1
|
Vedam-Mai V, Samuel JM, Prentice BM. Imaging mass spectrometry: a molecular microscope for studying the role of lipids in Parkinson's disease. Neural Regen Res 2024; 19:1179-1180. [PMID: 37905853 DOI: 10.4103/1673-5374.385862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 08/25/2023] [Indexed: 11/02/2023] Open
Affiliation(s)
- Vinata Vedam-Mai
- Department of Neurology, University of Florida, Gainesville, FL, USA (Vedam-Mai V)
| | - Jacob M Samuel
- Department of Chemistry, University of Florida, Gainesville, FL, USA (Samuel JM, Prentice BM)
| | - Boone M Prentice
- Department of Chemistry, University of Florida, Gainesville, FL, USA (Samuel JM, Prentice BM)
| |
Collapse
|
2
|
Prentice BM. Imaging with mass spectrometry: Which ionization technique is best? J Mass Spectrom 2024; 59:e5016. [PMID: 38625003 DOI: 10.1002/jms.5016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/07/2024] [Accepted: 02/21/2024] [Indexed: 04/17/2024]
Abstract
The use of mass spectrometry (MS) to acquire molecular images of biological tissues and other substrates has developed into an indispensable analytical tool over the past 25 years. Imaging mass spectrometry technologies are widely used today to study the in situ spatial distributions for a variety of analytes. Early MS images were acquired using secondary ion mass spectrometry and matrix-assisted laser desorption/ionization. Researchers have also designed and developed other ionization techniques in recent years to probe surfaces and generate MS images, including desorption electrospray ionization (DESI), nanoDESI, laser ablation electrospray ionization, and infrared matrix-assisted laser desorption electrospray ionization. Investigators now have a plethora of ionization techniques to select from when performing imaging mass spectrometry experiments. This brief perspective will highlight the utility and relative figures of merit of these techniques within the context of their use in imaging mass spectrometry.
Collapse
Affiliation(s)
- Boone M Prentice
- Department of Chemistry, University of Florida, Gainesville, Florida, USA
| |
Collapse
|
3
|
Ellin NR, Guo Y, Miranda-Quintana RA, Prentice BM. Extended similarity methods for efficient data mining in imaging mass spectrometry. Digit Discov 2024; 3:805-817. [PMID: 38638647 PMCID: PMC11022984 DOI: 10.1039/d3dd00165b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 03/19/2024] [Indexed: 04/20/2024]
Abstract
Imaging mass spectrometry is a label-free imaging modality that allows for the spatial mapping of many compounds directly in tissues. In an imaging mass spectrometry experiment, a raster of the tissue surface produces a mass spectrum at each sampled x, y position, resulting in thousands of individual mass spectra, each comprising a pixel in the resulting ion images. However, efficient analysis of imaging mass spectrometry datasets can be challenging due to the hyperspectral characteristics of the data. Each spectrum contains several thousand unique compounds at discrete m/z values that result in unique ion images, which demands robust and efficient algorithms for searching, statistical analysis, and visualization. Some traditional post-processing techniques are fundamentally ill-equipped to dissect these types of data. For example, while principal component analysis (PCA) has long served as a useful tool for mining imaging mass spectrometry datasets to identify correlated analytes and biological regions of interest, the interpretation of the PCA scores and loadings can be non-trivial. The loadings often contain negative peaks in the PCA-derived pseudo-spectra, which are difficult to ascribe to underlying tissue biology. Herein, we have utilized extended similarity indices to streamline the interpretation of imaging mass spectrometry data. This novel workflow uses PCA as a pixel-selection method to parse out the most and least correlated pixels, which are then compared using the extended similarity indices. The extended similarity indices complement PCA by removing all non-physical artifacts and streamlining the interpretation of large volumes of imaging mass spectrometry spectra simultaneously. The linear complexity, O(N), of these indices suggests that large imaging mass spectrometry datasets can be analyzed in a 1 : 1 scale of time and space with respect to the size of the input data. The extended similarity indices algorithmic workflow is exemplified here by identifying discrete biological regions of mouse brain tissue.
Collapse
Affiliation(s)
- Nicholas R Ellin
- Department of Chemistry, University of Florida Gainesville FL 32611-7200 USA
| | - Yingchan Guo
- Department of Chemistry, University of Florida Gainesville FL 32611-7200 USA
| | - Ramón Alain Miranda-Quintana
- Department of Chemistry, University of Florida Gainesville FL 32611-7200 USA
- Quantum Theory Project, University of Florida Gainesville FL 32611-7200 USA
| | - Boone M Prentice
- Department of Chemistry, University of Florida Gainesville FL 32611-7200 USA
| |
Collapse
|
4
|
Scoggins TR, Specker JT, Prentice BM. Multiple ion isolation and accumulation events for selective chemical noise reduction and dynamic range enhancement in MALDI imaging mass spectrometry. Analyst 2024; 149:2459-2468. [PMID: 38525787 DOI: 10.1039/d4an00160e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2024]
Abstract
Abundant chemical noise in MALDI imaging mass spectrometry experiments can impede the detection of less abundant compounds of interest. This chemical noise commonly originates from the MALDI matrix as well as other endogenous compounds present in high concentrations and/or with high ionization efficiencies. MALDI imaging mass spectrometry of biological tissues measures numerous biomolecular compounds that exist in a wide range of concentrations in vivo. When ion trapping instruments are used, highly abundant ions can dominate the charge capacity and lead to space charge effects that hinder the dynamic range and detection of lowly abundant compounds of interest. Gas-phase fractionation has been previously utilized in mass spectrometry to isolate and enrich target analytes. Herein, we have characterized the use of multiple continuous accumulations of selected ions (Multi CASI) to reduce the abundance of chemical noise and diminish the effects of space charge in MALDI imaging mass spectrometry experiments. Multi CASI utilizes the mass-resolving capability of a quadrupole mass filter to perform multiple sequential ion isolation events prior to a single mass analysis of the combined ion population. Multi CASI was used to improve metabolite and lipid detection in the MALDI imaging mass spectrometry analysis of rat brain tissue.
Collapse
Affiliation(s)
- Troy R Scoggins
- Department of Chemistry, University of Florida, Gainesville, FL, USA.
| | | | - Boone M Prentice
- Department of Chemistry, University of Florida, Gainesville, FL, USA.
| |
Collapse
|
5
|
Liang Z, Guo Y, Ellin N, King TI, Berthold EC, Mukhopadhyay S, Sharma A, McCurdy CR, Prentice BM. Formation of multiple ion types during MALDI imaging mass spectrometry analysis of Mitragyna speciosa alkaloids in dosed rat brain tissue. Talanta 2024; 274:125923. [PMID: 38569366 DOI: 10.1016/j.talanta.2024.125923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Revised: 03/08/2024] [Accepted: 03/13/2024] [Indexed: 04/05/2024]
Abstract
Mitragyna speciosa, more commonly known as kratom, has emerged as an alternative to treat chronic pain and addiction. However, the alkaloid components of kratom, which are the major contributors to kratom's pharmaceutical properties, have not yet been fully investigated. In this study, matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry was used to map the biodistribution of three alkaloids (corynantheidine, mitragynine, and speciogynine) in rat brain tissues. The alkaloids produced three main ion types during MALDI analysis: [M + H]+, [M - H]+, and [M - 3H]+. Contrary to previous reports suggesting that the [M - H]+ and [M - 3H]+ ion types form during laser ablation, these ion types can also be produced during the MALDI matrix application process. Several strategies are proposed to accurately map the biodistribution of the alkaloids. Due to differences in the relative abundances of the ions in different biological regions of the tissue, differences in ionization efficiencies of the ions, and potential overlap of the [M - H]+ and [M - 3H]+ ion types with endogenous metabolites of the same empirical formula, a matrix that mainly produces the [M + H]+ ion type is optimal for accurate mapping of the alkaloids. Alternatively, the most abundant ion type can be mapped or the intensities of all ion types can be summed together to generate a composite image. The accuracy of each of these approaches is explored and validated.
Collapse
Affiliation(s)
- Zhongling Liang
- Department of Chemistry, University of Florida, Gainesville, FL 32611, USA
| | - Yingchan Guo
- Department of Chemistry, University of Florida, Gainesville, FL 32611, USA
| | - Nicholas Ellin
- Department of Chemistry, University of Florida, Gainesville, FL 32611, USA
| | - Tamara I King
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Gainesville, FL 32610, USA
| | - Erin C Berthold
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Gainesville, FL 32610, USA
| | - Sushobhan Mukhopadhyay
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Gainesville, FL 32610, USA; Department of Medicinal Chemistry, College of Pharmacy, University of Florida, Gainesville, FL 32610, USA
| | - Abhisheak Sharma
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Gainesville, FL 32610, USA
| | - Christopher R McCurdy
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Gainesville, FL 32610, USA; Department of Medicinal Chemistry, College of Pharmacy, University of Florida, Gainesville, FL 32610, USA
| | - Boone M Prentice
- Department of Chemistry, University of Florida, Gainesville, FL 32611, USA.
| |
Collapse
|
6
|
Liang Z, Guo Y, Sharma A, McCurdy CR, Prentice BM. A multi-modal image fusion workflow incorporating MALDI imaging mass spectrometry and microscopy for the study of small pharmaceutical compounds. bioRxiv 2024:2024.03.12.584673. [PMID: 38559145 PMCID: PMC10980041 DOI: 10.1101/2024.03.12.584673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Multi-modal imaging analyses of dosed tissue samples can provide more comprehensive insight into the effects of a therapeutically active compound on a target tissue compared to single-modal imaging. For example, simultaneous spatial mapping of pharmaceutical compounds and endogenous macromolecule receptors is difficult to achieve in a single imaging experiment. Herein, we present a multi-modal workflow combining imaging mass spectrometry with immunohistochemistry (IHC) fluorescence imaging and brightfield microscopy imaging. Imaging mass spectrometry enables direct mapping of pharmaceutical compounds and metabolites, IHC fluorescence imaging can visualize large proteins, and brightfield microscopy imaging provides tissue morphology information. Single-cell resolution images are generally difficult to acquire using imaging mass spectrometry, but are readily acquired with IHC fluorescence and brightfield microscopy imaging. Spatial sharpening of mass spectrometry images would thus allow for higher fidelity co-registration with higher resolution microscopy images. Imaging mass spectrometry spatial resolution can be predicted to a finer value via a computational image fusion workflow, which models the relationship between the intensity values in the mass spectrometry image and the features of a high spatial resolution microscopy image. As a proof of concept, our multi-modal workflow was applied to brain tissue extracted from a Sprague Dawley rat dosed with a kratom alkaloid, corynantheidine. Four candidate mathematical models including linear regression, partial least squares regression (PLS), random forest regression, and two-dimensional convolutional neural network (2-D CNN), were tested. The random forest and 2-D CNN models most accurately predicted the intensity values at each pixel as well as the overall patterns of the mass spectrometry images, while also providing the best spatial resolution enhancements. Herein, image fusion enabled predicted mass spectrometry images of corynantheidine, GABA, and glutamine to approximately 2.5 μm spatial resolutions, a significant improvement compared to the original images acquired at 25 μm spatial resolution. The predicted mass spectrometry images were then co-registered with an H&E image and IHC fluorescence image of the μ-opioid receptor to assess co-localization of corynantheidine with brain cells. Our study also provides insight into the different evaluation parameters to consider when utilizing image fusion for biological applications.
Collapse
Affiliation(s)
- Zhongling Liang
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| | - Yingchan Guo
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| | - Abhisheak Sharma
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Gainesville, FL 32610
| | - Christopher R. McCurdy
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Gainesville, FL 32610
- Department of Medicinal Chemistry, College of Pharmacy, University of Florida, Gainesville, FL 32610
| | - Boone M. Prentice
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| |
Collapse
|
7
|
Smith AB, Specker JT, Hewlett KK, Scoggins TR, Knight M, Lustig AM, Li Y, Evans KM, Guo Y, She Q, Christopher MW, Garrett TJ, Moustafa AM, Van Tyne D, Prentice BM, Zackular JP. Liberation of host heme by Clostridioides difficile-mediated damage enhances Enterococcus faecalis fitness during infection. mBio 2024; 15:e0165623. [PMID: 38078767 PMCID: PMC10790701 DOI: 10.1128/mbio.01656-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 10/23/2023] [Indexed: 01/17/2024] Open
Abstract
IMPORTANCE Clostridioides difficile and Enterococcus faecalis are two pathogens of great public health importance. Both bacteria colonize the human gastrointestinal tract where they are known to interact in ways that worsen disease outcomes. We show that the damage associated with C. difficile infection (CDI) releases nutrients that benefit E. faecalis. One particular nutrient, heme, allows E. faecalis to use oxygen to generate energy and grow better in the gut. Understanding the mechanisms of these interspecies interactions could inform therapeutic strategies for CDI.
Collapse
Affiliation(s)
- Alexander B. Smith
- Division of Protective Immunity, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | | | - Katharine K. Hewlett
- Division of Protective Immunity, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Troy R. Scoggins
- Department of Chemistry, University of Florida, Gainesville, Florida, USA
| | - Montana Knight
- Department of Biomedical and Health Informatics, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Abigail M. Lustig
- Division of Infectious Diseases, Department of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Yanhong Li
- Division of Infectious Diseases, Department of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
- Tsinghua University School of Medicine, Beijing, China
| | - Kirsten M. Evans
- Division of Infectious Diseases, Department of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Yingchan Guo
- Department of Chemistry, University of Florida, Gainesville, Florida, USA
| | - Qianxuan She
- Division of Protective Immunity, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
- Department of Pediatrics, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | | | - Timothy J. Garrett
- Department of Chemistry, University of Florida, Gainesville, Florida, USA
- Department of Pathology, Immunology, and Laboratory Medicine, University of Florida, Gainesville, Florida, USA
| | - Ahmed M. Moustafa
- Department of Pediatrics, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Daria Van Tyne
- Division of Infectious Diseases, Department of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Boone M. Prentice
- Department of Chemistry, University of Florida, Gainesville, Florida, USA
| | - Joseph P. Zackular
- Division of Protective Immunity, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
- Department of Pathology and Laboratory Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Institute for Immunology and Immune Health, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
8
|
Bonney JR, Kang WY, Specker JT, Liang Z, Scoggins TR, Prentice BM. Relative Quantification of Lipid Isomers in Imaging Mass Spectrometry Using Gas-Phase Charge Inversion Ion/Ion Reactions and Infrared Multiphoton Dissociation. Anal Chem 2023; 95:17766-17775. [PMID: 37991720 DOI: 10.1021/acs.analchem.3c03804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
Accurate structural identification of lipids in imaging mass spectrometry is critical to properly contextualizing spatial distributions with tissue biochemistry. Gas-phase charge inversion ion/ion reactions alter the ion type prior to dissociation to allow for more structurally informative fragmentation and improve lipid identification at the isomeric level. In this work, infrared multiphoton dissociation (IRMPD) was interfaced with a commercial hybrid Qh-FT-ICR mass spectrometer to enable the rapid fragmentation of gas-phase charge inversion ion/ion reaction products at every pixel in imaging mass spectrometry experiments. An ion/ion reaction between phosphatidylcholine (PC) monocations generated from rat brain tissue via matrix-assisted laser desorption/ionization (MALDI) and 1,4-phenylenediproprionic acid reagent dianions generated via electrospray ionization (ESI) followed by IRMPD of the resulting product ion complex produces selective fatty acyl chain cleavages indicative of fatty acyl carbon compositions in the lipid. Ion/ion reaction images using this workflow allow for mapping of the relative spatial distribution of multiple PC isomers under a single sum composition lipid identification. Lipid isomers display significantly different relative spatial distributions within rat brain tissue, highlighting the importance of resolving isomers in imaging mass spectrometry experiments.
Collapse
Affiliation(s)
- Julia R Bonney
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| | - Woo-Young Kang
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| | - Jonathan T Specker
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| | - Zhongling Liang
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| | - Troy R Scoggins
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| | - Boone M Prentice
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| |
Collapse
|
9
|
Yan T, Liang Z, Prentice BM. Imaging and Structural Characterization of Phosphatidylcholine Isomers from Rat Brain Tissue Using Sequential Collision-Induced Dissociation/Electron-Induced Dissociation. Anal Chem 2023; 95:15707-15715. [PMID: 37818979 PMCID: PMC10639000 DOI: 10.1021/acs.analchem.3c03077] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2023]
Abstract
The chemical complexity of biological tissues creates challenges in the analysis of lipids via imaging mass spectrometry. The presence of isobaric and isomeric compounds introduces chemical noise that makes it difficult to unambiguously identify and accurately map the spatial distributions of these compounds. Electron-induced dissociation (EID) has previously been shown to profile phosphatidylcholine (PCs) sn-isomers directly from rat brain tissue in matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry. However, the acquisition of true pixel-by-pixel images, as opposed to regional profiling measurements, using EID is difficult due to low fragmentation efficiency and precursor ion signal dilution into multiple fragment ion channels, resulting in low sensitivity. In this work, we have developed a sequential collision-induced dissociation (CID)/EID method to visualize the distribution of sn-isomers in MALDI imaging mass spectrometry experiments. Briefly, CID is performed on sodium-adducted PCs, which results in facile loss of the phosphocholine headgroup. This ion is then subjected to an EID analysis. Since the lipid headgroup is removed prior to EID, a major fragmentation pathway common to EID ion activation is eliminated, resulting in a more sensitive analysis. This sequential CID/EID workflow generates sn-specific fragment ions allowing for the assignment of the sn-positions. Carbon-carbon double-bond (C═C) positions are also localized along the fatty acyl tails by the presence of a 2 Da shift pattern in the fragment ions arising from carbon-carbon bond cleavages. Moreover, the integration of the CID/EID method into MALDI imaging mass spectrometry enables the mapping of the absolute and relative distribution of sn-isomers at every pixel. The localized relative abundances of sn-isomers vary throughout brain substructures and likely reflect different biological functions and metabolism.
Collapse
Affiliation(s)
- Tingting Yan
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| | - Zhongling Liang
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| | - Boone M. Prentice
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| |
Collapse
|
10
|
Specker JT, Prentice BM. Separation of Isobaric Lipids in Imaging Mass Spectrometry Using Gas-Phase Charge Inversion Ion/Ion Reactions. J Am Soc Mass Spectrom 2023; 34:1868-1878. [PMID: 37276072 PMCID: PMC10641901 DOI: 10.1021/jasms.3c00081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The diverse array of chemical compounds present in tissue samples results in many isobaric (i.e., same nominal mass) compounds in imaging mass spectrometry experiments. Adequate separation and differentiation of these compounds is necessary to ensure accurate analyte identification and avoid composite images comprising multiple compounds. High-resolution accurate mass (HRAM) measurements are able to resolve these compounds in some instances, but HRAM measurements are not always feasible depending on the instrument platform and the desired experimental time scale. Alternatively, tandem mass spectrometry (MS/MS) can be used to perform gas-phase transformations that improve molecular specificity. While conventional MS/MS methods employ collision induced dissociation (CID) to fragment compounds of interest and then analyze the product masses, gas-phase ion/ion reactions can be used to instead selectively react with desired classes of analytes. Herein, we have used gas-phase charge inversion ion/ion reactions to selectively resolve phosphatidylcholines (PCs) in isobaric lipid mixtures. A 1,4-phenylenedipropionic acid (PDPA) reagent dianion readily reacts with [M + H]+, [M + Na]+, and [M + K]+ ion types to produce demethylated product anions for each PC, [PC - CH3]-. These product anions are no longer isobaric and now differ in mass by 22 Da (protonated versus sodiated) and 16 Da (sodiated versus potassiated), respectively. This reaction has been used to differentiate isobaric lipids in the imaging mass spectrometry analysis of rat brain tissue.
Collapse
Affiliation(s)
| | - Boone M. Prentice
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| |
Collapse
|
11
|
Ellin NR, Miranda-Quintana RA, Prentice BM. Extended Similarity Methods for Efficient Data Mining in Imaging Mass Spectrometry. bioRxiv 2023:2023.07.27.550838. [PMID: 37546817 PMCID: PMC10402165 DOI: 10.1101/2023.07.27.550838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
Imaging mass spectrometry is a label-free imaging modality that allows for the spatial mapping of many compounds directly in tissues. In an imaging mass spectrometry experiment, a raster of the tissue surface produces a mass spectrum at each sampled x , y position, resulting in thousands of individual mass spectra, each comprising a pixel in the resulting ion images. However, efficient analysis of imaging mass spectrometry datasets can be challenging due to the hyperspectral characteristics of the data. Each spectrum contains several thousand unique compounds at discrete m/z values that result in unique ion images, which demands robust and efficient algorithms for searching, statistical analysis, and visualization. Some traditional post-processing techniques are fundamentally ill-equipped to dissect these types of data. For example, while principal component analysis (PCA) has long served as a useful tool for mining imaging mass spectrometry datasets to identify correlated analytes and biological regions of interest, the interpretation of the PCA scores and loadings can be non-trivial. The loadings often containing negative peaks in the PCA-derived pseudo-spectra, which are difficult to ascribe to underlying tissue biology. Herein, we have utilized extended similarity indices to streamline the interpretation of imaging mass spectrometry data. This novel workflow uses PCA as a pixel-selection method to parse out the most and least correlated pixels, which are then compared using the extended similarity indices. The extended similarity indices complement PCA by removing all non-physical artifacts and streamlining the interpretation of large volumes of IMS spectra simultaneously. The linear complexity, O ( N ) , of these indices suggests that large imaging mass spectrometry datasets can be analyzed in a 1:1 scale of time and space with respect to the size of the input data. The extended similarity indices algorithmic workflow is exemplified here by identifying discrete biological regions of mouse brain tissue.
Collapse
Affiliation(s)
- Nicholas R Ellin
- Department of Chemistry, University of Florida, Gainesville, FL, 32611-7200; USA
| | - Ramón Alain Miranda-Quintana
- Department of Chemistry, University of Florida, Gainesville, FL, 32611-7200; USA
- Quantum Theory Project, University of Florida, Gainesville, FL, 32611-7200; USA
| | - Boone M Prentice
- Department of Chemistry, University of Florida, Gainesville, FL, 32611-7200; USA
| |
Collapse
|
12
|
Liang Z, Prentice BM. Quantification of pharmaceutical compounds in tissue and plasma samples using selective ion accumulation with multiple mass isolation windows. J Mass Spectrom 2023; 58:e4958. [PMID: 37431164 DOI: 10.1002/jms.4958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 05/13/2023] [Accepted: 06/09/2023] [Indexed: 07/12/2023]
Abstract
Quantification of pharmaceutical compounds using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is an alternative to traditional liquid chromatography (LC)-MS techniques. Benefits of MALDI-based approaches include rapid analysis times for liquid samples and imaging mass spectrometry capabilities for tissue samples. As in most quantification experiments, the use of internal standards can compensate for spot-to-spot and shot-to-shot variability associated with MALDI sampling. However, the lack of chromatographic separation in traditional MALDI analyses results in diminished peak capacity due to the chemical noise background, which can be detrimental to the dynamic range and limit of detection of these approaches. These issues can be mitigated by using a hybrid mass spectrometer equipped with a quadrupole mass filter (QMF) that can be used to fractionate ions based on their mass-to-charge ratios. When the masses of the analytes and internal standards are sufficiently disparate in mass, it can be beneficial to effect multiple narrow mass isolation windows using the QMF, as opposed to a single wide mass isolation window, to minimize chemical noise while allowing for internal standard normalization. Herein, we demonstrate a MALDI MS quantification workflow incorporating multiple sequential mass isolation windows enabled on a QMF, which divides the total number of MALDI laser shots into multiple segments (i.e., one segment for each mass isolation window). This approach is illustrated through the quantitative analysis of the pharmaceutical compound enalapril in human plasma samples as well as the simultaneous quantification of three pharmaceutical compounds (enalapril, ramipril, and verapamil). Results show a decrease in the limit of detection, relative standard deviations below 10%, and accuracy above 85% for drug quantification using multiple mass isolation windows. This approach has also been applied to the quantification of enalapril in brain tissue from a rat dosed in vitro. The average concentration of enalapril determined by imaging mass spectrometry is in agreement with the concentration determined by LC-MS, giving an accuracy of 104%.
Collapse
Affiliation(s)
- Zhongling Liang
- Department of Chemistry, University of Florida, Gainesville, Florida, USA
| | - Boone M Prentice
- Department of Chemistry, University of Florida, Gainesville, Florida, USA
| |
Collapse
|
13
|
Yan T, Born MEN, Prentice BM. Structural Elucidation and Relative Quantification of Sodium- and Potassium-Cationized Phosphatidylcholine Regioisomers Directly from Tissue Using Electron Induced Dissociation. Int J Mass Spectrom 2023; 485:116998. [PMID: 37601139 PMCID: PMC10438893 DOI: 10.1016/j.ijms.2022.116998] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/22/2023]
Abstract
Comprehensive structural characterization of phosphatidylcholines (PCs) is essential to understanding their biological functions and roles in metabolism. Electron induced dissociation (EID) of protonated PCs directly generated from biological tissues has previously been shown to provide in-depth structural information on the lipid headgroup, regiosiomerism of fatty acyl tails and double bond positions. Although phosphatidylcholine ions formed via alkali metal cationization (i.e., [M + Na]+ and [M + K]+) are commonly generated during matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry experiments, the gas-phase ion chemistry behavior of EID on sodium- and potassium-cationized phosphatidylcholine ion types has not been studied for ions generated directly from tissue. Herein, we demonstrate EID on [M + Na]+ and [M + K]+ ion types in a MALDI imaging mass spectrometry workflow for lipid structural characterization. Briefly, near-complete structural information can be obtained upon EID of sodium- and potassium-cationized PCs, including diagnostic fragmentation of the lipid headgroup as well as identification of fatty acyl chain positions and double bond position. EID of cationized lipids generates sn-specific glycerol backbone cleavages as well as a favorable combined loss of sn-2 fatty acid with choline over sn-1, allowing for facile differentiation and relative quantification of PC regioisomers. Moreover, relative quantification of sn-positional isomers from biological tissue reveals that the relative percentages of sodium- and potassium-cationized sn-positional isomers varies significantly in different regions of rat brain tissue.
Collapse
Affiliation(s)
- Tingting Yan
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| | | | - Boone M. Prentice
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| |
Collapse
|
14
|
Xi Y, Sohn AL, Joignant AN, Cologna SM, Prentice BM, Muddiman DC. SMART: A data reporting standard for mass spectrometry imaging. J Mass Spectrom 2023; 58:e4904. [PMID: 36740651 PMCID: PMC10078510 DOI: 10.1002/jms.4904] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/16/2023] [Accepted: 01/19/2023] [Indexed: 06/18/2023]
Abstract
Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among different research groups and between techniques. The lack of consistency in data reporting inherently creates additional challenges in comparing intra- and inter-laboratory MSI data. In this tutorial, we propose a unified data reporting system, SMART, based on the common features shared between techniques. While there are limitations to any reporting system, SMART was decided upon after significant discussion to more easily understand and benchmark MSI data. SMART is not intended to be comprehensive but rather capture essential baseline information for a given MSI study; this could be within a study (e.g., effect of spot size on the measured ion signals) or between two studies (e.g., different MSI platform technologies applied to the same tissue type). This tutorial does not attempt to address the confidence with which annotations are made nor does it deny the importance of other parameters that are not included in the current SMART format. Ultimately, the goal of this tutorial is to discuss the necessity of establishing a uniform reporting system to communicate MSI data in publications and presentations in a simple format to readily interpret the parameters and baseline outcomes of the data.
Collapse
Affiliation(s)
- Ying Xi
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation CenterNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Alexandria L. Sohn
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Alena N. Joignant
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | | | | | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation CenterNorth Carolina State UniversityRaleighNorth CarolinaUSA
| |
Collapse
|
15
|
Specker JT, Smith AB, Keenan O, Zackular JP, Prentice BM. Investigation of Microbial Cooperation <em>via</em> Imaging Mass Spectrometry Analysis of Bacterial Colonies Grown on Agar and in Tissue During Infection. J Vis Exp 2022. [DOI: 10.3791/64200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
16
|
Prentice BM. Gas-Phase Ion-Ion Reactions for Lipid Identification in Biological Tissue Sections. Methods Mol Biol 2022; 2437:3-19. [PMID: 34902137 PMCID: PMC9148664 DOI: 10.1007/978-1-0716-2030-4_1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
The unambiguous identification of isobaric (i.e., same nominal mass) and isomeric (i.e., same exact mass) lipids remains a challenging yet vital aspect of imaging mass spectrometry (IMS) workflows. This chapter presents a methodology for the preparation of biological tissue samples and the use of a hybrid mass spectrometer to perform gas-phase charge inversion ion/ion reactions for improved lipid identification. This gas-phase ion/ion reaction method provides lipid structural information beyond what can be obtained via conventional tandem mass spectrometry (MS/MS) experiments. While this procedure is described here for the identification of phosphatidylcholine (PC) analyte cations using 1,4-phenylenedipropionic acid reagent dianions, it can readily be generalized to perform a diverse array of ion/ion reaction chemistries.
Collapse
Affiliation(s)
- Boone M. Prentice
- Department of Chemistry, University of Florida, Gainesville, FL 32611,Address correspondence to: Dr. Boone M. Prentice, 214 Leigh Hall, Department of Chemistry, University of Florida, Gainesville, FL 32611-7320, Phone: (352) 392-0556, Fax: (352) 392-4651,
| |
Collapse
|
17
|
Abstract
Lipids and metabolites are of interest in many clinical and research settings because it is the metabolome that is increasingly recognized as a more dynamic and sensitive molecular measure of phenotype. The enormous diversity of lipid structures and the importance of biological structure-function relationships in a wide variety of applications makes accurate identification a challenging yet crucial area of research in the lipid community. Indeed, subtle differences in the chemical structures of lipids can have important implications in cellular metabolism and many disease pathologies. The speed, sensitivity, and molecular specificity afforded by modern mass spectrometry has led to its widespread adoption in the field of lipidomics on many different instrument platforms and experimental workflows. However, unambiguous and complete structural identification of lipids by mass spectrometry remains challenging. Increasingly sophisticated tandem mass spectrometry (MS/MS) approaches are now being developed and seamlessly integrated into lipidomics workflows to meet this challenge. These approaches generally either (i) alter the type of ion that is interrogated or (ii) alter the dissociation method in order to improve the structural information obtained from the MS/MS experiment. In this Perspective, we highlight recent advances in both ion type alteration and ion dissociation methods for lipid identification by mass spectrometry. This discussion is aimed to engage investigators involved in fundamental ion chemistry and technology developments as well as practitioners of lipidomics and its many applications. The rapid rate of technology development in recent years has accelerated and strengthened the ties between these two research communities. We identify the common characteristics and practical figures of merit of these emerging approaches and discuss ways these may catalyze future directions of lipid structural elucidation research.
Collapse
Affiliation(s)
- Julia R Bonney
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| | - Boone M Prentice
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| |
Collapse
|
18
|
Manzo T, Prentice BM, Anderson KG, Raman A, Schalck A, Codreanu GS, Nava Lauson CB, Tiberti S, Raimondi A, Jones MA, Reyzer M, Bates BM, Spraggins JM, Patterson NH, McLean JA, Rai K, Tacchetti C, Tucci S, Wargo JA, Rodighiero S, Clise-Dwyer K, Sherrod SD, Kim M, Navin NE, Caprioli RM, Greenberg PD, Draetta G, Nezi L. Accumulation of long-chain fatty acids in the tumor microenvironment drives dysfunction in intrapancreatic CD8+ T cells. J Exp Med 2021; 217:151833. [PMID: 32491160 PMCID: PMC7398173 DOI: 10.1084/jem.20191920] [Citation(s) in RCA: 136] [Impact Index Per Article: 45.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Revised: 01/14/2020] [Accepted: 03/19/2020] [Indexed: 12/13/2022] Open
Abstract
CD8+ T cells are master effectors of antitumor immunity, and their presence at tumor sites correlates with favorable outcomes. However, metabolic constraints imposed by the tumor microenvironment (TME) can dampen their ability to control tumor progression. We describe lipid accumulation in the TME areas of pancreatic ductal adenocarcinoma (PDA) populated by CD8+ T cells infiltrating both murine and human tumors. In this lipid-rich but otherwise nutrient-poor TME, access to using lipid metabolism becomes particularly valuable for sustaining cell functions. Here, we found that intrapancreatic CD8+ T cells progressively accumulate specific long-chain fatty acids (LCFAs), which, rather than provide a fuel source, impair their mitochondrial function and trigger major transcriptional reprogramming of pathways involved in lipid metabolism, with the subsequent reduction of fatty acid catabolism. In particular, intrapancreatic CD8+ T cells specifically exhibit down-regulation of the very-long-chain acyl-CoA dehydrogenase (VLCAD) enzyme, which exacerbates accumulation of LCFAs and very-long-chain fatty acids (VLCFAs) that mediate lipotoxicity. Metabolic reprogramming of tumor-specific T cells through enforced expression of ACADVL enabled enhanced intratumoral T cell survival and persistence in an engineered mouse model of PDA, overcoming one of the major hurdles to immunotherapy for PDA.
Collapse
Affiliation(s)
- Teresa Manzo
- Department of Experimental Oncology, IRCCS European Institute of Oncology, Milano, Italy.,Department of Genomic Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Boone M Prentice
- Department of Biochemistry, Mass Spectrometry Research Center, Department of Chemistry, Department of Pharmacology and Medicine, Vanderbilt University, Nashville, TN
| | - Kristin G Anderson
- Clinical Research Division and Program in Immunology, Fred Hutchinson Cancer Research Center, Seattle, WA.,Departments of Medicine/Oncology and Immunology, University of Washington School of Medicine, Seattle, WA
| | - Ayush Raman
- Department of Genomic Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Aislyn Schalck
- Department of Genetics and Department of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | | | - Carina B Nava Lauson
- Department of Experimental Oncology, IRCCS European Institute of Oncology, Milano, Italy
| | - Silvia Tiberti
- Department of Experimental Oncology, IRCCS European Institute of Oncology, Milano, Italy
| | - Andrea Raimondi
- Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, San Raffaele Vita-Salute University, Milano, Italy
| | - Marissa A Jones
- Department of Biochemistry, Mass Spectrometry Research Center, Department of Chemistry, Department of Pharmacology and Medicine, Vanderbilt University, Nashville, TN
| | - Michelle Reyzer
- Department of Biochemistry, Mass Spectrometry Research Center, Department of Chemistry, Department of Pharmacology and Medicine, Vanderbilt University, Nashville, TN
| | - Breanna M Bates
- Clinical Research Division and Program in Immunology, Fred Hutchinson Cancer Research Center, Seattle, WA.,Departments of Medicine/Oncology and Immunology, University of Washington School of Medicine, Seattle, WA
| | - Jeffrey M Spraggins
- Department of Biochemistry, Mass Spectrometry Research Center, Department of Chemistry, Department of Pharmacology and Medicine, Vanderbilt University, Nashville, TN
| | - Nathan H Patterson
- Department of Biochemistry, Mass Spectrometry Research Center, Department of Chemistry, Department of Pharmacology and Medicine, Vanderbilt University, Nashville, TN
| | - John A McLean
- Center for Innovative Technology, Vanderbilt University, Nashville, TN
| | - Kunal Rai
- Department of Genomic Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Carlo Tacchetti
- Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, San Raffaele Vita-Salute University, Milano, Italy
| | - Sara Tucci
- Laboratory of Clinical Biochemistry and Metabolism Center for Pediatrics and Adolescent Medicine, University of Freiburg, Freiburg, Germany
| | - Jennifer A Wargo
- Department of Genomic Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX.,Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Simona Rodighiero
- Department of Experimental Oncology, IRCCS European Institute of Oncology, Milano, Italy
| | - Karen Clise-Dwyer
- Department of Stem Cell Transplantation, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Stacy D Sherrod
- Center for Innovative Technology, Vanderbilt University, Nashville, TN
| | - Michael Kim
- Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Nicholas E Navin
- Department of Genetics and Department of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Richard M Caprioli
- Department of Biochemistry, Mass Spectrometry Research Center, Department of Chemistry, Department of Pharmacology and Medicine, Vanderbilt University, Nashville, TN
| | - Philip D Greenberg
- Clinical Research Division and Program in Immunology, Fred Hutchinson Cancer Research Center, Seattle, WA.,Departments of Medicine/Oncology and Immunology, University of Washington School of Medicine, Seattle, WA
| | - Giulio Draetta
- Department of Genomic Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Luigi Nezi
- Department of Experimental Oncology, IRCCS European Institute of Oncology, Milano, Italy.,Department of Genomic Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
19
|
Fernández-Vega A, Chicano-Gálvez E, Prentice BM, Anderson D, Priego-Capote F, López-Bascón MA, Calderón-Santiago M, Avendaño MS, Guzmán-Ruiz R, Tena-Sempere M, Fernández JA, Caprioli RM, Malagón MM. Optimization of a MALDI-Imaging protocol for studying adipose tissue-associated disorders. Talanta 2020; 219:121184. [PMID: 32887102 DOI: 10.1016/j.talanta.2020.121184] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 05/13/2020] [Accepted: 05/15/2020] [Indexed: 12/13/2022]
Abstract
Matrix-assisted laser desorption ionization (MALDI) imaging mass spectrometry (IMS) is increasingly recognized for its potential in the discovery of novel biomarkers directly from tissue sections. However, there are no MALDI IMS studies as yet on the adipose tissue, a lipid-enriched tissue that plays a pivotal role in the development of obesity-associated disorders. Herein, we aimed at developing an optimized method for analyzing adipose tissue lipid composition under both physiological and pathological conditions by MALDI IMS. Our studies showed an exacerbated lipid delocalization from adipose tissue sections when conventional strategies were applied. However, our optimized method using conductive-tape sampling and 2,5-dihydroxybenzoic acid (DHB) as a matrix, preserved the anatomical organization and minimized lipid diffusion from sample sections. This method enabled the identification of a total of 625 down-regulated and 328 up-regulated m/z values in the adipose tissue from a rat model of extreme obesity as compared to lean animals. Combination of MALDI IMS and liquid chromatography (LC)-MS/MS data identified 44 differentially expressed lipid species between lean and obese animals, including phospholipids and sphingomyelins. Among the lipids identified, SM(d18:0_18:2), PE(P-16:0_20:0), and PC(O-16:0_16:1) showed a differential spatial distribution in the adipose tissue of lean vs. obese animals. In sum, our method provides a valuable new tool for research on adipose tissue that may pave the way for the identification of novel biomarkers of obesity and metabolic disease.
Collapse
Affiliation(s)
- A Fernández-Vega
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain
| | | | - B M Prentice
- Department of Chemistry, University of Florida, Gainesville, FL, USA
| | - D Anderson
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN, 37232, USA; Department of Biochemistry, Vanderbilt University, Nashville, TN, 37232, USA
| | - F Priego-Capote
- Department of Analytical Chemistry, IMIBIC/UCO/HURS, Cordoba, Spain
| | - M A López-Bascón
- Department of Analytical Chemistry, IMIBIC/UCO/HURS, Cordoba, Spain
| | | | - M S Avendaño
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain
| | - R Guzmán-Ruiz
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain
| | - M Tena-Sempere
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain
| | - J A Fernández
- Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940, Leioa, Spain
| | - R M Caprioli
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN, 37232, USA; Department of Biochemistry, Vanderbilt University, Nashville, TN, 37232, USA; Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940, Leioa, Spain; Department of Chemistry, Vanderbilt University, Nashville, TN, 37232, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, 37232, USA; Department of Pharmacology, Vanderbilt University, Nashville, TN, 37232, USA; Department of Medicine, Vanderbilt University, Nashville, TN, 37232, USA
| | - M M Malagón
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain.
| |
Collapse
|
20
|
Prentice BM, Ryan DJ, Grove KJ, Cornett DS, Caprioli RM, Spraggins JM. Dynamic Range Expansion by Gas-Phase Ion Fractionation and Enrichment for Imaging Mass Spectrometry. Anal Chem 2020; 92:13092-13100. [PMID: 32845133 PMCID: PMC8340028 DOI: 10.1021/acs.analchem.0c02121] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
In the analysis of biological tissue by imaging mass spectrometry (IMS), the limit of detection and dynamic range are of paramount importance in obtaining experimental results that provide insight into underlying biological processes. Many important biomolecules are present in the tissue milieu in low concentrations and in complex mixtures with other compounds of widely ranging abundances, challenging the limits of analytical technologies. In many IMS experiments, the ion signal can be dominated by a few highly abundant ion species. On trap-based instrument platforms that accumulate ions prior to mass analysis, these high abundance ions can diminish the detection and dynamic range of lower abundance ions. Herein, we describe two strategies for combating these challenges during IMS experiments on a hybrid QhFT-ICR MS. In one iteration, the mass resolving capabilities of a quadrupole mass filter are used to selectively enrich ions of interest via a technique previously termed continuous accumulation of selected ions. Second, we have introduced a supplemental dipolar AC waveform to the quadrupole mass filter of a commercial QhFT-ICR mass spectrometer to perform selected ion ejection prior to the ion accumulation region. This setup allows the selective ejection of the most abundant ion species prior to ion accumulation, thereby greatly improving the molecular depth with which IMS can probe tissue samples. The gain in sensitivity of both of these approaches roughly scales with the number of accumulated laser shots up to the charge capacity of the ion accumulation cell. The efficiencies of these two strategies are described here by performing lipid imaging mass spectrometry analyses of a rat brain.
Collapse
Affiliation(s)
- Boone M Prentice
- Department of Biochemistry, Vanderbilt University, Nashville, Tennessee 37232, United States
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37232, United States
| | - Daniel J Ryan
- ExxonMobil Research and Engineering Company, Annandale, New Jersey 08801, United States
| | - Kerri J Grove
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37232, United States
- Department of Chemistry, Vanderbilt University, Nashville, Tennessee 37232, United States
| | | | - Richard M Caprioli
- Department of Biochemistry, Vanderbilt University, Nashville, Tennessee 37232, United States
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37232, United States
- Department of Chemistry, Vanderbilt University, Nashville, Tennessee 37232, United States
- Department of Pharmacology and Medicine, Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
| | - Jeffrey M Spraggins
- Department of Biochemistry, Vanderbilt University, Nashville, Tennessee 37232, United States
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37232, United States
- Department of Chemistry, Vanderbilt University, Nashville, Tennessee 37232, United States
| |
Collapse
|
21
|
Specker JT, Van Orden SL, Ridgeway ME, Prentice BM. Identification of Phosphatidylcholine Isomers in Imaging Mass Spectrometry Using Gas-Phase Charge Inversion Ion/Ion Reactions. Anal Chem 2020; 92:13192-13201. [PMID: 32845134 DOI: 10.1021/acs.analchem.0c02350] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Gas-phase ion/ion reactions have been enabled on a commercial dual source, hybrid QhFT-ICR mass spectrometer for use during imaging mass spectrometry experiments. These reactions allow for the transformation of the ion type most readily generated from the tissue surface to an ion type that gives improved chemical structural information upon tandem mass spectrometry (MS/MS) without manipulating the tissue sample. This process is demonstrated via the charge inversion reaction of phosphatidylcholine (PC) lipid cations generated from rat brain tissue via matrix-assisted laser desorption/ionization (MALDI) with 1,4-phenylenedipropionic acid (PDPA) reagent dianions generated via electrospray ionization (ESI). Collision-induced dissociation (CID) of the resulting demethylated PC product anions allows for the determination of the lipid fatty acyl tail identities and positions, which is not possible via CID of the precursor lipid cations. The abundance of lipid isomers revealed by this workflow is found to vary significantly in different regions of the brain. As each isoform may have a unique cellular function, these results underscore the importance of accurately separating and identifying the many isobaric and isomeric lipids and metabolites that can complicate image interpretation and spectral analysis.
Collapse
Affiliation(s)
- Jonathan T Specker
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| | | | - Mark E Ridgeway
- Bruker Daltonics, Billerica, Massachusetts 01821, United States
| | - Boone M Prentice
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
| |
Collapse
|
22
|
Perry WJ, Patterson NH, Prentice BM, Neumann EK, Caprioli RM, Spraggins JM. Uncovering matrix effects on lipid analyses in MALDI imaging mass spectrometry experiments. J Mass Spectrom 2020; 55:e4491. [PMID: 31860760 PMCID: PMC7383219 DOI: 10.1002/jms.4491] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 11/25/2019] [Accepted: 12/16/2019] [Indexed: 05/04/2023]
Abstract
The specific matrix used in matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) can have an effect on the molecules ionized from a tissue sample. The sensitivity for distinct classes of biomolecules can vary when employing different MALDI matrices. Here, we compare the intensities of various lipid subclasses measured by Fourier transform ion cyclotron resonance (FT-ICR) IMS of murine liver tissue when using 9-aminoacridine (9AA), 5-chloro-2-mercaptobenzothiazole (CMBT), 1,5-diaminonaphthalene (DAN), 2,5-Dihydroxyacetophenone (DHA), and 2,5-dihydroxybenzoic acid (DHB). Principal component analysis and receiver operating characteristic curve analysis revealed significant matrix effects on the relative signal intensities observed for different lipid subclasses and adducts. Comparison of spectral profiles and quantitative assessment of the number and intensity of species from each lipid subclass showed that each matrix produces unique lipid signals. In positive ion mode, matrix application methods played a role in the MALDI analysis for different cationic species. Comparisons of different methods for the application of DHA showed a significant increase in the intensity of sodiated and potassiated analytes when using an aerosol sprayer. In negative ion mode, lipid profiles generated using DAN were significantly different than all other matrices tested. This difference was found to be driven by modification of phosphatidylcholines during ionization that enables them to be detected in negative ion mode. These modified phosphatidylcholines are isomeric with common phosphatidylethanolamines confounding MALDI IMS analysis when using DAN. These results show an experimental basis of MALDI analyses when analyzing lipids from tissue and allow for more informed selection of MALDI matrices when performing lipid IMS experiments.
Collapse
Affiliation(s)
- William J. Perry
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN
- Department of Chemistry, Vanderbilt University, Nashville, TN
| | - Nathan Heath Patterson
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN
- Department of Biochemistry, Vanderbilt University, Nashville, TN
| | - Boone M. Prentice
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN
- Department of Biochemistry, Vanderbilt University, Nashville, TN
| | - Elizabeth K. Neumann
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN
- Department of Biochemistry, Vanderbilt University, Nashville, TN
| | - Richard M. Caprioli
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN
- Department of Chemistry, Vanderbilt University, Nashville, TN
- Department of Biochemistry, Vanderbilt University, Nashville, TN
- Department of Pharmacology, Vanderbilt University, Nashville, TN
- Department of Medicine, Vanderbilt University, Nashville, TN
| | - Jeffrey M. Spraggins
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN
- Department of Chemistry, Vanderbilt University, Nashville, TN
- Department of Biochemistry, Vanderbilt University, Nashville, TN
- Corresponding Author Address reprint requests to Jeffrey M. Spraggins, V9140 MRBIII, 465 21 Ave South, Nashville, TN 37232, (615) 343-7333,
| |
Collapse
|
23
|
Cassat JE, Moore JL, Wilson KJ, Stark Z, Prentice BM, Van de Plas R, Perry WJ, Zhang Y, Virostko J, Colvin DC, Rose KL, Judd AM, Reyzer ML, Spraggins JM, Grunenwald CM, Gore JC, Caprioli RM, Skaar EP. Integrated molecular imaging reveals tissue heterogeneity driving host-pathogen interactions. Sci Transl Med 2019. [PMID: 29540616 DOI: 10.1126/scitranslmed.aan6361] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Diseases are characterized by distinct changes in tissue molecular distribution. Molecular analysis of intact tissues traditionally requires preexisting knowledge of, and reagents for, the targets of interest. Conversely, label-free discovery of disease-associated tissue analytes requires destructive processing for downstream identification platforms. Tissue-based analyses therefore sacrifice discovery to gain spatial distribution of known targets or sacrifice tissue architecture for discovery of unknown targets. To overcome these obstacles, we developed a multimodality imaging platform for discovery-based molecular histology. We apply this platform to a model of disseminated infection triggered by the pathogen Staphylococcus aureus, leading to the discovery of infection-associated alterations in the distribution and abundance of proteins and elements in tissue in mice. These data provide an unbiased, three-dimensional analysis of how disease affects the molecular architecture of complex tissues, enable culture-free diagnosis of infection through imaging-based detection of bacterial and host analytes, and reveal molecular heterogeneity at the host-pathogen interface.
Collapse
Affiliation(s)
- James E Cassat
- Division of Pediatric Infectious Diseases, Department of Pediatrics, Vanderbilt University Medical Center, Nashville, TN 37232, USA.,Department of Pathology, Microbiology and Immunology, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - Jessica L Moore
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA.,Department of Chemistry, Vanderbilt University, Nashville, TN 37232, USA.,Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA
| | - Kevin J Wilson
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232, USA
| | - Zach Stark
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232, USA
| | - Boone M Prentice
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA.,Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA
| | - Raf Van de Plas
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA.,Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA.,Delft Center for Systems and Control, Delft University of Technology, Delft, Netherlands
| | - William J Perry
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA.,Department of Chemistry, Vanderbilt University, Nashville, TN 37232, USA
| | - Yaofang Zhang
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA.,Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA
| | - John Virostko
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232, USA
| | - Daniel C Colvin
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232, USA
| | - Kristie L Rose
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA.,Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA
| | - Audra M Judd
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA
| | - Michelle L Reyzer
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA
| | - Jeffrey M Spraggins
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA.,Department of Chemistry, Vanderbilt University, Nashville, TN 37232, USA.,Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA
| | - Caroline M Grunenwald
- Department of Pathology, Microbiology and Immunology, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - John C Gore
- Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA.,Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232, USA.,Departments of Radiology and Radiologic Sciences, Biomedical Engineering, Molecular Physiology and Biophysics, and Physics and Astronomy, Vanderbilt University, Nashville, TN 37232, USA
| | - Richard M Caprioli
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232, USA.,Department of Chemistry, Vanderbilt University, Nashville, TN 37232, USA.,Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA.,Department of Medicine, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - Eric P Skaar
- Department of Pathology, Microbiology and Immunology, Vanderbilt University Medical Center, Nashville, TN 37232, USA. .,U.S. Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, 37232, USA
| |
Collapse
|
24
|
Prentice BM, Hart NJ, Phillips N, Haliyur R, Judd A, Armandala R, Spraggins JM, Lowe CL, Boyd KL, Stein RW, Wright CV, Norris JL, Powers AC, Brissova M, Caprioli RM. Imaging mass spectrometry enables molecular profiling of mouse and human pancreatic tissue. Diabetologia 2019; 62:1036-1047. [PMID: 30955045 PMCID: PMC6553460 DOI: 10.1007/s00125-019-4855-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Accepted: 02/20/2019] [Indexed: 12/20/2022]
Abstract
AIMS/HYPOTHESIS The molecular response and function of pancreatic islet cells during metabolic stress is a complex process. The anatomical location and small size of pancreatic islets coupled with current methodological limitations have prevented the achievement of a complete, coherent picture of the role that lipids and proteins play in cellular processes under normal conditions and in diseased states. Herein, we describe the development of untargeted tissue imaging mass spectrometry (IMS) technologies for the study of in situ protein and, more specifically, lipid distributions in murine and human pancreases. METHODS We developed matrix-assisted laser desorption/ionisation (MALDI) IMS protocols to study metabolite, lipid and protein distributions in mouse (wild-type and ob/ob mouse models) and human pancreases. IMS allows for the facile discrimination of chemically similar lipid and metabolite isoforms that cannot be distinguished using standard immunohistochemical techniques. Co-registration of MS images with immunofluorescence images acquired from serial tissue sections allowed accurate cross-registration of cell types. By acquiring immunofluorescence images first, this serial section approach guides targeted high spatial resolution IMS analyses (down to 15 μm) of regions of interest and leads to reduced time requirements for data acquisition. RESULTS MALDI IMS enabled the molecular identification of specific phospholipid and glycolipid isoforms in pancreatic islets with intra-islet spatial resolution. This technology shows that subtle differences in the chemical structure of phospholipids can dramatically affect their distribution patterns and, presumably, cellular function within the islet and exocrine compartments of the pancreas (e.g. 18:1 vs 18:2 fatty acyl groups in phosphatidylcholine lipids). We also observed the localisation of specific GM3 ganglioside lipids [GM3(d34:1), GM3(d36:1), GM3(d38:1) and GM3(d40:1)] within murine islet cells that were correlated with a higher level of GM3 synthase as verified by immunostaining. However, in human pancreas, GM3 gangliosides were equally distributed in both the endocrine and exocrine tissue, with only one GM3 isoform showing islet-specific localisation. CONCLUSIONS/INTERPRETATION The development of more complete molecular profiles of pancreatic tissue will provide important insight into the molecular state of the pancreas during islet development, normal function, and diseased states. For example, this study demonstrates that these results can provide novel insight into the potential signalling mechanisms involving phospholipids and glycolipids that would be difficult to detect by targeted methods, and can help raise new hypotheses about the types of physiological control exerted on endocrine hormone-producing cells in islets. Importantly, the in situ measurements afforded by IMS do not require a priori knowledge of molecules of interest and are not susceptible to the limitations of immunohistochemistry, providing the opportunity for novel biomarker discovery. Notably, the presence of multiple GM3 isoforms in mouse islets and the differential localisation of lipids in human tissue underscore the important role these molecules play in regulating insulin modulation and suggest species, organ, and cell specificity. This approach demonstrates the importance of both high spatial resolution and high molecular specificity to accurately survey the molecular composition of complex, multi-functional tissues such as the pancreas.
Collapse
Affiliation(s)
- Boone M Prentice
- 9160 MRB III, Department of Biochemistry, Vanderbilt University, Nashville, TN, 37232, USA
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN, USA
| | - Nathaniel J Hart
- Division of Diabetes, Endocrinology and Metabolism, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Neil Phillips
- Division of Diabetes, Endocrinology and Metabolism, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Rachana Haliyur
- Department of Molecular Physiology and Biophysics, Vanderbilt University, Nashville, TN, USA
| | - Audra Judd
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN, USA
| | - Radhika Armandala
- Division of Diabetes, Endocrinology and Metabolism, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Jeffrey M Spraggins
- 9160 MRB III, Department of Biochemistry, Vanderbilt University, Nashville, TN, 37232, USA
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN, USA
- Department of Chemistry, Vanderbilt University, Nashville, TN, USA
| | - Cindy L Lowe
- Translational Pathology Shared Resource, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Kelli L Boyd
- Translational Pathology Shared Resource, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Roland W Stein
- Department of Molecular Physiology and Biophysics, Vanderbilt University, Nashville, TN, USA
| | - Christopher V Wright
- Department of Cell & Developmental Biology, Vanderbilt University, Nashville, TN, USA
| | - Jeremy L Norris
- 9160 MRB III, Department of Biochemistry, Vanderbilt University, Nashville, TN, 37232, USA
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN, USA
- Department of Chemistry, Vanderbilt University, Nashville, TN, USA
| | - Alvin C Powers
- Division of Diabetes, Endocrinology and Metabolism, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Molecular Physiology and Biophysics, Vanderbilt University, Nashville, TN, USA
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA
| | - Marcela Brissova
- Division of Diabetes, Endocrinology and Metabolism, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Richard M Caprioli
- 9160 MRB III, Department of Biochemistry, Vanderbilt University, Nashville, TN, 37232, USA.
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN, USA.
- Department of Chemistry, Vanderbilt University, Nashville, TN, USA.
- Department of Pharmacology and Medicine, Vanderbilt University, Nashville, TN, USA.
| |
Collapse
|
25
|
Prentice BM, McMillen JC, Caprioli RM. Multiple TOF/TOF Events in a Single Laser Shot for Multiplexed Lipid Identifications in MALDI Imaging Mass Spectrometry. Int J Mass Spectrom 2019; 437:30-37. [PMID: 30906202 PMCID: PMC6424509 DOI: 10.1016/j.ijms.2018.06.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Tandem mass spectrometry (MS/MS) is often used to identify lipids in matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) workflows. The molecular specificity afforded by MS/MS is crucial on MALDI time-of-flight (TOF) platforms that generally lack high resolution accurate mass measurement capabilities. Unfortunately, imaging MS/MS workflows generally only monitor a single precursor ion over the imaged area, limiting the throughput of this methodology. Herein, we demonstrate that multiple TOF/TOF events performed in each laser shot can be used to improve the throughput of imaging MS/MS. This is shown to enable the simultaneous identification of multiple phosphatidylcholine lipids in rat brain tissue. Uniquely, the separation in time achieved for the precursor ions in the TOF-1 region of the instrument is maintained for the fragment ions as they are analyzed in TOF-2, allowing for the differentiation of fragment ions of the exact same m/z derived from different precursor ions (e.g., the m/z 163 fragment ion from precursor ion m/z 772.5 is easily distinguished from the m/z 163 fragment ion from precursor ion m/z 826.5). This multiplexed imaging MS/MS approach allows for the acquisition of complete fragment ion spectra for multiple precursor ions per laser shot.
Collapse
Affiliation(s)
- Boone M. Prentice
- Department of Biochemistry, Vanderbilt University, Nashville, TN 37232
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232
| | - Josiah C. McMillen
- Department of Chemistry, Vanderbilt University, Nashville, TN 37232
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232
| | - Richard M. Caprioli
- Department of Biochemistry, Vanderbilt University, Nashville, TN 37232
- Department of Chemistry, Vanderbilt University, Nashville, TN 37232
- Departments of Pharmacology and Medicine, Vanderbilt University, Nashville, TN 37232
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN 37232
- Address correspondence to: Dr. R. M. Caprioli, 9160 MRB III, Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA, Phone: (615)322-4336, Fax: (615) 343-8372,
| |
Collapse
|
26
|
Prentice BM, Ryan DJ, Van de Plas R, Caprioli RM, Spraggins JM. Enhanced Ion Transmission Efficiency up to m/ z 24 000 for MALDI Protein Imaging Mass Spectrometry. Anal Chem 2018; 90:5090-5099. [PMID: 29444410 PMCID: PMC6905630 DOI: 10.1021/acs.analchem.7b05105] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
The molecular identification of species of interest is an important part of an imaging mass spectrometry (IMS) experiment. The high resolution accurate mass capabilities of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) have recently been shown to facilitate the identification of proteins in matrix-assisted laser desorption/ionization (MALDI) IMS. However, these experiments are typically limited to proteins giving rise to ions of relatively low m/ z due to difficulties transmitting and measuring large molecular weight ions of low charge states. Herein we have modified the source gas manifold of a commercial MALDI FT-ICR MS to regulate the gas flow and pressure to maximize the transmission of large m/ z protein ions through the ion funnel region of the instrument. By minimizing the contribution of off-axis gas disruption to ion focusing and maximizing the effective potential wall confining the ions through pressure optimization, the signal-to-noise ratios (S/N) of most protein species were improved by roughly 1 order of magnitude compared to normal source conditions. These modifications enabled the detection of protein standards up to m/ z 24 000 and the detection of proteins from tissue up to m/ z 22 000 with good S/N, roughly doubling the mass range for which high quality protein ion images from rat brain and kidney tissue could be produced. Due to the long time-domain transients (>4 s) required to isotopically resolve high m/ z proteins, we have used these data as part of an FT-ICR IMS-microscopy data-driven image fusion workflow to produce estimated protein images with both high mass and high spatial resolutions.
Collapse
Affiliation(s)
- Boone M. Prentice
- Department of Biochemistry, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
- Mass Spectrometry Research Center, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
| | - Daniel J. Ryan
- Department of Chemistry, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
| | - Raf Van de Plas
- Mass Spectrometry Research Center, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
- Delft Center for Systems and Control, Delft University of Technology, Delft 2628 CD, The Netherlands
| | - Richard M. Caprioli
- Department of Biochemistry, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
- Mass Spectrometry Research Center, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
- Department of Chemistry, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
- Department of Pharmacology and Medicine, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
| | - Jeffrey M. Spraggins
- Department of Biochemistry, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
- Mass Spectrometry Research Center, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
- Department of Chemistry, Vanderbilt University and Vanderbilt University Medical Center, Nashville, Tennessee 37232, United States
| |
Collapse
|
27
|
Ryan DJ, Nei D, Prentice BM, Rose KL, Caprioli RM, Spraggins JM. Protein identification in imaging mass spectrometry through spatially targeted liquid micro-extractions. Rapid Commun Mass Spectrom 2018; 32:442-450. [PMID: 29226434 PMCID: PMC5812809 DOI: 10.1002/rcm.8042] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 10/16/2017] [Accepted: 11/22/2017] [Indexed: 05/02/2023]
Abstract
RATIONALE Liquid extraction surface analysis (LESA) can be used to generate spatially directed protein identifications in an imaging mass spectrometry (IMS) workflow. This approach involves the use of robotic micro-extractions coupled to online liquid chromatography (LC). We have characterized the extraction efficiency of this method as well as its ability to identify proteins from a matrix assisted laser/desorption ionization (MALDI) IMS experiment. METHODS Proteins and peptides were extracted from transverse sections of a rat brain and sagittal sections of a mouse pup using liquid surface extractions. Extracts were either analyzed by online LC coupled to a high mass resolution Fourier transform ion cyclotron resonance (FTICR) mass spectrometer or collected offline and analyzed by traditional LC/MS methods. Identifications were made using both top-down and bottom-up methodologies. MALDI images were acquired on a 15T FTICR mass spectrometer at 125 μm spatial resolution. RESULTS Robotic liquid surface extractions are reproducible across various tissue types, providing significantly improved spatial resolution, with respect to extractions, while still allowing for a robust number of protein identifications. A single 2-μL extract can provide identification of over 14,000 peptides with little sample preparation, increasing throughput for spatially targeted workflows. Surface extractions from tissue were coupled directly to LC to gather spatially relevant proteomics data. CONCLUSIONS Robotic liquid surface extractions can be used to interrogate discrete regions of tissue to provide protein identifications with high throughput, accuracy, and robustness. The direct coupling of tissue surface extractions and LC offers a new and effective approach to provide spatial proteomics data in an imaging experiment.
Collapse
Affiliation(s)
- Daniel J Ryan
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, TN, 37235, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, TN, 37235, USA
| | - David Nei
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, TN, 37235, USA
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN, 37205, USA
| | - Boone M Prentice
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, TN, 37235, USA
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN, 37205, USA
| | - Kristie L Rose
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, TN, 37235, USA
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN, 37205, USA
| | - Richard M Caprioli
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, TN, 37235, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, TN, 37235, USA
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN, 37205, USA
- Department of Pharmacology, Vanderbilt University, 442 Robinson Research Building, 2220 Pierce Avenue, Nashville, TN, 37232, USA
- Department of Medicine, Vanderbilt University, 465 21st Ave S #9160, Nashville, TN, 37235, USA
| | - Jeffrey M Spraggins
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, TN, 37235, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, TN, 37235, USA
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN, 37205, USA
| |
Collapse
|
28
|
Abstract
In this review, we will highlight technologies that enable scientists to study the molecular characteristics of tissues and/or cells without the need for antibodies or other labeling techniques. Specifically, we will focus on matrix-assisted laser desorption/ionization imaging mass spectrometry, infrared spectroscopy, and Raman spectroscopy.
Collapse
Affiliation(s)
- Boone M Prentice
- Department of Biochemistry, Vanderbilt University, Nashville, Tennessee, USA; Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee, USA
| | - Richard M Caprioli
- Department of Biochemistry, Vanderbilt University, Nashville, Tennessee, USA; Department of Chemistry, Vanderbilt University, Nashville, Tennessee, USA; Departments of Pharmacology and Medicine, Vanderbilt University, Nashville, Tennessee, USA; Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee, USA.
| | - Vincent Vuiblet
- Biophotonic Laboratory, UMR CNRS 7369 URCA, Reims, France; Nephropathology, Department of Biopathology Laboratory, CHU de Reims, Reims, France; Nephrology and Renal Transplantation department, CHU de Reims, Reims, France.
| |
Collapse
|
29
|
Jarrell TM, Owen BC, Riedeman JS, Prentice BM, Pulliam CJ, Max J, Kenttämaa HI. Laser-Induced Acoustic Desorption/Electron Ionization of Amino Acids and Small Peptides. J Am Soc Mass Spectrom 2017; 28:1091-1098. [PMID: 28500583 DOI: 10.1007/s13361-017-1684-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Revised: 04/05/2017] [Accepted: 04/07/2017] [Indexed: 06/07/2023]
Abstract
Laser-induced acoustic desorption (LIAD) allows for desorption of neutral nonvolatile compounds independent of their volatility or thermal stability. Many different ionization methods have been coupled with LIAD. Hence, this setup provides a better control over the types of ions formed than other mass spectrometry evaporation/ionization methods commonly used to characterize biomolecules, such as ESI or MALDI. In this study, the utility of LIAD coupled with electron ionization (EI) was tested for the analysis of common amino acids with no derivatization. The results compared favorably with previously reported EI mass spectra obtained using thermal desorption/EI. Further, LIAD/EI mass spectra collected for hydrochloride salts of two amino acids were found to be similar to those measured for the neutral amino acids with the exception of the appearance of an HCl+● ion. However, the hydrochloride salt of arginine showed a distinctly different LIAD/EI mass spectrum than the previously published literature EI mass spectrum, likely due to its highly basic side chain that makes a specific zwitterionic form particularly favorable. Finally, EI mass spectra were measured for seven small peptides, including di-, tri-, and tetrapeptides. These mass spectra show a variety of ion types. However, an type ions are prevalent. Also, electron-induced dissociation (EID) of protonated peptides has been reported to form primarily an type ions. In addition, the loss of small neutral molecules and side-chain cleavages were observed that are reminiscent of other high-energy fragmentation methods, such as EID. Finally, the isomeric dipeptides LG and IG were found to produce drastically different EI mass spectra, thus allowing differentiation of the leucine and isoleucine amino acids in these dipeptides. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Tiffany M Jarrell
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Benjamin C Owen
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - James S Riedeman
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Boone M Prentice
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Chris J Pulliam
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Joann Max
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - Hilkka I Kenttämaa
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA.
| |
Collapse
|
30
|
Rizzo DG, Prentice BM, Moore JL, Norris JL, Caprioli RM. Enhanced Spatially Resolved Proteomics Using On-Tissue Hydrogel-Mediated Protein Digestion. Anal Chem 2017; 89:2948-2955. [DOI: 10.1021/acs.analchem.6b04395] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- David G. Rizzo
- Department
of Chemistry, ‡Department of Biochemistry, §Mass Spectrometry Research Center, and ∥Departments
of Pharmacology and Medicine, Vanderbilt University, Nashville, Tennessee 37232, United States
| | - Boone M. Prentice
- Department
of Chemistry, ‡Department of Biochemistry, §Mass Spectrometry Research Center, and ∥Departments
of Pharmacology and Medicine, Vanderbilt University, Nashville, Tennessee 37232, United States
| | - Jessica L. Moore
- Department
of Chemistry, ‡Department of Biochemistry, §Mass Spectrometry Research Center, and ∥Departments
of Pharmacology and Medicine, Vanderbilt University, Nashville, Tennessee 37232, United States
| | - Jeremy L. Norris
- Department
of Chemistry, ‡Department of Biochemistry, §Mass Spectrometry Research Center, and ∥Departments
of Pharmacology and Medicine, Vanderbilt University, Nashville, Tennessee 37232, United States
| | - Richard M. Caprioli
- Department
of Chemistry, ‡Department of Biochemistry, §Mass Spectrometry Research Center, and ∥Departments
of Pharmacology and Medicine, Vanderbilt University, Nashville, Tennessee 37232, United States
| |
Collapse
|
31
|
Norris JL, Farrow MA, Gutierrez DB, Palmer LD, Muszynski N, Sherrod SD, Pino JC, Allen JL, Spraggins JM, Lubbock ALR, Jordan A, Burns W, Poland JC, Romer C, Manier ML, Nei YW, Prentice BM, Rose KL, Hill S, Van de Plas R, Tsui T, Braman NM, Keller MR, Rutherford SA, Lobdell N, Lopez CF, Lacy DB, McLean JA, Wikswo JP, Skaar EP, Caprioli RM. Integrated, High-Throughput, Multiomics Platform Enables Data-Driven Construction of Cellular Responses and Reveals Global Drug Mechanisms of Action. J Proteome Res 2017; 16:1364-1375. [PMID: 28088864 DOI: 10.1021/acs.jproteome.6b01004] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An understanding of how cells respond to perturbation is essential for biological applications; however, most approaches for profiling cellular response are limited in scope to pre-established targets. Global analysis of molecular mechanism will advance our understanding of the complex networks constituting cellular perturbation and lead to advancements in areas, such as infectious disease pathogenesis, developmental biology, pathophysiology, pharmacology, and toxicology. We have developed a high-throughput multiomics platform for comprehensive, de novo characterization of cellular mechanisms of action. Platform validation using cisplatin as a test compound demonstrates quantification of over 10 000 unique, significant molecular changes in less than 30 days. These data provide excellent coverage of known cisplatin-induced molecular changes and previously unrecognized insights into cisplatin resistance. This proof-of-principle study demonstrates the value of this platform as a resource to understand complex cellular responses in a high-throughput manner.
Collapse
Affiliation(s)
| | | | | | | | | | - Stacy D Sherrod
- Vanderbilt Institute of Chemical Biology, Vanderbilt University , Nashville, Tennessee 37232, United States
| | | | | | | | | | | | | | - James C Poland
- Vanderbilt Institute of Chemical Biology, Vanderbilt University , Nashville, Tennessee 37232, United States
| | | | | | | | | | | | | | - Raf Van de Plas
- Delft Center for Systems and Control, Delft University of Technology , Delft 2628 CD, The Netherlands
| | | | - Nathaniel M Braman
- Biomedical Engineering, Vanderbilt University School of Engineering , Nashville, Tennessee 37235, United States
| | - M Ray Keller
- Vanderbilt Institute of Chemical Biology, Vanderbilt University , Nashville, Tennessee 37232, United States
| | | | | | - Carlos F Lopez
- Biomedical Engineering, Vanderbilt University School of Engineering , Nashville, Tennessee 37235, United States
| | | | - John A McLean
- Vanderbilt Institute of Chemical Biology, Vanderbilt University , Nashville, Tennessee 37232, United States
| | - John P Wikswo
- Biomedical Engineering, Vanderbilt University School of Engineering , Nashville, Tennessee 37235, United States
| | | | | |
Collapse
|
32
|
Prentice BM, Chumbley CW, Caprioli RM. Absolute Quantification of Rifampicin by MALDI Imaging Mass Spectrometry Using Multiple TOF/TOF Events in a Single Laser Shot. J Am Soc Mass Spectrom 2017; 28:136-144. [PMID: 27655354 PMCID: PMC5177505 DOI: 10.1007/s13361-016-1501-2] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 08/31/2016] [Accepted: 09/02/2016] [Indexed: 05/13/2023]
Abstract
Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for the visualization of molecular distributions within tissue sections. While providing excellent molecular specificity and spatial information, absolute quantification by MALDI IMS remains challenging. Especially in the low molecular weight region of the spectrum, analysis is complicated by matrix interferences and ionization suppression. Though tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity and improve sensitivity by eliminating chemical noise, typical MALDI MS/MS modalities only scan for a single MS/MS event per laser shot. Herein, we describe TOF/TOF instrumentation that enables multiple fragmentation events to be performed in a single laser shot, allowing the intensity of the analyte to be referenced to the intensity of the internal standard in each laser shot while maintaining the benefits of MS/MS. This approach is illustrated by the quantitative analyses of rifampicin (RIF), an antibiotic used to treat tuberculosis, in pooled human plasma using rifapentine (RPT) as an internal standard. The results show greater than 4-fold improvements in relative standard deviation as well as improved coefficients of determination (R2) and accuracy (>93% quality controls, <9% relative errors). This technology is used as an imaging modality to measure absolute RIF concentrations in liver tissue from an animal dosed in vivo. Each microspot in the quantitative image measures the local RIF concentration in the tissue section, providing absolute pixel-to-pixel quantification from different tissue microenvironments. The average concentration determined by IMS is in agreement with the concentration determined by HPLC-MS/MS, showing a percent difference of 10.6%. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Boone M Prentice
- Department of Biochemistry, Vanderbilt University, 9160 MRB III, Nashville, TN, 37232, USA
- Mass Spectrometry Research Center, Nashville, TN, 37232, USA
| | - Chad W Chumbley
- Department of Chemistry, Nashville, TN, 37232, USA
- Mass Spectrometry Research Center, Nashville, TN, 37232, USA
| | - Richard M Caprioli
- Department of Biochemistry, Vanderbilt University, 9160 MRB III, Nashville, TN, 37232, USA.
- Department of Chemistry, Nashville, TN, 37232, USA.
- Departments of Pharmacology and Medicine, Nashville, TN, 37232, USA.
- Mass Spectrometry Research Center, Nashville, TN, 37232, USA.
| |
Collapse
|
33
|
Prentice BM, Chumbley CW, Hachey BC, Norris JL, Caprioli RM. Multiple Time-of-Flight/Time-of-Flight Events in a Single Laser Shot for Improved Matrix-Assisted Laser Desorption/Ionization Tandem Mass Spectrometry Quantification. Anal Chem 2016; 88:9780-9788. [PMID: 27573922 DOI: 10.1021/acs.analchem.6b02821] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Quantitative matrix-assisted laser desorption/ionization time-of-flight (MALDI TOF) approaches have historically suffered from poor accuracy and precision mainly due to the nonuniform distribution of matrix and analyte across the target surface, matrix interferences, and ionization suppression. Tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity as well as improve signal-to-noise ratios by eliminating interferences from chemical noise, alleviating some concerns about dynamic range. However, conventional MALDI TOF/TOF modalities typically only scan for a single MS/MS event per laser shot, and multiplex assays require sequential analyses. We describe here new methodology that allows for multiple TOF/TOF fragmentation events to be performed in a single laser shot. This technology allows the reference of analyte intensity to that of the internal standard in each laser shot, even when the analyte and internal standard are quite disparate in m/z, thereby improving quantification while maintaining chemical specificity and duty cycle. In the quantitative analysis of the drug enalapril in pooled human plasma with ramipril as an internal standard, a greater than 4-fold improvement in relative standard deviation (<10%) was observed as well as improved coefficients of determination (R2) and accuracy (>85% quality controls). Using this approach we have also performed simultaneous quantitative analysis of three drugs (promethazine, enalapril, and verapamil) using deuterated analogues of these drugs as internal standards.
Collapse
Affiliation(s)
- Boone M Prentice
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| | - Chad W Chumbley
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| | - Brian C Hachey
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| | - Jeremy L Norris
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| | - Richard M Caprioli
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| |
Collapse
|
34
|
Prentice BM, Chumbley CW, Caprioli RM. High-speed MALDI MS/MS imaging mass spectrometry using continuous raster sampling. J Mass Spectrom 2016; 51:665. [PMID: 28239976 DOI: 10.1002/jms.3798] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
|
35
|
Zubair F, Prentice BM, Norris JL, Laibinis PE, Caprioli RM. Standard Reticle Slide To Objectively Evaluate Spatial Resolution and Instrument Performance in Imaging Mass Spectrometry. Anal Chem 2016; 88:7302-11. [PMID: 27299987 DOI: 10.1021/acs.analchem.6b01655] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Spatial resolution is a key parameter in imaging mass spectrometry (IMS). Aside from being a primary determinant in overall image quality, spatial resolution has important consequences on the acquisition time of the IMS experiment and the resulting file size. Hardware and software modifications during instrumentation development can dramatically affect the spatial resolution achievable using a given imaging mass spectrometer. As such, an accurate and objective method to determine the working spatial resolution is needed to guide instrument development and ensure quality IMS results. We have used lithographic and self-assembly techniques to fabricate a pattern of crystal violet as a standard reticle slide for assessing spatial resolution in matrix-assisted laser desorption/ionization (MALDI) IMS experiments. The reticle is used to evaluate spatial resolution under user-defined instrumental conditions. Edgespread analysis measures the beam diameter for a Gaussian profile and line scans measure an "effective" spatial resolution that is a convolution of beam optics and sampling frequency. The patterned crystal violet reticle was also used to diagnose issues with IMS instrumentation such as intermittent losses of pixel data.
Collapse
Affiliation(s)
- Faizan Zubair
- National Research Resource for Imaging Mass Spectrometry, ‡Department of Chemical and Biomolecular Engineering, §Department of Biochemistry, and ∥Departments of Chemistry and Medicine, Vanderbilt University , Nashville, Tennessee, United States
| | - Boone M Prentice
- National Research Resource for Imaging Mass Spectrometry, ‡Department of Chemical and Biomolecular Engineering, §Department of Biochemistry, and ∥Departments of Chemistry and Medicine, Vanderbilt University , Nashville, Tennessee, United States
| | - Jeremy L Norris
- National Research Resource for Imaging Mass Spectrometry, ‡Department of Chemical and Biomolecular Engineering, §Department of Biochemistry, and ∥Departments of Chemistry and Medicine, Vanderbilt University , Nashville, Tennessee, United States
| | - Paul E Laibinis
- National Research Resource for Imaging Mass Spectrometry, ‡Department of Chemical and Biomolecular Engineering, §Department of Biochemistry, and ∥Departments of Chemistry and Medicine, Vanderbilt University , Nashville, Tennessee, United States
| | - Richard M Caprioli
- National Research Resource for Imaging Mass Spectrometry, ‡Department of Chemical and Biomolecular Engineering, §Department of Biochemistry, and ∥Departments of Chemistry and Medicine, Vanderbilt University , Nashville, Tennessee, United States
| |
Collapse
|
36
|
Bu J, Fisher CM, Gilbert JD, Prentice BM, McLuckey SA. Selective Covalent Chemistry via Gas-Phase Ion/ion Reactions: An Exploration of the Energy Surfaces Associated with N-Hydroxysuccinimide Ester Reagents and Primary Amines and Guanidine Groups. J Am Soc Mass Spectrom 2016; 27:1089-1098. [PMID: 27020926 DOI: 10.1007/s13361-016-1359-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Revised: 01/28/2016] [Accepted: 01/30/2016] [Indexed: 06/05/2023]
Abstract
Selective covalent bond forming reactions (referred to as covalent reactions) can occur in gas-phase ion/ion reactions and take place via the formation of a long-lived chemical complex. The gas-phase ion/ion reactivity between sulfo-N-hydroxysuccinimide (sulfo-NHS) ester reagent anions and peptide cations containing a primary amine or guanidine group has been examined via DFT calculations and complex dissociation rate measurements. The results reveal insights regarding the roles of the barriers of competing processes within the complex. When the covalent reaction is exothermic, two prototypical cases, determined by the nature of the energy surface, are apparent. The product partitioning between covalent reaction and simple proton transfer upon dissociation of the long-lived complex is sensitive to activation conditions when the transition state barrier for covalent reaction is relatively high (case 1) but is insensitive to activation conditions when the transition state barrier is relatively low (case 2). Covalent reaction efficiencies are very high in case 2 scenarios, such as when the reactive site is a guanidine and the anion attachment site is a guanidinium ion. Covalent reaction efficiencies are variable, and generally low, in case 1 scenarios, such as when an amine is the reactive site and an ammonium ion is the site of anion attachment. A relatively long slow-heating step prior to the complex dissociation step, however, can dramatically increase covalent reaction yield in case 1 scenarios. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Jiexun Bu
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA
| | - Christine M Fisher
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA
| | - Joshua D Gilbert
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA
| | - Boone M Prentice
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA
| | - Scott A McLuckey
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA.
| |
Collapse
|
37
|
|
38
|
Prentice BM, Caprioli RM. The Need for Speed in Matrix-Assisted Laser Desorption/Ionization Imaging Mass Spectrometry. Postdoc J 2016; 4:3-13. [PMID: 27570788 PMCID: PMC4996283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Imaging mass spectrometry (IMS) has emerged as a powerful analytical tool enabling the direct molecular mapping of many types of tissue. Specifically, matrix-assisted laser desorption/ ionization (MALDI) represents one of the most broadly applicable IMS technologies. In recent years, advances in solid state laser technology, mass spectrometry instrumentation, computer technology, and experimental methodology have produced IMS systems capable of unprecedented data acquisition speeds (>50 pixels/second). In applications of this technology, throughput is an important consideration when designing an IMS experiment. As IMS becomes more widely adopted, continual improvements in experimental setups will be important to address biologically and clinically relevant time scales.
Collapse
Affiliation(s)
- Boone M. Prentice
- Department of Biochemistry Vanderbilt University, Nashville, TN 37232
- Department of Mass Spectrometry Research Center Vanderbilt University, Nashville, TN 37232
| | - Richard M. Caprioli
- Department of Biochemistry Vanderbilt University, Nashville, TN 37232
- Department of Chemistry Vanderbilt University, Nashville, TN 37232
- Department of Pharmacology and Medicine Vanderbilt University, Nashville, TN 37232
- Department of Mass Spectrometry Research Center Vanderbilt University, Nashville, TN 37232
| |
Collapse
|
39
|
Forrest WP, Choudhuri MMR, Kilyanek SM, Natoli SN, Prentice BM, Fanwick PE, Crutchley RJ, Ren T. Synthesis and Electronic Structure of Ru2(Xap)4(Y-gem-DEE) Type Compounds: Effect of Cross-Conjugation. Inorg Chem 2015. [PMID: 26204103 DOI: 10.1021/acs.inorgchem.5b01315] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Reported in this Article are the preparation and characterization of a series of new Ru2(II,III) compounds bearing one cross-conjugated σ-geminal-diethynylethene ligand (gem-DEE), namely, Ru2(Xap)4(Y-gem-DEE) (Xap = N,N'-anilinopyridinate (ap) or 2-(3,5-dimethoxy)anilinopyridinate (DiMeOap), and Y = Si(i)Pr3 (1) or H (2)) and [Ru2(ap)4]2(μ-gem-DEE) (3). Compounds 1-3 were characterized by spectroscopic and voltammetric techniques as well as the single crystal X-ray diffraction study of 2a. The X-ray structural data of 2a and the spectroscopic/voltammetric data of compounds 1 and 2 indicate that the gem-DEE ligands are similar to simple alkynyls in their effects on the molecular and electronic structures of the Ru2(Xap)4 moiety. Similar to the previously studied [Ru2(ap)4]2(μ-C2n) type compounds, dimer 3 exhibits pairwise 1e(-) oxidations and reductions, albeit the potential splits within the pair (ΔE1/2) are significantly smaller than those of [Ru2(ap)4]2(μ-C4). The electronic absorption spectra of the reduced and oxidized derivatives of 1a and 3 were determined using spectroelectrochemistry methods. No discernible intervalence charge transfer transition (IVCT) was detected in the near-IR spectrum for either 3(-) or 3(+), suggesting that the Ru2-Ru2 coupling in these mixed-valence states is weak. DFT calculations on a model compound of 3 yielded six singly occupied molecular orbitals (SOMOs), which have Ru2 contributions similar to those previously calculated for the [Ru2(ap)4]2(μ-C2n) type compounds. Among six SOMOs, SOMO-2 is the only one containing substantial dπ-π(gem-DEE) character across the entire Ru2-μ-gem-DEE-Ru2 linkage, which explains the weakened Ru2-Ru2 coupling.
Collapse
Affiliation(s)
- William P Forrest
- †Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | | | - Stefan M Kilyanek
- §Department of Chemistry and Biochemistry, University of Arkansas, Fayettesville, Arkansas 72701, United States
| | - Sean N Natoli
- †Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Boone M Prentice
- †Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Phillip E Fanwick
- †Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Robert J Crutchley
- ‡Department of Chemistry, Carleton University, Ottawa, Ontario K1S 5B6, Canada
| | - Tong Ren
- †Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
40
|
Gilbert JD, Prentice BM, McLuckey SA. Ion/ion reactions with "onium" reagents: an approach for the gas-phase transfer of organic cations to multiply-charged anions. J Am Soc Mass Spectrom 2015; 26:818-25. [PMID: 25652935 PMCID: PMC4654941 DOI: 10.1007/s13361-015-1077-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Revised: 12/27/2014] [Accepted: 01/08/2015] [Indexed: 05/13/2023]
Abstract
The use of ion/ion reactions to effect gas-phase alkylation is demonstrated. Commonly used fixed-charge "onium" cations are well-suited for ion/ion reactions with multiply deprotonated analytes because of their tendency to form long-lived electrostatic complexes. Activation of these complexes results in an SN2 reaction that yields an alkylated anion with the loss of a neutral remnant of the reagent. This alkylation process forms the basis of a general method for alkylation of deprotonated analytes generated via electrospray, and is demonstrated on a variety of anionic sites. SN2 reactions of this nature are demonstrated empirically and characterized using density functional theory (DFT). This method for modification in the gas phase is extended to the transfer of larger and more complex R groups that can be used in later gas-phase synthesis steps. For example, N-cyclohexyl-N'-(2-morpholinoethyl)carbodiimide (CMC) is used to transfer a carbodiimide functionality to a peptide anion containing a carboxylic acid. Subsequent activation yields a selective reaction between the transferred carbodiimide group and a carboxylic acid, suggesting the carbodiimide functionality is retained through the transfer process. Many different R groups are transferable using this method, allowing for new possibilities for charge manipulation and derivatization in the gas phase.
Collapse
Affiliation(s)
- Joshua D Gilbert
- Department of Chemistry, Purdue University, West Lafayette, IN, 4907-2084, USA
| | | | | |
Collapse
|
41
|
Prentice BM, Chumbley CW, Caprioli RM. High-speed MALDI MS/MS imaging mass spectrometry using continuous raster sampling. J Mass Spectrom 2015; 50:703-10. [PMID: 26149115 PMCID: PMC4498415 DOI: 10.1002/jms.3579] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Revised: 01/30/2015] [Accepted: 02/09/2015] [Indexed: 05/03/2023]
Abstract
A matrix-assisted laser desorption/ionization time of flight/time of flight tandem mass spectrometer (MALDI TOF/TOF) has been used for high-speed precursor/fragment ion transition image acquisition. High-throughput analysis is facilitated by an Nd:YLF solid state laser capable of pulse repetition rates up to 5 kHz, a high digitizer acquisition rate (up to 50 pixels/s), and continuous laser raster sampling. MS/MS experiments are enabled through the use of a precision timed ion selector, second source acceleration, and a dedicated collision cell. Continuous raster sampling is shown here to facilitate rapid MS/MS ion image acquisition from thin tissue sections for the drug rifampicin and for a common kidney lipid, SM4s(d18:1/24:1). The ability to confirm the structural identity of an analyte as part of the MS/MS imaging experiment is an essential part of the analysis. Additionally, the increase in sensitivity and specificity afforded by an MS/MS approach is highly advantageous, especially when interrogating complex chemical environments such as those in biological tissues. Herein, we report continuous laser raster sampling TOF/TOF imaging methodologies which demonstrate 8 to 14-fold increases in throughput compared with existing MS/MS instrumentation, an important advantage when imaging large areas on tissues.
Collapse
Affiliation(s)
- Boone M. Prentice
- Department of Biochemistry, Nashville, TN 37232
- Mass Spectrometry Research Center, Nashville, TN 37232
| | - Chad W. Chumbley
- Department of Chemistry, Nashville, TN 37232
- Mass Spectrometry Research Center, Nashville, TN 37232
| | - Richard M. Caprioli
- Department of Biochemistry, Nashville, TN 37232
- Department of Chemistry, Nashville, TN 37232
- Departments of Pharmacology and Medicine, Nashville, TN 37232
- Mass Spectrometry Research Center, Nashville, TN 37232
- Address correspondence to: Dr. R. M. Caprioli, 9160 MRB III, Department of Biochemistry, Vanderbilt University, Nashville, TN 37232, USA, Phone: (615) 322-4336, Fax: (615) 343-8372,
| |
Collapse
|
42
|
Luongo CA, Bu J, Burke NL, Gilbert JD, Prentice BM, Cummings S, Reed CA, McLuckey SA. Selective removal of alkali metal cations from multiply-charged ions via gas-phase ion/ion reactions using weakly coordinating anions. J Am Soc Mass Spectrom 2015; 26:404-414. [PMID: 25560986 DOI: 10.1007/s13361-014-1052-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 11/14/2014] [Accepted: 11/15/2014] [Indexed: 06/04/2023]
Abstract
Selective removal of alkali metal cations from mixed cation multiply-charged peptide ions is demonstrated here using gas-phase ion/ion reactions with a series of weakly coordinating anions (WCAs), including hexafluorophosphate (PF6 (-)), tetrakis[3,5-bis(trifluoromethyl)phenyl]borate (BARF), tetrakis(pentafluorophenyl)borate (TPPB), and carborane (CHB11Cl11 (-)). In all cases, a long-lived complex is generated by dication/anion condensation followed by ion activation to compare proton transfer with alkali ion transfer from the peptide to the anion. The carborane anion was the only anion studied to undergo dissociation exclusively through loss of the metallated anion, regardless of the studied metal adduct. All other anions studied yield varying abundances of protonated and metallated peptide depending on the peptide sequence and the metal identity. Density functional theory calculations suggest that for the WCAs studied, metal ion transfer is most strongly favored thermodynamically, which is consistent with the experimental results. The carborane anion is demonstrated to be a robust reagent for the selective removal of alkali metal cations from peptide cations with mixtures of excess protons and metal cations.
Collapse
Affiliation(s)
- Carl A Luongo
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Gilbert JD, Fisher CM, Bu J, Prentice BM, Redwine JG, McLuckey SA. Strategies for generating peptide radical cations via ion/ion reactions. J Mass Spectrom 2015; 50:418-26. [PMID: 25800024 PMCID: PMC4372815 DOI: 10.1002/jms.3548] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2014] [Revised: 11/14/2014] [Accepted: 11/16/2014] [Indexed: 05/25/2023]
Abstract
Several approaches for the generation of peptide radical cations using ion/ion reactions coupled with either collision induced dissociation (CID) or ultraviolet photo dissociation (UVPD) are described here. Ion/ion reactions are used to generate electrostatic or covalent complexes comprised of a peptide and a radical reagent. The radical site of the reagent can be generated multiple ways. Reagents containing a carbon-iodine (C-I) bond are subjected to UVPD with 266-nm photons, which selectively cleaves the C-I bond homolytically. Alternatively, reagents containing azo functionalities are collisionally activated to yield radical sites on either side of the azo group. Both of these methods generate an initial radical site on the reagent, which then abstracts a hydrogen from the peptide while the peptide and reagent are held together by either electrostatic interactions or a covalent linkage. These methods are demonstrated via ion/ion reactions between the model peptide RARARAA (doubly protonated) and various distonic anionic radical reagents. The radical site abstracts a hydrogen atom from the peptide, while the charge site abstracts a proton. The net result is the conversion of a doubly protonated peptide to a peptide radical cation. The peptide radical cations have been fragmented via CID and the resulting product ion mass spectra are compared to the control CID spectrum of the singly protonated, even-electron species. This work is then extended to bradykinin, a more broadly studied peptide, for comparison with other radical peptide generation methods. The work presented here provides novel methods for generating peptide radical cations in the gas phase through ion/ion reaction complexes that do not require modification of the peptide in solution or generation of non-covalent complexes in the electrospray process.
Collapse
Affiliation(s)
| | | | | | | | | | - Scott A. McLuckey
- Address reprint requests to: Dr. S. A. McLuckey 560 Oval Drive Department of Chemistry Purdue University West Lafayette, IN 47907-2084, USA Phone: (765) 494-5270 Fax: (765) 494-0239
| |
Collapse
|
44
|
Prentice BM, McGee WM, Stutzman JR, McLuckey SA. Strategies for the Gas Phase Modification of Cationized Arginine via Ion/ion Reactions. Int J Mass Spectrom 2013; 354-355:10.1016/j.ijms.2013.05.026. [PMID: 24273437 PMCID: PMC3835304 DOI: 10.1016/j.ijms.2013.05.026] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The gas phase acetylation of cationized arginine residues is demonstrated here using ion/ion reactions with sulfosuccinimidyl acetate (sulfo-NHS acetate) anions. Previous reports have demonstrated the gas phase modification of uncharged primary amine (the N-terminus and ε-amino side chain of lysine) and uncharged guanidine (the arginine side chain) functionalities via sulfo-NHS ester chemistry. Herein, charge-saturated arginine-containing peptides that contain sodium ions as the charge carriers, such as [ac-ARAAARA+2Na]2+, are shown to exhibit strong reactivity towards sulfo-NHS acetate whereas the protonated peptide analogues exhibit no such reactivity. This difference in reactivity is attributed to the lower sodium ion (as compared to proton) affinity of the arginine, which results in increased nucleophilicity of the cationized arginine guanidinium functionality. This increased nucleophilicity improves the arginine residue's reactivity towards sulfo-NHS esters and enhances the gas phase covalent modification pathway. No such dramatic increase in reactivity towards sulfo-NHS acetate has been observed upon sodium cationization of lysine amino acid residues, indicating that this behavior appears to be unique to arginine. The sodium cationization process is demonstrated in the condensed phase by simply spiking sodium chloride into the peptide sample solution and in the gas phase by a peptide-sodium cation exchange process with a sulfo-NHS acetate sodium-bound dimer cluster reagent. This methodology demonstrates several ways by which arginine can be covalently modified in the gas phase even when it is charged. Collisional activation of an acetylated arginine product can result in deguanidination of the residue, generating an ornithine. This gas phase ornithination exhibits similar site-specific fragmentation behavior to that observed with peptides ornithinated in solution and may represent a useful approach for inducing selective peptide cleavages.
Collapse
Affiliation(s)
| | | | | | - Scott A. McLuckey
- Address reprint requests to: Dr. S. A. McLuckey 560 Oval Drive Department of Chemistry Purdue University West Lafayette, IN 47907-2084, USA Phone: (765) 494-5270 Fax: (765) 494-0239
| |
Collapse
|
45
|
Savchenko J, Cao Z, Natoli SN, Cummings SP, Prentice BM, Fanwick PE, Ren T. New Diruthenium Bis-alkynyl Compounds as Potential Ditopic Linkers. Organometallics 2013. [DOI: 10.1021/om400799c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Julia Savchenko
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Zhi Cao
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Sean N. Natoli
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Steven P. Cummings
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Boone M. Prentice
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Phillip E. Fanwick
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Tong Ren
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
46
|
Prentice BM, Stutzman JR, McLuckey SA. Reagent cluster anions for multiple gas-phase covalent modifications of peptide and protein cations. J Am Soc Mass Spectrom 2013; 24:1045-52. [PMID: 23702708 PMCID: PMC3715118 DOI: 10.1007/s13361-013-0637-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2013] [Revised: 03/29/2013] [Accepted: 04/02/2013] [Indexed: 05/13/2023]
Abstract
Multiple gas phase ion/ion covalent modifications of peptide and protein ions are demonstrated using cluster-type reagent anions of N-hydroxysulfosuccinimide acetate (sulfo-NHS acetate) and 2-formyl-benzenesulfonic acid (FBMSA). These reagents are used to selectively modify unprotonated primary amine functionalities of peptides and proteins. Multiple reactive reagent molecules can be present in a single cluster ion, which allows for multiple covalent modifications to be achieved in a single ion/ion encounter and at the 'cost' of only a single analyte charge. Multiple derivatizations are demonstrated when the number of available reactive sites on the analyte cation exceeds the number of reagent molecules in the anionic cluster (e.g., data shown here for reactions between the polypeptide [K10 + 3H](3+) and the reagent cluster [5R(5Na) - Na](-)). This type of gas-phase ion chemistry is also applicable to whole protein ions. Here, ubiquitin was successfully modified using an FBMSA cluster anion which, upon collisional activation, produced fragment ions with various numbers of modifications. Data for the pentamer cluster are included as illustrative of the results obtained for the clusters comprised of two to six reagent molecules.
Collapse
Affiliation(s)
| | | | - Scott A. McLuckey
- Address reprint requests to: Dr. S. A. McLuckey, 560 Oval Drive, Department of Chemistry, Purdue University, West Lafayette, IN 47907-2084, USA, Phone: (765) 494-5270, Fax: (765) 494-0239,
| |
Collapse
|
47
|
Abstract
Gas-phase ion/ion reactions are emerging as useful and flexible means for the manipulation and characterization of peptide and protein biopolymers. Acid/base-like chemical reactions (i.e., proton transfer reactions) and reduction/oxidation (redox) reactions (i.e., electron transfer reactions) represent relatively mature classes of gas-phase chemical reactions. Even so, especially in regards to redox chemistry, the widespread utility of these two types of chemistries is undergoing rapid growth and development. Additionally, a relatively new class of gas-phase ion/ion transformations is emerging which involves the selective formation of functional-group-specific covalent bonds. This feature details our current work and perspective on the developments and current capabilities of these three areas of ion/ion chemistry with an eye towards possible future directions of the field.
Collapse
Affiliation(s)
- Boone M. Prentice
- Purdue University – Department of Chemistry, 560 Oval Drive, West Lafayette, IN, 47907-2084, USA
| | - Scott A. McLuckey
- Purdue University – Department of Chemistry, 560 Oval Drive, West Lafayette, IN, 47907-2084, USA
| |
Collapse
|
48
|
Prentice BM, Gilbert JD, Stutzman JR, Forrest WP, McLuckey SA. Gas-phase reactivity of carboxylic acid functional groups with carbodiimides. J Am Soc Mass Spectrom 2013. [PMID: 23208744 PMCID: PMC3554847 DOI: 10.1007/s13361-012-0506-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Gas-phase modification of carboxylic acid functionalities is performed via ion/ion reactions with carbodiimide reagents [N-cyclohexyl-N'-(2-morpholinoethyl)carbodiimide (CMC) and [3-(3-Ethylcarbodiimide-1-yl)propyl]trimethylaminium (ECPT)]. Gas-phase ion/ion covalent chemistry requires the formation of a long-lived complex. In this instance, the complex is stabilized by an electrostatic interaction between the fixed charge quaternary ammonium group of the carbodiimide reagent cation and the analyte dianion. Subsequent activation results in characteristic loss of an isocyanate derivative from one side of the carbodiimide functionality, a signature for this covalent chemistry. The resulting amide bond is formed on the analyte at the site of the original carboxylic acid. Reactions involving analytes that do not contain available carboxylic acid groups (e.g., they have been converted to sodium salts) or reagents that do not have the carbodiimide functionality do not undergo a covalent reaction. This chemistry is demonstrated using PAMAM generation 0.5 dendrimer, ethylenediaminetetraacetic acid (EDTA), and the model peptide DGAILDGAILD. This work demonstrates the selective gas-phase covalent modification of carboxylic acid functionalities.
Collapse
Affiliation(s)
| | | | | | | | - Scott A. McLuckey
- Address reprint requests to: Dr. S. A. McLuckey, 560 Oval Drive, Department of Chemistry, Purdue University, West Lafayette, IN 47907-2084, USA, Phone: (765) 494-5270, Fax: (765) 494-0239,
| |
Collapse
|
49
|
Forrest WP, Cao Z, Hambrick HR, Prentice BM, Fanwick PE, Wagenknecht PS, Ren T. Photoactive Chromium(III)-Cyclam Complexes with Axially Boundgeminal-Diethynylethenes. Eur J Inorg Chem 2012. [DOI: 10.1002/ejic.201201235] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
50
|
Prentice BM, McLuckey SA. Analysis of High Mass-to-Charge Ions in a Quadrupole Ion Trap Mass Spectrometer via an End-Cap Quadrupolar Direct Current Downscan. Anal Chem 2012; 84:7562-9. [PMID: 22881346 DOI: 10.1021/ac301741a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Boone M. Prentice
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907-2084,
United States
| | - Scott A. McLuckey
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907-2084,
United States
| |
Collapse
|