1
|
Huang Q, Tian Y, Mendes J, Ranjan R, Adluru G, DiBella E. Quantitative myocardial perfusion with a hybrid 2D simultaneous multi-slice sequence. Magn Reson Imaging 2023; 98:7-16. [PMID: 36563888 PMCID: PMC10474933 DOI: 10.1016/j.mri.2022.12.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 12/17/2022] [Indexed: 12/24/2022]
Abstract
PURPOSE To evaluate a novel 2D simultaneous multi-slice (SMS) myocardial perfusion acquisition and compare directly to a published quantitative 3D stack-of-stars (SoS) acquisition. METHODS A hybrid saturation recovery radial 2D SMS sequence following a single saturation was created for the quantification of myocardial blood flow (MBF). This sequence acquired three slices simultaneously and generated an arterial input function (AIF) using the first 24 rays. Validation was done in a novel way by alternating heartbeats between the hybrid 2D SMS and the 3D SoS acquisitions. Initial studies were done to study the effects of using only every other beat for the 2D SMS in two subjects, and for the 3D SoS in four subjects. The proposed alternating acquisitions were then performed in ten dog studies at rest, four dog studies at adenosine stress, and two human resting studies. Quantitative MBF analysis was performed for 2D SMS and 3D SoS separately, using a compartment model. RESULTS Acquiring every-other-beat data resulted in 6 ± 5% ("ideal") and 11 ± 8% ("practical") perfusion changes for both 2D SMS and 3D SoS methods. For alternating acquisitions, 2D SMS and 3D SoS quantitative perfusion values were comparable for both the twelve rest studies (2D SMS: 0.69 ± 0.16 vs 3D: 0.69 ± 0.15 ml/g/min, p = 0.55) and the four stress studies (2D SMS: 1.28 ± 0.22 vs 3D: 1.30 ± 0.24 ml/g/min, p = 0.61). CONCLUSION Every-other-beat acquisition changed estimated perfusion values relatively little for both sequences. The quantitative hybrid radial 2D SMS myocardial first-pass perfusion imaging sequence gave results similar to 3D perfusion when compared directly with an alternating beat acquisition.
Collapse
Affiliation(s)
- Qi Huang
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.
| | - Ye Tian
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, USA
| | - Jason Mendes
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Ravi Ranjan
- Division of Cardiovascular Medicine, University of Utah, Salt Lake City, UT, USA
| | - Ganesh Adluru
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Edward DiBella
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
2
|
He B, Chen Y, Wang L, Yang Y, Xia C, Zheng J, Gao F. Compact MR-compatible ergometer and its application in cardiac MR under exercise stress: A preliminary study. Magn Reson Med 2022; 88:1927-1936. [PMID: 35649186 PMCID: PMC9545047 DOI: 10.1002/mrm.29311] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 04/29/2022] [Accepted: 05/02/2022] [Indexed: 02/05/2023]
Abstract
Purpose To develop a compact MR‐compatible ergometer for exercise stress and to initially evaluate the reproducibility of myocardial native T1 and myocardial blood flow (MBF) measurements during exercise stress performed on this ergometer. Methods The compact ergometer consists of exercise, workload, and data processing components. The exercise stress can be achieved by pedaling on a pair of cylinders at a predefined frequency with adjustable resistances. Ten healthy subjects were recruited to perform cardiac MRI scans twice in a 3.0T MR scanner, at different days to assess reproducibility. Myocardial native T1 and MBF were acquired at rest and during a moderate exercise. The reproducibility of the two tests was determined by the intra‐group correlation coefficient (ICC) and coefficient of variation (CoV). Results The mean exercise intensity in this pilot study was 45 Watts (W), with an exercise duration of 5 min. Stress induced a significant increase in systolic blood pressure (from 113 ± 11 mmHg to 141 ± 12, P < 0.05) and maximal increase in heart rate by 74 ± 19%. The rate pressure product increased two‐fold (P < 0.001). Excellent reproducibility was demonstrated in native T1 during the exercise (CoV = 3.0%), whereas the reproducibility of MBF and myocardial perfusion reserve during the exercise was also good (CoV = 10.7% and 8.8%, respectively). Conclusion This pilot study demonstrated that it is possible to acquire reproducible measurements of myocardial native T1 and MBF during the exercise stress in healthy volunteers using our new compact ergometer. Click here for author‐reader discussions
Collapse
Affiliation(s)
- Bo He
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China.,Molecular Imaging Center, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Yushu Chen
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Lei Wang
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China.,Molecular Imaging Center, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Yang Yang
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Chunchao Xia
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Jie Zheng
- Mallinckrodt Institute of Radiology, Washington University in St Louis, St. Louis, Missouri, USA
| | - Fabao Gao
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China.,Molecular Imaging Center, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
3
|
Kero T, Johansson E, Engström M, Eggers KM, Johansson L, Ahlström H, Lubberink M. Evaluation of quantitative CMR perfusion imaging by comparison with simultaneous 15O-water-PET. J Nucl Cardiol 2021; 28:1252-1266. [PMID: 31313066 PMCID: PMC8421320 DOI: 10.1007/s12350-019-01810-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Accepted: 05/28/2019] [Indexed: 02/04/2023]
Abstract
BACKGROUND We assessed the quantitative accuracy of cardiac perfusion measurements using dynamic contrast-enhanced MRI with simultaneous 15O-water PET as reference with a fully integrated PET-MR scanner. METHODS 15 patients underwent simultaneous DCE MRI and 15O-water PET scans at rest and adenosine-stress on an integrated PET-MR scanner. Correlation and agreement between MRI- and PET-based global and regional MBF values were assessed using correlation and Bland-Altman analysis. RESULTS Three subjects were excluded due to technical problems. Global mean (± SD) MBF values at rest and stress were 0.97 ± 0.27 and 3.19 ± 0.70 mL/g/min for MRI and 1.02 ± 0.28 and 3.13 ± 1.16 mL/g/min for PET (P = 0.66 and P = 0.81). The correlations between global and regional MRI- and PET-based MBF values were strong (r = 0.86 and r = 0.75). The biases were negligible for both global and regional MBF comparisons (0.01 and 0.00 mL/min/g for both), but the limits of agreement were wide for both global and regional MBF, with larger variability for high MBF-values. CONCLUSION The correlation between simultaneous MBF measurements with DCE MRI and 15O-water PET measured in an integrated PET-MRI was strong but the agreement was only moderate indicating that MRI-based quantitative MBF measurements is not ready for clinical introduction.
Collapse
Affiliation(s)
- Tanja Kero
- Medical Imaging Centre, Uppsala University Hospital, 75185, Uppsala, Sweden.
- Department of Surgical Sciences/Radiology, Uppsala University, Uppsala, Sweden.
| | | | | | - Kai M Eggers
- Department of Cardiology, Uppsala University Hospital, Uppsala, Sweden
- Department of Medical Sciences, Uppsala University, Uppsala, Sweden
| | | | - Håkan Ahlström
- Medical Imaging Centre, Uppsala University Hospital, 75185, Uppsala, Sweden
- Department of Surgical Sciences/Radiology, Uppsala University, Uppsala, Sweden
- Antaros Medical, BioVenture Hub, Mölndal, Sweden
| | - Mark Lubberink
- Medical Physics, Uppsala University Hospital, Uppsala, Sweden
- Department of Surgical Sciences/Radiology, Uppsala University, Uppsala, Sweden
| |
Collapse
|
4
|
Poli FE, Gulsin GS, March DS, Abdelaty AM, Parke KS, Wormleighton JV, McCann GP, Burton JO, Graham-Brown MP. The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis. J Cardiovasc Magn Reson 2020; 22:43. [PMID: 32507107 PMCID: PMC7278072 DOI: 10.1186/s12968-020-00634-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Accepted: 05/08/2020] [Indexed: 01/10/2023] Open
Abstract
BACKGROUND Identifying coronary artery disease (CAD) in patients with end-stage renal disease (ESRD) is challenging. Adenosine stress native T1 mapping with cardiovascular magnetic resonance (CMR) may accurately detect obstructive CAD and microvascular dysfunction in the general population. This study assessed the feasibility and reliability of adenosine stress native T1 mapping in patients on haemodialysis. METHODS The feasibility of undertaking rest and adenosine stress native T1 mapping using the single-shot Modified Look-Locker inversion recovery (MOLLI) sequence was assessed in 58 patients on maintenance haemodialysis using 3 T CMR. Ten patients underwent repeat stress CMR within 2 weeks for assessment of test-retest reliability of native T1, stress T1 and delta T1 (ΔT1). Interrater and intrarater agreement were assessed in 10 patients. Exploratory analyses were undertaken to assess associations between clinical variables and native T1 values in 51 patients on haemodialysis. RESULTS Mean age of participants was 55 ± 15 years, 46 (79%) were male, and median dialysis vintage was 21 (8; 48) months. All patients completed the scan without complications. Mean native T1 rest, stress and ΔT1 were 1261 ± 57 ms, 1297 ± 50 ms and 2.9 ± 2.5%, respectively. Interrater and intrarater agreement of rest T1, stress T1 and ΔT1 were excellent, with intraclass correlation coefficients (ICC) > 0.9 for all. Test-retest reliability of rest and stress native T1 were excellent or good (CoV 1.2 and 1.5%; ICC, 0.79 and 0.69, respectively). Test-retest reliability of ΔT1 was moderate to poor (CoV 27.4%, ICC 0.55). On multivariate analysis, CAD, diabetes mellitus and resting native T1 time were independent determinants of ΔT1 (β = - 0.275, p = 0.019; β = - 0.297, p = 0.013; β = - 0.455; p < 0.001, respectively). CONCLUSIONS Rest and adenosine stress native T1 mapping is feasible and well-tolerated amongst patients with ESRD on haemodialysis. Although rater agreement of the technique is excellent, test-retest reliability of ΔT1 is moderate to poor. Prospective studies should evaluate the relationship between this technique and established methods of CAD assessment and association with outcomes.
Collapse
Affiliation(s)
- Federica E Poli
- Department of Cardiovascular Sciences, University of Leicester and the NIHR Leicester Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, LE1 9HN, UK
| | - Gaurav S Gulsin
- Department of Cardiovascular Sciences, University of Leicester and the NIHR Leicester Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, LE1 9HN, UK
- NIHR Leicester Biomedical Research Centre, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Daniel S March
- Department of Cardiovascular Sciences, University of Leicester and the NIHR Leicester Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, LE1 9HN, UK
- John Walls Renal Unit, University Hospitals Leicester NHS Trust, Leicester, UK
| | - Ahmed Msek Abdelaty
- Department of Cardiovascular Sciences, University of Leicester and the NIHR Leicester Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, LE1 9HN, UK
| | - Kelly S Parke
- NIHR Leicester Biomedical Research Centre, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Joanne V Wormleighton
- NIHR Leicester Biomedical Research Centre, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Gerry P McCann
- Department of Cardiovascular Sciences, University of Leicester and the NIHR Leicester Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, LE1 9HN, UK
- NIHR Leicester Biomedical Research Centre, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - James O Burton
- Department of Cardiovascular Sciences, University of Leicester and the NIHR Leicester Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, LE1 9HN, UK
- John Walls Renal Unit, University Hospitals Leicester NHS Trust, Leicester, UK
- National Centre for Sport and Exercise Medicine, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Matthew Pm Graham-Brown
- Department of Cardiovascular Sciences, University of Leicester and the NIHR Leicester Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, LE1 9HN, UK.
- NIHR Leicester Biomedical Research Centre, University Hospitals of Leicester NHS Trust, Leicester, UK.
- John Walls Renal Unit, University Hospitals Leicester NHS Trust, Leicester, UK.
| |
Collapse
|
5
|
Tian Y, Mendes J, Wilson B, Ross A, Ranjan R, DiBella E, Adluru G. Whole-heart, ungated, free-breathing, cardiac-phase-resolved myocardial perfusion MRI by using Continuous Radial Interleaved simultaneous Multi-slice acquisitions at sPoiled steady-state (CRIMP). Magn Reson Med 2020; 84:3071-3087. [PMID: 32492235 DOI: 10.1002/mrm.28337] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 04/28/2020] [Accepted: 05/01/2020] [Indexed: 11/09/2022]
Abstract
PURPOSE To develop a whole-heart, free-breathing, non-electrocardiograph (ECG)-gated, cardiac-phase-resolved myocardial perfusion MRI framework (CRIMP; Continuous Radial Interleaved simultaneous Multi-slice acquisitions at sPoiled steady-state) and test its quantification feasibility. METHODS CRIMP used interleaved radial simultaneous multi-slice (SMS) slice groups to cover the whole heart in 9 or 12 short-axis slices. The sequence continuously acquired data without magnetization preparation, ECG gating or breath-holding, and captured multiple cardiac phases. Images were reconstructed by a motion-compensated patch-based locally low-rank reconstruction. Bloch simulations were performed to study the signal-to-noise ratio/contrast-to-noise ratio (SNR/CNR) for CRIMP and to study the steady-state signal under motion. Seven patients were scanned with CRIMP at stress and rest to develop the sequence. One human and two dogs were scanned at rest with a dual-bolus method to test the quantification feasibility of CRIMP. The dual-bolus scans were performed using both CRIMP and an ungated radial SMS saturation recovery (SMS-SR) sequence with injection dose = 0.075 mmol/kg to compare the sequences in terms of SNR, cardiac phase resolution and quantitative myocardial blood flow (MBF). RESULTS Perfusion images with multiple cardiac phases in all image slices with a temporal resolution of 72 ms/frame were obtained. Simulations and in-vivo acquisitions showed CRIMP kept the inner slices in steady-state regardless of motion. CRIMP outperformed SMS-SR in slice coverage (9 over 6), SNR (mean 20% improvement), and provided cardiac phase resolution. CRIMP and SMS-SR sequences provided comparable MBF values (rest systolic CRIMP = 0.58 ± 0.07, SMS-SR = 0.61 ± 0.16). CONCLUSION CRIMP allows for whole-heart, cardiac-phase-resolved myocardial perfusion images without ECG-gating or breath-holding. The sequence can provide MBF if an accurate arterial input function is obtained separately.
Collapse
Affiliation(s)
- Ye Tian
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.,Department of Physics and Astronomy, University of Utah, Salt Lake City, Utah, USA
| | - Jason Mendes
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
| | - Brent Wilson
- Division of Cardiovascular Medicine, University of Utah, Salt Lake City, Utah, USA
| | - Alexander Ross
- Division of Cardiovascular Medicine, University of Utah, Salt Lake City, Utah, USA
| | - Ravi Ranjan
- Division of Cardiovascular Medicine, University of Utah, Salt Lake City, Utah, USA
| | - Edward DiBella
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.,Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA
| | - Ganesh Adluru
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.,Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
6
|
Martens J, Panzer S, den Wijngaard J, Siebes M, Schreiber LM. Influence of contrast agent dispersion on bolus‐based MRI myocardial perfusion measurements: A computational fluid dynamics study. Magn Reson Med 2019; 84:467-483. [DOI: 10.1002/mrm.28125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2019] [Revised: 11/19/2019] [Accepted: 11/20/2019] [Indexed: 12/22/2022]
Affiliation(s)
- Johannes Martens
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure CenterUniversity Hospitals Würzburg Germany
- Department of Cardiovascular Imaging Comprehensive Heart Failure Center University Hospitals Würzburg Germany
| | - Sabine Panzer
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure CenterUniversity Hospitals Würzburg Germany
- Department of Cardiovascular Imaging Comprehensive Heart Failure Center University Hospitals Würzburg Germany
| | - Jeroen den Wijngaard
- Department of Biomedical Engineering & Physics Amsterdam University Medical Center University of Amsterdam Amsterdam Cardiovascular Sciences Amsterdam Netherlands
- Department of Clinical Chemistry and Hematology Diakonessenhuis Utrecht Netherlands
| | - Maria Siebes
- Department of Biomedical Engineering & Physics Amsterdam University Medical Center University of Amsterdam Amsterdam Cardiovascular Sciences Amsterdam Netherlands
| | - Laura M. Schreiber
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure CenterUniversity Hospitals Würzburg Germany
- Department of Cardiovascular Imaging Comprehensive Heart Failure Center University Hospitals Würzburg Germany
| |
Collapse
|
7
|
Tian Y, Mendes J, Pedgaonkar A, Ibrahim M, Jensen L, Schroeder JD, Wilson B, DiBella EVR, Adluru G. Feasibility of multiple-view myocardial perfusion MRI using radial simultaneous multi-slice acquisitions. PLoS One 2019; 14:e0211738. [PMID: 30742641 PMCID: PMC6370206 DOI: 10.1371/journal.pone.0211738] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Accepted: 01/18/2019] [Indexed: 11/18/2022] Open
Abstract
Purpose Dynamic contrast enhanced MRI of the heart typically acquires 2–4 short-axis (SA) slices to detect and characterize coronary artery disease. This acquisition scheme is limited by incomplete coverage of the left ventricle. We studied the feasibility of using radial simultaneous multi-slice (SMS) technique to achieve SA, 2-chamber and/or 4-chamber long-axis (2CH LA and/or 4CH LA) coverage with and without electrocardiography (ECG) gating using a motion-robust reconstruction framework. Methods 12 subjects were scanned at rest and/or stress, free breathing, with or without ECG gating. Multiple sets of radial SMS k-space were acquired within each cardiac cycle, and each SMS set sampled 3 parallel slices that were either SA, 2CH LA, or 4CH LA slices. The radial data was interpolated onto Cartesian space using an SMS GRAPPA operator gridding method. Self-gating and respiratory states binning of the data were done. The binning information as well as a pixel tracking spatiotemporal constrained reconstruction method were applied to obtain motion-robust image reconstructions. Reconstructions with and without the pixel tracking method were compared for signal-to-noise ratio and contrast-to-noise ratio. Results Full coverage of the heart (at least 3 SA and 3 LA slices) during the first pass of contrast at every heartbeat was achieved by using the radial SMS acquisition. The proposed pixel tracking reconstruction improves the average SNR and CNR by 21% and 30% respectively, and reduces temporal blurring for both gated and ungated acquisitions. Conclusion Acquiring simultaneous multi-slice SA, 2CH LA and/or 4CH LA myocardial perfusion images in every heartbeat is feasible in both gated and ungated acquisitions. This can add confidence when detecting and characterizing coronary artery disease by revealing ischemia in different views, and by providing apical coverage that is improved relative to SA slices alone. The proposed pixel tracking framework improves the reconstruction while adding little computational cost.
Collapse
Affiliation(s)
- Ye Tian
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
- Department of Physics and Astronomy, University of Utah, Salt Lake City, Utah, United States of America
| | - Jason Mendes
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
| | - Apoorva Pedgaonkar
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
| | - Mark Ibrahim
- Division of Cardiology, University of Utah, Salt Lake City, Utah, United States of America
| | - Leif Jensen
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
| | - Joyce D. Schroeder
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
| | - Brent Wilson
- Division of Cardiology, University of Utah, Salt Lake City, Utah, United States of America
| | - Edward V. R. DiBella
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
| | - Ganesh Adluru
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
- * E-mail:
| |
Collapse
|
8
|
Brown LAE, Onciul SC, Broadbent DA, Johnson K, Fent GJ, Foley JRJ, Garg P, Chew PG, Knott K, Dall’Armellina E, Swoboda PP, Xue H, Greenwood JP, Moon JC, Kellman P, Plein S. Fully automated, inline quantification of myocardial blood flow with cardiovascular magnetic resonance: repeatability of measurements in healthy subjects. J Cardiovasc Magn Reson 2018; 20:48. [PMID: 29983119 PMCID: PMC6036695 DOI: 10.1186/s12968-018-0462-y] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Accepted: 05/23/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Non-invasive assessment of myocardial ischaemia is a cornerstone of the diagnosis of coronary artery disease. Measurement of myocardial blood flow (MBF) using positron emission tomography (PET) is the current reference standard for non-invasive quantification of myocardial ischaemia. Dynamic myocardial perfusion cardiovascular magnetic resonance (CMR) offers an alternative to PET and a recently developed method with automated inline perfusion mapping has shown good correlation of MBF values between CMR and PET. This study assessed the repeatability of myocardial perfusion mapping by CMR in healthy subjects. METHODS Forty-two healthy subjects were recruited and underwent adenosine stress and rest perfusion CMR on two visits. Scans were repeated with a minimum interval of 7 days. Intrastudy rest and stress MBF repeatability were assessed with a 15-min interval between acquisitions. Interstudy rest and stress MBF and myocardial perfusion reserve (MPR) were measured for global myocardium and regionally for coronary territories and slices. RESULTS There was no significant difference in intrastudy repeated global rest MBF (0.65 ± 0.13 ml/g/min vs 0.62 ± 0.12 ml/g/min, p = 0.24, repeatability coefficient (RC) =24%) or stress (2.89 ± 0.56 ml/g/min vs 2.83 ± 0.64 ml/g/min, p = 0.41, RC = 29%) MBF. No significant difference was seen in interstudy repeatability for global rest MBF (0.64 ± 0.13 ml/g/min vs 0.64 ± 0.15 ml/g/min, p = 0.80, RC = 32%), stress MBF (2.71 ± 0.61 ml/g/min vs 2.55 ± 0.57 ml/g/min, p = 0.12, RC = 33%) or MPR (4.24 ± 0.69 vs 3.73 ± 0.76, p = 0.25, RC = 36%). Regional repeatability was good for stress (RC = 30-37%) and rest MBF (RC = 32-36%) but poorer for MPR (RC = 35-43%). Within subject coefficient of variation was 8% for rest and 11% for stress within the same study, and 11% for rest and 12% for stress between studies. CONCLUSIONS Fully automated, inline, myocardial perfusion mapping by CMR shows good repeatability that is similar to the published PET literature. Both rest and stress MBF show better repeatability than MPR, particularly in regional analysis.
Collapse
Affiliation(s)
- Louise A. E. Brown
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - Sebastian C. Onciul
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - David A. Broadbent
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
- Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, Leeds, LS1 3EX UK
| | - Kerryanne Johnson
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - Graham J. Fent
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - James R. J. Foley
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - Pankaj Garg
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - Pei G. Chew
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - Kristopher Knott
- Barts Heart Centre, The Cardiovascular Magnetic Resonance Imaging Unit and The Inherited Cardiovascular Diseases Unit, St Bartholomew’s Hospital, West Smithfield, London, UK
| | - Erica Dall’Armellina
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - Peter P. Swoboda
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - Hui Xue
- National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, Bethesda, MD USA
| | - John P. Greenwood
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| | - James C. Moon
- Barts Heart Centre, The Cardiovascular Magnetic Resonance Imaging Unit and The Inherited Cardiovascular Diseases Unit, St Bartholomew’s Hospital, West Smithfield, London, UK
| | - Peter Kellman
- National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, Bethesda, MD USA
| | - Sven Plein
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Clarendon Way, Leeds, LS2 9JT UK
| |
Collapse
|
9
|
Abstract
Quantitative cardiovascular magnetic resonance (CMR) imaging can be used to characterize fibrosis, oedema, ischaemia, inflammation and other disease conditions. However, the need to reduce artefacts arising from body motion through a combination of electrocardiography (ECG) control, respiration control, and contrast-weighting selection makes CMR exams lengthy. Here, we show that physiological motions and other dynamic processes can be conceptualized as multiple time dimensions that can be resolved via low-rank tensor imaging, allowing for motion-resolved quantitative imaging with up to four time dimensions. This continuous-acquisition approach, which we name cardiovascular MR multitasking, captures — rather than avoids — motion, relaxation and other dynamics to efficiently perform quantitative CMR without the use of ECG triggering or breath holds. We demonstrate that CMR multitasking allows for T1 mapping, T1-T2 mapping and time-resolved T1 mapping of myocardial perfusion without ECG information and/or in free-breathing conditions. CMR multitasking may provide a foundation for the development of setup-free CMR imaging for the quantitative evaluation of cardiovascular health.
Collapse
|
10
|
Likhite D, Suksaranjit P, Adluru G, Wilson B, DiBella E. Estimating extraction fraction and blood flow by combining first-pass myocardial perfusion and T1 mapping results. Quant Imaging Med Surg 2017; 7:480-495. [PMID: 29184761 DOI: 10.21037/qims.2017.08.07] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Background Quantifying myocardial perfusion is complicated by the complexity of pharmacokinetic model being used and the reliability of perfusion parameter estimates. More complex modeling provides more information about the underlying physiology, but too many parameters in complex models introduce a new problem of reliable estimation. To overcome the problem of multiple parameters, we have developed a technique that combines knowledge from two different cardiac magnetic resonance (MR) imaging techniques: dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and T1 mapping. Using extracellular volume (ECV) estimates from T1 mapping may allow more robust model parameter estimates. Methods Simulations and human scans were performed. The myocardial perfusion scans used an ungated saturation recovery prepared TurboFLASH pulse sequence. Four short-axis (SA) slices were acquired after a single saturation pulse with a saturation recovery time of ~25 ms before the first slice. Gadoteridol was injected and ~240 frames were acquired over a minute with shallow breathing and no electrocardiograph (ECG) gating. This was followed 20±5 minutes later by an injection of regadenoson to induce hyperemia. The data were acquired using an under-sampled golden angle radial acquisition. Modified look-locker inversion recovery (MOLLI) T1 mapping was performed in 3 slices pre- and post-contrast. The pre- and post-contrast T1 maps were used for ECV estimation. Quantification of perfusion was done using a 4-parameter model with additional information about ECV supplied during model fitting. Phase contrast scans of the coronary sinus (CS) were acquired at rest and immediately after the stress perfusion acquisition to estimate global flow. Results Without ECV information, the 5-parameter model fails to converge to a unique solution and often gives incorrect estimates for the perfusion parameters. The myocardial blood flow (MBF) estimates during rest and stress were 0.9±0.1 and 2.3±0.6 mL/min/g, respectively. The extraction fraction estimates were 0.49±0.04 and 0.34±0.05 during rest and stress, respectively. Conclusions These results show that it is possible to successfully fit a dynamic perfusion model with an extraction fraction parameter by using information from T1 mapping scans. This hybrid approach is especially important when the 5-parameter model alone fails to converge on a unique solution. This work is a good example of exploiting information overlaps between various cardiac MR imaging techniques.
Collapse
Affiliation(s)
- Devavrat Likhite
- Department of Radiology and Imaging Sciences, Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, UT, USA
| | | | - Ganesh Adluru
- Department of Radiology and Imaging Sciences, Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, UT, USA
| | - Brent Wilson
- Division of Cardiology, University of Utah, Salt Lake City, UT, USA
| | - Edward DiBella
- Department of Radiology and Imaging Sciences, Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, UT, USA.,Department of Bioengineering, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|