1
|
Waddington DEJ, Sarracanie M, Salameh N, Herisson F, Ayata C, Rosen MS. An Overhauser-enhanced-MRI platform for dynamic free radical imaging in vivo. NMR IN BIOMEDICINE 2018; 31:e3896. [PMID: 29493032 DOI: 10.1002/nbm.3896] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2017] [Revised: 12/20/2017] [Accepted: 12/21/2017] [Indexed: 06/08/2023]
Abstract
Overhauser-enhanced MRI (OMRI) is an electron-proton double-resonance imaging technique of interest for its ability to non-invasively measure the concentration and distribution of free radicals. In vivo OMRI experiments are typically undertaken at ultra-low magnetic field (ULF), as both RF power absorption and penetration issues-a consequence of the high resonance frequencies of electron spins-are mitigated. However, working at ULF causes a drastic reduction in MRI sensitivity. Here, we report on the design, construction and performance of an OMRI platform optimized for high NMR sensitivity and low RF power absorbance, exploring challenges unique to probe design in the ULF regime. We use this platform to demonstrate dynamic imaging of TEMPOL in a rat model. The work presented here demonstrates improved speed and sensitivity of in vivo OMRI, extending the scope of OMRI to the study of dynamic processes such as metabolism.
Collapse
Affiliation(s)
- David E J Waddington
- A. A. Martinos Center for Biomedical Imaging, 149 Thirteenth St., Charlestown, MA 02129, USA
- Department of Physics, Harvard University, 17 Oxford St, Cambridge, MA 02138, USA
- ARC Centre of Excellence for Engineered Quantum Systems, School of Physics, The University of Sydney, Sydney, NSW 2006, Australia
| | - Mathieu Sarracanie
- A. A. Martinos Center for Biomedical Imaging, 149 Thirteenth St., Charlestown, MA 02129, USA
- Department of Physics, Harvard University, 17 Oxford St, Cambridge, MA 02138, USA
- Harvard Medical School, 25 Shattuck St., Boston, MA 02115, USA
| | - Najat Salameh
- A. A. Martinos Center for Biomedical Imaging, 149 Thirteenth St., Charlestown, MA 02129, USA
- Department of Physics, Harvard University, 17 Oxford St, Cambridge, MA 02138, USA
- Harvard Medical School, 25 Shattuck St., Boston, MA 02115, USA
| | - Fanny Herisson
- Stroke and Neurovascular Regulation Laboratory, Departments of Radiology and Neurology, Massachusetts General Hospital/Harvard Medical School, Charlestown, MA 02129, USA
| | - Cenk Ayata
- Harvard Medical School, 25 Shattuck St., Boston, MA 02115, USA
- Stroke and Neurovascular Regulation Laboratory, Departments of Radiology and Neurology, Massachusetts General Hospital/Harvard Medical School, Charlestown, MA 02129, USA
| | - Matthew S Rosen
- A. A. Martinos Center for Biomedical Imaging, 149 Thirteenth St., Charlestown, MA 02129, USA
- Department of Physics, Harvard University, 17 Oxford St, Cambridge, MA 02138, USA
- Harvard Medical School, 25 Shattuck St., Boston, MA 02115, USA
| |
Collapse
|
2
|
Griendling KK, Touyz RM, Zweier JL, Dikalov S, Chilian W, Chen YR, Harrison DG, Bhatnagar A. Measurement of Reactive Oxygen Species, Reactive Nitrogen Species, and Redox-Dependent Signaling in the Cardiovascular System: A Scientific Statement From the American Heart Association. Circ Res 2016; 119:e39-75. [PMID: 27418630 DOI: 10.1161/res.0000000000000110] [Citation(s) in RCA: 264] [Impact Index Per Article: 33.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Reactive oxygen species and reactive nitrogen species are biological molecules that play important roles in cardiovascular physiology and contribute to disease initiation, progression, and severity. Because of their ephemeral nature and rapid reactivity, these species are difficult to measure directly with high accuracy and precision. In this statement, we review current methods for measuring these species and the secondary products they generate and suggest approaches for measuring redox status, oxidative stress, and the production of individual reactive oxygen and nitrogen species. We discuss the strengths and limitations of different methods and the relative specificity and suitability of these methods for measuring the concentrations of reactive oxygen and reactive nitrogen species in cells, tissues, and biological fluids. We provide specific guidelines, through expert opinion, for choosing reliable and reproducible assays for different experimental and clinical situations. These guidelines are intended to help investigators and clinical researchers avoid experimental error and ensure high-quality measurements of these important biological species.
Collapse
|
3
|
Samouilov A, Efimova OV, Bobko AA, Sun Z, Petryakov S, Eubank TD, Trofimov DG, Kirilyuk IA, Grigor'ev IA, Takahashi W, Zweier JL, Khramtsov VV. In vivo proton-electron double-resonance imaging of extracellular tumor pH using an advanced nitroxide probe. Anal Chem 2014; 86:1045-52. [PMID: 24372284 DOI: 10.1021/ac402230h] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A variable radio frequency proton-electron double-resonance imaging (VRF PEDRI) approach for pH mapping of aqueous samples has been recently developed (Efimova et al. J. Magn. Reson. 2011, 209, 227-232). A pH map is extracted from two PEDRI acquisitions performed at electron paramagnetic resonance (EPR) frequencies of protonated and unprotonated forms of a pH-sensitive probe. To translate VRF PEDRI to an in vivo setting, an advanced pH probe was synthesized. Probe deuteration resulted in a narrow spectral line of 1.2 G compared to a nondeuterated analogue line width of 2.1 G allowing for an increase of Overhauser enhancements and reduction in rf power deposition. Binding of the probe to the cell-impermeable tripeptide, glutathione (GSH), allows for targeting to extracellular tissue space for monitoring extracellular tumor acidosis, a prognostic factor in tumor pathophysiology. The probe demonstrated pH sensitivity in the 5.8-7.8 range, optimum for measurement of acidic extracellular tumor pH (pH(e)). In vivo VRF PEDRI was performed on Met-1 tumor-bearing mice. Compared to normal mammary glands with a neutral mean pH(e) (7.1 ± 0.1), we observed broader pH distribution with acidic mean pH(e) (6.8 ± 0.1) in tumor tissue. In summary, VRF PEDRI in combination with a newly developed pH probe provides an analytical approach for spatially resolved noninvasive pHe monitoring, in vivo.
Collapse
Affiliation(s)
- Alexandre Samouilov
- The Dorothy M. Davis Heart and Lung Research Institute: ‡Division of Pulmonary, Allergy, Critical Care, and Sleep Medicine, and §Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University , Columbus, Ohio 43210, United States
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Sarracanie M, Armstrong BD, Stockmann J, Rosen MS. High speed 3D overhauser-enhanced MRI using combined b-SSFP and compressed sensing. Magn Reson Med 2013; 71:735-45. [DOI: 10.1002/mrm.24705] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Mathieu Sarracanie
- Department of Physics; Harvard University; Cambridge Massachusetts USA
- Department of Radiology, A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital; Boston Massachusetts USA
| | - Brandon D. Armstrong
- Department of Physics; Harvard University; Cambridge Massachusetts USA
- Department of Radiology, A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital; Boston Massachusetts USA
| | - Jason Stockmann
- Department of Physics; Harvard University; Cambridge Massachusetts USA
- Department of Radiology, A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital; Boston Massachusetts USA
| | - Matthew S. Rosen
- Department of Physics; Harvard University; Cambridge Massachusetts USA
- Department of Radiology, A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital; Boston Massachusetts USA
- Department of Radiology, Harvard Medical School; Boston Massachusetts USA
| |
Collapse
|