1
|
Xiang J, Lamy J, Qiu M, Galiana G, Peters DC. K-t PCA accelerated in-plane balanced steady-state free precession phase-contrast (PC-SSFP) for all-in-one diastolic function evaluation. Magn Reson Med 2024; 91:911-925. [PMID: 37927206 PMCID: PMC10803002 DOI: 10.1002/mrm.29897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 10/04/2023] [Accepted: 10/05/2023] [Indexed: 11/07/2023]
Abstract
PURPOSE Diastolic function evaluation requires estimates of early and late diastolic mitral filling velocities (E and A) and of mitral annulus tissue velocity (e'). We aimed to develop an MRI method for simultaneous all-in-one diastolic function evaluation in a single scan by generating a 2D phase-contrast (PC) sequence with balanced steady-state free precession (bSSFP) contrast (PC-SSFP). E and A could then be measured with PC, and e' estimated by valve tracking on the magnitude images, using an established deep learning framework. METHODS Our PC-SSFP used in-plane flow-encoding, with zeroth and first moment nulling over each TR. For further acceleration, different k-t principal component analysis (PCA) methods were investigated with both retrospective and prospective undersampling. PC-SSFP was compared to separate balanced SSFP cine and PC-gradient echo acquisitions in phantoms and in 10 healthy subjects. RESULTS Phantom experiments showed that PC-SSFP measured accurate velocities compared to PC-gradient echo (r = 0.98 for a range of pixel-wise velocities -80 cm/s to 80 cm/s). In subjects, PC-SSFP generated high SNR and myocardium-blood contrast, and excellent agreement for E (limits of agreement [LOA] 0.8 ± 2.4 cm/s, r = 0.98), A (LOA 2.5 ± 4.1 cm/s, r = 0.97), and e' (LOA 0.3 ± 2.6 cm/s, r = 1.00), versus the standard methods. The best k-t PCA approach processed the complex difference data and substituted in raw k-space data. With prospective k-t PCA acceleration, higher frame rates were achieved (50 vs. 25 frames per second without k-t PCA), yielding a 13% higher e'. CONCLUSION The proposed PC-SSFP method achieved all-in-one diastolic function evaluation.
Collapse
Affiliation(s)
- Jie Xiang
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
| | - Jerome Lamy
- Université de Paris, Cardiovascular Research Center, INSERM, 75015 Paris, France
| | - Maolin Qiu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States
| | - Gigi Galiana
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States
| | - Dana C. Peters
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States
| |
Collapse
|
2
|
Dyverfeldt P, Bissell M, Barker AJ, Bolger AF, Carlhäll CJ, Ebbers T, Francios CJ, Frydrychowicz A, Geiger J, Giese D, Hope MD, Kilner PJ, Kozerke S, Myerson S, Neubauer S, Wieben O, Markl M. 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson 2015; 17:72. [PMID: 26257141 PMCID: PMC4530492 DOI: 10.1186/s12968-015-0174-5] [Citation(s) in RCA: 563] [Impact Index Per Article: 62.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Accepted: 07/17/2015] [Indexed: 02/07/2023] Open
Abstract
Pulsatile blood flow through the cavities of the heart and great vessels is time-varying and multidirectional. Access to all regions, phases and directions of cardiovascular flows has formerly been limited. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has enabled more comprehensive access to such flows, with typical spatial resolution of 1.5×1.5×1.5 - 3×3×3 mm(3), typical temporal resolution of 30-40 ms, and acquisition times in the order of 5 to 25 min. This consensus paper is the work of physicists, physicians and biomedical engineers, active in the development and implementation of 4D Flow CMR, who have repeatedly met to share experience and ideas. The paper aims to assist understanding of acquisition and analysis methods, and their potential clinical applications with a focus on the heart and greater vessels. We describe that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy. We also specify research and development goals that have yet to be satisfactorily achieved. Derived flow parameters, generally needing further development or validation for clinical use, include measurements of wall shear stress, pressure difference, turbulent kinetic energy, and intracardiac flow components. The dependence of measurement accuracy on acquisition parameters is considered, as are the uses of different visualization strategies for appropriate representation of time-varying multidirectional flow fields. Finally, we offer suggestions for more consistent, user-friendly implementation of 4D Flow CMR acquisition and data handling with a view to multicenter studies and more widespread adoption of the approach in routine clinical investigations.
Collapse
Affiliation(s)
- Petter Dyverfeldt
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
| | - Malenka Bissell
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK.
| | - Alex J Barker
- Department of Radiology, Northwestern University, Chicago, USA.
| | - Ann F Bolger
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
- Department of Medicine, University of California San Francisco, San Francisco, CA, United States.
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
- Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
| | | | - Alex Frydrychowicz
- Klinik für Radiologie und Nuklearmedizin, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
| | - Julia Geiger
- Department of Radiology, University Children's Hospital Zurich, Zurich, Switzerland.
| | - Daniel Giese
- Department of Radiology, University Hospital of Cologne, Cologne, Germany.
| | - Michael D Hope
- Department of Radiology, University of California San Francisco, San Francisco, CA, United States.
| | - Philip J Kilner
- NIHR Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, National Heart and Lung Institute, Imperial College, London, UK.
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.
| | - Saul Myerson
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK.
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK.
| | - Oliver Wieben
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.
| | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, USA.
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, USA.
| |
Collapse
|