1
|
Qian Z, Liu R, Wu Z, Hsu YC, Fu C, Sun Y, Wu D, Zhang Y. Saturation-prolongated and inhomogeneity-mitigated chemical exchange saturation transfer imaging with parallel transmission. NMR IN BIOMEDICINE 2023; 36:e4689. [PMID: 34994025 DOI: 10.1002/nbm.4689] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 12/20/2021] [Accepted: 01/04/2022] [Indexed: 05/23/2023]
Abstract
Chemical exchange saturation transfer (CEST) imaging benefits from a longer saturation duration and a higher saturation duty cycle. Dielectric shading effects occur when the radiofrequency (RF) wavelength approaches the object size. Here, we proposed a simultaneous parallel transmission-based CEST (pTx-CEST) sequence to prolongate the saturation duration at a 100% duty cycle and improve the RF saturation homogeneity in CEST imaging. The simultaneous pTx-CEST sequence was implemented by switching the CEST saturation module from the non-pTx to pTx mode, using the pTx functionality with both transmit channels being driven simultaneously (instead of time-interleaved). The optimization of amplitude ratio and phase difference settings between RF channels for best B1 homogeneity was performed in phantoms of two different sizes mimicking the human brain and abdomen. The optimal amplitude and phase settings generating the best B1 homogeneity in the phantoms were used in pTx-CEST scans of the human study. The comparison of the maximum achievable saturation duration between the non-pTx-CEST and pTx-CEST sequences was performed in a protein phantom, healthy volunteers, and a metastatic brain tumor patient. The optimal amplitude ratio and phase difference setting between transmit channels manifested circular and elliptical polarization in the head-sized and abdomen-sized phantoms. In the brain, the maximum saturation durations achieved at a 100% duty cycle using the simultaneous pTx-CEST sequence were prolonged to 2240, 3220, and 4200 ms compared with 980 ms using the non-pTx-CEST sequence at repetition times of 3, 4, and 5 s, respectively. The longer saturation duration helped improve the image contrast between the tumor and the normal tissue in the patient. The optimized elliptical polarization mode saturation pulses yielded improved uniformity of CEST signals acquired from the human abdomen. The proposed simultaneous pTx-CEST sequence enabled essentially arbitrarily long saturation duration at a 100% duty cycle and helped reduce the dielectric shading effects with the optimized RF setting.
Collapse
Affiliation(s)
- Zihua Qian
- Department of Radiology, The Children's Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Ruibin Liu
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Zhe Wu
- Techna Institute, University Health Network, Toronto, Ontario, Canada
| | - Yi-Cheng Hsu
- MR Collaboration, Siemens Healthcare Ltd., Shanghai, China
| | - Caixia Fu
- MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Yi Sun
- MR Collaboration, Siemens Healthcare Ltd., Shanghai, China
| | - Dan Wu
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
- Cancer Center, Zhejiang University, Hangzhou, Zhejiang, China
| | - Yi Zhang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
- Cancer Center, Zhejiang University, Hangzhou, Zhejiang, China
| |
Collapse
|
2
|
Yao FF, Zhang Y. A review of quantitative diffusion-weighted MR imaging for breast cancer: Towards noninvasive biomarker. Clin Imaging 2023; 98:36-58. [PMID: 36996598 DOI: 10.1016/j.clinimag.2023.03.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 03/03/2023] [Accepted: 03/21/2023] [Indexed: 04/01/2023]
Abstract
Quantitative diffusion-weighted imaging (DWI) is an important adjunct to conventional breast MRI and shows promise as a noninvasive biomarker of breast cancer in multiple clinical scenarios, from the discrimination of benign and malignant lesions, prediction, and evaluation of treatment response to a prognostic assessment of breast cancer. Various quantitative parameters are derived from different DWI models based on special prior knowledge and assumptions, have different meanings, and are easy to confuse. In this review, we describe the quantitative parameters derived from conventional and advanced DWI models commonly used in breast cancer and summarize the promising clinical applications of these quantitative parameters. Although promising, it is still challenging for these quantitative parameters to become clinically useful noninvasive biomarkers in breast cancer, as multiple factors may result in variations in quantitative parameter measurements. Finally, we briefly describe some considerations regarding the factors that cause variations.
Collapse
Affiliation(s)
- Fei-Fei Yao
- Department of MRI in the First Affiliated Hospital, Zhengzhou University, Zhengzhou, China.
| | - Yan Zhang
- Department of MRI in the First Affiliated Hospital, Zhengzhou University, Zhengzhou, China
| |
Collapse
|
3
|
Zhu D, Schär M, Qin Q. Ultrafast B1 mapping with RF-prepared 3D FLASH acquisition: Correcting the bias due to T 1 -induced k-space filtering effect. Magn Reson Med 2022; 88:757-769. [PMID: 35381114 PMCID: PMC9232926 DOI: 10.1002/mrm.29247] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 03/06/2022] [Accepted: 03/07/2022] [Indexed: 01/25/2023]
Abstract
Purpose The traditional radiofrequency (RF)‐prepared B1 mapping technique consists of one scan with an RF preparation module for flip angle‐encoding and a second scan without this module for normalizing. To reduce the T1‐induced k‐space filtering effect, this method is limited to 2D FLASH acquisition with a two‐parameter method. A novel 3D RF‐prepared three‐parameter method for ultrafast B1‐mapping is proposed to correct the T1‐induced quantification bias. Theory The point spread function analysis of FLASH shows that the prepared longitudinal magnetization before the FLASH acquisition and the image signal obeys a linear (not proportional) relationship. The intercept of the linear function causes the quantification bias and can be captured by a third saturated scan. Methods Using the 2D double‐angle method (DAM) as the reference, a 3D RF‐prepared three‐parameter protocol with 9 s duration was compared with the two‐parameter method, as well as the saturated DAM (SDAM) method, the dual refocusing echo acquisition mode (DREAM) method, and the actual flip‐angle imaging (AFI) method, for B1 mapping of brain, breast, and abdomen with different orientations and shim settings at 3T. Results The 3D RF‐prepared three‐parameter method with complex‐subtraction delivered consistently lower RMS error, error mean, error standard deviation, and higher concordance correlation coefficients values than the two‐parameter method, the three‐parameter method with magnitude‐subtraction, the multi‐slice DREAM and the 3D AFI, and were close to the results of 2D or multi‐slice SDAM. Conclusion The proposed ultrafast 3D RF‐prepared three‐parameter method with complex‐subtraction was demonstrated with high accuracy for B1 mapping of brain, breast, and abdomen.
Collapse
Affiliation(s)
- Dan Zhu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA.,The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Michael Schär
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Qin Qin
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA.,The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
4
|
He M, Xu J, Sun Z, Wang X, Wang J, Feng F, Xue H, Jin Z. Prospective Comparison of Reduced Field-of-View (rFOV) and Full FOV (fFOV) Diffusion-Weighted Imaging (DWI) in the Assessment of Insulinoma: Image Quality and Lesion Detection. Acad Radiol 2020; 27:1572-1579. [PMID: 31954606 DOI: 10.1016/j.acra.2019.11.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Revised: 11/27/2019] [Accepted: 11/27/2019] [Indexed: 02/07/2023]
Abstract
RATIONALE AND OBJECTIVES To prospectively compare the image quality (IQ) and lesion detection performance of reduced field-of-view (rFOV) and full FOV (fFOV) diffusion-weighted imaging (DWI) sequences in detecting insulinomas. MATERIALS AND METHODS From October 2017 to September 2018, 67 patients with suspected insulinomas were prospectively enrolled and underwent imaging with both types of DWI sequences. The slice thickness (4 mm) and slice gaps (1 mm) were the same for the two DWI sequences, and the TR/TE was 2235/56 ms for the rFOV sequence and 1892/63 ms for the fFOV sequence. Three radiologists independently assessed the imaging quality (IQ) subjectively with a 5-point scale and objectively with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. The IQ scores, CNR, SNR, lesion detection rates, and ADC values were compared. Receiver operating characteristic curves were generated, and the area under the curve (AUC) was used to compare the diagnostic performance. RESULTS Fifty patients were tumor positive, with 65 tumors (size: 1.31 ± 0.77 cm, range: 0.6-5.8 cm). The IQ score, SNR, and CNR were significantly higher for rFOV DWI than for fFOV DWI (IQ: 3.64 ± 0.487 vs 3.310 ± 0.577, SNR: 22.520 ± 8.690 vs 10.284 ± 3.321, CNR: 3.454 ± 2.642 vs 1.327 ± 2.801, and all p < 0.05). For lesions less than 1.5 cm (n = 55), the lesion detection rates of the rFOV were statistically improved compared to those of the fFOV (90.7% vs. 75.9%, p = 0.039). The sensitivity of lesion detection was significantly improved with the rFOV-DWI sequences compared to that with the fFOV-DWI sequences (0.924 vs. 0.773, p = 0.013). The ADC values of the two DWI sequences were consistent for insulinomas and normal parenchyma. CONCLUSION Considering the improvements in overall IQ and lesion detection and the consistency of ADC measurements, we suggest that rFOV DWI is a reliable auxiliary alternative to fFOV DWI for clinical practice in the detection of pancreatic insulinomas.
Collapse
Affiliation(s)
- Ming He
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan No.1. Dongcheng District, Beijing, China
| | - Jin Xu
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan No.1. Dongcheng District, Beijing, China
| | - Zhaoyong Sun
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan No.1. Dongcheng District, Beijing, China
| | | | | | - Feng Feng
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan No.1. Dongcheng District, Beijing, China
| | - Huadan Xue
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan No.1. Dongcheng District, Beijing, China.
| | - Zhengyu Jin
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan No.1. Dongcheng District, Beijing, China
| |
Collapse
|
5
|
Xu F, Li W, Liu D, Zhu D, Schär M, Myers K, Qin Q. A novel spectrally selective fat saturation pulse design with robustness to B 0 and B 1 inhomogeneities: A demonstration on 3D T 1-weighted breast MRI at 3 T. Magn Reson Imaging 2020; 75:156-161. [PMID: 33130057 DOI: 10.1016/j.mri.2020.10.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Revised: 10/25/2020] [Accepted: 10/26/2020] [Indexed: 12/01/2022]
Abstract
PURPOSE Spectrally selective fat saturation (FatSat) sequence is commonly used to suppress signal from adipose tissue. Conventional SINC-shaped pulses are sensitive to B0 off-resonance and B1+ offset. Uniform fat saturation with large spatial coverage is especially challenging for the body and breast MRI. The aim of this study is to develop spectrally selective FatSat pulses that offer more immunity to B0/B1+ field inhomogeneities than SINC pulses and evaluate them in bilateral breast imaging at 3 T. MATERIALS AND METHODS Optimized composite pulses (OCP) were designed based on the optimal control theory with robustness to a targeted B0/ B1+ conditions. OCP pulses also allows flexible flip angles to meet different requirements. Comparisons with the vendor-provided SINC pulses were conducted by numerical simulation and in vivo scans using a 3D T1-weighted (T1w) gradient-echo (GRE) sequence with coverage of the whole-breast. RESULTS Simulation revealed that OCP pulses yielded almost half of the transition band and much less sensitivity to B1+ inhomogeneity compared to SINC pulses with B0 off-resonance within ±200 Hz and B1+ scale error within ±0.3 (P < 0.001). Across five normal subjects, OCP FatSat pulses produced 25-41% lower residual fat signals (P < 0.05) with 27-36% less spatial variation (P < 0.05) than SINC. CONCLUSION In contrast to conventional SINC-shaped pulses, the newly designed OCP FatSat pulses mitigated challenges of wide range of B0/ B1+ field inhomogeneities and achieved more uniform fat suppression in bilateral breast T1w imaging at 3 T.
Collapse
Affiliation(s)
- Feng Xu
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA.
| | - Wenbo Li
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Dapeng Liu
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Dan Zhu
- Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Michael Schär
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Kelly Myers
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Qin Qin
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
6
|
Nam JG, Lee JM, Lee SM, Kang HJ, Lee ES, Hur BY, Yoon JH, Kim E, Doneva M. High Acceleration Three-Dimensional T1-Weighted Dual Echo Dixon Hepatobiliary Phase Imaging Using Compressed Sensing-Sensitivity Encoding: Comparison of Image Quality and Solid Lesion Detectability with the Standard T1-Weighted Sequence. Korean J Radiol 2019; 20:438-448. [PMID: 30799575 PMCID: PMC6389821 DOI: 10.3348/kjr.2018.0310] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2018] [Accepted: 09/03/2018] [Indexed: 12/19/2022] Open
Abstract
Objective To compare a high acceleration three-dimensional (3D) T1-weighted gradient-recalled-echo (GRE) sequence using the combined compressed sensing (CS)-sensitivity encoding (SENSE) method with a conventional 3D GRE sequence using SENSE, with respect to image quality and detectability of solid focal liver lesions (FLLs) in the hepatobiliary phase (HBP) of gadoxetic acid-enhanced liver MRI. Materials and Methods A total of 217 patients with gadoxetic acid-enhanced liver MRI at 3T (54 in the preliminary study and 163 in the main study) were retrospectively included. In the main study, HBP imaging was done twice using the standard mDixon-3D-GRE technique with SENSE (acceleration factor [AF]: 2.8, standard mDixon-GRE) and the high acceleration mDixon-3D GRE technique using the combined CS-SENSE technique (CS-SENSE mDixon-GRE). Two abdominal radiologists assessed the two MRI data sets for image quality in consensus. Three other abdominal radiologists independently assessed the diagnostic performance of each data set and its ability to detect solid FLLs in 117 patients with 193 solid nodules and compared them using jackknife alternative free-response receiver operating characteristics (JAFROC). Results There was no significant difference in the overall image quality. CS-SENSE mDixon-GRE showed higher image noise, but lesser motion artifact levels compared with the standard mDixon-GRE (all p < 0.05). In terms of lesion detection, reader-averaged figures-of-merit estimated with JAFROC was 0.918 for standard mDixon-GRE, and 0.953 for CS-SENSE mDixon-GRE (p = 0.142). The non-inferiority of CS-SENSE mDixon-GRE over standard mDixon-GRE was confirmed (difference: 0.064 [−0.012, 0.081]). Conclusion The CS-SENSE mDixon-GRE HBP sequence provided comparable overall image quality and non-inferior solid FFL detectability compared with the standard mDixon-GRE sequence, with reduced acquisition time.
Collapse
Affiliation(s)
- Ju Gang Nam
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea.,Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.
| | - Sang Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Hyo Jin Kang
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Eun Sun Lee
- Department of Radiology, Chung-Ang University Hospital, Seoul, Korea
| | - Bo Yun Hur
- Department of Radiology, National Cancer Center, Goyang, Korea
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - EunJu Kim
- Department of Clinical Science, MR, Philips Healthcare Korea, Seoul, Korea
| | | |
Collapse
|
7
|
He M, Xu J, Sun Z, Wang S, Zhu L, Wang X, Wang J, Feng F, Xue H, Jin Z. Comparison and evaluation of the efficacy of compressed SENSE (CS) and gradient- and spin-echo (GRASE) in breath-hold (BH) magnetic resonance cholangiopancreatography (MRCP). J Magn Reson Imaging 2019; 51:824-832. [PMID: 31313426 DOI: 10.1002/jmri.26863] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 06/22/2019] [Accepted: 06/25/2019] [Indexed: 12/14/2022] Open
Abstract
CONTRACT GRANT SPONSOR Chinese Academy of Medical Sciences (CAMS) Initiative for Innovative Medicine; Contract grant number: 2017-I2M-1-001; Contract grant sponsor: Outstanding Youth Fund of Peking Union Medical College Hospital; Contract grant number: JQ201704; Contract grant sponsor: National Natural Science Foundation of China; Contract grant number: 81871512; Contract grant sponsor: National Public Welfare Basic Scientific Research Program of Chinese Academy of Medical Sciences; Contract grant numbers: 2018PT32003 and 2017PT32004. BACKGROUND Both compressed-sensing (CS) and gradient- and spin-echo (GRASE) sequences can achieve 3D magnetic resonance cholangiopancreatography (MRCP) with a single breath-hold (BH). This work hypothesized that compared with conventional navigator-triggered (NT)-MRCP, the two BH-MRCP protocols, GRASE and CS, may provide better imaging quality, especially for patients with irregular breathing. PURPOSE To evaluate and compare the image quality and diagnostic performance of three MRCP protocols. STUDY TYPE Prospective. SUBJECTS Seventy-four patients suspected to have duct-related pathologies were enrolled. FIELD STRENGTH 3.0T. SEQUENCES NT-MRCP, BH-CS-MRCP, and BH-GRASE-MRCP. ASSESSMENT Breath regularity was evaluated subjectively according to the respiratory waves. The acquisition time was compared. The pancreaticobiliary system was divided into 12 segments and evaluated on a 5-point scale. The diagnostic performance of the three MRCPs was evaluated and compared. STATISTICAL TESTS The Friedman test with a post-hoc test, receiver operating characteristic (ROC) curve analysis, McNemar test, and Kendall's W test were used. RESULTS The BH-MRCP decreased the scan time significantly (P < 0.05). The overall imaging scores of GRASE-MRCP and CS-MRCP were significantly higher than that of NT-MRCP for patients with irregular breathing (4.283 and 4.283 vs. 3.000, both P < 0.05). Compared with NT-MRCP, the diagnostic performance of BH-CS and BH-GRASE MRCP was significantly improved for patients with irregular breathing (AUC = 0.860 and 0.863 vs. 0.572, both P < 0.001). DATA CONCLUSION Compared with conventional NT-MRCP, the overall imaging quality and diagnostic performance of BH-CS and BH-GRASE MRCP were not significantly different for patients with regular breathing and significantly superior for patients with irregular breathing. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:824-832.
Collapse
Affiliation(s)
- Ming He
- The Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medicine Beijing, China
| | - Jin Xu
- The Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medicine Beijing, China
| | - Zhaoyong Sun
- The Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medicine Beijing, China
| | - Shitian Wang
- The Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medicine Beijing, China
| | - Liang Zhu
- The Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medicine Beijing, China
| | | | | | - Feng Feng
- The Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medicine Beijing, China
| | - Huadan Xue
- The Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medicine Beijing, China
| | - Zhengyu Jin
- The Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medicine Beijing, China
| |
Collapse
|
8
|
A Platform for 4-Channel Parallel Transmission MRI at 3 T: Demonstration of Reduced Radiofrequency Heating in a Test Object Containing an Implanted Wire. J Med Biol Eng 2019. [DOI: 10.1007/s40846-019-00478-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
9
|
Ianniello C, Madelin G, Moy L, Brown R. A dual-tuned multichannel bilateral RF coil for 1 H/ 23 Na breast MRI at 7 T. Magn Reson Med 2019; 82:1566-1575. [PMID: 31148249 DOI: 10.1002/mrm.27829] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 05/06/2019] [Accepted: 05/07/2019] [Indexed: 12/25/2022]
Abstract
PURPOSE Sodium MRI has shown promise for monitoring neoadjuvant chemotherapy response in breast cancer. The purpose of this work was to build a dual-tuned bilateral proton/sodium breast coil for 7T MRI that provides sufficient SNR to enable sodium breast imaging in less than 10 minutes. METHODS The proton/sodium coil consists of 2 shielded unilateral units: 1 for each breast. Each unit consists of 3 nested layers: (1) a 3-loop solenoid for sodium excitation, (2) a 3-loop solenoid for proton excitation and signal reception, and (3) a 4-channel receive array for sodium signal reception. Benchmark measurements were performed in phantoms with and without the sodium receive array insert. In vivo images were acquired on a healthy volunteer. RESULTS The sodium receive array boosted 1.5 to 3 times the SNR compared with the solenoid. Proton SNR loss due to residual interaction with the sodium array was less than 10%. The coil enabled sodium imaging in vivo with 2.8-mm isotropic nominal resolution (~5-mm real resolution) in 9:36 minutes. CONCLUSION The coil design that we propose addresses challenges associated with sodium's low SNR from a hardware perspective and offers the opportunity to investigate noninvasively breast tumor metabolism as a function of sodium concentration in patients undergoing neoadjuvant chemotherapy.
Collapse
Affiliation(s)
- Carlotta Ianniello
- Center for Advanced Imaging Innovation and Research (CAI2R) and Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York.,The Sackler Institute of Graduate Biomedical Science, New York University School of Medicine, New York, New York
| | - Guillaume Madelin
- Center for Advanced Imaging Innovation and Research (CAI2R) and Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York.,The Sackler Institute of Graduate Biomedical Science, New York University School of Medicine, New York, New York
| | - Linda Moy
- Center for Advanced Imaging Innovation and Research (CAI2R) and Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York.,The Sackler Institute of Graduate Biomedical Science, New York University School of Medicine, New York, New York
| | - Ryan Brown
- Center for Advanced Imaging Innovation and Research (CAI2R) and Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York.,The Sackler Institute of Graduate Biomedical Science, New York University School of Medicine, New York, New York
| |
Collapse
|
10
|
Chen G, Zhang B, Cloos MA, Sodickson DK, Wiggins GC. A highly decoupled transmit-receive array design with triangular elements at 7T. Magn Reson Med 2018; 80:2267-2274. [PMID: 29572959 DOI: 10.1002/mrm.27186] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2017] [Revised: 02/25/2018] [Accepted: 02/28/2018] [Indexed: 11/10/2022]
Abstract
PURPOSE Transmit arrays are essential tools for various RF shimming or parallel excitation techniques at 7T. Here we present an array design with triangular coils to improve diversity in the B1 profiles in the longitudinal (z) direction and allow for next-nearest neighbor decoupling. METHODS Two cylindrical 8-channel arrays having the same length and diameter, 1 of triangular coils and the other of rectangular coils, were constructed and compared in phantom imaging experiments using measures of excitation distribution for a variety of RF shim settings and geometry factor maps for different accelerations on different planes. RESULTS Coupling between elements was -20 dB or better for all triangular coil pairs, but worse than -12 dB for several of the rectangular coil pairs. Both coils could produce adequate shims on a central transverse plane, but the same shim produced worse results off center for the triangular coil array than for the rectangular coil array. Compared to the rectangular coil array, the maximum geometry factor for the triangular coil array was reduced by a factor of 13.1 when using a 2-fold acceleration in the z-direction. CONCLUSION An array design with triangular coils provides effective decoupling mechanisms for nearest and next-nearest neighboring elements, as well as diversity in B1 profiles along the z-direction, although this also means that individual slices must be shimmed separately. This design is well suited for parallel transmit applications while also having high receive sensitivity.
Collapse
Affiliation(s)
- Gang Chen
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York
| | - Bei Zhang
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York
| | - Martijn A Cloos
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York
| | - Daniel K Sodickson
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York
| | - Graham C Wiggins
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York
| |
Collapse
|
11
|
GRASE Revisited: breath-hold three-dimensional (3D) magnetic resonance cholangiopancreatography using a Gradient and Spin Echo (GRASE) technique at 3T. Eur Radiol 2018; 28:3721-3728. [DOI: 10.1007/s00330-017-5275-0] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 12/13/2017] [Accepted: 12/21/2017] [Indexed: 12/15/2022]
|
12
|
Abe T. B 1 homogeneity of breast MRI using RF shimming with individual specific values in volunteers simulating patients after mastectomy. Acta Radiol 2016; 57:1289-1296. [PMID: 25995312 DOI: 10.1177/0284185115585616] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Magnetic resonance imaging (MRI) using a 3-T MRI scanner is now widely used for clinical examinations. However, B1 inhomogeneity becomes larger with MRI scanners using 3-T and higher. It especially becomes a problem in the breast. To improve B1 homogeneity, a RF shimming technique has been developed. Purpose To evaluate the B1 homogeneity of breast MRI using RF shimming with individual specific values for subjects after mastectomy. Material and Methods The subjects are healthy female volunteers who underwent normal breast imaging, followed by imaging of one breast while the other breast was bound tightly to the chest by bleached cotton cloths (simulating volunteers after mastectomy). B1 mappings were performed with RF shimming using two techniques: (i) optimized fixed value; and (ii) individual specific values using a 3-T MRI scanner. The means and standard deviations of the B1 maps for all slices in the breast were measured and compared between the fixed value and the individual specific value cases. Results For normal volunteers, the breast B1 variation was not statistically significantly different between the RF shimming techniques. For volunteers after simulated surgery, the breast B1 variation was (1.02 ± 0.29) with the fixed value and (0.98 ± 0.22) with the individual specific value ( P < 0.01). With the individual specific optimization, B1 variation for all slices in the breast was improved for volunteers after simulated surgery. Conclusion RF shimming with individual specific values has the potential to improve the B1 homogeneity of breast MRI in patients after mastectomy.
Collapse
Affiliation(s)
- Takayuki Abe
- National Institute of Radiological Sciences, Inage, Chiba, Japan
| |
Collapse
|
13
|
Padormo F, Beqiri A, Hajnal JV, Malik SJ. Parallel transmission for ultrahigh-field imaging. NMR IN BIOMEDICINE 2016; 29:1145-61. [PMID: 25989904 PMCID: PMC4995736 DOI: 10.1002/nbm.3313] [Citation(s) in RCA: 115] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2014] [Revised: 03/27/2015] [Accepted: 03/29/2015] [Indexed: 05/24/2023]
Abstract
The development of MRI systems operating at or above 7 T has provided researchers with a new window into the human body, yielding improved imaging speed, resolution and signal-to-noise ratio. In order to fully realise the potential of ultrahigh-field MRI, a range of technical hurdles must be overcome. The non-uniformity of the transmit field is one of such issues, as it leads to non-uniform images with spatially varying contrast. Parallel transmission (i.e. the use of multiple independent transmission channels) provides previously unavailable degrees of freedom that allow full spatial and temporal control of the radiofrequency (RF) fields. This review discusses the many ways in which these degrees of freedom can be used, ranging from making more uniform transmit fields to the design of subject-tailored RF pulses for both uniform excitation and spatial selection, and also the control of the specific absorption rate. © 2015 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- Francesco Padormo
- Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
| | - Arian Beqiri
- Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
| | - Joseph V Hajnal
- Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
- Centre for the Developing Brain, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
| | - Shaihan J Malik
- Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
| |
Collapse
|
14
|
Bedair R, Graves MJ, Patterson AJ, McLean MA, Manavaki R, Wallace T, Reid S, Mendichovszky I, Griffiths J, Gilbert FJ. Effect of Radiofrequency Transmit Field Correction on Quantitative Dynamic Contrast-enhanced MR Imaging of the Breast at 3.0 T. Radiology 2016; 279:368-77. [PMID: 26579563 DOI: 10.1148/radiol.2015150920] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To investigate the effects of radiofrequency transmit field (B1(+)) correction on (a) the measured T1 relaxation times of normal breast tissue and malignant lesions and (b) the pharmacokinetically derived parameters of malignant breast lesions at 3 T. MATERIALS AND METHODS Ethics approval and informed consent were obtained. Between May 2013 and January 2014, 30 women (median age, 58 years; range, 32-83 years) with invasive ductal carcinoma of at least 10 mm were recruited to undergo dynamic contrast material-enhanced magnetic resonance (MR) imaging before surgery. B1(+) and T1 mapping sequences were performed to determine the effect of B1(+) correction on the native tissue relaxation time (T10) of fat, parenchyma, and malignant lesions in both breasts. Pharmacokinetic parameters were calculated before and after correction for B1(+) variations. Results were correlated with histologic grade by using the Kruskal-Wallis test. RESULTS Measurements showed a mean 37% flip angle difference between the right and left breast, which resulted in a 61% T10 difference in fat and a 41.5% difference in parenchyma between the two breasts. The T1 of lesions in the right breast increased by 58%, whereas that of lesions in the left breast decreased by 30% after B1(+) correction. The whole-tumor transendothelial permeability across the vascular compartment(K(trans)) of lesions in the right breast decreased by 41%, and that of lesions in the left breast increased by 46% after correction. A systematic increase in K(trans) was observed, with significant differences found across the histologic grades (P < .001). The effect size of B1(+) correction on K(trans) calculation was large for lesions in the right breast and moderate for lesions in the left breast (Cohen effect size, d = 0.86 and d = 0.59, respectively). CONCLUSION B1(+) correction demonstrates a substantial effect on the results of quantitative dynamic contrast-enhanced analysis of breast tissue at 3 T, which propagates into the pharmacokinetic analysis of tumors that is dependent on whether the tumor is located in the right or left breast.
Collapse
Affiliation(s)
- Reem Bedair
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| | - Martin J Graves
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| | - Andrew J Patterson
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| | - Mary A McLean
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| | - Roido Manavaki
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| | - Tess Wallace
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| | - Scott Reid
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| | - Iosif Mendichovszky
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| | - John Griffiths
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| | - Fiona J Gilbert
- From the Department of Radiology, School of Clinical Medicine, University of Cambridge, Box 218, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, England (R.B., M.J.G., R.M., T.W., I.M., F.J.G.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Cambridge, England (M.J.G., A.J.P., M.A.M.); Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Cambridge, England (M.A.M., J.G.); and General Electric Company, GE Medical Systems Limited, Chalfont St Giles, England (S.R.)
| |
Collapse
|
15
|
Koh DM, Lee JM, Bittencourt LK, Blackledge M, Collins DJ. Body Diffusion-weighted MR Imaging in Oncology: Imaging at 3 T. Magn Reson Imaging Clin N Am 2016; 24:31-44. [PMID: 26613874 DOI: 10.1016/j.mric.2015.08.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Advances in hardware and software enable high-quality body diffusion-weighted images to be acquired for oncologic assessment. 3.0 T affords improved signal/noise for higher spatial resolution and smaller field-of-view diffusion-weighted imaging (DWI). DWI at 3.0 T can be applied as at 1.5 T to improve tumor detection, disease characterization, and the assessment of treatment response. DWI at 3.0 T can be acquired on a hybrid PET-MR imaging system, to allow functional MR information to be combined with molecular imaging.
Collapse
Affiliation(s)
- Dow-Mu Koh
- Department of Radiology, Royal Marsden Hospital, Downs Road, Sutton, SM2 5PT, UK.
| | - Jeong-Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, South Korea
| | - Leonardo Kayat Bittencourt
- Department of Radiology, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil; CDPI and Multi-Imagem Clinics, Rio de Janeiro, Brazil
| | | | | |
Collapse
|
16
|
Pineda FD, Medved M, Fan X, Karczmar GS. B1 and T1 mapping of the breast with a reference tissue method. Magn Reson Med 2015; 75:1565-73. [PMID: 26014575 DOI: 10.1002/mrm.25751] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Revised: 03/20/2015] [Accepted: 04/03/2015] [Indexed: 11/07/2022]
Abstract
PURPOSE To develop a method for mapping the B1 field using a reference signal from a tissue with known T1. METHODS Flip angle correction factors were calculated in a region with a known "gold standard" T1; by comparing T1 values from a variable flip angle (VFA) sequence to the "gold standard" and correcting the value of the Ernst angle. The resulting partial B1 map was interpolated for all other regions. In the breast, fat is an ideal reference tissue because its T1 is spatially homogeneous and interpatient variability is low. This method was tested with scans of phantoms and patients (n = 4) on a 3T magnet. The performance of the method was evaluated by comparing the results of VFA T1 mapping with and without B1 correction to inversion recovery (IR) T1 maps. RESULTS Phantom data determined that a linear inverse distance weighted interpolation accurately recovered the full B1 map. Use of interpolated maps to correct the VFA data in vivo, reduced the average difference in the T1 of parenchyma between VFA and IR results from 58% to 8%. CONCLUSION This proof-of-principle study showed that it is possible to recover a full and accurate map of the B1 field in the breast by using a reference tissue (fat) with an accurately measured T1.
Collapse
Affiliation(s)
- Federico D Pineda
- Department of Radiology, University of Chicago, Chicago, Illinois, USA
| | - Milica Medved
- Department of Radiology, University of Chicago, Chicago, Illinois, USA
| | - Xiaobing Fan
- Department of Radiology, University of Chicago, Chicago, Illinois, USA
| | | |
Collapse
|
17
|
Pineda FD, Medved M, Fan X, Ivancevic MK, Abe H, Shimauchi A, Newstead GM, Karczmar GS. Comparison of dynamic contrast-enhanced MRI parameters of breast lesions at 1.5 and 3.0 T: a pilot study. Br J Radiol 2015; 88:20150021. [PMID: 25785918 DOI: 10.1259/bjr.20150021] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
OBJECTIVE To compare dynamic contrast-enhanced (DCE) MRI parameters from scans of breast lesions at 1.5 and 3.0 T. METHODS 11 patients underwent paired MRI examinations in both Philips 1.5 and 3.0 T systems (Best, Netherlands) using a standard clinical fat-suppressed, T1 weighted DCE-MRI protocol, with 70-76 s temporal resolution. Signal intensity vs time curves were fit with an empirical mathematical model to obtain semi-quantitative measures of uptake and washout rates as well as time-to-peak enhancement (TTP). Maximum percent enhancement and signal enhancement ratio (SER) were also measured for each lesion. Percent differences between parameters measured at the two field strengths were compared. RESULTS TTP and SER parameters measured at 1.5 and 3.0 T were similar; with mean absolute differences of 19% and 22%, respectively. Maximum percent signal enhancement was significantly higher at 3 T than at 1.5 T (p = 0.006). Qualitative assessment showed that image quality was significantly higher at 3 T (p = 0.005). CONCLUSION Our results suggest that TTP and SER are more robust to field strength change than other measured kinetic parameters, and therefore measurements of these parameters can be more easily standardized than measurements of other parameters derived from DCE-MRI. Semi-quantitative measures of overall kinetic curve shape showed higher reproducibility than do discrete classification of kinetic curve early and delayed phases in a majority of the cases studied. ADVANCES IN KNOWLEDGE Qualitative measures of curve shape are not consistent across field strength even when acquisition parameters are standardized. Quantitative measures of overall kinetic curve shape, by contrast, have higher reproducibility.
Collapse
Affiliation(s)
- F D Pineda
- 1 Department of Radiology, University of Chicago, Chicago, IL, USA
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Evaluation of Kinetic Entropy of Breast Masses Initially Found on MRI using Whole-lesion Curve Distribution Data: Comparison with the Standard Kinetic Analysis. Eur Radiol 2015; 25:2470-8. [DOI: 10.1007/s00330-015-3635-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2014] [Revised: 12/11/2014] [Accepted: 01/21/2015] [Indexed: 12/22/2022]
|
19
|
Fat suppression techniques (STIR vs. SPAIR) on diffusion-weighted imaging of breast lesions at 3.0 T: preliminary experience. Radiol Med 2015; 120:705-13. [PMID: 25665796 DOI: 10.1007/s11547-015-0508-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2013] [Accepted: 05/19/2014] [Indexed: 12/24/2022]
Abstract
PURPOSE The aim of this work was to perform a qualitative and quantitative comparison of the performance of two fat suppression techniques on breast diffusion-weighted imaging (DWI). MATERIALS AND METHODS Fifty-one women underwent clinical breast magnetic resonance imaging, including DWI with short TI inversion recovery (STIR) and spectral attenuated inversion recovery (SPAIR). Four were excluded from the analysis due to image artefacts. Rating of fat suppression uniformity and lesion visibility were performed. Agreement between the two sequences was evaluated. Additionally, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values for normal gland, benign and malignant lesions were compared. Receiver operating characteristic analysis was also performed. RESULTS From the 52 lesions found, 47 were detected by both sequences. DWI-STIR evidenced more homogeneous fat suppression (p = 0.03). Although these lesions were seen with both techniques, DWI-SPAIR evidenced higher score for lesion visibility in nine of them. SNR and CNR were comparable, except for SNR in benign lesions (p < 0.01), which was higher for DWI-SPAIR. Mean ADC values for lesions were similar. ADC for normal fibroglandular tissue was higher when using DWI-STIR (p = 0.006). Sensitivity, specificity, accuracy and area under the curve values were alike: 84.0 % for both; 77.3, 71.4 %; 80.9, 78.3 %; 82.5, 81.3 % for DWI-SPAIR and DWI-STIR, respectively. CONCLUSION DWI-STIR showed superior fat suppression homogeneity. No differences were found for SNR and CNR, except for SNR in benign lesions. ADCs for lesions were comparable. Findings in this study are consistent with previous studies at 1.5 T, meaning that both fat suppression techniques are appropriate for breast DWI at 3.0 T.
Collapse
|
20
|
Jogiya R, Schuster A, Zaman A, Motwani M, Kouwenhoven M, Nagel E, Kozerke S, Plein S. Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience. J Cardiovasc Magn Reson 2014; 16:90. [PMID: 25429993 PMCID: PMC4247198 DOI: 10.1186/s12968-014-0090-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2014] [Accepted: 10/30/2014] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND The purpose of this study was to establish the feasibility of three-dimensional (3D) balanced steady-state-free-precession (bSSFP) myocardial perfusion cardiovascular magnetic resonance (CMR) at 3T using local RF shimming with dual-source RF transmission, and to compare it with spoiled gradient echo (TGRE) acquisition. METHODS Dynamic contrast-enhanced 3D bSSFP perfusion imaging was performed on a 3T MRI scanner equipped with dual-source RF transmission technology. Images were reconstructed using k-space and time broad-use linear acquisition speed-up technique (k-t BLAST) and compartment based principle component analysis (k-t PCA). RESULTS In phantoms and volunteers, local RF shimming with dual source RF transmission significantly improved B1 field homogeneity compared with single source transmission (P=0.01). 3D bSSFP showed improved signal-to-noise, contrast-to-noise and signal homogeneity compared with 3D TGRE (29.8 vs 26.9, P=0.045; 23.2 vs 21.6, P=0.049; 14.9% vs 12.4%, p=0.002, respectively). Image quality was similar between bSSFP and TGRE but there were more dark rim artefacts with bSSFP. k-t PCA reconstruction reduced artefacts for both sequences compared with k-t BLAST. In a subset of five patients, both methods correctly identified those with coronary artery disease. CONCLUSION Three-dimensional bSSFP myocardial perfusion CMR using local RF shimming with dual source parallel RF transmission at 3T is feasible and improves signal characteristics compared with TGRE. Image artefact remains an important limitation of bSSFP imaging at 3T but can be reduced with k-t PCA.
Collapse
Affiliation(s)
- Roy Jogiya
- />King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, SE1 7EH UK
| | - Andreas Schuster
- />King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, SE1 7EH UK
- />Department of Cardiology and Pneumology and German Centre for Cardiovascular Research (DZHK, Partner Site Göttingen), Georg-August-University, Göttingen, Germany
| | - Arshad Zaman
- />Multidisciplinary Cardiovascular Research Centre & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT UK
| | - Manish Motwani
- />Multidisciplinary Cardiovascular Research Centre & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT UK
| | | | - Eike Nagel
- />King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, SE1 7EH UK
| | - Sebastian Kozerke
- />King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, SE1 7EH UK
- />Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Sven Plein
- />King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, SE1 7EH UK
- />Multidisciplinary Cardiovascular Research Centre & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT UK
| |
Collapse
|
21
|
Bilateral breast MRI by use of dual-source parallel radiofrequency excitation and image-based shimming at 3 Tesla: improvement in homogeneity on fat-suppression imaging. Radiol Phys Technol 2014; 8:4-12. [DOI: 10.1007/s12194-014-0278-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2014] [Revised: 06/09/2014] [Accepted: 06/09/2014] [Indexed: 12/24/2022]
|
22
|
Pang Y, Yu B, Vigneron DB, Zhang X. Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging. Quant Imaging Med Surg 2014; 4:11-8. [PMID: 24649430 DOI: 10.3978/j.issn.2223-4292.2014.02.03] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2014] [Accepted: 02/14/2014] [Indexed: 11/14/2022]
Abstract
Quadrature coils are often desired in MR applications because they can improve MR sensitivity and also reduce excitation power. In this work, we propose, for the first time, a quadrature array design strategy for parallel transmission at 298 MHz using single-feed circularly polarized (CP) patch antenna technique. Each array element is a nearly square ring microstrip antenna and is fed at a point on the diagonal of the antenna to generate quadrature magnetic fields. Compared with conventional quadrature coils, the single-feed structure is much simple and compact, making the quadrature coil array design practical. Numerical simulations demonstrate that the decoupling between elements is better than -35 dB for all the elements and the RF fields are homogeneous with deep penetration and quadrature behavior in the area of interest. Bloch equation simulation is also performed to simulate the excitation procedure by using an 8-element quadrature planar patch array to demonstrate its feasibility in parallel transmission at the ultrahigh field of 7 Tesla.
Collapse
Affiliation(s)
- Yong Pang
- 1 Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA ; 2 Magwale, Palo Alto, CA, USA ; 3 UCSF/UC Berkeley Joint Bioengineering Program, San Francisco & Berkeley, CA, USA
| | - Baiying Yu
- 1 Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA ; 2 Magwale, Palo Alto, CA, USA ; 3 UCSF/UC Berkeley Joint Bioengineering Program, San Francisco & Berkeley, CA, USA
| | - Daniel B Vigneron
- 1 Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA ; 2 Magwale, Palo Alto, CA, USA ; 3 UCSF/UC Berkeley Joint Bioengineering Program, San Francisco & Berkeley, CA, USA
| | - Xiaoliang Zhang
- 1 Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA ; 2 Magwale, Palo Alto, CA, USA ; 3 UCSF/UC Berkeley Joint Bioengineering Program, San Francisco & Berkeley, CA, USA
| |
Collapse
|
23
|
Jiang L, Zhou Y, Zhou C, Chen M, Dai Y, Fu Y, Zhao X. Dual-source parallel radiofrequency transmission for magnetic resonance breast imaging at 3T: any added clinical value? Magn Reson Imaging 2014; 32:523-8. [PMID: 24582548 DOI: 10.1016/j.mri.2014.01.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2013] [Revised: 01/12/2014] [Accepted: 01/14/2014] [Indexed: 11/25/2022]
Abstract
PURPOSE To investigate the influence of dual-source parallel radiofrequency (RF) excitation on clinical breast MR images. METHODS A 3T MR system with both dual-source and conventional single-source RF excitations was used to examine 22 patients. Axial TSE-T2WI with fat suppression, TSE-T1WI without fat suppression, THRIVE (3D field echo) and DWI (SE-EPI) were obtained by using both excitation techniques. Image homogeneity, image contrast and lesion conspicuity were measured or independently scored by two radiologists and were compared by paired-sample t test or Wilcoxon test. RESULTS Both excitations revealed 24 lesions. For SE sequences using dual-source mode, image homogeneity was improved (P=0.00), scan time was reduced, and ghost artifacts on DWI were significantly reduced (P=0.00). However, image contrast was not increased and lesion conspicuity had no significant difference between two modes, except DWI on which lesion conspicuity was significantly improved (P=0.00), due to less ghost artifacts. For field-echo sequence, image homogeneity, acquisition time, image contrast and lesion conspicuity had no significant difference between the two modes. CONCLUSIONS Dual-source parallel RF transmission has some added value for improving breast image quality. However, its value is limited in terms of improving lesion detection and characterization.
Collapse
Affiliation(s)
- Lei Jiang
- Radiology Department, Beijing Hospital, the Fifth Affiliated College of Peking University, Beijing, China
| | - Yiming Zhou
- Radiology Department, Beijing Chaoyang Hospital, the Affiliated College of Capital Medical University, Beijing, China
| | - Cheng Zhou
- Radiology Department, Beijing Hospital, the Fifth Affiliated College of Peking University, Beijing, China
| | - Min Chen
- Radiology Department, Beijing Hospital, the Fifth Affiliated College of Peking University, Beijing, China.
| | | | - Yuan Fu
- Radiology Department, Beijing Hospital, the Fifth Affiliated College of Peking University, Beijing, China
| | - Xuna Zhao
- Philips Healthcare, Andover, MA, USA
| |
Collapse
|
24
|
DeMartini WB, Rahbar H. Breast magnetic resonance imaging technique at 1.5 T and 3 T: requirements for quality imaging and American College of Radiology accreditation. Magn Reson Imaging Clin N Am 2014; 21:475-82. [PMID: 23928238 DOI: 10.1016/j.mric.2013.04.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Although there are multiple variations in acquisition protocols for breast magnetic resonance (MR) imaging, there is agreement that components of high-quality technique include a bilateral acquisition obtained with a dedicated breast coil. Further, key pulse sequences should be included and spatial and temporal resolution should be sufficiently high to assess lesion morphology and kinetics. Artifacts must be recognized and avoided. The American College of Radiology Breast MRI Accreditation Program requirements provide minimum standards to guide facilities in technique. MR imaging at 3 T is increasingly available and offers signal-to-noise ratio advantages over 1.5 T but also some technical challenges.
Collapse
Affiliation(s)
- Wendy B DeMartini
- Department of Radiology, University of Washington School of Medicine and the Seattle Cancer Care Alliance, Seattle, WA 98109-1023, USA.
| | | |
Collapse
|
25
|
Yoon JH, Lee JM, Yu MH, Kim EJ, Han JK, Choi BI. High-resolution T1-weighted gradient echo imaging for liver MRI using parallel imaging at high-acceleration factors. ACTA ACUST UNITED AC 2014; 39:711-21. [DOI: 10.1007/s00261-014-0099-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
26
|
Sprinkart AM, Nehrke K, Träber F, Block W, Gieseke J, Schmitz G, Willinek WA, Schild H, Börnert P. Ultrafast volumetric B1+mapping for improved radiofrequency shimming in 3 tesla body MRI. J Magn Reson Imaging 2013; 40:857-63. [DOI: 10.1002/jmri.24438] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2013] [Accepted: 09/07/2013] [Indexed: 11/09/2022] Open
Affiliation(s)
- Alois M. Sprinkart
- Department of Radiology; University of Bonn; Germany
- Institute of Medical Engineering; Ruhr-University Bochum; Germany
| | - Kay Nehrke
- Philips Research Laboratory; Hamburg Germany
| | - Frank Träber
- Department of Radiology; University of Bonn; Germany
| | | | | | - Georg Schmitz
- Institute of Medical Engineering; Ruhr-University Bochum; Germany
| | | | - Hans Schild
- Department of Radiology; University of Bonn; Germany
| | - Peter Börnert
- Philips Research Laboratory; Hamburg Germany
- Department of Radiology; LUMC; Leiden The Netherlands
| |
Collapse
|
27
|
Rahbar H, Partridge SC, DeMartini WB, Thursten B, Lehman CD. Clinical and technical considerations for high quality breast MRI at 3 Tesla. J Magn Reson Imaging 2013; 37:778-90. [PMID: 23526757 DOI: 10.1002/jmri.23834] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2012] [Accepted: 08/22/2012] [Indexed: 11/10/2022] Open
Abstract
The use of breast MRI at 3 tesla (T) has increased in use substantially in recent years. Potential benefits of moving to higher field strength MRI include improved morphologic and kinetic assessment of breast lesions through higher spatial and temporal resolution dynamic contrast-enhanced MR examinations. Furthermore, higher field strength holds promise for the development of superior advanced breast MRI techniques, such as diffusion weighted imaging and MR spectroscopy. To fully realize the benefits of moving to 3T, a thorough understanding of the technical and safety challenges of higher field strength imaging specific to breast MRI is paramount. Through the use of advanced coil technology, parallel imaging, dual-source parallel radiofrequency excitation, and image-based shimming techniques, many of these limiting technical factors can be overcome to achieve high quality breast MRI at 3T.
Collapse
Affiliation(s)
- Habib Rahbar
- Department of Radiology, University of Washington, Seattle Cancer Care Alliance, Seattle, Washington 98109-1023, USA.
| | | | | | | | | |
Collapse
|
28
|
Park JE, Lee JE, Hwang JY, Cha ES. An imaging protocol for dynamic contrast-enhanced breast MRI with 3.0T: using sagittal sequence interleaved between axial sequences. Acta Radiol 2013; 54:608-13. [PMID: 23486561 DOI: 10.1177/0284185113478006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
BACKGROUND B1 transmission-field inhomogeneity has been reported at 3.0 Tesla (T) breast imaging. Enhancement measurements of breast cancers at 3.0T may be insufficient for some patients and improvements in imaging protocols are needed. PURPOSE To quantify B1 inhomogeneities in normal tissue and malignant masses at 3.0T breast MR imaging and to evaluate effect of an imaging protocol using an interleaved sagittal sequence in dynamic contrast-enhanced MRI (DCE-MRI). MATERIAL AND METHODS A total of 76 patients were included who underwent DCE-MRI of the breast at 3.0T with an imaging protocol consisting of 1st, 2nd, and 4-6th bilateral axial sequences, and 3rd and 7th unilateral sagittal sequences. Signal intensity (SI) of normal breast tissue was measured at nipple level in four bilateral locations (anterior, posterior, medial, and lateral). Mean whole breast and location specific SI were calculated and compared between right and left breast using a paired t-test. All malignant masses were classified into three groups according to tumor size on MRI (≤2 cm, 2-4 cm, >4 cm). SI of malignant masses was measured independently on axial and sagittal sequences. The axial-sagittal SI gap in each mass was calculated and difference between right and left breast was compared using the t test. Size of each malignant mass was compared with pathologic findings to assess performance of the imaging protocol. RESULTS SI of normal breast tissue were lower for the right breast (R-L difference, -91.9; P < 0.0001) and in all four locations (anterior, P < 0.01; posterior, P < 0.01; medial, P < 0.0001; lateral, P < 0.0001). SI of malignant masses were lower for the right breast among same size of the lesions (P < 0.0001), particularly < 4 cm (P < 0.0001). Decreased right to left difference in SI was produced with an interleaved sagittal sequence, as axial-sagittal gap of malignant masses was significant when tumor locates on the right side (P < 0.001). The concordance rate in predicting size of mass in this imaging protocol was 92.2%. CONCLUSION The interleaved sagittal sequence is helpful to adjust reduced SI of malignant masses on right breast at 3.0T. This imaging protocol is clinically applicable by adding a single sequence during DCE-MRI of the breast.
Collapse
Affiliation(s)
- Ji Eun Park
- Department of Radiology, Ewha Womans University School of Medicine, Seoul
| | - Jee Eun Lee
- Department of Radiology, Ewha Womans University School of Medicine, Seoul
| | - Ji-Young Hwang
- Department of Radiology, Kangnam Sacred Hospital, Hallym University, Seoul, Korea
| | - Eun Suk Cha
- Department of Radiology, Ewha Womans University School of Medicine, Seoul
| |
Collapse
|
29
|
Trop I, Gilbert G, Ivancevic MK, Beaudoin G. Breast MR imaging at 3 T with dual-source radiofrequency transmission offers superior B1 homogeneity: an intraindividual comparison with breast MR imaging at 1.5 T. Radiology 2013; 267:602-8. [PMID: 23401582 DOI: 10.1148/radiol.13121388] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate and compare B1 homogeneity for breast magnetic resonance (MR) imaging performed at 3 T with dual-source radiofrequency (RF) transmission to 1.5-T MR imaging and 3-T MR imaging with quadrature transmission. MATERIALS AND METHODS This prospective study received institutional review board approval and patients provided informed consent. Women (n = 25; mean age, 53 years; range, 30-68 years) suspected of having breast lesions underwent breast MR imaging examinations on comparable 1.5-T and 3-T clinical systems between February and May 2012. B1 maps were obtained at 1.5 T and at 3 T with quadrature and dual-source RF transmission. Intrabreast differences and differences in mean B1 values between right and left breasts were investigated by using two-sided multivariate analysis of variance with interaction; t tests were used to compare the differences between measured whole-breast mean B1 values and requested B1 values. RESULTS With quadrature transmission at 1.5 T and 3 T, the mean B1 values showed a statistically significant difference: left-breast measured B1 was -8.9% of requested B1 value at 1.5 T and -13.7% at 3 T (P < .001), whereas right-breast measured B1 was +5.4% of requested B1 value at 1.5 T (P < .001) and +2.7% at 3 T (P = .01). With dual-source RF transmission at 3 T, mean B1 values across the breasts were not statistically different, nor were the measured B1 values compared with requested B1 values (left breast, -0.6%; right breast, -0.7%). At 3 T with dual-source transmission, slight intrabreast local variations in B1 were recorded. CONCLUSION MR imaging at 3 T with dual-source RF transmission offered an overall B1 homogeneity for breast imaging that was better than that obtained at 1.5 T and with quadrature transmission.
Collapse
Affiliation(s)
- Isabelle Trop
- Radiology Department, Breast Imaging Centre, 3è Le Royer, Centre Hospitalier de l'Université de Montréal, Hôtel-Dieu de Montréal, 3840 Saint-Urbain, Montreal, QC, Canada H2W 1T8.
| | | | | | | |
Collapse
|
30
|
Sung K, Daniel BL, Hargreaves BA. Transmit B1+ field inhomogeneity and T1 estimation errors in breast DCE-MRI at 3 tesla. J Magn Reson Imaging 2013; 38:454-9. [PMID: 23292822 DOI: 10.1002/jmri.23996] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2012] [Accepted: 11/19/2012] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To quantify B1+ variation across the breasts and to evaluate the accuracy of precontrast T1 estimation with and without B1+ variation in breast MRI patients at 3 Tesla (T). MATERIALS AND METHODS B1+ and variable flip angle (VFA) T1 mapping were included in our dynamic contrast-enhanced (DCE) breast imaging protocol to study a total of 25 patients on a 3.0T GE MR 750 system. We computed precontrast T1 relaxation in fat, which we assumed to be consistent across a cohort of breast imaging subjects, with and without compensation for B1+ variation. The mean and standard deviation of B1+ and T1 values were calculated for statistical data analysis. RESULTS Our measurements showed a consistent B1+ field difference between the left and right breasts. The left breast has an average 15.4% higher flip angle than the prescribed flip angle, and the right breast has an average 17.6% lower flip angle than the prescribed flip angle. This average 33% flip angle difference, which can be vendor and model specific, creates a 52% T1 estimation bias in fat between breasts using the VFA T1 mapping technique. The T1 variation is reduced to 7% by including B1+ correction. CONCLUSION We have shown that severe B1+ variation over the breasts can cause a substantial error in T1 estimation between the breasts, in VFA T1 maps at 3T, but that compensating for these variations can considerably improve accuracy of T1 measurements, which can directly benefit quantitative breast DCE-MRI at 3T.
Collapse
Affiliation(s)
- Kyunghyun Sung
- Department of Radiology, Stanford University, Stanford, CA 90095, USA.
| | | | | |
Collapse
|
31
|
Kalemis A, Delattre BMA, Heinzer S. Sequential whole-body PET/MR scanner: concept, clinical use, and optimisation after two years in the clinic. The manufacturer’s perspective. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2012; 26:5-23. [DOI: 10.1007/s10334-012-0330-y] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2012] [Revised: 07/10/2012] [Accepted: 07/11/2012] [Indexed: 01/08/2023]
|