1
|
Kay FU, Madhuranthakam AJ. MR Perfusion Imaging of the Lung. Magn Reson Imaging Clin N Am 2024; 32:111-123. [PMID: 38007274 DOI: 10.1016/j.mric.2023.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2023]
Abstract
Lung perfusion assessment is critical for diagnosing and monitoring a variety of respiratory conditions. MRI perfusion provides a radiation-free technique, making it an ideal choice for longitudinal imaging in younger populations. This review focuses on the techniques and applications of MRI perfusion, including contrast-enhanced (CE) MRI and non-CE methods such as arterial spin labeling (ASL), fourier decomposition (FD), and hyperpolarized 129-Xenon (129-Xe) MRI. ASL leverages endogenous water protons as tracers for a non-invasive measure of lung perfusion, while FD offers simultaneous measurements of lung perfusion and ventilation, enabling the generation of ventilation/perfusion mapsHyperpolarized 129-Xe MRI emerges as a novel tool for assessing regional gas exchange in the lungs. Despite the promise of MRI perfusion techniques, challenges persist, including competition with other imaging techniques and the need for additional validation and standardization. In conditions such as cystic fibrosis and lung cancer, MRI has displayed encouraging results, whereas in diseases like chronic obstructive pulmonary disease, further validation remains necessary. In conclusion, while MRI perfusion techniques hold immense potential for a comprehensive, non-invasive assessment of lung function and perfusion, their broader clinical adoption hinges on technological advancements, collaborative research, and rigorous validation.
Collapse
Affiliation(s)
- Fernando U Kay
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390, USA.
| | - Ananth J Madhuranthakam
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390, USA; Advanced Imaging Research Center, University of Texas Southwestern Medical Center, North Campus 2201 Inwood Road, Dallas, TX 75390-8568, USA
| |
Collapse
|
2
|
Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model. Invest Radiol 2017; 52:547-553. [PMID: 28448310 DOI: 10.1097/rli.0000000000000383] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-tracking technique, and thoracic-abdominal time-resolved 4-dimensional [4D] MRA) were performed after power and manual injection of gadobutrol (0.1 mmol/kg) at 2 mL/s in 12 pigs (6 sets of power and manual injections for each type of CE-MRA). For the quantitative analysis, the signal-to-noise ratio was measured on ascending aorta, descending aorta, brachiocephalic trunk, common carotid artery, and external carotid artery on the 6 sets of head-neck 3D MRA, and on ascending aorta, descending aorta, brachiocephalic trunk, abdominal aorta, celiac trunk, and renal artery on the 6 sets of thoracic-abdominal 3D MRA. Bolus shapes were evaluated on the 6 sets each of test-bolus scans and 4D MRA. For the qualitative analysis, arterial enhancement, superimposition of nontargeted enhancement, and overall image quality were evaluated on 3D MRA. Visibility of bolus transition was assessed on 4D MRA. Intraindividual comparison between power and manual injection was made by paired t test, Wilcoxon rank sum test, and analysis of variance by ranks. RESULTS Signal-to-noise ratio on 3D MRA was statistically higher with power injection than with manual injection (P < 0.001). Bolus shapes (test-bolus, 4D MRA) were represented by a characteristic standard bolus curve (sharp first-pass peak followed by a gentle recirculation peak) in all the 12 scans with power injection, but only in 1 of the 12 scans with manual injection. Standard deviations of time-to-peak enhancement were smaller in power injection than in manual injection. Qualitatively, although both injection methods achieved diagnostic quality on 3D MRA, power injection exhibited significantly higher image quality than manual injection (P = 0.001) due to significantly higher arterial enhancement (P = 0.031) and less superimposition of nontargeted enhancement (P = 0.001). Visibility of bolus transition on 4D MRA was significantly better with power injection than with manual injection (P = 0.031). CONCLUSIONS Compared with manual injection, power injection provides more standardized bolus shapes and higher image quality due to higher arterial enhancement and less superimposition of nontargeted vessels.
Collapse
|
3
|
Sergiacomi G, Taglieri A, Chiaravalloti A, Calabria E, Arduini S, Tosti D, Citraro D, Pezzuto G, Puxeddu E, Simonetti G. Acute COPD exacerbation: 3 T MRI evaluation of pulmonary regional perfusion – Preliminary experience. Respir Med 2014; 108:875-82. [DOI: 10.1016/j.rmed.2014.04.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2013] [Revised: 03/31/2014] [Accepted: 04/03/2014] [Indexed: 11/24/2022]
|
4
|
Characterisation of solitary pulmonary lesions combining visual perfusion and quantitative diffusion MR imaging. Eur Radiol 2013; 24:531-41. [PMID: 24173597 DOI: 10.1007/s00330-013-3053-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2013] [Revised: 09/14/2013] [Accepted: 10/08/2013] [Indexed: 02/06/2023]
Abstract
OBJECTIVE To evaluate the diagnostic accuracy of dynamic contrast-enhanced (DCE) magnetic resonance (MR) and diffusion-weighted imaging (DWI) sequences for defining benignity or malignancy of solitary pulmonary lesions (SPL). METHODS First, 54 consecutive patients with SPL, clinically staged (CT and PET or integrated PET-CT) as N0M0, were included in this prospective study. An additional 3-Tesla MR examination including DCE and DWI was performed 1 day before the surgical procedure. Histopathology of the surgical specimen served as the standard of reference. Subsequently, this functional method of SPL characterisation was validated with a second cohort of 54 patients. RESULTS In the feasibility group, 11 benign and 43 malignant SPL were included. Using the combination of conventional MR sequences with visual interpretation of DCE-MR curves resulted in a sensitivity, specificity and accuracy of 100%, 55% and 91%, respectively. These results can be improved by DWI (with a cut-off value of 1.52 × 10(-3) mm(2)/s for ADChigh) leading to a sensitivity, specificity and accuracy of 98%, 82% and 94%, respectively. In the validation group these results were confirmed. CONCLUSION Visual DCE-MR-based curve interpretation can be used for initial differentiation of benign from malignant SPL, while additional quantitative DWI-based interpretation can further improve the specificity. KEY POINTS • Magnetic resonance imaging is increasingly being used to help differentiate lung lesions. • Solitary pulmonary lesions (SPL) are accurately characterised by combining DCE-MRI and DWI. • Visual DCE-MRI assessment facilitates the diagnostic throughput in patients with SPL. • DWI provides additional information in inconclusive DCE-MRI (type B pattern).
Collapse
|
5
|
Hopkins SR, Wielpütz MO, Kauczor HU. Imaging lung perfusion. J Appl Physiol (1985) 2012; 113:328-39. [PMID: 22604884 PMCID: PMC3404706 DOI: 10.1152/japplphysiol.00320.2012] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2012] [Accepted: 05/14/2012] [Indexed: 11/22/2022] Open
Abstract
From the first measurements of the distribution of pulmonary blood flow using radioactive tracers by West and colleagues (J Clin Invest 40: 1-12, 1961) allowing gravitational differences in pulmonary blood flow to be described, the imaging of pulmonary blood flow has made considerable progress. The researcher employing modern imaging techniques now has the choice of several techniques, including magnetic resonance imaging (MRI), computerized tomography (CT), positron emission tomography (PET), and single photon emission computed tomography (SPECT). These techniques differ in several important ways: the resolution of the measurement, the type of contrast or tag used to image flow, and the amount of ionizing radiation associated with each measurement. In addition, the techniques vary in what is actually measured, whether it is capillary perfusion such as with PET and SPECT, or larger vessel information in addition to capillary perfusion such as with MRI and CT. Combined, these issues affect quantification and interpretation of data as well as the type of experiments possible using different techniques. The goal of this review is to give an overview of the techniques most commonly in use for physiological experiments along with the issues unique to each technique.
Collapse
Affiliation(s)
- Susan R Hopkins
- Departments of Medicine and Radiology, Pulmonary Imaging Laboratory, University of California-San Diego, 9500 Gilman Drive, La Jolla, CA 92093, USA.
| | | | | |
Collapse
|
6
|
Biederer J, Beer M, Hirsch W, Wild J, Fabel M, Puderbach M, Van Beek EJR. MRI of the lung (2/3). Why … when … how? Insights Imaging 2012; 3:355-71. [PMID: 22695944 PMCID: PMC3481084 DOI: 10.1007/s13244-011-0146-8] [Citation(s) in RCA: 145] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2011] [Revised: 11/20/2011] [Accepted: 12/19/2011] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Among the modalities for lung imaging, proton magnetic resonance imaging (MRI) has been the latest to be introduced into clinical practice. Its value to replace X-ray and computed tomography (CT) when radiation exposure or iodinated contrast material is contra-indicated is well acknowledged: i.e. for paediatric patients and pregnant women or for scientific use. One of the reasons why MRI of the lung is still rarely used, except in a few centres, is the lack of consistent protocols customised to clinical needs. METHODS This article makes non-vendor-specific protocol suggestions for general use with state-of-the-art MRI scanners, based on the available literature and a consensus discussion within a panel of experts experienced in lung MRI. RESULTS Various sequences have been successfully tested within scientific or clinical environments. MRI of the lung with appropriate combinations of these sequences comprises morphological and functional imaging aspects in a single examination. It serves in difficult clinical problems encountered in daily routine, such as assessment of the mediastinum and chest wall, and even might challenge molecular imaging techniques in the near future. CONCLUSION This article helps new users to implement appropriate protocols on their own MRI platforms. Main Messages • MRI of the lung can be readily performed on state-of-the-art 1.5-T MRI scanners. • Protocol suggestions based on the available literature facilitate its use for routine • MRI offers solutions for complicated thoracic masses with atelectasis and chest wall invasion. • MRI is an option for paediatrics and science when CT is contra-indicated.
Collapse
Affiliation(s)
- J Biederer
- University Hospital Schleswig-Holstein, Campus Kiel, Department of Diagnostic Radiology, Arnold-Heller-Straße 3, Haus 23, 24105, Kiel, Germany,
| | | | | | | | | | | | | |
Collapse
|
7
|
Puderbach M, Hintze C, Ley S, Eichinger M, Kauczor HU, Biederer J. MR imaging of the chest: A practical approach at 1.5T. Eur J Radiol 2007; 64:345-55. [PMID: 17900843 DOI: 10.1016/j.ejrad.2007.08.009] [Citation(s) in RCA: 146] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2007] [Revised: 07/31/2007] [Accepted: 08/01/2007] [Indexed: 11/25/2022]
Abstract
Magnetic resonance imaging (MRI) is capable of imaging infiltrative lung diseases as well as solid lung pathologies with high sensitivity. The broad use of lung MRI was limited by the long study time as well as its sensitivity to motion and susceptibility artifacts. These disadvantages were overcome by the utilisation of new techniques such as parallel imaging. This article aims to propose a standard MR imaging protocol at 1.5T and presents a spectrum of indications. The standard protocol comprises non-contrast-enhanced sequences. Following a GRE localizer (2D-FLASH), a coronal T2w single-shot half-Fourier TSE (HASTE) sequence with a high sensitivity for infiltrates and a transversal T1w 3D-GRE (VIBE) sequence with a high sensitivity for small lesions are acquired in a single breath hold. Afterwards, a coronal steady-state free precession sequence (TrueFISP) in free breathing is obtained. This sequence has a high sensitivity for central pulmonary embolism. Distinct cardiac dysfunctions as well as an impairment of the breathing mechanism are visible. The last step of the basic protocol is a transversal T2w-STIR (T2-TIRM) in a multi-breath holds technique to visualize enlarged lymph nodes as well as skeletal lesions. The in-room time is approximately 15min. The extended protocol comprises contrast-enhanced sequences (3D-GRE sequence (VIBE) after contrast media; about five additional minutes). Indications are tumorous lesions, unclear (malignant) pleural effusions and inflammatory diseases (vaskulitis). A perfusion analysis can be achieved using a 3D-GRE in shared echo-technique (TREAT) with a high temporal resolution. This protocol can be completed using a MR-angiography (3D-FLASH) with high spatial resolution. The in-room time for the complete protocol is approximately 30min.
Collapse
Affiliation(s)
- M Puderbach
- Department of Radiology (E010), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
| | | | | | | | | | | |
Collapse
|
8
|
Nael K, Saleh R, Nyborg GK, Fonseca CG, Weinmann HJ, Laub G, Finn JP. Pulmonary MR perfusion at 3.0 Tesla using a blood pool contrast agent: Initial results in a swine model. J Magn Reson Imaging 2007; 25:66-72. [PMID: 17154181 DOI: 10.1002/jmri.20799] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To prospectively evaluate the technical feasibility of a highly accelerated pulmonary MR perfusion protocol at 3.0T using a blood pool contrast agent in a swine model. MATERIALS AND METHODS Twelve pigs underwent time-resolved pulmonary MR angiography (MRA) on a 3.0T MR system under anesthesia and controlled mechanical ventilation. After intravenous injection of 0.05 mmol/kg of Gadomer-17 at 4 mL/second, a fast time-resolved MRA sequence with temporal echo-sharing (three segmented k-space) and highly accelerated parallel acquisition was used to acquire 3D data sets with an in-plane resolution of 1 x 1 mm(2) (slice thickness = 6 mm) and temporal resolution of one second. Image quality was evaluated independently by two radiologists, and quantitative analysis of perfusion parameters was performed using pre-released perfusion software. RESULTS All studies were identified by both readers as having diagnostic image quality (range = 2-3, median = 3) and there was excellent interobserver agreement (kappa = 0.89; 95% CI = 0.83, 0.95). A quantitative analysis of perfusion indices was performed, with excellent overall goodness-of-fit (chi(2) value = 1.4, degree of freedom (DF) = 1). Successfully derived perfusion parameters included the time to peak (TTP, 5.1 +/- 0.7 second), mean transit time (MTT, 6.6 +/- 0.9 second), maximal signal intensity (MSI, 1051.2 +/- 718.9 arbitrary units [A.U.]), and maximal upslope of the curve (MUS, 375.9 +/- 263.4 A.U./second). CONCLUSION 3.0T pulmonary MR perfusion using a blood pool contrast agent in a swine model is feasible. The higher available signal-to-noise ratio (SNR) at 3.0T and the high T1 relaxivity of Gadomer-17 effectively support highly accelerated parallel acquisition, and improve the performance of time-resolved pulmonary MRA.
Collapse
Affiliation(s)
- Kambiz Nael
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095-7206, USA.
| | | | | | | | | | | | | |
Collapse
|
9
|
Dehnert C, Risse F, Ley S, Kuder TA, Buhmann R, Puderbach M, Menold E, Mereles D, Kauczor HU, Bärtsch P, Fink C. Magnetic Resonance Imaging of Uneven Pulmonary Perfusion in Hypoxia in Humans. Am J Respir Crit Care Med 2006; 174:1132-8. [PMID: 16946125 DOI: 10.1164/rccm.200606-780oc] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
RATIONALE Inhomogeneous hypoxic pulmonary vasoconstriction causing regional overperfusion and high capillary pressure is postulated for explaining how high pulmonary artery pressure leads to high-altitude pulmonary edema in susceptible (HAPE-S) individuals. OBJECTIVE Because different species of animals also show inhomogeneous hypoxic pulmonary vasoconstriction, we hypothesized that inhomogeneity of lung perfusion in general increases in hypoxia, but is more pronounced in HAPE-S. For best temporal and spatial resolution, regional pulmonary perfusion was assessed by dynamic contrast-enhanced magnetic resonance imaging. METHODS Dynamic contrast-enhanced magnetic resonance imaging and echocardiography were performed during normoxia and after 2 h of hypoxia (Fi(O2) = 0.12) in 11 HAPE-S individuals and 10 control subjects. As a measure for perfusion inhomogeneity, the coefficient of variation for two perfusion parameters (peak signal intensity, time-to-peak) was determined for the whole lung and isogravitational slices. RESULTS There were no differences in perfusion inhomogeneity between the groups in normoxia. In hypoxia, analysis of coefficients of variation indicated a greater inhomogeneity in all subjects, which was more pronounced in HAPE-S compared with control subjects. Discrimination between HAPE-S and control subjects was best in gravity-dependent lung areas. Pulmonary artery pressure during hypoxia increased from 22 +/- 3 to 53 +/- 9 mm Hg in HAPE-S and 24 +/- 4 to 33 +/- 6 mm Hg in control subjects (mean +/- SD; p < 0.001), respectively. CONCLUSION This study shows that hypoxic pulmonary vasoconstriction is inhomogeneous in hypoxia in humans, particularly in HAPE-S individuals where it is accompanied by a greater increase in pulmonary artery pressure compared with control subjects. These findings support the hypothesis of exaggerated and uneven hypoxic pulmonary vasoconstriction in HAPE-S individuals.
Collapse
Affiliation(s)
- Christoph Dehnert
- University Hospital Heidelberg, Internal Medicine VII, Sports Medicine, Im Neuenheimer Feld 410, D-69120 Heidelberg, Germany.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Nael K, Michaely HJ, Kramer U, Lee MH, Goldin J, Laub G, Finn JP. Pulmonary Circulation: Contrast-enhanced 3.0-T MR Angiography—Initial Results. Radiology 2006; 240:858-68. [PMID: 16837670 DOI: 10.1148/radiol.2403051076] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively evaluate the technical feasibility of both high-spatial-resolution and time-resolved contrast material-enhanced magnetic resonance (MR) angiography of the pulmonary circulation at 3.0 T. MATERIALS AND METHODS All examinations were HIPAA compliant. After institutional review board approval and written informed consent, time-resolved and high-spatial-resolution three-dimensional contrast-enhanced MR angiography of the pulmonary circulation was performed with a 3.0-T MR system in 31 adults (13 men, 18 women; age range, 29-87 years old): 22 volunteers and nine patients (two with mediastinal masses, seven with pulmonary arterial hypertension [PAH]). The image quality of pulmonary arterial branches and parenchymal enhancement conspicuity were evaluated independently by two radiologists. The signal-to-noise ratio and quantitative analysis of perfusion parameters was performed. Statistical analysis of data was performed by using Wilcoxon rank sum test and two-sample Student t test, and interobserver variability was tested with kappa coefficient. RESULTS Visualization up to fourth-order pulmonary arterial branches was observed on time-resolved MR angiograms and that up to fifth-order branches was observed on high-spatial-resolution MR angiograms, with diagnostic-quality blood vessel definition and good interobserver agreement. Evaluation of parenchymal enhancement and semiquantitative analysis of perfusion parameters yielded dynamic information in all subjects. Comparative analysis of definition scores for fourth- and fifth-order pulmonary arterial branches, parenchymal enhancement, the time lag between the pulmonary arterial and parenchymal enhancement, and all of the calculated perfusion indices in patients with PAH showed statistically significant differences from volunteers (P < .05). CONCLUSION Three-dimensional contrast-enhanced MR angiography of the pulmonary circulation was feasible at 3.0 T and provided high vascular morphologic detail and dynamic functional information. Clearly detectable abnormalities were present in patients with PAH.
Collapse
Affiliation(s)
- Kambiz Nael
- Department of Radiological Sciences, University of California Los Angeles, 10945 Le Conte Ave, Suite 3371, Los Angeles, CA 90095-7206, USA.
| | | | | | | | | | | | | |
Collapse
|
11
|
Yilmaz E, Akkoclu A, Degirmenci B, Cooper RA, Sengun B, Gulcu A, Osma E, Ucan ES. Accuracy and feasibility of dynamic contrast-enhanced 3D MR imaging in the assessment of lung perfusion: comparison with Tc-99 MAA perfusion scintigraphy. Clin Radiol 2005; 60:905-13. [PMID: 16039926 DOI: 10.1016/j.crad.2005.02.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2004] [Revised: 02/22/2005] [Accepted: 02/22/2005] [Indexed: 11/22/2022]
Abstract
AIM The aim of this study was to correlate findings of perfusion magnetic resonance imaging (MRI) and perfusion scintigraphy in cases where there was a suspicion of abnormal pulmonary vasculature, and to evaluate the usefulness of MRI in the detection of perfusion deficits of the lung. METHODS In all, 17 patients with suspected abnormality of the pulmonary vasculature underwent dynamic contrast-enhanced MRI. T1-weighted 3D fast-field echo pulse sequences were obtained (TR/TE 3.3/1.58 ms; flip angle 30 degrees; slice thickness 12 to 15 mm). The dynamic study was acquired in the coronal plane following administration of 0.1 mmol/kg gadopentetate dimeglumine. A total of 8 to 10 sections repeated 20 to 25 times at intervals of 1s were performed. Perfusion lung scintigraphy was carried out a maximum of 48 h before the MR examination in all cases. Two radiologists, who were blinded to the clinical data and results of other imaging methods, reviewed all coronal sections. MR perfusion images were independently assessed in terms of segmental or lobar perfusion defects in the 85 lobes of the 17 individuals, and the findings were compared with the results of scintigraphy. RESULTS Of the 17 patients, 8 were found to have pulmonary emboli, 2 chronic obstructive pulmonary disease with emphysema, 2 bullous emphysema, 2 Takayasu arteritis and 1 had a hypoplastic pulmonary artery. Pulmonary perfusion was completely normal in 2 cases. In 35 lobes, perfusion defects were detected using both methods, in 4 with MR alone and in 9 only with scintigraphy. There was good agreement between MRI and scintigraphy findings (kappa=0.695). CONCLUSION Pulmonary perfusion MRI is a new alternative to scintigraphy in the evaluation of pulmonary perfusion for various lung disorders. In addition, this technique allows measurement and quantification of pulmonary perfusion abnormalities.
Collapse
Affiliation(s)
- E Yilmaz
- Department of Radiology, Dokuz Eylül University School of Medicine, 35340 Izmir, Turkey.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Nikolaou K, Schoenberg SO, Attenberger U, Scheidler J, Dietrich O, Kuehn B, Rosa F, Huber A, Leuchte H, Baumgartner R, Behr J, Reiser MF. Pulmonary Arterial Hypertension: Diagnosis with Fast Perfusion MR Imaging and High-Spatial-Resolution MR Angiography—Preliminary Experience. Radiology 2005; 236:694-703. [PMID: 15994997 DOI: 10.1148/radiol.2361040502] [Citation(s) in RCA: 110] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To determine prospectively the accuracy of a magnetic resonance (MR) perfusion imaging and MR angiography protocol for differentiation of chronic thromboembolic pulmonary arterial hypertension (CTEPH) and primary pulmonary hypertension (PPH) by using parallel acquisition techniques. MATERIALS AND METHODS The study was approved by the institution's internal review board, and all patients gave written consent prior to participation. A total of 29 patients (16 women; mean age, 54 years +/- 17 [+/- standard deviation]; 13 men; mean age, 57 years +/- 15) with known pulmonary hypertension were examined with a 1.5-T MR imager. MR perfusion imaging (temporal resolution, 1.1 seconds per phase) and MR angiography (matrix, 512; voxel size, 1.0 x 0.7 x 1.6 mm) were performed with parallel acquisition techniques. Dynamic perfusion images and reformatted three-dimensional MR angiograms were analyzed for occlusive and nonocclusive changes of the pulmonary arteries, including perfusion defects, caliber irregularities, and intravascular thrombi. MR perfusion imaging results were compared with those of radionuclide perfusion scintigraphy, and MR angiography results were compared with those of digital subtraction angiography (DSA) and/or contrast material-enhanced multi-detector row computed tomography (CT). Sensitivity, specificity, and diagnostic accuracy of MR perfusion imaging and MR angiography were calculated. Receiver operator characteristic analyses were performed to compare the diagnostic value of MR angiography, MR perfusion imaging, and both modalities combined. For MR angiography and MR perfusion imaging, kappa values were used to assess interobserver agreement. RESULTS A correct diagnosis was made in 26 (90%) of 29 patients by using this comprehensive MR imaging protocol. Results of MR perfusion imaging demonstrated 79% agreement (ie, identical diagnosis on a per-patient basis) with those of perfusion scintigraphy, and results of MR angiography demonstrated 86% agreement with those of DSA and/or CT angiography. Interobserver agreement was good for both MR perfusion imaging and MR angiography (kappa = 0.63 and 0.70, respectively). CONCLUSION The combination of fast MR perfusion imaging and high-spatial-resolution MR angiography with parallel acquisition techniques enables the differentiation of PPH from CTEPH with high accuracy.
Collapse
Affiliation(s)
- Konstantin Nikolaou
- Department of Clinical Radiology, Nuclear Medicine, and Internal Medicine I, Ludwig-Maximilians-University Munich, Klinikum Grosshadern, Marchioninistr 15, 81377 Munich, Germany.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Fink C, Ley S, Risse F, Eichinger M, Zaporozhan J, Buhmann R, Puderbach M, Plathow C, Kauczor HU. Effect of Inspiratory and Expiratory Breathhold on Pulmonary Perfusion. Invest Radiol 2005; 40:72-9. [PMID: 15654250 DOI: 10.1097/01.rli.0000149252.42679.78] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
RATIONALE AND OBJECTIVES The effect of breathholding on pulmonary perfusion remains largely unknown. The aim of this study was to assess the effect of inspiratory and expiratory breathhold on pulmonary perfusion using quantitative pulmonary perfusion magnetic resonance imaging (MRI). METHODS AND RESULTS Nine healthy volunteers (median age, 28 years; range, 20-45 years) were examined with contrast-enhanced time-resolved 3-dimensional pulmonary perfusion MRI (FLASH 3D, TR/TE: 1.9/0.8 ms; flip angle: 40 degrees; GRAPPA) during end-inspiratory and expiratory breathholds. The perfusion parameters pulmonary blood flow (PBF), pulmonary blood volume (PBV), and mean transit time (MTT) were calculated using the indicator dilution theory. As a reference method, end-inspiratory and expiratory phase-contrast (PC) MRI of the pulmonary arterial blood flow (PABF) was performed. RESULTS There was a statistically significant increase of the PBF (delta = 182 mL/100 mL/min), PBV (delta = 12 mL/100 mL), and PABF (delta = 0.5 L/min) between inspiratory and expiratory breathhold measurements (P < 0.0001). Also, the MTT was significantly shorter (delta = -0.5 sec) at expiratory breathhold (P = 0.03). Inspiratory PBF and PBV showed a moderate correlation (r = 0.72 and 0.61, P < or = 0.008) with inspiratory PABF. CONCLUSION Pulmonary perfusion during breathhold depends on the inspiratory level. Higher perfusion is observed at expiratory breathhold.
Collapse
Affiliation(s)
- Christian Fink
- Department of Radiology, Deutsches Krebsforschungszentrum, Heidelberg, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Nikolaou K, Schoenberg SO, Brix G, Goldman JP, Attenberger U, Kuehn B, Dietrich O, Reiser MF. Quantification of Pulmonary Blood Flow and Volume in Healthy Volunteers by Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Parallel Imaging Technique. Invest Radiol 2004; 39:537-45. [PMID: 15308936 DOI: 10.1097/01.rli.0000133813.22873.47] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
RATIONALE AND OBJECTIVES We sought to optimize the dosage of a paramagnetic contrast medium (CM) for the quantification of pulmonary blood flow and volume by contrast-enhanced dynamic magnetic resonance imaging (MRI) using a parallel imaging technique and to prove the feasibility of the approach in healthy volunteers. METHODS In a phantom study, the dependency of signal increase on different concentrations of the CM gadodiamide was evaluated by means of an ultra-fast MRI sequence with a generalized autocalibrating partially parallel acquisition technique (acceleration factor = 2). Using the same sequence, measurements were performed in a healthy volunteer after administration of different CM dosages for contrast dosage optimization in vivo. Finally, perfusion measurements were performed in 16 healthy volunteers after the administration of the optimal CM dose. Signal-time curves were evaluated from the pulmonary artery and from predefined regions of the lung. Pulmonary regional blood volume (RBV) and flow (RBF) were estimated using an open 1-compartment model. RESULTS Phantom studies yielded a linear signal increase up to a concentration of 5.0 mmol/L gadodiamide. Results of contrast dosage optimization in vivo showed that the maximum CM dose providing a linear relationship between signal increase and CM concentration in the pulmonary artery of a healthy volunteer was approximately 0.05 mmol/kg-bw. Quantification of pulmonary blood volume and flow was reproducible in healthy volunteers, yielding mean values for the upper lung zones of 7.1 +/- 2.3 mL/100 mL for RBV and 197 +/- 97 mL/min/100 mL for RBF and for lower lung zones, 12.5 +/- 3.9 mL/100 mL for RBV and 382 +/- 111 mL/min/100 mL for RBF. CONCLUSIONS If an adequate amount of gadodiamide and fast MR sequences are used, quantification of pulmonary blood flow and volume is feasible.
Collapse
|
15
|
Fink C, Puderbach M, Ley S, Plathow C, Bock M, Zuna I, Kauczor HU. Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging: intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels. Invest Radiol 2004; 39:143-8. [PMID: 15076006 DOI: 10.1097/01.rli.0000101482.79137.f4] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
RATIONALE AND OBJECTIVES To compare 1.0 M gadobutrol and 0.5 M Gd-DTPA for contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging (3D MRI). MATERIALS AND METHODS Ten healthy volunteers (3 females; 7 males; median age, 27 years; age range, 18-31 years) were examined with contrast-enhanced dynamic 3D MRI with parallel acquisition technique (FLASH 3D; reconstruction algorithm: generalized autocalibrating partially parallel acquisitions; acceleration factor: 2; TE/TR/alpha: 0.8/1.9 milliseconds/40 degrees; FOV: 500 x 375 mm; matrix: 256 x 86; slab thickness: 180 mm; 36 partitions; voxel size: 4.4 x 2 x 5 mm; TA: 1.48 seconds). Twenty-five consecutive data sets were acquired after intravenous injection of 0.025, 0.05, and 0.1 mmol/kg body weight of gadobutrol and Gd-DTPA. Quantitative measurements of peak signal-to-noise ratios (SNR) of both lungs were performed independently by 3 readers. Bolus transit times through the lungs were assessed from signal intensity time curves. RESULTS The peak SNR in the lungs was comparable between gadobutrol and Gd-DTPA at all dose levels (15.7 vs. 15.5 at 0.1 mmol/kg bw; 12.9 vs. 12.5 at 0.05 mmol/kg bw; 7.6 vs. 8.9 at 0.025 mmol/kg bw). A dose of 0.1 mmol/kg achieved the highest peak SNR compared with all other dose levels (P < 0.05). A higher peak SNR was observed in gravity dependent lung (P < 0.05). Despite different injection volumes, transit times of the contrast bolus did not differ between both agents. CONCLUSION Higher concentrated gadolinium chelates offer no advantage over standard 0.5 M Gd-DTPA for contrast-enhanced 3D MRI of lung perfusion.
Collapse
Affiliation(s)
- Christian Fink
- Department of Radiology, Deutsches Krebsforschungszentrum (DKFZ), Innovative Krebsdiagnostik und Therapie, Heidelberg, Germany.
| | | | | | | | | | | | | |
Collapse
|
16
|
Fink C, Puderbach M, Bock M, Lodemann KP, Zuna I, Schmähl A, Delorme S, Kauczor HU. Regional lung perfusion: assessment with partially parallel three-dimensional MR imaging. Radiology 2004; 231:175-84. [PMID: 15068947 DOI: 10.1148/radiol.2311030193] [Citation(s) in RCA: 85] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate partially parallel three-dimensional (3D) magnetic resonance (MR) imaging for assessment of regional lung perfusion in healthy volunteers and patients suspected of having lung cancer or metastasis. MATERIALS AND METHODS Seven healthy volunteers and 20 patients suspected of having lung cancer or metastasis were examined with 3D gradient-echo MR imaging with partially parallel image acquisitions (fast low-angle shot 3D imaging; repetition time msec/echo time msec, 1.9/0.8; flip angle, 40 degrees; acceleration factor, two; number of reference k-space lines for calibration, 24; field of view, 500 x 440 mm; matrix, 256 x 123; slab thickness, 160 mm; number of partitions, 32; voxel size, 3.6 x 2.0 x 5.0 mm(3); acquisition time, 1.5 seconds) after administration of 0.1 mmol/kg of gadobenate dimeglumine. In volunteers, 3D MR perfusion data sets were assessed for topographic and temporal distribution of regional lung perfusion. Sensitivity, specificity, accuracy, and positive and negative predictive values for perfusion MR imaging for detecting perfusion abnormalities in patients were calculated, with conventional radionuclide perfusion scintigraphy as the standard of reference. Interobserver and intermodality agreement was determined by using kappa statistics. RESULTS Topographic analysis of lung perfusion in volunteers revealed a significantly higher signal-to-noise ratio (SNR) of up to 327% in gravity-dependent lung areas. Temporal analysis similarly revealed much shorter lag time to peak enhancement in gravity-dependent lung areas. In patients, perfusion MR imaging achieved high sensitivity (88%-94%), specificity (100%), and accuracy (90%-95%) for detection of perfusion abnormalities. Interobserver agreement (kappa = 0.86) was very good and intermodality agreement (kappa = 0.69-0.83) was good to very good for detection of perfusion defects. A significant difference (P <.0001) in SNR was observed between normally perfused lung (14 +/- 7 [SD]) and perfusion defects (7 +/- 4) in patients. CONCLUSION Partially parallel MR imaging with high spatial and temporal resolution allows assessment of regional lung perfusion and has high diagnostic accuracy for detecting perfusion abnormalities.
Collapse
Affiliation(s)
- Christian Fink
- Department of Radiology, Deutsches Krebsforschungszentrum, Innovative Krebsdiagnostik und Therapie, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Sonnet S, Buitrago-Téllez CH, Schulte AC, Bongartz G, Bremerich J. Dose optimization for dynamic time-resolved contrast-enhanced 3D MR angiography of pulmonary circulation. AJR Am J Roentgenol 2004; 181:1499-503. [PMID: 14627563 DOI: 10.2214/ajr.181.6.1811499] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The aim of this study was to optimize contrast media dose for assessment of pulmonary circulation with dynamic time-resolved contrast-enhanced 3D MR angiography. SUBJECTS AND METHODS. Twenty healthy volunteers (20-38 years old; mean [+/- SD], 27.2 +/- 4.5 years) were examined prospectively using turbo fast low-angle shot MR angiography (TR/TE, 2.4/1.04). Ten consecutive coronal 3D slabs with a frame rate of 3.2-sec duration were acquired during injection of contrast media at a rate of 4 mL/sec. Signal intensities were measured in various vessels and pulmonary parenchyma. Maximum signal-intensity enhancement (DeltaSI(max)) and time to peak enhancement were calculated. Depiction of pulmonary vessels and pulmonary parenchyma was scored according to an image quality score. RESULTS Central pulmonary arteries were well visualized at all tested doses. Segmental arteries, however, were blurry with 0.025 or 0.05 mmol/kg; image quality was improved at 0.1 mmol/kg of gadoterate meglumine (p < 0.05). Image quality did not further improve at 0.2 mmol/kg (p = not significant). Values for DeltaSI(max) in the pulmonary trunk were 38.9 +/- 9.7, 64.1 +/- 9.1, 79.7 +/- 12.2, and 96 +/- 6.0 at 0.025, 0.5, 0.1, and 0.2 mmol/kg of gadoterate meglumine, respectively. Pulmonary parenchyma showed almost no enhancement at 0.025 and 0.5 mmol/kg of gadoterate meglumine (DeltaSI(max) = 1.6 +/- 1.1 and 1.6 +/- 1.2, respectively), but better visualization was shown with 0.1 and 0.2 mmol/kg of gadoterate meglumine (DeltaSI(max) = 2.9 +/- 0.8 and 6.7 +/- 2.1, respectively). Time from peak enhancement in pulmonary arteries to peak enhancement in veins was independent of dose. CONCLUSION A dose of 0.1 mmol/kg of gadolinium chelate allows depiction of pulmonary arteries and qualitative assessment of pulmonary parenchyma. Thus, 0.1 mmol/kg can be recommended for dynamic contrast-enhanced 3D MR angiography.
Collapse
Affiliation(s)
- Stefan Sonnet
- Department of Radiology, University Hospitals Basel, Petersgraben 4, CH-4053 Basel, Switzerland
| | | | | | | | | |
Collapse
|
18
|
van Beek EJR, Wild JM, Fink C, Moody AR, Kauczor HU, Oudkerk M. MRI for the diagnosis of pulmonary embolism. J Magn Reson Imaging 2003; 18:627-40. [PMID: 14635147 DOI: 10.1002/jmri.10421] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Pulmonary embolism (PE) is one of the most frequently encountered clinical emergencies. The diagnosis often involves multiple diagnostic tests, which need to be carried out rapidly to assist in the safe management of the patient. Recent strides in computed tomography (CT) have made big improvements in patient management and efficiency of diagnostic imaging. This review article describes the developments in magnetic resonance (MR) techniques for the diagnosis of acute PE. Techniques include MR angiography (MRA) and thrombus imaging for direct clot visualization, perfusion MR, and combined perfusion-ventilation MR. As will be demonstrated, some of these techniques are now entering the clinical arena, and it is anticipated that MR imaging (MRI) will have an increasing role in the initial diagnosis and follow-up of patients with acute PE.
Collapse
|
19
|
Fink C, Bock M, Puderbach M, Schmähl A, Delorme S. Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion--initial results. Invest Radiol 2003; 38:482-8. [PMID: 12874514 DOI: 10.1097/01.rli.0000067490.97837.82] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
RATIONALE Contrast-enhanced magnetic resonance imaging (MRI) of lung perfusion requires a high spatial and temporal resolution. Partially parallel MRI offers an improved spatial and temporal resolution. OBJECTIVE To assess the feasibility of partially parallel MRI for the assessment of lung perfusion. METHODS Two healthy volunteers and 14 patients were examined with a contrast-enhanced 3D gradient-echo pulse sequence with partially parallel image acquisitions (TE/TR/alpha: 0.8/1.9 milliseconds/40 degrees; voxel size 3.6 x 2.0 x 5.0 mm3, TA: 1.5 seconds). The image analysis included an analysis of the signal-to-noise ratio in the lungs in areas with normal and impaired perfusion. 3D MR perfusion image data were analyzed for perfusion defects and compared with radionuclide perfusion scans, which were available for 10 of 14 patients. RESULTS The analysis of the 3D perfusion-weighted data allowed a clear differentiation of perfusion abnormalities: MRI showed normal lung perfusion in 9 of 16 cases, whereas perfusion abnormalities were observed in 7 cases. When compared with the radionuclide perfusion scans, a good intermodality agreement was shown (kappa = 0.74). When compared with normally perfused lung a significantly lower signal to noise ratio was observed in hypoperfused lung (7 versus 17; P = 0.02). CONCLUSION Partially parallel MRI might be used for the assessment of lung perfusion. Future studies are required to further evaluate the diagnostic impact of this technique.
Collapse
Affiliation(s)
- Christian Fink
- Deutsches Krebsforschungszentrum, Innovative Krebsdiagnostik und Therapie, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
| | | | | | | | | |
Collapse
|
20
|
Uematsu H, Ohno Y, Hatabu H. Recent advances in magnetic resonance perfusion imaging of the lung. Top Magn Reson Imaging 2003; 14:245-51. [PMID: 12973132 DOI: 10.1097/00002142-200306000-00005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Magnetic resonance imaging has been relatively underused for clinical application in the lung; however, developments in magnetic resonance perfusion imaging using contrast agents and spin labeling techniques have shown significant potential for clinical application in lung perfusion. This article reviews the recent publications on magnetic resonance pulmonary perfusion.
Collapse
Affiliation(s)
- Hidemasa Uematsu
- Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, PA, USA.
| | | | | |
Collapse
|
21
|
Iwasawa T, Saito K, Ogawa N, Ishiwa N, Kurihara H. Prediction of postoperative pulmonary function using perfusion magnetic resonance imaging of the lung. J Magn Reson Imaging 2002; 15:685-92. [PMID: 12112519 DOI: 10.1002/jmri.10121] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To assess semiquantitatively the regional distribution of lung perfusion using magnetic resonance (MR) perfusion imaging. MATERIALS AND METHODS Subjects were 20 consecutive patients with bronchogenic carcinoma, who underwent MR imaging (MRI) and radionuclide (RN) perfusion scans for preoperative evaluation. Three-dimensional (3D) images of whole lungs were obtained before and 7 seconds after bolus injection of contrast material (5 ml of Gd-DTPA). Subtraction images were constructed from these dynamic images. Lung areas enhanced with the contrast material were measured and multiplied by changes in signal intensity, summed for the whole lung, and the right-to-left lung ratios were calculated. The predicted postoperative forced expiratory volume in 1 second (FEV1) was estimated using MR and RN perfusion ratios. RESULTS The correlation between perfusion ratios derived from the MR and RN studies was excellent (r = 0.92). Sixteen of 20 patients underwent surgery, and 12 patients had postoperative pulmonary function tests. The predicted FEV1 derived from the MR perfusion ratio correlated well with the postoperative FEV1 in the 12 patients (r = 0.68). CONCLUSION Perfusion MRI is suitable for semiquantitative evaluation of regional pulmonary perfusion.
Collapse
Affiliation(s)
- Tae Iwasawa
- Department of Radiology, Kanagawa Cardiovascular and Respiratory Center, Tomiokahigashi, Kanazawa-ku, Yokohama, Japan.
| | | | | | | | | |
Collapse
|