1
|
Sun B, Liu J, Li S, Lovell JF, Zhang Y. Imaging of Gastrointestinal Tract Ailments. J Imaging 2023; 9:115. [PMID: 37367463 DOI: 10.3390/jimaging9060115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/20/2023] [Accepted: 05/25/2023] [Indexed: 06/28/2023] Open
Abstract
Gastrointestinal (GI) disorders comprise a diverse range of conditions that can significantly reduce the quality of life and can even be life-threatening in serious cases. The development of accurate and rapid detection approaches is of essential importance for early diagnosis and timely management of GI diseases. This review mainly focuses on the imaging of several representative gastrointestinal ailments, such as inflammatory bowel disease, tumors, appendicitis, Meckel's diverticulum, and others. Various imaging modalities commonly used for the gastrointestinal tract, including magnetic resonance imaging (MRI), positron emission tomography (PET) and single photon emission computed tomography (SPECT), and photoacoustic tomography (PAT) and multimodal imaging with mode overlap are summarized. These achievements in single and multimodal imaging provide useful guidance for improved diagnosis, staging, and treatment of the corresponding gastrointestinal diseases. The review evaluates the strengths and weaknesses of different imaging techniques and summarizes the development of imaging techniques used for diagnosing gastrointestinal ailments.
Collapse
Affiliation(s)
- Boyang Sun
- Key Laboratory of Systems Bioengineering, School of Chemical Engineering and Technology, Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin 300350, China
| | - Jingang Liu
- Key Laboratory of Systems Bioengineering, School of Chemical Engineering and Technology, Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin 300350, China
| | - Silu Li
- Key Laboratory of Systems Bioengineering, School of Chemical Engineering and Technology, Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin 300350, China
| | - Jonathan F Lovell
- Department of Biomedical Engineering, The State University of New York at Buffalo, Buffalo, NY 14260, USA
| | - Yumiao Zhang
- Key Laboratory of Systems Bioengineering, School of Chemical Engineering and Technology, Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin 300350, China
| |
Collapse
|
2
|
Influence of oral contrast type and volume on patient experience and quality of luminal distension at MR Enterography in Crohn's disease: an observational study of patients recruited to the METRIC trial. Eur Radiol 2022; 32:5075-5085. [PMID: 35243523 PMCID: PMC9279188 DOI: 10.1007/s00330-022-08614-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 01/20/2022] [Accepted: 01/24/2022] [Indexed: 12/03/2022]
Abstract
Objectives To compare the distention quality and patient experience of oral mannitol and polyethylene glycol (PEG) for MRE. Methods This study is a retrospective, observational study of a subset of patients enrolled in a multicentre, prospective trial evaluating the diagnostic accuracy of MRE for small bowel Crohn’s. Overall and segmental MRE small bowel distention, from 105 patients (64 F, mean age 37) was scored from 0 = poor to 4 = excellent by two experienced observers (68 [65%] mannitol and 37 [35%] PEG). Additionally, 130 patients (77 F, mean age 34) completed a questionnaire rating tolerability of various symptoms immediately and 2 days after MRE (85 [65%] receiving mannitol 45 [35%] receiving PEG). Distension was compared between agents and between those ingesting ≤ 1 L or > 1 L of mannitol using the test of proportions. Tolerability grades were collapsed into “very tolerable,” “moderately tolerable,” and “not tolerable.” Results Per patient distension quality was similar between agents (“excellent” or “good” in 54% [37/68] versus 46% [17/37]) with mannitol and PEG respectively. Jejunal distension was significantly better with mannitol compared to PEG (40% [27/68] versus 14% [5/37] rated as excellent or good respectively). There was no significant difference according to the volume of mannitol ingested. Symptom tolerability was comparable between agents, although fullness following MRE was graded as “very tolerable” in 27% (12/45) of patients ingesting PEG, verses 44% (37/84) ingesting mannitol, difference 17% (95% CI 0.6 to 34%). Conclusion Mannitol-based solutions and PEG generally achieve comparable distension quality and side effect profiles, although jejunal distension is better quality with mannitol. Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol. Key Points • Mannitol-based and PEG-based oral preparation agents generally achieve comparable distension quality for MRE with the exception of the jejunum which is better distended with mannitol. • Mannitol-based and PEG-based oral preparation agents used for MRE have similar side effect profiles. • Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol. Supplementary Information The online version contains supplementary material available at 10.1007/s00330-022-08614-9.
Collapse
|
3
|
Taylor SA, Mallett S, Bhatnagar G, Morris S, Quinn L, Tomini F, Miles A, Baldwin-Cleland R, Bloom S, Gupta A, Hamlin PJ, Hart AL, Higginson A, Jacobs I, McCartney S, Murray CD, Plumb AA, Pollok RC, Rodriguez-Justo M, Shabir Z, Slater A, Tolan D, Travis S, Windsor A, Wylie P, Zealley I, Halligan S. Magnetic resonance enterography compared with ultrasonography in newly diagnosed and relapsing Crohn's disease patients: the METRIC diagnostic accuracy study. Health Technol Assess 2020; 23:1-162. [PMID: 31432777 DOI: 10.3310/hta23420] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Magnetic resonance enterography and enteric ultrasonography are used to image Crohn's disease patients. Their diagnostic accuracy for presence, extent and activity of enteric Crohn's disease was compared. OBJECTIVE To compare diagnostic accuracy, observer variability, acceptability, diagnostic impact and cost-effectiveness of magnetic resonance enterography and ultrasonography in newly diagnosed or relapsing Crohn's disease. DESIGN Prospective multicentre cohort study. SETTING Eight NHS hospitals. PARTICIPANTS Consecutive participants aged ≥ 16 years, newly diagnosed with Crohn's disease or with established Crohn's disease and suspected relapse. INTERVENTIONS Magnetic resonance enterography and ultrasonography. MAIN OUTCOME MEASURES The primary outcome was per-participant sensitivity difference between magnetic resonance enterography and ultrasonography for small bowel Crohn's disease extent. Secondary outcomes included sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease extent, and sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease presence; identification of active disease; interobserver variation; participant acceptability; diagnostic impact; and cost-effectiveness. RESULTS Out of the 518 participants assessed, 335 entered the trial, with 51 excluded, giving a final cohort of 284 (133 and 151 in new diagnosis and suspected relapse cohorts, respectively). Across the whole cohort, for small bowel Crohn's disease extent, magnetic resonance enterography sensitivity [80%, 95% confidence interval (CI) 72% to 86%] was significantly greater than ultrasonography sensitivity (70%, 95% CI 62% to 78%), with a 10% difference (95% CI 1% to 18%; p = 0.027). For small bowel Crohn's disease extent, magnetic resonance enterography specificity (95%, 95% CI 85% to 98%) was significantly greater than ultrasonography specificity (81%, 95% CI 64% to 91%), with a 14% difference (95% CI 1% to 27%). For small bowel Crohn's disease presence, magnetic resonance enterography sensitivity (97%, 95% CI 91% to 99%) was significantly greater than ultrasonography sensitivity (92%, 95% CI 84% to 96%), with a 5% difference (95% CI 1% to 9%). For small bowel Crohn's disease presence, magnetic resonance enterography specificity was 96% (95% CI 86% to 99%) and ultrasonography specificity was 84% (95% CI 65% to 94%), with a 12% difference (95% CI 0% to 25%). Test sensitivities for small bowel Crohn's disease presence and extent were similar in the two cohorts. For colonic Crohn's disease presence in newly diagnosed participants, ultrasonography sensitivity (67%, 95% CI 49% to 81%) was significantly greater than magnetic resonance enterography sensitivity (47%, 95% CI 31% to 64%), with a 20% difference (95% CI 1% to 39%). For active small bowel Crohn's disease, magnetic resonance enterography sensitivity (96%, 95% CI 92% to 99%) was significantly greater than ultrasonography sensitivity (90%, 95% CI 82% to 95%), with a 6% difference (95% CI 2% to 11%). There was some disagreement between readers for both tests. A total of 88% of participants rated magnetic resonance enterography as very or fairly acceptable, which is significantly lower than the percentage (99%) of participants who did so for ultrasonography. Therapeutic decisions based on magnetic resonance enterography alone and ultrasonography alone agreed with the final decision in 122 out of 158 (77%) cases and 124 out of 158 (78%) cases, respectively. There were no differences in costs or quality-adjusted life-years between tests. LIMITATIONS Magnetic resonance enterography and ultrasonography scans were interpreted by practitioners blinded to clinical data (but not participant cohort), which does not reflect use in clinical practice. CONCLUSIONS Magnetic resonance enterography has higher accuracy for detecting the presence, extent and activity of small bowel Crohn's disease than ultrasonography does. Both tests have variable interobserver agreement and are broadly acceptable to participants, although ultrasonography produces less participant burden. Diagnostic impact and cost-effectiveness are similar. Recommendations for future work include investigation of the comparative utility of magnetic resonance enterography and ultrasonography for treatment response assessment and investigation of non-specific abdominal symptoms to confirm or refute Crohn's disease. TRIAL REGISTRATION Current Controlled Trials ISRCTN03982913. FUNDING This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 23, No. 42. See the NIHR Journals Library website for further project information.
Collapse
Affiliation(s)
- Stuart A Taylor
- Centre for Medical Imaging, University College London, London, UK
| | - Sue Mallett
- Institute of Applied Health Research, National Institute for Health Research Birmingham Biomedical Research Centre, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK
| | | | - Stephen Morris
- Applied Health Research, University College London, London, UK
| | - Laura Quinn
- Institute of Applied Health Research, National Institute for Health Research Birmingham Biomedical Research Centre, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK
| | - Florian Tomini
- Applied Health Research, University College London, London, UK
| | - Anne Miles
- Department of Psychological Sciences, Birkbeck, University of London, London, UK
| | - Rachel Baldwin-Cleland
- Intestinal Imaging Centre, St Mark's Hospital, London North West University Healthcare NHS Trust, Harrow, UK
| | - Stuart Bloom
- Department of Gastroenterology, University College Hospital, London, UK
| | - Arun Gupta
- Intestinal Imaging Centre, St Mark's Hospital, London North West University Healthcare NHS Trust, Harrow, UK
| | - Peter John Hamlin
- Department of Gastroenterology, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Ailsa L Hart
- Inflammatory Bowel Disease Unit, St Mark's Hospital, London North West University Healthcare NHS Trust, Harrow, UK
| | - Antony Higginson
- Department of Radiology, Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | - Ilan Jacobs
- Independent patient representative, c/o Centre for Medical Imaging, University College London, London, UK
| | - Sara McCartney
- Department of Gastroenterology, University College Hospital, London, UK
| | - Charles D Murray
- Department of Gastroenterology and Endoscopy, Royal Free London NHS Foundation Trust, London, UK
| | - Andrew Ao Plumb
- Centre for Medical Imaging, University College London, London, UK
| | - Richard C Pollok
- Department of Gastroenterology, St George's Hospital, London, UK
| | | | - Zainib Shabir
- Comprehensive Clinical Trials Unit, Institute of Clinical Trials and Methodology, University College London, London, UK
| | - Andrew Slater
- Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Damian Tolan
- Department of Radiology, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Simon Travis
- Translational Gastroenterology Unit, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | | | - Peter Wylie
- Department of Radiology, Royal Free London NHS Foundation Trust, London, UK
| | - Ian Zealley
- Department of Radiology, Ninewells Hospital, Dundee, UK
| | - Steve Halligan
- Centre for Medical Imaging, University College London, London, UK
| |
Collapse
|
4
|
Schöllnast H. Radiologische Charakterisierung chronisch-entzündlicher Darmerkrankungen. Radiologe 2018; 58:312-319. [DOI: 10.1007/s00117-018-0372-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
5
|
Schmidt SA, Baumann JA, Stanescu-Siegmund N, Froehlich E, Brambs HJ, Juchems MS. Oral distension methods for small bowel MRI: comparison of different agents to optimize bowel distension. Acta Radiol 2016; 57:1460-1467. [PMID: 26868172 DOI: 10.1177/0284185116631183] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Background Different methods for bowel distension prior to magnetic resonance imaging (MRI) examinations were described in recent years. Purpose To compare orally administered psyllium or locust bean gum / mannitol (LBM) with tylose administered through a duodenal catheter for bowel distension in patients undergoing MRI examination of the small bowel. Material and Methods Three different methods of bowel distension prior to MRI were compared: tylose applied through a duodenal catheter and orally administered psyllium and LBM in three groups with 15 patients each. Datasets were blinded and reviewed independently by two experienced radiologists, who assessed the diagnostic value and the maximum luminal diameter. Results Tylose was superior to psyllium and LBM in the examination of the duodenum and proximal jejunum. LBM was superior to the other methods for distension of the ileum and terminal ileum. The greatest luminal diameter of the duodenum was achieved after tylose and distension of the terminal ileum was the best in patients receiving LBM. The psyllium group was inferior to the other two groups in all segments. Conclusion By using LBM as an oral method of bowel distension, many patients can avoid the unpleasant placement of a duodenal catheter without compromising the diagnostic value of the examination.
Collapse
Affiliation(s)
- Stefan A Schmidt
- 1 Department of Diagnostic and Interventional Radiology, University Hospital of Ulm, Ulm, Germany
| | - Julia A Baumann
- 1 Department of Diagnostic and Interventional Radiology, University Hospital of Ulm, Ulm, Germany
| | - Nora Stanescu-Siegmund
- 1 Department of Diagnostic and Interventional Radiology, University Hospital of Ulm, Ulm, Germany
| | - Eckhart Froehlich
- 2 Department of Internal Medicine, Karl-Olga Hospital, Stuttgart, Germany
| | - Hans-Juergen Brambs
- 1 Department of Diagnostic and Interventional Radiology, University Hospital of Ulm, Ulm, Germany
| | - Markus S Juchems
- 3 Department of Diagnostic and Interventional Radiology, Konstanz Hospital, Konstanz, Germany
| |
Collapse
|
6
|
Gupta MK, Khatri G, Bailey A, Pinho DF, Costa D, Pedrosa I. Endoluminal contrast for abdomen and pelvis magnetic resonance imaging. Abdom Radiol (NY) 2016; 41:1378-98. [PMID: 26907710 DOI: 10.1007/s00261-016-0668-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Magnetic resonance (MR) imaging of the abdomen and pelvis can be limited for assessment of different conditions when imaging inadequately distended hollow organs. Endoluminal contrast agents may provide improved anatomic definition and detection of subtle pathology in such scenarios. The available routes of administration for endoluminal contrast agents include oral, endorectal, endovaginal, intravesicular, and through non-physiologic accesses. Appropriate use of endoluminal contrast agents requires a thorough understanding of the clinical indications, available contrast agents, patient preparation, and interaction of the contrast agent with the desired MR imaging protocol. For example, biphasic oral enteric contrast agents are preferred in MR enterography as their signal properties on T1- and T2-weighted imaging allow for evaluation of both intraluminal and bowel wall pathology. In specific situations such as with MR enterography, MR defecography, and accurate local staging of certain pelvic tumors, the use of an endoluminal contrast agent is imperative in providing adequate diagnostic imaging. In other clinical scenarios, the use of an endoluminal contrast agent may serve as an indispensable problem-solving tool.
Collapse
Affiliation(s)
- Mohit K Gupta
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX, 75390-9085, USA
| | - Gaurav Khatri
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX, 75390-9085, USA
| | - April Bailey
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX, 75390-9085, USA
| | - Daniella F Pinho
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX, 75390-9085, USA
| | - Daniel Costa
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX, 75390-9085, USA
| | - Ivan Pedrosa
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX, 75390-9085, USA.
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, USA.
| |
Collapse
|
7
|
Evaluation of Patient Tolerance and Small-Bowel Distention With a New Small-Bowel Distending Agent for Enterography. AJR Am J Roentgenol 2016; 206:994-1002. [DOI: 10.2214/ajr.15.15260] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
8
|
Masselli G, Di Tola M, Casciani E, Polettini E, Laghi F, Monti R, Bernieri MG, Gualdi G. Diagnosis of Small-Bowel Diseases: Prospective Comparison of Multi-Detector Row CT Enterography with MR Enterography. Radiology 2015; 279:420-31. [PMID: 26599801 DOI: 10.1148/radiol.2015150263] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE To prospectively compare the accuracies of computed tomographic (CT) enterography and magnetic resonance (MR) enterography for the detection and characterization of small-bowel diseases. MATERIALS AND METHODS The institutional review board approved the study protocol, and informed consent was obtained from all participants. From June 2009 to July 2013, 150 consecutive patients (81 men and 69 women; mean age, 38.8 years; range, 18-74 years), who were suspected of having a small-bowel disease on the basis of clinical findings and whose previous upper and lower gastrointestinal endoscopy findings were normal, underwent CT and MR enterography. Two independent readers reviewed CT and MR enterographic images for the presence of small-bowel diseases, for differentiating between inflammatory and noninflammatory diseases, and for extraenteric complications. The histopathologic findings of surgical (n = 23) and endoscopic (n = 32) biopsy specimens were used as the reference standard; the results of video-capsule endoscopy (n = 36) and clinical follow-up (n = 59) were used only to confirm the absence of small-bowel disease. RESULTS MR and CT enterography were successfully performed in all 150 patients. Overall sensitivity, specificity, and accuracy, respectively, in identifying patients with small-bowel lesions were 75.9% (41 of 54), 94.8% (91 of 96), and 88.0% (132 of 150) for CT enterography and 92.6% (50 of 54), 99.0% (95 of 96), and 96.7% (145 of 150) for MR enterography. The sensitivity of MR enterography was significantly higher than that of CT enterography for the detection of both overall small-bowel diseases (P = .0159) and neoplastic diseases (P = .0412) but not for the detection of inflammatory diseases (P > .99) or noninflammatory and nonneoplastic diseases (P = .6171). CONCLUSION MR enterography is more accurate than CT enterography in the detection of small-bowel diseases; MR enterography was more accurate in detecting neoplastic diseases in particular.
Collapse
Affiliation(s)
- Gabriele Masselli
- From the Department of Radiology (G.M., E.C., E.P., F.L., R.M., G.G.), Department of Internal Medicine and Medical Specialities (M.D.T.), and Department of General and Special Surgery (M.G.B.), Umberto I Hospital Sapienza University, Viale del Policlinico 155, 00161 Rome, Italy
| | - Marco Di Tola
- From the Department of Radiology (G.M., E.C., E.P., F.L., R.M., G.G.), Department of Internal Medicine and Medical Specialities (M.D.T.), and Department of General and Special Surgery (M.G.B.), Umberto I Hospital Sapienza University, Viale del Policlinico 155, 00161 Rome, Italy
| | - Emanuele Casciani
- From the Department of Radiology (G.M., E.C., E.P., F.L., R.M., G.G.), Department of Internal Medicine and Medical Specialities (M.D.T.), and Department of General and Special Surgery (M.G.B.), Umberto I Hospital Sapienza University, Viale del Policlinico 155, 00161 Rome, Italy
| | - Elisabetta Polettini
- From the Department of Radiology (G.M., E.C., E.P., F.L., R.M., G.G.), Department of Internal Medicine and Medical Specialities (M.D.T.), and Department of General and Special Surgery (M.G.B.), Umberto I Hospital Sapienza University, Viale del Policlinico 155, 00161 Rome, Italy
| | - Francesca Laghi
- From the Department of Radiology (G.M., E.C., E.P., F.L., R.M., G.G.), Department of Internal Medicine and Medical Specialities (M.D.T.), and Department of General and Special Surgery (M.G.B.), Umberto I Hospital Sapienza University, Viale del Policlinico 155, 00161 Rome, Italy
| | - Riccardo Monti
- From the Department of Radiology (G.M., E.C., E.P., F.L., R.M., G.G.), Department of Internal Medicine and Medical Specialities (M.D.T.), and Department of General and Special Surgery (M.G.B.), Umberto I Hospital Sapienza University, Viale del Policlinico 155, 00161 Rome, Italy
| | - Maria Giulia Bernieri
- From the Department of Radiology (G.M., E.C., E.P., F.L., R.M., G.G.), Department of Internal Medicine and Medical Specialities (M.D.T.), and Department of General and Special Surgery (M.G.B.), Umberto I Hospital Sapienza University, Viale del Policlinico 155, 00161 Rome, Italy
| | - Gianfranco Gualdi
- From the Department of Radiology (G.M., E.C., E.P., F.L., R.M., G.G.), Department of Internal Medicine and Medical Specialities (M.D.T.), and Department of General and Special Surgery (M.G.B.), Umberto I Hospital Sapienza University, Viale del Policlinico 155, 00161 Rome, Italy
| |
Collapse
|
9
|
Saini S, Colak E, Anthwal S, Vlachou PA, Raikhlin A, Kirpalani A. Comparison of 3% sorbitol vs psyllium fibre as oral contrast agents in MR enterography. Br J Radiol 2014; 87:20140100. [PMID: 25062448 DOI: 10.1259/bjr.20140100] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
OBJECTIVE To compare the degree of small bowel distension achieved by 3% sorbitol, a high osmolarity solution, and a psyllium-based bulk fibre as oral contrast agents (OCAs) in MR enterography (MRE). METHODS This retrospective study was approved by our institutional review board. A total of 45 consecutive normal MRE examinations (sorbitol, n = 20; psyllium, n = 25) were reviewed. The patients received either 1.5 l of 3% sorbitol or 2 l of 1.6 g kg(-1) psyllium prior to imaging. Quantitative small bowel distension measurements were taken in five segments: proximal jejunum, distal jejunum, proximal ileum, distal ileum and terminal ileum by two independent radiologists. Distension in these five segments was also qualitatively graded from 0 (very poor) to 4 (excellent) by two additional independent radiologists. Statistical analysis comparing the groups and assessing agreement included intraclass coefficients, Student's t-test and Mann-Whitney U-test. RESULTS Small bowel distension was not significantly different in any of the five small bowel segments between the use of sorbitol and psyllium as OCAs in both the qualitative (p = 0.338-0.908) and quantitative assessments (p = 0.083-0.856). The mean bowel distension achieved was 20.1 ± 2.2 mm for sorbitol and 19.8 ± 2.5 mm for psyllium (p = 0.722). Visualization of the ileum was good or excellent in 65% of the examinations in both groups. CONCLUSION Sorbitol and psyllium are not significantly different at distending the small bowel and both may be used as OCAs for MRE studies. ADVANCES IN KNOWLEDGE This is the first study to directly compare the degree of distension in MRE between these two common, readily available and inexpensive OCAs.
Collapse
Affiliation(s)
- Sidharth Saini
- Department of Medical Imaging, St Michael's Hospital and University of Toronto, Toronto, ON, Canada
| | - Errol Colak
- Department of Medical Imaging, St Michael's Hospital and University of Toronto, Toronto, ON, Canada
| | - Shalini Anthwal
- Department of Medical Imaging, St Michael's Hospital and University of Toronto, Toronto, ON, Canada
| | - Paraskevi A Vlachou
- Department of Medical Imaging, St Michael's Hospital and University of Toronto, Toronto, ON, Canada
| | - Antony Raikhlin
- Department of Medical Imaging, St Michael's Hospital and University of Toronto, Toronto, ON, Canada
| | - Anish Kirpalani
- Department of Medical Imaging, St Michael's Hospital and University of Toronto, Toronto, ON, Canada
| |
Collapse
|
10
|
Small Bowel Imaging: Clinical Applications of the Different Imaging Modalities—A Comprehensive Review. ACTA ACUST UNITED AC 2013. [DOI: 10.1155/2013/419542] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
In the last years, MR and CT techniques have been optimized for small bowel imaging and are playing an increasing role in the evaluation of small bowel disorders. In comparison to traditional barium fluoroscopic examinations, spatial and temporal resolution is now much more improved partially thanks to modern bowel distending agents. However, there is a global interest in implementing techniques that either reduce or eliminate radiation exposure. This is especially important in patients with chronic diseases such as inflammatory bowel disease who may require multiple studies over a lifetime. Owing to the excellent soft tissue contrast, direct multiplanar imaging capabilities, new ultrafast breath-holding pulse sequences, lack of ionizing radiation, and availability of a variety of oral contrast agents, MR is well suited to play a critical role in the imaging of small bowel disorders.
Collapse
|
11
|
Abstract
Small-bowel radiology has undergone dramatic changes in the past 2 decades. Despite important recent advances in small-bowel endoscopy, radiologic imaging remains important for patients suspected of having or with established small-bowel disease. Cross-sectional imaging techniques (computed tomography and magnetic resonance [MR] imaging), used to investigate both extraluminal abnormalities and intraluminal changes, have gradually replaced barium contrast examinations, which are, however, still used to examine early mucosal disease. MR imaging techniques clearly highlight endoluminal, mural and extramural enteric details and provide vascular and functional information, thereby enhancing the diagnostic value of these techniques in small-bowel diseases. Two MR imaging based techniques are currently utilized: MR enteroclysis and MR enterography. In enteroclysis, enteric contrast material is administered through a nasoenteric tube, whereas in enterography, large volumes of enteric contrast material are administered orally. MR enteroclysis ensures consistently better luminal distention than does MR enterography in both the jejunum and the ileum and more accurately depicts endoluminal abnormalities and early disease, particularly at the level of the jejunal loops. Moreover, MR enteroclysis provides a high level of accuracy in the diagnosis and exclusion of small-bowel inflammatory and neoplastic diseases and can be used for the first radiologic evaluation, while MR enterography may effectively be used to follow up both Crohn disease patients without jejunal disease and in pediatric patients where nasogastric intubation might be a problem. MR enteroclysis may also reveal subtle transition points or an obstruction in the lower small bowel, which may escape detection when more routine methods, including enterography, are used. MR imaging offers detailed morphologic information and functional data of small-bowel diseases and provides reliable evidence of normalcy, thereby allowing the diagnosis of early or subtle structural abnormalities and guiding treatment and decisions in patient care.
Collapse
Affiliation(s)
- Gabriele Masselli
- Department of Radiology, Università di Roma Sapienza, Viale del Policlinico, Rome, Italy.
| | | |
Collapse
|
12
|
D'Ippolito G, Braga FA, Resende MC, Bretas EAS, Nunes TF, Rosas GDQ, Tiferes DA. Enterografia por tomografia computadorizada: uma avaliação de diferentes contrastes orais neutros. Radiol Bras 2012. [DOI: 10.1590/s0100-39842012000300004] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
OBJETIVO: O objetivo deste estudo foi avaliar o desempenho de contrastes orais neutros, comparando a capacidade de distensão intestinal, a distinção da parede intestinal, a aceitação e os efeitos colaterais. MATERIAIS E MÉTODOS: Estudo prospectivo, randomizado e duplo-cego em 30 pacientes submetidos a tomografia computadorizada de abdome e pelve com administração de contraste oral neutro, divididos em três grupos: leite, água e polietilenoglicol. Os exames foram analisados quanto ao grau de distensão intestinal e distinção da parede intestinal por dois examinadores em consenso. Os pacientes responderam a um questionário referente ao sabor da solução ingerida e efeitos colaterais. Foram utilizados os testes Kruskal-Wallis e qui-quadrado para as análises estatísticas. RESULTADOS: Distensão intestinal adequada (calibre da alça maior que 2 cm) foi observada em 14 segmentos dos 40 estudados (35%) no grupo leite, em 10 segmentos (25%) no grupo água e em 23 segmentos (57%) no grupo polietilenoglicol (p = 0,01). O preparo com polietilenoglicol resultou na melhor distensão intestinal, porém apresentou o pior sabor e maior incidência de diarreia, referidos pelos pacientes. CONCLUSÃO: O preparo oral com polietilenoglicol promove maior grau de distensão intestinal do que quando se utiliza água ou leite, mas tem pior aceitação, relacionada ao seu sabor e frequência de diarreia.
Collapse
|
13
|
Mirk P, Foschi R, Minordi LM, Vecchioli Scaldazza A, De Vitis I, Guidi L, Bonomo L. Sonography of the small bowel after oral administration of fluid: an assessment of the diagnostic value of the technique. Radiol Med 2011; 117:558-74. [PMID: 22095418 DOI: 10.1007/s11547-011-0749-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2011] [Accepted: 04/26/2011] [Indexed: 12/13/2022]
Abstract
PURPOSE This study was performed to assess the feasibility and possible advantages of bowel sonography after fluid filling of intestinal loops compared with conventional sonography. MATERIALS AND METHODS Forty-five consecutive patients with known or suspected coeliac disease (35 females, ten males; age range 11-65 years) prospectively underwent sonography before and after ingestion of 750 ml of an aqueous solution of polyethylene glycol. Results before and after fluid distension were compared to assess whether luminal filling improved small-bowel visualisation. RESULTS Luminal filling improved visualisation of intestinal features (luminal diameter, mucosal folds, parietal layers) in 77.6% of cases (marked, moderate or mild improvement in 2, 16 and 17 patients; 4.4%, 35.5% and 37.7%), respectively, and showed no change or worsening in 20% and 2.2% nine and one patient), respectively. Baseline examination showed abnormal features in 13/25 celiac patients (dilated fluid-filled loops, increased peristalsis, transient intussusception, mesenteric lymph nodes, intraperitoneal fluid). Reexamination after luminal filling showed additional abnormalities in six of the previous 13 and in three further coeliac patients. There were no false positive signs due to fluid administration. CONCLUSIONS Luminal filling can improve visualisation of bowel walls and fold pattern and may be helpful in selected cases.
Collapse
Affiliation(s)
- P Mirk
- Dipartimento di Bio-immagini e Scienze Radiologiche, Università Cattolica del Sacro Cuore, Largo Gemelli 8, 00168, Roma, Italy.
| | | | | | | | | | | | | |
Collapse
|
14
|
Fornasa F, Benassuti C, Benazzato L. Role of Magnetic Resonance Enterography in Differentiating between Fibrotic and Active Inflammatory Small Bowel Stenosis in Patients with Crohn's Disease. J Clin Imaging Sci 2011; 1:35. [PMID: 21966632 PMCID: PMC3177410 DOI: 10.4103/2156-7514.82339] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2011] [Accepted: 06/09/2011] [Indexed: 01/06/2023] Open
Abstract
Objective: To assess the diagnostic accuracy of magnetic resonance imaging (MRI) in prospectively differentiating between fibrotic and active inflammatory small bowel stenosis in patients with Crohn's disease (CD). Materials and Methods: A total of 111 patients with histologically proven CD presenting with clinical and plain radiographic signs of small bowel obstruction underwent coronal and axial MRI scans after oral administration of polyethylene glycol solution. A stenosis was judged present if a small bowel segment had >80% lumen reduction as compared to an adjacent normal loop and mural thickening of >3 mm. At the level of the stenosis, both T2 signal intensity and post-gadolinium T1 enhancement were quantified using a 5-point scale (0: very low; 1: low; 2: moderate; 3: high; and 4: very high). A stenosis was considered fibrotic if the sum of the two values (activity score: AS) did not exceed 1. Results: A small bowel stenosis was identified in 48 out of 111 patients. Fibrosis was confirmed at histology in all of the 23 patients with AS of 0 or 1, who underwent surgery within 3 days of the MRI examination. In the remaining 25 patients (AS: 2–8), an active inflammatory stenosis was suspected and remission of the obstructive symptoms was obtained by means of medical treatment. One of these patients (AS: 2), however, underwent surgery after 14 days, due to recurrence. MRI had 95.8% sensitivity, 100% specificity, and 97.9% accuracy in the diagnosis of fibrotic stenosis. Conclusion: MRI is reliable in differentiating fibrotic from inflammatory small bowel stenosis in CD.
Collapse
Affiliation(s)
- Francesca Fornasa
- Department of Radiology, San Bonifacio Hospital, 37042 San Bonifacio (Verona), Italy
| | | | | |
Collapse
|
15
|
Soyer P, Boudiaf M, Fishman EK, Hoeffel C, Dray X, Manfredi R, Marteau P. Imaging of malignant neoplasms of the mesenteric small bowel: new trends and perspectives. Crit Rev Oncol Hematol 2010; 80:10-30. [PMID: 21035353 DOI: 10.1016/j.critrevonc.2010.09.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2010] [Revised: 09/29/2010] [Accepted: 09/30/2010] [Indexed: 12/13/2022] Open
Abstract
This article describes the recent advances in radiological imaging of malignant neoplasms of the mesenteric small bowel and provides an outline of new trends and perspectives that can be anticipated. The introduction of multidetector row technology, which allows the acquisition of submillimeter and isotropic voxels, has dramatically improved the capabilities of computed tomography in the investigation of the mesenteric small bowel. This technology combined with optimal filling of small bowel loops through the use of appropriate enteral contrast agents has markedly changed small bowel imaging. Computed tomography-enteroclysis, which is based on direct infusion of enteral contrast agent into the mesenteric small bowel through a naso-jejunal tube, provides optimal luminal distension. By contrast, computed tomography-enterography is based on oral administration of enteral contrast agent. These two techniques are now well-established ones for the detection and the characterization of small bowel neoplasms. During the same time, combining the advantages of unsurpassed soft tissue contrast and lack of ionizing radiation, magnetic resonance imaging has gained wide acceptance for the evaluation of patients with suspected small bowel neoplasms. Rapid magnetic resonance imaging sequences used in combination with specific enteral contrast agents generate superb images of the mesenteric small bowel so that magnetic resonance-enteroclysis and magnetic resonance-enterography are now considered as effective diagnostic tools for both the detection and the characterization of neoplasms of the mesenteric small bowel. Recent improvements in image post-processing capabilities help obtain realistic three-dimensional representations of tumors and virtual enteroscopic views of the small bowel that are useful for the surgeon and the gastroenteroenteologist to plan surgical or endoscopic interventions. Along with a better knowledge of the potential and limitations of wireless capsule endoscopy and new endoscopic techniques, these recent developments in radiological imaging reasonably suggest that substantial changes in the investigation of small bowel tumors may be anticipated in a near future, thus potentially create a new paradigm shift after standard small bowel follow-through study has been universally abandoned.
Collapse
Affiliation(s)
- Philippe Soyer
- Department of Abdominal Imaging, Hôpital Lariboisière-AP-HP and Université Diderot-Paris, France.
| | | | | | | | | | | | | |
Collapse
|
16
|
Masselli G, Picarelli A, Di Tola M, Libanori V, Donato G, Polettini E, Piermattei A, Palumbo P, Pittalis A, Saponara A, Gualdi G. Celiac disease: evaluation with dynamic contrast-enhanced MR imaging. Radiology 2010; 256:783-90. [PMID: 20663971 DOI: 10.1148/radiol.10092160] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
PURPOSE To prospectively determine mural perfusion dynamics in patients with untreated celiac disease by using dynamic contrast material-enhanced magnetic resonance (MR) imaging and to compare these dynamics with those in a control population and in patients with celiac disease treated with a gluten-free diet. MATERIALS AND METHODS Institutional review board approval and informed consent from all participants were obtained. Sixty consecutive patients with untreated celiac disease, 45 patients with celiac disease treated with a gluten-free diet for at least 1 year, and 30 control subjects were enrolled in this study. Dynamic contrast-enhanced MR imaging was performed by using a 1.5-T MR unit. For each MR imaging examination, maximum enhancement, slope of enhancement, and time-signal intensity curves were calculated at the level of the descending duodenal wall. Duodenal wall thickness was also evaluated. Statistical evaluation was performed by using one-way analysis of variance, and the results were confirmed by using the Bartlett test for equal variances and complemented by using Bonferroni multiple comparison, linear correlation, and the Student t test for paired data. RESULTS Mean maximum enhancement of the duodenal wall was significantly higher in patients with untreated celiac disease (229.1 +/- 46.4 [standard deviation]) than in patients with treated celiac disease (109.8 +/- 27.8) and control subjects (94.7 +/- 17.9) (P < .001 for each comparison). All 60 untreated patients showed a curve characterized by fast enhancement and washout (type 4), while all 45 treated patients and the 30 control subjects showed a curve characterized by slow constant enhancement (type 2). Mean duodenal wall thickness was not significantly different between untreated patients (2.2 mm +/- 0.4), treated patients (2.0 mm +/- 0.3), and control subjects (2.0 mm +/- 0.4) (one-way analysis of variance, P = .4177; Bartlett test, P = .6951). CONCLUSION The results of this study suggest that dynamic evaluation of the bowel wall by using contrast-enhanced MR imaging can be an effective and reproducible way to show the inflammation state in celiac disease.
Collapse
Affiliation(s)
- Gabriele Masselli
- Department of Radiology, Gastroenterology, and Surgery, Umberto I Hospital, La Sapienza University, Rome, Italy.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Abstract
Cross-sectional imaging techniques are playing an increasing role in the evaluation of suspected small-bowel disorders, and a growing awareness of the risks of ionizing radiation exposure has prompted the exploration of alternative imaging techniques. Advantages of magnetic resonance (MR) imaging include a lack of ionizing radiation, the ability to provide dynamic information regarding bowel distention and motility, improved soft-tissue contrast, and a relatively safe intravenous contrast agent profile. Limitations of MR imaging include cost, imager access, variability in examination quality, and lower spatial and temporal resolution compared with those of computed tomography (CT). MR imaging of the small bowel is indicated for patients with Crohn disease, those for whom exposure to radiation is a concern, those with contraindications to CT, and those with low-grade small-bowel obstruction. MR imaging may be performed with enterography or enteroclysis. In enterography, large volumes of fluid are ingested. Several different contrast agents may be used. These agents are classified according to their signal intensity on T1- and T2-weighted images. In enteroclysis, enteric contrast material is administered through a nasoenteric tube. Crohn disease is the primary indication for MR imaging of the small bowel because many patients require multiple follow-up examinations. Findings suggestive of active inflammation include bowel wall thickening and hyperenhancement, ulcerations, increased mesenteric vascularity, and perienteric inflammation. Complications are well depicted and may include penetrating disease and small-bowel obstruction.
Collapse
Affiliation(s)
- Jeff L Fidler
- Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA.
| | | | | |
Collapse
|
18
|
Cronin CG, Lohan DG, Browne AM, Roche C, Murphy JM. Magnetic Resonance Enterography in the Evaluation of the Small Bowel. Semin Roentgenol 2009; 44:237-43. [DOI: 10.1053/j.ro.2009.05.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
19
|
Abstract
CT enterography (CTE) is a technique using neutral oral contrast, intravenous contrast and thin cut, multiplanar CT acquisitions to optimize small bowel imaging. One of the primary indications for CTE is the detection and evaluation of Crohn's disease. This article summarizes the advantages/disadvantages, scanning technique, imaging findings, performance and pitfalls of CTE for the evaluation of Crohn's disease.
Collapse
Affiliation(s)
- Amy K Hara
- Diagnostic Radiology, Mayo Clinic, Scottsdale, AZ 85259, USA.
| | | |
Collapse
|
20
|
Masselli G, Polettini E, Casciani E, Bertini L, Vecchioli A, Gualdi G. Small-bowel neoplasms: prospective evaluation of MR enteroclysis. Radiology 2009; 251:743-50. [PMID: 19304922 DOI: 10.1148/radiol.2513081819] [Citation(s) in RCA: 102] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE To prospectively evaluate the accuracy of magnetic resonance (MR) enteroclysis in the detection of small-bowel neoplasms in symptomatic patients, with conventional endoscopy, tissue specimen, capsule endoscopy, conventional enteroclysis, and follow-up findings as reference standards. MATERIALS AND METHODS The study protocol was approved by the human research committee, and all patients gave written informed consent. One hundred fifty patients (83 male, 67 female; mean age, 42.6 years; age range, 17-84 years) who were clinically suspected of having small-bowel neoplasm and whose previous upper and lower gastrointestinal endoscopy findings were normal underwent MR enteroclysis. The MR enteroclysis findings were prospectively evaluated for the presence of focal bowel wall thickening, small-bowel masses, and small-bowel stenosis. Positive MR enteroclysis findings were compared with histopathologic examination results obtained after surgical (n = 19) or endoscopic (n = 2) procedures. Negative MR enteroclysis results were compared with the results of enteroscopy (n = 5), capsule endoscopy (n = 53), or conventional enteroclysis with subsequent clinical follow-up (n = 71). The diagnostic performance of MR enteroclysis was analyzed on a per-patient basis. RESULTS MR enteroclysis was successfully completed in all 150 patients and enabled correct detection of 19 small-bowel neoplasms, which were confirmed at histopathologic examination: three carcinoid neoplasms, two adenocarcinomas, two stromal tumors, five lymphomas, one angiomatous mass, three small-bowel metastases, one leiomyoma, one adenoma, and one lipoma. Overall sensitivity, specificity, and accuracy in identifying patients with small-bowel lesions were 86% (19 of 22), 98% (126 of 128), and 97% (145 of 150), respectively. Two MR enteroclysis examinations yielded false-positive findings, and three yielded false-negative findings. CONCLUSION MR enteroclysis is an accurate modality for detecting small-bowel neoplasms in symptomatic patients.
Collapse
Affiliation(s)
- Gabriele Masselli
- Department of Radiology, Umberto I Hospital, La Sapienza University, Viale del Policlinico 155, 00161 Rome, Italy.
| | | | | | | | | | | |
Collapse
|
21
|
Affiliation(s)
- Andrea Laghi
- Department of Radiological Sciences, Sapienza, University of Rome, Polo Pontino, ICOT Hospital, Latina, Italy.
| | | | | |
Collapse
|
22
|
MR imaging of the small bowel in Crohn's disease. Eur J Radiol 2008; 69:409-17. [PMID: 19118967 DOI: 10.1016/j.ejrad.2008.11.013] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2008] [Accepted: 11/13/2008] [Indexed: 12/24/2022]
Abstract
MR and CT techniques optimized for small bowel imaging are playing an increasing role in the evaluation of small bowel disorders. Several studies have shown the advantage of these techniques over tradition barium fluoroscopic examinations secondary to improvements in spatial and temporal resolution combined with improved bowel distending agents. The preference of MR vs. CT has been geographical and based on expertise and public policy. With the increasing awareness of radiation exposure, there has been a more global interest in implementing techniques that either reduce or eliminate radiation exposure [Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med 2007;357:2277-84]. This is especially important in patients with chronic diseases such as inflammatory bowel disease who may require multiple studies over a lifetime or in studies that require sequential imaging time points such as in assessment of gastrointestinal motility [Froehlich JM, Patak MA, von Weymarn C, Juli CF, Zollikofer CL, Wentz KU. Small bowel motility assessment with magnetic resonance imaging. J Magn Reson Imaging 2005;21:370-75]. A recent study showed that certain subgroups of patients with Crohn's disease may be exposed to higher doses of radiation; those diagnosed at an early age, those with upper tract inflammation, penetrating disease, requirement of intravenous steroids, infliximab or multiple surgeries [Desmond AN, O'Regan K, Curran C, et al. Crohn's disease: factors associated with exposure to high levels of diagnostic radiation. Gut 2008;57:1524-29]. Therefore it has been suggested that techniques that can reduce or eliminate radiation exposure should be considered for imaging [Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med 2007;357:2277-84]. Owing to the excellent softtissue contrast, direct multiplanar imaging capabilities, new ultrafast breath-holding pulse sequences, lack of ionizing radiation and availability of a variety of oral contrast agents, MR is well suited to play a critical role in the imaging of small bowel disorders. In this article we will review the technical issues related to the performance of MR enterography and enteroclysis and discuss the role and controversies of using MR in the assessment of inflammatory bowel disease.
Collapse
|
23
|
Kinner S, Kuehle CA, Herbig S, Haag S, Ladd SC, Barkhausen J, Lauenstein TC. MRI of the small bowel: can sufficient bowel distension be achieved with small volumes of oral contrast? Eur Radiol 2008; 18:2542-8. [PMID: 18500525 DOI: 10.1007/s00330-008-1041-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2008] [Accepted: 03/10/2008] [Indexed: 01/09/2023]
Abstract
Sufficient luminal distension is mandatory for small bowel imaging. However, patients often are unable to ingest volumes of currently applied oral contrast compounds. The aim of this study was to evaluate if administration of low doses of an oral contrast agent with high-osmolarity leads to sufficient and diagnostic bowel distension. Six healthy volunteers ingested at different occasions 150, 300 and 450 ml of a commercially available oral contrast agent (Banana Smoothie Readi-Cat, E-Z-EM; 194 mOsmol/l). Two-dimensional TrueFISP data sets were acquired in 5-min intervals up to 45 min after contrast ingestion. Small bowel distension was quantified using a visual five-grade ranking (5 = very good distension, 1 = collapsed bowel). Results were statistically compared using a Wilcoxon-Rank test. Ingestion of 450 ml and 300 ml resulted in a significantly better distension than 150 ml. The all-over average distension value for 450 ml amounted to 3.4 (300 ml: 3.0, 150 ml: 2.3) and diagnostic bowel distension could be found throughout the small intestine. Even 45 min after ingestion of 450 ml the jejunum and ileum could be reliably analyzed. Small bowel imaging with low doses of contrast leads to diagnostic distension values in healthy subjects when a high-osmolarity substance is applied. These findings may help to further refine small bowel MRI techniques, but need to be confirmed in patients with small bowel disorders.
Collapse
Affiliation(s)
- Sonja Kinner
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
| | | | | | | | | | | | | |
Collapse
|
24
|
Rimola J, Rodríguez S, Ayuso C. [Magnetic resonance enterography in Crohn's disease: a new diagnostic tool?]. Med Clin (Barc) 2008; 130:580-4. [PMID: 18462637 DOI: 10.1157/13119980] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Jordi Rimola
- Sección de Abdomen (TC/RM), Servicio de Radiodiagnóstico, Hospital Clínic, Barcelona, Spain.
| | | | | |
Collapse
|
25
|
Abstract
Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as “good” in 78% of the examinations performed with preparation and 49% performed without (P < 0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum.
Collapse
|
26
|
Paolantonio P, Tomei E, Rengo M, Ferrari R, Lucchesi P, Laghi A. Adult celiac disease: MRI findings. ACTA ACUST UNITED AC 2008; 32:433-40. [PMID: 16967239 DOI: 10.1007/s00261-006-9089-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
The purpose of our report is to describe a spectrum of findings of celiac disease at MR enterography. MR enterography is a non-invasive, feasible, and reproducible imaging technique for the evaluation of small bowel. Findings on MR enterography, similar to those of conventional barium studies, may suggest a diagnosis of celiac disease.
Collapse
Affiliation(s)
- Pasquale Paolantonio
- Department of Radiological Sciences, University of Rome La Sapienza, PoloPontino, Latina, Italy.
| | | | | | | | | | | |
Collapse
|
27
|
|
28
|
Herrmann KA, Michaely HJ, Zech CJ, Seiderer J, Reiser MF, Schoenberg SO. Internal fistulas in Crohn disease: magnetic resonance enteroclysis. ACTA ACUST UNITED AC 2007; 31:675-87. [PMID: 16447079 DOI: 10.1007/s00261-005-0400-y] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Internal fistulas (IFs) and abscesses are the most common complications of Crohn disease (CD). To reliably diagnose and clearly distinguish inflammatory or fibrostenotic manifestations of CD from its complications is of paramount importance to appropriately guide therapeutic decisions. Magnetic resonance enteroclysis (MRE), a recently introduced technique for small bowel imaging, has proved a high efficacy in the depiction of luminal and extraluminal manifestations of CD and holds great promise as a powerful diagnostic tool in the comprehensive diagnostic workup of this disease. As of yet, the characteristic imaging appearance of IFs on MRE has not been described in detail. This article reviews the performance of conventional imaging techniques and the current potential of MRE in the depiction of IFs in CD. Typical imaging morphology and characteristic imaging findings of IFs on MRE are described in detail and a newly defined and highly indicative imaging finding, the "star-sign," is presented and discussed.
Collapse
Affiliation(s)
- K A Herrmann
- Institute of Clinical Radiology, University Hospitals Grosshadern, Ludwig-Maximilians-University Munich, Marchioninistr. 15, D-81377 Munich, Germany.
| | | | | | | | | | | |
Collapse
|
29
|
Masselli G, Casciani E, Polettini E, Gualdi G. Comparison of MR enteroclysis with MR enterography and conventional enteroclysis in patients with Crohn's disease. Eur Radiol 2007; 18:438-47. [PMID: 17899102 DOI: 10.1007/s00330-007-0763-2] [Citation(s) in RCA: 165] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2007] [Revised: 07/19/2007] [Accepted: 08/27/2007] [Indexed: 12/29/2022]
Abstract
To prospectively compare the diagnostic accuracy of MR enteroclysis with duodenal intubation with MRI after drinking oral contrast agent only (MR enterography) with conventional enteroclysis (conv-E) as reference standard in patients with Crohn's disease. Forty consecutive patients (22 males and 18 females; mean age 36; range 16-74 years) with proven Crohn's disease underwent conv-E and MR imaging. Twenty-two patients underwent MR enteroclysis with intubation (MRE) and 18 underwent MR-enterography (MR per OS). Two radiologists reached a consensus about the following imaging findings: luminal distension and visualization of superficial mucosal, mural and mesenteric abnormalities. Standard descriptive statistics and a Wilcoxon rank sum test were used. Statistical significance was inferred at P < 0.05. There was no significant difference in the adequacy of luminal distention between the MRE and conv-E (P = 0.08), and both were statistically superior in comparison to MR per OS in the distension of the jejunum (P < 0.01) and less significant at the ileum and terminal ileum levels (P < 0.05). MRE and conv-E were comparable for the accuracy of superficial mucosal abnormalities; meanwhile conv-E compared with MR per OS was statistically superior (P < 0.01). MRE compared with MR per OS was statistically better when visualizing superficial abnormalities (P < 0.01). No statistically significant differences were found in assessing the diagnostic efficacy between MR examinations for the depiction of mural stenosis (P = 0.105) and fistulae (P = 0.67). The number of detected mesenteric findings was significantly higher with both MRE and MR per OS compared to conv-E (P < 0.01). MRE can serve as the diagnostic procedure for initially evaluating patients suspected of having Crohn's disease. MR per OS may have a role in patients that refuse or have failed intubation and also for follow-up.
Collapse
Affiliation(s)
- Gabriele Masselli
- Radiology DEA Department, Academic Hospital Umberto I. La Sapienza University Rome, Viale del Policlinico 155, 00161 Rome, Italy.
| | | | | | | |
Collapse
|
30
|
Lohan D, Cronin C, Meehan C, Alhajeri AN, Roche C, Murphy J. MR small bowel enterography: optimization of imaging timing. Clin Radiol 2007; 62:804-7. [PMID: 17604772 DOI: 10.1016/j.crad.2007.02.010] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2006] [Revised: 01/15/2007] [Accepted: 02/04/2007] [Indexed: 11/19/2022]
Affiliation(s)
- D Lohan
- Department of Radiology, University College Hospital, Galway, Ireland.
| | | | | | | | | | | |
Collapse
|
31
|
Abstract
Cross-sectional imaging techniques such as CT and MR imaging have advantages over traditional barium fluoroscopic techniques in their ability to visualize superimposed bowel loops better and to improve visualization of extraluminal findings and complications. This article discusses MR imaging of the small bowel with enterography and enteroclysis techniques. It reviews the advantages, limitations, technique, and indications and reviews the results that have been obtained in evaluating different disease processes.
Collapse
Affiliation(s)
- Jeff Fidler
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
| |
Collapse
|
32
|
Babos M, Schwarcz A, Randhawa MS, Marton B, Kardos L, Palkó A. In vitro evaluation of alternative oral contrast agents for MRI of the gastrointestinal tract. Eur J Radiol 2007; 65:133-9. [PMID: 17485189 DOI: 10.1016/j.ejrad.2007.03.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2006] [Revised: 01/14/2007] [Accepted: 03/21/2007] [Indexed: 11/24/2022]
Abstract
PURPOSE In vitro evaluation of different materials as potential alternative oral contrast agents for small bowel MRI. MATERIALS AND METHODS The T1 and T2 relaxation times of rose hip syrup, black currant extract, cocoa, iron-deferoxamine solution and a commonly used oral contrast material (1 mM Gd-DTPA) were determined in vitro at different concentrations on a 1.0 T clinical MR scanner. T1 values were obtained with an inversion prepared spoiled gradient echo sequence. T2 values were obtained using multiple echo sequences. Finally the materials were visualized on T1-, T2- and T2*-weighted MR images. RESULTS The relaxation times of the undiluted rose hip syrup (T1=110+/-5 ms, T2=86+/-3 ms), black currant extract (T1=55+/-3 ms, T2=39+/-2 ms) and 5 mM iron-deferoxamine solution (T1=104+/-4 ms, T2=87+/-2 ms) were much shorter than for a 1mM Gd-DTPA solution (T1=180+/-8 ms, T2=168+/-5 ms). Dilution of black currant extract to 30% or a 3 mM iron-deferoxamine solution conducted to T1 relaxation times which are quite comparable to a 1 mM Gd-DTPA solution. Despite its much lower metal content an aqueous cocoa suspension (100 g/L) produced T2 relaxation times (T1=360+/-21 ms, T2=81+/-3 ms) more or less in the same range like the 5 mM iron-deferoxamine solution. Imaging of our in vitro model using clinical sequences allowed to anticipate the T1-, T2- and T2*-depiction of all used substances. Cocoa differed from all other materials with its low to moderate signal intensity on T1- and T2-weighted sequences. While all substances presented a linear 1/T1 and 1/T2 relationship towards concentration, rose hip syrup broke ranks with a disproportionately high increase of relaxation at higher concentrations. CONCLUSIONS Rose hip syrup, black currant extract and iron-deferoxamine solution due to their positive T1 enhancement characteristics and drinkability appear to be valuable oral contrast agents for T1-weighted small bowel MRI. Cocoa with its differing relaxation and signal enhancement properties is a promising oral contrast agent but needs further clinical evaluation.
Collapse
Affiliation(s)
- Magor Babos
- University of Szeged, Faculty of Science, Hungary.
| | | | | | | | | | | |
Collapse
|
33
|
Masselli G, Vecchioli A, Gualdi GF. Crohn disease of the small bowel: MR enteroclysis versus conventional enteroclysis. ACTA ACUST UNITED AC 2007; 31:400-9. [PMID: 16447084 DOI: 10.1007/s00261-005-0395-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Enteroclysis has been suggested as the technique of choice for the evaluation of Crohn disease of the small intestine. Adequate distention of the entire small bowel with barium suspension allows the radiologic demonstration of mucosal abnormalities and provides functional information by defining distensibility or fixation of the small bowel loops. The principal disadvantage of conventional enteroclysis is the limited indirect information on the state of the bowel wall and extramural extension of Crohn disease, and its effectiveness may be hindered owing to overlapping bowel loops. Moreover, the radiation dose administered to patients, mostly at a young age, should be considered. Magnetic resonance (MR) enteroclysis is an emerging technique for small bowel imaging and was introduced to overcome the limitations of conventional enteroclysis and MR cross-sectional imaging by combining the advantages of both into one technique. MR enteroclysis has the potential to change how the small bowel is assessed because of the functional information, soft tissue contrast, direct multiplanar imaging capabilities, and lack of ionizing radiation.
Collapse
Affiliation(s)
- G Masselli
- Radiology Emergency Department, "Umberto I" Academic Hospital "La Sapienza University", Viale del Policlinico 155, 00161, Rome, Italy.
| | | | | |
Collapse
|
34
|
Kuehle CA, Ajaj W, Ladd SC, Massing S, Barkhausen J, Lauenstein TC. Hydro-MRI of the small bowel: effect of contrast volume, timing of contrast administration, and data acquisition on bowel distention. AJR Am J Roentgenol 2006; 187:W375-85. [PMID: 16985108 DOI: 10.2214/ajr.05.1079] [Citation(s) in RCA: 87] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVE The purpose of this study was to assess oral contrast agents, volumes of the agents, and time points of data acquisition in regard to small-bowel distention and patient acceptance. SUBJECTS AND METHODS Six healthy volunteers underwent imaging on 16 different days. Four volumes (450, 900, 1,350, and 1,800 mL) of each of the four contrast compounds (0.2% locust bean gum plus 2.5% mannitol, VoLumen containing 2.0% sorbitol, VoLumen containing 1.4% sorbitol, and tap water) were used. Two-dimensional true fast imaging with steady-state free precession data sets were acquired at 5-minute intervals after contrast ingestion. Distention values for small-bowel segments (duodenum, proximal and distal jejunum, ileum) and occurrence of side effects were documented. RESULTS Analysis of bowel distention revealed significantly greater distention for all carbohydrate sugar alcohol-containing solutions compared with water but no significant difference among the three contrast agents. Sufficient duodenal distention was achieved with 900 mL of any of the contrast agents, but imaging had to be performed soon after ingestion. For MRI of the distal jejunum and ileum, a volume of 1,350 mL is preferable, and the time point of data acquisition plays a minor role. Ingestion of 1,800 mL of the carbohydrate sugar alcohol solutions led to a significantly higher rate of side effects such as abdominal cramps than did ingestion of smaller volumes. CONCLUSION The data indicate that sufficient contrast consumption and optimal timing of data acquisition are essential to distention of the small bowel. Oral contrast agent protocols should be adapted to the bowel region in question.
Collapse
Affiliation(s)
- Christiane A Kuehle
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, D-45122 Essen, Germany.
| | | | | | | | | | | |
Collapse
|
35
|
Masselli G, Casciani E, Polettini E, Lanciotti S, Bertini L, Gualdi G. Assessment of Crohn's disease in the small bowel: Prospective comparison of magnetic resonance enteroclysis with conventional enteroclysis. Eur Radiol 2006; 16:2817-27. [PMID: 16799782 DOI: 10.1007/s00330-006-0338-7] [Citation(s) in RCA: 78] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2005] [Revised: 04/28/2006] [Accepted: 05/09/2006] [Indexed: 02/06/2023]
Abstract
Our objective was to assess the diagnostic value of magnetic resonance enteroclysis (MRE) compared with conventional enteroclysis (CE) in patients with Crohn's disease. A secondary objective was to evaluate the diagnostic accuracy of each different MR sequence. Sixty-six consecutive patients with known Crohn's disease underwent MRE and CE. Fast imaging employing steady-state acquisition (FIESTA), single-shot fast spin-echo (ssFSE), and contrast-enhanced T1-weighted sequences were assessed by two radiologists who reached a consensus about the following findings: visualization of wall ulcers, pseudopolyps, fistulae, mural stenosis, and mesenteric abnormalities. Standard descriptive statistics and the McNemar test were used. The sensitivity, specificity and accuracy of MRE were 90-87% and 83% for the depiction of parietal ulcers, 84%-88% and 86% for pseudopolyps, 100-94% and 96% for mural stenosis, 93-100% and 94% for fistulae. The number of detected extraluminal findings was significantly higher with MRE (P < 0.01). The accuracy of FIESTA sequence was statistically higher in the depiction of wall ulcers and fistulae than that of three-dimensional fast spoiled gradient echo (3D-FSPGR) (P < 0.01) and ssFSE (P < 0.05) sequences. Contrast-enhanced 3D-FSPGR was superior for mural stenosis visualization compared to ssFSE (P < 0.05) and FIESTA (P < 0.05). MRE correlates accurately with CE in the detection of superficial and transmural abnormalities and has the advantage of assessing the mesenteric manifestations.
Collapse
Affiliation(s)
- Gabriele Masselli
- Radiology DEA Department, Umberto I Academic Hospital, University La Sapienza, Viale del Policlinico, 155-00161 Rome, Italy.
| | | | | | | | | | | |
Collapse
|
36
|
Godefroy C, Pilleul F, Dugougeat F, Yzèbe D, Lachaux A, Pracros JP, Valette PJ. [Value of contrast-enhanced MR enterography in pediatric Crohn's disease: preliminary study]. ACTA ACUST UNITED AC 2006; 86:1685-92. [PMID: 16269980 DOI: 10.1016/s0221-0363(05)81508-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVE Feasibility study of contrast enhanced MR enterography without enteroclysis as a new diagnostic tool for children with known or suspected Crohn's disease. METHODS We prospectively included 15 children, 8-18 years old, with clinical suspicion of Crohn's disease. MR enterography without enteroclysis was performed on a 1,5 T clinical MR system. A total of 1000 ml of mannitol 5% was orally administered 60 minutes prior to MRI. Coronal and axial breath-hold sequences were acquired. The following sequences were obtained: True-FISP, FLASH T1 2D/3D with Fat saturation before and after gadolinium injection. Two radiologists, blinded to patient information, independently reviewed all examinations to record image quality, the degree of distension of the distal ileum, the presence of abnormal bowel segments and the presence of extra-intestinal complications. MRI findings were correlated to sonographic, endoscopic and biological results (sensitivity, specificity, Kappa test). RESULTS The examinations were considered of satisfactory diagnostic quality in 93.3% of patients. Respiratory artifacts were present in one case. The entire GI tract could be identified on all sequences. Distention of the distal ileum was recorded as good to excellent in 89% of healthy subjects. Five MR examinations were considered abnormal with isolated ileal involvement in 2 cases, ileocolic involvement in 2 cases, and isolated colonic involvement in 1 case. The sensitivity and specificity of MR for the positive diagnosis of Crohn's disease were 100% and 83% respectively. Three extra-intestinal complications were detected: one case of ileo-ileal fistula, not identified on ultrasonography, an asymptomatic anal fistula and a symptomatic inflammatory stricture. CONCLUSION MR enterography without enteroclysis is a well tolerated, effective non invasive method in the evaluation of known or suspected Crohn's disease. Because of the absence of ionizing radiation, MR enterography should become the gold standard in pediatric patients.
Collapse
Affiliation(s)
- C Godefroy
- Service de Radiologie Pédiatrique, Hôpital Edouard Herriot, Lyon
| | | | | | | | | | | | | |
Collapse
|
37
|
Fireman Z, Paz D, Kopelman Y. Capsule endoscopy: improving transit time and image view. World J Gastroenterol 2005. [PMID: 16270399 DOI: 10.3748/wjg.14.2561.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/29/2022] Open
Abstract
AIM To evaluate the effect of various methods of small bowel preparation on the transit time and the quality of visualization of the entire small bowel mucosa. METHODS Ninety-five patients underwent capsule endoscopy (CE) by easily swallowing the capsule. They were divided into three study groups according to the preparation used: group A (n = 26) by polyethylene glycol (PEG) liter or with sodium phosphate (SP) 12 h prior to the CE study; group B (n = 29) by erythromycin 1 h prior to the CE study; and group C (n = 40) without any preparation. Visualization ranged from good to satisfactory to poor. RESULTS The gastric emptying time in the group prepared with erythromycin was shorter but without statistical significance and the small bowel transit time was unaffected. In elderly subjects prepared by PEG or SP, the gastric emptying time was significantly longer (163.7 min, P = 0.05). The transit times of the three sub-groups were not affected by gender or pathology. The grade of cleaning of the entire study group was 3.27+/-1.1. The erythromycin group presented significantly the worst quality of images (P = 0.05) compared to the other sub-groups. Age, gender, and pathology had no effect on the quality of the cleaning of the small bowel in the sub-groups. One (1.05%) case had no natural excretion. CONCLUSION Erythromycin markedly reduces gastric emptying time, but has a negative effect on the quality of the image in the small bowel. The preparation of elderly subjects with PEG or SP has a negative effect on the small bowel transit time.
Collapse
Affiliation(s)
- Zvi Fireman
- Department of Gastroenterology , Hillel Yaffe, Hadera, Israel.
| | | | | |
Collapse
|
38
|
Abstract
BACKGROUND Capsule endoscopy can identify lesions of the small bowel that cannot be detected by other techniques. In addition to patient safety, quality of care and cost-efficiency, good preparation is an important factor for good visualization. AIM To evaluate the efficacy of oral sodium phosphate preparation. METHODS Forty-six consecutive patients scheduled for capsule endoscopy in two medical centres. The patients treated in Dallas were prepared by 12 h fasting (group A), and those treated in Israel were also asked to drink 45 mL of sodium phosphate with water (group B). An experienced endoscopist, blinded to the method used, graded the quality of preparation according to visual capability, and to relative durations of each grade. RESULTS The quality of the preparation was poor in 35% of group A compared with 4% of group B (P = 0.023). The mean duration of good preparation with excellent visualization was 122 +/- 110 min in group A and 180 +/- 96 min in group B (P = 0.006). Preparation with sodium phosphate and lower patient weight were significant predictive factors for good visualization. CONCLUSIONS Bowel preparation offers better visualization than overnight fasting alone and is associated with fewer disturbances by intraluminal turbid fluid.
Collapse
Affiliation(s)
- Y Niv
- Department of Gastroenterology, Rabin Medical Center, Beilinson Campus, Petah Tiqva, and Sackler Faculty of Medicine, Tel Aviv University, Israel.
| | | | | | | |
Collapse
|
39
|
Abstract
AIM: To evaluate the effect of various methods of small bowel preparation on the transit time and the quality of visualization of the entire small bowel mucosa.
METHODS: Ninety-five patients underwent capsule endoscopy (CE) by easily swallowing the capsule. They were divided into three study groups according to the preparation used: group A (n = 26) by polyethylene glycol (PEG) liter or with sodium phosphate (SP) 12 h prior to the CE study; group B (n = 29) by erythromycin 1 h prior to the CE study; and group C (n = 40) without any preparation. Visualization ranged from good to satisfactory to poor.
RESULTS: The gastric emptying time in the group prepared with erythromycin was shorter but without statistical significance and the small bowel transit time was unaffected. In elderly subjects prepared by PEG or SP, the gastric emptying time was significantly longer (163.7 min, P = 0.05). The transit times of the three sub-groups were not affected by gender or pathology. The grade of cleaning of the entire study group was 3.27 ± 1.1. The erythromycin group presented significantly the worst quality of images (P = 0.05) compared to the other sub-groups. Age, gender, and pathology had no effect on the quality of the cleaning of the small bowel in the sub-groups. One (1.05%) case had no natural excretion.
CONCLUSION: Erythromycin markedly reduces gastric emptying time, but has a negative effect on the quality of the image in the small bowel. The preparation of elderly subjects with PEG or SP has a negative effect on the small bowel transit time.
Collapse
Affiliation(s)
- Zvi Fireman
- Department of Gastroenterology , Hillel Yaffe, Hadera, Israel.
| | | | | |
Collapse
|
40
|
Abstract
MR imaging, using modern equipment and a rigorous technical approach, can offer detailed morphologic information and functional data on the small bowel. The optimal study technique is debatable, although the oral administration of contrast material as a first-line approach is less expensive, faster, easier to perform, and better tolerated by patients. MR enteroclysis might be reserved for selected cases as a second-line study. The major clinical indication is the evaluation of patients who have suspected or known Crohn's disease. The absence of ionizing radiation, considering the young age of most of the patients and the frequency of the examinations, is an important advantage over other techniques (radiograph and CT enteroclysis).
Collapse
Affiliation(s)
- Andrea Laghi
- Department of Radiological Sciences, University of Rome La Sapienza, Polo Didattico Pontino - I.C.O.T., Latina, Via Franco Faggiana 34, 04100 Latina, Italy.
| | | | | |
Collapse
|
41
|
Pilleul F, Godefroy C, Yzebe-Beziat D, Dugougeat-Pilleul F, Lachaux A, Valette PJ. Magnetic resonance imaging in Crohn's disease. ACTA ACUST UNITED AC 2005; 29:803-8. [PMID: 16294149 DOI: 10.1016/s0399-8320(05)86351-1] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
AIM To evaluate the value of gadolinium enhanced MRI with oral opacification using a 5% mannitol solution (CE-Mannitol-MRI) to reveal bowel inflammation in pediatric patients with known or suspected Crohn's disease (CD). MATERIALS AND METHODS Sixty-two consecutive children (median age 13.9 years) with known or suspected CD underwent ileocolonoscopy with biopsy, ultrasonography and CE-Mannitol-MRI. CD activity was measured with the Pediatric Crohn's Disease Activity Index (PCDAI). Image quality, wall thickness, bowel wall enhancement and complications identified on CE-Mannitol-MRI were evaluated by two blinded radiologists. RESULTS The sensitivity and specificity of CE-Mannitol-MRI for the diagnosis of CD were 83% and 100%, respectively. Bowel wall enhancement was higher in the group of patients with abnormal small bowel loops versus control group (P = 0.001). In patients with known CD, there was a positive correlation between wall thickness and PCDAI (P = 0.003). However, no significant correlation was demonstrated between parietal contrast enhancement and PCDAI (P = 0.497). CE-Mannitol-MRI enabled identification of complications in 18 patients (9 fistulae, 8 strictures and 1 intussusception). CONCLUSION In pediatric patients with CD, CE-Mannitol-MRI contributes significantly to the identification of disease extension, severity and intestinal complications with adequate diagnostic accuracy. This technique could also be useful as the first line diagnostic exploration in young patients with suspected CD.
Collapse
Affiliation(s)
- Frank Pilleul
- Département d'Imagerie Digestive, Centre Hospitalo-Universitaire E. Herriot, Lyon.
| | | | | | | | | | | |
Collapse
|
42
|
Gowland PA. Present and future magnetic resonance sources of exposure to static fields. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2005; 87:175-83. [PMID: 15556657 DOI: 10.1016/j.pbiomolbio.2004.08.006] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
This paper considers the exposure of humans to static magnetic fields due to magnetic resonance imaging (MRI) procedures. It briefly introduces the types of magnetic fields associated with MRI. It then discusses trends in the number of people exposed to MRI, the field strength of the magnets used in MRI, and the types of applications of MRI. It also considers the types of staff who are exposed to magnetic fields due to MRI, and the alternative techniques that would be used in the absence of MRI.
Collapse
Affiliation(s)
- P A Gowland
- Sir Peter Mansfield Magnetic Resonance Centre, School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD UK.
| |
Collapse
|
43
|
Kastin DA, Buchman AL, Barrett T, Halverson A, Wallin A. Strictures from Crohn's disease diagnosed by video capsule endoscopy. J Clin Gastroenterol 2004; 38:346-9. [PMID: 15087694 DOI: 10.1097/00004836-200404000-00009] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Video capsule endoscopy is a new diagnostic modality that allows imaging of the entire small intestine. We report on a patient with a presumed but undocumented case of Crohn's disease who was found to have 9 ileal strictures by video capsule endoscopy. These strictures were undetected by small intestinal contrast studies and required surgical intervention. This case report suggests that small bowel radiographic studies may not be as sensitive for the detection of clinically significant luminal lesions as once thought.
Collapse
Affiliation(s)
- Darren A Kastin
- Division of Gastroenterology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | | | | | | | | |
Collapse
|
44
|
Schreyer AG, Gölder S, Seitz J, Herfarth H. New diagnostic avenues in inflammatory bowel diseases. Capsule endoscopy, magnetic resonance imaging and virtual enteroscopy. Dig Dis 2003; 21:129-37. [PMID: 14571110 DOI: 10.1159/000073244] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The modalities for diagnostic imaging in patients with inflammatory bowel disease (IBD) have dramatically changed in the last decade. Several years ago the only methods to assess the small bowel were conventional enteroclysis or a small bowel 'follow through'. Nowadays, wireless capsule endoscopy as well as magnetic resonance imaging (MRI) with virtual endoscopy represent new evolving methods to depict and assess the small bowel. This article describes these recently introduced methods in the diagnostic assessment of the small bowel and discusses the clinical significance based on the current literature.
Collapse
|
45
|
Abstract
This review focuses on the technical aspects that have allowed the development of practical bowel imaging using magnetic resonance imaging, including the acquisition methods and improvements in the underlying technology. An overview of the current techniques for small and large bowel magnetic resonance examinations is provided and the scene set for the more detailed examination of specific technical aspects such as contrast media and fecal tagging addressed in other later articles in this issue.
Collapse
Affiliation(s)
- David J Lomas
- Department of Radiology, University of Cambridge and Addenbrooke's Hospital, United Kingdom
| |
Collapse
|