[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 07/17/2022] [Accepted: 07/21/2022] [Indexed: 02/03/2023]
Abstract
INTRODUCTION
There is no "gold standard" for the type of plate to be used for distal extra-articular humeral fractures; the most used is plating of each column. The objective was to evaluate the short-term clinical and radiological results of a Y- anatomical and innovative locking plate (YALP).
HYPOTHESIS
The hypothesis is: this anatomical and innovative locking plate will produce satisfactory and reliable results on extra-articular distal humerus fracture superior to double plate fixation.
MATERIALS AND METHODS
In a retrospective observational multicenter study, all patients with a distal humerus fracture type 13 A2.2 according to AO classification fixed with a new Y-plate (YALP) were compared to the results of double plate fixation for the same type of fracture. With a follow-up of more than 12 months, the objective and subjective clinical elbow criteria as well as the overall function of the upper limb and radiological assessment were collected.
RESULTS
With an average follow up of 24±11 months, 26 patients met the inclusion criteria and received a YALP and 24 patients received double plate. All patients whose fracture had healed except one were pain-free (mean VAS 0.3±0.6). All patients had good subjective results (mean SEV 96%±4). Elbow function was excellent (mean total MEPS 96±4) with normal triceps strength (23/24 patients had a triceps strength graded 5/5 and one patient 4/5) and range of motion (flexion 139±8, extension -7±8 and pronosupination greater than 155 degrees). The operating time was shorter in the YALP group (84 ± 23minutes versus 97 ± 28minutes, p=0.03). The double plate group had more complications; the overall complication rate was significantly higher (p=0.02) in the double 90-degree plate group (12/24, 50%) with four nonunions, four symptomatic ulnar nerves, three hardware removals for pain and one radial nerve injury versus 5/26 complications (19%, p=0.02) in the Y-plate group: one iliac graft for nonunion, 1 plate removal due to functional discomfort, 1 twisted YALP, 1 broke interfragmentary screw and one symptomatic ulnar nerve. DASH, SEV, MEPS scores and flexion-extension range were better in the YALP group.
DISCUSSION
YALP produces satisfactory results in supracondylar fractures of the distal humerus. The results of YALP appear to be better than the results with two 90° plates for the same fracture type with a shorter operative time and easier management of fractures with proximal diaphyseal extension.
LEVEL OF EVIDENCE
III; case control study.