1
|
Grasselli G, Arigò A, Palma P, Famiglini G, Cappiello A. Latest Developments in Direct and Non-Direct LC-MS Methods Based on Liquid Electron Ionization (LEI). Crit Rev Anal Chem 2024:1-18. [PMID: 39046707 DOI: 10.1080/10408347.2024.2381543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/25/2024]
Abstract
Mass spectrometry (MS) enables precise identification and quantification of molecules, particularly when combined with chromatography. The advent of atmospheric pressure ionization (API) techniques allowed the efficient coupling of liquid chromatography with MS (LC-MS), extending analyses to nonvolatile and thermolabile compounds. API techniques present limitations such as low informative capacity and reproducibility of mass spectra, increasing instrument complexity and costs. Other challenges include analyzing poorly polar molecules and matrix effects (ME), which negatively impact quantitative analyses, necessitating extensive sample purification or using expensive labeled standards. These limitations prompted the exploration of alternative solutions, leading to the development of the Liquid Electron Ionization (LEI) interface. The system has demonstrated excellent robustness and reproducibility. LEI has been employed to analyze various compounds, including pesticides, drugs of abuse, phenols, polycyclic aromatic hydrocarbons (PAHs), phthalates, and many others. Its versatility has been validated with single quadrupole, triple quadrupole, and QToF detectors, operating in electron ionization (EI) or chemical ionization (CI) modes and with both reverse phase liquid chromatography (RPLC) and normal phase liquid chromatography (NPLC). LEI has also been successfully integrated with the Microfluidic Open Interface (MOI), Membrane Introduction Mass Spectrometry (MIMS), and Microfluidic Water-Assisted Trap Focusing (M-WATF), broadening its application scope and consistently demonstrating promising results in terms of sensitivity and identification power. The most recent advancement is the development of Extractive-Liquid Sampling Electron Ionization-Mass Spectrometry (E-LEI-MS), a surface sampling and real-time analysis technique based on the LEI concept. This review article offers a comprehensive and up-to-date picture of the potential of LEI.
Collapse
Affiliation(s)
- Genny Grasselli
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Adriana Arigò
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Pierangela Palma
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Giorgio Famiglini
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Achille Cappiello
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| |
Collapse
|
2
|
Elkabets O, Neumark B, Amirav A. Sample Injection for Real-Time Analysis (SIRTA) Using GC-MS with Cold EI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:378-385. [PMID: 38234102 PMCID: PMC10853959 DOI: 10.1021/jasms.3c00412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 12/26/2023] [Accepted: 01/03/2024] [Indexed: 01/19/2024]
Abstract
There is a continual demand for advanced methods and instruments for real-time analysis (RTA). Most of the current RTA techniques based on MS involve ambient desorption ionization technology. However, flow injection of liquid extracted samples is another option without added modifications or cost to existing LC-MS instruments. In this work, we introduce a new RTA approach named sample injection for real-time analysis (SIRTA) using GC-MS with Cold EI. In SIRTA, the standard GC column is replaced with a 1 m long 0.1 mm I.D. fused silica capillary that connects the GC injector to the MS transfer-line of Cold EI. Thus, SIRTA with Cold EI imposes no need for any additional instrumentation; hence, it is characterized by zero added cost. Like in flow injection in MS of LC-MS, the sample is dissolved in ∼1 mL methanol or another solvent. Subsequently, the vial is placed in the GC-MS autosampler while using a standard syringe for injection without any GC separation. The analysis takes merely 0.2-0.7 min, ensuring rapid and consecutive analyses. Unlike standard EI, Cold EI enables SIRTA by taking advantage of its fly through open ion source to avoid overwhelming the ion source during the elution of solvents while still providing enhanced molecular ions for nearly all analytes. In this study, we demonstrated SIRTA Cold EI analysis of 12 compounds and 7 mixtures, including various prescription and illicit drugs, cannabis and petroleum samples, and other synthetic organic compounds including those with molecular weight up to 800 g/mol.
Collapse
Affiliation(s)
- Oneg Elkabets
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Benny Neumark
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Aviv Amirav
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
- Aviv
Analytical Ltd, 24 Hanagar
Street, Hod Hasharon 4527713, Israel
| |
Collapse
|
3
|
Pereira Dos Santos NG, Maciel EVS, Vargas Medina DA, Lanças FM. NanoLC-EI-MS: Perspectives in Biochemical Analysis. Int J Mol Sci 2023; 24:11746. [PMID: 37511506 PMCID: PMC10380556 DOI: 10.3390/ijms241411746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 07/14/2023] [Accepted: 07/18/2023] [Indexed: 07/30/2023] Open
Abstract
Although LC-MS with atmospheric pressure ionization (API) sources is the primary technique used in modern bioanalytical studies, electron ionization mass spectrometry (EI-MS) can provide some substantial advantages over it. EI-MS is a matrix effect-free technique that provides reproducible and comparable mass spectra, serving as a compound fingerprint for easy identification through automated comparison with spectral libraries. Leveraging EI-MS in biochemical studies can yield critical analytical benefits for targeted and untargeted analyses. However, to fully utilize EI-MS for heavy and non-volatile molecules, a new technology that enables the coupling of liquid chromatography with EI-MS is needed. Recent advancements in nanoLC have addressed the compatibility issues between LC and EI-MS, and innovative interfacing strategies such as Direct-EI, liquid electron ionization (LEI), and Cold-EI have extended the application of EI-MS beyond the determination of volatile organic molecules. This review provides an overview of the latest developments in nanoLC-EI-MS interfacing technologies, discussing their scope and limitations. Additionally, selected examples of nanoLC-EI-MS applications in the field of biochemical analysis are presented, highlighting the potential prospects and benefits that the establishment of this technique can bring to this field.
Collapse
Affiliation(s)
| | | | | | - Fernando Mauro Lanças
- Institute of Chemistry of São Carlos, University of São Paulo, São Carlos 13566-590, Brazil
| |
Collapse
|
4
|
Dagan S, Marder D, Tzanani N, Drug E, Prihed H, Yishai-Aviram L. Evaluation of Matrix Complexity in Nontargeted Analysis of Small-Molecule Toxicants by Liquid Chromatography-High-Resolution Mass Spectrometry. Anal Chem 2023; 95:7924-7932. [PMID: 37167435 DOI: 10.1021/acs.analchem.3c00413] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Complex mixtures, characterized by high density of compounds, challenge trace detection and identification. This is further exacerbated in nontargeted analysis, where a compound of interest may be well hidden under thousands of matrix compounds. We studied the effect of matrix complexity on nontargeted detection (peak picking) by LC-MS/MS (Orbitrap) analysis. A series of ∼20 drugs, V-type chemical warfare agents and pesticides, simulating toxic unknowns, were spiked at various concentrations in several complex matrices including urine, rosemary leaves, and soil extracts. Orbitrap "TraceFinder" software was used to explore their peak intensities in relation to the matrix (peak location in an intensity-sorted list). Average practical detection limits of nontargets were determined. While detection among the first 10,000 peaks was achieved at 0.3-1 ng/mL levels in the extract, for the more realistic "top 1000" list, much higher concentrations were required, approaching 10-30 ng/mL. A negative power law functional dependence between the peak location in an intensity-sorted suspect list and the nontarget concentration is proposed. Controlled complexity was explored with a series of urine dilutions, resulting in an excellent correlation between the power law coefficient and dilution factor. The intensity distribution of matrix peaks was found to spread (unevenly) on a broad range, fitting well the Weibull distribution function with all matrices and extracts. The quantitative approach demonstrated here gives a measure of the actual capabilities and limitations of LC-MS in the analysis of nontargets in complex matrices. It may be used to estimate and compare the complexity of matrices and predict the typical detection limits of unknowns.
Collapse
Affiliation(s)
- Shai Dagan
- Analytical Chemistry Department, Israel Institute for Biological Research (IIBR), Ness Ziona 7410001, Israel
| | - Dana Marder
- Analytical Chemistry Department, Israel Institute for Biological Research (IIBR), Ness Ziona 7410001, Israel
| | - Nitzan Tzanani
- Analytical Chemistry Department, Israel Institute for Biological Research (IIBR), Ness Ziona 7410001, Israel
| | - Eyal Drug
- Analytical Chemistry Department, Israel Institute for Biological Research (IIBR), Ness Ziona 7410001, Israel
| | - Hagit Prihed
- Analytical Chemistry Department, Israel Institute for Biological Research (IIBR), Ness Ziona 7410001, Israel
| | - Lilach Yishai-Aviram
- Analytical Chemistry Department, Israel Institute for Biological Research (IIBR), Ness Ziona 7410001, Israel
| |
Collapse
|
5
|
Enhanced microfluidic open interface for the direct coupling of solid phase microextraction with liquid electron ionization-tandem mass spectrometry. J Chromatogr A 2022; 1681:463479. [PMID: 36108353 DOI: 10.1016/j.chroma.2022.463479] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 09/01/2022] [Accepted: 09/04/2022] [Indexed: 11/21/2022]
Abstract
Solid-phase microextraction (SPME) directly coupled to MS is a widespread technique for determining small molecules in different matrices in many application fields. Here we present a modified microfluidic open interface (MOI) connected to a passive-flow-splitter device (PFS) for the direct coupling of SPME to a liquid-electron ionization (LEI) interface in a tandem mass spectrometer for the analysis of complex biological samples. No chromatographic separation is involved. The new MOI-PFS configuration was designed to speed up the sample transfer to MS, improving the signal-to-noise ratio and peak shape and leading to fast and sensitive results. MOI-PFS-LEI-MS/MS experiments were conducted using fentanyl as a model compound in water and blood serum. The method uses a C18 Bio-SPME fiber by direct immersion (3 min) in 300 µL of the sample followed by rapid desorption (1 min) in a flow isolated volume (MOI chamber, 2.5 µL) filled with 100% acetonitrile. The PFS permits the rapid transfer of a fraction of the sample into the MS via the LEI interface. The optimal conditions were obtained at a flow rate of 10 µL·min-1 and a 1:20 split ratio. Altogether, extraction, desorption, and analysis require approximately 5 min. Good interday and intraday precision, excellent linearity and LOQs in the µg·L-1 range were obtained for fentanyl in water and serum. Greenness evaluation demonstrated a limited environmental impact of this technique.
Collapse
|
6
|
Ma X. Recent Advances in Mass Spectrometry-Based Structural Elucidation Techniques. Molecules 2022; 27:molecules27196466. [PMID: 36235003 PMCID: PMC9572214 DOI: 10.3390/molecules27196466] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 09/23/2022] [Accepted: 09/26/2022] [Indexed: 11/17/2022] Open
Abstract
Mass spectrometry (MS) has become the central technique that is extensively used for the analysis of molecular structures of unknown compounds in the gas phase. It manipulates the molecules by converting them into ions using various ionization sources. With high-resolution MS, accurate molecular weights (MW) of the intact molecular ions can be measured so that they can be assigned a molecular formula with high confidence. Furthermore, the application of tandem MS has enabled detailed structural characterization by breaking the intact molecular ions and protonated or deprotonated molecules into key fragment ions. This approach is not only used for the structural elucidation of small molecules (MW < 2000 Da), but also crucial biopolymers such as proteins and polypeptides; therefore, MS has been extensively used in multiomics studies for revealing the structures and functions of important biomolecules and their interactions with each other. The high sensitivity of MS has enabled the analysis of low-level analytes in complex matrices. It is also a versatile technique that can be coupled with separation techniques, including chromatography and ion mobility, and many other analytical instruments such as NMR. In this review, we aim to focus on the technical advances of MS-based structural elucidation methods over the past five years, and provide an overview of their applications in complex mixture analysis. We hope this review can be of interest for a wide range of audiences who may not have extensive experience in MS-based techniques.
Collapse
Affiliation(s)
- Xin Ma
- School of Chemistry and Biochemistry, Georgia Institute of Technology, 901 Atlantic Dr NW, Atlanta, GA 30332, USA
| |
Collapse
|
7
|
Vargas Medina DA, Pereira dos Santos NG, Maciel EVS, Lanças FM. Current prospects on nano liquid chromatography coupled to electron ionization mass spectrometry (nanoLC-EI-MS). J LIQ CHROMATOGR R T 2022. [DOI: 10.1080/10826076.2022.2110114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
8
|
Maciel EVS, Pereira dos Santos NG, Vargas Medina DA, Lanças FM. Electron ionization mass spectrometry: Quo vadis? Electrophoresis 2022; 43:1587-1600. [DOI: 10.1002/elps.202100392] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 04/05/2022] [Accepted: 04/27/2022] [Indexed: 11/10/2022]
Affiliation(s)
| | | | | | - Fernando Mauro Lanças
- Institute of Chemistry of São Carlos University of São Paulo São Carlos São Paulo Brazil
| |
Collapse
|
9
|
Cappiello A, Termopoli V, Palma P, Famiglini G, Saeed M, Perry S, Navarro P. Liquid Chromatography-Electron Capture Negative Ionization-Tandem Mass Spectrometry Detection of Pesticides in a Commercial Formulation. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:141-148. [PMID: 34898195 PMCID: PMC8739837 DOI: 10.1021/jasms.1c00307] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 11/24/2021] [Accepted: 11/29/2021] [Indexed: 06/14/2023]
Abstract
Negative chemical ionization (NCI) and electron-capture negative ionization (ECNI) are gas chromatography-mass spectrometry (GC-MS) techniques that generate negative ions in the gas phase for compounds containing electronegative atoms or functional groups. In ECNI, gas-phase thermal electrons can be transferred to electrophilic substances to produce M-• ions and scarce fragmentation. As a result of the electrophilicity requirements, ECNI is characterized by high-specificity and low background noise, generally lower than EI, offering lower detection limits. The aim of this work is to explore the possibility of extending typical advantages of ECNI to liquid chromatography-mass spectrometry (LC-MS). The LC is combined with the novel liquid-EI (LEI) LC-EIMS interface, the eluent is vaporized and transferred inside a CI source, where it is mixed with methane as a buffer gas. As proof of concept, dicamba and tefluthrin, agrochemicals with herbicidal and insecticidal activity, respectively, were chosen as model compounds and detected together in a commercial formulation. The pesticides have different chemical properties, but both are suitable analytes for ECNI due to the presence of electronegative atoms in the molecules. The influence of the mobile phase and other LC- and MS-operative parameters were methodically evaluated. Part-per-trillion (ppt) detection limits were obtained. Ion abundances were found to be stable with quantitative linear detection, reliable, and reproducible, with no influence from coeluting interfering compounds from the sample matrix.
Collapse
Affiliation(s)
- Achille Cappiello
- University
of Urbino, Department of Pure
and Applied Sciences, LC−MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
- Department
of Chemistry, Vancouver Island University, Nanaimo, BC, Canada V9R 5S5
| | - Veronica Termopoli
- University
of Urbino, Department of Pure
and Applied Sciences, LC−MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - Pierangela Palma
- University
of Urbino, Department of Pure
and Applied Sciences, LC−MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
- Department
of Chemistry, Vancouver Island University, Nanaimo, BC, Canada V9R 5S5
| | - Giorgio Famiglini
- University
of Urbino, Department of Pure
and Applied Sciences, LC−MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - Mansoor Saeed
- Jealott’s
Hill International Research Centre, Syngenta, Bracknell, Berkshire RG42 6EY, U.K.
| | - Simon Perry
- Jealott’s
Hill International Research Centre, Syngenta, Bracknell, Berkshire RG42 6EY, U.K.
| | - Pablo Navarro
- Jealott’s
Hill International Research Centre, Syngenta, Bracknell, Berkshire RG42 6EY, U.K.
| |
Collapse
|
10
|
Famiglini G, Palma P, Termopoli V, Cappiello A. The history of electron ionization in LC-MS, from the early days to modern technologies: A review. Anal Chim Acta 2021; 1167:338350. [PMID: 34049632 DOI: 10.1016/j.aca.2021.338350] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 02/18/2021] [Accepted: 02/20/2021] [Indexed: 02/06/2023]
Abstract
This review article traces the history of the use of liquid chromatography coupled with mass spectrometry (LC-MS) using electron ionization (EI) from the first attempts up to the present day. At the time of the first efforts to couple LC to MS, 70 eV EI was the most common ionization technique, typically used in gas chromatography-mass spectrometry (GC-MS) and providing highly reproducible mass spectra that could be collated in libraries. Therefore, it was obvious to transport this dominant approach to the early LC-MS coupling attempts. The use of LC coupled to EI-MS is challenging mainly due to restrictions related to high-vacuum and high-temperature conditions required for the operation of EI and the need to remove the eluent carrying the analyte before entering the ion source. The authors will take readers through a journey of about 50 years, showing how through the succession of different attempts it has been possible to successfully couple LC with EI-MS, which in principle appear to be incompatible.
Collapse
Affiliation(s)
- Giorgio Famiglini
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino, Urbino, Italy.
| | - Pierangela Palma
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino, Urbino, Italy
| | - Veronica Termopoli
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino, Urbino, Italy
| | - Achille Cappiello
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino, Urbino, Italy.
| |
Collapse
|
11
|
Vargas Medina DA, Pereira Dos Santos NG, da Silva Burato JS, Borsatto JVB, Lanças FM. An overview of open tubular liquid chromatography with a focus on the coupling with mass spectrometry for the analysis of small molecules. J Chromatogr A 2021; 1641:461989. [PMID: 33611115 DOI: 10.1016/j.chroma.2021.461989] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 01/29/2021] [Accepted: 02/09/2021] [Indexed: 01/22/2023]
Abstract
Open tubular liquid chromatography (OT-LC) can provide superior chromatographic performance and more favorable mass spectrometry (MS) detection conditions. These features could provide enhanced sensitivity when coupled with electrospray ionization sources (ESI-) and lead to unprecedented detection capabilities if interfaced with a highly structural informative electron ionization (EI) source. In the past, the exploitation of OT columns in liquid chromatography evolved slowly. However, the recent instrumental developments in capillary/nanoLC-MS created new opportunities in developing and applying OT-LC-MS. Currently, the analytical advantages of OT-LC-MS are mainly exploited in the fields of proteomics and biosciences analysis. Nevertheless, under the right conditions, OT-LC-MS can also offer superior chromatographic performance and enhanced sensitivity in analyzing small molecules. This review will provide an overview of the latest developments in OT-LC-MS, focusing on the wide variety of employed separation mechanisms, innovative stationary phases, emerging column fabrication technologies, and new OT formats. In the same way, the OT-LC's opportunities and shortcomings coupled to both ESI and EI will be discussed, highlighting the complementary character of those two ionization modes to expand the LC's detection boundaries in the performance of targeted and untargeted studies.
Collapse
Affiliation(s)
| | | | | | | | - Fernando Mauro Lanças
- University of São Paulo, São Carlos, Institute of Chemistry of São Carlos, SP, Brazil.
| |
Collapse
|
12
|
Rocío-Bautista P, Famiglini G, Termopoli V, Palma P, Nazdrajić E, Pawliszyn J, Cappiello A. Direct Coupling of Bio-SPME to Liquid Electron Ionization-MS/MS via a Modified Microfluidic Open Interface. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:262-269. [PMID: 33213139 PMCID: PMC8016190 DOI: 10.1021/jasms.0c00303] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 11/04/2020] [Accepted: 11/11/2020] [Indexed: 05/25/2023]
Abstract
We present a modified microfluidic open interface (MOI) for the direct coupling of Bio-SPME to a liquid electron ionization-tandem mass spectrometry (LEI-MS/MS) system as a sensitive technique that can directly analyze biological samples without the need for sample cleanup or chromatographic separations as well as without measurable matrix effects (ME). We selected fentanyl as test compound. The method uses a C18 Bio-SPME fiber by direct immersion (DI) in urine and plasma and the subsequent quick desorption (1 min) in a flow-isolated volume (2.5 μL) filled with an internal standard-acetonitrile solution. The sample is then transferred to an EI source of a triple-quadrupole mass spectrometer via a LEI interface at a nanoscale flow rate. The desorption and analysis procedure requires less than 10 min. Up to 150 samples can be analyzed without observing a performance decline, with fentanyl quantitation at microgram-per-liter levels. The method workflow is extremely dependable, relatively fast, sustainable, and leads to reproducible results that enable the high-throughput screening of various biological samples.
Collapse
Affiliation(s)
- Priscilla Rocío-Bautista
- Department
of Chemistry, Life Sciences and Environmental Sustainability, University of Parma, 43121 Parma, Italy
- Department
of Pure and Applied Sciences, University
of Urbino, 61029 Urbino, Italy
| | - Giorgio Famiglini
- Department
of Pure and Applied Sciences, University
of Urbino, 61029 Urbino, Italy
| | - Veronica Termopoli
- Department
of Pure and Applied Sciences, University
of Urbino, 61029 Urbino, Italy
| | - Pierangela Palma
- Department
of Pure and Applied Sciences, University
of Urbino, 61029 Urbino, Italy
- Chemistry
Department, Vancouver Island University
VIU, Nanaimo, BC V9R5S5 Canada
| | - Emir Nazdrajić
- Department
of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department
of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Achille Cappiello
- Department
of Pure and Applied Sciences, University
of Urbino, 61029 Urbino, Italy
- Chemistry
Department, Vancouver Island University
VIU, Nanaimo, BC V9R5S5 Canada
| |
Collapse
|
13
|
Tsizin S, Fialkov AB, Amirav A. Analysis of impurities in pharmaceuticals by LC-MS with cold electron ionization. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4587. [PMID: 32662574 DOI: 10.1002/jms.4587] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 06/08/2020] [Accepted: 06/08/2020] [Indexed: 06/11/2023]
Abstract
Pharmaceuticals require careful and precise determination of their impurities that might harm the user upon consumption. Although today, the most common technique for impurities identification is liquid chromatography-mass spectrometry (LC-MS/MS), it has several downsides due to the nature of the ionization method. Also, the analyses in many cases are targeted thus despite being present, some of the compounds will not be revealed. In this paper, we propose and show a new method for untargeted analysis and identification of impurities in active pharmaceutical ingredients (APIs). The instrument used for these analyses is a novel electron ionization (EI) LC-MS with supersonic molecular beams (SMB). The EI-LC-MS-SMB was implemented for analyses of several drug samples spiked with an impurity. The instrument provides EI mass spectra with enhanced molecular ions, named Cold EI, which increases the identification probabilities when the compound is identified with the aid of an EI library like National Institute of Standards and Technology (NIST). We analyzed ibuprofen and its impurities, and both the API and the expected impurity were identified with names and structures by the NIST library. Moreover, other unexpected impurities were found and identified proving the ability of the EI-LC-MS-SMB system for truly untargeted analysis. The results show a broad dynamic range of four orders of magnitude at the same run with a signal-to-noise ratio of over 10 000 for the API and almost uniform response.
Collapse
Affiliation(s)
- Svetlana Tsizin
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | | | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| |
Collapse
|
14
|
Termopoli V, Famiglini G, Vocale P, Morini GL, Palma P, Rocío-Bautista P, Saeed M, Perry S, Cappiello A. Microfluidic water-assisted trap focusing method for ultra-large volume injection in reversed-phase nano-liquid chromatography coupled to electron ionization tandem-mass spectrometry. J Chromatogr A 2020; 1627:461421. [PMID: 32823116 DOI: 10.1016/j.chroma.2020.461421] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 07/16/2020] [Accepted: 07/18/2020] [Indexed: 10/23/2022]
Abstract
Herein we present an efficient, column-switching method that relies on a custom-made T-union passive diffusion micromixer to assist water dilution and promote trap solute focusing of a high sample volume dissolved in pure organic solvent using a 0.075 mm i.d. nano-LC column. This method allows injecting 20 μL (or higher) of sample volume, speeding up the analysis time, with a 400-fold increase of the limits of quantitation for selected compounds. Five pesticides in different media were used as model compounds, and the analyses were carried out with a triple quadrupole mass spectrometer equipped with a Liquid Electron Ionization (LEI) LC-MS interface working in multiple reaction monitoring (MRM) mode. The system microfluidics were investigated using COMSOL modeling software. Robustness of the entire system was evaluated using a post-extraction addition soil extracts with limits of detection values spanning from 0.10 to 0.45 µg/L. Reproducible results in terms of peak area, peak shape, and retention times were achieved in soil matrix. Repeatability test on peak area variations were lower than 10%.
Collapse
Affiliation(s)
- Veronica Termopoli
- Dipartimento di Scienze Pure ed Applicate, Università degli Studi di Urbino Carlo Bo, 61029, Urbino, Italy.
| | - Giorgio Famiglini
- Dipartimento di Scienze Pure ed Applicate, Università degli Studi di Urbino Carlo Bo, 61029, Urbino, Italy
| | - Pamela Vocale
- Dipartimento di Ingegneria e Architettura, Università degli Studi di Parma, 43124, Parma, Italy
| | - Gian Luca Morini
- Dipartimento di Ingegneria, Università degli Studi di Bologna, 40136, Bologna, Italy
| | - Pierangela Palma
- Dipartimento di Scienze Pure ed Applicate, Università degli Studi di Urbino Carlo Bo, 61029, Urbino, Italy; Chemistry Department, Vancouver Island University VIU, Nanaimo, BC, V9R5S5, Canada
| | - Priscilla Rocío-Bautista
- Dipartimento di Scienze Pure ed Applicate, Università degli Studi di Urbino Carlo Bo, 61029, Urbino, Italy
| | - Mansoor Saeed
- Syngenta Jealott's Hill International Research Center, RG42 6EY, Bracknell, UK
| | - Simon Perry
- Syngenta Jealott's Hill International Research Center, RG42 6EY, Bracknell, UK
| | - Achille Cappiello
- Dipartimento di Scienze Pure ed Applicate, Università degli Studi di Urbino Carlo Bo, 61029, Urbino, Italy; Chemistry Department, Vancouver Island University VIU, Nanaimo, BC, V9R5S5, Canada
| |
Collapse
|
15
|
Tsizin S, Fialkov AB, Amirav A. Electron Ionization Mass Spectrometry for Both Liquid and Gas Chromatography in One System without the Need for Hardware Adjustments. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1713-1721. [PMID: 32543199 DOI: 10.1021/jasms.0c00136] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A new instrument that bridges the gap between gas chromatography (GC) and liquid chromatography (LC) mass spectrometry (MS) was developed. In this instrument GC-MS and electron ionization LC-MS were combined in one MS system with method based mode changing. The LC pneumatic spray formation interface to MS was mounted on top of an otherwise unused GC detector slot and was connected with a flow restriction capillary to the MS through the GC oven and into the MS transfer line, parallel to the GC capillary column. The LC output mobile phase flow is directed into a spray formation and vaporization chamber. The pneumatic spray results in fine spray droplets that are thermally vaporized at a pressure equal to or greater than ambient. A portion of the vaporized mixture is directed into the heated flow restriction capillary that connects the spray formation and vaporization chamber into the electron ionization (EI) ion source, while most of the vaporized spray is released to the atmosphere. The combined GC-MS and LC-MS system can work either with standard EI or with cold EI via interfacing the flow restriction capillary into a supersonic nozzle forming a supersonic molecular beam of a vibrationally cold sample compound. We found that EI-LC-MS with cold EI has many benefits when compared with standard EI. The EI-LC-MS interface can also serve for flow injection analysis. The performance of the combined system is demonstrated in the analysis of a few sample mixtures by both GC-MS and LC-MS analysis, sequentially without hardware adjustments.
Collapse
Affiliation(s)
- Svetlana Tsizin
- School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel
| | | | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel
| |
Collapse
|
16
|
Vandergrift GW, Lattanzio-Battle W, Krogh ET, Gill CG. Condensed Phase Membrane Introduction Mass Spectrometry with In Situ Liquid Reagent Chemical Ionization in a Liquid Electron Ionization Source (CP-MIMS-LEI/CI). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:908-916. [PMID: 32154722 DOI: 10.1021/jasms.9b00143] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Direct mass spectrometry has grown significantly due to wide applicability, relative ease of use, and high sample throughput. However, many current direct mass spectrometry methods are largely based on ambient ionization techniques that can suffer from matrix effects and poor selectivity. A strategy that addresses these shortcomings is condensed phase membrane introduction mass spectrometry-liquid electron ionization utilizing in situ liquid reagent chemical ionization (CP-MIMS-LEI/CI). In CP-MIMS measurements, a semipermeable hollow fiber polydimethylsiloxane membrane probe is directly immersed into a complex sample. Neutral, hydrophobic analytes permeating the membrane are entrained by a continuously flowing liquid acceptor phase (nL/min) to an LEI/CI source, where the liquid is nebulized, followed by analyte vaporization and ionization. This study marks the first intentional exploitation of the liquid CP-MIMS acceptor phase as an in situ means of providing liquid chemical ionization (CI) reagents for improved analyte sensitivity and selectivity (CP-MIMS-LEI/CI). Acetonitrile and diethyl ether were used as a combination acceptor phase/CI proton transfer reagent system for the direct analysis of dialkyl phthalates. Using isotopically labeled reagents, the gas phase ionization mechanism was found to involve reagent autoprotonation, followed by proton transfer to dialkyl phthalates. A demonstration of the applicability of CP-MIMS-LEI/CI for rapid and sensitive screening of bis(2-ethylhexyl) phthalate in house dust samples is presented. The detection limit in house dust (6 mg/kg) is comparable to that obtained by conventional analyses, but without time-consuming sample workup or chromatographic separation steps.
Collapse
Affiliation(s)
- Gregory W Vandergrift
- Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, Nanaimo, BC Canada, V9R 5S5
- Chemistry Department, University of Victoria, Victoria, BC Canada, V8P 5C2
| | - William Lattanzio-Battle
- Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, Nanaimo, BC Canada, V9R 5S5
| | - Erik T Krogh
- Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, Nanaimo, BC Canada, V9R 5S5
- Chemistry Department, University of Victoria, Victoria, BC Canada, V8P 5C2
| | - Chris G Gill
- Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, Nanaimo, BC Canada, V9R 5S5
- Chemistry Department, University of Victoria, Victoria, BC Canada, V8P 5C2
- Chemistry Department, Simon Fraser University, Burnaby, BC Canada, V5A 1S6
- Environmental and Occupational Health Sciences Department, University of Washington, Seattle, Washington 98195, United States
| |
Collapse
|
17
|
Margolin Eren KJ, Fialkov AB, Keshet U, Tsizin S, Amirav A. Doubly Charged Molecular Ions in GC-MS with Cold EI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:347-354. [PMID: 32031407 DOI: 10.1021/jasms.9b00067] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
We report the finding of doubly charged molecular ions in a range of relatively large molecules including hydrocarbons upon their electron ionization as vibrationally cold molecules in supersonic molecular beams (SMB) (also named as Cold EI). Furthermore, we also report the detection by mass spectrometry of triply charged molecular ions in large PAHs such as decacyclene and ovalene upon their cooling in SMB. We found that the relative abundance of doubly charged molecular ions strongly depends on the internal vibrational cooling. While after some vibrational cooling the fragmentation pattern became cooling independent, the relative abundance of the doubly charged molecular ions was noticeably increased upon further cooling via increasing of the cooling make-up gas flow rate. In addition, the relative abundance of the doubly charged molecular ions was strongly increased with the compounds' size, and its electron energy threshold was lower than expected. These observations indicate a new mechanism that involves two separate electron ionization processes in the same compound, most likely with the same electron but at two separate atoms (places) in large molecules, to reduce Coulombic repulsion energy that can lead to fragmentation into two singly charged ions. These findings are shedding new light on electron ionization mass spectra. Accordingly, electron ionization mass spectra are the result of three separate mechanisms with relative magnitudes that depend on the compound size: (a) single electron ionization; (b) double electron ionization; and (c) single electron ionization with subsequent internal excitation by the same ionizing electron in another place.
Collapse
Affiliation(s)
| | | | - Uri Keshet
- School of Chemistry , Tel Aviv University , Tel Aviv 6997801 , Israel
| | - Svetlana Tsizin
- School of Chemistry , Tel Aviv University , Tel Aviv 6997801 , Israel
| | - Aviv Amirav
- School of Chemistry , Tel Aviv University , Tel Aviv 6997801 , Israel
- Aviv Analytical Ltd. , 24 Hanagar Street Hod , Hasharon 4527713 , Israel
| |
Collapse
|
18
|
Beccaria M, Cabooter D. Current developments in LC-MS for pharmaceutical analysis. Analyst 2020; 145:1129-1157. [DOI: 10.1039/c9an02145k] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Liquid chromatography (LC) based techniques in combination with mass spectrometry (MS) detection have had a large impact on the development of new pharmaceuticals in the past decades.
Collapse
Affiliation(s)
- Marco Beccaria
- KU Leuven
- Department for Pharmaceutical and Pharmacological Sciences
- Pharmaceutical Analysis
- Leuven
- Belgium
| | - Deirdre Cabooter
- KU Leuven
- Department for Pharmaceutical and Pharmacological Sciences
- Pharmaceutical Analysis
- Leuven
- Belgium
| |
Collapse
|
19
|
Rigano F, Tranchida PQ, Dugo P, Mondello L. High-performance liquid chromatography combined with electron ionization mass spectrometry: A review. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.05.032] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
20
|
Evaluation of a liquid electron ionization liquid chromatography-mass spectrometry interface. J Chromatogr A 2019; 1591:120-130. [PMID: 30660440 DOI: 10.1016/j.chroma.2019.01.034] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 12/20/2018] [Accepted: 01/11/2019] [Indexed: 11/27/2022]
Abstract
Liquid Electron Ionization (LEI), is an innovative liquid chromatography-mass spectrometry (LC-MS) interface that converts liquid HPLC eluent to the gas-phase in a mass spectrometer equipped with an electron ionization (EI) source. LEI extends the electronic spectra libraries access to liquid chromatography, providing a powerful tool in the untargeted approacssh. Negligible matrix effects allow accurate quantitative information. The purpose of this research was to evaluate the main aspects concerning the interfacing process. These fundamental studies were necessary to understand the mechanism of LEI in details, and improve the interfacing process, especially regarding robustness and sensitivity. Hardware components were installed to prevent analytes precipitation, reduce thermal decomposition of sensitive compounds, and to stabilize the nano-flow delivery with different mobile-phase compositions. Particular attention was devoted to insulating the heated vaporization area from the LC part of the system. Experiments were performed to optimize the interface inner capillary dimensions, and other operative parameters, including temperature, gas and liquid flow rates. Test compounds of environmental interest were selected based on molecular weight, thermal stability, volatility, and polarity. Robustness was evaluated with a set of replicated injections and calibration experiments using a soil matrix as a test sample. MRM detection limits in the low-picogram range were obtained for five pesticides belonging to different classes in a soil sample. High-quality electron ionization mass spectra of a mixture of pesticides were also obtained.
Collapse
|
21
|
Vandergrift GW, Monaghan J, Krogh ET, Gill CG. Direct Analysis of Polyaromatic Hydrocarbons in Soil and Aqueous Samples Using Condensed Phase Membrane Introduction Tandem Mass Spectrometry with Low-Energy Liquid Electron Ionization. Anal Chem 2018; 91:1587-1594. [DOI: 10.1021/acs.analchem.8b04949] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Gregory W. Vandergrift
- Applied Environmental
Research Laboratories, Chemistry Department, Vancouver Island University, Nanaimo, British Columbia, Canada, V9R 5S5
- Chemistry Department, University of Victoria, Victoria, British Columbia, Canada, V8P 5C2
| | - Joseph Monaghan
- Applied Environmental
Research Laboratories, Chemistry Department, Vancouver Island University, Nanaimo, British Columbia, Canada, V9R 5S5
| | - Erik T. Krogh
- Applied Environmental
Research Laboratories, Chemistry Department, Vancouver Island University, Nanaimo, British Columbia, Canada, V9R 5S5
- Chemistry Department, University of Victoria, Victoria, British Columbia, Canada, V8P 5C2
| | - Chris G. Gill
- Applied Environmental
Research Laboratories, Chemistry Department, Vancouver Island University, Nanaimo, British Columbia, Canada, V9R 5S5
- Chemistry Department, University of Victoria, Victoria, British Columbia, Canada, V8P 5C2
- Chemistry Department, Simon Fraser University, Burnaby, British Columbia, Canada, V5A 1S6
- Environmental and Occupational Health Sciences Department, University of Washington, Seattle, Washington 98195, United States
| |
Collapse
|
22
|
Hits and misses in research trends to monitor contaminants in foods. Anal Bioanal Chem 2018; 410:5331-5351. [DOI: 10.1007/s00216-018-1195-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Revised: 05/31/2018] [Accepted: 06/12/2018] [Indexed: 01/26/2023]
|
23
|
Bianchi F, Riboni N, Termopoli V, Mendez L, Medina I, Ilag L, Cappiello A, Careri M. MS-Based Analytical Techniques: Advances in Spray-Based Methods and EI-LC-MS Applications. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2018; 2018:1308167. [PMID: 29850370 PMCID: PMC5937452 DOI: 10.1155/2018/1308167] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Accepted: 02/26/2018] [Indexed: 05/15/2023]
Abstract
Mass spectrometry is the most powerful technique for the detection and identification of organic compounds. It can provide molecular weight information and a wealth of structural details that give a unique fingerprint for each analyte. Due to these characteristics, mass spectrometry-based analytical methods are showing an increasing interest in the scientific community, especially in food safety, environmental, and forensic investigation areas where the simultaneous detection of targeted and nontargeted compounds represents a key factor. In addition, safety risks can be identified at the early stage through online and real-time analytical methodologies. In this context, several efforts have been made to achieve analytical instrumentation able to perform real-time analysis in the native environment of samples and to generate highly informative spectra. This review article provides a survey of some instrumental innovations and their applications with particular attention to spray-based MS methods and food analysis issues. The survey will attempt to cover the state of the art from 2012 up to 2017.
Collapse
Affiliation(s)
- Federica Bianchi
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
| | - Nicolò Riboni
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
- Department of Environmental Science and Analytical Chemistry, Stockholm University, 10691 Stockholm, Sweden
| | - Veronica Termopoli
- Department of Pure and Applied Sciences, LC-MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - Lucia Mendez
- Instituto de Investigaciones Marinas, Spanish National Research Council (IIM-CSIC), Eduardo Cabello 6, 36208 Vigo, Spain
| | - Isabel Medina
- Instituto de Investigaciones Marinas, Spanish National Research Council (IIM-CSIC), Eduardo Cabello 6, 36208 Vigo, Spain
| | - Leopold Ilag
- Department of Environmental Science and Analytical Chemistry, Stockholm University, 10691 Stockholm, Sweden
| | - Achille Cappiello
- Department of Pure and Applied Sciences, LC-MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - Maria Careri
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
| |
Collapse
|
24
|
Electron Ionization LC-MS. ADVANCES IN THE USE OF LIQUID CHROMATOGRAPHY MASS SPECTROMETRY (LC-MS) - INSTRUMENTATION DEVELOPMENTS AND APPLICATIONS 2018. [DOI: 10.1016/bs.coac.2017.06.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
25
|
Tsizin S, Seemann B, Alon T, Amirav A. Second hydrogen atom abstraction by molecular ions. JOURNAL OF MASS SPECTROMETRY : JMS 2017; 52:638-642. [PMID: 28685904 DOI: 10.1002/jms.3966] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 06/25/2017] [Accepted: 07/03/2017] [Indexed: 06/07/2023]
Abstract
We report the observation of a new physical phenomenon of the addition of 2 hydrogen atoms to molecular ions thus forming [M + 2H]+ ions. We demonstrate such second hydrogen atom abstraction onto the molecular ions of pentaerythritol and trinitrotoluene (TNT). We used both gas chromatography mass spectrometry (GC-MS) with supersonic molecular beam (SMB) with methanol added into its make-up gas and electron ionization (EI) liquid chromatography mass spectrometry (LC-MS) with SMB with methanol as the LC solvent. We found that the formation of methanol clusters resulted upon EI in the formation of dominant protonated pentaerythritol ion at m/z = 137 plus about 70% relative abundance of pentaerythritol molecular ion with 2 additional hydrogen atoms at m/z = 138 which is well above the 5.7% natural C13 isotope abundance of protonated pentaerythritol. Similarly, we found an abundant protonated TNT ion at m/z = 228 and a similar abundance of TNT molecular ion with 2 additional hydrogen atoms at m/z = 229. Upon the use of deuterated methanol (CD3 OD) as the solvent, we observed an abundant m/z = 231 (M + 2D)+ of TNT with 2 deuterium atoms. We found such abundant second hydrogen atom abstraction with butylglycolate and at low abundances in dioctylphthalate, Vitamin K3, phenazine, and RDX. At this time, we are unable to report the magnitude and frequency of occurrence of this phenomenon in standard electrospray LC-MS. This observation could have important implications on the provision of elemental formula from mass spectra that are involved with protonated molecules. Accordingly, while accurate mass measurements can serve for the generation of elemental formula, their further support and improvement via isotope abundance analysis are questionable. Consequently, if a given compound can be analyzed by both GC-MS and LC-MS, its GC-MS analysis can be superior for the provision of accurate elemental formulae if its EI mass spectrum exhibits abundant molecular ions such as with GC-MS with SMB (also known as cold EI).
Collapse
Affiliation(s)
- Svetlana Tsizin
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - Boaz Seemann
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - Tal Alon
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| |
Collapse
|
26
|
Jarrell TM, Owen BC, Riedeman JS, Prentice BM, Pulliam CJ, Max J, Kenttämaa HI. Laser-Induced Acoustic Desorption/Electron Ionization of Amino Acids and Small Peptides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1091-1098. [PMID: 28500583 DOI: 10.1007/s13361-017-1684-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Revised: 04/05/2017] [Accepted: 04/07/2017] [Indexed: 06/07/2023]
Abstract
Laser-induced acoustic desorption (LIAD) allows for desorption of neutral nonvolatile compounds independent of their volatility or thermal stability. Many different ionization methods have been coupled with LIAD. Hence, this setup provides a better control over the types of ions formed than other mass spectrometry evaporation/ionization methods commonly used to characterize biomolecules, such as ESI or MALDI. In this study, the utility of LIAD coupled with electron ionization (EI) was tested for the analysis of common amino acids with no derivatization. The results compared favorably with previously reported EI mass spectra obtained using thermal desorption/EI. Further, LIAD/EI mass spectra collected for hydrochloride salts of two amino acids were found to be similar to those measured for the neutral amino acids with the exception of the appearance of an HCl+● ion. However, the hydrochloride salt of arginine showed a distinctly different LIAD/EI mass spectrum than the previously published literature EI mass spectrum, likely due to its highly basic side chain that makes a specific zwitterionic form particularly favorable. Finally, EI mass spectra were measured for seven small peptides, including di-, tri-, and tetrapeptides. These mass spectra show a variety of ion types. However, an type ions are prevalent. Also, electron-induced dissociation (EID) of protonated peptides has been reported to form primarily an type ions. In addition, the loss of small neutral molecules and side-chain cleavages were observed that are reminiscent of other high-energy fragmentation methods, such as EID. Finally, the isomeric dipeptides LG and IG were found to produce drastically different EI mass spectra, thus allowing differentiation of the leucine and isoleucine amino acids in these dipeptides. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Tiffany M Jarrell
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Benjamin C Owen
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - James S Riedeman
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Boone M Prentice
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Chris J Pulliam
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Joann Max
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Hilkka I Kenttämaa
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA.
| |
Collapse
|
27
|
Termopoli V, Famiglini G, Palma P, Piergiovanni M, Cappiello A. Atmospheric Pressure Vaporization Mechanism for Coupling a Liquid Phase with Electron Ionization Mass Spectrometry. Anal Chem 2017; 89:2049-2056. [PMID: 28208289 DOI: 10.1021/acs.analchem.6b04646] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A novel liquid chromatography-mass spectrometry (LC-MS) interfacing concept is presented and discussed. The new interface, called liquid-EI (LEI), is based on electron ionization (EI) but, differently from any previous attempt, the vaporization of solutes and mobile phase takes place at atmospheric pressure into a specifically designed region, called "vaporization microchannel", before entering the high-vacuum ion source. The interface is completely independent from the rest of the instrumentation and can be adapted to any gas chromatography/mass spectrometry (GC/MS) system, as an add-on for a rapid LC-MS conversion. Pressure drop and temperature gradient between LC and MS were considered to enhance the analyte response and reduce band broadening and/or solute carryovers. A fused silica liner, placed inside the vaporization microchannel, acts as an inert vaporization surface speeding up the gas-phase conversion of large molecules while lessening possible memory effects. The liner is easily replaceable for a quick and extremely simple interface maintenance. Proof of concept and detailed description of the interface are here presented.
Collapse
Affiliation(s)
- Veronica Termopoli
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino , Urbino, Italy
| | - Giorgio Famiglini
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino , Urbino, Italy
| | - Pierangela Palma
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino , Urbino, Italy
| | - Maurizio Piergiovanni
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino , Urbino, Italy
| | - Achille Cappiello
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino , Urbino, Italy
| |
Collapse
|
28
|
Nanita SC, Kaldon LG. Emerging flow injection mass spectrometry methods for high-throughput quantitative analysis. Anal Bioanal Chem 2015; 408:23-33. [PMID: 26670771 DOI: 10.1007/s00216-015-9193-1] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2015] [Revised: 11/07/2015] [Accepted: 11/12/2015] [Indexed: 01/07/2023]
Abstract
Where does flow injection analysis mass spectrometry (FIA-MS) stand relative to ambient mass spectrometry (MS) and chromatography-MS? Improvements in FIA-MS methods have resulted in fast-expanding uses of this technique. Key advantages of FIA-MS over chromatography-MS are fast analysis (typical run time <60 s) and method simplicity, and FIA-MS offers high-throughput without compromising sensitivity, precision and accuracy as much as ambient MS techniques. Consequently, FIA-MS is increasingly becoming recognized as a suitable technique for applications where quantitative screening of chemicals needs to be performed rapidly and reliably. The FIA-MS methods discussed herein have demonstrated quantitation of diverse analytes, including pharmaceuticals, pesticides, environmental contaminants, and endogenous compounds, at levels ranging from parts-per-billion (ppb) to parts-per-million (ppm) in very complex matrices (such as blood, urine, and a variety of foods of plant and animal origin), allowing successful applications of the technique in clinical diagnostics, metabolomics, environmental sciences, toxicology, and detection of adulterated/counterfeited goods. The recent boom in applications of FIA-MS for high-throughput quantitative analysis has been driven in part by (1) the continuous improvements in sensitivity and selectivity of MS instrumentation, (2) the introduction of novel sample preparation procedures compatible with standalone mass spectrometric analysis such as salting out assisted liquid-liquid extraction (SALLE) with volatile solutes and NH4(+) QuEChERS, and (3) the need to improve efficiency of laboratories to satisfy increasing analytical demand while lowering operational cost. The advantages and drawbacks of quantitative analysis by FIA-MS are discussed in comparison to chromatography-MS and ambient MS (e.g., DESI, LAESI, DART). Generally, FIA-MS sits 'in the middle' between ambient MS and chromatography-MS, offering a balance between analytical capability and sample analysis throughput suitable for broad applications in life sciences, agricultural chemistry, consumer safety, and beyond.
Collapse
Affiliation(s)
- Sergio C Nanita
- DuPont Crop Protection, Stine-Haskell Research Center, 1090 Elkton Road, Newark, DE, 19714, USA.
| | - Laura G Kaldon
- DuPont Crop Protection, Stine-Haskell Research Center, 1090 Elkton Road, Newark, DE, 19714, USA
| |
Collapse
|