sample preparation for TEM. We have chosen to perform this study with a commercially available microwave device as it performs sample preparation almost fully automatically in contrast to the other available devices where many steps still have to be performed manually and are therefore more time and labor consuming. As sample preparation is performed fully automatically negative staining of viral particles in the sap of the remaining TMV-infected leaves and the following examination of ultrastructure and size can be performed during fixation and embedding.
Collapse
|
7
|
Mary I, Oliver A, Skipp P, Holland R, Topping J, Tarran G, Scanlan DJ, O'Connor CD, Whiteley AS, Burkill PH, Zubkov MV. Metaproteomic and metagenomic analyses of defined oceanic microbial populations using microwave cell fixation and flow cytometric sorting. FEMS Microbiol Ecol 2010; 74:10-8. [PMID: 20618860 DOI: 10.1111/j.1574-6941.2010.00927.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
A major obstacle in the molecular investigation of natural, especially oceanic, microbial cells is their adequate preservation for further land-based molecular analyses. Here, we examined the use of microwaves for cell fixation before high-speed flow cytometric sorting to define the metaproteomes and metagenomes of key microbial populations. The microwave fixation procedure was established using cultures of Synechococcus cyanobacteria, the photosynthetic eukaryote Micromonas pusilla and the gammaproteobacterium Halomonas variabilis. Shotgun proteomic analyses showed that the profile of microwave-fixed and -unfixed Synechococcus sp. WH8102 cells was the same, and hence proteome identification of microwave-fixed sorted cells by nanoLC-MS/MS is possible. Microwave-fixed flow-sorted Synechococcus cells can also be successfully used for whole-genome amplification and fosmid library construction. We then carried out successful metaproteomic and metagenomic analyses of microwave-fixed Synechococcus cells flow sorted from concentrates of microbial cells, collected in the North Atlantic Ocean. Thus, the microwave fixation procedure developed appears to be useful for molecular studies of microbial populations in aquatic ecosystems.
Collapse
|
8
|
Matía I, González-Camacho F, Herranz R, Kiss JZ, Gasset G, van Loon JJWA, Marco R, Javier Medina F. Plant cell proliferation and growth are altered by microgravity conditions in spaceflight. JOURNAL OF PLANT PHYSIOLOGY 2010; 167:184-93. [PMID: 19864040 DOI: 10.1016/j.jplph.2009.08.012] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2009] [Revised: 08/24/2009] [Accepted: 08/25/2009] [Indexed: 05/20/2023]
Abstract
Seeds of Arabidopsis thaliana were sent to space and germinated in orbit. Seedlings grew for 4d and were then fixed in-flight with paraformaldehyde. The experiment was replicated on the ground in a Random Positioning Machine, an effective simulator of microgravity. In addition, samples from a different space experiment, processed in a similar way but fixed in glutaraldehyde, including a control flight experiment in a 1g centrifuge, were also used. In all cases, comparisons were performed with ground controls at 1g. Seedlings grown in microgravity were significantly longer than the ground 1g controls. The cortical root meristematic cells were analyzed to investigate the alterations in cell proliferation and cell growth. Proliferation rate was quantified by counting the number of cells per millimeter in the specific cell files, and was found to be higher in microgravity-grown samples than in the control 1g. Cell growth was appraised through the rate of ribosome biogenesis, assessed by morphological and morphometrical parameters of the nucleolus and by the levels of the nucleolar protein nucleolin. All these parameters showed a depletion of the rate of ribosome production in microgravity-grown samples versus samples grown at 1g. The results show that growth in microgravity induces alterations in essential cellular functions. Cell growth and proliferation, which are strictly associated functions under normal ground conditions, appeared divergent after gravity modification; proliferation was enhanced, whereas growth was depleted. We suggest that the cause of these changes could be an alteration in the cell cycle regulation, at the levels of checkpoints regulating cell cycle progression, leading to a shortened G2 period.
Collapse
Affiliation(s)
- Isabel Matía
- Centro de Investigaciones Biológicas (CSIC), Ramiro de Maeztu 9, E-28040 Madrid, Spain
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Zechmann B, Zellnig G. Rapid diagnosis of plant virus diseases by transmission electron microscopy. J Virol Methods 2009; 162:163-9. [PMID: 19665483 DOI: 10.1016/j.jviromet.2009.07.032] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2009] [Revised: 07/27/2009] [Accepted: 07/30/2009] [Indexed: 10/20/2022]
Abstract
A clear and rapid diagnosis of plant virus diseases is of great importance for agriculture and scientific experiments in plant phytopathology. Even though negative staining and transmission electron microscopy (TEM) are often used for detection and identification of viral particles and provide rapid and reliable results, it is necessary to examine ultrastructural changes induced by viruses for clear identification of the disease. With conventional sample preparation for TEM it can take several days to obtain ultrastructural results and it is therefore not suitable for rapid diagnosis of virus diseases of plants. The use of microwave irradiation can reduce the time for sample preparation for TEM investigations. Two model virus-plant systems [Nicotiana tabacum plants infected with Tobacco mosaic virus (TMV), Cucurbita pepo plants infected with Zucchini yellow mosaic virus (ZYMV)] demonstrate that it is possible to diagnose ultrastructural alterations induced by viruses in less than half a day by using microwave irradiation for preparation of samples. Negative staining of the sap of plants infected with TMV and ZYMV and the examination of ultrastructure and size were also carried out during sample preparation thus permitting diagnosis of the viral agent by TEM in a few hours. These methods will contribute towards a rapid and clear identification of virus diseases of plants and will be useful for diagnostic purposes in agriculture and in plant phytopathology.
Collapse
Affiliation(s)
- Bernd Zechmann
- University of Graz, Institute of Plant Sciences, Schubertstrasse 51, 8010 Graz, Austria.
| | | |
Collapse
|
10
|
Zechmann B, Zellnig G. Microwave-assisted rapid plant sample preparation for transmission electron microscopy. J Microsc 2009; 233:258-68. [PMID: 19220692 DOI: 10.1111/j.1365-2818.2009.03116.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The preparation of plant leaf material for transmission electron microscopical investigations can be a very time- and labour-consuming task as the reagents infiltrate the samples quite slowly and as usually most steps have to be performed manually. Fixation, buffer washes, dehydration, resin infiltration and polymerization of the resin-infiltrated leaf samples can take several days before the specimen can be cut ultrathin and used for ultrastructural investigations. In this study, we present a microwave-assisted automated sample preparation procedure that reduces preparation time from at least 3 days to about 5 h - with only a few steps that have to be performed manually - until the plant sample can be ultrathin sectioned and observed with the transmission electron microscope. For studying the efficiency of this method we have compared the ultrastructure of different leaf material (Arabidopsis thaliana, Nicotiana tabacum and Picea abies) which was prepared with a conventional, well-established chemical fixation and embedding protocol and a commercially available automated microwave tissue processor. Despite the massive reduction in sample preparation time no negative effects on cutting properties of the blocks, stability of the sections in the electron beam, contrast and ultrastructure of the cells were observed under the transmission electron microscope when samples were prepared with the microwave-assisted protocol. Additionally, no negative effects were detected on the dimensions of fine structures of grana stacks (including membranes, inter- and intrathylakoidal spaces), the nuclear envelope and the plasma membrane as the diameter of these structural components did not differ between leaf samples (of the same species) that were processed with the automated microwave tissue processor or by conventional fixation and embedding at room temperature.
Collapse
Affiliation(s)
- B Zechmann
- University of Graz, Institute of Plant Sciences, Schubertstrasse 51, 8010 Graz, Austria.
| | | |
Collapse
|
11
|
Schroeder JA, Gelderblom HR, Hauroeder B, Schmetz C, Milios J, Hofstaedter F. Microwave-assisted tissue processing for same-day EM-diagnosis of potential bioterrorism and clinical samples. Micron 2006; 37:577-90. [PMID: 16843832 PMCID: PMC7126925 DOI: 10.1016/j.micron.2005.11.015] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2005] [Revised: 11/25/2005] [Accepted: 11/26/2005] [Indexed: 11/25/2022]
Abstract
The purpose of this study was to explore the turnaround times, section and image quality of a number of more “difficult” specimens destined for rapid diagnostic electron microscopy (EM) after microwave-assisted processing. The results were assessed and compared with those of conventionally processed samples. A variety of infectious agents, some with a potential for bioterrorism, and liver biopsies serving as an example for routine histopathology samples were studied. The samples represented virus-producing cell cultures (such as SARS-coronavirus, West Nile virus, Orthopox virus), bacteria suspensions (cultures of Escherichia coli and genetically knockout apathogenic Bacillus anthracis), suspensions of parasites (malaria Plasmodium falciparum, Leishmania major, Microsporidia cuniculi, Caenorhabditis elegans), and whole Drosophila melanogaster flies infected with microsporidia. Fresh liver samples and infected flies were fixed in Karnovsky-fixative by microwaving (20 min), all other samples were fixed in buffered glutaraldehyde or Karnovsky-fixative overnight or longer. Subsequently, all samples were divided to evaluate alternative processing protocols: one part of the sample was OsO4-postfixed, ethanol-dehydrated, Epon-infiltrated (overnight) in an automated tissue processor (LYNX, Leica), and polymerized at 60 °C for 48 h; in parallel the other part was microwave-assisted processed in the bench microwave device (REM, Milestone), including post-osmication and the resin block polymerization. The microwave-assisted processing protocol required at minimum 3 h 20 min: the respective epon resin blocks were uniformly polymerized allowing an easy sectioning of semi- and ultrathin sections. Sections collected on non-coated 200 mesh grids were stable in the electron beam and showed an excellent preservation of the ultrastructure and high contrast, thus allowing an easy, unequivocal and rapid assessment of specimens. Compared with conventional routine methods, microwave technology facilitates a significant reduction in sample processing time from days to hours without any loss in ultrastructural details. Microwave-assisted processing could, therefore, be a substantial benefit for the routine electron microscopic diagnostic workload. Due to its speed and robust performance it could be applied wherever a rapid electron microscopy diagnosis is required, e.g., if bioterrorism or emerging agents are suspected. Combining microwave technology with digital image acquisition, the 1-day diagnosis based on ultrathin section electron microscopy will become possible, with crucial or interesting findings being consulted or shared worldwide with experts using modern telemicroscopy tools via Internet.
Collapse
Affiliation(s)
- Josef A Schroeder
- Central EM Laboratory, Pathology Department, University Hospital Regensburg, D-93053 Regensburg, Germany.
| | | | | | | | | | | |
Collapse
|