1
|
Chevalier B, Bedretdinova D, Pellot-Barakat C, Maître X, Creze M. Evaluation of the Reproducibility of MR Elastography Measurements of the Lumbar Back Muscles. J Magn Reson Imaging 2024; 60:1037-1048. [PMID: 38100302 DOI: 10.1002/jmri.29178] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 11/21/2023] [Accepted: 11/22/2023] [Indexed: 12/17/2023] Open
Abstract
BACKGROUND MR elastography (MRE) may provide quantitative imaging biomarkers of lumbar back muscles (LBMs), complementing MRI in spinal diseases by assessing muscle mechanical properties. However, reproducibility analyses for MRE of LBM are lacking. PURPOSE To assess technical failure, within-day and inter-day reproducibility, robustness with the excitation source positioning, and inter-observer agreement of MRE of muscles. STUDY TYPE Prospective. SUBJECTS Seventeen healthy subjects (mean age 28 ± 4 years; 11 females). FIELD STRENGTH/SEQUENCE 1.5 T, gradient-echo MRE, T1-weighted turbo spin echo. ASSESSMENT The pneumatic driver was centered at L3 level. Four MRE were performed during two visits, 2-4 weeks apart, each consisting of two MRE with less than 10 minutes inter-scan interval. At Visit 1, after the first MRE, the coil and driver were removed, then reinstalled. The MRE was repeated. At Visit 2, following the first MRE, only the driver was moved down 5 cm. The MRE was repeated. Two radiologists segmented the multifidus and erector spinae muscles. STATISTICAL TESTS Paired t-test, analysis of variance, intraclass correlation coefficients (ICCs). P-values <0.05 were considered statistically significant. RESULTS Mean stiffness of LBM ranged from 1.44 to 1.60 kPa. Mean technical failure rate was 2.5%. Inter-observer agreement was excellent (ICC ranging from 0.82 [0.64-0.96] to 0.99 [0.98-0.99] in the multifidus, and from 0.85 [0.69-0.92] to 0.99 [0.97-0.99] in the erector spinae muscles). Within-day reproducibility was fair in the multifidus (ICC: 0.53 [0.47-0.77]) and good in the erector spinae muscles (ICC: 0.74 [0.48-0.88]). Reproducibility after moving the driver was excellent in both multifidus (ICC: 0.85 [0.69-0.93]) and erector spinae muscles (ICC: 0.84 [0.67-0.92]). Inter-day reproducibility was excellent in the multifidus (ICC: 0.76 [0.48-0.89]) and poor in the erector spinae muscles (ICC: 0.23 [-0.61 to 0.63]). DATA CONCLUSION MRE of LBM provides measurements of stiffness with fair to excellent reproducibility and excellent inter-observer agreement. However, inter-day reproducibility in the multifidus muscles indicated that the herein used MRE protocol may not be optimal for this muscle. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Benjamin Chevalier
- Department of Radiology, Cochin Hospital, Université Paris Cité, APHP, Paris, France
| | - Dina Bedretdinova
- Center for Research in Epidemiology and StatisticS (CRESS), Université Paris Cité and Université Sorbonne Paris Nord, Inserm, INRAE, Paris, France
| | - Claire Pellot-Barakat
- Laboratoire d'Imagerie Biomédicale Multimodale, BIOMAPS, Université Paris-Saclay, Service Hospitalier Frederic Joliot, Orsay, France
| | - Xavier Maître
- Laboratoire d'Imagerie Biomédicale Multimodale, BIOMAPS, Université Paris-Saclay, Service Hospitalier Frederic Joliot, Orsay, France
| | - Maud Creze
- Laboratoire d'Imagerie Biomédicale Multimodale, BIOMAPS, Université Paris-Saclay, Service Hospitalier Frederic Joliot, Orsay, France
- Department of Radiology, Bicêtre Hospital, Université Paris-Saclay, APHP, Le Kremlin Bicêtre, France
- Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, Paris, France
| |
Collapse
|
2
|
Wator J, Battis A, Vellucci C, Beaudette SM. The acute effects of kinesio-taping on movement kinematics and muscle co-activation in rowing athletes. J Back Musculoskelet Rehabil 2024; 37:751-760. [PMID: 38250754 DOI: 10.3233/bmr-230216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/23/2024]
Abstract
BACKGROUND Rowing-related low back disorders may occur from inconsistent technique, high trunk flexion and training volumes, overactivation of paraspinal muscles, and fatigue. OBJECTIVE To examine if kinesiology tape (KT) affixed to the trunk dorsum affects muscular co-activation and neuromuscular control to limit dangerous rowing movements and associated injuries. METHODS Participants (n= 18) completed two 2000 m rowing trials under BASELINE and KT conditions. KT was applied to the skin superficial to the paraspinals bilaterally with 60% pre-strain. Participants were instructed to minimize any sensation of tension. Whole body kinematics were obtained using inertial measurement units (IMUs), and surface electromyograms (EMGs) were recorded from trunk and lower extremity. Changes in joint range-of-motion (ROM) and co-activation indices (CAIs) were analyzed for shoulder, lumbar, hip, and knee. RESULTS Responding participants (n= 5) were identified by reduced maximum lumbar flexion during the KT condition. As expected, significant differences occurred in maximum and minimum lumbar flexion/extension between responders and non-responders to KT. Additionally, there was significant reduction in mean trunk muscle co-activation in both those who did and did not respond to KT through reductions in maximum lumbar flexion. CONCLUSION KT can be an effective at reducing mean trunk co-activation during a rowing trial in the flexed catch position. Variable responses suggest that further work is necessary to optimize the efficacy of sensory cues derived from KT during rowing movements.
Collapse
|
3
|
van Amstel R, Noten K, Malone S, Vaes P. Fascia Tissue Manipulations in Chronic Low Back Pain: A Pragmatic Comparative Randomized Clinical Trial of the 4xT Method ® and Exercise Therapy. Life (Basel) 2023; 14:7. [PMID: 38276256 PMCID: PMC10820544 DOI: 10.3390/life14010007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/14/2023] [Accepted: 12/18/2023] [Indexed: 01/27/2024] Open
Abstract
BACKGROUND The 4xT method is a protocolized practice in treating musculoskeletal disorders. The 4xT method consists of four components: Test (functional diagnostic test), Trigger (fascia tissue manipulations), Tape (elastic taping), and Train (exercise). There is a lack of clinical studies evaluating the treatment effects of the use of the 4xT method. METHODS A randomized controlled trial was conducted to compare the effectiveness of the 4xT method and exercise therapy-only in patients with chronic nonspecific low back pain. Based on a priori sample size calculation, fifty-one individuals with chronic nonspecific low back pain were randomly assigned to either the 4xT or exercise group. Both groups underwent a six-week rehabilitation program with two treatments per week. The primary outcomes were trunk flexion and extension mobility, trunk flexion, and extension mobility-dependent pain, and quality of life evaluated during a 6-week therapy period and after a 6-week therapy-off period. RESULTS Interaction effects were noted in all outcomes. The 4xT group showed significant improvements over time for trunk flexion and extension mobility, trunk flexion and extension mobility-dependent pain, and quality of life (p < 0.05), with no significant relapse post-therapy (except for extension mobility). The exercise group exhibited significant within-time changes in the quality of life, as measured with the VAS (p < 0.05), but not for EQ-5D-3L. CONCLUSIONS The results of this study demonstrate that the 4xT method stands out as a promising and impactful treatment option for chronic nonspecific low back pain individuals, as it demonstrated significant reductions in mobility-dependent pain, increased trunk mobility, and improved quality of life compared to exercise-only treatments.
Collapse
Affiliation(s)
- Robbert van Amstel
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Amsterdam Movement Sciences, Vrije Universiteit Amsterdam, 1081 Amsterdam, The Netherlands
- Fysio Science Department, Fysio Physics Groups, 3401 IJsselstein, The Netherlands
| | - Karl Noten
- Fysio Science Department, Fysio Physics Groups, 3401 IJsselstein, The Netherlands
| | - Shaun Malone
- Department of Rehabilitation Sciences and Physiotherapy (MOVANT), University of Antwerp, Wilrijk, 2000 Antwerpen, Belgium
| | - Peter Vaes
- Faculty of Rehabilitation Science and Physical Therapy, Vrije Universiteit Brussel, 1050 Brussels, Belgium;
| |
Collapse
|
4
|
Wang X, Shao X, Yu R, Wang Y, Deng F, Adams R, Han J. Acute effects of kinesiology tape on dynamic balance control in chronic ankle instability: An exploratory study. Phys Ther Sport 2023; 62:65-70. [PMID: 37399706 DOI: 10.1016/j.ptsp.2023.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 06/26/2023] [Accepted: 06/27/2023] [Indexed: 07/05/2023]
Abstract
OBJECTIVE To investigate the acute effect of the four-strip kinesiology taping (KT) technique on dynamic balance control in the Y Balance Test (YBT), and to explore the relationship between the YBT and Cumberland Ankle Instability Tool (CAIT) scores in individuals with and without chronic ankle instability (CAI). METHODS 16 CAI and 16 non-CAI participants were involved. Two groups completed the YBT in the no-tape barefoot and the KT condition at random. The CAIT was completed on the first day. Bonferroni test was used to analyze YBT scores in three directions for post hoc analysis. Spearman's correlation was used to analyze the relationship between YBT scores in the no-tape barefoot condition and CAIT scores. RESULTS This KT application significantly improved YBT performance. The YBT scores in the anterior direction (YBT-A), posteromedial direction (YBT-PM), and posterolateral direction (YBT-PL) for the CAI group were significantly improved after taping. However, in the non-CAI group, only YBT-PM score was significantly improved after taping. Three YBT scores were all moderately correlated with the CAIT score. CONCLUSION This KT technique can immediately improve dynamic balance in CAI patients. Dynamic balance performance was moderately related to the degree of self-perceived instability in individuals with and without CAI.
Collapse
Affiliation(s)
- Xiaotian Wang
- Department of Orthopedics and Traumatology, Jinhua Hospital of Traditional Chinese Medicine, Jinhua, Zhejiang, China
| | - Xuerong Shao
- School of Exercise and Health, Shanghai University of Sport, Shanghai, China
| | - Ruoni Yu
- School of Medicine, Jinhua Polytechnic, Jinhua, Zhejiang, China
| | - Yudi Wang
- School of Physical Education and Nursing, Chengdu College of Arts and Sciences, Chengdu, Sichuan, China
| | - Fawei Deng
- Department of Rehabilitation, Second Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China
| | - Roger Adams
- Research Institute for Sports and Exercise, University of Canberra, Canberra, ACT, Australia
| | - Jia Han
- College of Rehabilitation Sciences, Shanghai University of Medicine & Health Sciences, Shanghai, China; Faculty of Health, Arts and Design, Swinburne University of Technology, Hawthorn, ACT, Australia.
| |
Collapse
|
5
|
Vo MHT, Lin CJ, Chieh HF, Kuo LC, An KN, Wang YL, Su FC. Behavior of medial gastrocnemius muscle beneath kinesio taping during isometric contraction and badminton lunge performance after fatigue induction. Sci Rep 2023; 13:1779. [PMID: 36720990 PMCID: PMC9889375 DOI: 10.1038/s41598-023-28818-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Accepted: 01/25/2023] [Indexed: 02/02/2023] Open
Abstract
Kinesio taping (KT) is widely used in sports for performance improvement and injury prevention. However, little is known of the behavior of the muscle region beneath the KT with movement, particularly when the muscle is fatigued. Accordingly, this study investigated the changes in the medial gastrocnemius muscle architecture and fascia thickness when using KT during maximum isometric plantar flexion (MVIC) and badminton lunges following heel rise exercises performed to exhaustion. Eleven healthy collegiate badminton players (4 males and 7 females) were recruited. All of the participants performed two tasks (MVIC and badminton lunge) with a randomized sequence of no taping, KT and sham taping and repeated following exhaustive repetitive heel rise exercise. In the MVIC task, the fascia thickness with the medial gastrocnemius muscle at rest significantly decreased following fatigue induction both without taping and with KT and sham taping (p = 0.036, p = 0.028 and p = 0.025, respectively). In the lunge task, the fascia thickness reduced after fatigue induction in the no taping and sham taping trials; however, no significant change in the fascia thickness occurred in the KT trials. Overall, the results indicate that KT provides a better effect during dynamic movement than in isometric contraction.
Collapse
Affiliation(s)
- Minh Hoang-Thuc Vo
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chien-Ju Lin
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Hsiao-Feng Chieh
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Li-Chieh Kuo
- Department of Occupational Therapy, National Cheng Kung University, Tainan, Taiwan
| | - Kai-Nan An
- Division of Orthopedic Research, Mayo Clinic, Rochester, USA
| | - Yu-Lin Wang
- Department of Rehabilitation, Chi Mei Medical Center, Tainan, Taiwan
| | - Fong-Chin Su
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
| |
Collapse
|
6
|
van Amstel RN, Jaspers RT, Pool-Goudzwaard AL. Skin Displacement as fascia tissue manipulation at the lower back affects instantaneously the flexion-and extension spine, pelvis, and hip range of motion. Front Physiol 2022; 13:1067816. [PMID: 36505071 PMCID: PMC9727291 DOI: 10.3389/fphys.2022.1067816] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 10/31/2022] [Indexed: 11/24/2022] Open
Abstract
Low back pain (LBP), associated with spine, pelvis, and hip mobility impairments can be caused by tight muscle contractions, to protect sensitized lumbar fasciae. Fascia tissue manipulations are used to treat lumbar fascia in LBP. The effect of fascia tissue manipulations through lumbodorsal skin displacement (SKD) on mobility is inconclusive likely depending on the location and displacement direction of the manipulation. This study aimed to assess whether lumbodorsal SKD affects the flexion -and extension range of motion (ROM), in healthy subjects. Furthermore, we aimed to test the effect of SKD at different locations and directions. Finally, to assess intertester and intratester reliability of SKD. Effects of SKD were tested in a motion capture, single-blinded, longitudinal, experimental study. Sixty-three subjects were randomly assigned to SKD- or sham group. SKD group was subjected to either mediolateral directed SKD during flexion or extension movement, versus a sham. The thoracic, lumbar, and hip angles and finger floor distance were measured to assess the change in ROM. Statistics indicated that the effect size in instantaneously change of flexion -and extension ROM by SKD was large (Effect size: flexion η2 p = 0.12-0.90; extension η2 p = 0.29-0.42). No significant effect was present in the sham condition. Flexion ROM decreased whereas the extension ROM increased, depending on SKD location- and displacement direction (p < 0.05). The ICC indicates a good intertester and intratester reliability (resp. ICC3,k = 0.81-0.93; ICC3,1 = 0.70-0.84). Lumbodorsal SKD affects the flexion- and extension spine, pelvis, and hip range of motion. The effects of SKD are direction- and location dependent as well as movement (flexion/extension) specific. Lumbodorsal SKD during flexion and extension may be useful to determine whether or not a patient would benefit from fascia tissue manipulations. Further research is required to obtain insight into the mechanisms via which the SKD affects ROM and muscle activation, in healthy, asymptomatic-LBP, and LBP subjects.
Collapse
Affiliation(s)
- Robbert N. van Amstel
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Amsterdam Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, Netherlands,Fysio Science Department, Fysio Physics Group, IJsselstein, Netherlands,*Correspondence: Robbert N. van Amstel, ; Annelies L. Pool-Goudzwaard,
| | - Richard T. Jaspers
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Amsterdam Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Annelies L. Pool-Goudzwaard
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Amsterdam Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, Netherlands,SOMT, University of Physiotherapy, Amersfoort, Netherlands,*Correspondence: Robbert N. van Amstel, ; Annelies L. Pool-Goudzwaard,
| |
Collapse
|
7
|
Reliability of Gradient-Echo Magnetic Resonance Elastography of Lumbar Muscles: Phantom and Clinical Studies. Diagnostics (Basel) 2022; 12:diagnostics12061385. [PMID: 35741195 PMCID: PMC9221855 DOI: 10.3390/diagnostics12061385] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 05/24/2022] [Accepted: 05/31/2022] [Indexed: 12/04/2022] Open
Abstract
Magnetic resonance elastography (MRE) has been used to successfully characterize the mechanical behavior of healthy and diseased muscles, but no study has been performed to investigate the reliability of MRE on lumbar muscles. The objective of this work was to determine the reliability of MRE techniques on lumbar muscles in both ex vivo phantom and in vivo human studies. In this study, fresh porcine leg muscles were used in the phantom study, and 80 healthy adults (38.6 ± 11.2 years, 40 women) were recruited in the human study. Five repeated stiffness maps were obtained from both the phantom and human muscles by using a gradient-echo MRE sequence with a pneumatic vibration on a 1.5 T MR scanner. The technical failure rate, coefficient of variation (CV), and quality score were assessed to evaluate the reliability of MRE, respectively. Analysis of variance was performed to compare the stiffness between different lumbar muscles, and the difference was significant if p < 0.05 after Bonferroni correction. The results showed that the MRE achieved a zero technical failure rate and a low CV of stiffness (6.24 ± 1.41%) in the phantom muscles. However, in the human study, the MRE exhibited high CVs of stiffness (21.57%−25.24%) in the lumbar muscles, and the technical failure rate was higher in psoas muscles (60.0−66.3% in) than in paraspinal muscles (0.0−2.5%). Further, higher quality scores were noticed in paraspinal muscles (7.31−7.71) than those in psoas muscles (1.83−2.06). In conclusion, the MRE was a reliable technique to investigate the mechanical property of lumbar muscles, but it was less reliable to assess stiffness in psoas muscles than paraspinal muscles.
Collapse
|
8
|
Yin L, Liu K, Liu C, Feng X, Wang L. Effect of Kinesiology Tape on Muscle Activation of Lower Extremity and Ankle Kinesthesia in Individuals With Unilateral Chronic Ankle Instability. Front Physiol 2022; 12:786584. [PMID: 34975539 PMCID: PMC8718686 DOI: 10.3389/fphys.2021.786584] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 11/24/2021] [Indexed: 12/26/2022] Open
Abstract
Background: The purpose of the study was to determine the effect of kinesiology tape (KT) on lower limb muscle activation during computerized dynamic posturography (CDP) tasks and ankle kinesthesia in individuals with chronic ankle instability (CAI). Methods: Thirty-five men with CAI participated in this study. The experimental procedure followed a repeated measures design. Muscle activation of lower extremity and ankle kinesthesia of participants were measured using four taping treatments, namely, KT, athletic tape (AT), sham tape (ST), and no tape (NT) in a randomized order. Muscle activation was assessed using surface electromyography (sEMG) synchronized with CDP tests from seven lower extremity muscles of the unstable limb. Ankle kinesthesia was measured by using a threshold to detect the passive motion direction of the unstable ankle. Parameters were analyzed by using a one-way repeated measures ANOVA and followed by pairwise comparisons with a Bonferroni correction. Results: No significant difference was observed among different taping treatments for the majority of parameters during CDP. Except for condition 4 with open eyes, sway-referenced surface, and fixed surround in the sensory organization test (SOT), gastrocnemius medialis root mean square (RMS) was 28.19% lower in AT compared with NT (p = 0.021, 95% CI = 0.002-0.039), while gastrocnemius lateralis RMS was 20.25% lower in AT compared with KT (p = 0.038, 95% CI = 0.000-0.021). In forward-small sudden translation from motor control test (MCT), for peroneal longus (PL), RMS was 24.04% lower in KT compared with ST (p = 0.036, 95% CI = 0.000-0.018). In toes-down sudden rotation from adaption test (ADT), for PL, RMS was 23.41% lower in AT compared with ST (p = 0.015, 95% CI = 0.002-0.027). In addition, no significant difference was observed for a threshold to the detection of passive motion direction among different taping treatments. Conclusion: This study indicated that KT had minimal effect on the muscle activation of the unstable lower limb during static stance, self-initiated, and externally triggered perturbation tasks from CDP and ankle kinesthesia among individuals with CAI, suggesting that the benefit of KT was too small to be clinically worthwhile during application for CAI.
Collapse
Affiliation(s)
- Lulu Yin
- Rehabilitation Center, The First Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou, China
| | - Kun Liu
- Department of Rehabilitation Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Chengmei Liu
- Rehabilitation Center, The First Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou, China
| | - Xiaodong Feng
- Rehabilitation Center, The First Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou, China.,College of Rehabilitation Medicine, Henan University of Chinese Medicine, Zhengzhou, China
| | - Lin Wang
- School of Kinesiology, Shanghai University of Sport, Shanghai, China
| |
Collapse
|
9
|
van Amstel RN, Noten K, van den Boomen LN, Brandon T, Tulner SAF, Jaspers RT, Pool-Goudzwaard AL. Systematic Review of Lumbar Elastic Tape on Trunk Mobility: A Debatable Issue. Arch Rehabil Res Clin Transl 2021; 3:100131. [PMID: 34589682 PMCID: PMC8463465 DOI: 10.1016/j.arrct.2021.100131] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Objectives To systematically review the literature to analyze the effect of lumbar elastic tape application on trunk mobility, surpassing the minimal detectable change of the used outcome measurement tool, and to analyze the additional effect of applied tension and direction of elastic tape application in low back pain and participants without low back pain. Data Sources Four databases were used: PubMed, Web of Science, Physiotherapy Evidence Database (PEDro), and Google Scholar. Study Selection The inclusion criteria were randomized and clinical controlled trials evaluating the effectiveness of lumbar elastic tape application on trunk mobility. Data Extraction Two researchers executed the search and a third author was consulted to resolve disagreements. The methodological quality was scored using the PEDro scale, with studies scoring ≤5 being excluded. Data Synthesis Eight out of 6799 studies were included; 5 studied individuals with low back pain, and 3 studied participants without low back pain. Two studies scored low on the PEDro scale and were excluded. None of the reported significant changes in trunk mobility due to elastic tape application exceeded the indicated minimal detectable change. No conclusions can be drawn from the direction and applied tension of elastic tape application. Conclusions Based on the results of this systematic review, there is no evidence supporting the effect of lumbar elastic tape application. We recommend consensus in the use of more reliable and valid instruments in future studies.
Collapse
Key Words
- Athletic tape
- CCT, controlled clinical trial
- ETA, elastic tape application
- FFD, Finger Floor Distance test
- FROM, flexion range of motion
- Hip
- LBP, low back pain
- MDC, minimal detectable change
- PEDro, Physiotherapy Evidence Database
- RCT, randomized controlled trial
- ROM, range of motion
- Range of motion, articular
- Rehabilitation
- Spine
- TRM, trunk mobility
Collapse
Affiliation(s)
- Robbert N van Amstel
- Fysio Science Department, Fysio Physics Fysiotherapie, IJsselstein.,Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam
| | - Karl Noten
- Fysio Science Department, Fysio Physics Fysiotherapie, IJsselstein
| | | | - Tom Brandon
- Department of Sports Medicine, Isala Medical Hospital, Zwolle
| | - Sven A F Tulner
- Department Orthopedic Surgery, OrthoDirect Medical Clinic, Amsterdam, The Netherlands
| | - Richard T Jaspers
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam
| | - Annelies L Pool-Goudzwaard
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam
| |
Collapse
|
10
|
Abstract
ABSTRACT Introduction Discuss the application of magnetic resonance imaging in evaluating ankle motion injury. Objective Verify the influencing factors of magnetic resource imaging (MRI) diagnosis based on the linear regression algorithm model. Methods The experimental group was diagnosed by MRI, while the control group was diagnosed by plain X-ray. After that, the mathematical model of the linear regression algorithm was constructed. Results It could be concluded that the MRI detection rate was 85.71%, and the X-ray plain film detection rate was 77.14%. The linear regression model analysis showed that the P-value of cartilage injury, tendon fracture, bone contusion, and soft tissue swelling was greater than 0.05. Conclusions MRI has more advantages in the application of ankle joint diagnosis. And ligament injury and joint effusion are the influencing factors of MRI diagnosis, which can highly indicate the authenticity of the injury in the ankle joint. Level of evidence II; Therapeutic studies - investigation of treatment results.
Collapse
Affiliation(s)
- Fan Rao
- Hunan Normal University, China
| |
Collapse
|
11
|
Yin L, Du L, Li Y, Xiao Y, Zhang S, Ma H, He W. Quantitative Evaluation of Gastrocnemius Medialis Stiffness During Passive Stretching Using Shear Wave Elastography in Patients with Parkinson's Disease: A Prospective Preliminary Study. Korean J Radiol 2021; 22:1841-1849. [PMID: 34431245 PMCID: PMC8546131 DOI: 10.3348/kjr.2020.1338] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 05/31/2021] [Accepted: 06/01/2021] [Indexed: 01/11/2023] Open
Abstract
Objective To prospectively investigate the feasibility of shear wave elastography (SWE) as a new quantitative and objective method for evaluating the stiffness of the gastrocnemius medialis (GM) muscle during passive stretching in patients with Parkinson's disease (PD). Materials and Methods SWE of the GM muscle was performed in 28 patients with PD [13 female and 15 male; mean age ± standard deviation (SD): 63.0 ± 8.5 years] and 12 healthy controls (5 female and 7 male; mean age ± SD: 59.3 ± 6.4 years) during passive ankle rotation. A Young's modulus-ankle angle curve was constructed. The GM slack angle and baseline Young's modulus (E0) were compared between the markedly symptomatic and mildly symptomatic sides of patients with PD, and healthy controls. Additionally, the correlation between the GM slack angle and the severity of rigidity, and the observer reproducibility of SWE in determining the GM slack angle were evaluated. Results The GM slack angle was smaller on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of −29.13° ± 3.79° and −25.65° ± 3.39°, respectively, vs. −21.22° ± 3.52°; p < 0.001 and p = 0.006, respectively). Additionally, in patients with PD, the GM slack angle on the markedly symptomatic side was smaller than that on the mildly symptomatic side (p = 0.003). The E0 value was lower on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of 10.11 ± 2.85 kPa and 10.08 ± 1.88 kPa, respectively, vs. 12.23 ± 1.02 kPa; p = 0.012 and p < 0.001, respectively). However, no significant difference was found between the markedly and mildly symptomatic sides in patients with PD (p = 0.634). A negative linear relationship was observed between the GM slack angle and lower limb rigidity score on the markedly symptomatic side in patients with PD (r = −0.719; p < 0.001). The intraclass correlation coefficients for observer reproducibility of SWE ranged from 0.880 to 0.951. Conclusion The slack angle determined by SWE may be a useful quantitative and reproducible method for evaluating muscle stiffness in patients with PD.
Collapse
Affiliation(s)
- Lu Yin
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Lijuan Du
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Yuanzi Li
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Yang Xiao
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Shiquan Zhang
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Huizi Ma
- Center for Movement Disorders, Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Wen He
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
| |
Collapse
|
12
|
Zúñiga LDO, López CAG, González ER. Ultrasound Elastography in the Assessment of the Stiffness of Spastic Muscles: A Systematic Review. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1448-1464. [PMID: 33707090 DOI: 10.1016/j.ultrasmedbio.2021.01.031] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 01/22/2021] [Accepted: 01/29/2021] [Indexed: 06/12/2023]
Abstract
The incidence of muscle spasticity is high in patients with diseases of the central nervous system. This condition leads to significant limitations in movement and impaired functional capacities. Muscle spasticity manifests as changes in the mechanical properties of the muscles. This muscle disorder is generally assessed using qualitative methods, whose validity, reliability and sensitivity are questionable. In recent years, ultrasound elastography (USE) has been used as a non-invasive technique for characterizing the stress response and mechanical properties of individual muscles in the evaluation of spasticity. This article presents a systematic review of the USE techniques, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) declaration guidelines, used for the evaluation of muscle stiffness caused by spasticity. The articles selected in this study were evaluated using the Quality Appraisal of Diagnostic Reliability (QAREL) tool. Mainly, studies on the assessment of spasticity involving the evaluation of muscle stiffness with USE techniques (i.e., shear-wave elastography [SWE] or compression elastography [CE]) were selected. Then, common topics related to the assessment of spastic muscles and the statistical results of these studies were classified. Of 21 articles, nine used only CE, 10 used only SWE and two used both techniques. In the studies, statistically significant differences were observed in the measurements of muscle stiffness between the paretic and non-paretic sides as well as between patients and healthy patients. The clinical measurements obtained, devices used and assessment and probe positions for both techniques were discussed. The most frequently studied muscles were the biceps (n = 7) and gastrocnemius (n = 11). On applying the QAREL tool, we found that only two studies showed compliance at 80%-90%, seven studies at 50%-70% and the remaining 12 at 10%-40%. The results showed that USE techniques have limitations in spasticity assessment, such as subjectivity because of the lack of standardized protocols. A deficit of studies on intra-operator and inter-operator measurements indicates that this technique is not yet mature for spasticity diagnosis, although it is a promising diagnostic tool for designing treatment plans and monitoring the effectiveness of therapeutic modalities.
Collapse
Affiliation(s)
- Laura Daniela Ordierez Zúñiga
- University of Cauca, Electronics and Telecommunications Engineering Faculty, Electronics Deparment, Automation research group, Popayán, Colombia.
| | - Carlos Alberto Gaviria López
- University of Cauca, Electronics and Telecommunications Engineering Faculty, Electronics Deparment, Automation research group, Popayán, Colombia
| | - Elizabeth Roldán González
- Fundación Universitaria María Cano, Physiotherapy program, research group importance of movement of human development, Fisioter, Colombia
| |
Collapse
|
13
|
Liu K, Yin L, Ma Z, Yu B, Ma Y, Huang L. Effect of Different Kinesio Taping Interventions on the Local Thresholds of Current Perception and Pressure Pain in Healthy Adults. Front Physiol 2020; 11:596159. [PMID: 33281628 PMCID: PMC7689279 DOI: 10.3389/fphys.2020.596159] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 10/21/2020] [Indexed: 12/04/2022] Open
Abstract
Objective Previous studies made controversial claims about the alleged effects of Kinesio taping (KT) on pain relief. To date, the mechanism by which KT relieves pain remains unclear. Moreover, pain evaluation lacks objective and quantitative parameters. This study compared the acute effects of different KT interventions on the local thresholds of pressure pain and current perception in healthy adults to determine the potential mechanisms by which KT relieves pain. Methods Thirty healthy female subjects randomly received four KT interventions, namely, no taping (NT), placebo taping (PT), Y strips of KT (KY), and fan strips of KT (KF), on the waist. Current perception threshold (CPT), pressure pain threshold (PPT), soft tissue hardness, and the visual analog scale (VAS) scores of the subjects’ perceived pain were immediately measured after taping. Repeated-measures ANOVA was performed to determine significant differences in these parameters among the four interventions. Results Significant differences in CPT values among the interventions were observed at the frequency of 5 Hz (F = 3.499, p = 0.019, ηp2 = 0.111). Post hoc analysis revealed that CPT was significantly higher for KF than for NT (p = 0.008, 95% CI = 1.390–11.990). Significant differences in PPT values (F = 4.352, p = 0.012, ηp2 = 0.130) and soft tissue hardness (F = 2.957, p = 0.049, ηp2 = 0.093) were observed among the different taping conditions. Post hoc analysis revealed that PPT was significantly higher for KF than for PT (p = 0.011, 95% CI = 0.071–0.749), and soft tissue hardness was significantly higher for KF than for NT (p = 0.010, 95% CI = 0.461–4.586) and KY (p = 0.040, 95% CI = 0.059–3.800). No significant differences in self-perceived pain among the interventions were observed. Conclusion The healthy adult females had higher PPT values, lower soft tissue hardness, and higher CPT values at 5 Hz under KF intervention applied on the waist than those under the other taping interventions. Moreover, the different taping conditions had no significant differences in terms of VAS of perceived pain. These results provide guidance for the application of KT on pain management.
Collapse
Affiliation(s)
- Kun Liu
- Department of Rehabilitation Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Lulu Yin
- Department of Critical Care Medicine, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China
| | - Zheng Ma
- Department of Rehabilitation Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Bo Yu
- Department of Rehabilitation, School of International Medical Technology, Sanda University, Shanghai, China
| | - Yanhong Ma
- Department of Rehabilitation Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Lihua Huang
- Department of Rehabilitation Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| |
Collapse
|