1
|
Tachikawa Y, Hamano H, Chiwata N, Yoshikai H, Ikeda K, Maki Y, Takahashi Y, Koike M. Diffusion weighted imaging combining respiratory triggering and navigator echo tracking in the upper abdomen. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01150-1. [PMID: 38400926 DOI: 10.1007/s10334-024-01150-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Revised: 01/16/2024] [Accepted: 01/17/2024] [Indexed: 02/26/2024]
Abstract
OBJECTIVES To evaluate a new motion correction method, named RT + NV Track, for upper abdominal DWI that combines the respiratory triggering (RT) method using a respiration sensor and the Navigator Track (NV Track) method using navigator echoes. MATERIALS AND METHODS To evaluate image quality acquired upper abdominal DWI and ADC images with RT, NV, and RT + NV Track in 10 healthy volunteers and 35 patients, signal-to-noise efficiency (SNRefficiency) and the coefficient of variation (CV) of ADC values were measured. Five radiologists independently performed qualitative image-analysis assessments. RESULTS RT + NV Track showed significantly higher SNRefficiency than RT and NV (14.01 ± 4.86 vs 12.05 ± 4.65, 10.05 ± 3.18; p < 0.001, p < 0.001). RT + NV Track was superior to RT and equal or better quality than NV in CV and visual evaluation of ADC values (0.033 ± 0.018 vs 0.080 ± 0.042, 0.057 ± 0.034; p < 0.001, p < 0.001). RT + NV Track tends to acquire only expiratory data rather than NV, even in patients with relatively rapid breathing, and can correct for respiratory depth variations, a weakness of RT, thus minimizing image quality degradation. CONCLUSION The RT + NV Track method is an efficient imaging method that combines the advantages of both RT and NV methods in upper abdominal DWI, providing stably good images in a short scan time.
Collapse
Affiliation(s)
- Yoshihiko Tachikawa
- Division of Radiological Technology, Department of Medical Technology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan.
| | - Hiroshi Hamano
- Philips Japan, Philips Building, 2-13-37 Kohnan, Minato-ku, Tokyo, 108-8507, Japan
| | - Naoya Chiwata
- Division of Radiological Technology, Department of Medical Technology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan
| | - Hikaru Yoshikai
- Division of Radiological Technology, Department of Medical Technology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan
| | - Kento Ikeda
- Division of Radiological Technology, Department of Medical Technology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan
| | - Yasunori Maki
- Division of Radiological Technology, Department of Medical Technology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan
| | - Yukihiko Takahashi
- Department of Radiology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan
| | - Makiko Koike
- Department of Radiology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan
| |
Collapse
|
2
|
Wang L, Li T, Cai J, Chang HC. Motion-resolved four-dimensional abdominal diffusion-weighted imaging using PROPELLER EPI (4D-DW-PROPELLER-EPI). Magn Reson Med 2023; 90:2454-2471. [PMID: 37486854 DOI: 10.1002/mrm.29802] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 06/22/2023] [Accepted: 07/03/2023] [Indexed: 07/26/2023]
Abstract
PURPOSE To develop a distortion-free motion-resolved four-dimensional diffusion-weighted PROPELLER EPI (4D-DW-PROPELLER-EPI) technique for benefiting clinical abdominal radiotherapy (RT). METHODS An improved abdominal 4D-DWI technique based on 2D diffusion-weighted PROPELLER-EPI (2D-DW-PROPELLER-EPI), termed 4D-DW-PROPELLER-EPI, was proposed to improve the frame rate of repeated data acquisition and produce distortion-free 4D-DWI images. Since the radial or PROPELLER sampling with golden-angle rotation can achieve an efficient k-space coverage with a flexible time-resolved acquisition, the golden-angle multi-blade acquisition was used in the proposed 4D-DW-PROPELLER-EPI to improve the performance of data sorting. A new k-space and blade (K-B) amplitude binning method was developed for the proposed 4D-DW-PROPELLER-EPI to optimize the number of blades and the k-space uniformity before performing conventional PROPELLER-EPI reconstruction, by using two metrics to evaluate the adequacy of the acquired data. The proposed 4D-DW-PROPELLER-EPI was preliminarily evaluated in both simulation experiments and in vivo experiments with varying frame rates and different numbers of repeated acquisition. RESULTS The feasibility of achieving distortion-free 4D-DWI images by using the proposed 4D-DW-PROPELLER-EPI technique was demonstrated in both digital phantom and healthy subjects. Evaluation of the 4D completeness metrics shows that the K-B amplitude binning method could simultaneously improve the acquisition efficiency and data reconstruction performance for 4D-DW-PROPELLER-EPI. CONCLUSION 4D-DW-PROPELLER-EPI with K-B amplitude binning is an advanced technique that can provide distortion-free 4D-DWI images for resolving respiratory motion, and may benefit the application of image-guided abdominal RT.
Collapse
Affiliation(s)
- Lu Wang
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong
- Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, Hong Kong
| | - Tian Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong
| | - Hing-Chiu Chang
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong, Hong Kong
- Multi-Scale Medical Robotics Center, The Chinese University of Hong Kong, Hong Kong, Hong Kong
| |
Collapse
|
3
|
Raspe J, Harder FN, Rupp S, McTavish S, Peeters JM, Weiss K, Makowski MR, Braren RF, Karampinos DC, Van AT. Retrospective Motion Artifact Reduction by Spatial Scaling of Liver Diffusion-Weighted Images. Tomography 2023; 9:1839-1856. [PMID: 37888738 PMCID: PMC10610678 DOI: 10.3390/tomography9050146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/27/2023] [Accepted: 09/29/2023] [Indexed: 10/28/2023] Open
Abstract
Cardiac motion causes unpredictable signal loss in respiratory-triggered diffusion-weighted magnetic resonance imaging (DWI) of the liver, especially inside the left lobe. The left liver lobe may thus be frequently neglected in the clinical evaluation of liver DWI. In this work, a data-driven algorithm that relies on the statistics of the signal in the left liver lobe to mitigate the motion-induced signal loss is presented. The proposed data-driven algorithm utilizes the exclusion of severely corrupted images with subsequent spatially dependent image scaling based on a signal-loss model to correctly combine the multi-average diffusion-weighted images. The signal in the left liver lobe is restored and the liver signal is more homogeneous after applying the proposed algorithm. Furthermore, overestimation of the apparent diffusion coefficient (ADC) in the left liver lobe is reduced. The proposed algorithm can therefore contribute to reduce the motion-induced bias in DWI of the liver and help to increase the diagnostic value of DWI in the left liver lobe.
Collapse
Affiliation(s)
- Johannes Raspe
- School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany (D.C.K.); (A.T.V.)
- School of Natural Sciences, Technical University of Munich, 85748 Garching, Germany
| | - Felix N. Harder
- School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany (D.C.K.); (A.T.V.)
| | - Selina Rupp
- School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany (D.C.K.); (A.T.V.)
| | - Sean McTavish
- School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany (D.C.K.); (A.T.V.)
| | | | - Kilian Weiss
- Philips GmbH Market DACH, 22335 Hamburg, Germany
| | - Marcus R. Makowski
- School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany (D.C.K.); (A.T.V.)
| | - Rickmer F. Braren
- School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany (D.C.K.); (A.T.V.)
| | - Dimitrios C. Karampinos
- School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany (D.C.K.); (A.T.V.)
| | - Anh T. Van
- School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany (D.C.K.); (A.T.V.)
| |
Collapse
|
4
|
Zhang K, Triphan SMF, Kurz FT, Ziener CH, Kauczor HU, Schlemmer HP, Sedlaczek O. Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imaging. Magn Reson Imaging 2023; 98:26-35. [PMID: 36603781 DOI: 10.1016/j.mri.2023.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 01/01/2023] [Indexed: 01/04/2023]
Abstract
OBJECTIVES To apply a navigator-based slice tracking method to prospectively compensate the respiratory motion for kidney vessel architecture imaging (VAI). MATERIALS AND METHODS A dual gradient echo spin echo 2D EPI sequence was developed for kidney VAI. A single gradient-echo slice selection and projection readout at the location of the diaphragm along the inferior-superior direction was applied as a navigator. Navigator acquisition and fat suppression were inserted before each transverse imaging slice. Motion information was calculated after exclusion of the signal saturation in the navigator signal caused by imaging slices. The motion information was then directly sent back to the sequence and slice positioning was adjusted in real-time. The whole sequence was applied during a contrast agent pass-through. RESULTS VAI parametric maps show the structural heterogeneity of the renal vasculature. The respiratory motion from the navigator signal was precisely calculated and slice positioning was changed in real-time based on the motion information. The vibration amplitude of the signal intensity of the liver tissue at the liver-lung interface in the case of prospective motion correction (PMC) on is about 28% of the PMC off case. Compared to the case of PMC off, the coefficient of variation was reduced 30% of the case of PMC on. CONCLUSIONS This study demonstrates the feasibility of the motion-compensating technique in kidney VAI. The sequence may improve the evaluation of microvasculature in kidney diseases.
Collapse
Affiliation(s)
- Ke Zhang
- Department of Diagnostic & Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Radiology, German Cancer Research Center, Heidelberg, Germany
| | - Simon M F Triphan
- Department of Diagnostic & Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Felix T Kurz
- Department of Radiology, German Cancer Research Center, Heidelberg, Germany
| | - Christian H Ziener
- Department of Radiology, German Cancer Research Center, Heidelberg, Germany
| | - Hans-Ulrich Kauczor
- Department of Diagnostic & Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Oliver Sedlaczek
- Department of Diagnostic & Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Radiology, German Cancer Research Center, Heidelberg, Germany.
| |
Collapse
|
5
|
Obara M, Kwon J, Yoneyama M, Ueda Y, Cauteren MV. Technical Advancements in Abdominal Diffusion-weighted Imaging. Magn Reson Med Sci 2023; 22:191-208. [PMID: 36928124 PMCID: PMC10086402 DOI: 10.2463/mrms.rev.2022-0107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023] Open
Abstract
Since its first observation in the 18th century, the diffusion phenomenon has been actively studied by many researchers. Diffusion-weighted imaging (DWI) is a technique to probe the diffusion of water molecules and create a MR image with contrast based on the local diffusion properties. The DWI pixel intensity is modulated by the hindrance the diffusing water molecules experience. This hindrance is caused by structures in the tissue and reflects the state of the tissue. This characteristic makes DWI a unique and effective tool to gain more insight into the tissue's pathophysiological condition. In the past decades, DWI has made dramatic technical progress, leading to greater acceptance in clinical practice. In the abdominal region, however, acquiring DWI with good quality is challenging because of several reasons, such as large imaging volume, respiratory and other types of motion, and difficulty in achieving homogeneous fat suppression. In this review, we discuss technical advancements from the past decades that help mitigate these problems common in abdominal imaging. We describe the use of scan acceleration techniques such as parallel imaging and compressed sensing to reduce image distortion in echo planar imaging. Then we compare techniques developed to mitigate issues due to respiratory motion, such as free-breathing, respiratory-triggering, and navigator-based approaches. Commonly used fat suppression techniques are also introduced, and their effectiveness is discussed. Additionally, the influence of the abovementioned techniques on image quality is demonstrated. Finally, we discuss the current and future clinical applications of abdominal DWI, such as whole-body DWI, simultaneous multiple-slice excitation, intravoxel incoherent motion, and the use of artificial intelligence. Abdominal DWI has the potential to develop further in the future, thanks to scan acceleration and image quality improvement driven by technological advancements. The accumulation of clinical proof will further drive clinical acceptance.
Collapse
Affiliation(s)
| | | | | | - Yu Ueda
- MR Clinical Science, Philips Japan Ltd
| | | |
Collapse
|
6
|
Son JS, Park HS, Park S, Kim YJ, Yu MH, Jung SI, Paek M, Nickel MD. Motion-Corrected versus Conventional Diffusion-Weighted Magnetic Resonance Imaging of the Liver Using Non-Rigid Registration. Diagnostics (Basel) 2023; 13:diagnostics13061008. [PMID: 36980314 PMCID: PMC10047344 DOI: 10.3390/diagnostics13061008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 03/01/2023] [Accepted: 03/04/2023] [Indexed: 03/09/2023] Open
Abstract
It is challenging to overcome motion artifacts in diffusion-weighted imaging (DWI) of the abdomen. This study aimed to evaluate the image quality of motion-corrected DWI of the liver using non-rigid registration in comparison with conventional DWI (c-DWI) in patients with liver diseases. Eighty-nine patients who underwent 3-T magnetic resonance imaging (MRI) of the liver were retrospectively included. DWI was performed using c-DWI and non-rigid motion-corrected (moco) DWI was performed in addition to c-DWI. The image quality and conspicuity of hepatic focal lesions were scored using a five-point scale by two radiologists and compared between the two DWI image sets. The apparent diffusion coefficient (ADC) was measured in three regions of the liver parenchyma and in hepatic focal lesions, and compared between the two DWI image sets. Moco-DWI achieved higher scores in image quality compared to c-DWI in terms of liver edge sharpness and hepatic vessel margin delineation. The conspicuity scores of hepatic focal lesions were higher in moco-DWI. The standard deviation values of ADC of the liver parenchyma were lower in the moco-DWI than in the c-DWI. Moco-DWI using non-rigid registration showed improved overall image quality and provided more reliable ADC measurement, with an equivalent scan time, compared with c-DWI.
Collapse
Affiliation(s)
- Je Seung Son
- Department of Radiology, Konkuk University Medical Center, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
| | - Hee Sun Park
- Department of Radiology, Konkuk University Medical Center, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
- Department of Radiology, Konkuk University School of Medicine, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
- Correspondence: ; Tel.: +82-2-2030-5497; Fax: +82-2-2030-7748
| | - Sungeun Park
- Department of Radiology, Konkuk University Medical Center, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
| | - Young Jun Kim
- Department of Radiology, Konkuk University Medical Center, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
- Department of Radiology, Konkuk University School of Medicine, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
| | - Mi Hye Yu
- Department of Radiology, Konkuk University Medical Center, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
- Department of Radiology, Konkuk University School of Medicine, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
| | - Sung Il Jung
- Department of Radiology, Konkuk University Medical Center, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
- Department of Radiology, Konkuk University School of Medicine, 120-1, Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
| | - Munyoung Paek
- Department of Diagnostic Imaging, Siemens Healthineers Ltd., The Asset Bldg. 10F, 14 Seocho-Daero 74-gil, Seocho-gu, Seoul 06620, Republic of Korea
| | - Marcel Dominik Nickel
- MR Application Predevelopment, Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052 Erlangen, Germany
| |
Collapse
|
7
|
McTavish S, Van AT, Peeters JM, Weiss K, Makowski MR, Braren RF, Karampinos DC. Motion compensated renal diffusion weighted imaging. Magn Reson Med 2022; 89:144-160. [PMID: 36098347 DOI: 10.1002/mrm.29433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 07/15/2022] [Accepted: 08/10/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE To assess the effect of respiratory motion and cardiac driven pulsation in renal DWI and to examine asymmetrical velocity-compensated diffusion encoding waveforms for robust ADC mapping in the kidneys. METHODS The standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) and the asymmetric bipolar velocity-compensated (asym-vc) diffusion encoding waveforms were used for coronal renal DWI at 3T. The robustness of the ADC quantification in the kidneys was tested with the aforementioned waveforms in respiratory-triggered and breath-held cardiac-triggered scans at different trigger delays in 10 healthy subjects. RESULTS The pgse waveform showed higher ADC values in the right kidney at short trigger delays in comparison to longer trigger delays in the respiratory triggered scans when the diffusion gradient was applied in the feet-head (FH) direction. The coefficient of variation over all respiratory trigger delays, averaged over all subjects was 0.15 for the pgse waveform in the right kidney when diffusion was measured in the FH direction; the corresponding coefficient of variation for the asym-vc waveform was 0.06. The effect of cardiac driven pulsation was found to be small in comparison to the effect of respiratory motion. CONCLUSION Short trigger delays in respiratory-triggered scans can cause higher ADC values in comparison to longer trigger delays in renal DWI, especially in the right kidney when diffusion is measured in the FH direction. The asym-vc waveform can reduce ADC variation due to respiratory motion in respiratory-triggered scans at the cost of reduced SNR compared to the pgse waveform.
Collapse
Affiliation(s)
- Sean McTavish
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| | - Anh T Van
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| | | | | | - Marcus R Makowski
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| | - Rickmer F Braren
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| | - Dimitrios C Karampinos
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| |
Collapse
|
8
|
Bae SH, Hwang J, Hong SS, Lee EJ, Jeong J, Benkert T, Sung J, Arberet S. Clinical feasibility of accelerated diffusion weighted imaging of the abdomen with deep learning reconstruction: Comparison with conventional diffusion weighted imaging. Eur J Radiol 2022; 154:110428. [DOI: 10.1016/j.ejrad.2022.110428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 06/23/2022] [Accepted: 06/27/2022] [Indexed: 01/03/2023]
|
9
|
Liang X, Bi Z, Yang C, Sheng R, Xia X, Zhang Z, Dai Y, Zeng M. Free-Breathing Liver Magnetic Resonance Imaging With Respiratory Frequency-Modulated Continuous-Wave Radar-Trigger Technique: A Preliminary Study. Front Oncol 2022; 12:918173. [PMID: 35719930 PMCID: PMC9200370 DOI: 10.3389/fonc.2022.918173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 05/03/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose The aim of this study is to evaluate the performance of free-breathing liver MRI with a novel respiratory frequency-modulated continuous-wave radar-trigger (FT) technique on T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) for both healthy volunteers and patients in comparison to navigator-trigger (NT) and belt-trigger (BT) techniques. Methods In this prospective study, 17 healthy volunteers and 23 patients with known or suspected liver diseases were enrolled. Six sequences (T2WI and DWI with FT, NT, and BT techniques) were performed in each subject. Quantitative evaluation and qualitative assessment were analyzed by two radiologists. Overall image quality, blurring, motion artifacts, and liver edge delineations were rated on a 4-point Likert scale. The liver and lesion signal-to-noise ratio (SNR), the lesion-to-liver contrast-to-noise ratio (CNR), as well as the apparent diffusion coefficient (ADC) value were quantitatively calculated. Results For volunteers, there were no significant differences in the image quality Likert scores and quantitative parameters on T2WI and DWI with three respiratory-trigger techniques. For patients, NT was superior to other techniques for image quality on T2WI; conversely, little difference was found on DWI in qualitative assessment. The mean SNR of the liver on T2WI and DWI with BT, NT, and FT techniques was similar in patients, which is in line with volunteers. FT performed better in terms of higher SNR (705.13 ± 434.80) and higher CNR (504.41 ± 400.69) on DWI at b50 compared with BT (SNR: 651.83 ± 401.16; CNR:429.24 ± 404.11) and NT (SNR: 639.41 ± 407.98; CNR: 420.64 ± 416.61) (p < 0.05). The mean ADC values of the liver and lesion with different techniques in both volunteers and patients showed non-significant difference. Conclusion For volunteers, the performance of T2WI as well as DWI with three respiratory-trigger techniques was similarly good. As for patients, FT-DWI is superior to BT and NT techniques in terms of higher lesion SNR and CNR at b50.
Collapse
Affiliation(s)
- Xinyue Liang
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Zhenghong Bi
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Chun Yang
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Ruofan Sheng
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xinyuan Xia
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Zheng Zhang
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Yongming Dai
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Mengsu Zeng
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
10
|
Laun FB, Führes T, Seuss H, Müller A, Bickelhaupt S, Stemmer A, Benkert T, Uder M, Saake M. Flow-compensated diffusion encoding in MRI for improved liver metastasis detection. PLoS One 2022; 17:e0268843. [PMID: 35617260 PMCID: PMC9135229 DOI: 10.1371/journal.pone.0268843] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 05/09/2022] [Indexed: 12/27/2022] Open
Abstract
Magnetic resonance (MR) diffusion-weighted imaging (DWI) is often used to detect focal liver lesions (FLLs), though DWI image quality can be limited in the left liver lobe owing to the pulsatile motion of the nearby heart. Flow-compensated (FloCo) diffusion encoding has been shown to reduce this pulsation artifact. The purpose of this prospective study was to intra-individually compare DWI of the liver acquired with conventional monopolar and FloCo diffusion encoding for assessing metastatic FLLs in non-cirrhotic patients. Forty patients with known or suspected multiple metastatic FLLs were included and measured at 1.5 T field strength with a conventional (monopolar) and a FloCo diffusion encoding EPI sequence (single refocused; b-values, 50 and 800 s/mm2). Two board-certified radiologists analyzed the DWI images independently. They issued Likert-scale ratings (1 = worst, 5 = best) for pulsation artifact severity and counted the difference of lesions visible at b = 800 s/mm² separately for small and large FLLs (i.e., < 1 cm or > 1 cm) and separately for left and right liver lobe. Differences between the two diffusion encodings were assessed with the Wilcoxon signed-rank test. Both readers found a reduction in pulsation artifact in the liver with FloCo encoding (p < 0.001 for both liver lobes). More small lesions were detected with FloCo diffusion encoding in both liver lobes (left lobe: six and seven additional lesions by readers 1 and 2, respectively; right lobe: five and seven additional lesions for readers 1 and 2, respectively). Both readers found one additional large lesion in the left liver lobe. Thus, flow-compensated diffusion encoding appears more effective than monopolar diffusion encoding for the detection of liver metastases.
Collapse
Affiliation(s)
- Frederik B. Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Tobit Führes
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Hannes Seuss
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
- Department of Radiology, Klinikum Forchheim—Fränkische Schweiz gGmbH, Forchheim, Germany
| | - Astrid Müller
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Sebastian Bickelhaupt
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | | | | | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Marc Saake
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
- * E-mail:
| |
Collapse
|
11
|
McTavish S, Van AT, Peeters JM, Weiss K, Makowski MR, Braren RF, Karampinos DC. Gradient nonlinearity correction in liver DWI using motion-compensated diffusion encoding waveforms. MAGMA (NEW YORK, N.Y.) 2022; 35:827-841. [PMID: 34894335 PMCID: PMC9463296 DOI: 10.1007/s10334-021-00981-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 11/25/2021] [Accepted: 11/26/2021] [Indexed: 12/29/2022]
Abstract
OBJECTIVE : To experimentally characterize the effectiveness of a gradient nonlinearity correction method in removing ADC bias for different motion-compensated diffusion encoding waveforms. METHODS The diffusion encoding waveforms used were the standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) waveform, the symmetric bipolar velocity-compensated waveform (sym-vc), the asymmetric bipolar velocity-compensated waveform (asym-vc) and the asymmetric bipolar partial velocity-compensated waveform (asym-pvc). The effectiveness of the gradient nonlinearity correction method using the spherical harmonic expansion of the gradient coil field was tested with the aforementioned waveforms in a phantom and in four healthy subjects. RESULTS The gradient nonlinearity correction method reduced the ADC bias in the phantom experiments for all used waveforms. The range of the ADC values over a distance of ± 67.2 mm from isocenter reduced from 1.29 × 10-4 to 0.32 × 10-4 mm2/s for pgse, 1.04 × 10-4 to 0.22 × 10-4 mm2/s for sym-vc, 1.22 × 10-4 to 0.24 × 10-4 mm2/s for asym-vc and 1.07 × 10-4 to 0.11 × 10-4 mm2/s for asym-pvc. The in vivo results showed that ADC overestimation due to motion or bright vessels can be increased even further by the gradient nonlinearity correction. CONCLUSION The investigated gradient nonlinearity correction method can be used effectively with various motion-compensated diffusion encoding waveforms. In coronal liver DWI, ADC errors caused by motion and residual vessel signal can be increased even further by the gradient nonlinearity correction.
Collapse
Affiliation(s)
- Sean McTavish
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Anh T. Van
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | | | - Marcus R. Makowski
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Rickmer F. Braren
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Dimitrios C. Karampinos
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| |
Collapse
|
12
|
Hernando D, Zhang Y, Pirasteh A. Quantitative diffusion MRI of the abdomen and pelvis. Med Phys 2021; 49:2774-2793. [PMID: 34554579 DOI: 10.1002/mp.15246] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 08/05/2021] [Accepted: 09/15/2021] [Indexed: 12/14/2022] Open
Abstract
Diffusion MRI has enormous potential and utility in the evaluation of various abdominal and pelvic disease processes including cancer and noncancer imaging of the liver, prostate, and other organs. Quantitative diffusion MRI is based on acquisitions with multiple diffusion encodings followed by quantitative mapping of diffusion parameters that are sensitive to tissue microstructure. Compared to qualitative diffusion-weighted MRI, quantitative diffusion MRI can improve standardization of tissue characterization as needed for disease detection, staging, and treatment monitoring. However, similar to many other quantitative MRI methods, diffusion MRI faces multiple challenges including acquisition artifacts, signal modeling limitations, and biological variability. In abdominal and pelvic diffusion MRI, technical acquisition challenges include physiologic motion (respiratory, peristaltic, and pulsatile), image distortions, and low signal-to-noise ratio. If unaddressed, these challenges lead to poor technical performance (bias and precision) and clinical outcomes of quantitative diffusion MRI. Emerging and novel technical developments seek to address these challenges and may enable reliable quantitative diffusion MRI of the abdomen and pelvis. Through systematic validation in phantoms, volunteers, and patients, including multicenter studies to assess reproducibility, these emerging techniques may finally demonstrate the potential of quantitative diffusion MRI for abdominal and pelvic imaging applications.
Collapse
Affiliation(s)
- Diego Hernando
- Departments of Radiology and Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Yuxin Zhang
- Departments of Radiology and Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Ali Pirasteh
- Departments of Radiology and Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
13
|
Saake M, Seuß H, Riexinger A, Bickelhaupt S, Hammon M, Uder M, Laun FB. Image Quality and Detection of Small Focal Liver Lesions in Diffusion-Weighted Imaging: Comparison of Navigator Tracking and Free-Breathing Acquisition. Invest Radiol 2021; 56:579-590. [PMID: 33813572 DOI: 10.1097/rli.0000000000000776] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVES The aim of this study was to compare intraindividual diffusion-weighted imaging (DWI) of the liver acquired with free breathing (FB) versus navigator triggering (NT) for assessing small focal liver lesions (FLLs) in noncirrhotic patients. MATERIALS AND METHODS Patients with known or suspected multiple FLLs were prospectively included, and spin-echo echo-planar DWI with NT and FB acquisition was performed (b-values, 50 and 800 s/mm2 [b50 and b800]). NT and FB DWI sequences with similar acquisitions times were used. Liver and lesion signal-to-noise ratios were measured at b800. The DWI scans were analyzed independently by 2 readers. Liver edge delineation, presence of stair-step artifacts, vessel sharpness, severity of cardiac motion artifacts, overall image quality, and lesion conspicuity were rated with 5-point Likert scales. Small and large FLLs (ie, <1 cm or ≥1 cm) were rated separately for lesion conspicuity. The FLL detectability was estimated by comparing the number of lesions visible with FB to those visible with NT. RESULTS Forty-three patients were included in the study. The FB acquisition performed better in terms of severity of cardiac motion artifacts. The NT performed better in terms of liver edge delineation and vessel sharpness. Little difference was found for stair-step artifact, overall image quality, and conspicuity of large FLL, whereas the conspicuity of small FLL was better for NT. For small FLL, both readers found more lesions with NT in 11 cases at b800. For large FLL, this effect was much less pronounced (1 case at b800 reported by 1 of the readers). The mean liver and lesion signal-to-noise ratios were 16.8/41.5 and 19.8/38.4 for NT/FB, respectively. CONCLUSIONS Small FLL detection is better with NT. Large FLL detection by FB and NT is similarly good. We conclude that NT should be used.
Collapse
Affiliation(s)
- Marc Saake
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | | | - Andreas Riexinger
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | - Sebastian Bickelhaupt
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | - Matthias Hammon
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | - Michael Uder
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | - Frederik B Laun
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| |
Collapse
|
14
|
Effects of different breathing techniques on the IVIM-derived quantitative parameters of the normal pancreas. Eur J Radiol 2021; 143:109892. [PMID: 34388419 DOI: 10.1016/j.ejrad.2021.109892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 07/29/2021] [Accepted: 07/30/2021] [Indexed: 11/21/2022]
Abstract
PURPOSE To prospectively compare the differences in intravoxel incoherent motion (IVIM)-derived quantitative parameters in different anatomic locations of the normal pancreas with different breathing techniques in a healthy population. METHOD Twenty-six volunteers successfully underwent pancreas axial IVIM imaging with a 3.0-T MR system using 11 b-values (from 0 to 1000 sec/mm2) with three different breathing techniques: free breath (FB), liver dome scout (LDS), and phase scout (PS). The IVIM-derived quantitative parameters in three anatomic locations (head, body, and tail of the pancreas) were calculated. The intra-, inter-, and short-term consistency of IVIM-derived quantitative parameters were assessed by comparing 95% confidence interval (CI) of limits of agreement (LOA) of difference between measurements and clinical maximum allowed difference using the Bland-Altman method. The Kruskal-Wallis test was used to compare pancreatic IVIM-derived parameters. RESULTS In Bland-Altman graph, the maximum values of the 95% CIs of LOAs of Dslow, Dfast, and f were (0.123 ± 0.022) × 10-3 mm2/sec, (22.093 ± 4.997) × 10-3 mm2/sec, and (3.942 ± 0.621)%, and the consistency of Dslow and f was good and that of Dfast was poor overall. The Dslow, Dfast, and f values of normal pancreas were (1.056 ± 0.121) × 10-3 mm2/sec, (55.755 ± 13.011) × 10-3 mm2/sec, and (26.036 ± 2.361)%, respectively, and there aren't any breathing technique (P > 0.05) or location (P > 0.05) dependent differences. CONCLUSIONS Our study shows that IVIM-derived quantitative parameters of the pancreas may not be affected by breathing techniques and anatomic locations. The f and Dslow values have good repeated measurement consistency under different breathing techniques.
Collapse
|
15
|
Stocker D, Hectors S, Bane O, Vietti-Violi N, Said D, Kennedy P, Cuevas J, Cunha GM, Sirlin CB, Fowler KJ, Lewis S, Taouli B. Dynamic contrast-enhanced MRI perfusion quantification in hepatocellular carcinoma: comparison of gadoxetate disodium and gadobenate dimeglumine. Eur Radiol 2021; 31:9306-9315. [PMID: 34043055 DOI: 10.1007/s00330-021-08068-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 04/22/2021] [Accepted: 05/11/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVES (1) To assess the quality of the arterial input function (AIF) during dynamic contrast-enhanced (DCE) MRI of the liver and (2) to quantify perfusion parameters of hepatocellular carcinoma (HCC) and liver parenchyma during the first 3 min post-contrast injection with DCE-MRI using gadoxetate disodium compared to gadobenate dimeglumine (Gd-BOPTA) in different patient populations. METHODS In this prospective study, we evaluated 66 patients with 83 HCCs who underwent DCE-MRI, using gadoxetate disodium (group 1, n = 28) or Gd-BOPTA (group 2, n = 38). AIF qualitative and quantitative features were assessed. Perfusion parameters (based on the initial 3 min post-contrast) were extracted in tumours and liver parenchyma, including model-free parameters (time-to-peak enhancement (TTP), time-to-washout) and modelled parameters (arterial flow (Fa), portal venous flow (Fp), total flow (Ft), arterial fraction, mean transit time (MTT), distribution volume (DV)). In addition, lesion-to-liver contrast ratios (LLCRs) were measured. Fisher's exact tests and Mann-Whitney U tests were used to compare the two groups. RESULTS AIF quality, modelled and model-free perfusion parameters in HCC were similar between the 2 groups (p = 0.054-0.932). Liver parenchymal flow was lower and liver enhancement occurred later in group 1 vs group 2 (Fp, p = 0.002; Ft, p = 0.001; TTP, MTT, all p < 0.001), while there were no significant differences in tumour LLCR (max. positive LLCR, p = 0.230; max. negative LLCR, p = 0.317). CONCLUSION Gadoxetate disodium provides comparable AIF quality and HCC perfusion parameters compared to Gd-BOPTA during dynamic phases. Despite delayed and decreased liver enhancement with gadoxetate disodium, LLCRs were equivalent between contrast agents, indicating similar tumour conspicuity. KEY POINTS • Arterial input function quality, modelled, and model-free dynamic parameters measured in hepatocellular carcinoma are similar in patients receiving gadoxetate disodium or gadobenate dimeglumine during the first 3 min post injection. • Gadoxetate disodium and gadobenate dimeglumine show similar lesion-to-liver contrast ratios during dynamic phases in patients with HCC. • There is lower portal and lower total hepatic flow and longer hepatic mean transit time and time-to-peak with gadoxetate disodium compared to gadobenate dimeglumine.
Collapse
Affiliation(s)
- Daniel Stocker
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Institute of Diagnostic and Interventional Radiology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Stefanie Hectors
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY, 10029, USA
| | - Octavia Bane
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY, 10029, USA
| | - Naik Vietti-Violi
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Daniela Said
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Radiology, Universidad de los Andes, Santiago, Chile
| | - Paul Kennedy
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY, 10029, USA
| | - Jordan Cuevas
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY, 10029, USA
| | - Guilherme M Cunha
- Liver Imaging Group, Radiology, University of California-San Diego, San Diego, CA, USA
| | - Claude B Sirlin
- Liver Imaging Group, Radiology, University of California-San Diego, San Diego, CA, USA
| | - Kathryn J Fowler
- Liver Imaging Group, Radiology, University of California-San Diego, San Diego, CA, USA
| | - Sara Lewis
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY, 10029, USA
| | - Bachir Taouli
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA. .,Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY, 10029, USA.
| |
Collapse
|
16
|
Ladrova M, Martinek R, Nedoma J, Hanzlikova P, Nelson MD, Kahankova R, Brablik J, Kolarik J. Monitoring and Synchronization of Cardiac and Respiratory Traces in Magnetic Resonance Imaging: A Review. IEEE Rev Biomed Eng 2021; 15:200-221. [PMID: 33513108 DOI: 10.1109/rbme.2021.3055550] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Synchronization of human vital signs, namely the cardiac cycle and respiratory excursions, is necessary during magnetic resonance imaging of the cardiovascular system and the abdominal cavity to achieve optimal image quality with minimized artifacts. This review summarizes techniques currently available in clinical practice, as well as methods under development, outlines the benefits and disadvantages of each approach, and offers some unique solutions for consideration.
Collapse
|
17
|
Xie S, Masokano IB, Liu W, Long X, Li G, Pei Y, Li W. Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla. Eur J Radiol 2020; 135:109472. [PMID: 33370640 DOI: 10.1016/j.ejrad.2020.109472] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 11/26/2020] [Accepted: 12/08/2020] [Indexed: 01/09/2023]
Abstract
PURPOSE To compare the clinical utility of single-shot echo-planar imaging (SS-EPI) using different breathing schemes and readout-segmented EPI (RS-EPI) in the repeatability of apparent diffusion coefficient (ADC) measurements, signal-to-noise ratio (SNR) and image quality. METHODS In this institutional review board-approved prospective study, hepatic DWIs (b = 50, 300, 600 s/mm2) were performed in 22 volunteers on 3.0 T MRI using SS-EPI with free-breathing diffusion-weighted imaging (FB-DWI), breath-hold (BH-DWI), respiratory-triggered (RT-DWI) and navigator-triggered (NT-DWI), and readout-segmented EPI (RS-DWI). ADC and surrogate SNR (sSNR) were measured in nine anatomic locations in the right lobe, and image quality was assessed on all FB-DWI, BH-DWI, RT-DWI, NT-DWI, and RS-DWI sequences. The sequence with the optimal clinical utility was decided by systematically comparing the ADC repeatability, sSNR and image quality of the above DWIs. RESULTS In all the five sequences, NT-DWI had the most reliable intra-observer agreement (intraclass correlation coefficient (ICC): 0.900-0.922; all P > 0.05), and a better interobserver agreement (ICC: 0.853-0.960; all p > 0.05) than RS-DWI (ICC:0.881-0.916; some P < 0.05). NT-DWI had the best ADC repeatability in the nine locations (mean ADC absolute differences: 38.47-56.38 × 10-6 mm2/s, limits of agreement (LOA): 17.33-22.52 × 10-6 mm2/s). Also, NT-DWI had the highest sSNR (Reader 1: 50.58 ± 20.11 (Superior), 74.06 ± 28.37 (Central), 80.99 ± 38.11(Inferior)); Reader 2: 48.07 ± 23.92 (Superior), 68.23 ± 32.91 (Central), 76.78 ± 33.07 (Inferior)) in three representative sections except for RS-DWI. Furthermore, NT-DWI had a better image quality than RS-DWI (P < 0.05) and was superior to FB-DWI and BH-DWI in sharpness of the liver (at b = 300 s/mm2) (P < 0.05) CONCLUSION: RS-DWI has the best SNR. However, NT-DWI can provide sufficient SNR, excellent image quality, and the best ADC repeatability on 3.0 T MRI. It is thus the recommended sequence for the clinical application of hepatic DWI.
Collapse
Affiliation(s)
- Simin Xie
- Department of Radiology, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, China
| | - Ismail Bilal Masokano
- Department of Radiology, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, China
| | - Wenguang Liu
- Department of Radiology, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, China
| | - Xueying Long
- Department of Radiology, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, China
| | - Guijin Li
- Siemens Healthcare Ltd, Guangzhou Branch, 510620, China
| | - Yigang Pei
- Department of Radiology, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, China; Postdoctoral Fellow, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, China.
| | - Wenzheng Li
- Department of Radiology, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, China.
| |
Collapse
|
18
|
Riexinger A, Laun FB, Bickelhaupt S, Seuß H, Uder M, Hensel B, Saake M. On the dependence of the cardiac motion artifact on the breathing cycle in liver diffusion-weighted imaging. PLoS One 2020; 15:e0239743. [PMID: 33002028 PMCID: PMC7529231 DOI: 10.1371/journal.pone.0239743] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Accepted: 09/11/2020] [Indexed: 12/17/2022] Open
Abstract
Purpose The purpose of this study was to investigate whether the cardiac motion artifact that regularly appears in diffusion-weighted imaging of the left liver lobe might be reduced by acquiring images in inspiration, when the coupling between heart and liver might be minimal. Materials and methods 43 patients with known or suspected focal liver lesions were examined at 1.5 T with breath hold acquisition, once in inspiration and once in expiration. Data were acquired with a diffusion-weighted echo planar imaging sequence and two b-values (b50 = 50 s/mm² and b800 = 800 s/mm²). The severity of the cardiac motion artifact in the left liver lobe was rated by two experienced radiologists for both b-values with a 5 point Likert scale. Additionally, the normalized signal S(b800)/S(b50) in the left liver lobe was computed. The Wilcoxon signed-rank test was used comparing the scores of the two readers obtained in inspiration and expiration, and to compare the normalized signal in inspiration and expiration. Results The normalized signal in inspiration was slightly higher than in expiration (0.349±0.077 vs 0.336±0.058), which would indicate a slight reduction of the cardiac motion artifact, but this difference was not significant (p = 0.24). In the qualitative evaluation, the readers did not observe a significant difference for b50 (reader 1: p = 0.61; reader 2: p = 0.18). For b800, reader 1 observed a significant difference of small effect size favouring expiration (p = 0.03 with a difference of mean Likert scores of 0.27), while reader 2 observed no significant difference (p = 0.62). Conclusion Acquiring the data in inspiration does not lead to a markedly reduced cardiac motion artifact in diffusion-weighted imaging of the left liver lobe and is in this regard not to be preferred over acquiring the data in expiration.
Collapse
Affiliation(s)
- Andreas Riexinger
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
- * E-mail:
| | | | | | - Hannes Seuß
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
| | - Bernhard Hensel
- Center for Medical Physics and Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Marc Saake
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
19
|
Rauh SS, Riexinger AJ, Ohlmeyer S, Hammon M, Saake M, Stemmer A, Uder M, Hensel B, Laun FB. A mixed waveform protocol for reduction of the cardiac motion artifact in black-blood diffusion-weighted imaging of the liver. Magn Reson Imaging 2020; 67:59-68. [PMID: 31923466 DOI: 10.1016/j.mri.2019.12.011] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 12/11/2019] [Accepted: 12/31/2019] [Indexed: 02/06/2023]
Abstract
OBJECTIVE Diffusion-weighted imaging (DWI) in the liver suffers from signal loss due to the cardiac motion artifact, especially in the left liver lobe. The purpose of this work was to improve the image quality of liver DWI in terms of cardiac motion artifact reduction and achievement of black-blood images in low b-value images. MATERIAL AND METHODS Ten healthy volunteers (age 20-31 years) underwent MRI examinations at 1.5 T with a prototype DWI sequence provided by the vendor. Two diffusion encodings (i.e. waveforms), monopolar and flow-compensated, and the b-values 0, 20, 50, 100, 150, 600 and 800 s/mm2 were used. Two Likert scales describing the severity of the pulsation artifact and the quality of the black-blood state were defined and evaluated by two experienced radiologists. Regions of interest (ROIs) were manually drawn in the right and left liver lobe in each slice and combined to a volume of interest (VOI). The mean and coefficient of variation were calculated for each normalized VOI-averaged signal to assess the severity of the cardiac motion artifact. The ADC was calculated using two b-values once for the monopolar data and once with mixed data, using the monopolar data for the small and the flow-compensated data for the high b-value. A Wilcoxon rank sum test was used to compare the Likert scores obtained for monopolar and flow-compensated data. RESULTS At b-values from 20 to 150 s/mm2, unlike the flow-compensated diffusion encoding, the monopolar encoding yielded black blood in all images with a negligible signal loss due to the cardiac motion artifact. At the b-values 600 and 800 s/mm2, the flow-compensated encoding resulted in a significantly reduced cardiac motion artifact, especially in the left liver lobe, and in a black-blood state. The ADC calculated with monopolar data was significantly higher in the left than in the right liver lobe. CONCLUSION It is recommendable to use the following mixed waveform protocol: Monopolar diffusion encodings at small b-values and flow-compensated diffusion encodings at high b-values.
Collapse
Affiliation(s)
- Susanne S Rauh
- Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | - Andreas J Riexinger
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Sabine Ohlmeyer
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Matthias Hammon
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Marc Saake
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | | | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Bernhard Hensel
- Center for Medical Physics and Engineering, Friedrich-Alexander-Universität Erlangen-, Nürnberg, (FAU), Erlangen, Germany
| | - Frederik B Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| |
Collapse
|
20
|
Szklaruk J, Son JB, Wei W, Bhosale P, Javadi S, Ma J. Comparison of free breathing and respiratory triggered diffusion-weighted imaging sequences for liver imaging. World J Radiol 2019; 11:134-143. [PMID: 31798795 PMCID: PMC6885723 DOI: 10.4329/wjr.v11.i11.134] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 08/26/2019] [Accepted: 09/26/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Diffusion-weighted imaging (DWI) has become a useful tool in the detection, characterization, and evaluation of response to treatment of many cancers, including malignant liver lesions. DWI offers higher image contrast between lesions and normal liver tissue than other sequences. DWI images acquired at two or more b-values can be used to derive an apparent diffusion coefficient (ADC). DWI in the body has several technical challenges. This include ghosting artifacts, mis-registration and susceptibility artifacts. New DWI sequences have been developed to overcome some of these challenges. Our goal is to evaluate 3 new DWI sequences for liver imaging.
AIM To qualitatively and quantitatively compare 3 DWI sequences for liver imaging: free-breathing (FB), simultaneous multislice (SMS), and prospective acquisition correction (PACE).
METHODS Magnetic resonance imaging (MRI) was performed in 20 patients in this prospective study. The MR study included 3 separate DWI sequences: FB-DWI, SMS-DWI, and PACE-DWI. The image quality, mean ADC, standard deviations (SD) of ADC, and ADC histogram were compared. Wilcoxon signed-rank tests were used to compare qualitative image quality. A linear mixed model was used to compare the mean ADC and the SDs of the ADC values. All tests were 2-sided and P values of < 0.05 were considered statistically significant.
RESULTS There were 56 lesions (50 malignant) evaluated in this study. The mean qualitative image quality score of PACE-DWI was 4.48. This was significantly better than that of SMS-DWI (4.22) and FB-DWI (3.15) (P < 0.05). Quantitatively, the mean ADC values from the 3 different sequences did not significantly differ for each liver lesion. FB-DWI had a markedly higher variation in the SD of the ADC values than did SMS-DWI and PACE-DWI. We found statistically significant differences in the SDs of the ADC values for FB-DWI vs PACE-DWI (P < 0.0001) and for FB-DWI vs SMS-DWI (P = 0.03). The SD of the ADC values was not statistically significant for PACE-DWI and SMS-DWI (P = 0.18). The quality of the PACE-DWI ADC histograms were considered better than the SMS-DWI and FB-DWI.
CONCLUSION Compared to FB-DWI, both PACE-DWI and SMS-DWI provide better image quality and decreased quantitative variability in the measurement of ADC values of liver lesions.
Collapse
Affiliation(s)
- Janio Szklaruk
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Jong Bum Son
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Wei Wei
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Priya Bhosale
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Sanaz Javadi
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Jingfei Ma
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| |
Collapse
|
21
|
Luo J, Zhou K, Zhang B, Luo N, Bian J. Intravoxel Incoherent Motion Diffusion-Weighted Imaging for Evaluation of the Cell Density and Angiogenesis of Cirrhosis-Related Nodules in an Experimental Rat Model: Comparison and Correlation With Dynamic Contrast-Enhanced MRI. J Magn Reson Imaging 2019; 51:812-823. [PMID: 31245888 PMCID: PMC7027506 DOI: 10.1002/jmri.26845] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 06/11/2019] [Accepted: 06/12/2019] [Indexed: 12/12/2022] Open
Abstract
Background Intravoxel incoherent motion diffusion‐weighted imaging (IVIM‐DWI) and dynamic contrast‐enhanced MRI (DCE‐MRI) are sensitive imaging modalities for detecting liver lesions, but their value in evaluating cirrhosis‐related nodules remains unclear. Purpose To investigate whether IVIM‐DWI and DCE‐MRI can differentiate different types of cirrhosis‐related nodules, and whether these modalities can monitor changes in cell density and angiogenesis during the malignant transformation of cirrhosis‐related nodules in a rat model Study Type Prospective. Animal Model Thirty‐five male Sprague–Dawley rats with 106 cirrhosis‐related nodules (19 regenerative nodules [RNs], 47 dysplastic nodules [DNs], and 40 hepatocellular carcinomas [HCCs]). Field Strength/Sequence IVIM‐DWI and DCE sequence at 3.0T MRI. Assessment IVIM‐DWI parameters (D, D*, f, and apparent diffusion coefficient [ADC]) and DCE‐MRI parameters (Ktrans, Kep, and Ve) were calculated by two radiologists using postprocessing software. The “cell density” and “unpaired arterial ratio” were analyzed with a microscope by two pathologists. Statistical Tests MRI parameters were compared among the different types of nodules by one‐way analysis of variance or the Kruskal–Wallis test. The Pearson correlation test was used to analyze the correlation of MRI parameters with the pathological types of nodules, cell density, and unpaired arterial ratio. Results The Ktrans, Kep, and Ve values of HCCs were significantly higher than those of DNs and RNs. D and ADC values were significantly lower in HCCs than in DNs and RNs. There were moderate positive correlations of Ktrans with the pathological types of nodules and the unpaired arterial ratio. Moderate negative correlations were observed among D, ADC, and the pathological types of nodules, between D and cell density, and between ADC and cell density. Data Conclusion IVIM‐DWI and DCE‐MRI are valuable in differentiating different types of cirrhotic‐related nodules. D and ADC are correlated with changes in cell density during the malignant transformation of cirrhosis‐related nodules, while Ktrans is correlated with increased angiogenesis. Level of Evidence: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:812–823.
Collapse
Affiliation(s)
- Jiawen Luo
- Department of Radiology, Second Hospital of Dalian Medical University, Dalian, P.R. China
| | - Kunpeng Zhou
- Department of Radiology, Second Hospital of Dalian Medical University, Dalian, P.R. China
| | - Bin Zhang
- School of Biomedical Engineering Dalian University of Technology, Dalian, P.R. China
| | - Ning Luo
- Department of Radiology, Second Hospital of Dalian Medical University, Dalian, P.R. China
| | - Jie Bian
- Department of Radiology, Second Hospital of Dalian Medical University, Dalian, P.R. China
| |
Collapse
|
22
|
Considering tumour volume for motion corrected DWI of colorectal liver metastases increases sensitivity of ADC to detect treatment-induced changes. Sci Rep 2019; 9:3828. [PMID: 30846790 PMCID: PMC6405765 DOI: 10.1038/s41598-019-40565-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Accepted: 02/12/2019] [Indexed: 01/20/2023] Open
Abstract
ADC is a potential post treatment imaging biomarker in colorectal liver metastasis however measurements are affected by respiratory motion. This is compounded by increased statistical uncertainty in ADC measurement with decreasing tumour volume. In this prospective study we applied a retrospective motion correction method to improve the image quality of 15 tumour data sets from 11 patients. We compared repeatability of ADC measurements corrected for motion artefact against non-motion corrected acquisition of the same data set. We then applied an error model that estimated the uncertainty in ADC repeatability measurements therefore taking into consideration tumour volume. Test-retest differences in ADC for each tumour, was scaled to their estimated measurement uncertainty, and 95% confidence limits were calculated, with a null hypothesis that there is no difference between the model distribution and the data. An early post treatment scan (within 7 days of starting treatment) was acquired for 12 tumours from 8 patients. When accounting for both motion artefact and statistical uncertainty due to tumour volumes, the threshold for detecting significant post treatment changes for an individual tumour in this data set, reduced from 30.3% to 1.7% (95% limits of agreement). Applying these constraints, a significant change in ADC (5th and 20th percentiles of the ADC histogram) was observed in 5 patients post treatment. For smaller studies, motion correcting data for small tumour volumes increased statistical efficiency to detect post treatment changes in ADC. Lower percentiles may be more sensitive than mean ADC for colorectal metastases.
Collapse
|
23
|
Comparison of Navigator Triggering Reduced Field of View and Large Field of View Diffusion-Weighted Imaging of the Pancreas. J Comput Assist Tomogr 2019; 43:143-148. [PMID: 30119065 DOI: 10.1097/rct.0000000000000778] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
RATIONALE AND OBJECTIVES The purpose of this study is to compare image quality, presence and grade of artifacts, signal-to-noise ratio, and apparent diffusion coefficient (ADC) values in pancreatic tissue between high-resolution navigator-triggered (NT) restricted field of view (rFOV) FOCUS single-shot (SS) echo-planar imaging (EPI) diffusion-weighted imaging (DWI) and NT large FOV SS-EPI DWI. MATERIALS AND METHODS Magnetic resonance imaging examinations were performed with GE 3-T systems using a 32-channel body array coil. Seventeen consecutive patients were imaged. A 5-point scale semiquantitative grading system was used to evaluate image quality and general artifacts. Signal-to-noise ratio and ADC were measured in the head, body, and tail of the pancreas. Statistical analysis was performed using Student t test and Wilcoxon signed rank test, with differences considered significant for P value less than 0.05. RESULTS More artifacts were present on large FOV compared with rFOV FOCUS SS-EPI DW images (P < 0.01). Restricted field of view image quality was subjectively better (P < 0.01). No difference in the signal-to-noise ratio was demonstrated between the 2 image datasets. Apparent diffusion coefficient values were significantly lower (P < 0.01) when calculated from rFOV images than large FOV images. CONCLUSIONS Our results demonstrate better image quality and reduced artifacts in rFOV images compared with large FOV DWI. Measurements from ADC maps derived from rFOV DWI show significantly lower ADC values when compared with ADC maps derived from large FOV DWI.
Collapse
|
24
|
Schmeel FC. Variability in quantitative diffusion-weighted MR imaging (DWI) across different scanners and imaging sites: is there a potential consensus that can help reducing the limits of expected bias? Eur Radiol 2018; 29:2243-2245. [PMID: 30488105 DOI: 10.1007/s00330-018-5866-4] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Accepted: 10/25/2018] [Indexed: 12/16/2022]
Abstract
KEY POINTS • Variability of ADC measurements may be substantial across different MRI scanners and imaging sites. • DWI protocol standardization and increased awareness of frequent sources of error can help reducing the limits of expected bias. • Focusing on ADC change and normalized ADC values rather than on absolute measurements can facilitate consistent use of ADC in multi-center studies.
Collapse
Affiliation(s)
- Frederic Carsten Schmeel
- Department of Radiology, University Hospital Bonn, Rheinische-Friedrich-Wilhelms-Universität Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Germany.
| |
Collapse
|
25
|
Khorram FS, Faeghi F, Jafarisepehr A, Farshidfar Z. Evaluation of Respiratory Triggered Diffusion-Weighted MRI with Three b-Values Compared to ADC Map and Fast Spin Echo Heavily T2W in Differential Diagnosis of Hemangioma from Malignant Liver Lesions. J Med Imaging Radiat Sci 2018; 49:251-256. [DOI: 10.1016/j.jmir.2018.04.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 02/22/2018] [Accepted: 04/11/2018] [Indexed: 10/14/2022]
|
26
|
Ebraheem Ebeed A, Abd El-hamied Romeih M, Mohamed Refat M, Hamdy Yossef M. Role of dynamic contrast-enhanced and diffusion weighted MRI in evaluation of hepatocellular carcinoma after chemoembolization. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2017. [DOI: 10.1016/j.ejrnm.2017.06.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
|
27
|
Abstract
Renal cell carcinoma (RCC) exhibits a diverse and heterogeneous disease spectrum, but insight into its molecular biology has provided an improved understanding of potential risk factors, oncologic behavior, and imaging features. Computed tomography (CT) and MR imaging may allow the identification and preoperative subtyping of RCC and assessment of a response to various therapies. Active surveillance is a viable management option in some patients and has provided further insight into the natural history of RCC, including the favorable prognosis of cystic neoplasms. This article reviews CT and MR imaging in RCC and the role of screening in selected high-risk populations.
Collapse
Affiliation(s)
- Alberto Diaz de Leon
- Department of Radiology, University of Texas Southwestern Medical Center, 2201 Inwood Road, 2nd Floor, Suite 202, Dallas, TX 75390-9085, USA
| | - Ivan Pedrosa
- Department of Radiology, University of Texas Southwestern Medical Center, 2201 Inwood Road, 2nd Floor, Suite 202, Dallas, TX 75390-9085, USA.
| |
Collapse
|
28
|
Pathak R, Ragheb H, Thacker NA, Morris DM, Amiri H, Kuijer J, deSouza NM, Heerschap A, Jackson A. A data-driven statistical model that estimates measurement uncertainty improves interpretation of ADC reproducibility: a multi-site study of liver metastases. Sci Rep 2017; 7:14084. [PMID: 29075009 PMCID: PMC5658431 DOI: 10.1038/s41598-017-14625-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Accepted: 10/09/2017] [Indexed: 02/06/2023] Open
Abstract
Apparent Diffusion Coefficient (ADC) is a potential quantitative imaging biomarker for tumour cell density and is widely used to detect early treatment changes in cancer therapy. We propose a strategy to improve confidence in the interpretation of measured changes in ADC using a data-driven model that describes sources of measurement error. Observed ADC is then standardised against this estimation of uncertainty for any given measurement. 20 patients were recruited prospectively and equitably across 4 sites, and scanned twice (test-retest) within 7 days. Repeatability measurements of defined regions (ROIs) of tumour and normal tissue were quantified as percentage change in mean ADC (test vs. re-test) and then standardised against an estimation of uncertainty. Multi-site reproducibility, (quantified as width of the 95% confidence bound between the lower confidence interval and higher confidence interval for all repeatability measurements), was compared before and after standardisation to the model. The 95% confidence interval width used to determine a statistically significant change reduced from 21.1 to 2.7% after standardisation. Small tumour volumes and respiratory motion were found to be important contributors to poor reproducibility. A look up chart has been provided for investigators who would like to estimate uncertainty from statistical error on individual ADC measurements.
Collapse
Affiliation(s)
- Ryan Pathak
- University of Manchester, Wolfson Molecular Imaging Centre, Manchester, UK.
| | - Hossein Ragheb
- University of Manchester, Wolfson Molecular Imaging Centre, Manchester, UK
| | - Neil A Thacker
- University of Manchester, Wolfson Molecular Imaging Centre, Manchester, UK
| | - David M Morris
- University of Manchester, Wolfson Molecular Imaging Centre, Manchester, UK
| | - Houshang Amiri
- Radboudumc, Radiology and Nuclear Medicine, Nijmegen, Gelderland, NL, Netherlands
- Neuroscience Research Center, Institute of Neuropharmacology, Kerman University of Medical Sciences, Kerman, Iran
| | - Joost Kuijer
- VU University Medical Center, Physics & Medical Technology, PO Box 7057, Amsterdam, NL, 1007MB, Netherlands
| | - Nandita M deSouza
- Institute of Cancer Research, MRI Unit, Downs Road, Sutton, Surrey, SM2 5PT, UK
| | - Arend Heerschap
- Radboudumc, Radiology and Nuclear Medicine, Nijmegen, Gelderland, NL, Netherlands
| | - Alan Jackson
- University of Manchester, Wolfson Molecular Imaging Centre, Manchester, UK
| |
Collapse
|
29
|
Takayama Y, Nishie A, Asayama Y, Ishigami K, Kakihara D, Ushijima Y, Fujita N, Shirabe K, Takemura A, Honda H. Image quality and diagnostic performance of free-breathing diffusion-weighted imaging for hepatocellular carcinoma. World J Hepatol 2017; 9:657-666. [PMID: 28588750 PMCID: PMC5437610 DOI: 10.4254/wjh.v9.i14.657] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2016] [Revised: 02/11/2017] [Accepted: 04/24/2017] [Indexed: 02/06/2023] Open
Abstract
AIM To retrospectively evaluate the diagnostic performance of free-breathing diffusion-weighted imaging (FB-DWI) with modified imaging parameter settings for detecting hepatocellular carcinomas (HCCs).
METHODS Fifty-one patients at risk for HCC were scanned with both FB-DWI and respiratory-triggered DWI with the navigator echo respiratory-triggering technique (RT-DWI). Qualitatively, the sharpness of the liver contour, the image noise and the chemical shift artifacts on each DWI with b-values of 1000 s/mm2 were independently evaluated by three radiologists using 4-point scoring. We compared the image quality scores of each observer between the two DWI methods, using the Wilcoxon signed-rank test. Quantitatively, we compared the signal-to-noise ratios (SNRs) of the liver parenchyma and lesion-to-nonlesion contrast-to-noise ratios (CNRs) after measuring the signal intensity on each DWI with a b-factor of 1000 s/mm2. The average SNRs and CNRs between the two DWI methods were compared by the paired t-test. The detectability of HCC on each DWI was also analyzed by three radiologists. The detectability provided by the two DWI methods was compared using McNemar’s test.
RESULTS For all observers, the averaged image quality scores of FB-DWI were: Sharpness of the liver contour [observer (Obs)-1, 3.08 ± 0.81; Obs-2, 2.98 ± 0.73; Obs-3, 3.54 ± 0.75], those of the distortion (Obs-1, 2.94 ± 0.50; Obs-2, 2.71 ± 0.70; Obs-3, 3.27 ± 0.53), and the chemical shift artifacts (Obs-1, 3.38 ± 0.60; Obs-2, 3.15 ± 1.07; Obs-3, 3.21 ± 0.85). The averaged image quality scores of RT-DWI were: Sharpness of the liver contour (Obs-1, 2.33 ± 0.65; Obs-2, 2.37 ± 0.74; Obs-3, 2.75 ± 0.81), distortion (Obs-1, 2.81 ± 0.56; Obs-2, 2.25 ± 0.74; Obs-3, 2.96 ± 0.71), and the chemical shift artifacts (Obs-1, 2.92 ± 0.59; Obs-2, 2.21 ± 0.85; Obs-3, 2.77 ± 1.08). All image quality scores of FB-DWI were significantly higher than those of RT-DWI (P < 0.05). The average SNR of the normal liver parenchyma by FB-DWI (11.0 ± 4.8) was not significantly different from that shown by RT-DWI (11.0 ± 5.0); nor were the lesion-to-nonlesion CNRs significantly different (FB-DWI, 21.4 ± 17.7; RT-DWI, 20.1 ± 15.1). For all three observers, the detectability of FB-DWI (Obs-1, 43.6%; Obs-2, 53.6%; and Obs-3, 45.0%) was significantly higher than that of RT-DWI (Obs-1, 29.1%; Obs-2, 43.6%; and Obs-3, 34.5%) (P < 0.05).
CONCLUSION FB-DWI showed better image quality and higher detectability of HCC compared to RT-DWI, without significantly reducing the SNRs of the liver parenchyma and lesion-to-nonlesion CNRs.
Collapse
|
30
|
Motion-robust parameter estimation in abdominal diffusion-weighted MRI by simultaneous image registration and model estimation. Med Image Anal 2017; 39:124-132. [PMID: 28494271 DOI: 10.1016/j.media.2017.04.006] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 04/07/2017] [Accepted: 04/22/2017] [Indexed: 01/22/2023]
Abstract
Quantitative body DW-MRI can detect abdominal abnormalities as well as monitor response-to-therapy for applications including cancer and inflammatory bowel disease with increased accuracy. Parameter estimates are obtained by fitting a forward model of DW-MRI signal decay to the observed data acquired with several b-values. The DW-MRI signal decay models typically used do not account for respiratory, cardiac and peristaltic motion, however, which may deteriorate the accuracy and robustness of parameter estimates. In this work, we introduce a new model of DW-MRI signal decay that explicitly accounts for motion. Specifically, we estimated motion-compensated model parameters by simultaneously solving image registration and model estimation (SIR-ME) problems utilizing the interdependence of acquired volumes along the diffusion-weighting dimension. To accomplish this, we applied the SIR-ME model to the in-vivo DW-MRI data sets of 26 Crohn's disease (CD) patients and achieved improved precision of the estimated parameters by reducing the coefficient of variation by 8%, 24% and 8% for slow diffusion (D), fast diffusion (D*) and fast diffusion fraction (f) parameters respectively, compared to parameters estimated with independent registration in normal-appearing bowel regions. Moreover, the parameters estimated with the SIR-ME model reduced the error rate in classifying normal and abnormal bowel loops to 12% for D and 10% for f parameter with a reduction in error rate by 13% and 11% for D and f parameters, respectively, compared to the error rate in classifying parameter estimates obtained with independent registration. The experiments in DW-MRI of liver in 20 subjects also showed that the SIR-ME model improved the precision of parameter estimation by reducing the coefficient of variation to 7% for D, 23% for D*, and 8% for the f parameter. Using the SIR-ME model, the coefficient of variation was reduced by 4%, 14% and 6% for D, D* and f parameters, respectively, compared to parameters estimated with independent registration. These results demonstrate that the proposed SIR-ME model improves the accuracy and robustness of quantitative body DW-MRI in characterizing tissue microstructure.
Collapse
|
31
|
Wieder H, Beer AJ, Holzapfel K, Henninger M, Maurer T, Schwarzenboeck S, Rummeny EJ, Eiber M, Stollfuss J. 11C-choline PET/CT and whole-body MRI including diffusion-weighted imaging for patients with recurrent prostate cancer. Oncotarget 2017; 8:66516-66527. [PMID: 29029532 PMCID: PMC5630432 DOI: 10.18632/oncotarget.16227] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2016] [Accepted: 03/06/2017] [Indexed: 12/13/2022] Open
Abstract
Purpose To compare the detection efficacy of 11C-choline positron emission tomography and computed tomography (PET/CT) with whole-body magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI) in patients with suspected recurrent prostate cancer. Materials and Methods Fifty-seven patients (mean age 68, range 54-80 years) underwent 11C-choline PET/CT and MRI using T1-weighted (T1w), short-tau inversion recovery (STIR), and DWI. Two readers visually rated suspicious lesions on a 5-point scale in 20 different regions. Clinical follow-up and histopathology served as the standard of reference (SOR). Results Fifty patients (mean PSA 29.9, range 1.0-670 ng/mL) had at least one positive lesion according to the SOR. Twenty-four patients had local recurrence (LR), 27 had lymph node (LN) involvement, and 22 had bone metastases. The overall detection rates for PET/CT and MRI on a patient basis were 94% and 88%, respectively (p = 0.07). The PSA level (>2 ng/mL vs ≤2 ng/mL) significantly influenced the overall performance of PET/CT (p = 0.003) and MRI (p = 0.03). PET/CT was significantly superior to MRI in detecting LR (p = 0.03) and bone metastasis (p = 0.02). We found no difference with respect to the detection of LN metastasis (p = 0.65). Conclusion 11C-choline PET/CT was superior in the detection of local recurrence and bone metastasis on a regional basis. Whole-body MRI including DWI showed similar diagnostic accuracy only for detecting lymph node metastases. Compared with 11C-choline PET/CT, therefore, whole-body MRI including DWI cannot serve as alternative imaging modality for restaging prostate cancer.
Collapse
Affiliation(s)
- Hinrich Wieder
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München, Munich, Germany.,Centre for Radiology and Nuclear Medicine, Grevenbroich, Germany
| | - Ambros J Beer
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München, Munich, Germany.,Department of Nuclear Medicine, Ulm University, Ulm, Germany
| | - Konstantin Holzapfel
- Institute for Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Martin Henninger
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Tobias Maurer
- Department of Urology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | | | - Ernst J Rummeny
- Institute for Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Matthias Eiber
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Jens Stollfuss
- Institute for Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany.,Department of Radiology and Nuclear Medicine, Klinikum Memmingen, Memmingen, Germany
| |
Collapse
|
32
|
Diffusion-weighted MRI in liver fibrosis staging: Added value of normalized ADC using spleen and renal cortex as reference organs. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2017. [DOI: 10.1016/j.ejrnm.2016.11.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
|
33
|
Tsuchiya N, Doai M, Usuda K, Uramoto H, Tonami H. Non-small cell lung cancer: Whole-lesion histogram analysis of the apparent diffusion coefficient for assessment of tumor grade, lymphovascular invasion and pleural invasion. PLoS One 2017; 12:e0172433. [PMID: 28207858 PMCID: PMC5313135 DOI: 10.1371/journal.pone.0172433] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2016] [Accepted: 02/04/2017] [Indexed: 12/30/2022] Open
Abstract
PURPOSE Investigating the diagnostic accuracy of histogram analyses of apparent diffusion coefficient (ADC) values for determining non-small cell lung cancer (NSCLC) tumor grades, lymphovascular invasion, and pleural invasion. MATERIALS AND METHODS We studied 60 surgically diagnosed NSCLC patients. Diffusion-weighted imaging (DWI) was performed in the axial plane using a navigator-triggered single-shot, echo-planar imaging sequence with prospective acquisition correction. The ADC maps were generated, and we placed a volume-of-interest on the tumor to construct the whole-lesion histogram. Using the histogram, we calculated the mean, 5th, 10th, 25th, 50th, 75th, 90th, and 95th percentiles of ADC, skewness, and kurtosis. Histogram parameters were correlated with tumor grade, lymphovascular invasion, and pleural invasion. We performed a receiver operating characteristics (ROC) analysis to assess the diagnostic performance of histogram parameters for distinguishing different pathologic features. RESULTS The ADC mean, 10th, 25th, 50th, 75th, 90th, and 95th percentiles showed significant differences among the tumor grades. The ADC mean, 25th, 50th, 75th, 90th, and 95th percentiles were significant histogram parameters between high- and low-grade tumors. The ROC analysis between high- and low-grade tumors showed that the 95th percentile ADC achieved the highest area under curve (AUC) at 0.74. Lymphovascular invasion was associated with the ADC mean, 50th, 75th, 90th, and 95th percentiles, skewness, and kurtosis. Kurtosis achieved the highest AUC at 0.809. Pleural invasion was only associated with skewness, with the AUC of 0.648. CONCLUSIONS ADC histogram analyses on the basis of the entire tumor volume are able to stratify NSCLCs' tumor grade, lymphovascular invasion and pleural invasion.
Collapse
Affiliation(s)
- Naoko Tsuchiya
- Department of Radiology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Mariko Doai
- Department of Radiology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Katsuo Usuda
- Department of Thoracic Surgery, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Hidetaka Uramoto
- Department of Thoracic Surgery, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Hisao Tonami
- Department of Radiology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
- * E-mail:
| |
Collapse
|
34
|
Loeffler RB, McCarville MB, Wagstaff AW, Smeltzer MP, Krafft AJ, Song R, Hankins JS, Hillenbrand CM. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification? Pediatr Radiol 2017; 47:46-54. [PMID: 27752732 PMCID: PMC5203961 DOI: 10.1007/s00247-016-3700-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Revised: 07/21/2016] [Accepted: 08/26/2016] [Indexed: 11/25/2022]
Abstract
BACKGROUND Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. OBJECTIVE To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. MATERIALS AND METHODS This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. RESULTS Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. CONCLUSION We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be interchangeably used in existing R2*-HIC calibrations.
Collapse
Affiliation(s)
- Ralf B Loeffler
- Diagnostic Imaging, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678, USA
| | - M Beth McCarville
- Diagnostic Imaging, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678, USA
| | - Anne W Wagstaff
- Diagnostic Imaging, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678, USA
- Rhodes College, Memphis, TN, USA
- University of Alabama at Birmingham School of Medicine, Birmingham, AL, USA
| | - Matthew P Smeltzer
- Department of Biostatistics, St. Jude Children's Research Hospital, Memphis, TN, USA
- Division of Epidemiology, Biostatistics, and Environmental Health, School of Public Health, University of Memphis, Memphis, TN, USA
| | - Axel J Krafft
- Diagnostic Imaging, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678, USA
- Department of Radiology, University Hospital Center Freiburg, Freiburg, Germany
| | - Ruitian Song
- Diagnostic Imaging, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678, USA
| | - Jane S Hankins
- Department of Hematology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Claudia M Hillenbrand
- Diagnostic Imaging, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678, USA.
| |
Collapse
|
35
|
Abstract
PURPOSE The purpose of the study was to identify the frequency and reasons for extra sequences in clinical liver MRI and MRCP examinations. METHODS A total of 250 consecutive liver MRI and 250 consecutive MRCP examinations performed at a single institution were reviewed. Extra sequences performed in comparison with our standard institutional protocol were identified. Reasons for the extra sequences were identified. Overall trends were assessed. RESULTS In significantly greater fractions of exams (p = 0.009-0.030), MRCP had ≥1 extra sequence (40.8% vs. 29.2%) and ≥2 extra sequences (16.0% vs. 5.6%) in comparison with the institutional protocol than did liver MRI. The average number of extra sequences was significantly higher (p = 0.004) for MRCP (0.73 ± 1.2) than liver MRI (0.44 ± 0.88). Reasons for extra sequences were as follows: sequence repeated for patient motion (33.8% for liver MRI; 31.9% for MRCP); sequence repeated for anatomic coverage (24.3% for liver MRI; 19.8% for MRCP); sequence added by the radiologist (15.3% for liver MRI; 33.0% for MRCP); sequence repeated for other reason (17.1% for liver MRI; 12.6% for MRCP); and sequence added by the technologist (5.4% for liver MRI; 2.7% for MRCP). The most commonly repeated sequence due to motion was the axial fat-saturated turbo spin-echo T2-weighted sequence for both liver MRI and MRCP (54.7% and 29.3% of sequences repeated due to motion, respectively). CONCLUSION For liver MRI and MRCP exams, sequences were most often repeated due to motion artifact (most often occurring on TSE T2WI), and sequences were most often added by the radiologist. The findings may help guide sequence optimization, quality improvement initiatives, and standardization of operations, for improving efficiency in abdominal MRI workflow.
Collapse
|
36
|
Talaat Ali M, Fouad Osman M, Homos MD, Mohamed Nabil D. Role of 3-T diffusion-weighted magnetic resonance imaging in differentiation between benign and malignant hepatic lesions. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2016. [DOI: 10.1016/j.ejrnm.2016.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
37
|
Saito K, Tajima Y, Harada TL. Diffusion-weighted imaging of the liver: Current applications. World J Radiol 2016; 8:857-867. [PMID: 27928467 PMCID: PMC5120245 DOI: 10.4329/wjr.v8.i11.857] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Revised: 08/10/2016] [Accepted: 10/24/2016] [Indexed: 02/06/2023] Open
Abstract
Diffusion-weighted imaging (DWI) of the liver can be performed using most commercially available machines and is currently accepted in routine sequence. This sequence has some potential as an imaging biomarker for fibrosis, tumor detection/characterization, and following/predicting therapy. To improve reliability including accuracy and reproducibility, researchers have validated this new technique in terms of image acquisition, data sampling, and analysis. The added value of DWI in contrast-enhanced magnetic resonance imaging was established in the detection of malignant liver lesions. However, some limitations remain in terms of lesion characterization and fibrosis detection. Furthermore, the methodologies of image acquisition and data analysis have been inconsistent. Therefore, researchers should make every effort to not only improve accuracy and reproducibility but also standardize imaging parameters.
Collapse
|
38
|
Karaosmanoglu AD, Onur MR, Ozmen MN, Akata D, Karcaaltincaba M. Magnetic Resonance Imaging of Liver Metastasis. Semin Ultrasound CT MR 2016; 37:533-548. [PMID: 27986172 DOI: 10.1053/j.sult.2016.08.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Liver magnetic resonance imaging (MRI) is becoming the gold standard in liver metastasis detection and treatment response assessment. The most sensitive magnetic resonance sequences are diffusion-weighted images and hepatobiliary phase images after Gd-EOB-DTPA. Peripheral ring enhancement, diffusion restriction, and hypointensity on hepatobiliary phase images are hallmarks of liver metastases. In patients with normal ultrasonography, computed tomography (CT), and positron emission tomography (PET)-CT findings and high clinical suspicion of metastasis, MRI should be performed for diagnosis of unseen metastasis. In melanoma, colon cancer, and neuroendocrine tumor metastases, MRI allows confident diagnosis of treatment-related changes in liver and enables differential diagnosis from primary liver tumors. Focal nodular hyperplasia-like nodules in patients who received platinum-based chemotherapy, hypersteatosis, and focal fat can mimic metastasis. In cancer patients with fatty liver, MRI should be preferred to CT. Although the first-line imaging for metastases is CT, MRI can be used as a problem-solving method. MRI may be used as the first-line method in patients who would undergo curative surgery or metastatectomy. Current limitation of MRI is low sensitivity for metastasis smaller than 3mm. MRI fingerprinting, glucoCEST MRI, and PET-MRI may allow simpler and more sensitive diagnosis of liver metastasis.
Collapse
Affiliation(s)
- Ali Devrim Karaosmanoglu
- Liver Imaging Team, Department of Radiology, School of Medicine, Hacettepe University, Ankara, Turkey
| | - Mehmet Ruhi Onur
- Liver Imaging Team, Department of Radiology, School of Medicine, Hacettepe University, Ankara, Turkey
| | - Mustafa Nasuh Ozmen
- Liver Imaging Team, Department of Radiology, School of Medicine, Hacettepe University, Ankara, Turkey
| | - Deniz Akata
- Liver Imaging Team, Department of Radiology, School of Medicine, Hacettepe University, Ankara, Turkey
| | - Musturay Karcaaltincaba
- Liver Imaging Team, Department of Radiology, School of Medicine, Hacettepe University, Ankara, Turkey.
| |
Collapse
|
39
|
Diffusion-weighted imaging of hepatocellular carcinomas: a retrospective analysis of correlation between apparent diffusion coefficients and histological grade. Abdom Radiol (NY) 2016; 41:1539-45. [PMID: 27003574 DOI: 10.1007/s00261-016-0715-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
PURPOSE To define correlations between the pathological grades of hepatocellular carcinomas (HCCs) and apparent diffusion coefficients (ADCs) derived using breath-holding diffusion-weighted imaging (BH-DWI). METHODS We retrospectively evaluated 94 patients (105 lesions) with pathologically proved HCC who underwent hepatic DWI on a 3.0-T MR platform. HCCs were divided into five groups: well-differentiated (n = 10), well-to-moderately differentiated (n = 11), moderately differentiated (n = 51), moderately to poorly differentiated (n = 20), and poorly differentiated (n = 13) groups. The ADCs of carcinomas across different histological grades were compared by one-way analysis of variance. Spearman's rank correlation test was used to analyze correlations between the degree of histopathological differentiation and ADC. Results were corrected for multiple comparisons using the Bonferroni correction. RESULTS The BH technique yielded ADC values that differed significantly by the extent of differentiation (F = 8.392, p < 0.001). A significant negative correlation was found between the extent of differentiation and ADCs (r = -0.462, p < 0.001). The mean ADC values of poorly differentiated HCCs were significantly lower than the well-, well-to-moderately, moderately, and moderately to poorly differentiated HCCs (p values were <0.001, <0.001, 0.003, and 0.031, respectively). CONCLUSION ADC values obtained with BH-DWI may be of importance to non-invasively predict HCC tumor differentiation, and the extent of histological HCC differentiation was inversely correlated with ADC values.
Collapse
|
40
|
Nakamura Y, Higaki T, Akiyama Y, Fukumoto W, Kajiwara K, Kaichi Y, Honda Y, Komoto D, Tatsugami F, Iida M, Ohmoto T, Date S, Awai K. Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging. Eur J Radiol Open 2016; 3:138-44. [PMID: 27489867 PMCID: PMC4959945 DOI: 10.1016/j.ejro.2016.07.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 06/30/2016] [Accepted: 07/02/2016] [Indexed: 12/16/2022] Open
Abstract
Purpose To investigate the utility of computed 3T diffusion-weighted imaging (c-DWI) for the diagnosis of non-complicated hepatic cysts with a focus on the T2 shine-through effect. Materials and methods In 50 patients with non-complicated hepatic cysts we acquired one set of DWIs (b-value 0 and 1000 s/mm2) at 1.5T, and two sets at 3T (b-value 0 and 1000 s/mm2, TE 70 ms; b-value 0 and 600 s/mm2, TE 60 ms). We defined the original DWIs acquired with b = 1000 s/mm2 at 1.5T and 3T as “o-1.5T-1000” and “o-3T-1000”. c-DWIs were calculated with 3T DWI at b-values of 0 and 600 s/mm2. c-DWI with b = 1000 and 1500 s/mm2 were defined as “c-1000” and “c-1500”. Radiologists evaluated the signal intensity (SI) of the cysts using a 3-point score where 1 = not visible, 2 = discernible, and 3 = clearly visible. They calculated the contrast ratio (CR) between the cysts and the surrounding liver parenchyma on each DWIs and recorded the apparent diffusion coefficient (ADC) with a b-value = 0 and 1000 s/mm2 on 1.5T- and 3T DWIs. Results Compared with o-1.5T-1000 DWI, the visual scores of all but the c-1500 DWIs were higher (p = 0.07 for c-1500- and p < 0.01 for the other DWIs). The CR at b = 1000 s/mm2 was higher on o-3T-1000- than on o-1.5T-1000- (p < 0.01) but not higher than on c-1500 DWIs (p = 0.96). The CR at b = 0 s/mm2 on 3T images with TE 70 ms was higher than on 1.5T images (p < 0.01). The ADC value was higher for 3T- than 1.5T images (p < 0.01). Conclusions Non-complicated hepatic cysts showed higher SI on o-3T-1000- than o-1.5T-1000 DWIs due to the T2-shine through effect. This high SI was suppressed on c-1500 DWIs.
Collapse
Key Words
- ADC, apparent diffusion coefficient
- CR, contrast ratio
- Computed diffusion-weighted imaging
- DWI, diffusion-weighted imaging
- Diffusion-weighted imaging
- Field strength
- HCC, hepatocellular carcinoma
- MRI, magnetic resonance imaging
- Non-complicated hepatic cysts
- SI, signal intensity
- SNR, signal-to-noise ratio
- T1-WI, T1-weighted MRI
- T2 shine-through effect
- T2-WI, T2-weighted MRI
- c-DWI, computed diffusion-weighted imaging
Collapse
Affiliation(s)
- Yuko Nakamura
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Toru Higaki
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Yuji Akiyama
- Department of Radiology, Hiroshima University Hospital, Hiroshima, Japan
| | - Wataru Fukumoto
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Kenji Kajiwara
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Yoko Kaichi
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Yukiko Honda
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Daisuke Komoto
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | | | - Makoto Iida
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | | | - Shuji Date
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Kazuo Awai
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
41
|
Dohan A, Taylor S, Hoeffel C, Barret M, Allez M, Dautry R, Zappa M, Savoye-Collet C, Dray X, Boudiaf M, Reinhold C, Soyer P. Diffusion-weighted MRI in Crohn's disease: Current status and recommendations. J Magn Reson Imaging 2016; 44:1381-1396. [PMID: 27249184 DOI: 10.1002/jmri.25325] [Citation(s) in RCA: 68] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Accepted: 05/12/2016] [Indexed: 12/19/2022] Open
Abstract
Over the past years, technological improvements and refinements in magnetic resonance imaging (MRI) hardware have made high-quality diffusion-weighted imaging (DWI) routinely possible for the bowel. DWI is promising for the detection and characterization of lesions in Crohn's disease (CD) and has been advocated as an alternative to intravenous gadolinium-based contrast agents. Furthermore, quantification using the apparent diffusion coefficient may have value as a biomarker of CD activity and has shown promise. In this article we critically review the literature pertaining to the value of DWI in CD for detection, characterization, and quantification of disease activity and complications. Although the body of supportive evidence is growing, it is clear that well-designed, multicenter studies are required before the role of DWI in clinical practice can be fully established. J. Magn. Reson. Imaging 2016;44:1381-1396.
Collapse
Affiliation(s)
- Anthony Dohan
- McGill University Health Center, Department of Radiology, McGill University Health Center, Montreal, QC, Canada
- Department of Body and Interventional Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris, France
- Université Paris-Diderot, Sorbonne Paris Cité, Paris, France
- INSERM UMR 965, Paris, France
| | - Stuart Taylor
- Centre for Medical Imaging, University College London, Podium Level 2, University College Hospital, London, UK
| | | | - Maximilien Barret
- Department of Gastroenterology, Hôpital Cochin, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Matthieu Allez
- Université Paris-Diderot, Sorbonne Paris Cité, Paris, France
- Department of Gastroenterology, Hôpital Saint-Louis, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Raphael Dautry
- Department of Body and Interventional Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Magaly Zappa
- Department of Radiology, Hôpital Beaujon, Assistance Publique-Hôpitaux de Paris, Clichy, France
| | | | - Xavier Dray
- Université Paris-Diderot, Sorbonne Paris Cité, Paris, France
- Department of Gastroenterology, Hôpital Saint-Antoine, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Mourad Boudiaf
- Department of Body and Interventional Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Caroline Reinhold
- McGill University Health Center, Department of Radiology, McGill University Health Center, Montreal, QC, Canada
| | - Philippe Soyer
- Department of Body and Interventional Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris, France
- Université Paris-Diderot, Sorbonne Paris Cité, Paris, France
- INSERM UMR 965, Paris, France
| |
Collapse
|
42
|
Iima M, Le Bihan D. Clinical Intravoxel Incoherent Motion and Diffusion MR Imaging: Past, Present, and Future. Radiology 2016; 278:13-32. [PMID: 26690990 DOI: 10.1148/radiol.2015150244] [Citation(s) in RCA: 346] [Impact Index Per Article: 43.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The concept of diffusion magnetic resonance (MR) imaging emerged in the mid-1980s, together with the first images of water diffusion in the human brain, as a way to probe tissue structure at a microscopic scale, although the images were acquired at a millimetric scale. Since then, diffusion MR imaging has become a pillar of modern clinical imaging. Diffusion MR imaging has mainly been used to investigate neurologic disorders. A dramatic application of diffusion MR imaging has been acute brain ischemia, providing patients with the opportunity to receive suitable treatment at a stage when brain tissue might still be salvageable, thus avoiding terrible handicaps. On the other hand, it was found that water diffusion is anisotropic in white matter, because axon membranes limit molecular movement perpendicularly to the nerve fibers. This feature can be exploited to produce stunning maps of the orientation in space of the white matter tracts and brain connections in just a few minutes. Diffusion MR imaging is now also rapidly expanding in oncology, for the detection of malignant lesions and metastases, as well as monitoring. Water diffusion is usually largely decreased in malignant tissues, and body diffusion MR imaging, which does not require any tracer injection, is rapidly becoming a modality of choice to detect, characterize, or even stage malignant lesions, especially for breast or prostate cancer. After a brief summary of the key methodological concepts beyond diffusion MR imaging, this article will give a review of the clinical literature, mainly focusing on current outstanding issues, followed by some innovative proposals for future improvements.
Collapse
Affiliation(s)
- Mami Iima
- From the Department of Diagnostic Imaging and Nuclear Medicine (M.I.) and the Human Brain Research Center (D.L.B.), Kyoto University Graduate School of Medicine, and the Hakubi Center for Advanced Research (M.I.), Kyoto University, Kyoto, Japan; and NeuroSpin, CEA/DSV/I2BM, Bât 145, Point Courrier 156, CEA-Saclay Center, F-91191 Gif-sur-Yvette, France (D.L.B.)
| | - Denis Le Bihan
- From the Department of Diagnostic Imaging and Nuclear Medicine (M.I.) and the Human Brain Research Center (D.L.B.), Kyoto University Graduate School of Medicine, and the Hakubi Center for Advanced Research (M.I.), Kyoto University, Kyoto, Japan; and NeuroSpin, CEA/DSV/I2BM, Bât 145, Point Courrier 156, CEA-Saclay Center, F-91191 Gif-sur-Yvette, France (D.L.B.)
| |
Collapse
|
43
|
Cui L, Yin JB, Hu CH, Gong SC, Xu JF, Yang JS. Inter- and intraobserver agreement of ADC measurements of lung cancer in free breathing, breath-hold and respiratory triggered diffusion-weighted MRI. Clin Imaging 2016; 40:892-6. [PMID: 27183136 DOI: 10.1016/j.clinimag.2016.04.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Revised: 03/28/2016] [Accepted: 04/08/2016] [Indexed: 12/24/2022]
Abstract
OBJECTIVE To prospectively evaluate the inter- and intraobserver agreement of apparent diffusion coefficient (ADC) measurements in free breathing, breath-hold, and respiratory triggered diffusion-weighted imaging (DWI) of lung cancer. METHODS Twenty-two patients with lung cancer (tumor size >2cm) underwent DWIs (3.0T) in three imaging methods. Lesion ADCs were measured twice by both of the two independent observers and compared. RESULTS No statistical significance was found among methods, though respiratory-triggered DWI tended to have higher ADCs than breath-hold DWI. Great inter- and intraobserver agreement was shown. CONCLUSION ADCs had good inter- and intraobserver agreement in all three DWI methods.
Collapse
Affiliation(s)
- Lei Cui
- Department of Radiology, First Affiliated Hospital of Soochow University, 188 Shixi Street, Suzhou, Jiangsu, PR China, 215006; Department of Radiology, Second Affiliated Hospital of Nantong University, 6 Hai'er Road, Chongchuan District, Nantong, Jiangsu, PR China, 226001
| | - Jian-Bing Yin
- Department of Radiology, Second Affiliated Hospital of Nantong University, 6 Hai'er Road, Chongchuan District, Nantong, Jiangsu, PR China, 226001
| | - Chun-Hong Hu
- Department of Radiology, First Affiliated Hospital of Soochow University, 188 Shixi Street, Suzhou, Jiangsu, PR China, 215006.
| | - Shen-Chu Gong
- Department of Radiology, Second Affiliated Hospital of Nantong University, 6 Hai'er Road, Chongchuan District, Nantong, Jiangsu, PR China, 226001.
| | - Jun-Feng Xu
- Department of Radiology, Second Affiliated Hospital of Nantong University, 6 Hai'er Road, Chongchuan District, Nantong, Jiangsu, PR China, 226001
| | - Ju-Shun Yang
- Department of Radiology, Second Affiliated Hospital of Nantong University, 6 Hai'er Road, Chongchuan District, Nantong, Jiangsu, PR China, 226001
| |
Collapse
|
44
|
Jha AK, Rodríguez JJ, Stopeck AT. A maximum-likelihood method to estimate a single ADC value of lesions using diffusion MRI. Magn Reson Med 2016; 76:1919-1931. [PMID: 26743234 DOI: 10.1002/mrm.26072] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2015] [Revised: 10/27/2015] [Accepted: 11/09/2015] [Indexed: 11/09/2022]
Abstract
PURPOSE Design a statistically rigorous procedure to estimate a single apparent diffusion coefficient (ADC) of lesion from the mean lesion signal intensity in diffusion MRI. THEORY AND METHODS A rigorous maximum-likelihood technique that incorporated the statistics of the mean lesion intensity and accounted for lesion heterogeneity was derived to estimate the ADC value. Performance evaluation included comparison with the conventionally used linear-regression and a statistically rigorous state-of-the-art ADC-map technique using realistic and clinically relevant simulation studies conducted with assistance of patient data for homogeneous and heterogeneous lesion models. RESULTS The proposed technique outperformed the linear-regression and ADC-map approaches over a large spectrum of signal-to-noise ratio, ADC, lesion size, image-misalignment parameters, including at no image misalignment, and different amounts of lesion heterogeneity. The method was also superior at different sets of b values and in studies from specific patient-image-derived data. The technique took less than a second to execute. CONCLUSIONS A rigorous, computationally fast, easy-to-implement, and convenient-to-use maximum-likelihood technique was proposed to estimate a single ADC value of the lesion. Results provide strong evidence in support of the method. Magn Reson Med 76:1919-1931, 2016. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Abhinav K Jha
- Division of Medical Imaging Physics, Department of Radiology and Radiological Sciences, Johns Hopkins Medical Institutions, Baltimore, Maryland, USA
| | - Jeffrey J Rodríguez
- Department of Electrical and Computer Engineering, University of Arizona, Tucson, Arizona, USA
| | - Alison T Stopeck
- Department of Medicine, Stony Brook Cancer Center, SUNY Stony Brook, Stony Brook, New York, USA
| |
Collapse
|
45
|
Ni P, Lin Y, Zhong Q, Chen Z, Sandrasegaran K, Lin C. Technical advancements and protocol optimization of diffusion-weighted imaging (DWI) in liver. Abdom Radiol (NY) 2016; 41:189-202. [PMID: 26830624 DOI: 10.1007/s00261-015-0602-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
An area of rapid advancement in abdominal MRI is diffusion-weighted imaging (DWI). By measuring diffusion properties of water molecules, DWI is capable of non-invasively probing tissue properties and physiology at cellular and macromolecular level. The integration of DWI as part of abdominal MRI exam allows better lesion characterization and therefore more accurate initial diagnosis and treatment monitoring. One of the most technical challenging, but also most useful abdominal DWI applications is in liver and therefore requires special attention and careful optimization. In this article, the latest technical developments of DWI and its liver applications are reviewed with the explanations of the technical principles, recommendations of the imaging parameters, and examples of clinical applications. More advanced DWI techniques, including Intra-Voxel Incoherent Motion (IVIM) diffusion imaging, anomalous diffusion imaging, and Diffusion Kurtosis Imaging (DKI) are discussed.
Collapse
Affiliation(s)
- Ping Ni
- Department of Medical Imaging, Fuzhou General Hospital, Fuzhou, Fujian, China
| | - Yuning Lin
- Department of Medical Imaging, Fuzhou General Hospital, Fuzhou, Fujian, China
| | - Qun Zhong
- Department of Medical Imaging, Fuzhou General Hospital, Fuzhou, Fujian, China
| | - Ziqian Chen
- Department of Medical Imaging, Fuzhou General Hospital, Fuzhou, Fujian, China
| | - Kumar Sandrasegaran
- Department of Radiology and Imaging Science, Indiana University School of Medicine, 950 West Walnut St. R2 E124, Indianapolis, IN, 46202, USA
| | - Chen Lin
- Department of Radiology and Imaging Science, Indiana University School of Medicine, 950 West Walnut St. R2 E124, Indianapolis, IN, 46202, USA.
| |
Collapse
|
46
|
Jahic E, Sofic A, Selimovic AH. DWI/ADC in Differentiation of Benign from Malignant Focal Liver Lesion. Acta Inform Med 2016; 24:244-247. [PMID: 27708485 PMCID: PMC5037977 DOI: 10.5455/aim.2016.24.244-247] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Accepted: 06/24/2016] [Indexed: 12/11/2022] Open
Abstract
Material and methods: The study was of prospective-retrospective character. It was carried out at the AKH in Vienna (Austria), where 100 patients with focal liver lesions were included in the study. All patients underwent the routine MR sequences on appliances 1,5 and 3T (Siemens, Germany): T1, T2, HASTE, VIBE, and a DWI with three b values (b 50, b 300 b 600 s / mm2) and ADC map with ROI (regions of interest). The numerical value of ADC map was calculated, where n = 100 liver lesions, by two independent radiologists. Results: On the basis of matching the PH finding statistically we get DWI accuracy of 96.8% for the assessment of liver lesions. The average numerical value of ADC in benign hepatic lesions (FNH, Hemangiomas) in our study amounted to 1.88 (1.326 to 2.48) x103 mm2 /s, while the value of malignant liver lesions (HCC, CCC, CRCLM) were significantly lower and amounted to 1.15 (1.024 to 1.343) x10-3 mm2 /s (Figure 2). Differences between the mean ADC of benign and malignant lesions showed a statistically significant difference with p <0.0005. In our research, we get cut-off for the ADC value of 1,341x10-3 mm2 /s, which proved to be the optimal parameter for differentiation between benign and malignant lesions. Conclusion: Measuring ADC values with DWI as an additional MRI tool can help in oncological practice by distinguishing normal liver parenchyma from focal lesions, and in differentiating benign from malignant liver lesions, particularly in cases where administration of contrast is not possible.
Collapse
Affiliation(s)
- Elma Jahic
- Clinic of Radiology, Clinical Center of Sarajevo University, Sarajevo, Bosnia and Herzegovina
| | - Amela Sofic
- Clinic of Radiology, Clinical Center of Sarajevo University, Sarajevo, Bosnia and Herzegovina
| | - Azra Husic Selimovic
- Institute of Gastroenterology, Clinical Center of Sarajevo University, Sarajevo, Bosnia and Herzegovina
| |
Collapse
|
47
|
Comparison of Free-Breathing With Navigator-Triggered Technique in Diffusion Weighted Imaging for Evaluation of Small Hepatocellular Carcinoma: Effect on Image Quality and Intravoxel Incoherent Motion Parameters. J Comput Assist Tomogr 2015. [PMID: 26196345 DOI: 10.1097/rct.0000000000000278] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
OBJECTIVE To evaluate the effect on image quality and intravoxel incoherent motion (IVIM) parameters of small hepatocellular carcinoma (HCC) from choice of either free-breathing (FB) or navigator-triggered (NT) diffusion-weighted (DW) imaging. METHODS Thirty patients with 37 small HCCs underwent IVIM DW imaging using 12 b values (0-800 s/mm) with 2 sequences: NT, FB. A biexponential analysis with the Bayesian method yielded true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) in small HCCs and liver parenchyma. Apparent diffusion coefficient (ADC) was also calculated. The acquisition time and image quality scores were assessed for 2 sequences. Independent sample t test was used to compare image quality, signal intensity ratio, IVIM parameters, and ADC values between the 2 sequences; reproducibility of IVIM parameters, and ADC values between 2 sequences was assessed with the Bland-Altman method (BA-LA). RESULTS Image quality with NT sequence was superior to that with FB acquisition (P = 0.02). The mean acquisition time for FB scheme was shorter than that of NT sequence (6 minutes 14 seconds vs 10 minutes 21 seconds ± 10 seconds P < 0.01). The signal intensity ratio of small HCCs did not vary significantly between the 2 sequences. The ADC and IVIM parameters from the 2 sequences show no significant difference. Reproducibility of D*and f parameters in small HCC was poor (BA-LA: 95% confidence interval, -180.8% to 189.2% for D* and -133.8% to 174.9% for f). A moderate reproducibility of D and ADC parameters was observed (BA-LA: 95% confidence interval, -83.5% to 76.8% for D and -74.4% to 88.2% for ADC) between the 2 sequences. CONCLUSIONS The NT DW imaging technique offers no advantage in IVIM parameters measurements of small HCC except better image quality, whereas FB technique offers greater confidence in fitted diffusion parameters for matched acquisition periods.
Collapse
|
48
|
Ludwig JM, Camacho JC, Kokabi N, Xing M, Kim HS. The Role of Diffusion-Weighted Imaging (DWI) in Locoregional Therapy Outcome Prediction and Response Assessment for Hepatocellular Carcinoma (HCC): The New Era of Functional Imaging Biomarkers. Diagnostics (Basel) 2015; 5:546-63. [PMID: 26854170 PMCID: PMC4728474 DOI: 10.3390/diagnostics5040546] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2015] [Revised: 11/12/2015] [Accepted: 11/19/2015] [Indexed: 12/12/2022] Open
Abstract
Reliable response criteria are critical for the evaluation of therapeutic response in hepatocellular carcinoma (HCC). Current response assessment is mainly based on: (1) changes in size, which is at times unreliable and lag behind the result of therapy; and (2) contrast enhancement, which can be difficult to quantify in the presence of benign post-procedural changes and in tumors presenting with a heterogeneous pattern of enhancement. Given these challenges, functional magnetic resonance imaging (MRI) techniques, such as diffusion-weighted imaging (DWI) have been recently investigated, aiding specificity to locoregional therapy response assessment and outcome prediction. Briefly, DWI quantifies diffusion of water occurring naturally at a cellular level (Brownian movement), which is restricted in multiple neoplasms because of high cellularity. Disruption of cellular integrity secondary to therapy results in increased water diffusion across the injured membranes. This review will provide an overview of the current literature on DWI therapy response assessment and outcome prediction in HCC following treatment with locoregional therapies.
Collapse
Affiliation(s)
- Johannes M Ludwig
- Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT 06510, USA.
| | - Juan C Camacho
- Division of Interventional Radiology and Image-guided Medicine, Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA 30322, USA.
| | - Nima Kokabi
- Division of Interventional Radiology and Image-guided Medicine, Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA 30322, USA.
| | - Minzhi Xing
- Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT 06510, USA.
| | - Hyun S Kim
- Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT 06510, USA.
- Yale Cancer Center, Yale School of Medicine, New Haven, CT 06519, USA.
| |
Collapse
|
49
|
Yuan Z, Zhang J, Yang H, Ye XD, Xu LC, Li WT. Diffusion-Weighted MR Imaging of Hepatocellular Carcinoma: Current Value in Clinical Evaluation of Tumor Response to Locoregional Treatment. J Vasc Interv Radiol 2015; 27:20-30; quiz 31. [PMID: 26621785 DOI: 10.1016/j.jvir.2015.10.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Revised: 10/01/2015] [Accepted: 10/02/2015] [Indexed: 02/07/2023] Open
Abstract
The established size-based image biomarkers for tumor burden measurement continue to be applied to solid tumors, as size measurement can easily be used in clinical practice. However, in the setting of novel targeted therapies and liver-directed locoregional treatments for hepatocellular carcinoma (HCC), simple tumor anatomic changes can be less informative and usually appear later than biologic changes. Functional magnetic resonance (MR) imaging has the potential to be a promising technique for assessment of HCC response to therapy. Diffusion-weighted MR imaging is now widely used as a standard imaging modality to evaluate the liver. This review discusses the current clinical value of diffusion-weighted MR imaging in the evaluation of tumor response after nonsurgical locoregional treatment of HCC.
Collapse
Affiliation(s)
- Zheng Yuan
- Department of Radiology, Shanghai 85 Hospital; Department of Interventional Radiology, Shanghai Cancer Hospital, Fudan University.
| | - Jian Zhang
- Department of Nuclear Medicine, Xinhua Hospital affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China
| | - Huan Yang
- Department of Interventional Radiology, Shanghai Cancer Hospital, Fudan University
| | - Xiao-Dan Ye
- Department of Radiology, Xinhua Hospital affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China
| | - Li-Chao Xu
- Department of Interventional Radiology, Shanghai Cancer Hospital, Fudan University
| | - Wen-Tao Li
- Department of Interventional Radiology, Shanghai Cancer Hospital, Fudan University
| |
Collapse
|
50
|
Metens T, Absil J, Denolin V, Bali MA, Matos C. Liver apparent diffusion coefficient repeatability with individually predetermined optimal cardiac timing and artifact elimination by signal filtering. J Magn Reson Imaging 2015; 43:1100-10. [DOI: 10.1002/jmri.25089] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Accepted: 10/26/2015] [Indexed: 12/11/2022] Open
Affiliation(s)
- Thierry Metens
- MRI Clinics; Department of Radiology; Hopital Erasme; Universite Libre de Bruxelles; Bruxelles Belgium
| | - Julie Absil
- MRI Clinics; Department of Radiology; Hopital Erasme; Universite Libre de Bruxelles; Bruxelles Belgium
| | | | - Maria Antonietta Bali
- MRI Clinics; Department of Radiology; Hopital Erasme; Universite Libre de Bruxelles; Bruxelles Belgium
| | - Celso Matos
- MRI Clinics; Department of Radiology; Hopital Erasme; Universite Libre de Bruxelles; Bruxelles Belgium
| |
Collapse
|